Specifications
RECEIVED DELTZ\ AUG 31 2007 C ITY OF TIGARD 14795 S.W. 7213VarnIV DIV1SION FIR I N C 503 -62 - 0 20 • 6 OR03 97224 -620 -1058 oo 9& 5 /60 ;37 £1't �` . " a. 3 Fanno Creek Buildin g "A" Suite 300 DATA SUBMITTAL FOR FIRE PROTECTION SYSTEM DELTA FIRE, INC. August 31, 2007 Michael Stewart 06 -3534 FIRE PROTECTION CONTRACTORS Fanno Creek Building "A" — Suite 100 August 31, 2007 Page 2 of 2 TABLE OF CONTENTS Pipe & Fittings Allied -Black DynaFlow Allied Black DynaThread Allied Black Sch. 10 Galv. CIS Fittings Victaulic Firelock Couplings Fig. #005 Victaulic Couplings Fig. #75 Victaulic Concentric Reducers #50 Hangers Pipe Rings Fig. #2 Tolco EQ Clamp Fig. # 4A Tolco Retainer Strap Fig. #69 Grinnell Top Beam Clamp Fig. # 92 Tolco Swivel Sway Brace Fig. # 910 Red Head Tru -Bolt (Para -bolt) Hilti Drop in Anchor Fig. #HDI Sammy XP Flex head Sprinkler Heads Reliable Model F1/FR''A" 155 Degree Pendent Reliable Model G/FR Quick Response 'A" 155 Degree Upright Sprinkler Valves Victaulic Butterfly Valve Fig. #705 -W Victaulic Firelock Check Valve Fig. #717 Victaulic Firelock Valve fig #727 Watts Ball Valves Switches & Bells Potter Flow Switch Fig. # VSR -F Potter Electronic Bell with Backing Box FIRE PROTECTION CONTRACTORS ®MO1 I -VN Aa _ .. ,...e.... =..er.,rellrell , = , I: t i ' 4 �y, j /. — r NI i , • ' i ,,, - • ,r1 • : , t ..... ; 1 1 l ti t3 • p 0 0 �� • + ;' ! j; 3n I 's i � ' _ s> iV I: i• ' p I 0 ' .....'. ,v4„,..., ,,,,„,:t.....41,44.:ti , . , , i .1.,.., , , ,,,s , . . . „„ , .,1:,,...t.,....,....,, ...,,,,,, .„:::,::....,..,..,§,41.:::,,,:::,,,,, , ,. I. ..k._ , ..41. ,,r ,• .:4:' ,( AIN ; .4 .,-- ;41: - ; , ' '' ' —, ' , ) ..-N ' l • : .; • x , fu . - ; I O! HIZ Y • � ti y . � .+� + � ',' . � _ °°, t F . k Tp� 1'J& ''4 . t��"� _ . > ' ' ' € '' ..� N ei➢t ., �..x a. +e "eh 3.` , • Dyna-Fiow® ,... High Strength Steel Pipe The original high- strength lightwall sprinkler pipe with hydraulics superior to Schedule -10. Dyna -Flow pipe is the "original" high - strength lightwall sprinkler pipe. Dyna- Specifications Flow has outstanding hydraulic NPS Nominal I.D. WI. WI. (H20 Filled) Pcs/ WI/Lift (21') Wt/Lift (24') Wtllift (25') capabilities and is recognized as the In; mm In; mm Lbs/Ft, Kg/m Lbs/Ft Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg most popular alternative to Schedule -10 1' 1.191 0.830 1.31 91 1,586 1,812 1,888 pipe. Lightweight, easy to cut and easy 25 30.3 1.2 1.95 91 719 822 856 to handle for installation. Dyna -Flow is a 1W 1.536 1.059 1.87 61 1,356 1,550 1,615 valuable addition to any fire protection 32 39.0 1.6 2.78 61 615 703 733 system. 1W 1.728 1.667 2.71 61 2,135 2,440 2,542 Superior Hydraulics 40 43.9 2.5 4.03 61 968 1107 1153 2' 2.203 2.104 3.79 37 1,634 1,868 1,946 With an inside diameter of up to 11% 50 56.0 3.1 5.64 37 741 847 883 larger than Schedule -40 and up to 7% 2W 2.703 2.564 5.10 30 1,615 1,846 1,923 larger than Schedule -10, Dyna -Flow 65 68.7 3.8 7.59 30 733 837 872 pipe hydraulics are exceptional. Larger 3' 3.314 3.387 7.18 19 1,351 1,544 1,608 I.D.s enable Dyna -Flow, and related 80 84.2 5.0 10.69 19 613 700 729 components, to be down -sized within the 4• 4.310 4.473 10.86 19 1,784 2,039 2,124 system, thus increasing the potential for 90 109.5 6.7 16.16 19 809 925 963 job cost savings. For complete Hazen - Williams charts, refer to "Dyna -Flow Hydraulic Data Tables." Coatings & Fabrication Specifications & Approvals Additional Benefits Dyna -Flow products are coated with Dyna -Flow /Super Flo pipe is manufac- • Lightweight and easy to install, an environmentally approved and tured to meet ASTM A -795 Type E, resulting in more efficient use of your specially formulated modified - acrylic or Grade A and is in compliance with freight and labor dollars. water -based coating. This durable coating NFPA -13 and NFPA -14. All sizes of is paintable. The black coating acts as Dyna Flow /Super Flo are UL Listed, FM • Provides stability needed to comply an excellent primer and is resistant to Approved and ULC Listed. with standard hanger spacing weathering and U.V. degradation from (15 ft O.C.) per NFPA. outdoor storage. ® ® ® • Available in Standard lengths for your Metallurgical properties provide excellent Listed Approved Listed convenience, or can be ordered in fabrication characteristics for end prep Dyna- Flow /Super Flo is UL/ULC Listed custom lengths upon approval. finishes, welding and roll grooving. for use with roll grooved, plain -end • Fast cutting and welding, as well as There is no special process or equipment couplings, and welded joints for wet, easy roll needed for fabrication and installation. 1 ,dry, Y grooving and end preparation. preaction and deluge systems. It is FM The internal surface of all black Allied Approved for roll grooved, plain -end, and • Available in Factory roll grooved form Tube & Conduit Fire Sprinkler pipe welded joints for wet systems. Refer to for quicker shop turnaround. products up to 4.5000" in diameter is appropriate documentation for up -to -date • Clean, durable mill coating provides coated with our new Antibacterial listing and approval information. Dyna- longer "shelf life" and acts as an Formula, "ABF ". In scientific laboratory Flow /Super Flo is now available "hot- excellent primer for custom paint test, ABS proved to have superior dip" galvanized and has been specifically applications. resistance to microbial colonization of approved by FM for dry systems uses. - pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. VICOI Flow Control II �.I 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 7 allied 11350 Norcom Rd. •Philadelphia, PA 19154 (800) 882 -5543 TUBE s CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708 - 339 -1806 S2 -3 i- I h .4 s 0 x k x $ . m O . _ fq : g I 12 ,,.....,. ....,.., „ .., ,, , . ,..,....4,7„.„*.v,„,...., ,. N Q NAQ IC , ‘, ..' :,,, :„.,;,.: li, i; =, t! A bN A Q 0 ,,. .. . .:„..,,...3,.„4,..„.. ` ,., 4 OY 7 III Jlflll IZ � NAC i�nr a nr �r �. - WN a ,VNAn i . �- , C hit , ° '- P t , F ill « :,, 3' F( -.- .. av111"1` ,_ S OY]!1'b1Y 01 NAa C.1 he' ' k b►NA t/NAO ,V NA VNAQ t c , : u ' a ; a �� 111: ., 2 r ; a zrva�tN _ _t�v"31NilL dv _ 7v�11 - UV9NN1 ;aq� *.9 • VNAd y /� y N�� . �N y /� yb'NA 1, �, , - ; 0.r � QTR �V NA,V � Y .V M , NA .a' . � �„ is `�`R _.. - _ . -. ___. • b,q T � r , i : Hi.- . _. OVJel lil.. _ 0Y:17Y1 f :_� 'x 1ffVA(I b� NA" 1 AQ yl� �� s �___�_ _ . r J , � i , if• c , s �,. c . Dyna-Thread Full Line Sch -40 Replacement Dyna - Thread' offers the life expectancy of Sch4O with superior hydraulics and greater value. Dyna - Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedules 40 Comparison to L.W.T. Pipes • Dyna- Thread's inside diameter is up • With its increased strength and lighter • More wall thickness at the thread to 3.6% larger than Sch-40 giving it weight, Dyna - Thread reduces (CRR =1.00) gives Dyna - Thread superior hydraulics. And, when used installation fatigue and is ideal for better life expectancy than lightwall in combination with Dyna -Flow pipe, retro -fit applications. threadable pipe joints. down sizing often occurs. Corrosion Resistance Ratio (CRR) is a • Unlike lightwall threadable pipe, • Dyna- Thread is fully listed and UL (Underwriters Laboratory) term for Dyna - Thread has no thread gauge approved by UL, ULC, and FM for the estimated life expectancy of a pipe warning. fire sprinkler applications. joint. This is based on the calculated • Dyna- Thread is approved for • The life expectancy of Dyna - Thread wall thickness at the base of the first standard hanger spacing (15 ft. and Sch -40 are equal based on the exposed thread, assumed to be the weakest point of the pipe length. Dyne- O.C.), can be used as earthquake calculated wall thicknesses per UL. sway bracing, and is safe to use as Thread and Sch-40 have the same drops. • The consistent quality of steel used to calculated wall thicknesses at this point make Dyna- Thread facilitates smooth and are both assigned the same CRR of • Dyna- Thread is safer to weld on. threading and lower maintenance 1.00. costs. • Dyna- Thread is more widely The internal surface of all black Allied accepted than lightwall threadable • The exterior of Dyna- Thread is where Sch-40 is specified. protected by a clean, durable mill Tube & Conduit Fire Sprinkler pipe coating for extended shelf life and products up to 4.5000" in diameter is easy paint application. coated with our new Antibacterial Formula, "ABF ". In scientific laboratory test, ABS proved to have superior Specifications & Approvals resistance to microbial colonization of (I) ® ® pipe walls, thereby delaying or possibly Super 40/Dyna- Thread pipe is preventing the onset of manufactured to meet: ASTM A -135, Microbiologically Influenced corrosion Grade A and is in compliance with Listed Approved Listed g y NFPA -13. All sizes of Super a - (MIC) when the First Sprinkler System p er 40 �Yn is first installed. Thread are rated at 300 psi working pressure. Super 40/Dyna- Thread is UL and ULC Listed for wet, dry deluge and Specifications pre- action sprinkler systems and FM NPS Nominal I.D. WI. Wt. (1120 Filled) Pcsl WtiUft (21') WI Lift (24') WIN (25') Approved for use in wet systems. Super In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Litt Lbs; Kg Lbs; Kg Lbs; Kg 40/Dyna Thread can be "hot - dip" r 1.080 1.330 1.75 70 1955 2234 2327 galvanized to meet FM requirement for 25 27.4 2.0 2.60 70 887 1013 1056 dry systems. Super 40/Dyna- Thread is 11/4' 1.408 1.870 2.54 51 2002 2288 2384 approved for all threaded couplings and 32 35.8 2.8 3.78 51 908 1038 1081 welded outlets and is suitable for all 1W 1.639 2.290 3.22 44 2115 2418 2519 roll - grooved, and plain -end fittings. 40 41.6 3.4 4.79 44 959 1097 1145 (See listing information). 2' 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 103? NCO I Flow Control n 16100 S. Lathrop • Harvey, IL 60426 Customer Service: `'/ allied 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882 -5543 TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708 - 339 -1806 S3 - 3 I- 0 2 z . a) 8 • ...... „..., ..... --- ...., Lu . ....... 0 ... ,to•-, . -..p, , . ,... ,, • 7. ; . ... ., . .,. , . .., . ,... ,.„ .. .. . , .. .. _. . .. , ..... . . . ., ... ., ,...., pp . p . ..! ..„ „,. ..., , , .....': Millirl. 11441411411444 • 4 C ■ , ■ I ■ . ■•■ ,.,' , .,, ,,,A. ''14,:::: II . 7 1 .. ... :. : :.,;.:14t1 V III . ■ III 111.1 „ ,....,,...,........„.„.... _ ..„.....:.. ...1 .. _ 0,), ..i.,_ OLNSnl-- IIMI :-.. . ■ -,._ ...-• , k. ell Lill _•,,,,,, I . .„.., ...... , .,.....„. .... ....,„...... Nib II tr)ISL2it Orgg,:.-..L-... 13t14S_..:1. ts, tail .,... „.., . ..... . ... .._, 1 i" ' 01 .5., o a . . Schedule-1O/Schedule-40 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule -10 /Schedule -40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule -10 /Schedule -40 gives you the extra quality assurance you demand. Our Sch -10 (1' / "- 8 ") pipe and Sch-40 (1 "- 2'/ ") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Sch -40 Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wt/Lift (24') Wt/Lift (25') \ Schedule - l0 )r chedule - product can be 4, In; mm In; mm Lbs/Ft; Kg /m Lbs/Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg "hot -dip" galvanized to meet FM requirements for dry systems in 1' 1.049 1.680 2.05 70 2,470 2,822 2,940 accordance with the zinc coating 25 26.6 2.5 3.05 70 1,120 1,280 1,334 specifications of ASTM A -123. 1W 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 Superior Coating 11/2' 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 Our advanced formula mill coating of- 2' 2.067 3.650 5.13 30 2,300 2,628 2,738 fers a clean, durable surface. It is also 50 52.5 5.4 763 30 1,043 1,192 1,242 paint -ready for custom color applications 2W 2.469 5.790 7.86 19 2,310 2,640 2,750 without special preparation. 65 62.7 8.6 11.73 19 1,048 1,197 1,247 The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe $Ch•10 Specifications products up to 4.5000" in diameter is coated with our new Antibacterial For- NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ WVLift (21') Wt/Lift (24') Wt/Lift (25') mula, "ABF". In scientific laboratory In; mm In; mm Lbs/Ft, Kg/m Lbs/Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg test, ABS proved to have superior resis- 1' 1.097 1.400 1.81 91 2,675 3,053 3,185 tance to microbial colonization of pipe 25 279 2.1 2.70 91 1,213 1,385 1,445 walls, thereby delaying or possibly pre- 1W 1.442 1.810 2.52 61 2,319 2,664 2,760 venting the onset of Microbiologically 32 36.6 2.7 3.75 61 1,052 1,208 1,252 Influenced corrosion (MIC) when the 1W 1.682 2.080 3.04 61 2,664 3,045 3,172 First Sprinkler System is first installed. 40 42.7 3.1 4.52 61 1,208 1,381 1,439 American Made 2' 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 Meets "Buy American" requirement 2W 2.635 3.530 5.89 30 2,224 2,542 2,648 and is available through distributors in 65 66.9 5.3 8.77 30 1,009 1,153 1,201 the USA, Canada and Mexico. 3' 3.260 4.330 7.94 19 1,728 1,975 2,057 Specifications & Approvals 80 82.8 6.4 11.82 19 784 896 933 4' 4.260 5.610 11.78 19 2,238 2,558 2,665 Schedule -10 /Schedule -40 pipe are in 90 108.2 8.3 17.53 19 1,015 1,160 1,209 compliance with the following: 5' 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 ASTM A -135, and NFPA 13. Both pipe 6' 6.357 9.290 23.03 10 1,951 2,230 2,322 products have a working pressure rating 150 161.5 13.8 34.27 10 885 1,012 1,053 of 300 psi maximum and also meet the 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 stringent requirement for the following 200 209.5 24.5 59.75 7 1,100 1,256 1,309 tests: • Welded Outlets (1) 4 1:* ( • Hydrostatic Pressure Listed Approved Listed • Side Wall Rupture • Vibration Test *LJCO I Flow Control n 16100 S. Lathrop • Harvey, IL 60426 Customer Service: '/ cjhe� 11350 Norcom Rd. •Philadelphia, PA 19154 (800) 882 -5543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708 - 339 -1806 S5 - 3 1 • Standards and Specifications s (0) ) AON1 S . . INC 1 Dimensions Material Galvanizing Thread Pressure Federal/Other - Rating M.I. Fittings , Class 150 /PN 20 ASME 516.3• ASTM A -197 ASTM A -153 ASME 8120.1+ ASME 816 3• ASME 816.3" Class 300 /PN 50 ASME 816.3• ASTM A•197 ASTM A -153 ASME 8120.1+ ASME 816.3• ‘` M.I. Unions Class 150 /PN 20 ASME 516.39. ASTM A -197 ASTM A -153 ASME 5120.1+ ASME 816.39. ASME 816.39"' Class 250 ASME 816.39• ASTM A•197 ASTM A -153 ASME 8120.1+ ASME 616.39• Class 300 /PN 50 ASME 816.39• ASTM A•197 ASTM A -153 ASME 8120.1+ ASME 816.39• Cast Iron Threaded Fittings Class 125 ASME 816.4• ASTM A -126 (A) ASTM A•153 ASME 81.20.1+ ASME 816.4• ASME 816.411 1 Class 250 ASME 816.4• ASTM A -126 (A) ASTM A -153 ASME 81.20.1+ ASME 816.4• ASME 816.4■ C. 1. Plugs and Bushings ASME 816.14• ASTM A• 126 (A) ASTM A -153 ASME 81.20.1+ ASME 816.14• I WW -P•471 C. 1. Drainage Threaded Fittings ASME B16.12• ASTM A•126 (A) ASTM A -153 ASME 81.20.1+ ASME 816.12• 0 C. 1. Flanges and Flanged Fittings Class 125 (1'-12') ASME 816.1• ASTM A• 126 (A) or (B) ASTM A•153 ASME 81 .20.1+ ASME 816.1 ASME 816.1• Class 125 (14' -up) ASME 816.1• ASTM A -126 (B) ASTM A•153 ASME 81.20.1+ ASME 816.1 ASME 816.1• Class 250 (11 4 -12 4 ) ASME 816.1. ASTM A• 126 (A) or (B) ASTM A -153 ASME 8120.1+ ASME 816.1 ASME 816.1. Class 250 (14' -up) ASME 816.1• ASTM A -126 (B) ASTM A•153 ASME 51.20.1+ ASME 816.1 ASME 816.1• Forged Steel Threaded Fittings Class 2000. 3000. ASTM A105. 6000 ASME 816.11• ASTM A182, ASME81.20.1+ ASME 816.11• ASTM A350 Pipe Nipples Steel Pipe ASTM A733 ASTM A53 ASME 81.20.1+ WWN 351 - Welded Type F or Type E Steel Pipe - Seamless ASTM A733 ASTM A106 Gr. B ASME 81.20.1+ WWN 351 (High Temp.) Brass ASTM 843 ASME 81.20.1+ WWN 351 - 'The standard •an American National standard (ANSI) +ASME 81.20.1 was ANSI 82.1 UFormerly WW -P -501 "Formerly WW -P -521 • •'Formerly WW -U -531 - All PF -149I • , IPS CARBON STEEL PIPE — FIRE PROTECTION PRODUCTS 10.02 VICTAULIC" IS AN ISO 9001 CERTIFIED COMPANY Style 005 FireLock® Rigid Coupling with Vic -Plus® Gasket System V IC Gasket System PRODUCT DESCRIPTION FireLock Style 005 rigid coupling has a unique. patented angle -pad design which allows the housings to offset while clamping the grooves By permitting the housings to slide on the angled bolt pads, rigidity sr""'" is obtained 1 1 % The FireLock couplings provide rigidity for valve connections, fire mains and long straight runs Support .�lir and hanging requirements correspond to NFPA 13 Sprinkler Systems Angle -pad design permits X4.2 ' assembly by removing one nuUbolt and swinging the housing-over the gasket This reduces components to handle during assembly, speeds and eases installation on pipe grooved to -1 • ; Victaulic specifications '�" Style 005 FireLock couplings with the Vic - Plus"" Gasket System are designed and recommended for use ONLY on fire protection systems. Patented Vic -Plus Gasket System: Vlctauhc' now offers a gasket system which requires no field lubrication on wet pipe systems. The Vic- Plus"' System (patented) is dry, clean, and non -toxic It reduces assembly time substantially and IIeliminates the mess and chance of over - lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1 -100) for supplemental lubrication requirements ICI 1i'I ® 0 ® ILK] VdS 5 LPC and KIS ApproveP 9 d, Exagge ar ,;;,,;1 Request Viclaulic see notes on 3 e publication 10 01 ton details. DIMENSIONS Y 1 .—Z— i Pipe Size Dimensions ter xi►• Iriixlk Inches7mm Nominal Outside Work Max. d Pipe End ® Bolt/Nut ' 1� Diameter Diameter Press. §' Load' J �,�,g Inches/rim Inches/mm PSUkPe t No.- Size W Ea. LbsJN InJmm Inches/rim X Y Z Lbs./kg 1 '14 1 660 350 755 0 05 Rated for wet and dry sprinkler systems at 350 psi (2413 kPa) 32 42 a 2413 3370 1,2 2 11s X 2'/ 2 i5 d SO 1 88 1 2 7° 114 148 0.5 1 /_ 1 900 40 a9 3 Z 50 990 0 05 , ;/P X 2 r+ 3.00 a 75 1 88 1 2 76 121 148 0.5 for 1 - 4" (32 - 100 mm) sizes and 300 psi (2068 kPa) for 2 2 375 350 1550 0 07 3 50 5 25 1 88 1 6 4v,- 8° (108 - 200 mm) sizes, 50 60,3 2413 6900 1 2 '/y X 2'1 89 133 146 o 7 Schedule 10 roll grooved or 2'72 2 875 350 2270 0.07 4 00 5 75 1 88 1 9 Schedule 40 cut or roll 65 73.0 2413 10110 , 7 2 /4 X zl!2 102 lab 148 0 9 grooved steel pipe. Style 005 76,1 mm 3.000 2a ° 11 010 007 4 13 5 75 1 88 1 9 IS rigid and does not 2 113 x 2'h 1 03 146 148 0,9 3 3 3365 U 07 2 1 /a X 214 4 63 6 13 1 88 2 1 accommodate expansion, 90 86.9 6.9 2413 14995 1 7 contraction or angular 4 118 156 148 1 0 g 4 500 350 5565 0 16 5 75 7 25 2 13 3 1 deflection 100 114 3 2413 24770 4 I 2 - /, X 2 /2 146 184 54 4 250 300 4255 U 16 1 4 103,0 mm 1 oa D lr 5 63 7 25 2 13 3 1 2068 18940 4.1 'y X 2 •- 143 184 5a 1 4 5 5 563 300 7290 0 16 2 - / 23'4 , 6 83 900 2 13 4 5 125 141,3 2068 32445 4 1 X 715 229 54 2,0 133.0 mil 5 250 300 6495 0 16 6 63 9 00 2 13 4 5 133 0 2068 28900 4 1 / x 21 /4 168 229 54 2 0 139.7 mm 5 500 300 7125 0 16 2 - ,: X 21/, 6 88 900 2 13 4 8 139,7 2068 31715 4 6 6 625 300 1 229 54 4 2 150 1643 10340 U 76 800 1000 213 5 2068 46020 41 2 - ' X 2 203 2 54 2 3 159,0 mm 6 250 300 9200 0 16 7 63 1000 2.13 5 5 2 - 5 X 4 ' ! e 194 159.0 2068 40955 4 1 !