Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications
/, Oct 15 2007 2:29PM ROTH HERTING 5032632513 p.1 / A4fe 7 - d 5 4 Fax Transmittal Rom NG S 70 I TO: Dan Nelson FROM: Jesse Manselle (503) 793 -5573 COMPANY: City Of Tigard FAX NUMBER: (503) 624 -3681 PAGES (Including cover): 3 PHONE: (503) 639 -4171 DATE: 10/15/07 TIME: 2:35 RE: Holiday Inn Express Building Permit: MEC2007 -00549 CC: ® For Approval ❑ For Review ❑ Please Comment El Please Reply ❑ As Requested ❑ For Your Use El REMARKS: Dan, Out at the Holiday Inn Express there is no original roof framing details, for the condensing unit we plan to put on the roof. There is however an existing curb, from a five ton package unit that has been removed, that has been decked over and roofed. What I'm proposing to do is to utilize this curb and put our condenser on top. Since the average five ton package unit weighs 600 plus pounds and the condenser we plan on using only ways 248 pounds, I don't see how this could be a problem. With this I'm also sending a detail as to how I would utilize the curb and also a spec. with the weight of the unit we are using. Thank you for your time, Jesse Manselle Roth Heating & Cooling , PO Box 1265, Canby, OR 97013, Phone: 503.266.1249, Fax: 503.266.3478 N ' { UN1r/Lue N:fittL m N m CD N m 0 L ° NBC = 1D - _ w ° � JbGItVME1 9E1Diej ��� pp o . UN rt FM c.itigB O p\ 0 Oct 15 2007 2:29PM ROTH HERTING 5032632513 P.3 Product Catalog - Heat Pump Outdoor Units - 13H PD - Page 14 November 2006 • : rsedes February 2006 • O t' •rte0,i; �x .A:• -: TtiF ?: ;.. 4 °Y'_?3:+:iO4.c. ;Eatt'k.�Ti'a �:2ilr.ns �T;��.X�SI- �-`:a► - +, -.,.. �.; ; ,. 'i f,4'�FiU. "?'s.+lx:rr' General Model No. 13HPD-018 13HPD -024 13HPD -030 13HPD -036 13HPD -04 13HPD • :- 13HPD -060 Data Nominal Tonnage (kW) 1.5 (5.3) 2 (7.0) 2.5 (8.8) 3 (10.6) 3.5 (12.3) 4 (14.1) 5 (17.6) (, Sound Rating Number 76 dB 76 dB 76 dB 76 dB 80 dB 80 dB 80 dB Connections Liquid line o.d. - in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/B (9.5) 3/8 (9.5) 3/8 (9.5) (sweat) Vapor line o.d. - in. (mm) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 7/8 (22.2) 7/8 (22.2) 7/8 (22.2) 1 -1/8 (28.6) 2 Refrigerant R -22 charge furnished 6 lbs. 6 oz. 6 lbs. 3 oz. 8 lbs. 4 oz. 8 lbs. 10 oz. 10 lbs. 6 oz. 11 lbs. 12 oz. 16 lbs. 4 az. (2.89 kg) (2.81 kg) (3.74 kg) (3.91 kg) (4.71 kg) (5.33 kg) (7.37 kg) Outdoor Diameter - in. (mm) 18 (457) 18 (457) 18 (457) 18 (457) 22 (559) 22 (559) 26 (660) Fan No. of blades 3 3 4 4 4 4 4 Motor hp (W) 1/5 (149) 1/5 (149) 1/5 (149) 1/5 (149) 1/3 (249) 1/3 249) 113 (249) Shipping Data lbs. (kg) 1 package 136 (62) 150 (68) 170 (77) 178 (81) 210 (95) 248 (112) 298 (135) .ELECTRICAL DATA• 1, 'j 1 a_' .r3�,' I. , ,.. ; ; ^i ;'� = ; • _:_'' ! '` - c< _ , Line voltage data - 60 hz - 1 ph 208/230V 208/230V 208/230V 208/230V 208/230V 8/230V 208/230V 3 Maximum overcurrent protection (amps) 20 20 30 30 40 45 60 4 Minimum circuit ampaciy 12.3 14.0 18 19.4 22.9 25.7 34.3 Compressor Rated Load Amps 8.9 10.3 13.5 14.7 17 19.2 26 Condenser Fan Motor Full Load Amps 1.1 1.1 1.1 1.1 1.7 1.7 1.8 NOTE - Extremes of operating range are plus 10% and minus 5% of One voltage. t Sound Rating Number rated in accordance with test conditions Included in ARI Standard 270. 2 Refrigerant Charge sunGent for 15 ft. (4.6 rn) length of refrigerant lines. 3 NACR type dreuil breaker or fuse. C Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. ( • i f NOTE • Due to Lennox' ongoing commitment to quality, Spec+ficatlone, Raungs and Dimensions subject to change without notice and without incurring liability.. Improper installation, adjustment, alteration, service or maintenance can cause properly damage or personal injury. Installation and service must be performed by a quailed Installer and servicing agency. 02006 Lennox Industries Inc. \ AIR HANDLERS (CB261MR LENNOX :MERIT®SERIES Up J Hotizontil B_ ENGINEERING DATA Bulletin No. 21046 prvb 6 Y1\ CEEljkoroof 5 - 7 6(2 (//r-tAlffa91-'4( . E . SEP 17 2001 cn Y OFTiG A , r , • • , ' ' ",•"" DINGDIVISION ,.; . a 10:q' r ; 11 •-■ - ' • t • p ' • 1;` Nominal Capacity - 1.5 to 5 Tons Optional Electric Heat - 5 to 20 kW - --1 INBERIDENTIFICATIoN _ CB 26 UH - 030 - R - 230-1 Unit Type Minor Revision Number CB - Air Handler (Blower/Coil) Voltage Series 230 = 208 /230V -1 phase -60hz Configuration Metering Device UH = Up-Flow / Horizontal R = Factory Installed RFCIV (No R = TXV) Nominal Cooling Capacity 018 = 1.5 tons 042 = 3.5 tons 024 = 2 tons 048 = 4 tons 030 2.5 tons 060 5 tons 036 = 3 tons - - 4 S - —._� _ —_ ,_ _ _ _ 1-.. _ C ,iF.EATURE CONTENTS t ARI Ratings Page 9 Blower Data Page 4 . . a ":',, ,; Dimensions �id Page 7 u , Dimensions - Accessories Page 8 r.� , I1 Electrical Data Page 4 , '-:'' ' 5 4,, I I Electric Heat Data Page 5 „•:,, . : . i. Features Page 2 L -7 c . ,I fs' • Installation Clearances Page 4 Model Number Identification Page 1 U n_ i t6, �, L � Optional Accessories Page 4 p�. , '://:!.:( ! Specifications Page 4 1•40,"k;',,' . c.",":",..1 ,� _;�� ` l WARRANTY i ,rte All covered components - limited five years in = t•, �, �.:, residential applications, one year in non - residential f , , ,v , ` Cta applications. •z '1� Refer to Lennox Limited Warranty Certificate included ; + -, ;. ;, i ., ' with each unit for additional details. ::'.''.=;', ^ APPLICATIONS ` c;.„= _� .1.,, . -., � ' ” ' l ' 1.5 to 5 ton nominal sizes. ] �, bE, I ,;.t 3 Up -flow or horizontal applications. Optional down -flow kit 2 1' , , \ , �, ' ' , available for field conversion. . ` i , ( t, ,- ,.,,,,,,:;,,,N, • • Applicable to RFCIV systems in cooling applications. r C � i, CB26UH -048 applicable to expansion valve systems. . rr- L C � CG+ � V Optional field installed electric heaters available in several ; f ; , ,, ee, sizes for additive heating capacity. r G II APPROVALS Tested with matching air conditioners and heat pump units in the Lennox Research Laboratory environmental test 7 7 gip 'I room in accordance with ARI Standard 210/240 -2005. Optional electric heaters are rated in accordance with US Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations. 0 Refrigerant Line Connections Air handlers are UL Listed to US and Canadian safety Suction (vapor) and liquid lines have sweat connections standards and components within are bonded for that extended outside of the cabinet for ease of grounding to meet safety standards for servicing required connection. by CEC and NEC. See dimension drawing for locations. ISO 9001 Registered Manufacturing Quality System. © Copper Tube /Enhanced Fin Evaporator Coil REFRIGERANT SYSTEM Assembled in "A" configuration. O Refrigerant Flow Control IV Provides extra large surface and contact area, excellent All models (except -048) are applicable to Lennox RFCIV heat transfer and low air resistance for maximum • refrigerant metering system.o,ince RFCIV efficiency. Refer to ARI Ratings Housing (Factory Installed) Precise circuiting for uniform refrigerant distribution. in this bulletin for ®® ®/ .roi Precisely spaced ripple -edged aluminum fins fitted to . match -ups. ( durable seamless copper tubes. RFCIV accurately �® ® ® '' "- Fins are strengthened to resist bending and are equipped meters refrigerant in / Strainer with collars that grip tubing for maximum contact area. seal Lanced fins provide maximum exposure of fin surface to system. ° ' " "g (discard) \® Refrigerant control is t t_a,, air stream. Liquid Line - Long life copper tubing is easy to service. accomplished by exact sizing of Fitting - g pp g y refrigerant metering orifice. Rifled tubing provides superior heat transfer. Principle of Lennox RFCIV system involves matching indoor Flared shoulder tubing joints and silver soldering provide coil with proper bore size of orifice in metering device. tight, leakproof joints. RFCIV system equalizes pressure shortly after compressor Coil thoroughly factory tested under high pressure to stops, unit starts unloaded, eliminating need for additional insure leakproof construction. controls. OPTIONS „ Expansion Valve Expansion Valve Kit (All models except -048) CB26UH -048 is equipped with a wide range thermal Thermal expansion valve kit can be ordered separately for expansion valve. Chatleff style fitting. Factory installed field installation. Refer to outdoor unit bulletin ARI internal to cabinet. match -up tables for proper valve required. - - CB26UH•R • 1.5.to 5 ton Alr- Handlers / - Page 2 - - . • • f, r j TEATU,RES . _ ,_�� —� _� FILTER (NOT FURNISHED) Horizontal Support Frame Kit Filter is not furnished and must be field supplied. Provides support of unit in horizontal applications. Filter rack furnished in cabinet for