Loading...
Correspondence V (Ati 447A December 1, 1995 CITY OF TIGARD OREGON Janette Henman NW Landscape Ind. 16075 SW Upper Boones Ferry Road Tigard, OR 97224 Re: MODULAR UNITS 16075 SW Upper Boones Ferry Road PC4 -50C BUP95 -0155 As the new plans examiner, I have inherited your application. After reviewing the material you submitted on November 21, 1995, I find the following requirements of our May 15, 1995 plan review letter have not been addressed. l/7% Item #1. 2/. Item #3. Provide specifications. 2/ Item #4. Provide a detail of edge protection for the ramp and guardrail specifications for deck, ramp, and stairways that are 30" / or more above ground level. 4. Item #6. Obtain, complete, and submit applications for permits for each of the modular units. 5 . Item #8. Provide a drawing detail of the accessible restroom access route and of the restrooms. Show dimensions, fixture locations, and height above finish floor. /'• Item #9. Item #11. Provide a site plan showing final layout, dimensions, accessible route from the public way to the accessible entrance of each unit. Please provide three (3) copies of the revised plans with all requirements noted. If you wish to discuss any of these items, please give me a call. Sincerely, James Funk Plans Examiner bup95- 0155 \pc4 -50c 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 • October 1, 1998 umedip, u ��V °' ,� r\ �I� CITY OF TIGARD Richard Akerman 16075 SW Upper Boones Ferry Road OREGON Tigard, OR 97224 Re: Permit # BUP95 -0155 at 16075 Upper Boones Ferry Road/ 2S 113AB Tax Lot: 300 Dear Mr. Akerman, It has come to our attention that permit # BUP95 -0155 has not passed the Final Inspection. This permit was issued for the placement of three modular office buildings, a deck, and a ramp. A correction notice was issued on June 9, 1998. Please complete the corrections from the June 9, 1998 inspection and schedule a final inspection within 30 days. If you have any questions concerning this permit, please feel free to contact me at (503) 639 -4171 x414. Sincerely, Wa/1/15/A. Warren Jackson Building Inspector C: Darrell Watkins, Inspection Supervisor • Pitt 13125.SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 : °95- ov i 55 i , , -4.4 CITY OF TIGARD May 15, 1995 OREGON Akerman & Wathey, Inc. DBA Northwest Landscape Industries 16075 S.W. Upper Boones Ferry Road Tigard, OR 97224 Project: Modular Units - Plan Check #4 -50C 16075 SW Upper Boones Ferry Road, Tigard, Oregon Subject: Building Plan Review (1991 UBC with Oregon Amendments) 1 � The plans for this project were reviewed for conformity with ✓ applicable codes. The following comments are noted: V n� �1 All building materials including structural supports of �LLL//// decking shall be of pressure treated materials or wood of 4 natural resistance to decay. (Section 2516). The maximum slope of the ramp shall not be steeper than 1:12. (Section 3109(9)2). lap non -skid surface shall be applied to the ramp. (Section 3109(9)7) . • 4 . Handrails shall be provided along the ramp between 34 and 38 inches above the ramp surfaces. Such handrails shall extend not less than 12• beyond the top and bottom of the ramp. 1( (Section 3306 & 3109). The double -cross beams shall be not less than 2 X 6 members. A permit is required for each modular unit. Modular setup requirements are addressed in Section 5005. Provide the following for each unit: • Valuation • Floor Plan . A paved accessible parking space must be provided with an accessible paved path of travel to the ramp. __ An accessible sanitary facility must be provided. If accessible facility is in existing building, then there must be an accessible path of travel from units to that sanitary facility. 9. Units must be anchored to resist lateral loads. Provide engineered anchorage details. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Akerman & Wathey, Inc. Page 2 May 15, 1995 The units must bear an insignia of inspection approval from the State of Oregon. h.► Provide 1 revised site plan showing location of units and addressing items 7 and 8 above. Please submit 3 sets of revised plans for review. Further comments may follow. Since - y, • David Scott, P.E. Building Official DS:js PRMSYSWOCUMENT\BUP95 01.55\PC#450C.DOC 1 1 ■ • Cii.111 7 LANDSCAPE 1 . 1 March 11, 1996 James Funk, Plans Examiner City of Tigard 13125 SW Hall Blvd. Tigard, OR 97224 RE: Modular Units PC4 -50C BUP95 -0155 We apologize for the delay in getting this response to you. In regards to your letter dated December 1, 1995, I will address your questions by number. 1 Item #1: All building materials, including structural supports used in the construction of the deck, were of pressure treated wood and materials resistant to decay. Item #3: In accordance with Section 3109, we affixed a non -skid sandpaper surface to the entire ramp. 3! Item #4: Edge protection for the ramp is a wooden strip, 1" X 1 ". Guardrail /handrail height is 36" above the ramp and deck as well as all stairways. I4. Item #6: Modular units were placed and anchored by Modern Building Systems. The only contractor's involved were Willamette Electric and Phoenix Electric. No plumbing or building construction involved. The electrical contractors obtained their own permits for this work. Attached are permit / applications for each of the modular units. 65 Item #8: Drawing of restroom showing location of fixtures, placement and height of bar from floor and drawing of restroom �� access route and location of restroom in building are attached. 11e• Item #9: Engineered anchorage details are included with report from Froelich Consulting Engineers and Modern Building Systems. Modern Building Systems placed and anchored each of the trailers. Item #11: A site plan showing final layout, dimensions, accessible route from the public way to the accessible entrance of each unit is attached. Three copies of the revised plans with all requirements noted are attached. If there are any questions, or if you need anything else, please do not hesitate to call me. Sincerely, ,jl r / Fanette Henman dministrataive Assistant JH/ Enclosures 16075 S.W. UPPER BOONES FERRY RD., TIGARD, OR 97224 (503) 684 -1450 FAX (503) 620 -7592 ® Printed on Recycled Paper