^ 254 54 2 5 165.1 mm 6 500 300 9955 0 16 8 15 10 00 2 13 5 5 165 1 2068 44295 4.1 2 - 1 12 X 2'' 207 254 54 2 5 8 A 66 300 17525 0 19 10 50 13 13 2 63 11 3 400 219,1 2068 78000 4 8 2 - 5 ', X 417. ,61 334 67 ' e• 4 1 Refer to notes on page 2 5 7 REGISTERED TRADEMARK OF 'ACTAULIC - 0 2OPYRIGHT 2004 VICTAUUC - PRINTED IN U.S A. - SKu IWCAS.6TMHPN 1538 REV H Victaulic Company of America • Phone 1 - PICK - VIC (1 • Fax 610 250 - 8817 • e -mail pickvic@viclaulic.com Victaulic Company of Canada • Phone 905 -884 -7444 • Fax 905- 884 -9774 • e -mail viccanada @victaulic corn Victaulic Europe • Phone•32.9- 381 -1500 • Fax. 32-9-380-4438 • e viceoro@victaultc.be Victaulic America Latina • Phone. 610 -559 -3300 • Fax 610 -559 -3608 • e -mail viral @victautic can Victaulic Asia Pacific • Phone: 86 -21- 58855151 • Fax 86 -21- 58851298 • e -mail vicap@victaulic corn �' C' 4 1 0.02 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A -536, grade 65 -45 -12 Ductile iron conforming to AS TM A -395, grade 65-45-15, is available upon special request Housing Coating: Orange enamel • Optional: Hot dipped galvanized Gasket: • Grade "E" EPDM - Type A Vic -Plus Gasket System A (Violet color code) Firelock products have been Listed by Underwriters Laboratories Inc and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure us- ing the Grade "E" Type A Vic -Plus Gasket System, requiring no field lubrication for most installation condi- tions For dry services. Victaulic continues to recommend the use of Grade "E" I ype A FlushSeal Gasket Contact Victaulic for details Bolts /Nuts: Heat - treated plated carbon steel. trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183. :1 Standard gasket and F1ushSoal gasket approved for dry pipe systems to -40'F ( -40 - C) Based on 'typical" pipe surface conditions, supplemental lubricant is recommended for services installed below OF (-18 'Cr arid fro as dry pipe systems of systems to be subjected to air tests prior to being filled with water, Supplemental rubrication may also be rquirod on pipe with i aised or undercut field seams or pipe that has voids and /or cracks at the weld seams Victaulic continues to recommend the use of FlushSeal gaskets for dry services LISTINGS /APPROVALS The information provided below is based on the latest listing and approval data at the time of publication Listings /Approvals are subject to change and /or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals Rated Working Pressure - PSI Rated Working Pressure - PSI Rated Working Pressure - PSI Pipe Size Pipe Size Pipe Size Sch. Inches UL ULC FM Sch. Inches UL ULC FM Sch. inches UL ULC FM 5 1 3 175 175 175 EL 1 /, - 2 300 N/A N/A MT 11, 2 300 N/A N/A 1 /, - 4 350 350 350 ET 171 - 2 300 N/A N/A STF 1 /, - 4 N/A NiA 300 10, 40 5 - 8 300 300 300 EZ 4 6 3005 N/A 300 Stead Thd y 1 /, - 2 NiA N/A 300 ELT 1 - 2 300 300 N/A FF 1 - 4 N/A N/A 300 TF 3 - 8 N/A N/A 300 DF 1 - 4 300 300 300 GAL -7 1 2 300 N/A N/A WLS 1 - 2 300 300 N/A DT 1 2 300 300 N/A MLT 1'/, - 2 300 N/A N/A XL 1 - 3 300 300 300 EF 1 4 175@ N/A 175 MF 1 4 - 4 300 N/A 300' ' FM approved for service in Tl /z - 4 pipe # UL Listed for service up to 4' pipe only WUL Lusted For service up to 3' only PIPE SCHEDULE NOTES: 5 refers to Listed /Approved Schedule 5 steel sprinkler pipe 10 refers to Listed /Approved Schedule 10 steel sprinkler pipe 40 refers to Listed /Approved Schedule 40 steel sprinkler pipe ELT refers to Listed steel sprinkler pipe manufactured by Allied Tube & Conduit DF refers to Listed/Approved Dyne Flow steel sprinkler pipe manufactured by Allied Tube & Conduit DT refers to Listed Dyna Thread steel spunkier pipe manufactured by Allied Tube & Conduit EF refers to Lister) /Approved Eddy Flow steel sprinkler pipe manufactured by Bull Moose I ube Co EL refers to Listed Eddykte steel sprinkler pipe manufactured by Bull Moose Tube Co El refers to Listed Eddythread 40 steel sprinkler pipe manufactured by Bull Moose Tube Co EZ refers to Listed EZ -Flow steel spnnkler pipe manufactured by Northwest Pipe & Casing Co FE refers to Listed Fire Flo steel sprinkler pipe manufactured by Youngstown Tube Co GAL 7 refers to Listed steel sprinkler pipe manufactured by IDOD Systems. LLC MLT refs to Listed steel sprinkler pipe manufactured by Wheatland Tube Company MF refers to Listed Mega-Flow steel sprinkler pipe manfactured by Wheatland Tube Company MT refers to Listed Mena Thread ,tees spnnkler pipe manufactured by Wheatland Tube Company STr refers to Listed Steady Flow steel sprinkler pipe manufactured by AMS Tube Corporation Steady Thread refers to Appproved steel sprinkler pipe manufactured by AMS Tube Corporation TF refers to Tex Flow steel sprinkler pipe manufactured by Tex -Tube Company WLS refers to Listed /Approved steel spnnkler pipe manufactured by Wheatland Tube Company :AL refers to Listed XL or XL II steel sprinkler pipe manufactured by Allied Tube & Conduit Corp, NOTES ' Working Pressure and End Load are total, from all internal and eternal loads based on standard weight (ANSI) steel pipe. standard roll or cut grooved Sr accorcance with Victaulic specircatons Contact Victaulic for performance on other pipe WARNING FOR ONE TIME FIELD TEST ONLY. the Maximum Joint Working Pressure may be increase° to 1 1 , times the figures shown t For field installation wily Firelock Style 003 couplings are essentially rigid and do not accommodate expansion/contraction Numbei of bolts required equals number of housing segments Metric thread size bolts are available (color coded gold) for all coupling sizes upon request Con :act Victaulic for details § Style 005 couplings are VdS and LPC Approved to 12 Bar 075 psi) WARNING Depressurize and cr3111 the piping system before attarnpung to install ienlcve. or adjust any V.;tdub,: piping product-, This product shall be manufactured by Victaulic Company All products shall he installed in accordance with current Victaulic uuta!latioru'assernbiy i lstr rs Victaulic reserves the tight to change_ product specification, Designs and stnndar -j equipment without notice and without incurring ibligations 2 Style 005 FlreLock? Rigid Coupling IPS CARBON STEEL PIPE - GROOVED COUPLINGS 06.05 1 %, VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY Style 7 5 Coupling PRODUCT DESCRIPTION Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50 lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi (3450 kPa) depending on size Housings are cast in two identical pieces in all sizes. Hot -dip galvanized . 4. and special coatings are available for all sizes. t• T / ® FM Seavcteuilc N - ‘4,..V...-:.A.. N. XN�-- +aR0`. publication 10 01 for details Li lir I Exaggerated for clarity DIMENSIONS 1.--y--.1 �r I Z Pipe She Malt. Max. Allow. F►. Dimensions �� Deflect. Work End Pipe t Bolt/Nut Incheshni0lmeters W r I 1 1 I rig I Nominal Actual Pres. Load End t Per Pipe No.- Size Each li � ) &I I\ Diameter Out. PSI' Lbs • Sep. In./FL 1 i1 I Inhnm In./rem kPa 680 N 0 h 0 0 6 0 5 Deg. Deg, mm/m 7 mm X Y Z b s. kg 1 1 315 500 2.38 4 27 1.77 1 3 1 10 25 33.4 3450 3025 0.1.6 2° - 43' 48 2 - 3 /e X 2 61 108 45 0.6 1 1.660 500 1080 0 - 006 0 45 1 2.68 4 61 1.77 1 4 32 42.2 3450 4805 0 - 1,6 2° - 10 38 2 /8 X 2 68 117 45 0.6 1'/2 1 900 500 1,420 0 - 0.06 0 40 2 91 4.82 1 77 1.5 40 48.3 3450 6320 0 - 1.6 1 ° - 56' 33 2 - / X 2 74 122 45 0.6 2 2 375 500 2.215 0 - 0 06 1 31' 0.32 2 3 /e X 2 3 43 5.22 1 88 1.7 50 60.3 3450 9860 0.1.6 26 87 133 48 0.8 2 2 875 500 3,245 0 - 0 06 1° - 15' 0 26 2 .3 / X 2 3.88 568 1 88 1 9 65 73.0 3450 14440 0 - 1.6 22 98 144 48 0.9 3 000 500 3.535 0 - 0 06 0 26 76,1 mm 1 ° -12' 2 -3/2X2 400 5.90 1.88 19 76,1 3450 15730 0.1.6 22 i 102 150 48 0.9 3 80 88.9 500 21 0 6 6 1° - 2 0 2 - 1 / 2 X 2 �'� 0 1 2 ,3 3 4 000 500 6.300 0 - 0.06 0 19 500 7 50 1 88 2 9 90 101.6 3450 28035 0 - 1.6 0° - 54' 16 2 - 1 /2 X 234 127 191 48 1,3 4 4 500 500 7.950 0 - 0 13 0.34 2 1 5.80 8 03 2 13 4.1 100 114.3 3450 35380 0 - 3.2 1 ° 36' 28 2 / X 2 /• 147 204 54 1.9 108.0 mm 4250 450 6,380 0 - 013 1 ° - 41' 035 2 12X70.0 5.55 779 2.13 37 108,0 3100 28395 0 - 3.2 29 141 198 54 1,7 4 5 000 450 8.820 0- 0 13 0 25 s e 6 13 9.43 2 13 5 5 1 120 127.0 3100 39250 0 - 3.2 ° 26' 21 2 - / X 3 /' 156 240 54 2.5 5 5563 450 10.935 0.013 1 ° - 18, 027 2 s /e X3' / 6.88 1007 213 58 125 141,3 3100 48660 0 - 3.2 23 175 256 54 2.6 133.0 mm 5250 450 9,735 0 - 013 1 ° - 21' 028 2 16X825 655 937 213 60 133.0 3100 43325 0 - 3.2 24 166 238 54 2.7 739.7 mm 5 500 450 10,665 0.013 1 ° - 18' 0.28 2 - s /8 X 31/4 6.80 9 59 2.13 6.3 139,7 3100 47460 0 - 3.2 24 173 244 54 2,9 • 152,4 mm 6524 3100 12,735 p 0 3.2 1 ° - 12' O t8 1 2 - s /8 X 3 18 8 1 2 68 8 1 48 8 6 2.8 2 6 6 625 450 15,525 0 .0 13 0 23 800 11 07 2 13 7 0 150 168.3 3100 69085 0 - 3 2 1 ° 5 18 2 - s /3 X 3'/ 203 281 54 3.2 Table continued on page 2. °t 0 Refer to notes on page 2 a REGISTERED TRADEMARK OF VICTAUUC - 0 COPYRIGHT 2033 VICTAUUC - PRINTED IN U E.A. 1470 REV F Victaulic Company of America • Phone 1- 900 - PICK -VIC (1- 800 -742 58421 • Fax 610- 250 -8817 • e -read plclonc:7 v.ctaulic con Victaulic Company of Canada • Phone 905- 884 -7444 • fax 905 - 884 -9774 • e-mail viccanatta 'viclaulic corn v'ctat.iic Europe • Phone 32-9-381-1500 • Fax 32 -9- 330.4438 • e -mail viceuro01victauhc be V'ctailic America Latina • Phone 610- 559 -3300 • Fax; 610 - 559 -3606 • e -mad vncal'a vlctaul c corn jctaulics V.ctat,lir Asia Pacanc • Phone 65- 6235 -3035 • Fax 55- 6235 -0535 • e -mad vicap@vi aulic coin 06 .05 DIMENSIONS Y �I [4-Z I Lbs.' Sep. P She . Max. Allow. Deflect. Fr. Dimensions AP ra• I/11 Work End Pipe C t Solt/Nut I nehea/mllllmeters w. t r Diameter Ou oil MI Nominal Actual Pres. Load End} Per Cplg. In Pipe L No.- Size Each 1 Iii Out. Die. P51' JF Inches Lbs. LALIPA I �l'f�' InJmm InJmm kPe N IDeg. mmlm mm X Z kg �� / Mil 159,0 mm 6.250 450 13,800 0 3 1' 9 0 24 2 - 16 X 82 5 7 63 10 49 2.13 6 8 159.0 3100 61405 0 - 3, 2 20 194 266 54 3.1 165,1 mm 6.500 450 14,940 0 - 0.13 0 23 ® 7.84 10 66 2.06 7.2 1 165.1 3100 66483 0 - 3,2 - 6' 19 199 271 52 3.3 1. 203.2 mm# 8 000 450 22,635 0 - 0 13 0° - 54 0 16 2 3 /4 X 4 9.72 13.33 2 31 12 6 203.2 3100 100725 0 - 3,2 13 247 339 58 5.7 8 8 625 450 26,280 0 - 0 13 0° - 50 0 18 2 - 3 /, X 4'/4 10 34 13.97 2.32 12 4 200 219.1 3100 116945 0 - 3,2 14 263 355 59 5.6 254.0 mm# 10 000 350 27,500 0 - 0.13 0° - 43' 0.15 2 - 'le X 5' /i 12 16 15 81 2 53 20.8 254,0 2400 122375 0 - 3.2 11 309 402 64 9.4 304.8 mm# 12 000 350 39,500 0 - 013 0 - 36' 013 2 - ' /B X 5' /z 14.16 17 69 2 53 23 6 304.8 2400 175775 0 - 3,2 9 360 449 64 10,7 # Style 74 Couplings I@ Refer to notes below. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Housing Coating: Orange enamel • Optional: Hot dipped galvanized and others. Gasket: (specify choice')t • Grade "E" EPDM EPDM (Green color code). Temperature range -30 °F to 230 °F ( -34 °C to 110 °C). Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services UL classified in accordance with ANSI /NSF 61 for cold 86 °F ( 30 °C) and hot 180 °F ( 82 °C) potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade "T' nitrite Nitrile (Orange color code). Temperature range -20 °F to 180 °F ( -29 °C to 82 °C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; except hot, dry air over 140 °F ( 60 °C) and water over 150 °F ( 66 °C). NOT RECOMMEND- ED FOR HOT WATER SERVICES. 'Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended tSupplemental lubricant is recommended for services installed at or continuously operating below 0 °F (- 18 °C). Bolts /Nuts: Heat treated carbon steel, zinc plated to ASTM B -633, track -head conforming to physical properties of ASTM A -183 minimum tensile 110,000 psi (758340 kPa) NOTES ' working Pressure and End Load are total. from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications Contact Victaulic for performance on other pipe WARNING FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1' /2 times the figures shown • Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe Figures for standard Cut grooved pipe may be doubled These figures are maximums, for design and installation purposes these figures should be reduced by 50 for 3 / 4 - 3 /z (20 - 90 mm), 25 for 4' (100 mm) and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request Contact Victaulic for details WARNING Depressurize and drain the piping system before attempting to install. remove, or adjust any Victaulic piping products. This product shall be manufactured by Victaulic Company All products shall be installed in accordance with current Victaulic installation/assembly instructions Victaulic reserves the right to change product specifications. designs and standard equipment without notice and without incurring obligations 2 Style 75 Coupling 07.01 No. 50 and No. 51 E Concentric/Eccentric Reducers 1 �� r - E to E-+t Steel (except as rioted) Th[ No. 50 No. 51 No. 50 No. 51 Approx. Approx. Approx. Approx. Nominal E to E Wgt. Ea. E to E Wgt Ea. Nominal E to E Wgt. Es. E to E Wgt. Ea. Size Inches Lbs. Inches Lbs. Size Inches Lbs. Inches Lbs. Inches/mm mm kg mm kg Inches/mm mm kg mm kg 1'/, X 3 /. 19 - - 4 X 2 300'd 24 4 00 d 33 32 2 20 0,9 - - 100 X 50 76 1,1 102 1,5 X 1 19 - - X 2'1 300'd 27 4 00 d 3 '.,X 25 0.9 - - X 65 76 1,2 102 1.5 172 X q. 14 - - X 3 300'd 32 400 35 10 X 20 06 - - X 80 76 14 102 1,6 X 1 250'd 08 850 45 X 3'/2 3 00 0 29 1000 80 2 25 64 0 1 216 % 0 X 90 7 6 1 3 254 3 6 X 1/ 250 10 - - 5 X 2 400 90 1100 52 3 32 64 0.5 - - 125 X 50 102 4 1 279 2 4 2 X - V , 2 50' d 0.9 900 2 0 X 2'/; 1 1 00 11 0 11 00 10 8 50 X 20 64 0,3 229 09 X 65 279 5,0 279 4,4 X 1 250'd 07 900 2.3 X 3 4.000 55 1100 111 6 25 64 0.3 229 1,0 X 80 102 2 5 279 5,0 X 1 250'd 12 900 46 X 4 3 50 0 43 5 00 0 120 X 32 61 0,5 229 2.1 X 100 89 1.9 127 5.4 X 1 250'd 10 900 46 6 X 1 400'0 50 1150 145 6 40 64 0.5 229 2,1 150 6 25 102 2.3 292 6.6 2 X 1 i4 1 3 33 3 X Viz 5 5 66 X 20 0.6 1,5 X 40 2 5 X 1 950 36 950 35 X 2 400'd 66 1150 145 X 25 241 15 241 1,6 X 50 102 3,0 292 6.6 X 1 250'd 33 950 X 2'/7 400'd 64 1150 142 X 32 64 1 5 241 X 65 102 2,9 292 6 4 X 1./; 250'0 36 950 37 X 3 400'd 64 550c1 150 X 40 64 1 6 241 1.7 X 80 102 2 9 140 6 8 X 2 2500 39 950 43 X 4 4000 65 5 50 d 170 X 50 64 1.8 241 2,0 X 100 102 2 9 140 7,7 3 X 1 /4 15 45 X 5 4 00 d 64 5 50 d 170 80 X 20 0 7 2.0 X 125 102 2.9 140 7 7 X 1 250'd 13 950 48 8 X 2 1600' 7.9 1200 261 X 25 64 0.6 241 2,2 200 X 65 406 3.6 305 11,8 X 1 30 48 X 3 5.00d 93 1200 220 X 32 1,4 2,2 x 80 127 4 2 305 10,0 X 1 2 50 d 51 950 51 X 4 5 00 d 104 1200 230 X 40 64 2,3 241 2,3 X 100 127 4 8 305 10,4 X 2 250'd 1.6 3 50 d 60 X 5 5 00 d 116 1200 23.0 X 50 64 0 7 89 2 7 X 125 127 5 2 305 10 4 X 2'1_ 250'0 18 3 50 0 70 X 6 5000 119 6000 240 X 65 64 02 89 3 X 150 127 5 152 109 X 76,1 n1m 2500 21 - - 10 X 4 6000 197 1300 320 64 1,0 - - 250 X 100 152 8 9 330 11,5 3 X 3 2 50 d 20 950 70 X. 5 343 346 90 X 80 64 09 241 3,2 X 125 15,6 15,7 4 X 1 300'd 30 1000 65 X 6 6 00 d 20.0 1300 369 1(X1 X 25 76 1,1 254 2 9 X 150 152 9,1 330 167 X 174 46 - - X 8 6.00d 220 700 216 X 32 e 1 - - X 200 152 10 0 178 9.8 X 1'1: 10 00 6 9 1000 8 1 fame continued on page 9. X 40 254 3,1 254 3,7 See notes on page 9 8 Grooved End Fittings i o7.01 I i — No. 50 and No. 51 Concentric/Eccentric Reducers rto El Steel (except as noted) -,-...,- r— E to E IM No. 50 No. 51 No. 50 No, 51 Nominal Approx. Approx. Approx. E to E Wgt. Ea. E to E Wgt. Ea. Nominal Approx. Size Inches Lbs. inches Lbs. Size E h E WLb Lbs. n th E W . Ea. Inches/mm mm kg mm kg Inches Ls Inches bs t 2 X 4 9 Inches/mm mm kg mm kg 440 1400 480 18 X 14 7 00 300 x 100 20,0 356 21,5 450 x 350 1 3 00 41,3 3 15 381 41 3 0 X 6 d 24 6 la OU 381 41,3 381 41,3 X •ISO 178 1 1.2 356 22 7 X 16 15 1 91 3 13 381 91 3 0 X 8 7 p0 d 52 0 14 00 3'1 a 1 3 381 a 1 3 x =00 00 5 2,6 35 0 53 5 20 X 10 20 00 110 0 20 00 177 0 21,3 500 X 250 308 49,9 X 10 7.00 d 39 0 14 00 57 p Sos 80,3 X 250 178 177 12 2000 1"200 2000 1200 356 X 25 9 X 300 508 54 A 14 X 6 13 00 65 0 1300 006 54 4 60 350 X 150 330 29,5 330 27 2 X 3 :< 350 5 Z 08 67,9 80 149 0 20 00 149 0 2 5 X 8 1300 650 1300 600 0 0 60 9 X b 2000 120 0 20 0 x 200 330 29 5 330 0 1 0 27 2 X 400 400 508 54 4 508 54 4 X 10 1300 660 1300 65.0 X 18 X 250 330 29,9 330 29 5 20.00 136 0 2 5 0U 136 61,7 U X 12 X 450 508 61,7 508 6t,7 13.00 fi80 1300 X 12 330 38 8 330 66 0 24 X 10 20 00 142 0 29 9 600 X 250 Z 5 00 142 0 16 X 8 14 00 73 0 14 00 73 0 508 6 0 006 64 0 X 3 2 2080 150 0 20 5 00 150 0 400 X 200 356 33,1 355 331 x 300 508 68,0 002 68,0 X 10 14 00 73 0 1400 73 0 X X 3 5 20 00 162 0 2080 162 0 250 356 33 1 355 33 I X 350 508 73 5 X 12 1400 730 1400 730 x 16 508 6 5 Z0 80 162 0 2500 1 X 300 356 33,1 355 33 1 0 X 400 508 73.5 508 73. 3, 5 X 14 1a00 730 1a00 730 X 18 X 350 356 33 1 355 33 1 2080 162 0 20 5 00 1 73 0 18 X 10 X 450 508 73 5 508 73 5 1500 91 0 1500 91 0 X 20 20 00 151 0 2080 190 0 450 X 250 381 41,3 381 41 3 x 500 508 68,5 508 86,2 X 12 1500 910 1500 910 X 300 381 413 381 41,3 (dl Ductile iron Contact VictauUC for details. 'Available with male threaded small end No 52 0 Steel eccentric reducers available through 30 - (750 rem), contact Victaulic for dimensions Grooved End Fittings 9 ®TDLCO www.tolco.com brand orNIBCCI Revision 5/24/2001 Fig. 2 - Adjustable Band Hanger ® Fig. 2NFPA - Adjustable Band Hanger with Reduced Rod Size Range — Size 2 thru 4" pipe. Material — Carbon Steel, Pre- Galvanized q; ■ Function — Recommended for the suspension of non - insulated , ,. H c .-• pipe or insulated pipe with Fig. 220 shield. ,. Fig. 2NFPA accommodates the reduced rod schedule of the ;/ National Fire Protection Association Pamphlet 13. r` Approvals — Underwriters' Laboratories Listed in the USA (UL) I . and Canada (cUL). Factory Mutual Engineering approved. 1 Conforms to Federal Specification B WW -H -171 E, Type 10 and Manufacturers Standardization Society � 4, ' SP -69, Type 10. , Finish — Pre - Galvanized A Note — Available in Stainless Steel materials. Order By — Figure number, pipe size and material —_ • Dimensions • Weights Pipe Max. Rec. Approx WtJl 00 Size Rod Size A B C Load Lbs. Fig. 2 Fig. 2NFPA 2' 4 1/2' 5' 4 4'4 1 600 41 40 3 1/2* 6 4' / 1' /, 600 45 43 3'4 1/2* 73/8 51/4 21/8 600 52 50 4 5/8' 7' /e 5 1' 4 1000 59 56 5 5 /8•• 9 6' 4 2'/, 1250 97 95 6 3/4** 9 672 1' 4 1250 139 105 • 3/8" nut is used when NFPA rod sizing is requested. •• 1 /2" nut is used when NFPA rod sizing is requested. • ® Main OffiicelManufacnumg Facility • 1375 Sampson Ave • Corona, CA 92879 • Ph 909 737 5599 • Fax 909 737 0330 Customer Service • 800 786 5266 w ww tolcacom • ®TOLCD vwwv.tolco.com a brand of NI BCD Revision 8/30/2002 Fig. 4 - Standard Pipe Clamp Q► Fig. 4F - Standard Pipe Clamp Felt Lined Sc® Fig. 4PVC - Standard Pipe Clamp PVC Coated B �- Size Range — (Fig. 4) Size 1/2" thru 30" pipe. - . Size Range — (Fig. 4F) Size 1/2" thru 2'/:" copper tubing Material — Carbon Steel �,. . . f Function — Recommended for the suspension of non - insulated pipe or insulated pipe r r '' � / ° i with Fig. 220 shields. (Use Fig. 330 Weldless Eye Nut, Fig. 102 Eye Rod or Fig. 101 i I r 9 I , Welded Eye Rod.) Also recommended for attachment of sway bracing up to 3 pipe o j / size, for larger pipe sizes use Fig. 4A. Fig. 4F and Fig. 4PVC are designed to reduce -,. ,`' f f noise and vibration and/or prevent electrolysis.f L Approvals — Underwriters' Laboratories Listed in the USA (UL), Canada (cUL) 2. 