easy filter installation. Consists of (2) 1 x 1 -1/2 x 32 -5/8 in. and (2) 1 x 3 x 53-7/8 See Specifications tables for filter sizes. in. painted heavy gauge cold rolled steel support channels with assembly and suspending holes. ()BLOWER Bolts and nuts furnished for field assembly. Resiliently mounted two -speed motor. Suspending rods must be field provided. Choice of blower speeds. See blower performance tables. Side Return Unit Stand (Up -Flow Only) Speed changes easily accomplished by a simple wiring Raises unit 16 in. above floor for side return air duct change. connection. Blower is easily removed from unit for servicing. Eliminates need for wooden platform construction. Time Delay Blower Relay All aluminum construction. Relay allows 30 second blower "on" delay before See Dimension Drawing. continuous fan or cooling operation and 30 second blower Wall Hanging Bracket Kit (Up -Flow Only) "off" delay after continuous fan or cooling operation. Allows unit to be hung on wall at any height. CONTROLS Consists of heavy gauge steel support brackets (one for air handler unit, one for wall mount). • 0 Transformer and Blower Cooling Relay Screws furnished for fastening one bracket to unit. 24 volt transformer and blower cooling relay furnished as Bolts for fastening one bracket to wall are field provided. standard. ELECTRICAL Factory installed in the unit control box. OPTIONS OPTIONS 0 Electric Heat Thermostat Field install internal to unit cabinet. .; See Thermostat bulletins in Controls section and Lennox Available in several kW sizes. . , ;":. r, ' ; - ;- Price Book for a complete list of thermostats. See Electric Heat tables. vo •'- F� ' " ()CABINET H wound nichrome heating a.: a ' L b ' elements exposed directly in i .: Constructed of heavy gauge galvanized steel. p y :`i, '=s, air stream resulting in instant , . ' Powder paint finish. 3 ' ; . :,: , Completely insulated with foil faced fiberglass insulation. heat r rausfer, low element , ;5 Removable panels provide complete service access. temperatures and long `` `•: Filter access door for easy filter replacement. service life. ; z' Electrical inlets provided in sides and top of cabinet. See Each element equipped with dimension drawing for locations. accurately located limit control with fixed temperature off Knock -outs in cabinet for drain connections for up -flow setting and automatic reset. (left and right) and horizontal applications. See dimension Thermal sequencer relay brings elements on and off line, drawing. in sequence and equal increments, with time delay Up- Flow /Horizontal Capability (Optional Down -Flow) between each Shipped for up -flow and horizontal left-hand discharge. Initiates and terminates blower operation. Factory assembled May be field converted to horizontal right -hand air F t ry assem blled d with furnished coonntrtroed as controls installed an standard. and wired. discharge by repositioning horizontal drain pan. Facit Optional down -flow kit available for field conversion. Electric heat control wiring plugs into mating connector on air handler unit. 0 Anti - Microbial Dual Position Drain Pans Circuit Breaker Models Anti - Microbial additive resists growth ECB26 -5CB, ECB26 -7CB, ECB26 -10CB, ECB26 -15CB, of mold and mildew on drain pan ' ECB26 -20CB heaters are equipped with circuit breakers . which improves indoor air quality for overload and short circuit protection. and reduces drain line blockage. Factory wired and mounted on electric heat unit. Drain pans designed for up -flow or horizontal applications. Current sensitive and temperature actuated. Deep, corrosion resistant high temperature engineered Manual reset. polymer drain pans have dual pipe drains. Circuit breakers qualify as disconnect means at unit in many See dimension drawing. areas, eliminates the need for field provided disconnect. OPTIONS Consult local electrical code in your area. Circuit Breaker Cover Kit Down -Flow Combustible Floor Base (Down -Flow Only) Flexible plastic cover protects circuit breaker. Additive base required for models with electric heat Recommended in areas with high humidity to prevent installed in down -flow position on combustible floors. nuisance tripping. Down -Flow Conversion Kit Single -point Power Source Control Box ,- Required for field conversion to down -flow position. Kit Control Box may be used with optional electric heat when consists of drip shields and 2 brackets for repositioning single power supply is connected to multi- circuit electric heat. coil and drain pan. Field installs external to the unit cabinet on either side or top. Duct Adaptor Kit Constructed of heavy gauge steel, baked enamel finish, Kit allows direct connection of the ductwork to the return prepunched mounting holes, electrical inlet knockouts, and air opening of the air handler, not required if an external terminal strip. filter is used or if unit is installed on a platform in up -flow Removeable cover provides easy access. applications. See dimension drawing. Dimensions (H x W x D) - 7 x 7 x 4 in. - - . . - -- --- CB26UH -R - -1.5 to -5.ton Air Handlers / Page -3 -- - - - r fiSPECIFICATIONST- - - -- - - - ' ° --- - -- - -- -- '-- - - ===- • -- -' -• -- ._ .. _, _ ,�.. - - -, ----- - General _ Model Number CB26UH CB26UH CB26UH CB26UH CB26UH CB26UH CB26UH F e...' Data -018 -R -024 -R -030 -R -036 -R -042 -R -048 -060 -R v Nominal tonnage 1.5 2 2.5 3 3.5 4 5 Connections Suction/Vapor line (o.d.) - in. sweat 3/4 3/4 7/8 7/8 7/8 7/8 7/8 Liquid line (o.d.) - in. sweat 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Condensate - in. fpt (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4 Metering device type and orifice size 0.057 0.061 0.072 0.074 0.082 TXV 0.098 Indoor Net face area - ft. 4 4 4.88 4.88 5.84 7.58 8.76 Coil Tube outside diameter - in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 3 3 3 3 3 3 3 Fins per inch 15 14 14 14 14 14 14 Blower Wheel nom. diameter x width - in. 10 x 6 10 x 6 11 x 8 11 x 8 11 x 8 11 x 8 11 -1/2 x 9 Blower motor output - hp 1/4 1/4 1/4 1/3 1/3 1/2 1/2 1 Filters Size of filter - in. 16 x 20 x 1 16 x 20 x 1 18 x 20 x 1 18 x 20 x 1 18 x 25 x 1 18 x 25 x 1 18 x 25 x 1 Shipping Data -1 package - lbs. 129 131 148 148 172 177 190 VELECTRICAL/D'ATA - • _, — —� —•_ , -__ �, r _ _ Voltage - 1 phase (60 hz) 208/240V 208/240V 208/240V 208/240V 208/240V 208/240V 208/240V 2 Maximum overcurrent protection (unit only) 15 15 15 15 15 15 15 3 Minimum circuit ampacity (unit only) 1.5 1.5 1.6 2.0 2.0 2.6 4.1 FtO PTiIONAL ACCESSORIES - 'M UST:BE'ORDERED EXTRA - ^ _ _ • '-- 1 Circuit Breaker Cover Kit 93M85 • • • • 12W95 • • Down -Flow Combustible Floor Base 12W96 • • 12W97 • Down -Flow Conversion Kit 12W61 • • • Duct Adaptor Kit X8103 . X8104 • Horizontal Support Frame Kit 56J18 • • • Side Return Unit Stand (Up -Flow Only) 45K32 • • Single Point Power Source Control Box 21H39 (for Electric Heat) Wall Hanging Bracket Kit (Up -Flow Only) 45K30 • • 1 Filter is not furnished and must be field supplied. • 2 HACR type circuit breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 °F. WE �iBLOR-t ATA • - - . -- ; - - -- - -' 7.- , , f / • • • _ • , BLO _-_ ___- __.. -_.w._ _, __ _w -- - - - -- External Air Volume (cfm) - at Specific Blower Taps Static CB26UH -018 -R CB26UH.024-R CB26UH -030 -R CB26UH -036 -R CB26UH -042 -R CB26UH-048 CB26UH -060 -R Pressure - in. w.g. High Low High Low High Low High Low High Low High Low High Low .10 1020 755 1040 1000 1350 1145 1560 1405 1940 1785 1945 1870 2160 2075 .20 960 715 980 940 1290 1090 1480 1340 1845 1705 1860 1790 2065 1985 .30 885 675 905 870 1225 1030 1390 1270 1745 1615 1765 1700 1960 1885 • .40 800 625 815 785 1150 960 1290 1185 1630 1515 1660 1600 1845 1775 .50 690 570 705 680 1065 875 1170 1090 1495 1400 1540 1485 1710 1645 .60 525 500 535 530 965 775 1015 975 1330 1265 1395 1350 1550 1495 NOTE - PJI air data measured external to unit with dry coil and 1 inch non-pleated air filter in place Electnc heaters have no appreciable air resistance. ! 1 ' NSTALLATIOWCLEARANCES 77 - 7-7 Cabinet 0 inch (0 mm) Plenum and Outlet duct on air handler units 1 inch (25 mm) Plenum and Warm air duct within 3 feet (914mm) of cabinet 1 inch (25 mm) Floor — Combustible _CB26UH -R -1.5 to.5.ton Air Handlers /_Page 4 ... - . - - _ -- .- _ .__ . o ELECTERIC HEAT DATA - -` - -- _ - -- - __ - -- - -- - - _ - = - -- - SINGLE PHASE ELECTRIC HEAT CB26UH -018 -R / CB26UH -030 -R CB26UH -024 -R Blower Blower 2 Minimum 3 Maximum Motor 2 Minimum 3 Maximum Motor Circuit Overcurrent Description Input Full Circuit Overcurrent Full Ampacity Protection Volt kW 1 Btuh Load Ampacity Protection Load Circuit Circuit Circuit Circuit Amps Amps 1 2 1 2 . 