Loading...
Specifications t Fire Protection Services, Inc. 5573 SW Arctic Drive. Beaverton, Oregon 97005 LY) Phone: (503) 590 -3732 r _ Fax: (503) 628 -6214 /5 7 � � A � z I p_ SHERWOOD INN AND SUITES 15700 S.W UPPER BOONES FERRY RD LAKE OSWEGO, OR 97035 FIRE ALARM DESCRIPTION DESCRIPTION An automatic fire protection system will be installed utilizing an Addressable control panel and providing for monitoring of Smoke Detectors, Heat Detectors, Manual Pull Stations, Waterflow and Tamper Devices. The interior Piezos, and Horns / Strobes will be mounted at 84" to the bottom of the device. The Pull Station will be mounted at 48" to the center of the device. Smoke and Heat detectors will be ceiling mounted. All NAC power supply and addressable devices will be connected to main fire alarm system via addressable loop. All audible devices will sound in the ANSI temporal pattern. All strobe flashes will be synchronized where applicable. Primary power to the panel shall be 110 VAC power with a 24VDC 7AH battery back -up. All fire alarm circuits will be wired with 16 gauge FPLR/CMR red cable with the exception of NAC circuits, which will be wired with 14 gauge FPLR/CMR red cable. Monitoring will be provided through Alarm Central Station, a U.L. listed monitoring company (503.641.6761) All installation will be done according to N.F.P.A. 72 standard. Work will be performed in a neat and professional manner. All work will be performed according to the timeline set. All equipment will be UL listed and approved for the application. SYSTEM COMPONENTS Silent Knight 5820XL FACP Silent Knight 5496 Power Modules EIVED Silent Knight 5860 Remote Annunciator RECEIVED Silent Knight SD- 500 - Arm,MIM, and ANM Modules Silent Knight SD505 -APS Smoke Detector AUr 0 P Silent Knight SD500 -PS Pull Stations Silent Knight SD505 -AHS Mechanical Heat Detectors OF•TKIARD Gentex GX -93 Piezos SUILDINGDIVISIO Gentex Commander GEC3 Horn Strobes Wheelock 43T 6" Bell 4. tt - Global Project Values: c o SILENT Project Name:ISherewood Inn Standby Hours:1 24 KNIGHT Project 10:12463 I Alarm Mins: 5 Prepared By: David m Phipps Derating Factor: 1 2 1 5820XL Calculations Date: 8/6/2007 ( Voltage Drop Warning Threshold % :I 10 Panel ID: 5820XL Model: 5820XL Add. Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: 12nd floor closet Volts: 24 VDC Max Panel Current: 5.0 Amps Ckt.# Circuit Name Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & T .e 1000 Ft. One -Wa Ohms EOL 5820XL 5820XL CTRL Panel 1 0.140 0.260 SLC -DEV Addrsbl SLC Devices 61 0.003 0.034 5815XL SLC Loop Expander 0.000 0.000 5860 LCD Remote Annunc 1 0.020 0.025 5824 Serial /Parallel Module 0.000 0.000 5895XL Power Expander 0.000 0.000 5865 -4 LED Annunciator (4G) 0.000 0.000 5865 -3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 SD505 -6SB Sounder Base 0.000 0.000 SD505 -6RB Relay Base 0.000 0.000 SD -Duct Duct Hsg w /Relay 0.000 0.000 5883 Relay Module 0.000 0.000 PGM -I /O #1 Floor 1 Nac 0.000 1.175 #14 Solid 2.52 200 1.01 22.82 4.94% PGM -I /O #2 Floor 1 Nac 0.000 1.200 #14 Solid 2.52 200 1.01 22.79 5.04% PGM -I /O #3 Basement Nac 0.000 1.412 #14 Solid 2.52 200 1.01 22.58 5.93% PGM -I /O #4 Aux Power Circuit 0.000 0.000 #14 Solid 2.52 200 1.01 24.00 0.00% PGM -I /O #5 Notification Appl Circuit 0.000 0.000 #12 Solid 1.59 0.00 24.00 0.00% PGM -I /O #6 Notification Appl Circuit 0.000 0.000 #12 Solid 1.59 0.00 24.00 0.00% Total Standby Current (Amps) 0.163 4.106 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 3.921 0.342 Total Alarm AH Required Total Combined AH Required 4.26 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 5.12 C Configure Circuits Print Pis i la hM( T Circuit Configuration - Project Information Project Name: Sherewood Inn Project ID: 2463 - Prepared By: David m Phipps Date: 8/6/2007 Ckt. Number: PGM -I /O #1 Panel ID: 5820XL Ckt. Name: Floor 1 Nac I/O Use: Notification Appi Circuit v Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 Gentex Commander 3 24v Horn / Strobes 0.000 0.212 0.000 0.848 2 Gentex Commander 3 24v Strobes 0.000 0.076 0.000 0.152 7 Gentex GX -93 Mini -Horn Peizo 0.000 0.025 0.000 0.175 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.175 Ckt. Number: PGM -I /O #2 Panel ID: 5820XL Ckt. Name: Floor 1 Nac I/O Use: Notification Appi Circuit ■ Qty Device Current Draw Each Current Draw Total Standby _ Alarm Standby Alarm 4 Gentex Commander 3 24v Horn / Strobes 0.000 0.212 0.000 0.848 2 Gentex Commander 3 24v Strobes 0.000 0.076 0.000 0.152 8 Gentex GX -93 Mini -Horn Peizo 0.000 0.025 0.000 0.200 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.200 Ckt. Number: PGM -I /O #3 Panel ID: 5820XL Ckt. Name: Basement Nac I/O Use: Notification Appl Circuit ■ Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 Gentex Commander 3 24v Horn / Strobes 0.000 0.212 0.000 1.060 2 Gentex Commander 3 24v Strobes 0.000 0.076 0.000 0.152 8 Gentex GX -93 Mini -Horn Peizo 0.000 0.025 0.000 0.200 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.412 I SILENT [NIGH'' Circuit Configuration Project Information Project Name: Sherewood Inn Project ID: 2463 Prepared By: David m Phipps Date: 8/6/2007 Ckt. Number: PGM -I /O #4 Panel ID: 5820XL Ckt. Name: Aux Power Circuit I/O Use: Aux Power Circuit N. II Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000' Unused 0.000 0.000 0.000 0:000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 _ 0.000 I 0.000 0.000 Totals 0.000 0.000 Ckt. Number: PGM -I/O #5 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use Notification Appl Circuit ■ Current Draw Each Current Draw Total Q =y Device Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused :0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: PGM -I /O #6 °�� " Panel ID: 5820XL Ckt.' Name: Notification Appl Circuit I/O Use Notification Appl Circuit ■ Qt Device Current Draw Each Current Draw Total sY Standby Alarm Standby Alarm Unused 0.000 0.000 0.000' 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 - clobatt i'oject Values: • • SILENT Project Name. Sherwood Inn Standby Hours: 24 I t. KNIGHT Project ID: 2463 I Alarm Mins:. 5 Prepared By: David M phipps I Derating Factor: 1.2 5496 Power Expander Calculations Date: 8/6/2007 Voltage Drop Warning Threshold % :' 10 ............................................... ............................... . Panel €Q ;'5496(1) Old Bldg I Model: Silent Knight 5496 Power Expander Max Circuit Current: 3 Amps Location: 12nd floor Closet f Volts. 24 VDC Max Panel Current: 6 Amps :Current Draw W AWG Ohms Per Length(ft) Actual Volts Nt10 @ %Drop Cir uit 1:06. /Drop $tattdtiy Alarm ..& :Type 1000 Ft. One -Way Ohms EOL 1 3rd Floor In -room Peizo 0.000 0 525 #14 Solid 2 52 175 0.88 19 94 2.27% 2 3rd Floor Horn /Strobes 0.000 1.136 #14 Solid 2.52 225 1 13 19.11 6.31% 3 2nd Floor In -room Peizo 0.000 0.525 #14 Solid 2.52 225 1.13 19.80 2.92% 4 2nd Floor Horn /Strobes 0.000 1.000 #14 Solid 2.52 200 1.01 19.39 4.94% Aux 5496(1) Aux Power Out 0.000 0.000 #12 Solid 1 59 000 20,40 I 0.00% Aux, : P . "0.0 . : `1 # of NAC's Used 0.000 0.000 ....... 546 .60.6 Power Expander 0.040 0.160 3.186 (Amps) Total Output Power Required Tiitaal - Standby Current (Amps) 0.040 3.346 Tottll AtaFm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 0.960 0 7. ;;Total; Alarm AH Required Total Combtnett AH Required 1.24 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of . :•.: , :::::::::::::::::::*:Multiply:.:By<It*t kiiiitingiFiattor 1.20 the minimal difference between solid and stranded wire no differential was made. ...... . . ... . .. . ........ ........................................................................ . ................................ ...... . ......... . hireitirit a ery! : ; ours: egiitred 1.49 *1. A vallue must be entered if you havve selected a ny output as Aux. Power. Panel ID: 54959(2) New Bldg f Model: Silent Knight 5496 Power Expander Max Circuit Current 3 Amps Locatton;j2nd floor Closet Old Bldg 1 Volts 24 VDC Max Panel Current 6 Amps Ckt # Circuit Natrte Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type ..;.. 1000 Ft. One -Way Ohms InQI.... . 1 3RD FLOOR NEW BLDG 0.000 1.086 #14 Solid 2.52 200 1 01 4 t 5.37% 2 2ND FLOOR NEW BLDG 0.000 1.298 #14 Solid 2 52 200 1.01 19 Q9 6.41% 3 1ST FLOOR NEW BLDG 0.000 1 412 #14 Solid 2.52 200 1.01 18.98 6 98% 4 5496(2) Circuit 4 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% ALEX 5496(2) Aux Power Out 0.000 0.000 #12 Solid 1 59 0.00 20 40 0 00% Aux Power *1 # of NAC's Used 0.000 0.000 5496 5496 Power Expander 0.040 0,160, 3.796 (Amps) Total Output Power Required Total Standby Current (Amps) 0.040 31156 :> T itatiAlarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 0.960 , 0.330 Total Alarm AH Required .............. :Total Combined AH Required 1.29 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of . Mirtt0y By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Mtrytnt, rn Blattery! Required 1.55 *1. A vallue must be entered if you havve selected any output as Aux. Power. El SI KNIECHT Circuit Configuration Project Information Project Name: Sherwood Inn Project ID: 2463 Prepared By: David M Phipps Date: 8/6/2007 • Ckt Numbet : Panel ID: 5 496(1):;Qtd Btdg Ckt. Name rd.: #a ':In:=iroorrt.Peize Max Circuit Current 3 Ames w+ !M! , : :a w* Qty device C ltr : ent Draw Each Current Draw Total `Standby A4rm Standby Alarm 21 Gentex GX - 93 In Room Peizo Horn 0000 03025 0.000 0 525 Unused :f2,o46. .: ::::tf;flDQ 0.000 0.000 Unused : ::. >::::::666>:::.