3/4" - 8 ", and approved by Factory Mutual Engineering, 3/4" - 8 ". Federal Specification I ,. .� � C 'i6 / WW- H -171E, Type 4, 11/2" thru 24" and Manufacturers Standardization Society SP -69, ! " Type 4. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning - -- 's,-‘' Fig. 4 and Development (OSHPD). " `I' Note — When the Fig. 4 is used as a sway brace, to ensure j `/ r performance, the UL Listing requires that it must be used I '* ; / ' f � ' with other TOLCO' brace products. ti Maximum Temperature — 750 °F ( %f ; Finish — Plain `., Note — Available in Electro- Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, pipe size and finish. Fig. 4F Order Note — When ordering Fig. 4F allow for 3/16" felt on each half of clamp. Fig. 4PVC Dimensions • Weights Pipe Max. Design Load Lbs. Size A B D For Service Temp. Approx. Bolt Size 650° 750 °F Wt. /100 1/2 3 1/4 11, 11, 5/16 500 445 29 3/4 3'/,6 1/4 1 114 5/16 500 445 31 1 3 °/,6 1/4 1'/. 1V,, 5/16 500 445 35 11. 4' /,, 1/2 11, 1"/,, 5/16 500 445 40 1'1 4 ° /, 5/16 1 1'/, 5/16 800 715 42 2 ' 5 °/, 1/2 2 2'/. 39 1040 930 93 2'6' 6' /,, 9/16 2'/2 2 1/2 1040 930 126 3* 7 5/8 2'/, 31„ 1/2 1040 930 141 3 7 " /,e 3/8 3'/, 3 1/2 1040 930 154 4 8'/ 5/8 3'/,, 3 "/,, 5/8 1040 930 229 5 9' /. 3/4 3' /, 4'/, 5/8 1040 930 261 , 6 11 3/4 4 5'/, 3/4 1615 1440 537 8 13 ° /i, 1 5 6 3/4 1615 1440 625 10 1612 1 7'/, 7' /. 7/8 2490 2220 1378 12 1812 1 8'/, 8'/. 7/8 2490 2220 1574 14 20 1' /, 9 9 7/8 2490 2220 2103 16 23 17, 101, 101. 7/8 2490 2220 2314 18 257, 11. 11' 6 11'/ 1 3060 2730 3276 20 28 1' /, 121 12'/2 1'/, 3060 2730 3863 24 3312 VI, 151, 151. 1' /, 3060 2730 5222 30 41 2 19 19 1 3500 3360 10511 76 Main Office/Manufacturing Facility • 1375 Sampson Ave • Corona. CA 92579 • Ph 909 737 5 599 • Fax 309 7;7 0330 Customer Service • 800 786 5266 www.tolcacom ®TDLCD www.tolco.com 9 brand of INIIBC0 Revision 8/13/2001 Fig. 69 - Beam Clamp Retaining Strap ® Size Range — 3/8" thru 7/8" rod by 4" thru 16" length.* Function — To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (1999) 6- 4.7.1. • Important Note — Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mecha- nism of some kind such as a hex nut or the beveled locking slot on the TOLCOTh Fig. 69R will provide a more secure B reliable installation. Approvals — Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). Finish — Pre - Galvanized Order By — Figure number, type, length "B" and rod size being used with beam clamp Note — Minimum return on Strap: 1". Dimensions • Weights lin Type Rod Size A Hole Size B u '�7 // /// 1 3/8 7/16 Specify 1 /2 9/16 Specify ` 1 . 1 2 5/8 11/16 Specify = =' 3/4 13/16 Specify z �� 3 3/8 - 7/8 Specify Specify it Longer lengths are available, consult factory. P ,, / / / //` ► 1 ill R. Ofrice/Manufaetunng Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph 909 737 5599 • Fax 909 737 0330 Customer Service • 800 786 5266 61 www.tolco.cam • _ ®TOLCO www.toico.com brand oI NIBCO. Revision 3/28/2003 Size 910 - Swivel Sway Brace Fitting ® ze Range — 1" and 1 bracing pipe. For brace pipe sizes larger than 1'/n ", use TOLCO Fig. 980. component of State of California OSHPD Approved Material — Carbon Steel Seismic Restraints System Function — For bracing pipe against sway and seismic disturbances. The building attachment component of a sway brace system; the Fig. 910 is used in conjunction with the Fig. 1001, Fig. 1000 or with a Fig. 4A Pipe Clamp and joined together with a brace pipe per NFPA 13. D A Features — This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. , -. - t % , NFPA 13 (1999 Edition) Table 6 -4.5.9 indicates clearly that fastener table load values are based only on concentric loading. Universal swivel design allows; 0 Fig. 910 to be attached at any surface angle. All steel construction. NFPA , 13 (1999 Edition) Table 6- 4.5.8: 1" Schedule 40 bracing pipe maximum 7'0 ". P 1'/4' Schedule 40 bracing pipe maximum 9'0 ". Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). Note — The Fig. 910 Swivel Attachment and the Fig. 1001, Fig. 1000 , or Fig. 4A Pipe Clamp make up a sway brace system of (UL) Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA). Finish — Plain Note — Available in Electro- Galvanized and HDG finish or Stainless Steel materials. er Order By — Figure number, pipe size and finish. Note — Specific weight load conditions may require more , than one fastener to the building surface. Sway brace attachments may be ordered with multiple and/or larg- er fastener mounting holes. Consult the factory. The • Fig. 910 is precision manufactured to perform its func- ` tion as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 910 must be used only with other TOLCO bracing products. Dimensions • Weights A B D Hole Max. Design Approx. Pipe Size Size E F Load Lbs. Wt. /100 1 2 1 '/7 3 9/16 2 2 2015 88 1'/. 1 1 /,e 3 9/16 2 /,e 2 2015 99 158 Main Office/Manufacturing Facility • 1375 Sampson Ave • Corona, CA 92879 • Ph 909 737,5599 • fax 909 737 0330 Customer Service • 8000 786 5256 www.tolcacom RED HEAD' ANCHOR /NO SYSTEMS Submittal Information Trubolt Wedge INSTALLATION STEPS wr 1. Using a bit whose diameter equals the anchor BSI . SPECIFIED FOR ANCHORAGE INTO CONCRETE I diameter, drill hole to any depth exceeding the Wedge anchors feature a type 18 -8 stainless steel split .0.; = e. minimum embedment dean hole. ,... expansion ring and a threaded stud bolt body and integral b-_: ■ •-:.. cone expander, nut and washer. Anchor bodies are made of = °' \ ''.• I plated carbon steel, hot - dipped galvanized carbon steel, type pi 1 304 stainless steel or type 316 stainless steel as identified in 2. Assemble anchor with nut and washer so that _ = the drawings or other notations. the top of the nut Is flush with die top of the I I : o. n -- . anchor. Drive anchor through material to be The exposed end of the anchor is stamped to identify anchor .a -, a length. Stampings should be preserved during installation for • ' °''o • fastene so that nut and washer are flush with any subsequent embedment verification. 43:0 0 . ("=: • surface of material Use carbide tipped hammer drill bits made in accordance to ANSI B212.15- \ 3. Expand anchor by tightening nut 3 to S turns, 1994 to install anchors. k I or to the specific torque requirement Anchors are tested to ASTM E488 criteria and listed by ICC (formerly 130) and 0 % ' 0, (see selection chard. • ..,0:5, SBCCI. Anchors are listed by the following agendes as required by the local :•6 ' •t, o building code: Ul, FM, City of Los Angeles, California State Fire Marshal and ..� -., Cal Trans. APPROVALS /LISTINGS LENGTH INDICATION CODE * Meets or exceeds U.S. Government G.S.A. cone I (1146TH OF ANCHOR CODE I LE21611I OF £80108 Specification FF -S-32S Group II, Type 4, Class 1 A ) 1.112 < 2 (38) < 508! x 6-I/1 <7 (US X< < 17791 a 1 2 < 2 -I/2 (50.8 < 635) 1 1 7 < 7 -U2 (1779 < 1903) Underwriters Laboratories c 12.1/2 < 3 (633 < 76.2) M I 7 -1/2 <8 (1903 < 20313 0 i3< -1/2 (762< 88.9) N 18 <8-1/2 (2012 <2159) Factory Mutual E 13 -1/2 < 4 (88.9 < 101.6) 0 1 8.111 < 9 (2169 < 2284 F 14<4 -In (101.6<11431 P I9<9 -V2 (2286<24L31 KC Evaluation Service, Inc — 11ER - 1372 (fomler(y (CBO) G i 4.1/2 < S (1143 < 127.0) 0 19.18 < 10 t2413 <2$4A1 (inducing seismic loading conditions) H 15 < S -i/2 (127.0 < 139.7) R 110 < 11 (254.0 <279.4) Metro -Dade County — #01.0504.12 I I ¢1/2 < 6 (139.7 < 152.4) S 11 < 12 (279.4 < 304.8) 1 16 < 6-1/2 (152.4 < 165.11 _ T 112 < 13 (306.8 < 330,2) City of Los Angeles — #RR2748 'lamed rnmpd, * Ica enyinspectimt SBCCI Compliance Report — #9570 California State Fire Marshal Cal Trans nwRamset/Red Head' 1 -800- 899 -7890 39 11/03 RED HEAD' ANCHOR /NP S Submittal Information Trubolt Wedge Anchors Ultimate Tension and Shear Values (Lbs /kN) in Concrete* ANCHOR I INSTALLATION EMBEDMENT I ANCHOR ft = 2000 PSI (13.3 (APi) ( Pt = 4000 F41127b 61Pa) ! ft= 6000 PSI (41.4 61Pa) 019.. TORQUE DEPTH TYPE TENSION SHEAR TENSION SHEAR TENSION SHEAR In. (mm) Ft Um. (Nm) la. (mm) Um. (rn1 I tan (ItN) I Lbs mo I lbs. (kin I Lbs WO I LW. (3,N) 114 (6.4) 8 (10.8) 1 -1/8 (2861 1.180 (5.2) 1,400 (6.2) 1,780 (7.91 1,400 1611 1,900 (83) 1,400 (6.2) 1.15/16 (49.2) 2. (93) 1,680 (7.5) 3,300 (14.7) 1,680 (7S) 3100 (11.)) 1100 (2S) 2.1/8 (54.0) 7,260 (10.1) 1,680 (75) 3.300 (14.1) 1,680 (7.51 3,300 (14J) 1.680 (7.5) • 3/3 (9 .6) 25 (33.9) 1 - 112 (38.1) 1,680 (75) 2,320 (10.51 2140 (10.0) 2,620 (11.7) 2,840 (12.6) 3,160 .(14,1) 1 3 (7621 3.480 (153) 4.000 (17.81 53 (26.41 4,140 (18.4) 6,120 (211) 4300 (10.01 4 (101.6) 4,800 (21.4) 4,000 (17.8) 5,940 (264) 4,140 (18.4) 6 (27s.) 4,500 (70.0) 1/2 (12.7) 53 (7 1 -1/4 (572) 4,660 (20.7) 4,760 (21.2) 5,100 (22.7) 4.760 (211) 7,040 (313) 7.040 (313) 4 - 1 /8 (104.8) WS{ubaoay 4,660 (20.71 7,240 (3221 9,640 ( 7,240 (32.2) 10220 (48.1) 8,160 (36.31 6 1152.4) Y15-6 5340 (23.8) 7,240 (32.2) 9,640 (4291 7,240 (321) 10,820 (48.1) 8,160 (361) S8 (15.9) 90 (1210) 2 -3/4 (69.9) HoL,Oipped 6,580 (2931 7,120 (31.7) 7,180 (31.9) 7,120 (31.7) 9.720 (43.2) 9216 ( 5-18 (1302) 6,580 (293) 9,600 (427) 14,920 (66.4) 11,900 (52.9) 16.383 (729) 12.520 (557) 7-1/2 (190.5) Galvanized 7,060 (31.4) 9200 (42.7) 15,020 (668) 11,900 (529) 16,380 (72.9) 12.570 (55.7) 3/4 (19,1) 175 (237.3) 3 -1/4 (82.6) ca 7,120 (31.7) 10,120 (45.0) 10,340 (48.2) 13,720 (61.0) 13,300 (59.2) 15,980 (71,11 6-5/3 11683) WYl -304 S5. 10,980 ( 20.320 (90.41 17,700 (787) 23,740 (105.6) 20,260 (90.1) 23,740 (1054) 10 (254.0) at 10.980 (488) 20.320 190.41 17,880 (79.5) 23.740 (10161 23,580 (104 -9) 23,740 (109.6) 7/8 (22.21 250 039.0) 3.3/4 (953) 5WWd16S4 9320 (4231 13,160 (58.5) 14,740 (65.6) 16,580 (739) 17.420 (77.5) 19,160 (851) 6-1/4 (158.8) 14,660 (652) 20,880 (92.9) 20,940 (911) I8,800 (12811 24260 (108.4) 28,800 (1281) 8 (2032) 14,660 (65.2) 20,880 (9291 20.940 (93.1) 28,800 (12811 24260 (108.4) 28201) (1281) 1 (25.41 300 140611 4-1/2 (1143) 13,940 (62 .0) 16,080 (113) 20,180 (89.81 22.820 (101.51 21.180 (94,2) 24,480 (1089) 7-38 (18711 14.600 (64.91 23,680 (127.6) 23,980 (106.7) 37,940 (1683) 33,260 (140.0) 38,080 (169.4) 9-1/2 (241.3) 18,700 (831) 28230 (127.6) 26,540 (1181) 37,940 (1682) 33260 (1480) 38280 (169.4) 1.1/4 (318) I 500 (677.91 5.1/2 (119.7) 18,140 (80.7) 23.280 ( 26180 (1173) 29,460 (131.0) I 33.640 (1492) 33,760 (1503) 8 (2032) 27,340 (1216) 15.080 (156,0) 43,100 (1926) 44,260 (196.9) 45,540 (2072) 50560 024.9) • Almutle ulna ate bortvpma4toI lately ham Pa* by41as*ma. laid liturs. Trubolt Ultimate Tension and Shear Values (Lbs /kN) in Wedge Anchors Lightweight Concrete* ANCHOR INSTALLATION EMBEDMENT ANCHOR LUGHTWEIGHTCONCRETE LOWER PURE OF STEEL DECK WITH DIA. TORQUE DEPTH TYPE ft = 3000 PSI (20.7 NP8) UGHTWEIGHT CONCRETE ALL M. (mm) Ft. Lbs. (Nm) In, (mm) fc a 3000 PSI (20.7 MPa) TENSION • SHEAR TENSION SHEAR Lbs (kN) Lbs. (kN) Lbs (1W) I Lbs. (2.N) 3/3 (9.5) 25 (33.9) 1.1 /I (33.1) WSCarbonaz 2.120 (9.4) 3,720 (165) 1,500 (8.51 3,160 (14,1) 3 (76.2) WS-G 2.9 (13.1) 4,240 (18.9) 2,840 312.6) 4.000 (17.8) 1/2 (12.7) 55 (74.6) 2 -1/4 (57.2) Hot-0Ipped 3200 (16.0) 7,040 (3131 3.400 (15.11 5.380 (23.91 3 (76.2) 4,720 121.01 6220 09.4) 4,483 (19.9) 6220 (29.4) 4 (101.) I 6,920 (30.5) 4.800 (21.4) 6.440 (28.6) az 5/3 (15.9) 90 (122.01 3 (762) WW- WSS. 6,000 (26.71 9.240 141.1) 4,770 (21.0) 5,400 (243) 5 1127.01 5,90 (26.5) 9,280 141.3) 6,580 (29.31 9,140 (4011 3/4 (19.1) 175 (237.3) 3.1/4 (31.6) 1 01 7,160 (31.9) 12400 156.0) 5,340 (26.0) 8,380 (39.5) 5-1/4 (137.4) 1 SNtY-31653 $900 (39.6) 15.920 0081 7,040 (31.3) • Attosable yaws are use upon a 4 t I sA(ery WM Dhide b1 kA abobuole 1010 agues. 71Ramset/Red Head' 1 -800- 899 -7890 11/03 RED HEAD° - ANCHORING SYSTEM Submittal Information Trubolt Recommended Spacing and Edge Distance Wedge Anchors Requirements for Shear Loads* ANCHOR EMBEDMENT ANCHOR EDGE DISTANCE FIN. EDGE NUN. EDGE DISTANCE SPACING MIN. ALLOWABLE DIA. DEPTH TYPE REQUIRED TO DISTANO AT WHIM AT WHIM THE REQUIRED TO SPACING BETWEEN In. (mm) In. (mm) OBTAIN MAL THE LOAD FACTOR LOAD FACTOR OBTAIN MAL MOORS In. (mm) WONONG LOAD APPUED = .60 APPUED . .20 WORKING LOAD LOAD FACTOR In. (mm) In. (mm) In. (men) In. (nun) APPLIED a .40 111 (6.1) I -I/8 (28.61 2 (5081 I 1 -5/16 (3331 - - 3 -15/16 (14) 2 (491) 1•1-15/16 (49.1) 1 -15(16 (4921 1 (25.4) - 3 -7/8 '(98.9 &4) 1.15/16 (19.2) 319 (9.5) 1.1 /I (38.11 I-516 (66.71 1-3/4 (44.5) - - 5.1/4 (133.4) 2.5/8 (66.71 3 (76.2) WS -Carbon 3-3/4 (9531 3 (6.2) 1 -1/2 138.1) 6 (1514) 3 (76.2) 1/2 (72.7) 1 2.1/4 (57.2) ce 3 -15/16 (100.03 2-9/16 (65.1) - - 7-7/8 (200.0) 3.15/16 (1M0) I 4.1/8 (104.8) SYS6 5-3/16 (131.81 3-1/8 (79.4) 1.9/16 139.7) 6.3/16 (151.2) 3-1/8 179.4) 5/8 (15.9) . 2.3/4 (6951 31st 4ipped 4-13/16 (1222) 3 -1/8 (79.4) - - 9.5/8 (2443) 4 -13/16 (122.2) 5-1/8 (130.2) G4lr4aid 6-7/16 (1635) 3.7/8 (98,4) 1.15/16 (492) 7 -11/16 (195.3) 3-7/8 198.41 1/4 (19.1) 3-1/4 (82.61 5 -11/16 (144.5) 3-3/4 (953) - - 11 -3/8 (288.9) 5-11/16 (1443) 6-5/3 (1683) VYtY•304 SS 6 -5/16 (16031 S (127.0) - 2-1/2 (633) 9 -15/16 (252.4) 5 (127 .0) 7/8 (22.2) 3414 (9531 6-9/16 (1663) I 4-5716 (109.5) - - 13.1/8 (3314) 6.9/16 (1663) 81 m 6-1/4 1158 81/2 (215.9) 6-1/4 (15881 3 -1/8 (79.4) 12-1/2 (317.5) 6-1/4 (1588) 1 (25.4) 4-1/4 (108.0) SWW-)765.S. 7 (2000) 5.1/8 (130.2) - - 15-3/4 (400.1) 7-7/8 (200.0) 7.318 (181.31 10-1/16 (255.6) 7.3/8 (187.3) 3 (93.1) 14.3/4 (374.7) 7.3/8 (1873) I -1/4 (31.8) 5-1/2 (13931 I 9-5/3 (24431 ) 64/4 (1 588) - - 19-1/4 (400 .0) 9-5/8 (24431 8 (2032) _ 11-7/16 (290.5) 1 8 (2032) 4 (101.6) , 16 (406.4) 8 (203.2) • Sd.m -0+nd edge dames dug be akedel 690 75 oho main m was Is qICTIVA a la ceemee. Law ed9paliots airy be used for ntennedba wag anti edge Comm Trubol t Recommended Spacing and Edge Distance Wedge Anchors Requirements for Tension Loads* ANCHOR EMBEDMENT ANCHOR EDGE DISTANCE -am. ALLOWABLI SPACING REQUIRED ' MIN. ALLOWABLE In. (nun) In. (mm) TYPE OBTAIN MAX. S WHICH THE WAD 03081.0816 (DAD THE LOAD FACTOR WORKING LOAD FACTOR APPUED a.65 In. (mm) APPLIED =.70 In. (ram) la. (mm) In. (mm) 1/4 (6.4) 1.18 (28.6) 2 (50.8) I (25.4) 3 -15/16 (1000) 2 (5081 1.15/16 ( 1-15/16 (49.2) 1 (25.4) 3.718 (941 1- 15/16 (49 21 2 (54.0) 1 - 5/8 (413) 13/16 (20.6) 3 -3/16 (810) 1.518 (413) 38 (93) 1 -Ill (381) 2-5/8 166,71 1 -5116 (333) 5-1/4 (133.4) 2-5/8 (66.71 3 (76.2) 3 (76.21 1 -1/2 (38.1) 6 (152.4) 3 (76.2) 4 (101.6) 3 (76.1) 1.1(2 (38.1) 6 (152.4) 3 (76.2) 1/2 (11.7) 2-1/4 (57.2) 3.15116 (100,01 2 (50.8) 7 -78 (200.0) 3.15116 (100A) 4.18 (104.81 WS -Urban at 3.18 (79.4) 1 -9/16 (39.7) 6-3/16 (157.2) 3.3/8 (79.4) 6 (152.41 195-6 4-1/2 (1143) 2-1/4 (57.2) 9 (223) 4-1/2 01431 5/8 (15.91 2 -3/4 (69.9) H41 -Ikp44d 4.13/16 (1222) 2 -7/16 (61.9) 9-5/8 1244.5) 4.1346 (1222) 5.18 (130.2) Gahvraxd 3. 118 (58-4) 1 -15/16 (494 14/16 (7953) 3-7/3 (98,4) 7-1/2 (1905) 5-5/8 (1 2.13/16 (11.4) 11 - 1/4 (2818) 5-5/8 (1429) 3/4 (19.1) 3.1/4 (82.6) 5-11/16 (144,5) 1 - 718 (73.0) 11 -3/3 (1889) 5.11 /16 (144.5) 6-5/13 (1683) 5 027.01 2-1/2 (63.5) 9.15/16 (252.41 S (177.0) 70 (254.0) 41 7.117 (1905) 3 -3/4 (95.3) 15 (381.0) 7-1/2 (1905) 78 (22.2) 3-3/4 (953) SWW 31653. 6-9/16 (166,71 3-5/16 (84.1) 13.18 (333.4) 6-9/16 (166.7) 6-1/4 (12,8) 6-1/4 (1588) 3.18 (79.4) 12 -1/2 (317,5) 6-1/4 (1589) 8 (203.2) 6 (152.4) 3 (76.2) 12 (3043) 6 (152.4) 1 125.41 1.112 (II43) 7.78 (2O0) 3.15/16 1100.0) 15-314 (400.11 7 - 718 (100.01 7.3/8 (1873) 7 - 318 1187.31 3 - It/7 6 (93.7) 14.3/4 (3742) 7.318 (187.31 9.1/2 (241.31 , 7.1/8 1181.01 3 (90.5) 14 (362.01 741/8 (181.0) 1 -1/4 131.8) 5-1/2 (139.71 9-5/8 (2445) 4-13/16 112211 19-1/4 (469.0) 9.5/8 (1445) 6 (203.2) 8 1203 2) 4 1101.61 16 (406.4) 8 (203.2) • Sturm.) sns edge d a u s u s Pail be asses tn0n anann *te . snood te7ntregd cmmete two eRerodetemm.l be used lot mranlebns wag and edge de anoes Combined Shear and Tension Loading-for Trubok Anchors Allowable loads for andwrs subjected to combined shear and tension forces are determined by the following equatlox (Fs/Ptl " NOW 1" s Ps = Applied tension load Ys = Applied shear load Pt a Allowable tension load Vt = Allowable shear load 1 ITltrtl7Ramset/Red Hea 7 -800- 899 -7890 41 11/03 HDI -P: Item No.: 00243554 - hilti.com Page 1 of 1 Catalog Anchoring Systems Metal Anchors Internally Threaded Anchors HDI Drop -In Anchor HDI -P Flush Drop -In Anchor HDI - P: Item No.: 00243554 Click to enlarge !Technical Data [Anchor length 3/4 In. Drill bit diameter 1/2 in. 'Material composition Carbon steel with zinc plating Metal composition Carbon steel I Base materials Concrete block (solid), Concrete deck (hollow), Stone (l Additional product Short embedment for Information precast hollow slabs Applications - Reliable fastenings in hollow core panels , precast plar slabs Hilts. Outperform. Outlast. Hlltl = registered trademark of Hilti Corp., FL -9494 Schaan, Prindpality of Uechtensteln @ 2001 - 2006, Right of technical and programme changes reserved, S.E. & 0. • http:// www. hil ti.com/holcom/modules /prcadprca fuse jsp ?RANGE OID =10772 4/26/2006 S I D E W I N D E RS TM 1I0 RIZ \IAL M0UNI • Mood Nut Driver 1/4" 8018957 4016 SWG 100 1/4 X 1 25 9.38 125 Use #t4S1n► Nut Dduer 1/4' 8019957 300 SWG 200 1/4 X 2 25 10.00 125 t for Ski:mi deisand 1/2" Rod Semmys i Ix 3/8' 8020957 18 SWG 10 1/4 X 1 25 7.50 125 3/8' 8021957 19 SWG 20 1/4 X 2 25 8.75 125 3/8" 8022925 26 SWG 25- 380 3/8 X 2 -1/2 3/8' 8023925 25 25 12.81 125 SWG 30 1/4 X 3 25 10.63 125 3/8' 8050957 39 Iteel SWD 10 1/4-14 X 1 25 7.50 125 Pert 08114910 3/8" 8051957 40 SWD 15 1/4 -14X 1 -1/2 25 9.38 125 I A . tem It t01 3/8" 8052957 41 SWD 20 1/4-14 X 2 25 8.13 125 3/8" 8053957 42 SWD 516 5/16 -18 X 1 -1/4 25 8.75 125 iSt' 3/8" 8054957 46 SWDR 1 -1/2' 1/4-20 X 1 -1/2 25 9.06 125 gi• 3/8" 8055957 43 SWDR 1" 1/4-20 X 1 25 8.75 125 4 3/8' 8056957 44 SWDR 516 5/16 -18 X 1 -1/4 25 10.31 125 3/8' 8057957 45 SWT 15 12 -24 X 1 -1/2 25 7.81 125 loncrete 1/4' 8062957 1900 SWC 200 5/16 X 1 -1/2 25 9.38 125 -r 3/8' 8061957 65 SWC 20 5/16 X 1 -1/2 25 9.38 125 • Most Items Available in Stainless Steel NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! * Use with 3/8" Rod Sammy Swivel Head"" Approvals Part # item # Model Box Weight Case Descriptions Qty. (per 125) Qty • U.S. Patent No • 17 deflection from vertical 1 6.443.660 • Acoomrrrodaltes up to 8139957 4702 SH -GST 20 1/4 x 2 25 9.38 125 3-1/2 X 12 pitdi roof gi 8140957 4703 SH-GST 22SS 1/4 x 2 25 9.38 125 • 1 5 8141957 4704 SH -GST 30 1/4 x 3 25 10.94 125 Also available In stainless steel 111.111.111111.11111111.111.. 