5 kW ECB26 -5 (99M64) 208 3.8 12,800 1.5 24.7 4 25 1.6 24.8 - - - 4 25 - - - Terminal Block 220 4.2 14,300 1.4 27.8 30 1.5 27.9 - - - 30 - - - ECB26 -5CB (99M65) Circuit Breaker 230 4.6 15,700 1.4 27.8 30 1.5 27.9 - - - 30 - - - 240 5.0 17,100 1.4 27.8 30 1.5 27.9 - - - 30 - - - 7.5 kW ECB26 -7 (99M67) 208 5.6 19,200 1.5 35.5 4 40 1.6 35.6 - - - 4 40 - - - Terminal Block 220 6.3 21,500 1.4 40.8 45 1.5 40.9 - - - 45 - - - ECB26 -7CB (99M66) Circuit Breaker 230 6.9 23,500 1.4 40.8 45 1.5 40.9 - - - 45 - - - 240 7.5 25,600 1.4 40.8 45 1.5 40.9 - - - 45 - - - 10 kW ECB26 -10 (99M68) 208 7.5 25,600 1.5 47.0 4 so 1.6 47.1 - - - 4 50 - - - Terminal Block 220 8.4 28,700 1.4 53.8 60 1.5 54.0 - - - 60 - - - ECB26 -10CB (99M69) Circuit Breaker 230 9.2 31,400 1.4 53.8 60 1.5 54.0 - - - 60 - - - 240 10.0 34,100 1.4 53.8 60 1.5 54.0 - - - 60 - - - 15 kW ECB26 -15CB (99M70) 208 7.5 25,600 1.5 - - - - - - 1.6 47.1 22.8 4 50 4 25 Circuit Breaker 220 8.4 28,700 1.4 - - - - - - 1.5 54.0 26.0 60 30 230 9.2 31,400 1.4 - - - - - - 1.5 54.0 26.0 60 30 240 10.0 34,100 1.4 - - - - - - 1.5 54.0 26.0 60 30 SINGLE PHASE ELECTRIC HEAT CB26UH - 036 - R CB26UH - 042 - R Blower 2 Minimum 3 Maximum Blower 2 Minimum 3 Maximum Motor Circuit Overcurrent Motor Circuit Overcurrent Description Input Full Ampacity Protection Full Ampacity Protection Volt kW 1 Btuh Load Circuit Circuit Circuit Circuit Load Circuit Circuit Circuit Circuit Amps 1 2 1 2 Amps 1 2 1 2 5 kW ECB26 -5 (99M64) . 208 3.8 12,800 2.1 25.5 - - - 30 - - - 2.1 25.5 - - - 30 - - - Terminal Block 220 4.2 14,300 2.0 28.6 - - - 30 - - - 2.0 28.6 - - - 30 ECB26 -5CB (99M65) Circuit Breaker 230 4.6 15,700 2.0 28.6 - - - 30 - - - 2.0 28.6 - - - 30 - - - 240 5.0 17,100 2.0 28.6 - - - 30 - - - 2.0 28.6 - - - 30 - - - 7.5 kW ECB26 -7 (99M67) 208 5.6 19,200 2.1 36.3 . - - - 4 40 - - - 2.1 36.3 - - - 4 40 - - - Terminal Block 220 6.3 21,500 2.0 41.6 - - - 45 - - - 2.0 41.6 - - - 45 ECB26 -7CB (99M66) Circuit Breaker 230 6.9 23,500 2.0 41.6 - - - 45 - - - 2.0 41.6 - - - 45 - - - 240 7.5 25,600 2.0 41.6 - - - 45 - - - 2.0 41.6 - - - 45 - -- 10 kW ECB26 -10 (99M68) 208 7.5 25,600 2.1 47.7 - - - 4 50 - - - 2.1 47.7 - - - 4 50 -.- - Terminal Block 220 8.4 28,700 2.0 54.6 - - - 60 - - - 2.0 54.6 - - - 60 - - - EC626 -1006 (99M69) 230 9.2 31,400 2.0 54.6 - - - 60 - - - 2.0 54.6 - - - 60 ' Circuit Breaker 240 10.0 34,100 2.0 54.6 - - - 60 - - - 2.0 54.6 - - - 60 - - - 15 kW ECB26 -15CB (99M70) 208 11.3 38,400 2.1 47.7 22.8 4 50 4 25 2.1 47.7 22.8 4 50 4 25 Circuit Breaker 220 12.6 43,000 2.0 54.6 26.0 60 30 2.0 54.6 26.0 60 30 230 13.5 47,000 2.0 54.6 26.0 60 30 2.0 54.6 26.0 60 30 240 15.0 51,200 2.0 54.6 26.0 60 30 2.0 54.6 26.0 _ 60 30 NOTE - Circuit 1 Minimum Circuit Ampacity Includes the Blower Motor Full Load Amps. 1 Electnc heater capacity only - does not include additional blower motor heat capacity. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 °F l- 3 HACR typo breaker or fuse. 4 Bold indicates that the circuit breaker on "CB" circuit breaker models must be replaced with size shown. - - ._ . - _ _ _ - CB26UH -R -1.5 to 5 ton Air Handlers / Page 5 , ELECTRICIH EAT 'D'ATA � SINGLE PHASE ELECTRIC HEAT CB26UH -048 CB26UH -060 -R Blower 2 Minimum 3 Maximum Blower 2 Minimum 3 Maximum Motor Circuit Overcurrent Motor Circuit Overcurrent Description Input Full Ampacity Protection Full Ampacity Protection Volt kW 1 Btuh Load Load Amps Circuit Circuit Circuit Circuit A Circuit Circuit Circuit Circuit 1 2 1 2 (240V) 1 2 1 2 5 kW ECB26 -5 (99M64) 208 3.8 12,800 2.6 26.1 - - - 30 - - - 4.1 28.0 - - - 30 - - - Terminal Block 220 4.2 14,300 2.5 29.2 - - - 30 - - - 3.9 30.9 - - - 35 ECB26 -5CB (99M65) Circuit Breaker 230 4.6 15,700 2.5 29.2 - - - 30 - - - 3.9 30.9 - - - 35 - - - 240 5.0 17,100 2.5 29.2 - - - 30 - - - 3.9 30.9 - - - 35 - - - 7.5 kW ECB26 -7 (99M67) 208 5.6 19,200 2.6 36.9 - - - 4 40 - - - 4.1 38.8 - - - 4 40 - - - Terminal Block 220 6.3 21,500 2.5 42.2 - - - 45 - - - 3.9 43.9 - - - 45 ECB26 -7CB (99M66) Circuit Breaker 230 6.9 23,500 2.5 42.2 - - - 45 - - - 3.9 43 • - - 45 - - - 240 7.5 25,600 2.5 42.2 - - - 45 - - - 3.9 - - 45 - - - 10 kW ECB26 -10 (99M68) 208 7.5 25,600 2.6 48.3 - - - 4 50 - - - 4.1 50.2 - - 60 - - - Terminal Block 220 8.4 28,700 2.5 55.2 - - - 60 - - - 3.9 . i - 60 ECB26 -1006 (99M69) 230 9.2 31,400 2.5 55.2 - - - 60 - - - 3.9 57.0 - - - 60 - - - Circuit Breaker 240 10.0 34,100 2.5 • - - - 60 - - - 3.9 - - - 60 - - 15 kW ECB26 -15CB (99M70) 208 11.3 38,400 2.6 22.8 4 50 4 25 4.1 50.2 22.8 60 4 25 Circuit Breaker 220 12.6 43,000 2.5 . 26.0 60 30 3.9 57.0 26.0 60 30 230 13.5 47,000 2.5 55.2 26.0 60 30 3.9 57.0 26.0 60 30 240 15.0 51,200 2.5 55.2 26.0 60 30 3.9 57.0 26.0 60 30 20 kW ECB26 -20CB (99M71) 208 15.0 51,200 2.6 48.3 45.1 4 50 4 50 4.1 50.2 45.1 60 4 50 Circuit Breaker 220 16.8 57,300 2.5 55.2 52.1 60 60 3.9 57.0 52.1 60 60 230 18.4 62,700 2.5 55.2 52.1 60 60 3.9 57.0 52.1 60 60 240 20.0 68,200 2.5 55.2 52.1 60 60 3.9 57.0 52.1 60 60 NOTE - Circuit 1 Minimum Circuit Ampacity includes the Blower Motor Full Load Amps 1 Electnc heater capacity only - does not include additional blower motor heat capacity. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements Use wires suitable for at least 167 °F 3 HACR type breaker or fuse 4 Bold indicates that the circuit breaker on "CB" circuit breaker models must be replaced with size shown. _.CB26UH -R .T.1.5 to 5 ton Air_Handlers / P_age_6 _ _ .. _ _ _ _ _ • � ' . ' . �� —__ � ~ _ , ..�.���U���U0»U���� ���'^���FLO�y1pO��I3�I0��'U�O8�mW'`~ —~— ^���� . — - ' �__.'_-___- __- _� 1( C • � B , : n.uws»oo»as | | • mm | / ° LOW VOLTAGE Right Side Only AIR FLOW O A CONDENSATE DRAIN PIPING PLATE (4) FILTER ACCESS (2-1/4 x 3-3/4) SUCTION LINE � `� p.'an�mmmmmm"om.uno,mv LINE T oum°vmmvmmmmm, no n -- 1 LIQUID / ' ____+ m meu/,xuno/o nn,nmu.mo E � v,./ unit m."mvnuum,u � —� ) r n���mu�om°unnommonu) / ' ' / �� � � n 1 n nw \= & (19) | | T | l■— 2-1s ~~~~ 2-1m 1-1/2 -~-` 1-1/2 (64) ( (38) (38) FRONT VIEW SIDE VIEW -018.-024 -030, -036 -042.-048 -060 Dimension inches mm inches mm inches mm inches mm A 46-3/4 1187 51 1295 54 1372 60 1524 B 18-1/2 470 21-1/4 540 21-1/4 540 21-1/4 540 C 22 559 22 559 26 880 26 600 D 11 279 12-1/2 318 12 305 11-3/4 298 E 16 406 10'1/2 470 16-3/4 425 17 432 F 5-1/2 140 6 152 4 102 4 ' 102 G 13-1/2 343 16 408 16 • 406 16 406 H 19 483 19 483 23 584 23 584 Supply Air Depth 17 432 17 432 21 533 21 533 Opening Width 16-1/2 419 19-1/4 489 19-1/4 489 19-1/4 489 ' ' - . CooauU!Izt !. 1.5 tma Air Handlers / Page / FACCES jolt YIDIMEN51QN = 1 1 NCHEk141 ) ? ^- ' -` - ',-$ DOWN -FLOW COMBUSTIBLE FLOOR BASE SIDE RETURN UNIT STAND 1 (38) -1/2 i (Up -Flow Only) 38 HANDLER -11110 f— D --► / SUPPLY A AIR Opening ik OPENING 16 IF B (406) _� 1 Lr J 1 -1/z 4 6 .r I�� I (36) (152) E `� TOP VIEW 7 FRONT SID !I6- r API 11 C ADJUSTABLE (6) 21 -114 20 (508) to 1 ( 0) ALL ( UN TS 1.4111 DOWN -FLOW I I I I 1 -112 (38) COMBUSTIBLE FLOOR BASE SIDE VIEW Usage -018 -024 -030 -036 - 042 - 048 -060 (12W95) (12W96) (12W97) in. mm in. mm in. mm A (floor) 19 483 21 -3/4 552 21 -3/4 552 B 16 -7/8 429 19 -5/8 498 19 -5/8 498 C 23 -1 /8 587 23 -1/8 587 27 -7/8 708 D (floor) 19 -1/2 495 19 -1/2 495 26 -3/4 679 , _CB26UH -R -1.5 to_5 ton Air Handlers /. Page.8 _ _ _ _ _ -ARI cRATINGS - - - = "- - - -_. ._j -.= -- - __ - ..` - . - AIRaCON'DEMONERS' 1 ARI Standard 210/240 Ratings Cooling Efficient Expansion Capacity y ToWa Unit Indoor Unit Model No. Device Btuh SEER I EER 13ACD -018 WITH RFC 1.5 TON 18,300 •.1 13.00 11.00 1 1665 I 0B26UH -018 -R 1 0.055 (27J64) 13ACD-024 WITH RFC 2 TON 24,800 1 13.00 1 11.00 2255 I CB26UH -024 -R 1 0.062 (66J90) 13ACD -030 WITH RFC 2.5 TON 29,600 1 13.00 1 11.00 1 2690 1 CB26UH -030 -R 1 0.070 (66J91) 13ACD -036 WITH RFC 3 TON 34,600 I 13.00 1 11.00 I 3145 1 CB26UH -036 -R 1 0.076 (97M78) 13ACD -042 WITH RFC 3.5 TON 41,000 1 13.00 11.00 3725 1 CB26UH -042 -R 'Factory Installed RFC (0.082) 13ACD-048 WITH RFC 4 TON 45,000 1 13.00 11.00 4090 CB26UH -048 -R 1 (11W10) 13ACD -060 WITH RFC 5 TON 59,000 1 13.00 1 11.00 5365 1 CB26UH -060 -R 1 0.099 (27J87) AC13-018 WITH RFC 1.5 TON 18,300 1 13.00 11.00 ' 1665 1 CB26UH -018 -R 1 0.055 (27J64) AC13 -024 WITH RFC 2 TON 24,800 I 13.00 1 11.00 2255 1 CB26UH -024 -R 1 0.062 (66J90) AC13-03O WITH RFC 2.5 TON 29,600 1 13.00 1 11.00 1 2690 1 CB26UH -030 -R 1 0.070 (66J91) AC13-036 WITH RFC 3 TON 34,600 I 13.00 11.00 3145 1 CB26UH -036 -R 1 0.076 (97M78) AC13-042 WITH RFC 3.5 TON 41,000 1 13.00 1 11.00 1 3725 1 CB26UH -042 -R 'Factory Installed RFC (0.082) AC13-048 WITH RFC 4 TON 45,000 I 13.00 11.00 4090 1 CB26UH -048 -R 1 (11W10) AC13 -060 WITH RFC 5 