�.0.o 0.000 0.000 Unused ;> 0. t3O# 3`:.: ..:.0:00fk........::.;:.0;000 0.000 ...................... 0 00 0,000 Totals 0.000 0.525 Ckt. Number: 2 Panel ID: 5496(1) Old Bldg Ckt. Name: 3rd Floor Horn /Strobes Max Circuit Current 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 5 Gentex Commander 3 Horn / Strobes _ 0,000 0.212 0:000::::::::::::::: 1 Gentex Commander 3 Strobes 0.000 0.076 0:000:::::::::::::::::::0::::07.6. Unused 0.000 0 000 0.000 0.000 Unused .0.000 0.000 0.000 0.000 0.000 0:000 Totals 0.000 1 136 Ckt Number: 3 • Panei lD ;5496(1')' Old Bldg Ckt Name: 2nd Floor In -room Peizo Max Circuit Current: 3 Amps Qty Device Cun ent Draw Each`` Current Draw Total Standby Marm Standby Alarm 21 Gentex GX - 93 In Room Peizo Horn 0.000 ' 0.5 0.000 0 525 Unused 1000w:::.:: 0 000 00Ql3 Unused 0.000 0.000 0,000 Unused 0.000 0 00 •0.000 0.000 0:000 0.D0D 1: Totals 0.000 0.525 Ckt. Nurrrber 4 Panel I[7l •5496(1) Old PEdg Ckt. Name: 2nd Floor Horn /Strobes Max Circuit Current: 3 Amps.. Qty Device Current Draw teach Cutrent Dradv Total ,,, Alarm Sthl Standby dby Alar'rt . 4 Gentex Commander 3 Horn / Strobes 0 000 011:2 0.000 0.848 : 2 Gentex Commander 3 Strobes 0 000. : 0:::076 0,000 0.152 Unused 0 000 0 000 0 000 .0.000 T Unused 0,1;t0)1::::::. y, 0 000 0.000 •0.000 0.000 :: Totals 0.000 1.000 1 , Ckt Number: Aux Panel ID: 5496(1) Old Bldg Ckt. Name: 5496(1) Aux Power Out Max Circuit Current 3 Amps Qty Device Cui1.ent Dra*I aG Current Draw Total Standby _ Alarr Standby Alarm Unused 0;000 0.000 0.000 0.000 Unused •0.000 0.000 0. 000 0.000 Unused 0.000 0.000 D.O 0.000 0.000 Unused 0.000 0 :000 0.000 0.000 0.000 0.000 Totals 0 000 0.000 Ckt , 1 Panel ID_ 54959(2) New Bldg Gkt Name: 3RD FLOOR NEW BLDG Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 18 Gentex GX - 93 In Room Peizo Horn 0.000 0.025 D.000 0 450 3 Gentex Commander 3 Horn / Strobes 0.000 0.212 0.000 0 636 Unused ' 0000 0.000 0000 0.000 Unused OEl€ID :: 0.000 0 000 0 000 0.000 0.000 Totals 0.000 1.086 ............................. .......................... »G1�t •Number: 2 Panel ID 54959(2) New Bldg ::: >:::Ckt>::Nat e: >2ND:FLOOR NEW BLDG Max Circuit Current 3 Amps : : : ::. ::: . .. Current Drava Each Current Drava Total !:Device ................... .............................._ Standby Alarm Standby Alarm 18 Gentex GX - 93 In Room Peizo Horn 0 000 0 025 0 000 0 450_ 4 Gentex Commander 3 Horn / Strobes 0 000 0 212 0.000 0.848 Unused 0.000 0 000 0.000 0.000 Unused 0.000 0,000 0.000 0.000 0.000 0 000 Totals 0.000 1 298 ............... Ckt, .f ... ; ! Panel I 4959(2) New Bldg ... .............................. Ckt N t ST FLOOR NEW BLDG Max Circuit Current 3 Amps ..... ........................... ............................ Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 8 Gentex GX - 93 In Room Peizo Horn 0.000 0,025 0.000 0.200 5 Gentex Commander 3 Horn / Strobes 0.000 0 212 0,000 1.060 2 Gentex Commander 3 Strobes 0.000 0 076 0.000 0.152 Unused 0 000 0.000 0.000 0.000 0.000 0.000 :. • Totals 0.000 1 .412 INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight® Model 5820XL ,, Addressable Fire Alarm Control System ix . , (4', . ...: . The IntelliKnight System is the easy ,,,, ;''' way to make the most of fire alarm technology. IntelliKnight is the first fire alarm system to provide you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built -in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 - 446 -6444, or in Minnesota, call 612 - 493 -6435. Description programming rammin via PC. 9 9 3, >, The IntelliKnight 5820XL performs • Built -in digital communicator. drift compensation and calibration • Built -in Form C trouble relay checks on each of the sensors in rated at 2.5 amps at 24 VDC. _ the system. • Two built -in Form C The basic IntelliKnight 5820XL programmable relays rated at 2.5 1 system can be expanded by adding amps at 24 VDC. e ,,,., modules such as the Model 5860 • Uses standard wire —no shielded Remote Annunciator, Model or twisted pair required. a ; 5815XL Signalling Line Circuit • Supports Sounder Bases. Expander, the Model 5824 Specifications Serial /Parallel Interface (for printing system reports), and the 5895XL Primary AC: 120 VRMS at 50 / 60j Intelligent Power Module. The hz, 2.5A Model 5820XL also features a Total Accessory Load: 5A at 24 powerful built -in dual line fire VDC communicator that allows for 5 amps at 24 VDC of power - limited reporting of all system activity to a notification power location. Weight: 28 lbs. (12.8 kg) remote monitoring Standby Current: 140 mA Color: Red Features Alarm Current: 260 mA Telephone Requirements: • Up to 381 addressable points. Flexput C FCC Part 15 and Part 68 approved • Supports Class B (Style 4) and Six programmable circuits which Type of Jack: RJ31X (two required) Class A (Style 6) configuration can be programmed individually as: for SLC, SBUS, and Flexput Approvals: circuits. Notification circuits: 3 amps of UL Listing • Distributed, intelligent power. power limited power per circuit at NFPA 72 - Central Station • Drift compensation. 24 VDC. - Remote Signalling • Flexput TM I/O circuits. Auxiliary p ower circuits: 3 amps -Local Protective • Eight pre - programmed output • power - limited power per circuit at Signalling System 24 VDC. -Auxiliary Protected cadences, (including ANSI - 3.41), rY and 4 programmable outputs. Initiation Circuits: 100 mA of Premises Unit • Built -in annunciator with 80- power limited power per circuits at CFSM: 7165 -0559: 130 character LCD display. 24 VDC. • RS-485 bus provides communi- Mechanical Specifications: SILENT cation to system accessories. Dimensions: 16 "W x 26.4 "H x KNIGHT • Built -in RS -232 interface for 4.65 "D (40.6 x 67 x 11.8 cm) INTELLIKNIGHT FIRE ALARM CONTROL PANEL - IntelliKnight Model 5820XL Addressable Fire Alarm 2 Control Panel Indicator Lights' amp hours. An additional cabinet capability, download phone number GENERAL ALARM (Red) On for enclosure is required for batteries capability and touchtone or rotary in excess of 17 amp hours. dialing. The communicator is alarm compatible with SIA and Ademco TM SUPERVISORY (Yellow) - On Flexput circuits on the Model when a supervisory condition 5820XL control can be individually Contact ID. The format is exists. programmed to function as notifi selectable by account number. SYSTEM TROUBLE (Yellow) On cation circuits, auxiliary power User Interface when a trouble condition exists. outputs, or initiation circuits that The IntelliKnight's built -in support both 2- and 4 -wire smoke annunciator with 80 character LCD SYSTEM SILENCED (Yellow) - On detectors. display and large easy -to -use when an alarm, trouble or supervisory condition has been The IntelliKnight system operates tactile touchpad can be used for silenced but not yet cleared. on non - twisted, unshielded cable system operation, programming SYSTEM POWER (Green) On when wired in compliance with and maintenance. It has five LEDs standard wiring practices as called for alarm, supervisory, system when power systems are out in the National Electric Code trouble, system silenced and normal;flashes for AC or DC 760 specifications for power - limited system power. System operations failure. fire protective signalling cables. No include silencing alarms and System Application special wiring is required. troubles, resetting alarms and the The IntelliKnight Model 5820XL The Model 5820XL provides seven display of alarm troubles and control panel has one built -in preset notification cadence patterns memory. The system's non - volatile Signalling Line Circuit (SLC) which including ANSI 3.41 and four user event history buffer stores 1000 supports 127 devices. Two programmable selections for fire additional loops can be added alarm notification. using the 5815XL SLC expanders Two programmable general [ ;,,;, to increase overall capacity to 381 purpose Form C relay outputs are "° ••°° devices. provided on the Model 5820XL - ; ` The Model 5820XL's SLC loops FACP. iiimi 110 IN a A. support multiple device types. pp p yp Additionally, the IntelliKnight limn ma as at i • Addressable photoelectric smoke system features a built -in walk test En IN at II detector and auto - programming. Its , • Addressable ionization smoke innovative, dead -front cabinet detector design allows for flush or surface • Addressable heat sensor mounting. System maintenance is events for viewing from the built -in • Addressable duct smoke easy to perform. or remote annunciator. System