4 8142957 4705 SH-GST 30SS 1/4 x 3 25 10.94 125 • Use #14 Nut Driver (blade) ii‘ 8137957 4700 SH -0STR 1 1/4-20 x 1 25 9.38 125 - li 8138957 4701 SH -0STR 1 - SS 1/4-20 x 1 25 9.38 125 mreaa Rod Dt y Patent Pending SAMMY X-PRESSTM . ,v_ Thin $ �. - ems • :• App s Steel Part # Item* Model � Weight CasE Oe Ga. ' Dep� Qty. (per 125) Qty. . �' 1 I C ' 22 -20 8150922 500 XP 20 1/4-20 x 1 -1/8 Sammy X -Press 20 25 10.3 125 Q" 1/4 -20 x 1 -1/8 -s - �-- r 18-16 8153922 503 XP 35 Sammy X -Press 35 25 10.3 125 uninstaIIed - IX I r Sammy X -Press It SAAIMIla; • t 8151910 501 XPI 1 1.02 1 Installation Tool REINS TM (Kit includes: Sleeve. Bit Receiver, Hex Wrench. and 25/64' Drill DO Installed 8152910 502 XPDB 25/64" Drill Bit 1 0.14 1 DIVISION 13 13910 BASIC FIRE SUPPRESSION MATERIALS & METHODS The following information FL FlexHead® Industries with the permission of Reed INDUSTRIES "TL - Commercial . Construction Data. Holliston, MA ' f Sprinkler 'e Founded in 1992 FlexHead Industries is dedicated to Connection providing safe, leading edge technologies that pro- ; s�:,, mote increased installation and maintenance of auto- 9y ' 2- z__ matic slinkier systems. � ';` Product Description & Applications Flexhead manufactures flexible stainless steel hose . assemblies that connect sprinkler heads to the branch Imes. These systems install In � - ° " " '' ' - "�' "r, = -# Y quarter of the time of hard pipe ormovers, and sprinkler heads can be easily ` '' " *'Alb,. r relocated, inspected and maintained. With no rigid "r �e�rJ�' F-. joints between the branch line and the head, the flexi �� • ble connection is Impervious to building motion, even t - ' � n in seismically active areas. It remains completely water- ,- r - tight even under the most ngorous conditions. ; ; ;,; - << � ., With any contractor installed sprinkler head of �'� Choke, this pressure /leak tested system is available in 2'-6' 0.6 -1.8m s ' ..Ti ( ) hose lengths, making it ideal for any.. commercial, institutional, duct or deanroom applica- ;n. ;, lion. In addition FlexHead both minimbes the cost and ll simplifies the labor required to bnng unsprinklered build- ( r' ings up to code. It installs In minutes, even in the most restrictive of spaces. Features & Advantages Exhaust Duct FlexHead sprinkler connections provide engineers, !I Sprinkler r I architects, contractors and building owners with a level S p of flexibility previously unavailable, including: Connection . - . a • Reduced labor costs and callbacks — � • Expedites retrofitting of buildings with confined /„..,,.,,„- "— "•� spaces / • Predictable Installation - eliminates bidding problems and scheduling delays • Fast -track construction for rapid occupancy • Compatible with any FM /UL approved sprinkler head MEWED • 100% leak- tested system • Industnal grade, all welded, no 0-ring construction • Adjustable height and sprinkler alignment / center -of - °' °W file uniformity • No additional hangers required • Compatible with BlazeMaster" Fire Sprinkler Systems t Properties & Performance t r ' • - • All products meet NFPA 13 Guidelines P • � i 1.7- ' ' . .ins _ titutronal - • Commercial products are approved for use with f 1, light, medium and heavy load grids (ASTM C 635, f 1 - Spr C 636) /� • All products are rated up to 175 or 300 psi (12 or 2067 i �' • • - CO neat , . ` • kPa) products International Building Code compii- oducts are Inter . " � i ant for sprinklers installed in seismic design classes C, . D.E and F 1 • Commercial product Is FM approved and UL listed for 1' suspended ceiling and gypsum board ceiling instal - lotions _ Construction, Materials & Finishes �� �' Every FlexHead sprinkler connection comes complete with the flexible hose and attachment bracket. Construction, Materials & Finishes SPEC WPC. FIRST CATAL 8W-829-6975 or 508- 893 -95% Fax 508-893-6020 =Ia Q- scowl. n °c Ema l: info@flexhead corn WW flexhead.com @ www ReedFirstSource.com 6icreMasrer s o registered irodemark of Noveon IP Hoktngs Corp. C66' Reoa Construction Oar, an r?ghtsRasen.ea • SPEC ® BASIC FIRE SUPPRESSION MATERIALS & METHODS 13910 . . , FlexHead Industries, Inc. F I.Ex ® •Flexible changes design in floor provior des occupancy versatility for iD plan •Compat with any FM /UL approved sprinkler head I N D U S T R I E S E L I •100% leak tested system 'Industrial grade, all welded, no 0 -ring con- struction, uses all stainless steel components - Commercial 1. Product Name ',- 'Adjustable height and sprinkler alignment/ ,s FlexHead Commercial Sprinkler Connections center-of-tile uniformity Sprinkler t •Rated up to 300 psi (2066 kPa) with no ' Connection 2. Manufacturer additional hangers required ' r."-- "4:e. FlexHead Industries, Inc. 'Easy friction loss /water pressure calculations 56 Lowland St. - ` ° = ;J Holliston, MA 01746 'Multipart bracket provides uniformity with any w.., suspended or gypsum board ceiling system (800) 829-6975 14 (508) 893 -9596 'Compatible with BlazeMaster m Fire Sprinkler _ Systems f Fax (508) 893 -6020 � 'Approved for use in suspended ceiling sys- E- � - E -mail: sales @FlexHead.com terns with Ilght, medium and heavy , www.flexhead corn load grids (ASTM C635, C636) - wl► ►`:r r r r +t •True -bore 1" (25.4 mm) internal corrugated - r ' ." .4 3. Product Description hose diameter, which produces friction loss --- �, - .y,''=.- ' ..- BASIC USE values similar to hard pipe armovers Suspended ceiling installation FlexHead manufactures flexible stainless steel •Fully braided hose provides excellent pro - hose assemblies and a bracketing system that tection against pressure surges COMPOSITION & MATERIALS connect sprinkler heads to the branch lines .2003 IBC and SEI /ASCE 7 -02 compliant Every FlexHead connection comes complete These systems install in a quarter of the time of for sprinklers installed in seismic design with the flexible hose and attachment brook- hard pipe armovers, allowing for rapid Instal- classes C and D /E /F et. Each connection is made from 100% facto- lotion or relocation of sprinkler heads in sus- ry tested Type 304 stainless steel. The hose nip - pended ceilings. pies are also 304 stainless steel and are fully Each FlexHead unit comes with a mounting ® welded using a proprietary welding process bracket and a 1- piece, leak tested sprinkler . �r (no 0- rings). FlexHead is leak tested to 175 psi drop. The mounting bracket is compatible (1205 kPa). It has burst pressure of over 2000 with any suspended or gypsum board ceiling SYSTEM COMPATIBLE psi (13,780 kPa). system. With any contractor installed sprinkler head " of choice, this pressure /leak tested system is available in 2' - 6' (0.6 - 1 8 m) hose lengths, , _„ making it ideal for any commercial applica Lion In addition, FlexHead both minimizes the r ,'• Y' g cost and simplifies the labor required to bring . � . !. - ,� * ,, unsprin buildings up to code. It installs in ', ° i , - ' � , minutes, even in the most restrictive of spaces. fe ,�' All FlexHead commercial sprinkler connec � ` tions are Factory Mutual ry (FM) approved and ma x _ UL listed and are manufactured in an FM /UL . audited facility. ','� BENEFITS �, ti • Reduced labor costs and callbacks r , ' Expedites retrofitting buildings with con - - - , `'e ;`'mow fined spaces x ,� .�, Predictable installation eliminates bidding - "_ ' �° g - problems and scheduling delays ; x � ° Fast-track anc construction for rapid building : fi �`� w r y 7 m Gypsum board ceiling installation SPEC 04 74 c,,r MANU- SPEC " ..m '? t 'oc x Rai.! E411,7,4 !rc ;' ;13r, irrt SPEC 1, ,r ' • ^ -� or 4 - , .+• .,u�,rp , el.,* �J Ji , e.:Cra, .. .L`?fiv. y1::",t''um .nd3,,,N!t. 1 6, .,:!he, 5•2 , .nurce- :lbr ; , 2:L r!h ) M ��� , �'J "CCY �,C , 66:1 �C� !i'IC!,. _ 42 , , ', ber..6U SPEC ® BASIC FIRE SUPPRESSION MATERIALS & METHODS 13910 , FlexHead Industries, Inc. The bracket system is made from galva- nized sheet metal and is approved and com- patible for use with light, medium and heavy, load grids (ASTM C635, C636) or gypsum __ board ceiling systems, 1 ; SIZES ' ��� :0 „w ., FlexHead is available in 2', 3', 4', 5' or 6' (0.6, 0.9, v,i 1.2, 1.5 or 1.8 m) hose lengths. ±�s``° 4. Technical Data '' '° APPLICABLE STANDARDS _ American Society of Civil Engineers (ASCE) aK SEI /ASCE 7 -02, Section 9.6 Architectural ' '”' F' ``"-"` . 5 Mechanical, and Electrical Components and Systems ASTM International "* • ASTM C635 Standard Specification for the ,w Manufacture, Performance, and Testing of � -� Metal Suspension Systems for Acoustical Tile � , and Lay -in Panel Ceilings ASTM C636 Standard Practice for Suspended ceiling installation in a confined space Installation of Metal Ceiling Suspension Underwriters Laboratories, Inc. (UL) - UL 2443 BUILDING CODES Systems for Acoustical Tile and Lay -In Panels Standard for Flexible Sprinkler Hose with Current data on building code requirements Ceilings & Interior Systems Construction Fittings for Fire Protection Service and product compliance may be obtained Association (CISCA) PHYSICAL /CHEMICAL PROPERTIES from the manufacturer's technical support • Recommendations for Direct -Hung Acoustical Test reports are available to design proles specialists. Installation must comply with the Tile and Lay -In Panel Ceilings, 2002 Seismic sionals upon request. requirements of applicable local, state and Zones 0 2 national code jurisdictions. • Guidelines for Seismic Restraint Direct Hung 5. Installation Suspended Ceiling Assemblies, 2002, Seismic 6. Availability & Cost Zones 3 and 4 PREPARATORY WORK International Code Council (ICC) Installation should only be performed by qual- AVAILABILITY • ICC International Building Code (IBC), 2003 - ified and licensed technicians in the fire pro- For information on product availability or to Sections 803.9 Acoustical Ceiling Systems; tection field. Consult NFPA, FM, UL and state locate an authorized FlexHead distributor, 1621 Architectural, Mechanical, and and local guidelines prior to installation, contact FlexHead Industries, Inc, Electrical Component Seismic Design METHODS COST Requirements; and 1622 Non - building Each FlexHead ceiling sprinkler connection Budget installed cost information may be Structural Seismic Design Requirements includes a multipart mounting bracket and a obtained from the manufacturer upon •ICC Uniform Building Code (UBC), 1997 - 1- piece, leak tested FlexHead sprinkler drop. request. Standard 25 -2 Metal Suspension Systems for Attach the bracket to the t -bar ceiling grid; Acoustical Tile and for Lay -In Panel Ceilings then attach the FlexHead sprinkler to the sub- 7• Warranty FM Global Technologies LLC (FM) - FM main Secure the sprinkler to the bracket Test FlexHead Industries, Inc., warrants that its Class Number 1637 Approval Standard for installation of sprinkler system for any leaks products will be free from defects in materials FlexibleSprinkler Hose w/Threaded End Fittings Per NFPA guidelines, and workmanship under normal conditions of use and service for a period of 1 year from P RECAUTIONS National Fire Protection Association (NFPA) date of sale. The obligation under this warran- •NFPA 13 Standard for the Installation of Consult the manufacturer's installation instruc- ty is limited to repairing or replacing any prod - Sprinkler Systems tions for complete installation information, uct that is returned with transportation • NFPA 13D Standard for the Installation of Failure to follow the cited instructions may charges prepaid within 1 year after the date Sprinkler Systems in One- and Two - Family cause personal injury, During maintenance or of original sale and that an examination by Dwellings and Manufactured Homes inspection of FlexHead product, the facility FlexHead shows to their satisfaction to have •NFPA 13R Standard for the Installation of fire protection system must be inactive. Do been defective In materials or workmanship, Sprinkler Systems in Residential Occupancies not attempt relocation or maintenance of under normal conditions of use and service up to and Including Four Stories in Height FlexHead product while fire protections sys- The decision as to whether to repair or to tern is live. ,',' - iFcr Q4 TA - ° cnC 4 !rL- iFEC'' .ve c-val 6C F,;;d Y R +.as ch &vrr i:. :46 'sr ^. • ,,, �Cc,, ,.c. ,- $ tti,ri ,fl,, , Ths , e ar a 3...n, , .. ^:9.; :3, M, „u n.., ,lccrom pan c h c c, c !.r ,. •• ^5 -. C ! , , c; ^,1n l MSG4i1!(., - cU;liti:... ,.CL;, . [��'V; 'cnT CN�r , ^X`�iC. ^;'d,0 4 1 7.;j ^.:19,.c„ • SPEC ® BASIC FIRE SUPPRESSION MATERIALS & METHODS 13910 .."' FlexHead Industries, Inc. replace any product shall be made by FlexHead Industries, and any repair shall be made at their facility. Contact the manufac- turer for complete limited warranty details. 8. Maintenance Contact the manufacturer for complete maintenance information, 9. Technical Services Design assistance and technical support are available upon request from the manufactur- er's trained staff. 10. Filing Systems MANU - SPEC"" First Source CAD Additional product information is available from the manufacturer upon request. • FGG /BMR' System Compatible indicates this product has been tested and Is monitored on an ongoing basis to assure chemical compatibility with FlowGuard GoldT'". BlazeMasterim, and Corzanw pipe and fittings. FGG /BMT."FlowGuard Gold7oBlazeMasterrY and Corzanw are registered trademarks of Noveon IP Holdings Corp. ` J SPEC-DAT%, a, M4UU SPEC' ar. rt,gOrt hodemo u of Feed EA emer Inc, The ten one SPEC-DATA format canroms to Mee xllton,l ; Ate. of Tnr Corsfi -chop Soec.tkic■cns rn•hnrts ono n urea ts;Tlt TheP per,. -wort. tna mcnL'fo :lure, It reipcncb'e frAt tech-moor cccu,Ict' C2tro Fuec :,CfisrIucAnn D.2n, ae RF7nh Bulletin 136 Rev.M ReIiabI ® Model Fl FR co M odel Fl FR Recessed Quick Response Sprinklers CD Model F1 FR Sprinkler Types Standard Upright or _._, Standard Pnent ' r•' (1'`.71 �`�` .- � Conventional � ;�, Vertical Sidewall " Horizontal Sidewalk' ! } - HSW 1 Deflector Model F1 FR Recessed Sprinkler Types =: Recessed Pendent Recessed Horizontal Sidewall Upright Pendent - HSW 1 Deflector Listings & Approvals ` ` , 1. Listed by Underwriters Laboratories, Inc. (UL) 71 - 2. Listed by Underwriters' Laboratories of Canada (ULC) 3. Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) • • „..:_,,, 1 , - ._., t.'. 5. NYC BS &A No. 587 -75 -SA 6. Meets MIL -S-901 C and MIL -STD 167 -1 �w `.. 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258 -93 -E `. - UL Listing Category Vertical Sidewall Conventional Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV ,,,„ I, Patents: US Patent No 6,374,920 Applies to , � 11. : j} R Model Fl FR Vertical Sidewall Sprinklers. YY p Product Description Horizontal Sidewall Recessed Pendent Reliable Models F1FR and F1FR Recessed Sprinklers are HSW 1 Deflector (Model FP Shown) I quick response sprinklers which combine the durability of a standard spnnkler with the attractive low profile of a decorative sprinkler. pands, forcing the bubble smaller and smaller as the liquid The Models Fl FR and Fl FR Recessed automatic sprinklers pressure increases. Continued heating forces the liquid to utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are push out against the bulb, causing the glass to shatter, opening five to ten times faster than standard response sprinklers. This the waterway and allowing the deflector to distrib quick response enables the Model F1FR and F1FR Recessed ute the discharging water. spnnklers to apply water to a fire much faster than standard Application sprinklers of the same temperature rating. Quick response sprinklers are used in fixed fire protec- The glass bulb consists of an accurately controlled amount tion systems: Wet, Dry, Deluge or Preaction. Care must be of special fluid hermetically sealed inside a precisely manu- exercised that the orifice size, temperature rating, deflector . factured glass capsule. This glass bulb is specially con- style and sprinkler type are in accordance with the latest structed to provide fast thermal response. The balance of published standards of the National Fire Protection Asso- parts are made of brass, copper and beryllium nickel. cation or the approving Authority Having Jurisdiction. At normal temperatures, the glass bulb contains the fluid Quick response sprinklers are intended for installation as in both the liquid and vapor phases. The vapor phase can specified in NFPA 13. Quick response sprinklers and stan- be seen as a small bubble As heat is applied, the liquid ex- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench - Installation Data: Sprinkler Type K Factor Sprinkler Identification Sprinkler Aproval Standard-Upright (SSU) and Pendent (SSP) Spr Number (SIN) Deflectors Marked to Indicate Position US I Metric Height Or SSU SSP X" (15mm) Standard Onfice with A" NPT (RYA Thread 56 1 80 2 2' (56mm) 1,2,3,4,5,6,7 R3625 R3615 '4 (20mm) Large Orifice with %" NPT (R3/4)Thread 80 115 2.3" (58mm) 1,2,3,4,7,8 R3622 R3612 7,E" (17mm) Small Orifice with);" NPT (RX) Thread 4 2 60 22' (56mm) 1.2,8 R3623 R3613 %" (10mm) Small Orifice with f NPT (RY) Thread 28 40 2.2' (56mm) 1,2,8 R3621 R3611 10mm Orifice XLH with RX," Thread 4.2 60 56mm 4,6,7 R3624 R3614 Conventional-Install in Upnght or Pendent Position 10mm Orifice XLH with RX Thread 4 2 60 56mm — R3674 15mm Standard Orifice with 2 NPT (RX) Thread 56 80 56mm 4,6,7 R3675 20mm Large Onfice with 3/4' NPT(R 80 115 58mm 4,7 R3672 , -...• . ''' , •- • -='-- " ' s , _....... ... , ... ; .1,. t.i....-.._-•-.::. I i i • ki. i i t 0 3' ‘'''• - 4 ...A4 .....t _ ..... ......... .,. .. ...„- ... _ Upright Pendent Conventional Model Fl FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Approval Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) A" (15m m) X," N1F (R1/2) 56 80 2.2" (56rnm) 1,2,3,4,5,7,8 R3615 1 %2" ( x," N P T ( R I, ) 8.0 115 23" (58mm) 1,2,3,8 R3612 ;1 (11mm) / NPT (R1/2) 4 2 60 2.2" (56mm) 1,2,8 R3613 X," (10mm) X" NPT (R1/2) 2.8 40 2.2" (56mrn) 1,2,8 R3611 10mm RX, 4.2 60 56mm 4,7 R3614 (I) Refer to escutcheon data table for approvals and dimensions 5/8" 0 [61,7 2n7r — ..-i ...-- .-40LE IM CEILING , :5/Iii" CM ...-- 1 7 --..." ha 2 5/76" D 7 ....II I . 1 -- m__..-- ,_ .. :/2" REDutTP I 7 , 1 I I I ....-- 1 - X '72" TURN CO(L■R I 'T , UNTIL rr,-,r .40.m5 SPM. LER 1 weEkt'h BOSS • I \ / I \ 1 L-c-,---____—,4 I ' I . I • ' I -'--- - I I 1 I ... -.7. - - -- - -----. _ 1 1 1 rA_ 0", 70"' CEIL,NC, I , 4LAVSeaLle ' ' CEIUNG aviICKW i . - !f 03,-- \i j -1 , 1 3 i 'I 03 Vel I FACE OF F7T77,.C; 71) FA'.7S 0; CE • 1 1 1 r — I ie• N \‘..tx.:, , ; ' ' 1 , • ,....„.