TON 59,000 ' 1 13.00 1 11.00 1 5365 1 CB26UH -060 -R 1 0.099 (27J87) 1 Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95 °F outdoor air temperature, 80 °F db / 67 °F wb entenng evaporator air with 25 ft. of connecting refngerant lines 2 Factory Installed RFCIV device on Indoor unit MUST be replaced with RFCIV orifice shipped with the air conditioner. CB26UH -R -1.5 to 5 ton Air Handlers / Page 9 _ • .ARI - RATINGS - " _ HEAT',PUM 1 ARI Standard 210/240 Ratings Capacity - Btuh Efficiency Total Watts COP Expansion Indoor Unit Model No. Device High Low HSPF High Low High Low Cooling Temp. Temp. Cool Heating Heating SEER I EER IV I V Heat Heat Heat Heat 13HPD -018 1.5 TON 18,000 16,800 10,600 13.00 11.50 7.70 6.90 1565 1425 1310 3.46 2.36 CB26UH -018 -R (Up -Flow /Horizontal) RFC Factory .057 Installed 13HPD -024 2 TON 24,000 22,000 13,900 13.00 11.50 7.70 7.05 2085 1825 1715 3.54 2.38 CB26UH-024 -R (Up- Flow /Horizontal) Factory Installed RFC (0.061) 13HPD -030 2.5 TON 31,000 28,600 17,900 13.00 11.00 7.70 7.10 2820 2405 2180 3.48 2.40 CB26UH-030 -R (Up- Flow /Horizontal) Factory Installed RFC (0.072) 13HPD -036 3 TON 35,200 33,800 21,000 13.00 11.00 7.70 7.10 3200 2760 2515 3.58 2.44 CB26UH -36-R (Up-Flow / Horizontal) Factory Installed RFC (0.074) 13HPD -042 3.5 TON 41,500 41,000 26,400 13.00 11.00 8.50 7.45 3775 3780 3275 3.18 2.36 CB26UH-042 -R (Up- Flow /Horizontal) RFC Factory .082) Installed 13HPD -060 5 TON 57,000 55,000 35,600 13.00 11.00 7.70 7.30 5060 4890 4295 3.30 2.42 CB26UH -060 -R (Up-Flow/Horizontal) Factory Installed RFC (0.098) HP13 -018 1.5 TON 18,000 16,800 10,600 13.00 11.50 7.70 6.90 1565 1425 1310 3.46 2.36 CB26UH-018 -R (Up-Flow /Horizontal) Factory Installed RFC (0.057) HP13-024 2 TON 24,000 22,000 13,900 13.00 11.50 7.70 7.05 2085 1825 1715 3.54 2.38 CB26UH-024 -R (Up- Flow/Horizontal) Factory Installed RFC (0.061) HP13 -030 2.5 TON 31,000 28,600 17,900 13.00 11.00 7.70 7.10 2820 2405 2180 3.48 2.40 CB26UH-030 -R (Up- Flow/Horizontal) RFC Factory .072) Installed H P13-036 3 TON 35,200 33,800 21,000 13.00 11.00 7.70 7.10 3200 2760 2515 3.58 2.44 CB26UH -036 -R (Up- Flow/Horizontal) Factory Installed RFC (0.074) HP13-042 3.5 TON 41,500 41,000 26,400 13.00 11.00 8.50 7.45 3775 3780 3275 3.18 2.36 CB26UH-042 -R (Up- Flow/Horizontal) RFC Factory 0,082 Iled HP13 -060 5 TON 57,000 55,000 35,600 13.00 11.00 7.70 7.30 5060 4890 4295 3.30 2.42 CB26UH-060 -R (Up- Flow/Horizontal) Factory Installed • RFC (0.098) NOTE - When used with gas furnaces, a dual -fuel control (i.e. FM21) or a control system with dual -fuel capabilities (i.e. Harmony Ill, LZP -2 or LZP-4) must be used (ordered extra) t Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refngerant lines; Cooling Ratings - 95 °F outdoor air temperature and 80 °F db /67 °F wb entenng indoor coil air. • High Temperature Heating Ratings - 47 °F db /43 °F wb outdoor air temperature and 70 °F db entenng indoor coil air Low Temperature Heating Ratings - 17 °F db /15 °F wb outdoor air temperature and 70 °F db entenng indoor coil air. • CB26UH -R - 1.5_to -5 ton Air Handlers / Pagel 0 l r REVISIONS Sections Description of Change General Changed CB26UH-048-R to CB26UH-048 (with factory installed TXV) Electrical Data Revised Minimum Circuit Ampacity for CB26UH-036 and -042 models Electric Heat Data Revised all Minimum Circuit Ampacity and Maximum Overcurrent Protection data. • . . . NMI 1)1. �� C Us REGISTERED QUALITY SYSTEMS LENNOX Visit at www.lennox.com For the e latest st technical information, www.lennoxdavenet.com Contact us at 1- 800.4 - LENNOX NOTE - Due to Lennox' ongoing committment to quality. Specifications. Ratings and Dimensions subject to change without notice and without incurring liability Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2007 Lennox Industries Inc. r , 1 ox, D-00 L-f 1 • 1 HEAT PUMP UNITS , _,, ----_ ----- , N. ' p 1311411PID LE1111 j REC, 3 17 sw JIViERIMSERIES 2001 ilit22' ENGINEERING DATA Bulletin No. 210428 CITY • - CiARD Of Ti May 2007 Supersedes January 2007 ITILDING DIVISION , - ' ' ;.,-,, c-- ' - - .:L- - ,--_ -- --- -- -_-_ -7 -))) s' :t , ., , ----- --,..... r; '. '..,, • ■ , + ,. . 737-71777-71 irr'-‘-',--, •-i , : , , 4..„.,,,,__,.., , 1 ■ 11 .1 ■ , ' I. 1 , ' • !. ■ I ; , • ' I ;' ifitlitt 1 • 1 ' I I ' ; I ..•!( ' .' I ■ , • I, 11 ''' I ■ I' • 1 ' 1 I II. 1 1 I I I . ; I ;I 110 ' N r • I -.- I' ."-■.., , - 0 ■■ ;-, , 6; I) ; 1 ‘s• Ni s, 2 ,.. % ,,, ,-, . , • . i _ . I t ; , - , 1 ,-- •; 1' ' - ,. ' ire. 1 I ,-; :! I .-.-•^ r 1 0- .. '''-' ' '- . ••-k ; r' 1' '' ■ k ,,,' • ' ; " :1 .. ` ''. .41,;;;• - '' • ■ ;'....,-. .• SEER up 'to 14.5 1.5 to 5 Tons Cooling Capacity - 18,50010 58,000 Btuh Heating Capacity - 16,700 to 55,500 Btuh 1 111110DelDNUMBERIIDENIIIIFICATION ' . " ' ' ' , ,_ -____, , . , , , , , ,.,.; ---.--- '''''-' -- ----' —. 13 HP D -024 - 230 - 2 T Minor Revision Number Nominal SEER - -T I— Voltage 230V 208 /230V - 1 phase - 60hz Unit Type Nominal Cooling Capacity HP = Heat Pump Outdoor Unit 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons Series 036 = 3 tons 042 = 3.5 tons 048 = 4 tons 060 = 5 tons CONTENTS ARI Indoor Coil /Air Handler Substitution Page 8 0 ' ~ L7-;-:-- - :' ARI Rating Tables Pages 9 -15 _. Dimensions Page 7 '� ii ,` fi t . Electrical Data Page 5 r ' �`I ~- �� - � Pag 2 } ,. 1 ;rl .'1's--,_ l4 �. :.. Features ,' Field Wiring Page 6 ''''4', l Installation Clearances Page 6 , Model Number Identification Page 1 ? b Optional Accessories Page 5 �� Outdoor Sound Data Page 6 • 1 I r� , 7 Specifications Page 5 ` +.‘ - t�' Revisions Page 15 ,mo( 6 �� vn, WARRANTY ?,:' t c, •/ { u ; i Compressor - limited warranty for five years in • ► - 1.' � -. ` resid installations and five years in non - residential ,' .N ". i }I `p' installations. 3 ,- " I , ' ; l �I i1 All other covered components - five years in residential installations and one year in non - residential • >., d -, t.. `p , . 0 i \ .. it `-� ''" '' I I ° r s. 1 ._., . , , Refer to Lennox Equipment Limited Warranty certificate \ + included with unit for specific details. \\ r '� APPROVALS \ ' p . :. Certified in Accordance with the USE certification '` program, which is based on ARI Standard 210/240. Sound rated in Lennox reverberant sound test room in Accordance with test conditions included in ARI Standard 270 -95. Tested in the Lennox Research Laboratory environmental test room. Rated According to U.S. Department of Energy (DOE) REFRIGERANT SYSTEM test procedures. Units and components within bonded for grounding to Outdoor Coil Fan meet safety standards for servicing required by UL, NEC Direct drive fan moves large air volumes uniformly and CEC. through entire outdoor coil for high refrigerant cooling and Units are UL and ULC listed. heating capacity. ISO 9001 Registered Manufacturing Quality System. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. APPLICATIONS Fan motor has sleeve bearings and is inherently SEER up to 14.5. protected. Heating COP up to 3.94. Motor totally enclosed for maximum protection from HSPF (Region IV) up to 8.50. weather, dust and corrosion. . 1.5 through 5 tons. Rain shield on motor provides additional protection from Single phase power supply. moisture. Vertical air discharge allows concealment behind shrubs Louvered steel top fan guard furnished as standard. at grade level or out of sight on a roof. Fan service access accomplished by removal of top Designed for applications with remotely located indoor air panel. handler units or gas furnaces with indoor add -on coils. Copper tube /Enhanced Fin Coil . When heat pumps are used with gas furnaces, a dual -fuel 8 Lennox designed and fabricated coil. control (i.e. FM21) or a control system with dual -fuel Ripple -edged aluminum fins. capabilities (i.e. Harmony III LZP -2 or LZP-4) must be Copper tube construction. used (ordered extra). Lanced fins provide maximum exposure of fin surface to See Indoor Coils and Air Handlers sections for indoor unit air stream resulting in excellent heat transfer. data. Fin collars grip tubing for maximum contact area. Units shipped completely factory assembled, piped and Flared shoulder tubing connections /silver soldering wired. Each unit is test operated at the factory insuring construction. proper operation. Coil is factory tested under high pressure to ensure . Installer must set outdoor unit, connect refrigerant lines leakproof construction. and make electrical connections to complete job. Entire coil is accessible for cleaning. For expanded ratings, see www.lennoxdavenet.com. © PVC coated steel wire coil guard furnished as standard. 