detector Built -In Digital Communicator operation can be initiated with a • Contact module The IntelliKnight Model 5820XL mechanical firefighter's key or a • Relay output module features a built -in UL listed digital valid 4 to 7-digit operator's code. • Addressable notification module communicator for remote reporting Programming The following advanced sensor of system activity and system The IntelliKnight system offers capabilities are available using the programming. The communicator several options to simplify and IntelliKnight Model 5820XL: has the ability to seize two speed up programming. The • Automatic drift compensation telephone lines to report alarms JumpStartTM feature minimizes • Maintenance alert and troubles to a monitoring facility. programming required to start a The communicator supervises two new system. The built -in keypad • Built -in sensor test to comply phone lines and will activate a and the 5860 Remote Annunciator with NFPA 72 calibration testing trouble signal if a line failure is give on -site access to all requirements sustained for more than 45 programming. You can also The IntelliKnight 5820XL features a seconds. Other communication power supply and maximum program remotely using the 5 amp P pp Y features include: retry if communi- TM battery charging capacity of 33 cation fails, two phone number Windows Download Software. INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Intel Knight 5820XL Aderessable re Alirm S‘ Stem „ . .4 $1•41.. Men. M at • ea itt4 , sio,) us 6 6 Flexput Fiexput e HI .4 1 I * MM. A r SO %AM 14$66•444 5 4.ftr 137 . , ....• 5=44-1,111 4 SD:034MM 20401141114 SOW% 4171 :4U JJ 4111M 0) I 7 I Oft MO • • M , 411111.11111 118110441* /1060 $06$.44,00* SOWS* $004 4001 6011111441 MMOMMI ^ ■■ • MamM fr tan eooKt • ..1k 11111114 8111164 thv rot N* armies vl. 4 l e I NO *Or volvolvar Ilkokto V INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight System Accessories mount on a 4 inch square electrical 5860 Remote Fire box. Provides indicator LED to show output status and comes with a Annunciator coverplate. The 5860 features the i 4 Model SD500 -ANM same 80 character . - backlit LCD display Addressable Notification Module keypad and firefighter's providing a single Class A or Class B keyswitch as the 5820. The system can 0 notification circuit on the SLC. be fully programmed and operated Model SD505 -ADH from any remote annunciator. Duct Housing. Detects smoke in HVAC 5815X1 Signal Line Circuit Expander ducts. The SLC expander is used to add more w. " Model SD505 -ADHR addressable devices to the IntelliKnight 'm _ Duct detector base with relay. Provides system. The 5820XL can support two form C alarm contact. For use with 5815XLs. Each 5815XL can support Compatible Devices SD505 -APS and AIS sensors. 127 devices. IntelliKnight's devices feature a low Compatible with SD505 -DTS remote 5895X1 Intelligent Power Module test switch profile design and EEprom addressing. Adds 5 amps of power, 6 FlexputTM I/O EEprom addressing prevents water Model SD505 -DTS circuits and 2 Form C relay circuits to intrusion problems via the back of the Remote test switch. Used with SD505- an IntelliKnight system. sensor and eliminates mechanical ADHR. Provides remote key operated 5880 LED /I0 Module failures related to decade switches. test function and annunciation of Features 40 LED outputs, 8 normally Model SD505 -APS detector alarm. open dry contact inputs and one piezo Addressable photoelectric smoke Model SD505 -6SB output detector. Six -inch sounder base. Operates in 5865 -3 and 5865 -4 Model SD505 -AIS single and multi- station modes and /or Remote LED Annunciator Addressable ionization smoke detector. as a system sounder. Used with Features 30 Programmable LEDs (15 Model SD505 -AHS existing sensor and base. Requires 2 red and 15 yellow) outputs and piezo additional wires for power. sounder. The 5865-4 adds a silence Addressable heat sensor. Model SD505 -616 Model SD505 -6AB and reset switch to the package. Six -inch isolator base. Used with 5883 Relay Board Six inch base designed for use with existing base and the SD505 -APS, detector head models SD505 -APS, AIS, and AHS sensors. Provides Features 10 General purpose Form C SD505 -AIS and SD505 -AHS. isolation for style 7 circuits. relays. Used with 5880 module. Model SD505 -4AB Model SD505 -6RB 5824 Serial /Parallel Gateway Four inch base designed for use with Six -inch relay base. Used with existing Module detector head models SD505 -APS, sensor and base. Provides one Form C Has one parallel and one RS -232 serial SD505 -AIS and SD505 -AHS. contact. port for connecting any standard IBM - Model SD500 -AIM Model SD500 -SDM compatible printer to the IntelliKnight Dry Contact Input Module. Designed to Two -wire detector input module. Allows system. Interfaces with building control used with normally open dry contacts. for the connection of conventional 2- system. Mounts in a 4 inch square electrical wire detectors on the SLC loop. SI(SS Silent Knight Software Suite box. It features an indicator LED to Requires two additional wires for 5660 Up Down Load Software show alarm status and a coverplate. power. Model SD500 -MIM Model SDS00 -LIM User- friendly, WindowsTM software for remote programming of the IntelliKnight Mini Dry Contact Input Module. A Loop Isolator Module. Provides panel using a PC. miniature version of the addressable isolation for style 7 circuits. input module which is designed to be 5670 Facility Management Software used with pull stations and other Model SD500 -PS Powerful end -user software allows normally open dry contact inputs where Addressable Pull Station viewing of detector status and event a smaller size is desired. S -BUS Accessories history via modem or direct connection. Model SD500 -ARM The following items listed are devices Addressable Relay Module. Features 2 that connected to the IntelliKnight's RS- Form C output relays, designed to 485 Bus 410 SILENT KNIGHT MADE IN AMERICA . FORM# 350210, Rev, 09/00 7550 Meridian Circle, Maple Grove, MN 55369 -4927 Copyright © 2000 Silent Knight 800 - 446 -6444 or in Minnesota 612 - 493 -6435 FAX: 612- 493 -6475 IntelliKnight is a Registered Trademark of Silent Knight World Wide Web: http: / /www.silentknight.com Flexput is a Trademark of Silent Knight INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy -to -use interface found on the IntelliKnight panel's built -in annunciator. The 80- character display and ergonomically designed keypad allow for simple and error -free system operation. All operations — including reset, silence, detector status checking, fire drill, and programming —are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS -485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 - 446 -6444, or in Minnesota, call 763- 493 -6435. Description • Available in red or light gray Features include an 80- character • Support for simultaneous use of backlit LCD providing easy -to- multiple 5860s understand system messages. The • RS -485 interface to panel annunciator is ergonomically • Operation and appearance is designed with over -sized buttons identical to 5860 built -in II ri ' Ut for the most frequently used annunciator uw 4 features, like Reset and Silence. • On -board piezo sounder audibly = OLIO ti In addition to status messages indicates alarms, troubles, and 41* 04 e displayed on the LCD, there are Fiv st ies five LEDs for alarm, supervisory, • Five status LEDs for alarm, supervisory, trouble, silence and trouble, silence, and AC power AC power conditions 5860 status. • Wiring lengths up to 6000 ft. from The annunciator is available in gray the FACP (depending on wire Color to match virtually any decor and gauge and number of devices on 5680R: Red red for applications where the SBUS) 5680: Gray • UL listed, complies with NFPA 72 annunciator must stand out. The Environmental • annunciator enclosure can be CSFM approved Operating Temperature: 32 °F – surface or flush mounted. A trim Electrical Specifications 120 °F (0 °C – 49 °C) ring kit is available for surface Operating Voltage: 24 VDC Humidity: 10% – 93% non - mounting. Standby Current: 20 mA max condensing Features Alarm Current: 25 mA Approvals • 80- character backlit LCD display Wiring Distance: 6,000 max. from NFPA 72; UL Listed; (4 lines with 20 characters on FACP (depending on wire gauge CSFM 7170 -0559: 135; each line) and number of devices on the MEA 429 -92 -E Vol. IX; • Tactile and audible feedback SBUS) FM Approved • Accepts user codes or fire fighter's key Max Per System: 8 • Larger keypad buttons for system Mechanical Specifications SILENT reset and silence Physical 9.1" W x 7.4" H x 1.5" D KNIGHT • Install up to eight 5860s per (23.1 W x 18.8 H x 3.8 D cm) FACP by Honeywell Shipping Weight: 2.8 lbs (1.3 kg) INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator Engineering Specifications The main control must have a built -in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built -in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built -in annunciator. All annunciators must have an 80- character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP '. 