„,,u, • ,, 1 I ) 1 Ar I , ,, "1,72_,_7 2 2/32' 0A — 4'540'P 4'540'P - - - — 1: ...--- I I F' ES':V/CHE'Y'i 0ATA 'AR i , OP AF.P0 5 ;AD DAIENS ( r) REFER '0 Fe EECtilrvEL'S 04;4 r-re.. e 'CI' AP /AL 5 INC 0 UENSC VS 2. Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench • Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: K Factor Sprinkler Approval Nominal Thread Sprinkler Orifice Size US Metric Height Organizations identification Number (SIN) Number (SIN) 'h_" %z" NPT (R'h) 5 6 80 2.2" (56mm) 1, 2, 3, 6, 8 R3685 15mm 'h" NPT (R' /z) 5.6 80 2.2" (56mm) 4 (1) (') LPC Approval is for Pendent position only. Orientation Deflector to Ceiling Dimension (Min. - Max.) Upright 4" - 12" (102mm - 305mm) Pendent 6" - 12" (152mm - 305mm) Vertical Sidewall I US Patent No. 6,374,920 Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: K Factor Approval Organizations and Type of Approval Sprinkler Nominal Thread Sprinkler identification Light Ordinary Number (SIN) Orifice Size US Metric Length Hazard Hazard y" (15mm) y" NPT(R'h) 5.6 80 2.63" (67mm) _ 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. ! 6FG 74 r YZZl1�� __— JC! t - L FACE Or FITTING TO -- -0.- c - - r � / -1 A : , WALL DIMENSION I �- -■ r 1 /e" MN P t I /, �` „ \�4 [5 72mmf - 2 1/4" HOLE TEA i ! /B [sr emmj a -_b. r t { L � . t t i e ■ ) d I { [J7mrn) 1101.Emm- 1_a.4mm) S " ; l i! ' CE2ING TO b j ' + 1 '. ,t I/1'" REDUCER 7 h. DEFLECTOR 7 ;5)6" Horizontal Sidewall Mg 2ninq •1 h. . ' _ �� : 17/32" D:a. [72 2rnm; • / ,� " � — TURN COLL4R UNTIL - -- TISI -T AGAINST SPRINKLER ' WRENCI, SOSS ""'.1 - ALiJUSf ML NI (I) (') RFFEN T2 ESCU OA r4 TAELC POP APPRQ ✓AL:: AND DIMENSION'S. 3. - Installation Quick response sprinklers are intended for installation as cleaning fluids. Remove dust by using a soft brush or gen- specified in NFPA 13. Quick response sprinklers and stan- tie vacuuming. Remove any sprinkler which has been . dard response sprinklers should not be intermixed. painted (other than factory applied) or damaged in any The Model Fl FR Recessed Quick Response Sprinklers are to way. A stock of spare sprinklers should be maintained to be installed as shown. The Model Fl or F2 Escutcheons illus- allow quick replacement of damaged or operated sprin- trated are the only recessed escutcheons to be used with the klers. Prior to installation, sprinklers should be maintained Model Fl FR Sprinklers. The use of any other recessed escutch- in the original cartons and packaging until used to mini - eon will void all approvals and negate all warranties. mize the potential for damage to sprinklers that would When installing Model Fl FR Sprinklers, use the Model D Spnn- cause improper operation or non - operation. kler Wrench. When installing Model F1FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any Sprinkler Types other type of wrench may damage these spnnklers. Glass bulb sprinklers have orange bulb protectors to minimize Standa Uprigh bulb damage during shipping, handling and installation. RE Standard Pendent MOVE THIS PROTECTION AT THE TIME THE SPRINKLER Conventional SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- Sidewall (Vertical. Horizontal HSW1) moval of the protectors before this time may leave the bulb vul- Recessed Pendent nerable to damage. RASCO wrenches are designed to install Recessed Horizontal Sidewall HSW1 sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Finishes " R1 TO REMOVE THE PROTECTORS. Standard Finishes Temperature Ratings Sprinkler c n Sprinkler Bronze Brass Classification Temperature Max. Ambient Bulb Chrome Plated Chrome Plated 131 >C ° Temp. Color White Polyester Coated Wnite Painted 13) Ordinary 57 135 100°F (an) Orange Special Application Finishes O to 68 155 1CXFF (38"C) Red Sprinkler Escutcheon 79 175 150°F (66°C) Yellow Intermediate 9l3 200 150°F (66'C) Green B Brass Bright Brass High (1) 141 286 225°F(10TC) Blue Black Plated Black Plated (1) Not available for recessed sprinklers Black Paint Black Paint Off White Off White Escutcheon Data Satin Chrome Satin Chrome Escutcheon .. Faoe Fdtlng ti) Other finishes and colors are available on special order Model Approvals Adjustment fo Ce0lrvor Consult the factory for details. Wa0 Dimension 12) FM Approvals Is limited to bronze and brass, chrome or black 1/2" plated finishes only. Fl 1,Z4,8 Max Recess (38 1mm) 3;a' -'3i 13) FP Push -on /Thread -off escutcheon Min Recess X" (5mm -24mm) (19 1mm) 1y Ordering Information F2 1,2.3,4,5,7,8 Max Recess (38.1 mm) y,," - 7, Specify: Min Recess 'X," (5mm -17mm) 1. Sprinkler Model (24mm) 2. Sprinkler Type FP 1.2 Max Recessed (1 Y18" m) 1y," (38 1mm) 3. Orifice Size Thread-off 1,2 Min Recessed Vie 1 "(2;4mm) 4. Deflector Type (24mm) 5. Temperature Rating No Dimensional Figure for FP 6. Sprinkler Finish Maintenance 7. Escutcheon Type The Models F1FR and F1FR Recessed Sprinklers 8. Escutcheon Finish (where applicable) should be inspected quarterly and the sprinkler system Note: When Model F1FR Recessed sprinklers are maintained in accordance with NFPA 25. Do not clean ordered, the sprinklers and escutcheons are packaged sprinklers with soap and water, ammonia or any other separately. The equipment presented in this bulletin Is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association. Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances wnenever applicable Products manufactured and distributed by Reliable have been protecting life and property for over 80 years and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United Slates. Canada and foreign countries Manufactured by Reliabid T he Reliable Automatic Sprinkler Co., Inc. (800 - 6 058 Sales Offices 'ePef Sales Fax (914)668 -3470 Corporate Offices Revision lines indicate updated or new data www rel aolespnniiler com Internet Address SG Printed :n U S A 7/05 PM9999970027 BuI letin 131 Rev. H !tell Model GFR m able Model GFR Recessed g Sprinkle Quick Response rs at Model GFR Sprinkler Types UL ListingCategory Stan dard U rl ht Sprin klers, Au to matic & Open P g Quick Re sponse Sprin kler Standard Pendent UL Guide Number Horizontal Sidewall VNIV HSW1 Deflector Product Description Intermediate Level U ri ht Reliable Models GFR and GFR Recessed Sprinklers are P 9 Quick Response fusible sol der type auto matic sprin klers. Intermediate Level Pendent These sprin klers have dem on strated re sponse times in Conventional laboratory tests which are five times faster than standard re sponse sprinklers. Model GFR Recessed This quick response enables the Models GFR and GFR Re cessed Sprin klers to ap ply wa ter to a fire much Sprinkler Types faster than standard response sprinklers of the same temperaturerating. Recessed Pendent Application Recessed Horizontal Sidewall Quick re sponse sprin klers are used in fixed fire pro tec- HSW1 Deflector tion sys terns: Wet, Dry, De lute or Preaction. Care must be ex ercised thattheor i fice size, tern pera ture rating, de Approvals flec tor style and sprin klerspac ingg are in accordance with 1. Un der writers Laboratories, Inc. (UL) the latest published standards otthe National Fire Pro tee 2. Underwriters' Laboratories of Can ada(ULC) tion As so ci a tionorthe ap proving Author ity Hav ing Ju ris 3. NYC BS &A No. 587 -75 -SA diction. Quick response sprinklers are intended for 6. MIL- S -901C and MIL- STD -167 -1 standard area coverageand stan dardwa ter den sitiesas 7. NYC MEA 258 -93 -E specified in NFPA 13. Quick response sprinklers and stan dard re sponse sprin klers should not be in ter mixed. ' 3,..,:Alk- '..)' k r. ,. ,! F i 31v , Upright Pendent Intermediate Intermediate Level Pen dent Level Up right SmallOrificeUpright • , r e �� S' '"X3.---": Conventional HorizontalSidewall Recessed Recessed Pendent HSW 1 Deflector HorizontalSidewall HSW 1 Deflector The Re liableAu tomaticSprin klerCo., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model G FR Quick Response Upright, Pen dent& Con ven tional Sprin klers , 7:' '4 b 0 i .1). j,,,F ._,,..• ...4 ;• sr: ` ,; :ft. ;;;".. Upright Pendent Conventional SmallOrificeUpright I Installation Wrench: Model D Sprin kler Wrench Installation Data Sprinkler Identification Nom i nal K Factor Number (SIN) Sprinkler Type US Metric Sprinkler Height Approvals SSU SSP Standard - Upright (SSU) and Pen dent (SSP) De flee tors Marked to Indicate Position Yz"( 15mm) Stan dardOririce with Y2 " NPT (RYz)Thread 5.6 80 238 "(73mm) 1,2,3,6,7 R3125 R3115 X "(11 mm) Small Orifice with Y2" NPT (RY2) Thread (11 mm) 4.2 60 3X (81mm) 1.2,3,7 R3123 R3113 X " (10mm) Small Or rice with Yz" NPT (RYz) Thread (10mm) 2 8 40 33(6" (81mm) 1,2,3,7 R3121 R3111 10mmOri rice XLH with R Thread 4 2 60 73mm R3124 R3114 1 $2" (20mm) Large Orifice with W NPT(R34) Thread 8.0 115 254" (77mm) 1,2,3,7 R3127 R3117 Conventional-Install in Up rightor Pendent Position 10mm Or ifice XLH with R Thread 4.2 60 73mm R3174 15mm Stan dard Or i fice with Y2" NPT (RYz) Thread 5.6 80 73mm R3175 Model G FRQuick Response Up right & Pen dent In ter me di ate Level Sprin klers 4 -1/! Ob. (11L3hinq /Y Ob. watout A 3 =+fita re Be Aamsndbd -7 r WV OM V' ar eu6auarev Ring Y ,= r =) i -1;,, . cam : 9ddd U (rii_E4j----Ail 0 r Shield a- 7/te' } - 2 -7/b• - (=Sewn) t• Rey - ' I OZObiar) — — h 0 = WOO-6 Upright Pendent InstallationWrench: Model D Sprin kler Wrench Installation Data Sprinkler Identification Nom i nal K Factor Number (SIN) SprinklerType US Metric Sprinkler Height Approvals SSU SSP Standard Up right (SSU) and Pen dent (SSP) De flec tors Marked to In di cafe Po si tion Y2"(15mm) Stan dard Orifice with Y2 "NPT (RY) Thread 5 6 EC 2%" (73mm) 1,2,3,7 R3195 R3115 17 42" (20mm) Large Or i fice with'/." N PT(R>/.) Thread 8 0 115 2' (77mm) 1,2,3,7 R3197 R3117 NOTE -The pro tec uve shield must be as sem bled in the field per the as sem bly drawings. 2. Model GFR Quick Response Horizontal SidewallSprinkler Deflector: HSW1 Installation Wrench: Model D Sprin kler Wrench Installation Data . NominalK ApprovalOrganization Sprinkler , ,a ' Factor and Type of Ap proval (dent. ' ` `N Nominal Sprinkler Light Ordinary Number ' � ' '�� Orifice Thread Size US Metric Height Hazard Hazard (SIN) . Y2" (15mm) Yz " NPT (RY2) 5.6 80 3Ye" (84mm) 1,2,3,7 1.2,3,7 R3135 '/,e" (11mm) Y2" NPT (RY2) 4.2 60 3Ye" (84mm) 1,2,3,7 — R3133 X" (10mm) /" NPT (RY2) 2.8 41 34" (84mm) 1,2,3,7 — R3131 '% " (20mm) Ye N PT (RY2) 8.2 119 338 "(84mm) 1,2,3,7 — R3137 0 Identified by pintle ex tending above deflec tor. Model GFR Quick Response Recessed PendentSprinklers Installation Wrench: Model GFR1 Sprin kler Wrench Installation Data NominalK Factor Sprinkler Identification Sprinkler Type US Metric Height Approvals' Num ber (SIN) '::� " Ye (15mm) Stan dardOnfice 56 80 2 (73mm) 1,2,3,7 R3115 �oa.r+. r ,;=7. 1 with Yf NPT (RY2) Thread 'ie "(11mm)SmallOnficewith 4.2 60 3i(e (81mm) 1,2,3,7 R3113 ` l a Yf NPT (R1i) Thread /.642111,1r____ tip o..rra., "(10mm) Small arificewith 2.8 40 3;read ( (81mm) 1,2,3,7 R3111 Mi0 '' _r ='� 14 •a 8::, Yf NPT (RY2) Thread ,, �- u � 1% ficeXLH ; 4.2 60 (73mm) — R3174 tau Thread t pf 'I (20mm) Large O nfice 8.0 115 2A (75mm) 1;2,3,7 R3117 n with Yr NPT (R'h) Thread i M m Re ferto es cutch eon data table for spe cific es cutch eon a prov als and di men sions. Model GFR Quick Response Recessed Horizontal SidewallSprinklers Deflector: HSW1 Installation Wrench: Model GFR1 Sprin kler Wrench Installation Data Ap proval NominalK Organization° Sprinkler Thread Factor Type of Ap proval Identification Nominal Size Sprinkler Light Ordinary Number r7s i Orifice NPT US Metric Height Hazard . Hazard (SIN) � . mil gu.,r Ye (15mm) Y2"tRY2) 5.6 81.0 3)$e "(84mm) 1,2,3,7 1,2,3,7 R3135 \ rah... 4"(11mm) Y2 "(RYz) 4.2 61.0 3$8" (81mm) 1,2,3,7 — R3133 . a..wab. (1 0mm) Y2"(RY2) 2.8 40.6 3)f6 "(84mm) 1,2,3,7 — R3131 AZ I l a A 17 2 (20mm) 3/4"(R1 8.0 118.2 33te "(84mm) 1,2,3,7 — R3137 I I_{ ill ' I 01 Refer toes cutch eon data table for specifices cutch eon approvals and di men sions. ; J • ASe•Illd al COMM 3. Model GFR & GFR Recessed Quick Re sponse Sprin klers Installation • Finishest1't2' Quick re sponse sprin klers are in tended for stan dard area Standard Finishes coverage and standard water densities as specified in sprinkler Escutcheon NFPA -13. Quick response sprinklers and standard re- sponse sprin klers should not be in ter mixed. Bronze Brass The Model GFR Re cessed Quick Re sponse Sprin kler is to Chrome Plated Chrome Plated be in stalled as shown. The Model Fl or F2 Es cutch eons i� Spe dal Application Finishes lustrated are the only recessed escutcheons to be used Sprinkler Escutcheon with the Model GFR pen dent or Horizontal Side wall Sprin Bright Brass Bri B Plated klers. The use of any other re cessed es cutch eon will void Satin Chrome Satin Chrome all approvals as a quick re sponse sprin kler and ne gate all (11 warranties. Other finishes and col ors are avail able, con suit fac tory for de tails When installing Model GFR Sprinklers, use the Model D All spin klers have black painted sol der links Sprinkler Wrench and when installing Model GFR Re- Temperature Ratings cessed Sprin klers, use the Model GFR1 Sprin kler Wrench. Any other type of wrench may cause sprin kler dam age. Sprinkler Maximum Ambient Classification Rating Temperature Maintenance °F The Models GFR and GFRRecessed Sprin klers should be 165 74 100 38 inspected guar terlyand the sprin klersys tem main tained in Ordinary 212 100 150 66 accordance with NFPA 25. Do not clean the sprinklers with soapandwater, ammonia or any other clean ing flu ids. Re move any dust using a soft brush orgen tie vacuuming. Escutcheon Data Re move any sprinkler which has been painted (other than fac to ap plied) or dam aged in any way. A stock of spare Escutcheon Face of Fitting sprinklers should be maintained to allow quick replace- Model Approvals Adjustment To Ceil ing or ment of dam aged or op er ated sprin klers. Prior to instal la- Wall Dimension lion, sprin klers should be maintained in theorig i nal cartons Fl 1,2,3 y" (19mm) yew -1A" (5mm -24mm) I Fz 1,z,3, and packaging until used. This minimizesthepotentialfor "(13mm) 3fe' ° (5mm -18mm) dam age resulting inimproperoperationornon- operation. Ordering Information: Specify 1. Sprin kler model 2. Sprin kler type 3.Oririce size 4. Temperature rat ing 5. Sprinkler finish 6. Es cutch eon type 7. Escutcheon finish (where applicable) Note: When Recessed Model GFR/F1 or F2 are ordered, sprin kler and es cutch eon are packaged separately. Sprinkler Types Standard Upright Standard Pendent Sidewau — HorizontalHSW1 Deflector Conventional Recessed — Pen dent — Horizontal Side wall HSW1 Deflector Intermediate level — Up right — Pen dent The equipment presented in this bul le tm is to be installed in ac cor dance with the latest pert] nent Stan dardsofthe National Fire Pro tec tion As so a eon, Factory Mutual Researc hCorporatron.ar other sim i lar or ga ni za tions and also with the prow sions of gov em mental codes or or dnanceswhen everap ph ca ble. Prod uctsman ufactured and distributed by Re li able have been protect ing life and propergfor over 80 years. and are installed and serviced by the most highly qual, fled and rep u to blespnnlder con trac tors to cated through out the United States. Canada and for eign coun tries Manu factured by The Reliable to matic Sprin klerCo., Inc. ed (800) 431 -1588 Sales Of faces Sales Paper �eIiab � 800 848-6051 Sales Fax Revisionfinesindicateupdatedornewdata (9 6 68.3470 Cor po rate Of fces www.reliablesprinkler.com Internet Ad dress EG. Printed in U S.A 7(02 P/N9999970024 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY Series 705W FireLock® Butterfly Valve with weatherproof actuator for 300 psi service PRODUCT DESCRIPTION The Series 705W butterfly valve features a weatherproof actuator housing approved for indoor or outdoor use It has a ductile iron body and disc with EPDM disc coating. The body is coated with a heat fused (w polyphenylene sulfide blend to meet FM requirements and the new coating requirements for the 5th r , + edition of UL -1091. For fire protection services, Series 705W valve is UL Listed and FM Approved for 300 psi (2065 kPa) service Flow performance exceeds UL Specification 1091 and FM Approval Standard 1112. ° Weatherproof Actuator -` 4 Supervisory switches that monitor the valve in the fully open position for valves are available 2 - 12" • (73,0 - 323.9 mm) pre -wired (PW) -1 f '',1 2%- 6° Sizes Supply -side Tap Series 705W valves are available with a 1 /4' NPT supply side tap designed to allow direct water supply ` ' connection to Victaulic FireLock actuated fire protection valves See separate drawings below. This is an { optional feature and must be clearly noted on all orders. Contact Victaulic for additional information on tapped valves. 8. 12'Sizes ® 0 See Viclauhc peekaboo 10 01 for details. DIMENSIONS —► K •— i �D? -. li 4 . of � v • . � o M ! I B G . E�� NPT II I ' ` li Supply Tap Ir E WIFE ' • F J ► bI � —►IP - A Series 705W Series 705W with Tap Valve Size Dimensions - Inches/millimeters Nominal Actual Diameter Out Dia E to E Hgt Apra. Incheslmm Inches/rim A B C D E F G H J K L 0 M N P L 2'19 2 875 3 77 9 80 180 3 92 - 2 88 6 97 5 45 7 02 0 97 2 31 4.50 144 060 1.03 9 1 65 73,0 96 249 46 100 - 73 177 138 178 25 59 114 37 15 26 4 1 76,1 mm 3000 3.77 980 1 80 392 - 288 697 545 702 097 231 450 1 50 060 103 91 76 1 96 249 46 100 - 73 177 138 173 25 59 114 38 15 26 4,1 3 3500 377 1048 2 14 4 008 350 761 545 733 097 231 450 175 000' 080 98 80 88,9 96 266 54 107 2 89 193 138 186 25 59 114 45 0 20 4 4 4 4 500 463 11 89 2 71 5 09 0 07 6 01 9 05 5 45 8 59 0 9 2 79 4 50 260 0 73 1 22 15 3 100 114,3 118 302 69 129 2 153 230 138 218 25 71 114 66 19 31 6,9 1397mm 5500 588 1282 312 561 043 601 998 545 859 097 392 450 20D 139 7 149 326 79 143 11 153 253 138 218 25 100 114 - _- 5 5563 588 1282 312 561 043 601 998 545 859 097 392 450 91 - 125 141 3 149 326 79 143 11 153 253 138 218 25 100 114 - - 20 0 6 500 5 88 13 74 3 61 6 06 1 00 7 2 1 9,1 0 165,1 mm 165.1 149 349 92 154 25 183 0 92 5 45 9 05 0 97 3 96 4 50 3 25 1 25 1 50 25 0 138 230 25 101 114 83 32 38 11,3 6 6 625 5 88 13 74 3 61 6 06 100 7 20 10 92 5 45 9 05 0 9 396 4 50 3 32 1 25 1 50 25 0 150 168.3 149 349 92 154 25 183 277 138 230 25 101 114 84 32 38 11,3 8 8 625 5 33 16 92 4 88 794 1 27 10 20 14 06 8 28 13.30 205 266 600 5 10 0 18 0 91 52 0 200 219,1 135 430 124 202 32 259 357 210 334 Table continued on page 2 See notes on page 2 52 152 130 5 23 23.6 e REGISTERED TRADEMARK OF VICTAU\IC - t COPYRIGHT 2004 VICTAUUC - PRINTED IN U 3_1 2466 REV 0 Victaulic Company of America • Phone 1-300- PICK -VIC (1- 800 -742 -5842) • Fax 610 - 250 -8817 • e -mad pichncr6victaulic corn V'ctaullc Company of Canada • Phone 91)5 -834 -7444 • Fax 905 - 884 -9774 • e-mail vir.canadai victaulic com Victaulic Europe • Phone 32 -9 - -1501) • Fax 32 -9- 380 -4438 • e-mail vlceuro$VIflaullc be Vlclauhc.America [alma • Phone 610- 559 -3300 • Fax 610- 559 -3608 • e-mail vital viclau[c.cam i eta L', C® Vlclaullc Asia Pacific • Phone 65 -6235 -3035 • Fax 65- 6235 -0535 • e-mail vlr pV2rnicaul,c com 1 10.18 ti • DIMENSIONS — ► ; K;A- _ ,i�roll v_ o° I e e fi �� l l ; I " 1 $ L i 1 L 4i L E �— H —� A 1.