13HPD -1.5 to 5 Ton Heat Pump / Page 2 1 !JFEATiU�RES _ _ =_ _ _ _ _ r� — REFRIGERANT SYSTEM (CONTINUED) Refrigerant Line Kits . 0 Expansion Valve - Outdoor Unit Refrigerant lines (suction & liquid) are shipped refrigeration Designed and sized specifically for use in heat pump clean. Lines are cleaned, dried, pressurized and sealed at system. factory. Sensing bulb is located on the suction line between the Suction line fully insulated. reversing valve and the compressor to sense evaporator Lines are stubbed at both ends. suction temperature in any cycle. Not available for -060 models and must be field fabricated. Factory installed and piped. °COMPRESSOR High Capacity Liquid Line Drier Scroll Compressor Factory installed in the liquid line, the drier traps moisture Compressor features high _ or dirt that could contaminate the refrigerant system. efficiency with uniform suction j,�'' - 100% molecular- sieve, bead type bi -flow drier. flow, constant discharge flow . ci__ . 0 Reversing Valve and high ; - h volumetric efficiency.. 4 -way interchange reversing valve effects a rapid change and quiet operation. I -' , in direction of refrigerant flow resulting in quick Compressor consists of two . ij d`0 changeover from cooling to heating and vice versa. involute spiral scrolls matched • ,`. :;� 4 ') Valve operates on pressure differential between outdoor together to generate a series of - unit and indoor unit of the system. Factory installed. crescent shaped gas pockets :� Refrigerant Flow Control - between them. Units applicable to expansion valve systems or RFC During compression, one scroll systems when matched with specific evaporator coils. remains stationary while the RFCIV METERING SYSTEM other scroll orbits around it. _ i O IFICE BODY RFCIV Gas is drawn into the outer , � � (On Coil) °BULLET" pocket, the pocket is sealed as ORIFICE the scroll rotates. �, -_ As the spiral movement fi r' 0-RING LIQUID continues, gas pockets are pushed to the center of the ,� . ;,�� LINE scrolls. Volume between the pockets is simultaneously O LINE LIQUID / r reduced. SCREEN ®. ` ' When pocket reaches the center, gas is now at high SEAL pressure and is forced out of a port located in the center of ®I® NUT SWEAT the fixed scrolls. CONNECTION During compression, several pockets are compressed RFCIV: simultaneously resulting in a smooth continuous Accurately meters refrigerant in system. compression cycle. Refrigerant control is accomplished by exact sizing of Continuous flank contact, maintained by centrifugal force, refrigerant metering orifice. minimizes gas leakage and maximizes efficiency. The principle involves matching indoor coil with proper Scroll compressor is tolerant to the effects of slugging and bore size of orifice in metering device. contaminants. If this occurs, scrolls separate, allowing Equalizes pressure shortly after compressor stops, unit liquid or contaminants to to be worked toward the center starts unloaded, eliminating need for additional controls. and discharged. Furnished with air handler. Low gas pulses during compression reduces operational OPTIONS sound levels. . Check/Expansion Valve Kits Compressor motor is internally protected from excessive Must be ordered extra and field installed on certain indoor current and temperature. units. Muffler in discharge line reduces operating sound levels. • See ARI Ratings tables. Compressor is installed in the unit on resilient rubber Chatleff -style fitting. mounts for vibration free operation. High Pressure Switch Kit OPTIONS Protects the system from high pressure conditions that Compressor Crankcase Heater can be a result of fan failure or a blocked /dirty coil. Protects against refrigerant migration that can occur Manual reset. during low ambient operation. Loss of Charge Kit Compressor Sound Cover Helps protect the compressor from damage due low A reinforced vinyl compressor cover containing a 1 -1/2 refrigerant charge conditions. inch thick batt of fiberglass insulation. SPST, normally- closed switch, automatic reset switch All open edges are sealed with a one -inch wide hook and mounted on suction line. loop fastening tape. 13HPD -1.5 to 5 Ton Heat Pump / Page 3 , '1 . FEATURES -CONTROLS Thermostat O Defrost Control Thermostat not furnished with unit. See Thermostat Solid -state time /temperature defrost control is furnished bulletins in Controls Section and Lennox Price Book. as standard equipment. © CABINET Control initiates a defrost cycle every 30, 60 or 90 minutes Heavy gauge steel cabinet with five station metal wash of compressor "on" time at outdoor coil temperatures process. below 42 °F (factory setting 60 minutes). Powder paint finish provides superior rust and corrosion Anti -short cycle, timed -off control incorporated into the protection. board. Painted base section. High and low pressure switch monitoring with five -trip Control box is conveniently located with all controls lockout. factory wired. Diagnostic LED's furnished as an aid in troubleshooting. Corner patch plate allows access to compressor Conveniently located in control box. components. OPTIONS Drainage holes are provided in base section for moisture Compressor Hard Start Kit removal. Single -phase units are equipped with a PSC compressor O Refrigerant Line Connections, Electrical Inlets, motor. This type of motor normally doesn't need a Service Valves potential relay and start capacitor. Sweat connection vapor and liquid lines are located on In conditions such as low voltage, this kit may be required corner of unit cabinet. to increase the compressor starting torque. Fully serviceable brass service valves prevent corrosion Compressor Low Ambient Cut -Off and provide access to refrigerant system. Vapor valve can Non - adjustable switch (low ambient cut -out) prevents be fully shut off, while liquid valve may be front seated to compressor operation when outdoor temperature is manage refrigerant charge while servicing system. below 35 °F. Refrigerant line connections and field wiring inlets are ' Freezestat located in one central area of cabinet for easy access. See Installs on or near the vapor line of the indoor coil or on the dimension drawing. suction line. Senses suction line temperature and cycles the OPTIONS compressor off when suction line temperature falls below Hail Guards it's setpoint. Constructed of louvered heavy gauge steel painted to Opens at 29 °F and closes at 58 °F. match cabinet. Indoor Blower Off Delay Relay Surrounds unit on all four sides to prevent damage to the Delays the indoor blower -off time during the cooling cycle. coil. See ARI Rating Tables for usage. Mounting Base Low Ambient Kit Provides permanent foundation for outdoor units. Heat pump units will operate satisfactorily down to 45 °F High density polyethylene structural material is outdoor air temperature without any additional controls. lightweight, sturdy, sound absorbing and will withstand the Kit can be added in the field enabling unit to operate rigors of the sun, heat, cold, moisture, oil and refrigerant. properly down to 30 °F. Will not mildew or rot. Crankcase heater and freezestat should be installed on Can be shipped singly or in packages of 6 to a carton. compressors equipped with a low ambient kit. Unit Stand -Off Kit A compressor lock -out thermostat should be added to Black high density polyethylene feet are available to raise terminate compressor operation below recommended unit off of mounting surface away from damaging operation conditions. moisture. Mild Weather Kit Four feet are furnished per order number. Heat pump units operate satisfactorily in the heating mode at outdoor air temperatures up to 75 °F. Mild Weather Kit can be field installed, allowing heating operation above 75 °F. Monitor Kit - Service Light • Contains ambient compensating thermistor and service light thermostat. For use with thermostats requiring input for indicator lights. - Outdoor Thermostat Kit An outdoor thermostat can be used to lock out some of the electric heating elements on indoor units where two stage • control is applicable. Outdoor thermostat maintains the heating load on the low power input as long as possible before allowing the full • power load to come on the line. Thermostat kit and mounting box must be ordered extra. • 13HPD -1.5 to 5 Ton Heat Pump / Page 4 . ^ ` ` ' . - -'-------- ----- ------------ , -, . �^�= ~-_-_ ' �� --��---------���~~ - -~^~---� - ------ ���P���o���Po������P����N��� 4 � 1 �wpo'�� �Y�.� . Data Nominal Tonnage 1.5 2 2.5 3 3.5 4 5 Sound Rating Number 76 76 76 76 80 80 80 ' onnections Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 (sweat) Vapor line o.d. - in. 