111111111 .. MIN SBUS rat ,7,1: 41e, • VR1I:.ik �y "`" 644 0 : t N M 5860 5860 5860 Up to Eight 5860s Per System Compatible IntelliKnight FACP Compatibility Ordering Information Accessories IntelliKnight 5820XL FACP 5680R Remote Annunciator 5860TR Red Trim Ring IntelliKnight 5808 FACP Four line LCD annunciator with 20 For surface mounting. characters per line. Red. IntelliKnight 5700 FACP 5860TG Gray Trim Ring 5680 Remote Annunciator. For surface mounting. Four line LCD annunciator with 20 characters per line. Gray. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA N KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350224 Rev C, 05/06 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, MN 55369 -4927. Copyright © 2006 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. INTELLIKNIGHT ACCESSORY Model SD500 -ARM , ° Addressable Relay Module d -` :.1:11 - r-,4, 1 , , .::.„,,.., A p:•,; �.,.' Place relay applications anywhere on the ,,,,, ".n IntelliKnight loop with the SD500 -ARM ,.. ; V Addressable Relay Module. The SD500 -ARM is an addressable device that adds great flexibility to the IntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp © 120 VAC. The SD500 -ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other IntelliKnight SLC devices, the SD500 -ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices —easy installation and stable operation —and it adds up to a flexible solution for all your fire protection needs. Model SD500 -ARM Features Addressable Relay Module j r...1 . • Two sets of Form C contacts. . 1() , • The SD500 - ARM provides two Contacts are rated at 2A @ 30 © e �6 Form C contacts rated at 2A @ VDC or .6A @ 120 VAC. 30 VDC or .6A @ 120 VAC. • Up to 127 relays can be used on each SLC loop. These contacts can be used for V O 1%; virtually any normally open or • Relay programming is r normally closed application. completely flexible — can be Model SD500 - ARM mapped to zone conditions. • Polling LED visible through Specifications Operation cover plate. • UL listed, complies with NFPA Contact Rating: Form C Each relay module is 72. 2A @ 30 VDC programmed with a unique SLC • CSFM approved 6A @ 120 VAC loop address. When an event • MEA Approved, 429 -92 -E, Vol. 9 that controls the relay module . FM approved Standby Current: .55 mA . occurs, the relay is triggered by the IntelliKnight panel. Alarm Current 55 mA Ambient 32 °F to 120 °F Temperature (0 °C to 49 °C) It SILENT Mounting 4- square electrical box KNIGHT INTELLIKNIGHT ACCESSORY Model SD500 -ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500 -ARM. The modules shall be UL listed compatible with Silent Knight's Intelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4- square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW 0 O COI:: ,JAI 0 \ .I x ECM C :l o a C,Ix 0 N ► 4 -718" 4 " N� 1 Model SD500 -ARM Addressable Relay Module Dimensions SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 -446 -6444 or in Minnesota 763 - 493 -6435 FORM# 350218, Rev. 11/01 FAX: 763 - 493 -6475 World Wide Web: http: / /www.silentknight.com Copyright © 2001 Silent Knight FIRE SYSTEM ACCESSORY Firepower 5496 ... - , .. i Distributed Power Module i l ,. ' � ,01 F ' ` A dynamic combination of power and intelligence ,�' .' for your notification expansion needs. The Model 5496 Intelligent Power Module by Silent Knight is the most - ``* " " powerful and cost - effective power supply available today. It delivers 6 amps of -Y '' ` q notification appliance circuit power and built -in synchronization for appliances from Gentex®, Faraday, AMSECO and Wheelock® — what you need to drive power -hungry components like ADA notification appliances. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. For the most sophisticated and cost - effective notification power supply available, you need Firepower 5496. Call Silent Knight today for more information at 1- 800 - 446 -6444. Model 5496 • 3 amps per output circuit Intelligent Power Module • Ground fault detector g • Communicates to the FACP via 4- The model 5496 is a 6 amp notification wire SBUS (wire runs up to 6000 ft) power expander that provides its own • AC loss delay option shuts off power AC power connection, battery charging to non - essential high- current circuit, and backup battery for use with accessories like magnetic door fire and security controls such as the holders IntelliKnight Model 5808 Fire Control • Lightweight design adds to ease of /Communicator. The 5496 is the cost- ) installation and reduces shipping effective solution for powering costs notification appliances required by the UL 864 & 1481 listed • Americans with Disabilities Act (ADA). The 5496 has built -in ANSI cadence • CSFM approved pattern, which can upgrade older • ANSI Cadence pattern output control panels that lack cadence capability built -in capability. The Output circuits can be Specifications programmed as Notification Appliance AC Input 120 VAC at 2.7 A �' . Circuits, or as Auxiliary Power (configurable for, constant, resettable, Output: 24 VDC at 6 amps Model 5496 Intelligent or door holder power). Current: Power Module Features Standby 40 mA Battery charging • UL Listed for 6 amps of notification Alarm 160 mA capacity: 33.0 AH power Notification /Aux. Ambient Temp.: 32° to 120° F • Power supply's advanced switch Power circuits: 4 0° to 49° C mode design reduces damaging Output Dimensions: 12.25" W x 16" H x heat and manages power up to 50% configuration: 2 Class A (Style Z) 3" D (30.88 cm W more efficiently than other systems 4 Class B (Style Y) x 40.64 cm H x • Built -in synchronization for (1 Class A & 7.62 D cm) appliances from AMSECO, Gentex, 2 Class B) Faraday, and Wheelock® Amps per Approvals: UL • 24 VDC filtered output voltage output circuit: 3.0 (6.0 amps total) NFPA 72 . • Four power - limited notification Notification outputs; 2 Class A or 4 Class B, or 1 circuit output: 20.4 to 27.3 VDC Class A and 2 Class B @ 3.0 amps each, • NACs are programmable as 4 kO EOL SILENT Notification Appliance Circuits, or as on resistor required B auxiliary on each Class B itp KNIGHT ry power to be used as circuit constant, resettable, or door holder h , power FIRE SYSTEM ACCESSORY Firepower 5496 Distributed Power Module Engineering Specifications The contractor shall supply a power module compatible with the Silent Knight FACP. The power module must have 6.0 amps of output power. The power module shall connect to the main FACP via an RS 485 system bus (SBUS). The Outputs shall be programmable as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power). The power module shall have four separate outputs. The power module RS 485 bus shall be optically isolated providing ground loop isolation and transient protection. 4 outputs programmable as Notification Appliance Circuits, or as Auxiliary Power Output 1 . SBUS Communication to a compatible Output 2. Silent Knight FACP Output 3 ". Output 4 Li W Auxiliary power can be programmed to be, constant, resettable, or door holder power Compatible FACPs IntelliKnight 5808 IntelliKnight 5820XL i t SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 -446 -6444 or in Minnesota 763 -493 -6435 FORM# 350387, Rev. 04/02 FAX: 763 -493 -6475 Copyright © Silent Knight World Wide Web: http: / /www.silentknight.com INTELLIKNIGHT ACCESSORY Model SD500 -AIM Addressable Input Module ) And eto illt / Model SD500 -MIM Miniature Input Module y rF",k IntelliKnight's addressable contact monitor modules combine fast response with pin -point location ID. A combination that saves lives and property. The SD500 -AIM and SD500 -MIM are addressable input modules for use with Silent Knight's IntelliKnight fire control panel. The SD500 -AIM and SD500 -MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500 -AIM addressable input module mounts to a 4 "- square box. The SD500 -MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500 -AIM and SD500 -MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation —a flexible solution for all your fire protection needs. Model SD500 -AIM and SDS00 -MIM Input Modules The addressable input modules expand the flexibility of the IntelliKnight system by allowing the use of contact type inputs. Typical = E , applications include manual pull stations and water flow switches. Features • Operates on Class A (Style 6 & Style I ~ 7) or Class B (Style 4)SLC Loop. • Single contact monitor. SD500 - AIM SD500 - MIM • Up to 127 modules per SLC loop. • SD500 -MIM mounts in a single gang Operation Specifications box. Each addressable input module is Operating Voltage 24 VDC • SD500 -AIM mounts in a programmed with a unique SLC Standby Current: 0.55 mA 4 "- square or double gang electrical loop address. The module Alarm Current: 0.55 mA box, and has an attractive ivory supervises the wiring to the contact cover plate. with an End Of Line (EOL) resistor. Ambient Temperature: 32 °F to 120 °F • SD500- AIM /MIM are DIP switch If a fault occurs in the wiring, the (0°C to 49 °C) programmable. module alerts the FACP. Mounting: SD500 -AIM • Accepts up to 14 gauge wire. double gang box or • Both modules UL 864 listed; comply b " - square electrical p y box with NFPA 72 • 2500 ft max. wiring distance from S ngle ga g input module to contact single gang box • CSFM listed. • MEA 429 -92 -E, Vol. 9 SILENT • FM approved ` KNIGHT 1 INTELLIKNIGHT ACCESSORY Model SD500 -AIM and SD500 -MIM Addressable Input and Mini Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500 -AIM or SD500 -MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500 -MIM shall fit inside a single gang electrical box. The SD500 -AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4 "- square or double gang electrical box. The SD500 -AIM addressable input module must provide a monitor LED that is visible from outside the cover plate. Model SD500 -AIM FRONT VIEW BACK VIEW SIDE VIEW • 0 o IA A IAA O I:03 �._.....