-M -►I p H- A Series 705W Series 705W with Tap Valve Size Dimensions - Inches/millimeters Nominal Actual - - Diameter Out. Dia E to E Hgt. APx indteslmm Incheslmm A B C D E F G H J K L 0„ M N P L 10 4 10 750 6.40 19 14 5.84 8 69 1 72 12 20 15.77 1009 16 19 2 05 3 20 9 00 - - 80.0 250 273.0 163 486 148 221 44 310 400 256 411 52 81 229 - - - 36 12 $ 12 750 6 50 21.54 704 10.00 2 66 14 25 18 28 10.09 17.22 2.05 ' 3 25 9 00 - - - 102.0 300 323,9 165 547 179 254 68 362 464 256 437 52 83 229 - - - 46,3 • On centerline t Contact Victaulic Company of Canada for ULC Listings 1 To prevent rotation of valves, it is recommended that Series 705W be installed with Victaulic Style 07 Zero-Fle0, Style 005 FireLock or Style HP -70 Rigid Couplings If Victaulic flexible couplings are used, additional support may be required 2. Valve must not be installed with disc in full open position Disc must be partly closed so that no part is protruding beyond end of valve body. 3 Victaulic grooved end butterfly valves are permitted for use with grooved end pipe (IPS) only Not permitted for use with plain end (IPS) pipe 4 Series 705W valves are designed for ambient weather conditions as opposed to submersible service MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A -536, coated with polyphenylene sulfide blend, Disc: Ductile iron conforming to ASTM A -536, various grades, EPDM coated. Disc Coating: • Grade "E" EPDM EPDM (Green color code). Temperature range -30 °F to +230 °F ( -34 °C to +110 °C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86 °F ( +30 °C) and hot +180 °F ( +82 °C) potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Stem Bearings: Teflon impregnated fiberglass with stainless steel backing. Stem Bearing Nuts: Type 416 Stainless Steel. Tap Plug: Carbon steel, plated. 0-Ring: EPDM Bracket: Carbon steel, painted. Actuator: • 2 - 6' (65 - 150 mm): Bronze traveling nut on a steel lead screw, in a steel housing. • 8 - 12' (200 - 300 mm): Steel worm and cast iron quadrant gear, in a cast iron housing. 2 Series 705W FireLocko Butterfly Valve 10.18 ' PERFORMANCE The chart expresses the frictional resistance of Victaulic Series 705W in equivalent feet/meters of straight pipe. Valve Size Valve Size Actual Actual Nominal Outside Equiv. Nominal Outside Equiv. Diameter Diameter Feet/m Diameter Diameter Feet/m Inches/mm Incheshnm of Pipe Inches/mm Inches/rum of Pipe 2'/2 2.875 6.500 65 73,0 1,6 165.1 mm 8 165,1 2,5 76.1 mm ;000 5 6 6.625 8 1,6 150 168,3 2,5 3 3.500 5 8'.. 8 625 11 80 88,9 1,6 200 219,1 3.4 4 1 ' 4 500 12 10 10 750 12 114,3 3,7 250 273 3,7 139,7 mm 5.500 12 12 12.750 14 139.7 3,7 300 323,9 4,3 5 5 563 12 125 141,3 3,7 Cv Values Cv values for flow of water at +60 °F ( +16 °C) with a fully open valve are shown in the table below. For additional details contact Victaulic. Formulas for CV Values: A' = 2 Where: Z Cr Q = Flow (GPM) Cv = Flow Coefficient O = C x ,f P AP = Pressure Drop (PSI) Valve Size Valve Size Valve Size Actual Actual Actual Nominal Outside Nominal Outside Nominal Outside Diameter Diameter Cv Diameter Diameter Cv Diameter Diameter C Inches/rum Inches/rum (Full Open) Inches/mm Inches/mm (Full Open) Inches/mm inches/mm (Full Open) 2 2.875 5 500 8 8.625 65 73,0 325 139,7 m m 1150 139,7 200 219,1 76,1 mm 3 000 5 5.563 76.1 325 125 141,3 115 250 10 73 0 5750 3 3 500 6.500 80 88,9 482 165,1 mm 165,1 1850 12 12.750 8300 300 , 323.9 4 4.500 100 114 3 600 150 6 68 3 1850 • Series 705W FireLock® Butterfly Valve 3 . i 10.18 i SWITCH AND WIRING Supervisory Switch 2'/2 - 12" (65 - 300 mm) sizes: Series 705W PW — Two, single pole, double throw, pre -wired switches. Switches are rated 10A @ 125 or 250 VAC 60 Hz and 0.25A @ 250 VDC, 0.50A 4 125 VDC, 2.6A @ 24 VDC Supervisory Switch Wiring A. Pre -wired Switches (1) Switches Supervise Open Valve (2) One switch has two #18 MTW wires per terminal. Permits complete supervision of leads (see diagrams below). Second switch has one #18MTW wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations such as an indicating light and an audible alarm in the area at the valve installation. Switch #1 S1 Switch #2 S2 Normally Closed:(2) Blue S i � Normally Open: (2) Brown Common: (2) Yellow Normally Closed: Blue with Stripe S Normally Open: Brown with Stripe Common: Yellow with Stripe (3) A ground lead, #14MTW is provided (green) UL USTED JUNCTION BOX- - CONCUR ` ,,/ ■ -:-fit` !!! En! "' wiz • ifU CONDuR CONNECTORS ` % f WIRE NUTS n1rw Cann WW1 . �ca°O°a°O9"V KOMINtsm MILT om ivn I SWAM 1120. mro NOTE: Connecting to Common Terminals (Yellow S 1 and Yellow with Orange Slope - S2), and Normally Closed Terminals (Blue St and Blue with Orange Stripe - S2), e g., indicator light and alarm stays on until valve is fully opened, then indicator light and alarm go out. Cap oft unused wire, e.g., Brown and Brown with Orange Stripe Actuator Repair In the unlikely event of an actuator failure, complete actuation replacement is required. ALL REPLACEMENT PARTS MUST BE OBTAINED FROM THE MANUFACTURER TO ASSURE PROPER OPERATION OF THE VALVE. All actuators are supplied with a' /2 NPT outlet for conduit connection. Care must be taken to ensure water does not enter the actuator through this outlet prior to installation. Water entering the actuator will cause switch malfunctions. • This product shall bo manufactured by Victaulic Company All products to be installed In accordance with current V■ctaulic installation /assembly instruclions Viclaulic reserves the nght to change product specifications. designs and standard equipment without notice and without incumng obligations. 4 Series 705W FireLocker Butterfly Valve . IPS CARBON STEEL PIPE — FIRE PROTECTION VALVES 10.08 VICTAULIC'' IS AN 1509001 CERTIFIED COMPANY Series 717 FireLock® Check V a Iv es PRODUCT DESCRIPTION Series 717 FireLock check valve is a CAD - developed design that is hydrodynamically efficient A totally rubber encapsulated disc on 4 - 12° (100 - 300 mm) sizes provides superior corrosion resistance This = ; single disc design incorporates a spring assisted feature for non- slamming operation. For systems requiring a Riser Check option refer to section 10 09 , ' The 4° (100 mm) and larger sizes are provided with upstream and downstream drains and a welded -in nickel seat design All sizes of Series 717 can be installed in the vertical or horizontal position to provide leak -free sealing•under conditions as low as five feet of head Each valve is factory tested to 500 psi see vclau6c (3440 kPa) The 2'12 and 3° (65 and 80 mm) sizes are UL /ULC Listed and 4" (100 mm) sizes and larger are publication 1001 UUULC Listed and FM Approved for services up to 250 psi (1725 kPa). Sizes 4 - 8" /100 - 200 mm (except Sizes 21/2 - 3" for details 165,1 mm size) are VdS approved ,-1A. Grooved ends allow fast, easy installation with just two Victaulic couplings or the valve may be mounted 11r to flanged (ANSI CL 150) equipment using either to Victaulic Style 741 Vic - Flange or Style 744 FireLock tC flange adapters on either end, See Victaulic publication 10.01 for details Sizes 4 - 12" DIMENSIONS A -.I I B - Valve Size Dimensions- Inches/millimeters Actual Approx. gill r 0 - C Nominal Outside Wgt. Ea. Diameter Diameter E to E Lbs. InJmm Inimm A B C D E J K P R kg Typical 21/2 - 3" 2'/ 2 875 3 88 4 26 3.57 - - - - - 3 6 65 73,0 99 108 91 - - - - - - 16 76.1 mm 3000 388 426 357 - - - - 36 76 I 99 108 91 - _ A 3 3 500 4 25 5 06 4 17 - - 1,6 R N- €) 80 89 0 108 129 106 4 5 - - 'l0 01.11 t P irr� 4 4 1 4 500 9 63 6 00 3 88 2.75 3 50 2.00 4 50 3.50 3 35 20.0 t • III4- 100 114,3 245 152 99 70 89 51 114 89 85 91 � � J I N I I D E 5 5 ;63 1 050 6 8 0 d 50 - 4 2 5 88 8 3 173 106 104 27 0 i 12,3 ;:71;:::) � © I 1397 5 500 1050 680 4 50 - 4 17 2.15 5 88 4 08 3.98 27 0 B —.I J If 0 , mm i 139,7 267 173 114 - 106 55 149 704 101 123 O Si* NPT Upstream Drain 6 t 6 625 11 50 8 00 5 00 - 4 50 2 38 6 67 4 73 3 89 38 0 ® W NPT Downstream Drain 150 168.3 292 203 127 114 61 169 120 90 17,2 CI 2• NPT (Drain Option* 6 500 11 8 00 5 165,1 min 4 50 2 38 6 67 4 73 3 89 38 0 165,1 202 203 127 114 61 169 120 99 17 2 Typical 4 - 8" 8 i 8 625 14 00 9 88 6 06 5 05 5 65 2 15 8 85 5 65 5 75 64 0 200 219 1 356 251 154 129 144 55 225 144 146 29,0 A ` 10 10750 1700 1200 709 596 6.69 215 1092 673 1000 00"111111 �^ . _'� 250 273.0 432 '305 180 151 I70 55 277 171 - 45.4 P C 12 127.50 1950 1400 806 691 764 251 1281 773 1400 U � — - — 4.-- _ - - . 300 3 9 495 356 205 176 194 64 925 196 63,5 E 1 Vd5 Approved N-K-.I - B J ® h• NPT Upstream Drain ®W NPT Downstream Drain • Typical 10 - 12" T REGISTERED TRADEMARK OF SICTAULIC - 0 COPYRIGHT 2004 VICTAULIC - PRINTED IN U S A - S W 4WCAS.64VPXF 1479 REV F Victaulic Company of America • Phone 1 -800- PICK -VIC (1-800-742-5842) • Fax. 610 - 250 -8817 • e -mail. pickvic@vlctaulic corn Victaulic Company of Canada • Phone 905 -884 -7444 • Fax 905 -884 -9774 • e -mail. viccanada @vctaullc corn Victaulic Europe • Phone.32- 9- 381 -1500 • Fax 32 -9 -380 -4438 • e -mail: viceuro@vIctaulic be Viclaulic America Latina • Phone 610 -559 -3300 • Fax 610 -559 -3608 • e -mail, vical@victaullc.com JCtaUIic ® Victaulic Asia Pacific • Phone. 86.21- 58855151 • Fax 86 -21- 58851298 • e -mail vlrap@victaulic corn 10.08 FLOW CHARACTERISTICS NOTE. Placement of check valves too close to sources of unstable flow will SERIES 717 shorten the life or the valve and 6.0 I I potentially may damage the system 5.0 FLOWOFWATER To ealend valve life. valves should be 4.0 AT60°F(18°c) .,"" WA.., , ,'��'-,, installed a reasonable dist .�,�""_ expandera r from pumps elbows, THROUGH VALVE 1111111 , ',' ,. I s, reducers Cr other similar 3A F I devices Sound piping practices 6 r , F � �.E,, /AIIK dictate a minimum or live (5) tunes .,""II °„" Ay the pipe diameter for general use 2.0 K Distances between three (31 and rive . 15) diameters are allowable provided N S 14 i Ill__ the flow velocity is less than eight (t;) feet per second 3 4 m Disrin a less than three, O) ) diametnet not ers ale viol recommended dud will violate the a �r�� , i Victmulic product warranty Ob — ����llaurraraII�� 'I■I / cC 0 0.7 / �� ar■■ �� � W 0.8 0 � - -NIIIIIII -A_.l /V 0.5 ���� I ��iI/II�I4�►,�II/ /. /I����I11 u) 0.4 _ _ �11ervign_�,firdli �-AF,IMII11II 0.3 - itiiiiIIIM� 2 1141 cr 0.1 Q. �� I got I�� 10 20 30 40 60 80 100 200 300 400 600 1,000 3,000 4,000 6,000 10,000 20,000 800 3,000 13,000 FLOW RATE - G.P.M. MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A -536. grade 65 -45 -12 Ductile iron conforming to ASTM A -395. grade 65-45-15, is available upon special request. 2'/2 - 3' (65 - 80 mm) sizes PPS coated. 4 - 12' (100 - 300 mm) sizes painted black enamel Body Seat: 2'12- 3° (65 - 80 mm) sizes PPS coated 4 - 12" (100 - 300 mm) integrally welded on nickel alloy Disc Seal or Coating: • Grade "E" EPDM EPDM (Green color code) Temperature range -30 °F to 230°F (-34°C to 110 °C) Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids. oil -free air and many chemical services. UL classified in accordance with ANSI /NSF 61 for cold 86 °F ( 30 °C) and hot 180'F ( 82 °C) potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES, 'Services listed are General Service Recommendations only It should be noted that there are services for which these gaskets are not recommended Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended Discs: 2 - 3" (65 - 80 mm) Aluminum bronze conforming to ASTM B -148 with Grade "E" Seal. 4 - 12° (100 - 300 mm) ductile iron conforming to ASTM A -536. grade 65- 45 -12, fully encapsulated in Grade "E" elastomer Shaft: 2 - 3° (65 - 80 mm) Type 416 stainless steel, 4 - 12" (100 - 300 mm) Type 316 stainless steel Spring: All sizes Type 302/304 stainless steel Shaft Plug: 2 - 3° (65 - 80 mm) only, SAE Hex Socket Type conforming to ASTM A -576, cadmium plated to military specifications - P -416A, class 3 type 2. 4 - 12° (100 - 300 mm) only, carbon steel zinc plated to ASTM B -633. Pipe Plug: 4 - 12' (100 - 300 mm) only, carbon steel zinc plated to ASTM B -633 This product shall be manufactured by Victaulic ?rmpany All products snail be nutailed in accordance with :urgent VPaaulc in instructions Viciauiic resolves the right to change product specifications designs and standard equipment without notice and without mcun;ng obhgepons 2 Series 717 FireLockm Check Valves • IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.17 VICTAULIC• IS AN ISO 9001 CERTIFIED COMPANY Series 7 28 FireLock® B a II V a Iv e PRODUCT DESCRIPTION The Series 728 FireLock° valve is a standard port, end -entry valve V i ' that is UUFM rated for 350 psi (2410 kPa) service in all sizes. (..• j - Available with grooved or threaded ends (NPT), the valve body and „ #,_ gearbox are brass die cast. The ball Is chrome plated brass with a - ` brass stem. TFE seats aid ease of operation and provide a - corrosion -free seat The streamlined design provides excellent flow a characteristics, which exceed UL Specification 1091 and FM 'j : rt Approval Standard 1112. See Viaaudc fir' '0‘' ,4 ,. ` ' ', publication 10 01 for details DIMENSIONS K� J . i• K--01 J f -H--ii I I H l7 :� 1'1 v I .1i 4 !�' � g �, ♦"= A o ; et� ' = l 0 I sk G r : I - ~- L - 1 / 1. Co A F F Grooved X Grooved Threaded X Threaded SIZE Dimensions - Incheshnlllimeters Alm Nominal E to E Height W Lbs. Inches A 8 C 0 F G H J K L 0 kg 1 Thd X Thd. 2 84 5 61 0.93 1.22 1.87 2 27 3 39 5 62 1 86 1.42 2 75 5.1 72 143 24 31 48 58 86 143 47 36 67 2.3 1 4 Thd XThd 331 6.04 115 153 230 247 339 562 1.86 165 275 58 84 153 29 39 58 63 86 143 47 42 67 2.6 1' /2 Thd X Thd 3 6.42 1.35 1 71 2.66 2 66 3.39 5.62 1.86 1.83 2 75 6 6 92 163 34 43 68 68 86 143 47 4 7 67 3.0 2 Md. X Thd. 4 33 7 15 1 71 2.07 3 40 3 05 3 39 5 62 1.86 2 16 2 75 8 5 110 182 43 53 86 77 86 143 47 55 67 3.9 1 Grv. X Gry 7 25 6 25 1.15 1.67 2 30 2.58 3 39 5.62 1 86 3 19 2.75 7.5 184 159 29 42 58 66 86 143 47 81 67 3.4 1'l2 Gry XGry 725 6.75 135 189 271 280 339 5.62 186 3.19 275 8.5 184 171 34 48 69 71 86 143 47 81 67 3,9 2Grv.XGry 725 750 171 225 316 350 3.39 562 1.86 319 275 105 184 191 43 57 80 89 86 143 47 81 67 4.8 PERFORMANCE SIZE Equivalent' SIZE Equivalent' Nominal Inches Feet/meters of Pipe Nominal Inches Feet/meters of Pipe 1 Thread X Thread U 2 1 Groove X Groov 1.4 0,4 1 Thread X Thread o 1 Groove X Groove p 0 1 Thread X Thread 1 7 2 Groove X Groove 1 2 0.5 0.4 2 Thread X Thread 0 5 0,2 'Calculated using Hazen - Williams with C 120 e REWIRED TRADEMARK OF YICTAUUC - 0 COPYRIGHT 2013 VICTAUUC - PRINTED in USA 2226 REV B Victaulic Company of America • Phone 1 -800- PICK -VIC (1- 800 - 742 -58a21 • Fax 610 -250 -8817 • e-mail pickvIci vlctaulic com Viciaulicc Company of Canada • Phone 905- 884 -7444 • faa 905- 384 -9774 • e-mail vlccanada(5victaullc corn Victaulic Europe • Phone 32-9-331-1500 • Fax 32 -9- 380 -a438 • e -mail vlceurolMrtaulic be Victaulic America Latina • Phone 610 - 559 -3300 • Fax 610 - 559 -3503 • e -mail `AC2i 9'viclaulic corn jctaullic° Victaulic Asia Pacific • Phone 65- 6235 -3035 • Fax 65- 6235 -0535 • e -mail vlcap eIctauliccom , 1 10.17 SWITCH AND WIRING Supervisory Switch The supervisory switch contains two, single pole, double throw, pre -wired switches. Switches are rated: 10 amps @ 125 or 250 VAC /60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC Supervisory Switch Wiring A. Pre -wired Switches (1) Switches supervise valve in "open" position (2) One switch has two #18 MTW wires per terminal, which permit complete supervision of leads (refer to diagrams and note below). The second switch has one #18MTW wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. (3) A #14MTW ground lead(green) is provided Switch #1 51 Switch #2 S2 i Normally Closed.(2) Blue S1 Normally Open: (2) Brown Common: (2) Yellow Normally Closed: Blue with Orange Stripe 32 Normally Open: Brown with Orange Stripe Common. Yellow with Orange Stripe UL LISTED JUNCTION BOX FIRE ALARM • END O pp RES 4T0R CONTROL PANEL OR NEXT OiDICATOR SUPERVISORY CONDUIT x '40 uRDUR ►� SWITCH eoNrACT RATING 11 7 =III [44tll _ v Iii_- 10A AT 12 AND _ OSA 727 VDC. NPT� 027 AT 270 VDC m CONDUR CONNECTORS � / =t�M BELL VOLTAGE SOURCE HORN S.W. I:2 INNIs pr MmOntl WIRE NUTS Brach t 1 Mad per Nankai NOTE: The above diagram shows a connection between the common terminal (yellow -S1) and yellow - with- orange stripe -S2) and the normally closed terminal (blue -S1 and blue- with- orange stripe -S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown and brown with orange stripe). MATERIAL SPECIFICATIONS Valve Body: Bronze ASTM B -854 Alloy 844 Ball: Chrome Plated Brass Stem: 316 Stainless Steel Seat: (TFE) tetrafluoroethylene • Stem Nut: Brass ASTM B -16 C36000 Quadrant Gear: 316 Stainless Steel Main Stem: Brass ASTM B16 C36000 • Worm Gear: AISI 1144 Steel This product shall be manufactured by Victaulic Company All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incumng obligations 2 Series 728 FireLock Ball Valve ES -B6000 For Commercial and Industrial Applications ., Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative Series B6000, B6001 -= 86001 2- Piece, Standard Port, ,� , , ��� Bronze Ball Valves � , 1 11 11 '. . .-" f' I 7 Al . 1 Sizes: /a - 4 (8-100mm) "' { � ,,.� . ' Series B6000, B6001 2- Piece, Standard Port, Bronze Ball Valves Options feature a blowout proof pressure retaining stem. The B6000, B6001's p standard port orifice ensures minimal pressure drop, while Durafill® Suffix and Uniseal® seats and chrome plated brass ball provide lasting 01NT- Virgin Teflon® seat material service for a wide range of liquids and gases. SS- 316 stainless steel ball and stem LH- Locking lever handle Features OV- High profile safety oval handle OVLH- Oval locking handle • Durafill® (carbon/glass filled PTFE) seats for sizes W —'/z' RH Round Handle (8 — 15mm) and 1W — 4' (32 — 100mm) and Uniseal® (enhanced B Stainless steel handle and nut PTFE) seats for sizes 14' & 1' (20 & 25mm) for lasting service for BSS - Ex stop XH- Extended np ended handle a wide range of liquids and gases TH Tee handles' Y: - 2' (8 - 50mm) • Chrome plated brass ball is wiped clean during each operation of GS- Ground Washer the valve CC - 44' (20mm) hose thread outlet. Hose thread outlet has cap 8 chain. Inlet sizes: IN and W (15 - 20mm) NPT. Also 1/2' and 4': (15 -20mm) • Minimal pressure drop due to large ports solder inlet connection • Blowout proof, pressure retaining stem CL- Chain lever kit W -1' (20 -25mm) • 'Ya' — 3' (8 — 80mm) pressure rated at 600psi (41 bars) WOG 5- Rough chrome 2' (8 1 non - shock; 150psi (10 bars) WSP. 4' (100mm) pressure rated at Z 04- Mineral Mi and nut l filled PTFE seats and seals (available only with 316SS ball 400psi (28 bars) WOG non - shock; 125psi (8.6 bars) WSP (over and stem) 150psi steam requires SS trim) U.L.