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8 Refrigerant R-22 charge furnished 6 lbs. 6 oz. 6 lbs. 3 oz. 8 lbs. 4 oz. 8 lbs. 10 oz. 10 lbs. 6 oz. 11 lbs. 12 oz. 16 lbs. 9oz. Outdoor let ace area Outer coil 15.21 1521 13.30 1521 18.66 21.11 29.09 Coil sq. ft• Inner coil - - - - - - 1280 14.50 17.95 20.31 28.16 Tube diameter-in. no. of rows 5/16 5/16 5/16 5/16 5/16 5/16 5/16 No. of rows 1 1 2 2 2 2 2 Fins per inch 222 22 22 22 22 22 22 Outdoor Dia. - in. - No. of Blades 18 - 3 18 - 3 1U'4 18'4 22-4 22 - 4 2O'4 Fan Motor hp 1/5 1/5 1/5 1/5 1/3 1/3 1/3 Cfm 2400 2400 2440 2450 3890 3890 4550 Rpm 1130 1130 1095 1100 1080 1085 830 Watts 166 166 194 190 400 375 307 Shipping Data - lbs. 1 package � ______ ___ __ _ 178 _21} _ 248 298 |InE����U�U0A�/DAT�� . __ ____ _____ __` Line voltage d h 208/230V 208/230V 208/230V 208/230V 20B23OV 208/230V 208Q3UV 20 20 30 30 40 45 60 » K4aximumnvu"ourmntpm��iun(amps) * Minimum circuit ompacity 12.3 14.0 18 19.4 22.9 25.7 34.3 Compressor Rated Load Amps - 8.9 10.3 13.5 14.7 17 19.2 26.0 Locked Rotor Amps 41 56 72.5 83 95 129 •14B Power Factor 0.98 0.98 0.98 0.80 0.95 0.86 8.86 Outdoor Full Load Amps 1.1 1.1 1.1 1.1 1.7 1.7 1.8 Fan Motor Locked Rotor Amps 1.9 1.9 1.9 1.9 4.1 4.1 2.9 - ; ' TT ' ^ 's •• L�����N�������������ww� �`^� _������� - �m�pre000,��uh�ameMeo�r 90P12 ~ ^ ^ Compressor Hard Start Kit � 10J42 • • • • • 81J69 • • Compressor Low Anm,u Ambient 45F08 • • • • • • • • Compressor Sound Cover 69J03 • • ^ • ^ • ^ • • • Freezestat 3/8 in. tubing 93G35 • • • ~ • ^ • • 1/2 in. tubing 39H29 • • • • • • • 5/8 in. tubing 50A93 • • • • • • • Hail Guards 92M89 • • ' ^ 92M88 • 12W21 • . 92M90 • 94M94 ' High Pressure Swit Kit �h� 94J46 • • • • .• • . • Indoor Blower � Off Delay 58M81 • ^ ^ ^ ^ ^ ^ ^ Loss of Charg Kit �� 84M23 • • • • • • • : � nwponb�ntK� 27J00 • • • • • •• • ' • Mild Weather Kit �e,� 33M07 '^ • ^ • • • Monitor Kit or�'Gunviwe Light 76F53 • • • • • • • . Mounting Base 69J06 • • • • 69J87 • • • Outdoor Thermostat 56A87 • • • • • • • . Thermostat Mtg. Box - US 31461 • • • • • • • Kit Mtg. Box - Cdn 33A09 • • • • • • • Refrigerant L15-*1'20 L154140 • • • ' Line Sets L15-41-30 L15-41-50 ' L15'85'30 L15'6540 • • • L15'G5'5O Field Fabricate • ' Unit Stand-Off Kit 94J45 • • • • • • • NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. 2 Refn nt charge sufficient m,1on length of refngerant lines. ' o xxoR type circuit »muku,",mvo. 4 Refer to National or Canadian Electncal Code manual to determine wire, fuse and disconnect size requirements. Crankcase Neater and Freezestat are recommended with Low Ambient KIt 1uwpo'1'su,s Ton Heat Pump / Page n ,41NSlALL'ATlO.N(GI -IIN 4 NOTES: See NOTES Service clearance of 30 in. (762 mm) must be maintained on one if of the sides adjacent to the control box. \\1II , Clearance to one of the other three sides must be 36 in. (914 mm) f Seems See Clearance to one of the remaining two sides may be 12 in. (305 NOTES -- - -- ", mm) and the final side may be 6 in. (152 mm). lilll� A clearance of 24 in. (610 mm) must be maintained between two 4 units. CONTROL See NOTES BOX i 48 in. (1219 mm) clearance required on top of unit. IELDIWIRIN. -- r - - - :DISCONNECT) SWITCH B A - Two Wire Power (see Electrical Data) O lLeyotn O __ r - - - -- : OPTIONAL : B - Two or Three Wire Power (size to heater capacity) I ELHEATIC -I r - - --I - - -- J r DISCONNECT: C - Twelve Wire Low Voltage - 18 ga. minimum OPTIONAL (By others) I L - - - J - Fourteen Wire Low Voltage with Optional Outdoor Thermostat OUTDOOR I L HERMOSTAJ LENNOX D - Eight Wire Low Voltage - 18 ga. minimum INDOOR UNIT r THERMOSTAT: - Ten Wire Low Voltage with Optional Outdoor Thermostat LENNOX (Optional) 9 P OUTDOOR - Fiel Wiring s - UNIT p C All winng must c onform to NEC Not or Furni CEC a nd hed local electrical codes. rouTDOO , - ' - -, _ ~' _- - `� Octave Band Sound Power Levels dBA, re 10 Watts 1 Sound 1 Unit Center Frequency - HZ Rating Model No. Number (dB) 125 250 500 1000 2000 4000 8000 13HPD -018 70.5 67 68 67 65.5 60.5 57.5 76 13HPD -024 67.5 66.5 69.5 70 66.5 60.5 56 76 13HPD -030 70.5 69.5 71.5 72.5 67.5 63.5 60 76 13HPD -036 69.5 70.5 71.5 69.5 68.5 62.5 60.5 76 13HPD -042 75.5 79.5 79.5 75.5 70 63.5 58.5 80 13HPD -048 75.5 74.5 75 73.5 70 66.5 63.5 80 13HPD -060 76 76.5 76.5 74.5 69.5 66 61.5 80 NOTE - the octave sound power data does not include tonal correction 1 Tested according to ARI Standard 270 test conditions • 13HPD -1.5 to 5 Ton Heat Pump / Page 6 .^ • '` __'- _ ___---_---_-_''---_, - ' .- _--'-�- _'__-' -'-_.__�.-----�-'- --' - . 0K�N�NE�U��������-���C�8E�� � ___ 4-3/8 4-3/8 . - AIR + 1(111) ` ' - 4-3/8 r . = ...._ .�� � (111 111) O Iii INL� INLET oprmwx UNIT _� ^ �` an�o�pmr�> �`� �,� (Fielomvmomd) \ / II AIR 41\\\ \ 4 , j AIR COIL DRAIN OUTLETS (Around penmeter of base) I e• »�. 1 _~lvAPon LINE ( ^�~~� CONNECTION ~ |wLsT[1 AIR T.-| L~| LIQUID m� CONNECTION 6-3/8 4-30 TOP VIEW (162) (111) TOP VIEW BASE SECTION | | CONDENSER ~'~~'~~~~* AIR ' ` COIL FAN ;i _i Il COMPRESSOR 11111111 C 8 6■.. 111111111 | 1 - Cal I E D C1 7 1 1 0 1 1VS il --............................. ELECTRICAL INLETS � L e�~ T v \ L3 / 8 \ �k 2 � ��800 M T & 1) T SIDE VIEW 3/4<18V 11 UNIT SIDE VIEW STAND-OFF KIT (4) (Field Installed) A B C Model No. • in. mm in. mm in. mm 13MPD'18 1311PD'024 24-1/4 616 33-1/4 845 32-1/2 820 . 13MPD'030 13MPD'030 24-1/4 816 291/4 743 28-1/2 724 131-1PD'042 28-1/4 718 33-1/4 845 .82'1/2 826 ' 13MPD'048 28'1/4' 718 37 940 36-1/4 921 13HPD'080 32-1/4 819 43-1/4 1099 42-1/2 1080 . 1oxpo'1.5 Ton Heat Pump / Page 7 ARI I AT1NGS —UNDO ORsGOI L. % AIRIHANDLERaS U.BSITi17iUfTiION: Substituting Coils in the ARI Tables Most R -22 and R-410A indoor coils and air handlers are The expansion device is based on the size of the outdoor ' the same except for the factory installed expansion unit. The factory installed RFC or TXV on the device. C33 coils can be used in place of the CX34 coils, CX34 /CBX26UH /CBX27UH /CBX32MV /CBX32M must CB26UH, CB27UH, CB3OM and CB31MV air handlers be replaced to correspond to the outdoor unit. The correct can be used in place of the CBX26UH, CBX27UH, TXV's are: CBX32M and CBX32MV, respectively. 1.5 -3 ton heat pump units 56J19 3.5 -5 ton heat pump units 56J20 Example: A four -ton heat pump is being installed. The ARI table shows that CBX32MV -048 is a matching air handler. A CB31MV-51 with a 91MO2 TXV can be used in its place. UP -FLOW COILS AIR HANDLERS R-410A R -22 R-410A R - 22 CX34- 18/24A -6F = C33 -24A -2 CBX26UH -018 = CB26UH -018 -R CX34- 18/24B -6F = C33 -24B -2 CBX26UH -024 = CB26UH -024 -R CX34- 18/24C -6F = C33 -24C -2 CBX26UH -030 = CB26UH -030 -R CX34- 19A -6F = C33 -19A -2 CBX26UH -036 = CB26UH -036 -R CX34- 25A -6F = C33 -25A -2 CBX26UH -042 = CB26UH -042 -R CX34- 25B -6F = C33 -25B -2 CBX26UH -048 = CB26UH-048 CX34- 30A -6F = C33 -30A -2 CBX26UH -060 = CB26UH-060 -R CX34- 30B -6F = C33 -30B -2 CBX27UH-018/024 = CB27UH -018/024 CX34- 30C-6F = C33 -30C -2 CBX27UH -030 = CB27UH-030 CX34- 31A -6F = C33 -31A -2 CBX27UH -036 = CB27UH-036 CX34-31B-6F = C33-31B-2 CBX27UH -042 = CB27UH -042 CX34-36A -6F = C33 -36A -2 CBX27UH -048 = CB27UH -048 CX34- 36B -6F = C33 -36B -2 CBX27UH -060 = CB27UH-060 CX34- 36C-6F = C33 -36C -2 CBX32M- 018/024 = CB30M -21/26 CX34- 38A -6F = C33 -38A -2 CBX32M -030 = CB30M -31 CX34-38B -6F = C33 -38B -2 CBX32M -036 = CB30M-41 CX34- 42B -6F = C33 -42B -2 CBX32M -042 = CB30M-46 CX34- 43B -6F = C33 -43B -2 CBX32M -048 = CB30M -51 CX34- 43C -6F = C33 -43C -2 CBX32M -060 = CB30M -65 no equivalent C33 -44C -2 CBX32MV -018/024 no equivalent CX34- 44/488 -6F = C33 -48B -2 CBX32MV -024/030 no equivalent CX34- 44/48C -6F = C33 -48C -2 CBX32MV -036 = CB31MV -41 CX34- 49C -6F = C33 -49C -2 CBX32MV -048 = CB31MV -51 CX34- 50/60C -6F = C33- 50/60C -2 CBX32MV -060 = CB31MV -65 CX34- 60D -6F = C33 -60D -2 CBX32MV -068 no equivalent CX34- 62C -6F = C33 -62C -2 CX34- 62D -6F = C33 -62D -2 13HPD - 1.5 to 5 Ton Heat Pump / Page 8 • ARI Standard - 210 /240 Ratings Capacity - Btuh Efficiency Total Watts COP Indoor Unit Model No. Expansion High Low HSPF Device • Cooling Temp. Temp. Cool High Low High Low Heating Heating SEERI EER IV I V Heat Heat Heat Heat 13HPD-018 1.5 TON R -22 Air Handlers Air Handlers 18,000 16,800 10,600 13.00 11.50 7.70 6.90 1565 1425 1310 3.46 2.36 CB26UH -018 -R (Up- Flow /Horizontal) Factory RFC (0.061) 18,500 16,800 10,600 13.00 11.50 7.70 6.90 1570 1425 1310 3.46 2.36 CB26UH -024 -R (Up- Flow /Horizontal) 2 56J19 18,600 16,700 10,600 13.00 11.50 7.70 6.95 1555 1405 1295 3.48 2.40 5 CB26UH -018 -R (Up -Flow /Horizontal) 2 56J19 18,600 17,400 12,100 13.00 11.50 7.70 6.70 1580 1445 1340 3.52 2.64 3 CB30M -21/26 (Multi- Position) Factory TXV 18,600 16,700 10,600 13.00 11.50 7.70 6.70 