- ..m. i l • 1± 4 -7/8" 4. Model SD500 a - _ 0 °` ■ M/Z ° Iik rAININl • 11116 i t SILENT h KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800- 446 -6444 or in Minnesota 763 - 493 -6435 FORM# 350231, Rev. 11/01 FAX: 763 - 493 -6475 World Wide Web: http: / /www.silentknight corn Copyright © 2001 Silent Knight INTELLIKNIGHT ACCESSORY Model SD500 -ANM Addressable Notification / - Module A 3 ' (fly The cost effective way to expand the , 0 ay. IntelliKnight's notification circuits. The SD500 -ANM gives you the flexibility to add notification circuits wherever you need them. The SD500 -ANM is a supervised addressable notification device that provides you with additional notification circuits on the IntelliKnight SLC loop. Up to 127 SD500 -ANM modules can be used on an SLC loop. The SD500 -ANM provides a reverse polarity Class A or Class B notification appliance circuit with an aux power input. Each SD500 -ANM is provided power from a separate power supply and is controlled and supervised by the main panel. Power can be provided near the signaling appliance to reduce the wire gauge requirements or can come from a main power supply and be controlled separately by the individual notification modules. The SD500 -ANM can produce all 16 of the notification patterns available on the FACP. Model SD500 -ANM Features Specifications Addressable Notification • Class A (Style Z) or Class B Operating Voltage: 24 VDC Module (Style Y) Notification Circuit. SLC current: .55 mA The SD500 -ANM is an Addressable • Flexible programming— choose Aux. Power Current: Notification Module for use with the the cadence pattern (twelve Alarm: 56 mA IntelliKnight fire alarm control standard & four user - defined). Standby: 6 mA panel. The SD500 -ANM provides a • Polling LED visible through cover Notification single class A or B circuit that is plate. Appliance Current: 2 Amp Max. controlled by the IntelliKnight's • UL listed, complies with NFPA Ambient Temperature: 32 °F to 120 °F Signaling Line Circuit. Power for 72 (0 °C to 49 °C) the circuit is provided to the CSFM Approved. Mounting: 4- square • SD500 -ANM module from a electrical box. separate power supply, making it • MEA Approved 429 -92 -E, Vol. 9 Compatible Control Panel: 5820XL easy to power remote devices. • Adds up to 127 independent The notification circuit, remote output circuits on each SLC loop. power and communication to the • Supervised auxiliary power SD500 -ANM are supervised by the source input. IntelliKnight control panel. • Completely supervised. Operation Each notification module is programmed with a unique SLC. loop address. When an event that /F_ % controls the notification module occurs, the notification switches its built -in relay feeding power from the auxiliary power input to the`' th'° ` min notification appliance. SILENT 4 " by Honeywell Model SD500 -ANM INTELLIKNIGHT ACCESSORY Model SD500 -ANM • Addressable Notification Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable notification modules, Silent Knight SD500 -ANM. The modules shall be UL listed compatible with a Silent Knight IntelliKnight fire alarm control panel. The notification module must provide one Class A (Style Z) or Class B (Style Y) notification output with one auxiliary power input. The notification module must be suitable for mounting in a standard 4- square electrical box and must include a plastic cover plate. The notification module must provide an LED that is visible from the outside of the cover plate. The notification output must be fully programmable for such applications as are required by the installation. FRONT VIEW • ............... Rc_t1OV #. Pr ?. t 1a l st;<;: t, s 3 >; Lt I 4718" 1 § ) • .• tit A ! I 4-7/8" 114" 4 M 1 Model SD500 -ANM Addressable Notification Module Its SILENT KNIGHT by Honeywell MADE IN AMERICA 7550 Meridian Circle, Maple Grove, MN 55369 -4927 FORM# 350220, Rev. 02l04 800 - 446 -6444 or in Minnesota 763 - 493 -6435 Copyright © 2004 Silent Knight FAX: 763 - 493 -6475 World Wide Web: http: / /www.silentknight.com IntelliKnighte is a registered trademark of Silent Knight INTELLIKNIGHT ACCESSORY Addressable Photoelectric Type . Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505 -APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505 -APS compensates automatically for contamination in the environment. And detector testing is simple —even from a remote site. Like other IntelliKnight detector models, the SD505 -APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 -APS The light received is converted into Analog / Addressable an electronic signal. Under normal 9 ressa conditions, the status LED blinks Photoelectric Type approximately every 15 seconds, / Smoke Detector indicating that the head is a The SD505-APS is particularly communicating with the loop. The LED lights continuously during the suited to detecting dense smoke alarm period. typical of fires involving materials such as soft furnishings, plastic, Features foam or other similar materials • Low profile, 2 inches, including SD505 -APS Smoke Detector which tend to smolder and produce base Specifications large visible particles. • Simple and reliable addressing Operating Voltage: 17 -41 VDC The detector features automatic without mechanical switches Current Consumption: compensation for contamination • Automatic compensation for Standby: 55 mA and a simple detector calibration sensor contamination Alarm: .55 mA test procedure that can be run from • Built -in fire test feature ° the panel or remotely (using the • Simple detector calibration Ambient Temperature: ( 0 °c to 50°C) WindowsTM based downloading testing through the control panel software). Mounting: 4" Square, 4" OCT, or remotely through a Single gang mud Operation WindowsTM based computer ring The SD505 -APS units made up of software. Relative Humidity 85% an LED light source and a silicon • Vandal- resistance locking noncondensing photo diode receiving element. In a features Air Velocity: 0 - 300 FPM • Field cleanable normal standby condition, the Compatible Bases: SD505 -6A8 receiving element receives no light • UL listed, meets NFPA 72 Ch 7 (Sold Separately) (6" Base) from the pulsing light source. In the requirements SD505 -4AB event or fire, smoke enters the • CSFM approved (4" Base) detector and light is reflected from • MEA approved the smoke particles to the receiving • FM Approved SILENT element. KNIGHT INTELLIKNIGHT ACCESSORY Model SD505 -APS Addressable Photoelectric Type Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505 -APS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505 -AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505 -APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. I � Diameter = 5- 15/16" N Diameter = 3- 15/16" I4 N .<:-,, e % \ ,."re. lc ‘,),4.1 . - r* ,0- Height = 2 inches, including base lasialll -/ Model SD505 -6AB Detector Base Model SD505 -APS Detector Head (front view) (front view) i ti SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 -446 -6444 or in Minnesota 763 -493 -6435 FORM# 350225, Rev. 12/01 FAX: 763 - 493 -6475 Copyright ©2001 Silent Knight World Wide Web: http: / /www.silentknight.com INTELLIKNIGHT ACCESSORY . Addressable Heat Detector �_ ~� . ..,f,„,..,,,,„ ,,, 'q } IntelliKnight® addressable heat detectors combine lt accurate heat detection with pin -point location ID. � . �� An essential combination for any installation. IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other IntelliKnight detector models, the SD505 -AHS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 -AHS If the temperature exceeds the trip Addressable Heat Detector point (programmed at the panel) an alarm occurs. The status LED The SD505 -AHS is a heat detector lights continuously during the alarm �`f j \ suited to virtually any commercial period. ' < i setting. The SD505-AHS is an absolute temperature device. This Under normal conditions, the status means that it responds in alarm if LED blinks approximately every 15 the temperature goes above the seconds, indicating that the head is trip point (programmed at the communicating with the loop. panel). Features The SD505 -AHS provides accurate • Low profile. 