- UL approved as follows: • High cycle life reinforced PTFE stem packing seal and thrust washer Flammable Liquids (YRBX) LP Gas (YSDT) - Compressed Gas (YQNZ) - NaturavManufactured Gas (YRPV) • Vinyl insulator on heavy duty, zinc - plated, carbon steel handles - Fire Protection (HNFX) - For #1/12 Fuel'Oils (MHKZ) • Quarter -turn open or close operation • Low operating torque Pressure - Temperature • Adjustable stem packing gland • Each valve factory tested Temperature Range: 0 ° F — 450 °F ( -18 °C — 232 °C) ® 50psi (3.4 bars) Pressure Range: Models 'A' — 3' (8 — 80mm), 600psi (41 bars) WOG non - shock; 150psi (10 bars) WSP B6000 W — 4' (8 — 100mm) threaded NPT end connections 4' (100mm), B6001 3/4' — 3' (10 — 80mm) solder end connections* 400psi (28 bars) WOG non-shock; 125psi (8.6 bars) WSP Use stainless steel trim (option SS) for steam pressures over 150psi Specifications (10 bars). A 2 -piece standard port bronze ball valve to be installed as indicated This valve is designed to be soft soldered into lines without disassembly, on the plans. The valve must have a blowout proof pressure retain- using a low temperature solder 420 °F (216 °C). Other solders such as 95/5 ing stem, Durafill® seats (I — & VA' — 4') or Uniseal® seats (3Ya' tin antimony 460 °F (238 °C) or 96/4 tin sliver 420 °F (216 °C) can be used, 8 1"), reinforced PTFE stem packing seal, and chrome plated brass however extreme caution must be used to prevent seat damage. Higher tem- loaded stems or valves without ad pack- pasture solpers will damage the seat sold ANSI t B.16.18 is 200 states that the ball. Valves with top I P maximum operating pressure of 50 -50 solder connections is 200 psi (14 ing are not acceptable. Pressure rating no less than 600psi (41 bars) bars) at 100 °F (38 °C) and decreases with higher temperatures. - WOG non - shock; 150psi (10 bars) WSP for 'A° — 3' and 400psi (28 Apply heat with the flame directed AWAY from the center of the valve body. bars) WOG non - shock; 125psi (8.6 bars) WSP for 4 ". Valve must Excessive heat can harm the seats. Atter soldering, the packing nut may have conform to MSS -SP -110 and shall be a Watts Regulator Company to be tightened. Series B6000 (threaded) or B6001 (solder). WA ® Durafill® is a registered trademark of Cargill, Limited. Uniseal® is a registered trademark of Uniseal, Incorporated. WREGULATOR Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or matenals with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Materials Valve Seat Rating ' � � A ban pal . 9 41 V: - T(9 -Bomm) SIZE CV OPERATING 34 900 (ON) RATING TORQUE In. mm mA's. Nm ® D e 28 400 r (100mm) 'A 8 6 60 6.8 , m 21 300 1/2 15 15 60 6.8 G ) H 14 200 � �4 20 25 90 10.2 E - -® ® � l ` 9 -- 1 25 40 150 16.9 (% N r 100 III . 1% 32 50 175 19.8 F 'I�) J 350 1'k 40 75 200 22.6 VV 100 200 300 400 500 •F 2 50 110 250 28.2 A Handle Nut Zinc Plated Carbon Steel 93 149 204 260'0 2'k 65 260 500 56.5 B Handle Zinc Plated Carbon Steel with Vinyl Temperature 3 80 400 600 67.8 Insulator 4 100 450 800 90.4 C Packing Nut Brass ASTM 816, C36000 Pressure Drop vs. Flow 0 'Stem Packing Glass Reinforced PTFE wav8 E Thrust Washer Glass Reinforced PTFE 18 20 r F Stem Brass ASTM B16, C36000 ea ,o 11111111 _ , II ae 11 G Body Cast Bronze ASTM B584, C84400 85 41 6 a _ ,a_ , _ ,- i ll ���..u•. . l 4.-...::::;„:„.2.,,:-_= . ti • i H Seats Durafille ( - W & 1' /i - 4') ��� ■ ■���� ■ r ��r , _ a z 3 :■■1111VASTiVari I Ball Chrome Plated Brass ASTM 816, C36000 0 14 2 1 / 111111 . 1 IIIMAPH1VRAIFINIII. J Adapter Brass ASTM B16, C36000 I 71.a ■„"'NIV EN'VA 'Mill!. K Body Seals PTFE (1W -4' only) - Not shown H 6 .5 5 - - -:: :Z= _,.. : • - -- aI: a. Dimensions - �� • AMIAI U III 1w , a .mn� Weights 9 H 21 .4 �I�� ri■nlr���oi■�esaetii�i�ta■uuri ■ 2 ., t l• t1I,/1 11►, It/II /A► /1►,IIIt/ /MIII11111t1• �1•/III PIIII h,I /IIIIVa'/IIIIIIII� "'� 1.4 . W►11►1I J �ur� - a- - ai Hgi 118 il ��.r - I I- MMIII= J .. N 'at m m ° Flow a s ° o a - -- E • ---I • 86000 I. SIZE DN DIMENSIONS WEIGHTS C E H I J L • Center to Radius of Dia. Solder Depth Solder Handle Center to End Handle Ball Onfice Connection End to End Connection in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kg. '/4 8 1 45 1'%e 27 3' /ie 78 M 10 - - 2'/ie 52 - - 0.6 0.3 ? 10 1 45 1' /,e 27 3'/%6 78 1 10 - - 2' /%e 52 - - 0.6 0 3 1/2 15 1 45 1%6 27 3 95 1/2 13 - - 2'% 58 - - 0.6 0.3 % 20 2 51 1 /ie 36 3 95 'V18 17 - - 2t 72 - - 1.0 0.5 1 25 2'% 57 1"/18 43 41/2 114 r 22 - - 33/4e 87 1.6 0.7 1 32 2 64 1% 49 3% 97 1 25 - - 3% 99 2.2 1.0 11/2 40 3 76 21 54 51/2 140 1'% 32 - - 4'% 108 - - 3.2 1.5 2 50 31/48 84 2' /%e 62 51/2 140 1 38 - - 4 122 - - 4.9 2.2 21/2 65 4 102 31/46 81 81 206 2 51 - - 61/2 165 - - 13.2 5.9 3 80 4'% 108 3%16 87 81/2 206 21/2 64 - - 6' %e 173 - - 17.5 7 9 4 100 4' 122 31 98 11 279 3 76 - - 7 "Ae 195 - - 29.3 13.3 86001 1/2 10 11/2 38 1' /i6 27 3 95 1 10 1/2 13 231e 58 3a 9 0.5 0.2 1/2 15 1 44 We 27 3 %4 95 1/2 13 3 16 2% 60 1/2 13 0.6 0.3 . % 20 2 51 1'/ie 36 3%4 95 11 /18 17 % 22 31/46 84 3'4 19 1.1 0.5 1 25 2'%4 57 1%4 44 41/2 114 % 22 11 28 3%4 95 % 22 1.4 0.6 1'% 32 21/2 64 2'% 57 3 97 1 25 11/4 35 41/2 114 1 25 2.0 0.9 11/2 40 3 76 21/2 64 51/2 140 1% 32 11 41 5 127 11/4e 27 3.3 1.5 - 2 50 3146 84 31/2 80 51/2 140 11/2 38 21/2 54 6'% 159 13/18 34 5.2 2.4 21/2 65 4 102 3 "/e 93 81 206 2 51 2 67 7% 194 1'/18 36 13.2 6.0 3 80 4'% 108 4' /%e 103 81/2 206 21/2 64 31/2 80 836 208 1 "ha 43 15 6 7.1 ' See Solder Instructions on front. % WATrS® ' x'' 9001 CERTIFIED USA: 815 Chestnut St., No. Andover, MA 01845 -6098; www.wattsreg.com REGULATOR Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca ES-B6000 0419 © Watts Regulator Co., 1997 Printed in U.S.A. • P POT-fER • VSR-F V ANE TYPE WATERFLOW ® The Symbol of Protection ALARM SWITCH WITH RETARD UL, ULCandCSFM Listed, FMandLPCBApproved, NYMEA Accepted, CE Marked Service Pressure: Up to 450 PSI (31 BAR) Minimum FlowRateforAlarm:10 GPM (38 LPM) . • Maximum Surge: 18 FPS (5,5 m /s) \, Contact Ratings: Two sets of SPDT (Form C) 15.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive � Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: r • Suitable for indoor or outdoor use with factory installed ��! ''� 7.: � gasket and die -cast housing. t= ' • NEMA 4/IP54 Rated Enclosure - use with appropriate " F / \ conduit fitting. * • Temperature Range: 40 ° F /120 °F, 4,5 °C /49 °C .? :_ • Non - corrosive sleeve factory installed in saddle. ;E; Caution: This device is not intended for applications in explosive 1 r. environments. - Sizes Available: Steel Pipe schedules 10 thru 40, sizes 2" thru 8" \� At BS 1387 pipe 50mm thru 200mm Note For copper or plastic pipe use Model VSR -CF. " nom Service Use: U.S. Pat. No. 3921989 Automatic Sprinkler NFPA -13 Canadian Pat. No. 1009680 One or two family dwelling NFPA -13D Other Patents Pending Residential occupancy up to four stories NFPA -13R Potter Electric, Rd., 1990 National Fire Alarm Code NFPA -72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 GENERAL INFORMATION INSTALLATION: See Fig.2 The Model VSR -F is a vane type waterflow switch for use on These devices may be mounted on horizontal or vertical pipe. wet sprinkler systems. It is UL Listed and FM Approved for On horizontal pipe they should be installed on the top side of the use on steel pipe; schedules 10 through 40, sizes 2" thru 8" pipe where they will be accessible. The units should not be in- (50mm thru 200mm). stalled within 6" (15cm) of a fitting which changes the direction of LPC approved sizes are 2" thru 8" (50mm thru 200mm). the waterflow or within 24" (60 cm) of a valve or drain. The unit may also be used as a sectional waterflow detector Drain the system and drill a hole in the pipe using a circular saw on large systems. in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices The unit contains two single pole, double throw, snap action require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm adjustable, instantly recycling (50 ±2mm). All other sizes require a hole with a diameter of 2" t1 /8" switches and an ad 1 y cy g pneumatic re- (50 ± tard. The switches are actuated when a flow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. Clean the inside pipe of all growth or other material for a dis- The flow condition must exist for a period of time necessary to tance equal to the pipe diameter on either side of the hole. overcome the selected retard period. Roll the vane so that it may be inserted into the hole; do not bend ENCLOSURE: The unit is enclosed in a general purpose, die- or crease it. Insert the vane so that the arrow on the saddle • cast housing. The cover is held in place with two tamper resis- points in the direction of the waterflow. Install the saddle strap tant screws which require a special key for removal. A field in- and tighten nuts alternately to an eventual 50 ft-lbs. (68 n -m) of stallable cover tamper switch is available as an option which torque (see Fig. 2). The vane must not rub the inside of the pipe - may be used to indicate unauthorized removal of the cover. See or bind in any way. bulletin no. 5400775 for installation instructions of this switch. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146 -4161 • Phone: 800 - 325 -3936 /Canada 888 -882 -1833 • www.pottersignal.com PRINTED IN USA MKT. #8800001 - REV W PAGE 1 OF 2 MFG. #5400761 - 7/02 P O TTER VSR -F ® The Symbol of Protection VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FIG.1 FIG. 2 SWITCH TERMINAL CONNECTIONS OPTIONAL TAMPER SWITCH DO CLAMPING PLATE EXTENDED LEAVE COVER TIME TERMINAL RETARD ADJUSTMENT: ` TO CHANGE TIME TURN KNOB (EITHER DIRECTION) ill FOR DESIRED TIME DELAY. USE THE MINIMUM io it �� ' TIGHTEN NUTS ', AMOUNT OF RETARD NECESSARY TO PREVENT =' \:, \ � ALTERNATELY 7. FALSE ALARMS. A -' SETTING IS USUALLY Nio, � ' � I EVENTUAL 80Fi, ( ) �� ADEQUATE FOR THIS, FACTORY IS SET TO 'g', T O �I OF TORQUE LB 89 n -m INSTALL DRILL HOLE AS INDICATED (' NaOk\ ore 1023 ® HOLE SIZE a - 2' to 2 t /2' t t /4' +1 /e' -t /te CAUTION: (om'"'^ to 65mm) (33mm t2mm) Y� O AN %,.1111 ARROW MOUN ON SADOLE An uninsulated section of a 3- a to m to 200mm 2° �' /e° POINTS IN DIRECTION 50mm t2mm) 1111 OF WATERFLOW single conductor should not be looped around the termi- Cover Tamper , ROLL PADDLE IN OPPOSITE DIRECTION nal and serve as two sepa- (with cover in place) OF WATERFLOW rate connections. The wire must be severed, thereby DIRECTION OF providing supervision of the WATERFLOW connection in the event that OnIT) rm I Box) APPROX. RETARD SETTINGS (IN SECS.) m�• the wire becomes dislodged \ \ \ \VV / / /�� from under the terminal. °WC• /7s, -so B 10 A 30 ME FIG. 3 TYPICAL ELECTRICAL CONNECTIONS NOTES: FIG. 4 1. The Model VSR - has two To remove knockouts: Place o. switches, one can be used to screwdriver at edge of knock Cu& Cs ,, operate a central station, pro- outs, not in the center. `_ Cm rat Pon WE , prletary or remote signaling ° ' o �;1 1 unit, while the other contact is G i :c l I I : . i I used to operate a local audible 0 0 0 T r 0 or visual annunciator1 2. A condition of LPC Approval of co __I i °` a a a a r ` K this product is that the electri- n< � . oe Q cal entry must be sealed to m sum zoom" .a �` wax ° `�` exclude moisture. _! oe D OD�Of4, a41w+9 0 3. For supervised circuits see � a ,� 0 ' ° Switch Terminal Connec- a �f �� lions° drawing and caution note (Fig. 1). °N ` X 761 ` APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or 9 chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR -F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR -F is not recommended or advisable. A minimum flow of 10 gpm (38 Lpm) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT. #8800001 - REV W MFG #5400761 - 7/02 PAGE 2 OF 2 .. P POTTER BELLS PBA -AC 8 PBD-DC ® The Symbol of Protection UL Listed, FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized Vomit .�. 24VDC (20.4 to 31.2)' ?olarized Service Use: Fire Alarm ... General Signaling 0 - ) BurglarAlarm Environment: Indoor or outdoor use (See Note 1) -40° to 150 °F (-40° to 66 °C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK -1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK -1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK -1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT -IN TRANSIENT PROTECTION: am INCHES VOLTAGE MODEL NO. STOCK NO. CURRENT TYPICAL dB M dB (mm) (MAX.) AT 10 FT. AT 10 FT. ( (2) Dm) (1) 1) 6 (150) 12VDC PB0128 1706012 .12A 85 78 8 (200) 12VDC P80128 1708012 .12A 90 78 10(250) 12VDC PB01210 1710012 .12A 92 78 8(150) 24VDC P80246 1706024 .06A 87 76 8 (200) 24VDC PBD248 1708024 06A 91 79 10 (250) 24VDC PBD2410 1710024 .06A 94 79 8(150) 24VAC PBA246 1806024 .17A 91 76 8(200) 24VAC P8A248 1808024 .17A 94 76 10(250) 24VAC PBA2410 1810024 .17A 94 78 6(150) 120VAC PBAl208 1808120 .05A 92 82 8(200) 120VAC P8Al208 1808120 05A 99 82 10 (250) 120VAC PBAl2010 1810120 05A 99 B5 Notes: - 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150 °F ( -34° to 66 °C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146 -4161 • Phone: 8 00 -325- 3936 /Canada 888 - 882 -1833 • www.pottersignal.com PRINTED IN USA MKT #8850001 - REV O PAGE 1 OF 2 MFG #5400776 - 12/01 P PyTTE BELLS PBA -AC & PBD -DC ® The Symbol of Protection DIMENSIONS INCHES (mm) FIG. 1 BELLS FIG. WEATHERPROOFBACKBOX BOX HAS ONE THREADED 1/2" CONDUIT ENTRANCE rE_ �� o et 10' 1 .. - -_j (250) B' - 1 a— S 3/4" 0 _ 3 3/8' s (200) 8' I i (146) (127) ( � �� I I _` ter_ I J- i vi —1841 15/81661- 3 3/8' (41) (86) 2 11/16'. -- 4 1/4' (68) ONG. #n6 -1 (108) ONG. #776 -2' FIG. 3 WIRING (REAR VIEW) • D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RE° (M) ■/11111. RED (OUT) mmZ (DR) MOTE (OUT) ■ IRON CONTROL MEL ro / TO NEXT (OIL PROW CONTROL PNNEL irl , P7fE, O RRC eEtl OR END- o. -„NE ' RED RECE BELL ' (IN) _� BUM (OUT) B Udt ON) _ � BUCX (Our) I MI GAUDIkt CALM= MIEN =TRIM. SUPERVISION IS REOUIREO USE IN AND OUT LEADS AS SHORN MEN ELECTRICAL SUPERVISOR IN REWIRED USE M AND OUT LEADS AS SNONN. NOTES: NOTEST 1. OBSERVE POLARITY TO RING D.C. BELLS. I. WHEN USING A.C. BEDS, TERMINATE EACH EXTRA WIRE SEPARATELY 2. RED WIRES POSRIVE ( +) AFTER LAST BELL 3. BLACK WIRES NEGATNE (-) 2. END -OF -NNE RESISTOR IS NOT REQUIRED ON A.C. 8EU.S. DWG. #776 -3 INSTALLATION 1. The bell should be mounted a minimum of 8 ft. (2,4m) from the floor or as close to the ceiling as possible. - 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REV Q PAGE 2 OF 2 MFG. #5400776 -12/01 20 AUG 3 07 CITYpF T/p BUILDING DI DELTA,. FIRE FIRE,INC. FIRE PROTECTION CONTRACTORS 14193 SA 12rd PORM419, OR 91714 (503) 520 -4071 DELTA FIRE, INC. 14795 SW 72nd Ave. Portland, OR 97224 503 620 -4020 • Job Name : FANNO CREEK BUILDING "A" L3 Building : "A" Location : UPPER BOONES FERRY RD. AND SW 72ND (FANO CREEK) System : 01 Contract : 06 -3534 Data File : FANNAL3 -.wx2 • Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 DELTA FIRE, INC. Page 1 FANNO CREEK BUILDING "A" L3 Date 070207 Hydraulic Design Information Sheet Name - FANO CREEK PLACE BUILDING "A" Date - Location - UPPER BOONES FERRY RD. AND SW 72ND (FANO CREEK) Building - "A" System No. - 01 Contractor - OPUS NW Contract No. - 06 -3534 Calculated By - MICHAEL STEWART Drawing No. - Construction: ( ) Combustible (X) Non - Combustible Ceiling Height - 9' -0" Occupancy - LIGHT HAZARD S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp., ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1020 System Type Sprinkler /Nozzle Density - .10 (X) Wet Make RELIABLE D Area Per Sprinkler - 225 ( ) Dry Model Fl /FR E Elevation at Highest Outlet - 34.833 ( ) Deluge Size 1/2" S Hose Allowance - Inside - 100 ( ) Preaction K- Factor 5.62 I Rack Sprinkler Allowance - 0 ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 0 N Note REMOTE AREA OPERATION 32% REDUCTION FOR QR - NFPA2002 11:2.3.2.3.1 Calculation Flow Required - 285.54 Press Required - 59.3 Summary C- Factor Used: 120 Overhead 140 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 08/02/2006 Cap. - T Time of Test - NA Rated Cap.- Elev.- E Static Press - 106 @ Press - R Residual Press - 102 Elev. - Well. Flow - 1807 Proof Flow S Elevation - 0 P Location - SW 72ND AVE AND UPPER BOONES FERRY RC P L Source of Information - CITY OF TIGARD Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) Page 2 D DELTA FIRE, INC. FANNO CREEK BUILDING "A" L3 Date 070207 Demand: 14.942 City Water Supply: D1 Elevation Cl - Static Pressure : 106 D2 - System Flow :185.5 2 C2 - Residual Pressure: 102 D2 - System Pressure : 59.319 C2 - Residual Flow :1807 Hose (Adj City) . 100 Hose ( Demand ) D3 - System Demand : 285.538 Safety Margin 150 140 130 P 120 C2 R 110 C1 E 100 S 90 S 80 U 70 D• R 60 E 50 I3 40 30 : 20 10 D1 - . . . , - - - ' - . ' - - - - - 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N A 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 • Fittings Used Summary Page 3 Date 070207 DELTA CREEK FANNO CREEK BUILDING "A" L3 g 10 12 14 16 18 20 24 Legend % e 1% 1% 2 2% 3 3% 4 5 6 Fitting Leg �� 1 p p Abbrev. Name 10 12 19 1''I 0 0 0 61 7 10 p 12 9 45 50 0 0 0 0 6 7 6 10 12 14 18 22 60 71 61 91 101 121 B Generic Butterfly Valve 2 2 2 3 4 5 1 7 20 25 30 35 50 40 45 50 61 E 90' Flow o Thr Elbow 4 5 10 12 15 10 25 3 0 3 5 50 22 27 71 T 90' FI w See 3 3 4 5 6 7 8 Z Generic Flow Switch 2 2 2 Units Summary Diameter Units Inches Feet Length Units US Gallons per Minute Pressure Units Pounds per Square Inch • Pressure Units Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 r Pressure / Flow Summary - STANDARD P 4 rt Date 070207 ' DELTA CREEK BUILDING "A" L3, Pn Flow Density R,, Pt actual Node Elevation K•Fact Actual No. 225 7.0 22.5 0.1 16.03 na 22.55 4201 32.5 K62K @ EQ01 16.99 n a 22.89 42 34.58 K = K @ EQ01 17.49 na 22.8 41 34.58 K = K @ EQ01 18.9 na 22. 38 34.5 Kn. K @ EQ01 17.4 na 37 32.5 24.26 na 18 32 24.46 32.5 24.43 na , 12 32.5 24.43 na 32 32.5 23.75 na 21 32.5 23.45 na 28 32.5 23.7 07 na 5 32.5 22.65 na 23.71 • 6 32.5 K = K @ EQ 01 18.78 n a 23.72 40 34.58 K = K @ EQ01 18.79 na 52 34.58 20.29 na 25 32.5 23.91 na 32.5 24.09 25 32.5 25.7 na 24 32.5 25.79 na 23 32.5 24.33 na 33 32.5 22.91 na 35 32.5 2 na 23.67 51 32.5 EQ01 18.71 na K= K© na 23.66 36 34.5 K = K @ EQ01 18.7 na 34.5 23.7 35 19 32.5 24.47 na 32.5 25.7 na 19 32.5 25.72 na 21 32.5 25.7 na 100.0 22 21 32.5 53.47 na 0.0 23.09 na HOSE 32.5 23.65 na 8 32.5 24.18 na 9 32.5 24.18 73 na 10 32.5 25.87 na 11 32.5 45.72 na BOR 1.66 45.72 na 32.16 37.77 na TOR 32.5 39.41 na 13 32.5 39.4 na 14 0.0 54.2 na TEST 0.0 TEST The maximum velocity is 14.12 and it occurs in the pipe between nodes 52 and 8 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen - Williams - DELTA FIRE, INC. Page 5 FANNO CREEK BUILDING "A" L3 Date 070207 Pt Pt Oa Dia. Fitt g Pipe Pt Pe Pn ""'�" Notes Hyd. C Pf Ref. Qt PfIFt E qv . Ln. Total Point S101 22.50 1.049 IT 5.0 0.410 16.029 K Factor = 5.62 0.0 5.000 0 . 