1580 1460 1360 3.36 228 3 CB30U -21/26 (Up -Flow) Factory TXV 13HPD -024 2 TON R -22 Air Handlers Air Handlers 24,000 22,000 13,900 13.00 11.50 7.70 7.05 2085 1825 1715 3.54 2.38 CB26UH -024 -R (Up- Flow /Horizontal) 'Factory RFC (0.061) 24,200 22,000 14,000 13.00 11.00 7.70 6.90 2170 1880 1775 3.42 2.30 3 CB30M -21/26 (Multi- Position) Factory TXV 24,200 22,000 14,000 13.00 11.00 7.70 6.90 2170 1880 1775 3.42 2.30 3 CB30U -21/26 (Up -Flow) Factory TXV 24,600 22,000 13,900 13.00 11.50 7.70 7.05 2140 1825 1715 3.54 2.38 5 CB26UH -024 -R (Up -Flow / Horizontal) 2 56J19 25,600 22,000 13,800 13.00 11.50 7.70 6.65 2155 1810 1850 3.56 2.18 3 CB30M -31 (Multi- Position) Factory TXV 25,600 22,000 13,800 13.00 11.50 7.70 6.65 2155 1810 1850 3.56 2.18 3 CB30U -31 (Up -Flow) Factory TXV R -22 Up -Flow Indoor Coils + Furnaces Up -Flow Coils + Furnaces 24,000 21,400 13,500 13.50 11.50 7.70 6.75 2030 1875 1735 3.34 228 C33 -24B 4 G6OUHV -36B -090 2 56J19 24,000 21,600 13,600 13.00 11.50 7.70 7.05 2050 1800 1670 3.52 2.38 C33 -30A 4 G6OUHV -36A -070 2 56J19 24,000 21,600 13,600 13.50 11.50 7.70 7.10 2020 1775 1645 3.56 2.42 C33 -30B 4 G6OUHV -36B -090 2 56J19 24,000 21,600 13,700 13.00 11.50 7.70 7.05 2060 1800 1680 3.52 2.38 C33 -30B 4 G61MPV-36B-045 2 56J19 24,000 21,600 13,600 13.00 11.50 7.70 7.05 2050 1800 1670 3.52 2.38 C33 -30B 4 G61MPV -36B -070 2 56J19 Down -Flow Indoor Coils-+ Furnaces Down -Flow Coils + Furnaces 24,400 21,800 13,800 13.00 11.50 7.70 7.15 2090 1790 1665 3.56 2.42 CR33 -24B -F 4 G61MPV -36B -045 2 56J19 24,400 21,800 13,700 13.00 11.50 7.70 7.15 2080 1785 1660 3.58 2.42 CR33 -24B -F 4 G61MPV -36B -070 2 56J19 24,600 21,800 13,800 13.00 11.50 7.70 7.20 2090 1775 1655 3.60 2.44 CR33 -24A -F 4 G600FV -36A -070 2 56J19 Horizontal Indoor Coils + Furnaces Horizontal Coils + Furnaces 23,000 21,600 13,600 13.00 11.00 7.70 6.80 2035 1885 1725 3.36 2.30 CH23 -21 4 G6OUHV -36B -090 2 56J19 23,200 21,400 13,600 13.00 11.00 7.70 7.00 2035 1830 1685 3.42 2.36 CH23 -31 4 G6OUHV -36B -090 2 56J19 24,200 21,600 13,600 13.00 11.50 7.70 6.80 2075 1870 1740 3.38 2.28 CH33- 24/30A -2F 4 G60UHV -36A -070 2 56J19 NOTE - These are the only approved system match -ups For other matches, contact the Lennox Applications Department • NOTE - Ratings for C33 coils include all cased and uncased coils. NOTE - When used with gas furnaces, a dual -fuel control (i.e. FM21) or a control system with dual -fuel capabilities (i.e Harmony III, LZP -2 or LZP -4) must be used (ordered extra). 1 Certified in accordance with USE certification program which is based on ARI Standard 210 /240 with 25 ft. (7 6 m) of connecting refngerant lines, Cooling Ratings - 95 °F (35 °C) outdoor air temperature and 80 °F (27 °C) db /67 °F (19 °C) wb entering indoor coil air. High Temperature Heating Ratings - 47 °F (8 °C) db /43 °F (6 °C) wb outdoor air temperature and 70 °F (21 °C) db entenng indoor coil air. Low Temperature Heating Ratings - 17 °F (- 8.3 °C) db /15 °F ( -9 4 °C) wb outdoor air temperature and 70 °F (21 °C) db entenng indoor coil air. 2 Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (If equipped). 3 Blower must be capable of time-off blower delay. Indoor Blower Off Delay Relay (58M81) is recommend for field installation 4 Blower control must be set for a time-off blower delay 5 Most popular air handler combination 13HPD -1.5 to 5 Ton Heat Pump / Page 9 iARL/RATINGS- 1 ARI Standard 210/240 Ratings Capacity - Btuh Efficiency Total Watts COP Expansion High Low HSPF Indoor Unit Model No. Device Low Cooling lHeating Heating SEERIEER IV I V Cool HtatlHeat HtatlHe t 13HPD - 030 2.5 TON R -22 Air Handlers Air Handlers 30,600 28,600 17,900 13.00 11.00 7.70 6.60 2700 2445 2415 3.42 2.18 3 CB30U -31 (Up -Flow) Factory TXV 30,800 28,600 17,800 13.00 11.00 7.70 6.65 2690 2435 2405 3.44 2.16 3 CB30M -31 (Multi- Position) Factory TXV 31,000 28,600 17,900 13.00 11.00 7.70 7.10 2820 2405 2180 3.48 2.40 CB26UH -030 -R (Up- Flow /Horizontal) Factory RFC (0.072) 31,000 28,600 17,900 13.00 11.00 7.70 7.10 2710 2405 2180 3.48 2.40 5 CB26UH -030 -R (Up -Flow / Horizontal) 2 56J19 31,000 28,200 17,500 13.50 11.50 7.70 6.65 2615 2355 2325 3.50 2.20 4 CB31MV -41 (Multi- Position) Factory TXV 31,200 28,200 17,500 13.50 12.00 7.70 6.70 2600 2350 2320 3.52 2.20 4 CB27UH -030 (Up -Flow / Horizontal) Factory TXV 31,200 28,200 17,400 13.50 12.00 7.70 6.70 2600 2335 2300 3.54 2.22 4 CB27UH -036 (Up -Flow / Horizontal) Factory TXV R -22 Up -Flow Indoor Coils + Furnaces Up -Flow Coils + Furnaces 30,400 28,200 17,600 13.00 11.50 7.70 6.70 2630 2480 2300 3.34 2.24 C33 -36A 4 G6OUHV -36A -070 2 56J19 30,600 28,000 17,400 13.50 11.50 7.70 6.80 2575 2420 2240 3.40 2.28 C33 -36B 4 G6OUHV -36B -090 2 56J19 30,600 28,400 17,700 13.00 11.50 7.70 6.75 2650 2470 2295 3.36 2.26 C33 -36B 4 G61MPV -36B -045 2 56J19 30,600 28,200 17,600 13.00 11.50 7.70 6.75 2620 2465 2285 3.36 2.26 C33 -36B 4 G61MPV -36B -070 2 56J19 30,600 28,000 17,400 13.50 11.50 7.70 6.75 2590 2435 2250 3.38 226 C33 -36C 4 G61MPV -36C -090 2 56J19 Down -Flow Indoor Coils + Furnaces Down -Flow Coils + Furnaces 30,800 28,600 17,800 13.00 11.50 7.70 7.20 2660 2340 2120 3.58 2.46 CR33- 30/36A -F 4 G6ODFV- 36A -070 2 56J19 30,400 28,400 17,800 13.00 11.00 7.70 7.15 2655 2395 2145 3.48 2.42 CR33 -24B -F 4 G6ODFV- 36B-090 2 56J19 30,800 28,600 17,800 13.00 11.50 7.70 720 2665 2350 2130 3.56 2.44 CR33 -30 /36B -F 4 G61MPV- 36B-070 2 56J19 31,000 28,600 17,900 13.00 11.50 7.70 7.20 2700 2365 2150 3.54 2.44 CR33- 30/36B -F 4 G61MPV-36B-045 2 56J19 31,000 28,400 17,700 13.00 11.50 7.70 7.25 2635 2320 2100 3.58 2.46 CR33- 30/36C -F 4 G61MPV-36C-090 2 56J19 31,200 28,400 17,700 13.50 11.50 7.70 7.25 2630 2295 2085 3.62 2.48 CR33- 30/36B -F 4 G6ODFV- 36B-090 2 56J19 Horizontal Indoor Coils + Furnaces Horizontal Coils + Furnaces 30,200 28,200 17,700 13.00 11.50 7.70 7.05 2615 2390 2170 3.46 2.38 CH23-41 4 G6OUHV- 36B-090 2 56J19 30,400 28,400 17,700 13.00 11.00 7.70 6.70 2660 2500 2320 3.32 224 CH33- 36B-2F 4 G61MPV- 36B -070 2 56J19 30,600 28,200 17,500 13.00 11.50 7.70 6.75 2620 2460 2280 3.36 2.24 CH33- 36B-2F 4 G6OUHV- 36B-090 2 56J19 30,800 28,200 17,600 13.00 11.50 7.70 6.70 2635 2430 2325 3.40 2.22 CH33 -36C-2F 4 G61MPV- 36C-090 2 56J19 NOTE - These are the only approved system match -ups. For other matches, contact the Lennox Applications Department NOTE - Ratings for C33 coils include all cased and uncased coils. NOTE - When used with gas furnaces, a dual -fuel control (i.e. FM21) or a control system with dual -fuel capabilities (i.e Harmony III, LZP -2 or LZP-4) must be used (ordered extra) I Certified in accordance with USE certification program which Is based on ARI Standard 210/240 with 25 ft (7 6 m) of connecting refrigerant lines: Cooling Ratings - 95 °F (35 °C) outdoor air temperature and 80 °F (27 °C) db/67 °F (19 °C) wb entering indoor coil air High Temperature Heating Ratings - 47 °F (8 °C) db /43 °F (6 °C) wb outdoor air temperature and 70 °F (21 °C) db entering indoor coil air. " Low Temperature Heating Ratings - 17°F (- 8.3 °C) db /15 °F ( -9 4 °C) wb outdoor air temperature and 70 °F (21°C) db entenng indoor coil air 2 Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped). 3 Blower must be capable of time-off blower delay Indoor Blower Off Delay Relay (58M81) is recommend for field installation 4 Blower control must be set for a time-off blower delay. • 5 Most popular air handler combination 13HPD -1.5 to 5 Ton Heat Pump / Page 10 ARI IRATIN'GS. _ � �� ARI Standard 210/240 Ratings _..__ > Capacity - Btuh Efficiency Total Watts COP Expansion High Low HSPF IHi Heat Heat Heat Heat h Low High Low Indoor Unit Model No. Device Cooling Temp. Temp. Cool Heating Heating SEER' EER IV I V 13HPD-036 3 TON Air Handlers Air Handlers 34,400 33,600 20,800 13.00 11.00 7.70 6.75 3150 2825 2695 3.48 2.26 3 CB30M-41 (Multi- Position) Factory TXV 34,400 33,600 20,800 13.00 11.00 7.70 6.70 3155 2830 2710 3.48 2.24 3 CB30U•41146 (Up -Flow) Factory TXV 34,600 33,600 20,800 13.00 11.00 7.70 6.80 3130 2790 2670 3.52 2.28 3 CB30M -46 (Multi-Position) Factory TXV 34,800 33,400 20,800 13.00 11.00 7.70 6.80 3125 2765 2650 3.54 2.30 4 CB31MV -41 (Multi- Position) Factory TXV 34,800 33,200 20,600 13.50 11.00 7.70 6.70 3165 2705 2570 3.60 2.34 4 CB27UH -036 (Up -Flow / Horizontal) Factory TXV 35,200 33,800 21,000 13.00 11.00 7.70 7.10 3165 2760 2515 3.58 2.44 5 CB26UH -036 -R (Up -Flow / Horizontal) 2 56J19 35,200 33,800 21,000 13.00 11.00 7.70 7.10 3200 2760 2515 3.58 2.44 CB26UH -36-R (Up -Flow / Horizontal) Factory RFC (0.074) 36,400 33,000 20,400 14.00 12.00 7.70 6.70 3035 2700 2505 3.58 2.38 4 CB27UH-042 (Up -Flow / Horizontal) 2 56J19 R - 22 Up - Flow Indoor Coils + Furnaces Up - Flow Coils + Furnaces 34,200 33,200 20,600 13.00 11.00 7.70 6.80 3080 2875 2610 3.38 2.32 C33 -36B 4 G6OUHV -36B -090 2 56J19 34,200 33,200 20,600 13.00 11.00 7.70 6.75 3065 2885 2615 3.38 2.30 C33 -36C 4 G61MPV- 36C -090 2 56J19 34,200 33,200 20,600 13.00 11.00 7.70 6.80 3080 2875 2610 3.38 2.32 C33 -42B 4 G6OUHV- 36B -090 2 56J19 34,400 33,200 20,800 13.00 11.00 7.70 6.80 3100 2865 2615 3.40 2.32 C33 -36C 4 G61MPV- 60C-090 2 56J19 34,600 33,200_ _20,600. 