2 inches, including SD505 -AHS Heat Detector temperature measurement data to base Specifications the fire alarm control panel. This Absolute temperature device Operating Voltage 17 to 41 VDC • heat detector is particularly suited to environments where smoke • Simple and reliable addressing Current Consumption: detectors cannot be used because • Uses digital communication Standby: 55 mA of the presence of steam or protocol Alarm 55 mA cooking fumes, such as in a • The SD505 -AHS is UL Listed Detection Temperature Range: 135 °F to 150 °F kitchen. and meets the requirements (57 °C TO 65 °C) Operation outlined in NFPA 72 Inspectio Ambient Temperature 32 °F to 100 °F The SD505-AHS unit is made up of Testing and Maintenance, (0 °C to 37 °C) Chapter 7. an externally mounted thermistor Mounting: 4" SQR, 4" OCT with a specially designed cover that • CFSM listed Single gang mud protects the thermistor while • MEA listed ring allowing maximum air flow. The F a roved Rated Spacing 70' between thermistor reads the temperature pp sensors on smooth ceilings . from the air it takes in. It then transmits a signal representing the Compatible Bases. SD505 -6AB temperature IntelliKnight SILENT (Sold Separately) (6" Base) tem to the p g KNIGHT (4" Base) � (4" Base) ) INTELLIKNIGHT ACCESSORY Model SD505 -AHS Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505 -AHS. The combination detector head, and twist -lock base, shall be U12 listed compatible with Silent Knight's IntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent SD505 -APS Photoelectric Smoke Detector, or SD505 -AIS Ionization Smoke Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF /transient suppression techniques shall be employed to minimize false alarm potential. Diameter = 5 - 15/16" N l' Diameter = 3 15/16" ,I •�" Height = 2 inches, including base « rr / Model SD505 -6AB Detector Base Model SD505 -AHS Detector Head (Front View) (Front View) tigi SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 -446 -6444 or in Minnesota 763- 493 -6435 FORM# 350229. Rev. 01/01 FAX: 763 - 493 -6475 Copyright ©2001 Silent Knight World Wide Web: http: / /www.silentknight.com INTELLIKNIGHT ACCESSORY SD500 -PS and SD500 -PSDA ; ,; Addressable Pull- Station a A ° '� „ IntelliKnight's addressable pull stations k4 ... combine fast response with pin -point .. � location ID. The SD500 -PS and SD500 -PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500 -PS /PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500 -PS /PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500 -PS & • Extremely easy to operate SD500 -PSDA • Corrosion - resistant gold - plated Addressable Pull • contacts. 4 • Reflective label makes it easier + Station to locate in low light The SD500 -PS is a single action Operation `' addressable fire pull station, and The SD500 -PS /PSDA single action a.,:.' \. the SD500 - -PSDA is a dual action pull stations are operated by a pull r s g :, li addressable fire pull station. The on the front pull cover of the SD500 -PS /PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable FIRE on back of the pull station allows module, is released as the pull interconnection of the pull station to station opens to initiate the alarm. ) the SLC of an IntelliKnight control Once operated, the cover hangs panel. The SD500 -PS /PSDA is down and pull can be seen up to 100 designed for indoor use in non- feet away. The ull station is reset 1 ARM explosive environments. The by returning the front cover to the normally open initiating point normal upright position and contacts are gold - plated to avoid relocking the station with a reset ti►tt.\ r risk of corrosion. The SD500- key. The reset keys are the same ! kmcii t. PS /PSDA has been tested by UL keys used on Silent Knight for compliance to the requirements enclosures. of the Americans with Disabilities The SD500 -PS /PSDA includes a ACT (ADA). status LED which blinks, indicating SD500 -PS . Features that the addressable module is Ambient Temperature: 32 °F to 120 °F • UL Listed communicating with the loop. The (0 °C to 49°C) • CSFM listed status LED lights continuously Mounting: Single gang during an alarm. A dip switch on box - • • ADA compliant Optional Red Surface Mount Box PS -SMBB the addressable module is used to • Key reset (Same key as Silent set the unique address. Knight enclosures) • Surface mount back box Specifications available Operating Voltage: 24VDC El SILENT Standby Current: .55mA KNIGHT • Terminals - accept up to 14 Alarm Current: .55mA gauge wire "` ,, , INTELLIKNIGHT ACCESSORY SD500 -PS and SD500 -PSDA F 7 T. Addressable Pull- Station Engineering Specifications Manual pull station shall be addressable Module SD500- PS /SD500 -PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. k rcP ( . `` , ti ., .... vita e. .i !?. „... Ic. t fil0 S. I `tte 1 > ` w �wr.www�rwwr ...... s r t ' r — Li, . v o w„� ”` 1 i,,: .Nt w,. ;,., ., + ,,, -..�^" • Ca SF wan. si ti t ��� ~i i. Wiring h i # 7 1 Mounting to Single Mounting to Optional Gang Electrical Box Surface Mount Box 4 , F t..t:rtr' t� 1:74A*46 I SD500 -PSDA .,. t ,.. I LIFT f 1 , F t EMtzrksi ffr . tmtrif 4:* Installing SD500 -LK Dimensions O. ` -' 1 Erg Ell SILENT KNIGHT A tstvotwa Ucax6ktW 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 - 446 -6444 or in Minnesota 763 - 493 -6435 FORM# 350342, Rev. 09/03 FAX: 763 - 493 -6475 Copyright ®2003 Silent Knight World Wide Web: http: / /www.silentknight.com GENTEX CORPORATION II Smarter Vision' Commander Series Selectable GEC3 /GES3 Candela Evacuation Signals 12 & 24 VDC Applications S E R I E S The Commander Series is a low profile strobe or horn /strobe combination that offers dependable audible and visual alarms and the lowest current available. The GE3 Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The 12VDC offers tamperproof field selectable ----•� candela options of 15, 30, 60, and 75 candela. 14, _ The Commander Series horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for 1 the professional to change in the field by using switches. The GE3 Series has a minimal operation current and has a minimum flash rate of 1Hz regardless of input voltage. Product Listings The Commander Series is shipped with the standard 4" mounting plate which incorporates the popular Super- Slide feature that allows the installer to easily test for supervision. The product also features a locking mechanism which Y 4> secures the product to the bracket without any screws showing. rA_: US lie APP ROVED syrtri or lm waawh norne,kAle nem. " The Commander also features the Checkmate - Instant Voltage Verification `•rawLwoERwRmeaswoR►y °RIEs, • feature which allows the installer to check the voltage drop draw and match it to BFP (City of Chicago) the blueprint. • BS +A /MEA #285 -91 -E • CSFM 7135 - 0569:122 (GEC3 -24 & GEH -24) 7125 - 0569:123 (GES3 -24) The GE3 Series appliances are UL 464 and UL 1971, listed for use with fire pro- 7125 - 0569:129 (GES3 -12) tective systems and are warranted for three years from date of purchase. 7135- 0569:130 (GEC3 -12 & GEH -12) Standard Features • FM Approved • UL 464 & UL 1971 Listed • Nominal Voltage 12 & 24 VDC • CAN /ULC S526 -M87 Listed • 24 VDC units have field selectable candela options of ULSZ7.S3406 Listed (GEC3-24, 15, 30, 60, 75, and 110 candela GEH24 & GEH12) • 12 VDC units have field selectable candela options of Product Compliance 15, 30, 60, and 75 candela • NFPA 72 • GEH horn is available in 12 or 24 Volt • Americans with Disabilities Act (ADA) • Super - Slide Bracket - Ease of Supervision Testing, • Checkmate - Instant Voltage Verification /°s • Unit Dimensions: 5" high x 4.5° wide x 2.5" deep � MEM ER • Synchronize Strobe and /or Horn with Gentex Series Control Module (12 Volt product must use the AVSM • Switch for Continuous or Temporal 3 (not available on Module) whoop tone) • Prewire Entire System, Then Install Your Signals • Surface Mount with the GSB (Gentex Surface • Lower Installation and Operating Costs Mount Box) • Input Terminals 12 to 18 AWG • Silence Horn While Strobes Remain Flashing • Switch Selection for High or Low dBA • Wide Voltage Range 8 -17.5 VDC (12 Volt Models) • Switch for Chime, Whoop, Mechanical and 2400Hz Tone 16 -33 VDC or FWR (24 Volt Models) • Tamperproof Re- entrant Grill • Faceplate Available in Red or Off -White GEH 12 or 24 Volt Low Profile Evacuation Horn Model Number Part Number - Nominal ' Reverberant dBA @ In Anechoic Room Voltage 10ft. Per UL 464 dBA @10ft. GEH12 -R 904 -1239 -002 ' 12 VDC 62 -82 100 GEH12 -W 904- 1241 -002 12 VDC 62 -82 100 GEH24 -R 904- 1205 -002 24 VDC 62 -82 100 GEH24 -W 904 - 1207 -002 24 VDC 62 -82 100 GES3 12 or 24 Volt