Correspondence City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223
September 28, 2007
•
RE: MECHANICAL TI
Proiect Information TBaAD
Building Permit: MEC2007 -00549 Construction Type: 5 -1 hr
Tenant Name: Holiday Inn Express Occupancy Type: R -1
Address: 15700 SW Upper Boones Ferry Occupant Load: NA
Area: NA Stories: 3
The plan review was performed under the State of Oregon Mechanical Specialty Code
(OMSC) 2007 edition; and the State of Oregon Fire Code (OFC) 2007 edition. The
following corrections need to be submitted for review prior to issuing of the permit
1) • • • - • - _ • es opping or duct penetrations i - • • . " • =
it
;A ,
2) Pr• • - _ • . - w - U on a roof. 11: c
3) •_ - _ - • - . - • - . pen- - • corn.. • r. -. i.• -- = - - = . 1204k3
' II i • '•• • - • - - -_. .. -• \ Atsfkki
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter -of- Transmittal: The assists the City.
of Tigard in tracking processing the documents.
Respectfully
0 4.P
A,, watt
- n Nelson,
Senior Plans Examiner
• . Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772
•
- City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 fY ,
October 18, 2007
RE: MECHANICAL
Project Information KT.
Building Permit: MEC2007 -00549 Construction Type: 5 -A
Tenant Name: Holiday Inn Express Occupancy Type: R -1
Address: 15700 SW Upper Boones Ferry Occupant Load: NA
Area: NA Stories: 3
The plan review was performed under the State of Oregon Mechanical Specialty Code
(OMSC) 2007 edition; and the State of Oregon Fire Code (OFC) 2007 edition. The
submitted plans are approved subject to the following.
1. Ductwork shall be supported in accordance with Sheet Metal & Air Conditioning
Contractors National Association, Inc. (SMACNA)
2. Each appliance shall be provided with a shutoff valve separate from the
appliance. The shutoff valve shall be located in the same room and within six feet
of the appliance served. Access shall be provided to the shutoff valve. C409.5
OMSC
3. Equipment and appliances regulated by this code requiring electrical connections
shall have a positive means of disconnect in accordance with the Electrical Code.
301.7 OMSC
4. Permanent equipment supported by the structure, 400 lbs and over, shall have
their attachments designed in accordance with the Building Code. 301.16 OMSC
5. Appliances shall be accessible for inspection, service, repair or replacement
without removal of permanent construction. 306.1 OMSC
6. Manufacturer's installation instructions shall be available on the jobsite at the
time of inspection. 304.1 OMSC
7. Condensate from cooling coils or evaporators shall be collected and discharged
to an approved plumbing fixture or disposal area. 307.1 OMSC
8. Every refrigerant - containing part of every system that is erected on the premises
shall be tested and proved tight after complete installation, and before operation.
Tests shall include both the high and low- pressure sides of each system.
13. Fire and smoke dampers shall be provided with an approved means of access,
large enough to permit inspection and maintenance of the damper and its
- operating parts. Access points shall be permanently identified on the exterior by
•
Phone: 503.639.4171 • Fax: 503.684.7297 . • www.tigard or.gov • TTY Relay: 503.684.2772
a label. Access doors in ducts shall be tight fitting and suitable for the required
duct construction.
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp,
shall be maintained on the jobsite. The plans shall be available to the Building Division
inspectors throughout all phases of construction. 106.4.2 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new
buildings in such a position as to be plainly visible and legible from the street or road
fronting the property.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City
of Tigard in tracking and processing the documents.
Respectfully,
an Nelson,
Senior Plans Examiner
•