0 Vel = 8.35 to 0.1 120 0.0 5.410 0.875 EQ01 22.5 0.1617 • 0.0 16.904 K Factor = 5.47 22.50 16.986 K Factor @ node EQ01 42 22.55 1 0 0.0 11.750 20 0,0 0.0 0.0 .0 Vel = 4.84 to 0. 0 11.750 0.503 41 22.55 0 0428 17 488 K @ node EQ01 1T 6.0 6.160 41 22.89 1 0.0 6.000 0.901 Vel = 9.75 -_ to 120 0. 0 12.160 1.899 52 45.44 0.1562 _- K Factor = 10.09 0.0 20.289 45.44 16.904 K Factor @ node EQ01 0.0 11.750 38 22.50 1 0.0 0.0 0 . 0 Vel = 4.83 to 0.0426 0. 0 11.750 0.500 node EQ01 37 22,5 0.0426 17.404 K Factor @ 1T 6.0 6.160 O,g66 37 22.83 1 0.0 6.000 Vel to 120 0.0 12_160 1.891 51 4 ...... - 0.0 __ 20.181 _ Facto Kr = 10.10 - . _ 45.33 _ 2.830 24.258 _ _ - - - 9.24 1.442 1T 7.432 7.432 0.0 17 120 0.0 0. 068 -- .. - Vel = 1.:82 - -- to 0.0 10.262 _ � 9.24 0.0066 0.0 24.326 K Factor = 1.87 9.24 2p 24.457 6 1.442 1T 7.432 7.432 0.0 18 0.0 Vel = 1.25 _ __ to 120 0.0 9. _ .0.033 - -- 33 6.36 0.0034 - _ _ , - _- KFactor = 1.29 . _ 0.0 24.490 6.36 - -_ -.- . 24.429 32 9.08 1.442 2E 7.432 149.250 0.0 120 6T 44.592 52.024 0.0 Vel = 1.78 to 0. 201.274 21 9.08 0.006 0.0 9.0 25.719 K Factor = 1.79 _ 8 9.47 1.442 4E 14.864 156.160 24.360 �- 8,47 0 0..0 069 24.0.33 31 4? 29.728 44.592 1.392 Vel = 1.86 to 0. 0 200.752 0 _ 0.0 25.752 K Factor = 1.87 9.47 2.080 23.754 -21.01 1.442 1T 7.432 0 7.432 0.0 to 120 Vel = 4.13 to 0.0 9.512 -0.288 5 _ -21.01 -1.442 1T 7.432 5.660 23.466 5 0.0 1.442 g -21.01 .0 -0.0 302 0.0 7.432 0.0 Vel = 4.13 to 0 0. 0 13.092 -0.396 Computer Programs by Hydrates Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard Page 6 • CREEK . DELTA INC. FANNO CREEEK BUILDING "A" Date 070207 L3 Pt Pt Hyd. Qa Dia. Fitting F tng's Pe Pv •**•►•+ Notes ""''' or Pn Ref. C Total Pf Point Qt Pf1Ft Eqv. Ln. 6 0.0 1.442 0.0 14.000 23.070 20 0.0 0,0 0.0 Vel = 4.13 to 120 0.0 14.000 -0.424 7 -21.01 -0.0303 0.0 95,000 22.646 7 0.0 120 0.0 0.0 -0.901 120 98.000 -2.967 Vel = 4.13 to 0.0 KFactor @node EQ01 39 -21.01 - 0.0303 0.0 11.750 18.778 39 23.71 1 0.0 0,0 0.0 Vel = 0.53 to 0.0 0.0 11.750 0.008 40 2.7 0.0007 18.786 KFactor @node EQ01 1T 7.432 5.580 40 23.72 1 0.0 7.432 0.901 Vel = 5.15.19 - to 120 0.0 13.012 0.602 52 26.42 0.0463 0.289 to 45.44 1.442 1T 7.432 2.080 2 0.0 52 120 0.0 7.432 0.801 Vel = 14.12 _ 71.86 0.2945 0,0 9.512 0.0 71286 -. 23.090 !_.__,_ _ KF = 14.95 25 -3.92 1.442 4E' 14.864 146.660 23.909 0.0 9 _3,92 -0.0014 120 4T 29.728 44.592 Vel = 0.77 to 0.0 191.252 -0.259 K Factor = -0.81 0.0 _ .. 23.650 .. - - -- -- -- __ .... - -- -3.92 -- 24.092 2.24 1.442 4E 14.864 146.330 p.0 24 4T 29.728 44.592 Vel = 0.44 to 0.0 0. 0 190.922 0.091 10 2,24 _ 0.0005 2 2 24.183 2.24 _._- -� -- 25.704 23 -10.10 1.442 3T 22.296 133.330 0.0 120 0.0 22.296 Vet = 1.98 to 0.0 155.626 -1.214 33 -10.1 -0.0 90 to 4.4 33 6.36 1.442 4T 29.728 102.120 24.490 120 0.0 29.728 -0.064 Vel = 0.73 -3.74 -0.001 24.326 34 9.24 1 0,0 131.848 3T 22.296 137.830 34 120 0.0 22.296 0 . 0 Vel = 1.08 to 120 0.0 160.126 0.406 _.__ 11 5.5 0.00 _ 0.0 24.732 KFactor = 1.11 5.50 -�- - 2.000 22.910 15 -71.46 1.442 1 T 7.432 7.432 0.0 120 -0.049 Vet = 14.0 to 0.0 9 .432 _.. - -- - -.. 51 -71.46 -0.2915 51 45.33 1.442 1T 7.432 5.580 261 0.1 0.166 120 0.0 7.432 Vel = 5.13 to 0.0 13.012 -0.590 36 - 26.1_ _ -0.0453 00 0 11.750 18.705 K Factor © node EQ01 to o6 23.66 1.442 0 0.0 0 . 0 35 '2.47 - 00'0.0 006 -. Vel = 0.49 0. 0 11.750 -0.007 _ 18.698 KFactor @node EQ01 35 23.67 1.442 2T 14.864 119.660 p 866 16 21.2 0.0308 120 0.0 14.864 Vel = 4.16 to 0.0 134.524 4.140 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 • Final Calculations - Standard DELTA FIRE. INC. Page 7 FANNO CREEK BUILDING "A" L3 Date 070207 • Hyd. Qa Dia. Fitting Pipe Pt Pt E. Ref. "C" or Ftng's Pe Pv '"** * ** Notes **'*** Point Qt Pf /Ft Eqv. Ln. Total Pf Pn 16 0.0 2.157 0.0 11.620 23.704 to 120 0.0 0.0 0.0 28 21.2 0.0043 0.0 11.620 0.050 Vel = 1.86 28 21.01 2.157 0.0 10.000 23.754 to 120 0.0 0.0 0:0 25 42.21 0.0155 0.0 10.000 0.155 Vel = 3.71 25 3.92 2.157 0.0 10.000 23.909 to 120 0.0 0.0 0.0 24 46.13 0.0183 0.0 10.000 0.183 Vel = 4.05 24 -2.24 2.157 0.0 10.000 24.092 to 120 0.0 0.0 0.0 17 43.89 0.0166 0.0 10.000 0.166 Vel = 3.85 17 -9.23 2.157 0.0 9.500 24.258 to 120 0.0 0.0 0.0 31 34.66 0.0107 0.0 9.500 0.102 Vel = 3.04 31 -9.48 2.157 0.0 11.500 24.360 to 120 0.0 0.0 0.0 32 25.18 0.0060 0.0 11.500 0.069 Vel = 2.21 32 -9.08 2.157 0.0 11.000 24.429 to 120 0.0 0.0 0.0 18 16.1 0.0025 0.0 11.000 0.028 Vel = 1.41 18 -6.36 2.157 0.0 9.950 24.457 to 120 0.0 0.0 0.0 19 9.74 0.0011 0.0 9.950 0.011 Vel = 0.86 19 0.0 1.442 4T 29.728 139.000 24.468 to 120 0.0 29.728 0.0 20 9.74 0.0073 0.0 168.728 1.232 Vel = 1.91 20 0.0 2.635 0.0 9.950 25.700 to 120 0.0 0.0 0.0 23 9.74 0.0004 0.0 9.950 0.004 Vel = 0.57 23 10.10 2.635 0.0 10.000 25.704 - - - - - _ _ - to 120 0.0 0.0 0.0 21 19.84 0.0015 0.0 10.000 0.015 Vel = 1.17 21 9.08 2.635 0.0 11.500 25.719 to 120 0.0 0.0 0.0 22 28.92 0.0029 0.0 11.500 0.033 Vel = 1.70 22 9.47 2.635 1T 16.474 7.620 25.752 to 120 0.0 16.474 0.0 12 38.39 0.0049 0.0 24.094 0.118 Vel = 2.26 0.0 38.39 25.870 K Factor = 7.55 HOSE . 100.00 6.16 1T 43.037 15.000 53.467 Qa = 100.00 • to 140 0.0 43.037 - 14.076 14 100.0 0.0003 0.0 58.037 0.020 Vel = 1.08 _ 0.0 • 100.00 39.411 K Factor = 15.93 15 71.46 2.635 0.0 11.620 22.910 to 120 0.0 0.0 0.0 8 71.46 0.0155 0.0 11.620 0.180 Vel = 4.20 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard DELTA FIRE, INC. Page 8 ` FANNO CREEK BUILDING "A" L3 Date 070207 Hyd. Qa Dia. Fitting Pipe Pt Pt • Ref. "C" or Ftng's Pe Pv * * *** ** Notes **"* ** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 8 71.87 2.835 0.0 10.000 23.090 to 120 0.0 0.0 0.0 9 143.33 0.0560 0.0 10.000 0.560 Vel = 8.43 9 -3.92 2.635 0.0 10.000 23.650 to 120 0.0 0.0 0.0 10 139.41 0.0533 0.0 10.000 0.533 • Vel = 8.20 10 2.24 2.635 0.0 10.000 24.183 to 120 0.0 0.0 0.0 11 141.65 0.0549 0.0 10.000 0.549 Vel = 8.33 11 5.50 2.635 IT 16.474 2.870 24.732 to 120 0.0 16.474 0.0 12 147.15 _ 0.0588 0.0 19.344 1.138 Vel = 8.66 12 38.39 2.635 2E 16.474 55.330 25.870 to 120 0.0 16.474 13.357 BOR 185.54 0.0904 0.0 71.804 6.489 Vel = 10.92 BOR 0.0 2.635 1 E 8.237 32.160 45.716 to 120 1B 9.61 , 26.084 - 13.210 TOR 185.54 0.0904 1Z 8.237 58.244 5.265 Vel = 10.92 TOR 0.0 4.26 6E 79.002 111.870 37.771 to 120 0.0 79.002 -0.147 13 185.54 0.0087 0.0 190.872 1.662 Vel = 4.18 13 0.0 6.16 1 E 20.084 95.000 39.286 to 140 0.0 20.084 0.0 14 185.54 0.0011 0.0 115.084 0.125 Vel = 2.00 14 100.00 6.16 1 E 20.084 275.000 39.411 to 140 0.0 20.084 14.076 DDVC 285.54 0.0024 0.0 295.084 0.712 Vel = 3.07 DDVC 0.0 6.16 0.0 50.000 54.199 to 140 0.0 0.0 5.000 * Fixed loss = 5 TEST 285.54 0.0024 0.0 50.000 0.120 Vel = 3.07 0.0 285.54 59.319 K Factor = 37.07 r Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Ida RECEIVED AUG 31 2007 CITY OF TIGARD BUILDING DIVISION INC. ELIA FIRE FIRE PROTECTION CONTRACTORS 14116 SU,11it PO RAID, OR 11224 (SDJ) 620-00 DELTA FIRE, INC. 14795 SW 72nd Ave. Portland, OR 97224 503 620 -4020 Job Name : FANNO CREEK BUILDING "A" L3 Building : "A" Location : UPPER BOONES FERRY RD. AND SW 72ND (FANO CREEK) System : 01 Contract : 06 -3534 Data File : FANNAL3 -.wx1 • Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 DELTA FIRE, INC. FANNO CREEK BUILDING "A" L3 ' Page 1 Date 070207 Hydraulic Design Information Sheet Name - FANO CREEK PLACE BUILDING "A" Location - UPPER BOONES FERRY RD. AND SW 72ND (FANO CREEK) Date - Building - "A" Contractor - OPUS NW System No. - 01 Calculated By - MICHAEL STEWART Contract No. - 06 -3534 Construction: ( ) Combustible Drawing H Occupancy - LIGHT HAZARD (X) Non - Combustible Ceiling Height - 9'-0" S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure S Other Curve T Specific Ruling Made By Date E M Area of Sprinkler Operation - - - -- Density - . System Type Sprinkler /Nozzle D Density Per Sprinkler (X) Wet Make RELIABLE E Elevation at Highest Outlet - 31' -2" ( ) Dry Model Model Fl/FR 2" ( ) ration S Hose Allowance - Inside - 100 ( ) Deluge K - F a tor" I Rack Sprinkler Allowance ( ) Other T em actor 5.62 G Hose Allowance - Outside - 0 p.Rat.155 N Note ROOM DESIGN NFPA2002 11.2.3.3.6 Calculation Flow Required - 222.9 Press Required - 58.2 Summary C- Factor Used: 120 Overhead 140 Underground W Water Flow Test: Pump Data: A Date of Test - 08/02/2006 Tank or Reservoir: T Time of Test - NA Rated Cap.- e v . - p ' E Static Press - 106 Elv- R Residual Press - 102 @ Press - Flow 1807 Elev. - Well Proof Flow S Elevation - 0 U P Location - SW 72ND AVE AND UPPER BOONES FERRY RC - P L Source of Information - CITY OF TIGARD Y C Commodity Class O Storage Ht. Location M Storage Method: Solid Piled Area Aisle W. M Palletized $ Rack ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet T A ( ) Mult. Row ( ) Solid Shelf ( ) Non O C ( ) Open Shelf R K Spacing Flue ing A Lu Spacing Clearance:Storage to Ceiling G Transverse E Horizontal Barriers Provided: • Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'a Water Supply Curve (C) DELTA FIRE, INC. FANNO CREEK BUILDING "A" L3 Page 2 Date 070207 City Water Supply: C1 - Static Pressure 106 C2 - Residual Pressure: 102 Demand: : 122.994 C2 - Residual Flow : 1807 D1 - Elevation D2 - System Flow • 13.495 D2 - System Pressure 58.200 Hose (Adj City ) Hose ( Demand) : 100 D3 - System Demand : 222.994 Safety Margin : 47.716 IIIIMIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII _ 140 130 �__ p 120 R 110 , I�-__ E 100 l_ _ -` _ S 9° IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIMIIIIIIII S 80■- U 70 �■-__ �-__ R 60 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIMIIIIIIIIII E 50 i'� __ 3 20 -__ 11111111111111 1° 1111111111111111.111111111111111111.1111111111111111111.11.1111111.1111.111111111111. 200 4 11111111111111111111111111111111111111111111111111111111■11.1 00 600 800 1000 1200 1400 FLOW (N A 1.85) 1600 1800 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary DELTA FIRE, INC. FANNO CREEK BUILDING "A" 13 Page 3 Fitting Legend Date 070207 Abbrev. Name ' �' % 1 1% 1% 2 2% 3 3% 4 14 18 5 6 8 10 12 18 20 24 t3 Generic Butterfly Valve 0 0 0 Generic Elbow 2 2 0 0 0 7 100 12 9 T 90' Flow and Tee 2 3 4 5 6 7 8 10 12 14 12 19 21 0 0 0 0 0 Z Generic Flow Switch 2 2 3 4 5 6 8 10 12 15 17 20 25 30 35 41 95 121 27 35 50 61 2 3 4 5 6 7 50 60 3 4 45 91 50 61 8 10 12 14 18 22 27 35 40 45 50 g1 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 T Pressure / Flow Summary - STANDARD • DELTA FIRE, INC. FANNO CREEK BUILDING "A" L3 Page 4 • Date 070207 Node Elevation IC Fact Pt Pn Flow Density Area Press No. Actual Actual Req. . D001 32.5 5.62 16.03 na 22.5 17 32.5 30.18 na 0.1 225 7.0 18 32.5 30.45 32 32.5 na 31 32.5 30.31 na 30.31 30 31.16 K = K @ EQ01 17.08 n g 29 31.16 K = K @ EQ01 18.87 na 24.05 5 32.5 24.05 27 • . 31.16 K = K @ EQ01 23.39 na 28 31.16 K = K @ EQ01 23.4 na 26.78 25 32.5 na 26.78 24 32.5 29.92 na 29.92 na 23 32.5 32.05 na 33 32.5 30.49 na 34 32.5 8 32.5 30.34 na 15 32.5 31.61 na 36 34.5 31.6 na 35 34.5 30.4 .4 na 16 32.5 30.22 na 29.0 28 32.5 na 19 32.5 29.06 6 na 30.46 na 20 32.5 32.05 na 21 32.5 32. 22 32.5 na HOSE 0.0 32.112 2 na 52.65 na 1 31.18 K = K EQ01 2 32.5 @ 16.51 na 1 22.5 3 32.5 16.81 na 4 32.5 17.4 na 6 32.5 19.27 na 7 32.5 24.02 na 39 34.58 24.03 na 29.42 na 40 34 32.5 29.42 na 9 9 10 32.5 31.67 na 11 31.77 na 32.5 12 32.5 11 31.91 na BOR 1.66 32.27 na 4 TOR 32.16 37.9 na • 38.5 13 32.5 na 14 32.5 38.54 4 na 38.6 DDVC 0.0 58.2 na na TEST 0.0 58.22 na The maximum velocity is 18.33 and it occurs in the pipe between nodes 5 and 28 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen - Williams • DELTA FIRE, INC. • FANNO CREEK BUILDING "A" L3 Date 070207 Ref Qa ape Pt Pt "DiC. Fitting Pi " Point Qt Pf /Ft Eqv. Ln. Total Pe Pv "* *"** Notes *** Pf Pn • D001 22.50 1.049 1 E 2.0 to 120 1.000 16.029 K Factor = 5.62 EQ01 22.5 0.1617 0 ' 0 2.000 0.0 0.0 3.000 0.485 0.0 Vel = 8.35 22.50 17 14.99 1.442 16.514 ' • K Factor = 5.54 to 1 T 7.432 2.830 30.177 120 0.0 7.432 14.99 0.0162 0.0 0.0 10.262 0.186 Vef = 2.94 0.0 _ 14.99 18 7.98 1.442 30.343 K Factor = 2.72 to 1 T 7.432 2.330 30.445 33 120 0.0 7.432 7.98 0.0050 0.0 0.0 9.762 0.049 __ -- Vel = 1.57 0.0 - -• -- 7.98 � - - 32 10.43 1.442 30.494 K Factor = 1 _ to 2E 7.432 149.250 30.406 -- 120 6T 44.592 52.024 21 _ 10.43 0.0083 00201 .274 0.0 0.0 10.43 _ 1.667 Vel = 2_05 - • 31 10.90 1,442 32.073 K Factor = 1.84 to 4E 14.864 156.160 30.313 120 4T 29.728 44.592 _ 22 10.9 0.0090 0.0 0.0 200.752 1.803 0.0 Vel = 2.14 _ 10.90 30 ____ 1.049 1 T 5 0 - - - - -_- - _ _ 32.116 K Factor = 1.92 to 120 0.410 17.082 K Factor @node EQ01 3 22.88 0.1669 0.0 5.000 -0 5.000 -0.580 0.0 5.410 0.903 0.0 _ Vel = 8.49 22.88 - -- - -- - - - -- - 29 24.05 1,049 17.405 K Factor = 5.48 to 1 T 5 . 0 0.410 18.865 120 0.0 5.000 K Factor @ node EQ01 -0.580 4 24.05 0.1830 0.0 _ _ 0,_0_ . - _5.410 0.990 Vel - 8.93 24.05 - - -- 5 93.33 1.442 19.275 K Factor = 5.48 to 1 T 7.432 2.080 24.522 28 120 0.0 7.432 93.33 0.4775 0.0 0.0 . - - 9.512 4.542 Vel = 18.33 0.0 - 93.33 27 26.78 1.049 29.064 K Factor = 17.31 to 1 T 5 . 0 0.410 23.391 6 120 0.0 5.000 K Factor @ node EQ01 -0.580 26.78 0.2233 --- 0.0 5.410 1.208 Vel = 9.94 0.0 _ 26.78 - 26 26.78 1.049 - -- 4.019 K Factor = 5.46 2 to 1 T 5 . 0 0.410 23.401 K Factor @ node EQ01 7 120 0.0 5.000 26.78 0.2233 -0.580 0.0 5.410 1.208 Vel = 9.94 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard DELTA FIRE. INC. FANNO CREEK BUILDING "A" L3 Page 6 Date 070207 Hyd. Qa Dia. Fitting Pipe • 'V' or Pt Pt Ref. � Point Qt Pf /Ft Eqv. Ln. Total Pe Pn ***wail** Notes 0.0 26.78 25 12.19 1.442 24.029 K Factor = 5.46 to 4E 14.864 146.660 29.558 120 4T 29.728 44.592 9 12.19 0.0110 P.O 191.252 0.0 0.0 2.113 Vel = 2.39 12.19 24 11.35 1.442 31.671 K Factor = 2.17 to 4E 14.864 146.330 29.920 10 120 4T 29.728 44.592 11.35 1 0.0097 0.0 190.922 0.0 0.0 1.850 Vel = 2.23 11.35 23 -11.56 1.442 31.770 __ _ K F 2.01 to 3T 22.296 133.330 32.055 33 120 0.0 22.296 -11.56 -0.0100 0.0 155.626 0.0 33 7.98 1.442 -1.561 Vel = 2.27 to 4T 29.728 102.120 30.494 - -- - -- 120 0.0 29.728 34 -3.58 - 0.0011 0.0 131.848 • 0.0 14.99 1.442 • - • -- -0:151 Vel = 0.70 to 3T 22.296 137.830 30.343 120 0.0 22.296 11 - 11.41 0.0098 0.0 0.0 160.126 1.566 0.0 Vel = 2.24 11.41 8 -14.31 2.635 31.909 K Factor = 2.02 to 0.0 11.620 31.608 120 0.0 0.0 15 -14.31 -0.0008 0.0 11.620 0.0 � -0.009 Vel = 0.84 15 0.0 1.442 to 2T 14.864 7.580 31.599 36 120 0.0 14.864 -0.866 -14.31 - 0.0149 36 _ 0 . 0 22.444 _ -0.334 Vet = 2.81 0.0 1.442 0.0 11.750 - 30.399 to 120 - 3 �14.31 - 0.0149 0.0 0.0 0.0 = 35 - - -- 0. 11.750 -0.175 0.0 1.442 2T 14.864 119.660 Vel 2.81 to 120 0.0 14.864 30.866 16 -14.31 __ - 0.0149 0 134.524 0.006 16 0.0 2.157 0 -- -2.002 Vel = 2.81 to 2.1 . 11.620 29.088 28 -14.31 -0 .0021 0 0 0.0 0.0 28 0 . 0 11.620 -0.024 93.33 2.157 0.0 10.000 Vel = 1.26 to 120 20.064 279.02 0.0494 0.0 0.0 0.0 25 0.0 10.000 0.494 -12.19 2.157 01 000 - Vel = 6.94 0.0 29.558 to 120 0.0 0.0 24 66.83 0.0362 0.0 24 0.0 10.000 0.362 -11.35 2.157 0.0 10.000 Vel = 5.87 to 120 29.920 - - - _ 17 55.48 0.0257 0 0 0.0 0.0 0.0 10.000 0.257 Vel = 4.87 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard ` DELTA FIRE, INC. i. FANNO CREEK BUILDING "A" L3 Page 7 Date 070207 Hyd. Qa Dia. Fitting Pipe Pt Pt • Ref. "C" "C" Point Qt Pf /Ft Eqv. Ln. Total als Pf Pe Pv '•" Notes `* *► Total Pn 17 -14.99 2.157 0.0 9.500 to 120 - 30.177 31 40.49 0.0143 0.0 0.0 0.0 0 . 0 9.500 0.136 Vel = 3.55 31 -10.89 2.157 0.0 11.500 30.313 to 120 0'0 . ' 0.0 0.0 32 29.6 0.0081 0.0 11.500 0.093 32 -10.43 2.157 0.0 11.000 Vel = 2.60 to 120 30.406 18 19.17 0.0035 0.0 0'0 0.0 0.0 11.000 0.039 .950 Vel = 1.68 18 -7.98 2.157 0.0 9 to 120 30.445 19 11.19 0.0013 0.0 0'0 0.0 -- 0.0 9.950_ 0.013 19 0.0 1.442 4T 29.728 139.000 30.458 Vel = 0.98 to 120 0.0 29.728 20 11.19 0.0094 0.0 0.0 168.728 1.592 20 0.0 2.635 0.0 9.950 Vel = 2.20 to 120 32.050 23 11.19 0.0005 0.0 0 ' 0 0.0 0.0 9.950 0.005 23 11.56 2.635 0.0 10.000 . - - _ _ Vel =__ 0.66 to 120 32.055 . 21 22.76 0.0018 0 0 0.0 0.0 0.0 10.000 0.018 2 1 10.43 2.635 0.0 11.500 32.073 Vel = 1.34 to 120 _22 33.18 0_0037 0.0 0.0 0.0 0.0 11.500 0.043 22 10.89 2.635 1T 16.474 7.620 Vel = 1.95 to 120 32.116 -- -- 12 0 . 0 16.474 0.0 44.07 0.0064 0. 0.0 24.094 0.153 Vel = 2.59 44.07_ 32'269 K Factor = 7.76 HOSE 100.00 6.16 to 1T 43.037 15.000 52.653 140 0.0 43.037 - 14.076 Qa = 100.00 14 100.0 0.0004 _ 0.0 58.037 0.0 0.021 Vel = 1.08 100.00 1 22.50 1.049 38.598 K Factor = 16.10 1T 5.0 0.410 16.514 to 120 0.0 5.000 K Factor @ node EQ01 -0.580 2 22.5_ 0.1617 2 0 . 0 5.410 0.875 Vel = 8.35 0.0 1.38 0.0 14.000 to 120 16.809 _ 3 22.5 0.0426 0.0 0'0 0.0 0.0 14.000 0.596 3 22.88 1.38 0.0 12.000 Vel = 4.83 to 120 17.405 4 __. 4 . 5.38 01558 0 � 0 0 ' 0 0.0 _ 0_0 . _ 12.000 1.870 4 24.05 1.38 1T 6.0 _ Vel = 9.73 - --- - - - . to 120 9.330 19.275 � ' 5 69.43 120 0.0 6.000 0.0 0.0 15.330 5.247 5 -93.33 1.442 1T 7.432 5.660 24.522 Vet = 14.89 to 120 0.0 7.432 6 -23.9 -0.0384 0.0 0.0 13.092 -0.503 Vel = 4.70 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I Final Calculations - Standard DELTA FIRE, INC. h. FANNO CREEK BUILDING "A" L3' Page 8 Hyd. Qa Dia. Date 070207 • Ref. qC „ Fitting Pipe Pt Pt Point Qt Pf or Total Pe Pv ***+ Eqv. Ln. Pf P Notes 6 26.78 1.442 to 120 0.0 14.000 24.019 7 2.88 0.0007 0.0 0.0 0.0 0 . 0 14.000 0.010 26.78 1.442 Vel = 0.57 7 to 120 0.0 98.000 24.029 39 29.66 0.0573 0.0 0'0 -0.901 39 0 . 0 98.000 5.615 0.0 1.442 Vel = 5.83 to 1 ZO 0.0 11.750 28.743 40 29.66 1 0574 0.0 0.0 0.0 40 0.0 1.05 0 . 0 11.750 0.674 2T 14.864 7.660 Vel = 5.83 to 120 29.417 8 29.66 120 0573 0.0 14.864 0.901 8 14.32 2.05 0'0 22.524 1.290 Vel = 5.83 to 120 0' 0 10.000 31.608 9 43.98 0.0063 0.0 0' 0 0.0 g 0 . 0 _ 10.000 _ 0.063 12.18 2.635 0.0 10.000 Vel = 2.59 to 120 31.071 0.0 0.0 0.0 10 56.16 0.0099 0.0 10.000 0.099 Vel = 3.30 10 11.35 2.635 0.0 10.000 to 120 31. 11 67.51 0.0139 0.0 0.0 0.0 11 0.0 10.000 _ _ 0.139 11.41 2.635 1 T 16.474 - Vel = 3.97 to 120 2.870 31.909 12 8_92 0.0186 0.0 16.474 0.0 12 44.07 2.635 0.0 19 - - 0.360 Vel = 4.64 2E 16.474 55.330 to 120 32.269 _. BOR 122.99 0.0422 0.0 16.474 13.357 0.0 71.804 3.033 BOR 0.0 2.635 1E 8.237 32.160 Vel = 7.24 to 120 48.659 20 ] B 9.61 - TOR 122.99 10423 26.084 - 13.210 1Z 8.237 58.244 2.461 TOR 0.0 4.26 6E 79.002 111.870 VeI = 7.24 to 120 37.910 .. - 13 122.99 0.0041 _ 0.0 79.002 -0.147 13 0 . 0 190.872 0.776 0.0 6.16 1E 20.084 95.000 38.539 Vel = Z,77 to 140 14 122.99 0.0 0.0 20.084 0.0 005 0 ' 0 115.084 _ 0.059 Vel = 1.32 14 100.00 6.16 1E 20.084 275.000 to 140 0.0 20.084 14.076 38.598 . -- DDVC 222.99 140 DDVC - 0 . 0 295.084 0.450 0.0 6.16 0.0 50.000 Vel = 2.40 to 140 53.124 TEST 222.99 0.0015 0.0 0.0 5.000 0.0 50.000 0.076 * Fixed loss = 5 0.0 Vel = 2.40 � X22_99 - ________ 58.200 K Factor = 29.23 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 •