Selectable Candela Low Profile Evacuation Strobe Model Number Part Number Nominal Candela Voltage (UL 1971) Model designations: GES3 -12WR 904 -1235 -002 12 VDC 15, 30, 60, 75 "W" = Wall Mount GES3 -12WW 904- 1237 -002 12 VDC 15, 30, 60, 75 "R" = Red Faceplate GES3 -12PWR 904 - 1236 -002 12 VDC 15, 30, 60, 75 "W" = Off-White Faceplate GES3 -12PWW 904 - 1238 -002 12 VDC 15, 30, 60, 75 "P" = Plain (no lettering) Available GES3 -24WR 904- 1321 -002 24 VDC 15, 30, 60, 75, 110 with all models. GES3 -24WW 904 - 1319 -002 24 VDC 15, 30, 60, 75, 110 These units are non - returnable. GES3 -24PWR 904 -1322 -002 24 VDC 15, 30, 60, 75, 110 "Agent" bezel also available. GES3 -24PWW 904 - 1320 -002 24 VDC 15, 30, 60, 75, 110 GEC3 12 or 24 Volt Selectable Candela Low Profile Evacuation Horn /Strobe Model Number Part Number Nominal - Candela Reverberant dBA @ In Anechoic Room Voltage (UL 1971) 10ft Per UL 4641 dBA @ 10ft. GEC3 -12WR 904 -1231 -002 12 VDC 15, 30, 60, 75 62 -82 100 GEC3 -12WW 904 - 1233 -002 12 VDC 15, 30, 60, 75 62 -82 100 GEC3 -12PWR 904 - 1232 -002 1 - 2 VDC 15, 30, 60, 75 62 -82 100 GEC3 -12PWW 904 - 1234 -002 12 VDC 15, 30, 60, 75 62 -82 100 GEC3 -24WR 904 - 1317 -002 24 VDC 15, 30, 60, 75, 110 62 -82 100 GEC3 -24WW 904 - 1315 -002 24 VDC 15, 30, 60, 75, 110 62 -82 100 GEC3 -24PWR ' 904- 1318 -002 24 VDC ' 15, 30, 60, 75, 110 62 -82 100 GLC3- 241-)WW 904 -1316 -002 24 VDC 15, 30, 60, 75, 110 62 -82 100 Notes: • The GE3 Series is not listed for outdoor use. • Operating temperature: 3210 120 °F (0° to 49° C). • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. 12 volt models are DC only. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014). GE3 -12 Product Strobe Current Ratings GE3 -24 Product Strobe Current Ratings Candela - 15cd 30cd 60cd 75cd Candela 15cd 30cd 60cd 75cd 110cd 12 VDC 106mA 131mA 186mA 237mA 24 VDC 55mA 63mA 88mA 112mA 136mA UL Max 1 63mA 212mA 331 mA 436mA UL Max 78mA ' 96mA 137mA 180mA 224mA GE3 -12 Product Horn Current Ratings GE3 -24 Product Horn Current Ratings Horn Mode ' Minimum Minimum Regulated Horn Mode Minimum Minimum Regulated dBA @ 10ft. dBA (4 10ft. 12VDC Max. dBA 4 10ft. dBA @ 10ft. 24VDC Max. per UL464 per UL464 Operating 4, per UL464 per UL464 Operating (HIGH) (LOW) High Setting (mA) (HIGH) (LOW) High Setting (mA) temp 3 2400Hz 76 69` 29 temp 3 2400Hz 78 71' 28 temp 3 Mechanical 75 68° 26 lemp 3 Mechanical 76 70* 25 temp 3 Chime 62* 60' 13 Temp 3 Chime 70 66' 15 Continuous 2400Hz 79 74' 29 Continuous 2400Hz 81 74' 28 Continuous Mechanical 78 72° 26 Continuous Mechanical 80 72' 25 on inuous ime 63 • Continuous Chime 70° 66' 15 Whoop 78 71' 55 Whoop 82 69° 56 'Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required for public mode fire protection service. These set- tings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. To obtain the horn /strobe current draw, add the strobe current draw and the horn current draw. r The listed reverberant dBA are for the Continuous Tone mode. The Temporal 3 Tone has a reverberant dBA (4 10ft. per UL 464 is 77 -83 with a horn current draw of 34mA. 2 HMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16 -33VDC for 24VDC units) (8 -17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. . Mounting Super-SlideTM Switch Locations SWITCH POSITION r- 1 3 4 5 ^+�J �'. � Mecnenlcal e conl. Temp ON ON ON �.' Me OFF ON ON � � fJ Hi. OFF ON OFF OFF ON ON Q ``� 111 1 Chime. Temp ON ON OFF 1 N C -Cont OFF ON OFF ! f' ;; P It t 1 I wh oop O OFF OFF �` _ =� �i, f whoop OFF OFF OFF i ; Switch Position 6 Al! �� I ��l II 1 f Ci 1 , ON > HIGH dB y 1rIII Ilk . a ! � �1] l OFF> LOW dB i ll1�'��' l 4 - "� Switch positions 1 and 2 % Illit t� -l � In the off position to select � - , r� !� I � � t(` isolated lwrn and strobe _, �U ► r Power inputs. R ,-- Die Cast Metal Mounting Plate: Mounts to single gang, - 't ER ER R R R double gang 4" square boxes or GSB box. \ —_ — . ON i r checkmate- - Instant Voltage Verification .44 ,f' 1 2 3 4 5 6 PP - 1 � N I L t s.4 Candela Selection Al s+ ! t . i s+ 17 I ■� 1 ''7.. Candela selection slider fir 4i ttl r watch Depress center 11 and slide switch to desired l _ bnghtn.St level �� ril 111 111. " ..- v or li The access holes are provided in the back of the terminal Break off pm and inseninto - hole at the bottom of the block to allow the voltage to be measured directly without selector to lock candela selling kli 1 ' Il removing the device. Typically this would be done at the Si9nal must be removed from bracket and pen pushed forward \ yyl 1 — 141 11 Ili l end of the line to confirm design criteria. Most measure- from t change candela. backside out of hole 1, j •- jiilll ments will be taken using the S+ and S- locations ' �� although access is provided to other locations. NOTE: J Care should be taken to not short the test probes. r � � Conventional GES3 /GEC3 Series Wiring Diagrams UL Listed UL Listed Control Control Panel Signal Signal panel S+ S+ S- H+ H- S+ S+ S- H+ H- 50 s. S- He H- Supervised �` ► o L 8 L Supervised 9 S B BI . c :. B S "" Signal CCiircuit / „ signal C „I" --71 ERE STORE o 111, . 1 A 11111 III11 T INE - ia \ ENO Or LINE RESISTOR 0 GEC3 /GES ''�, 12 VDCI. SERIEI: Wiring Diagram GE3 Series with Gentex Synchronization Module F.AC. P L ` eq , TO NE XT SIGNAL TO NOTIFICATION ALARM CIRCl/1T I TO NIXT SIGNAL 111111111111MM TO NOTIMCATION ALARM CIRCUIT REMOVE JUMPER -•M FORINDEPENDENT 800600 SYNCHRONIZED STROBE AUDIBLE SIGNAL ®+ : +~ v�E.ms FOLR r AND HORN OPERATION SYNCHRONIZAT CIRCUIT � aNL LEAVE JUMPER IN PLACE m _ r a TO ELIMINATE NEED FOR MODULE LEAVE JUMPER IN PLACE ON • 0 m - HORN INPUT ON AVSM AN UNITS UNLESS ARATE D RATE CONTROL OVER HORN SEP CKT \ IN OPE UNISON MODE SIGNAL B mm Z` L T $LAVE IS REQUIRED. SYNCHRONIZATION MODULE Signal Signal S. S. S- HO FE 50 S. 5- He H- 002002: Is 1 G G GI Ia s s m el VISIBLE SIGNAL 0 r I d __• y RESISioR FOR CIRCUIT I class e �- I r .� - -- --# YIxINO dMIY I I � 1 1 •} � I ■ RE ND CF LINE f`C,,�/[_�J� x-1-1 - WIR ONLY ( (/�• . - -. -I . Note: See Technical Bulletin 015 for proper synchronization module for application. Note: When synchronizing the GE3 12 VDC Series, the AVSM synchronization module MUST be used. Architect & Engineering Specifications: The audible and /or visible signal shall be Gentex GE3 Series or approved equal and shall be listed by Underwriters Laboratories Inc. per UL 1971 and /or UL 464. The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible /visible) shall produce a peak sound output of 100dBA or greater at 12 or 24V as measured in an ane- choic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the abil- ity to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible /visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 55mA or less at 24 VDC for the 15Cd strobe circuit and 106mA or less at 12 VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with termi- nals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16 -33 volts with either direct current of full wave rectified power for 24 volt models or a voltage range of 8-17.5 volts for 12 volt models. The appliance shall be capable of testing supervision without disconnecting wires. Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. 24 units per carton 28 pounds per carton Important Notice: G E N T E X These materials have been prepared by Gentex Corporation ('Gentex for Informational purposes only are 551-0050-02 necessarily summary. and are not purported to serve as legal advice and should not be used as such Gentex makes no representations and warranties, express or implied, that these materials urn complete CORPORATION end accurate, up-to -date, or in compliance with all relevant local, state and federal laws. regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainly regarding inlerprelatlon of laws, regulations and rules and the application of such laws, regulations and rules to poetic' Fire Protection Products: www.gentex. com utar tact pa erns. Each person's activieas can dillerenlye act the obi gabone that exist under appl able laws, regulations or rules. Therefore, these materials should be used only for informational purposes and 10985 Chicago Drive Box 310 • Zeeland, Michigan 49464 should not be used as a substitute for seeking professional legal advice. Gentex will not he responsible for 616.392.7195 • 1.800.436.8391 • 616.392,4219 Fax any action or laewe to act In reliance upon the informntiun wntamad In this material. Gentex corporation reserves the nylrt to make changes to uIC pluduct data sheets .,t lllelr dlscrrna,r € o Rioted on Regckd Paper GENTEX GX911GX93 12 or 24 VDC Low Current Mini -horn SERIES Temporal (GX93) or Continuous (GX91) tone with Terminal Blocks Applications The GX91/GX93 Series mini -horn is a select either the continuous tone or the high quality remote signaling appliance that temporal 3 evacuation tone. offers dependable remote annunciation. The GX93 can be used on the same sync The GX91/GX93 is listed for use with circuit (AVS44) as other Gentex signals both filtered and unfiltered power. such as the Commander series. The GX91 is a continuous tone mini horn. The GX91 /GX93 appliances are UL 464 This unit is not synchable with the AVS44 listed for use with fire protective systems control module. It is however synchable and are warranted for three years from the from the panel. date of purchase. With the GX93 a jumper is provided to GX91 /GX93 Remote Audible Signal Standard Features • Single Unit is capable of 12 or 24 • To Synchronize the GX93 use the Approvals VDC determined by the input voltage Gentex AVS44 Control Module • Selectable Temporal 3 or Continuous • UL 464 Listed for Fire Protective Service Tone on the GX93 (Jumper Pin) • Textured Finish High Impact Plastic • GX91has a Continuous Tone horn only Faceplate, Available in Fire Alarm Red Ijl • Horn Frequency is 3100Hz or Off -White UMW L �% LIMMA19111 M. R • Terminal Blocks (12 AWG to 18 AWG) • BFP (City of Chicago) • Low Current Consumption • BS +AIMEA #285-91-E-XVI • Variety of Mounting Options for New • CSFM Listing 7135 - 0569:126 • Construction and Retrofit Applications UL 464 Available Models Horn In Anechoic In UL Reverberant Model Part Input Current Room dBA Room Per Number Number Voltage Range (mean DC) @10Ft. UL 464 @ 24 VDC GX91R 904 -1274 8 -33 v 4 -17mA 90 85 dBA GX91W 904 -1275 8 -33 v 4 -17mA 90 85 dBA GX93R 904 -1276 8 -33 v 5 -25mA 90 81* dBA GX93W 904 -1277 8 -33 v 5 -25mA 90 81* dBA Input Voltage Range: 8 -33 VDC OR VFWR Operating temperature Indoor: 32° to 120 °F 0° to 49'C GX91 Average Horn Current is 15mA @24VDC GX93 Average Horn Current is 22mA @24VDC * The sound output for the Temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the Temporal 3 mode its sound pressure is the same as the continuous mode. "R" = Red faceplate 'W' = Off -White faceplate • GENTEX GX911GX93 Dimensions SERIES Mounting 4.711 21:4 4.70 17621 I ILI ----:j 0 1 IUTY_4 I liO C.) OP O — 14 1 / i f + IA LL (ILA 13X . CnInRaL DEL i P i + SUPERVISED I I END OF LINE CD :LIT �sys roe ca.rr I / \ 0 R® + . RED / RED Rm BLACK RIAD( 1 1 a Wiring Diagram t ..` WTI. Noriiiiime xmG AaRiMPORDLA S I060/rIINRFiAMIXlAL104 OOMIIOLY CDELJ r•r qy SGP -R SGP -W "`°" ,� r „ r, •, �, Trim Plate for GX91 /GX93 CI.. III PM id aniiimilmall'IN MIA II Architect & Engineering Specifications The alarm horns shall be Gentex Model •� till l GX911GX93. The appliance shall be listed with MINN .a. Underwriters Laboratories for use with Fire Protective Signaling Systems and produce a peak sound output of 90dBA or greater as 24 units per carton measured in an anechoic chamber. The 6 pounds per carton appliance shall be of solid -state construction and be polarized to operate from 8 -33 VDC with a 15 milliamp drain GENTEX the GX91 and 22 milliamp current drain on the GX93 at 24 VDC. The appliance shall be provided with 2 CORPORATION terminals, and mount to a variety of single -gang Fire Protection Products: www.gentex.com back boxes. 10985 Chicago Dr., Zeeland, MI 49464 616/392 -7195 1- 800/436 -8391 FAX: 616/392 -4219 Gentex corporation reserves the right to make changes to the product data sheets at their discretion Printed on Recycled Paper GX0301 01-2 t ' ` v ulheQlocFt ILA .,--- �e M Ea ` i ,.i_ ,awl i Helping People Take Action • SERIES MB MOTOR BELLS Description Wheelock's Series MB Motor Bells provide a better engineered motor bell for fire and life safety alarm systems. The Wheelock Series MB Bells include higher dBA, low current draw, built -in trimplate for semi -flush mounting, low frequency aluminum shells, and low RFI ""° noise. The motor for Series MB Bells is a durable, high torque. permanent magnet motor selected for its high performance and long r " life. These DC vibrating Series MB Motor Bells are offered in 6" and 10" SERIES MB shell sizes in both 12 and 24 VDC models. Series RSSP Sync /Non -Sync retrofit plates are used in conjunction with the Series MB Motor Bell when combination appliances are �a required. The Series RSSP retrofit plates are available with either Multi- Candela or single candela strobes and easily mount to a 4" square or Wheelock SBL -2 backbox. All Series RSSP strobe`` X appliances meet or exceed the requirements of NFPA 72 (National Fire . Alarm Code), ANSI 117.1 (American National Standard for ..0 � - ,•. , Accessible and Usable Buildings and Facilities), ADA (Americans with Disabilities Act) and UL Standard 1971 (Signaling Devices for the' Hearing Impaired). # f � The Series RSSP retrofit plates may be synchronized when installed with the Wheelock Series SM, DSM, Sync Modules or the PS- 12/24 -8 ; 0 Power Supply with Wheelock's patented sync protocol. Wheelock's .,. synchronized strobes offer an easy way to comply with ADA requirements concerning photo-sensitive epilepsy. REMOTE PLATE with SBL -2 4 q 9 P , , Features RSSP REMOTE PLATE • Approvals include: UL Standard 464, Factory Mutual (FM), • Built -in trimplate makes semi -flush mounting California State Fire Marshal (CSFM), New York (MEA) and simpler and less expensive. Chicago (BFP). • Screw terminals permit fast in -out field wiring of • Meets OSHA 29 Part 1910.165. #12 to 18 AWG wire. • High sound output with low current draw. • Polarized for DC supervision of NAC circuits. • Low frequency aluminum shells for better audibility • Operates on filtered or unfiltered DC. through walls, doors and other structures. • For combined audible (bell) and visual signaling, • 6" and 10" shell sizes in 12 or 24 VDC models. convenient retrofit plate assemblies are available • Integral RFI suppression to minimize included noise on with Multi - Candela or Single candela strobes the NAC circuit. (Refer to Fire Alarm Products Catalog for Series • Mounting options for surface, semi - flush, outdoor, and RSSP Sync /Non -Sync Strobes specifications and concealed conduit installation. technical information). . Ordering Information Model Number Order Code Shell Size Input Voltage Input Current dBA 10 Ft. Mounting NOTES: (VDC) P Options 1. Typical dBA at 10 feet is measured in an MB G6 - 12 - R 3942 6" 12 0.060 anechoicchamber. 2. For bells all 12 VDC MB- G6 -24 -R 3941 6" 24 0.030 models are UL rated for 92 D,E,J,K,N,R,S,Z 9.0 to 15.6 VDC and all 24 MB - G10 - - 3944 10" 12 0.060 VDC models for 18.0 to MB- G10 -24 -R 3943 10" 24 0.030 31.0 VDC. Copyright 2002 Wheelock, Inc. Al! rights reserved. Architects and Engineers Specifications The alarm appliances shall be Wheelock Series MB vibrating Motor Bells or approved equal. They shall be UL Standard 464 Listed for Fire Protective Service. Shells shall be aluminum in 6" or 10" diameter. Sound output at 10 feet shall be 92 dBA. The bells shall incorporate a permanent magnet motor and suppression circuitry to minimize RFI. They shall include a built -in trimplate for semi -flush mounting to a standard 4" square backbox, or surface mounting to Wheelock's indoor BB backbox or outdoor WBB backbox. For bell strobe applications, retrofit plates Wheelock Series RSSP with Multi - Candela or Single Candela strobes shall be used. All bell models shall be polarized for line supervision and shall have screw terminals for in -out field wiring of #12 to #18 AWG wire. Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be red enamel. Model Number Order Code Nominal Voltage Strobe Candela 'Average Current **Mounting (VDC) (AMPS) at listed VDC Options i RSSP- 24MCW -FR 9402 24 15/30/75/110 .050/.081/.133/.161 D,E,Z RSSP- 241575W -FR 7793 24 15 (75 on -axis) .065 D,E,Z RSSP- 121575W -FR 7798 12 15 (75 on-axis) . .170 D,E,Z • Average Current per actual Wheelock Production Testing at listed VDC. For SYNC MODULES / POWER SUPPLY _ Rated Average and Peak current across UL regulated voltage range for both Order Input Voltage Average Current Mounting Filtered DC and Unfiltered VRMS, see Installation Instructions Model Number Code (VDC) (AMPS) @ 24 VDC Options" " Refer to Data Sheet S7000 for Mounting Options #SM Sync Module is rated for 3.0 amperes @ 24 VDC. SM- 12/24 -R" 6369 24 .028 W # #DSM Sync Module is rated for 3.0 amperes per circuit. The maximum DSM-12/24-R" 6374 24 .035 W number of interconnected DSM modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. PS- 12/24 -8 " " 8114 120 VAC ## #Refer to Data Sheet S9001 or Installation Instructions P83862 for PS- 12/24 -8 Power Supply. Wiring Fig. 1 Bell Models Fig. 2 Retrofit Strobe AUDIBLE STROBE Plate Models (RSSP) �+ `, , Fri FROM FREGEOiNO - TONE %T :' �� APPLIANCE OR + 1„ APPLIANCE TO NEXT OR EOLR PRECEDING APPLIANCE FRCP II APPLIANCE } OR ENO -OF -LINE OR FACP RESISTOR FROM _ TO NEXT (EOLR) PRECEDING 97RO. OR STROBE OR 4, + EOLR FACP Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION • MADE IN THE USA Distributed By: NATIONAL SALES OFFICE 3 YEAR WARRANTY 800 631 - 2148 Canada 800 - 397 -5777 NEM E -Mail: Info@wheelockinc.com http: / /www.wheelockinc.com 273 BRANCHPORT AVENUE • LONG BRANCH, NJ 07740 • TEL: 732 - 222 -6880 • FAX: 732 - 222 -2588 S1500 Rev. 06/02