13.00. 11.00..71.0. 6.85 3085 2840 2590 3.42 2.32 C33 -36C 4 G60UHV -609 -110 2 56J19 34,600 33,200 20,800 13.00 11.00 7.70 6.80 3095 2850 2605 3.42 2.34 C33 -36C 4 G61MPV -60C -110 2 56J19 Down - Flow Indoor Coils + Furnaces Down - Flow Coils + Furnaces 34,600 33,400 20,800 13.00 11.00 820 7.20 3060 2675 2425 3.66 2.52 CR33- 30/36B -F 4 G6ODFV- 36B-090 2 56J19 34,600 33,400 20,800 13.00 11.00 8.20 7.20 3075 2695 2435 3.64 2.50 CR33- 30/36C -F 4 G61MPV- 36C -090 2 56J19 34,600 33,200 20,600 13.00 11.00 7.70 7.05 3060 2760 2495 3.52 2.42 CR33-48B -F 4 G600FV- 36B-090 2 56J19 34,800 33,600 20,800 13.00 11.00 820 7.20 3105 2680 2440 3.68 2.50 CR33- 30/36C -F 4 G61MPV- 600-090 2 56.119 35,000 33,600 20,800 13.00 11.00 820 7.25 3100 2665 2430 3.70 2.50 CR33-30/36C-F 4 G61MPV- 60C-110 2 56J19 Horizontal Indoor Coils + Furnaces Horizontal Coils + Furnaces 34,000 33,200 20,800 13.00 11.00 7.70 7.00 3075 2785 2510 3.50 2.42 CH23-41 4 G6OUHV- 36B -090 2 56J19 34,000 33,200 20,800 13.00 11.00 7.70 7.00 3065 2795 2510 3.48 2.42 CH23-41 4 G61MPV- 36C -090 2 56J19 34,400 33,400 20,800 13.00 11.00 7.70 7.05 3090 2765 2505 3.54 2.44 CH23-41 4 G61MPV- 60C-110 2 56J19 34,600 33,200 20,600 13.00 11.00 7.70 6.80 3075 2835 2625 3.44 2.30 CH33 -36C-2F 4 G61MPV- 36C-090 2 56J19 34,800 33,400 20,800 13.00 11.00 7.70 6.80 3100 2810 2625 3.48 2.32 CH33 -36C-2F 4 G61MPV- 60C-090 2 56J19 35,000 33,400 20,800 13.00 11.00 7.70 6.85 3100_2800 2615 3.50 2.32 CH33- 36C-2F 4 G61MPV- 60C-110 2 56J19 13HPD -042 3.5 TON Air Handlers Air Handlers 39,000 37,200 23,400 13.00 11.00 7.70 6.75 3440 3510 3130 3.10 2.18 3 CB30M -46 (Multi- Position) Factory TXV 39,000 37,400 23,600 13.00 11.00 7.70 6.65 3475 3565 3195 3.08 2.16 3 CB30U -41/46 (Up -Flow) Factory TXV 39,500 36,800 23,000 13.50 11.50 7.70 6.85 3315 3400 3015 3.18 2.24 4 CB31MV -51 (Multi- Position) Factory TXV 41,500 41,000 26,400 13.00 11.00 8.50 7.45 3775 3780 3275 3.18 2.36 CB26UH -042 -R (Up- Flow /Horizontal) Factory RFC (0.082) 41,500 41,000 26,400 13.00 11.50 8.50 7.45 3500 3780 3275 3.18 2.36 5 CB26UH -042 -R (Up -Flow / Horizontal) 2 56J20 NOTE - These are the only approved system match -ups For other matches, contact the Lennox Applications Department. NOTE - Ratings for C33 coils include all cased and uncased coils NOTE - When used with gas furnaces, a dual -fuel control (i.e. FM21) or a control system with dual -fuel capabilities (i.e. Harmony III, LZP -2 or LZP-4) must be used (ordered extra) 1 Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. (7.6 m) of connecting refrigerant lines; Cooling Ratings - 95°F (35 °C) outdoor air temperature and 80 °F (27 °C) db /67 °F (19 °C) wb entering indoor coil air. High Temperature Heating Ratings -47 °F (8 °C) db /43 °F (6 °C) wb outdoor air temperature and 70 °F (21 °C) db entenng indoor coil air Low Temperature Heating Ratings - 17°F (- 8.3 °C) db /15 °F (- 9.4 °C) wb outdoor air temperature and 70 °F (21°C) db entenng indoor coil air 2 Factory Installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped). 3 Blower must be capable of time-off blower delay. Indoor Blower Off Delay Relay (58M81) is recommend for field installation. 4 Blower control must be set for a time-off blower delay 5 Most popular air handler combination. 13HPD -1.5 to 5 Ton Heat Pump / Page 11 1 ARI Standard 210/240 Ratings Capacity - Btuh Efficiency Total Watts COP Expansion High Low HSPF Indoor Unit Model No. Device Cooling Temp. Temp. Cool High Low High Low Heating Heating SEER I EER IV I V Heat Heat Heat Heat 13HPD - 042 3.5 TON Up- Flow_Indoor Coils + Furnaces Up -Flow Coils + Furnaces 40,000 36,400 23,800 14.00 12.00 7.70 7.15 3315 3405 2930 3.14 2.38 C33-48C 4 G61MPV-60C-110 2 56J20 40,000 36,600 23,800 14.00 12.00 7.70 7.10 3325 3380 2950 3.18 2.36 C33-44C 4 G61MPV- 60C-090 2 56J20 40,000 36,600 23,800 14.00 12.00 7.70 7.10 3325 3440 2950 3.12 2.36 C33-48B 4 G6OUHV- 36B-090 2 56J20 40,000 36,600 23,800 14.00 12.00 7.70 7.10 3330 3430 2950 3.12 2.36 C33-48C 4 G61MPV- 60C-090 2 56J20 40,000 36,600 23,600 14.00 12.00 7.70 7.15 3290 3325 2905 3.22 2.38 C33-44C 4 G6OUHV -60C -110 2 56J20 40,000 36,600 23,800 14.00 12.00 7.70 7.15 3310 3355 2930 3.20 2.38 C33 -44C 4 G61MPV -60C -110 2 56J20 40,000 36,800 24,200 13.00 11.50 7.70 7.00 3435 3535 3055 3.06 2.32 C33 -48B 4 G61MPV- 36B-070 2 56J20 40,000 37,000 24,200 13.50 11.50 7.70 7.00 3435 3450 3075 3.14 2.30 C33 -38B 4 G61MPV- 36B-070 2 56J20 40,000 37,000 24,200 13.50 11.50 7.70 7.05 3415 3440 3020 3.16 2.34 C33-43B 4 G61MPV-36B-070 2 56J20 40,000 37,200 24,400 13.00 11.00 7.70 6.95 3490 3475 3110 3.14 2.30 C33 -38B 4 G61MPV -36B -045 2 56J20 40,000 37,200 24,400 13.00 11.00 7.70 7.00 3490 3545 3090 3.08 2.32 C33-48B 4 G61MPV -36B -045 2 56J20 40,500 36,400 23,600 14.00 12.00 7.70 7.15 3290 3380 2905 3.16 2.38 C33-48C 4 G6OUHV -60C -110 2 56J20 40,500 36,600 23,600 14.00 12.00 7.70 720 3300 3315 2900 3.24 2.38 C33 -43C 4 G6OUHV -60C -110 2 56J20 40,500 36,600 23,800 14.00 12.00 7.70 7.15 3310 3300 2950 3.26 2.36 C33-49C 4 G6OUHV -60C-090 2 56J20 40,500 36,600 23,800 14.00 12.00 7.70 7.15 3335 3365 2940 3.18 2.38 C33-43C 4 G61MPV- 60C-090 2 56J20 40,500 36,600 23,800 14.00 12.00 7.70 7.15 3325 3340 2920 3.22 2.38 C33-43C 4 G61MPV -60C -110 2 56J20 40,500 36,600 23,800 14.00 12.00 7.70 720 3310 3360 2900 3.20 2.40 C33-48C 4 G6OUHV -60C -090 2 56J20 40,500 36,600 23,800 14.00 12.00 7.70 7.20 3310 3305 2905 3.24 2.40 C33-44C 4 G6OUHV -60C -090 2 56J20 40,500 36,800 23,800 14.00 12.00 7.70 7.05 3370 3380 3005 320 2.32 C33 -38B 4 G6OUHV- 36B-090 2 56J20 40,500 36,800 23,800 14.00 12.00 7.70 7.10 3375 3390 2970 3.18 2.34 C33-43B 4 G6OUHV- 36B-090 2 56J20 40,500 36,800 24,000 14.00 12.00 7.70 7.20 3370 3340 2940 3.22 2.40 C33-49C 4 G61MPV -60C -090 2 56J20 40,500 37,200 24,400 13.00 11.50 7.70 7.05 3475 3460 3060 3.16 2.34 C33-43B 4 G61MPV -36B -045 2 56J20 41,000 36,600 23,800 14.00 12.00 7.70 7.15 3320 3285 2960 3.26 2.36 C33-43C 4 G6OUHV- 60C-090 2 56J20 41,000 36,600 23,800 14.00 12.00 7.70 7.20 3315 3300 2910 3.26 2.40 C33- 50/60C 4 G6OUHV- 60C-090 2 56J20 41,000 36,800 23,800 14.00 12.00 7.70 7.15 3345 3300 2930 3.26 2.38 C33- 50 /60C 4 G6OUHV -60C -110 2 56J20 41,000 36,800 23,800 14.00 12.00 7.70 7.15 3360 3310 2940 3.26 2.38 C33- 50/60C 4 G61MPV -60C -110 2 56J20 41,000 36,800 23,800 14.00 12.00 7.70 7.20 3345 3300 2905 3.26 2.40 C33-49C 4 G6OUHV -60C -110 2 56J20 41,000 36,800 23,800 14.00 12.00 7.70 7.20 3360 3310 2920 326 2.38 C33-49C 4 G61 MPV -60C -110 2 56J20 41,000 36,800 24,000 14.00 12.00 7.70 7.15 3375 3340 2965 3.22 2.38 C33- 50/60C 4 G61MPV- 60C-090 2 56J20 41,500 36,800 23,800 14.00 12.00 7.70 720 3345 3260 2900 3.30 2.40 C33 -60D 4 G61MPV -60D -135 2 56J20 42,000 36,800 23,800 14.00 12.50 8.20 7.25 3320 3220 2865 3.34 2.44 C33 -60D 4 G6OUHV -60D -135 2 56J20 42,000 36,800 23,800 14.00 12.50 8.20 7.25 3325 3210 2880 3.36 2.42 C33 -62D 4 G6OUHV -60D -135 2 56J20 • 42,000 36,800 24,000 14.00 12.50 7.70 7.15 3350 3250 2965 3.32 2.38 C33 -62D 4 G61MPV -60D -135 2 56J20 42,500 36,600 23,800 14.00 12.50 7.70 7.10 3330 3300 2930 326 2.38 C33-62C 4 G6OUHV- 60C-090 2 56J20 • 42,500 36,800 23,800 14.00 12.50 7.70 7.10 3375 3320 2955 324 2.36 C33 -62C 4 G61MPV -60C -110 2 56J20 42,500 36,800 23,800 14.00 12.50 7.70 7.15 3360 3310 2950 3.26 2.36 C33 -62C 4 G6OUHV -60C -110 2 56J20 42,500 36,800 24,000 14.00 12.50 7.70 7.10 3390 3350 2980 3.22 2.36 C33 -62C 4 G61MPV-60C-090 2 56J20 NOTE - These are the only approved system match -ups. For other matches, contact the Lennox Applications Department NOTE - Ratings for C33 coils include all cased and uncased coils NOTE - When used with gas furnaces, a dual -fuel control (i.e FM21) or a control system with dual -fuel capabilities (i.e Harmony III, LZP -2 or LZP-4) must be used (ordered extra) I Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. (7.6 m) of connecting refngerant lines, Cooling Ratings - 95 °F (35 °C) outdoor air temperature and 80 °F (27 °C) db/67 °F (19 °C) wb entenng indoor coil air High Temperature Heating Ratings - 47 °F (8 °C) db /43 °F (6 °C) wb outdoor air temperature and 70 °F (21°C) db entering indoor coil air. Low Temperature Heating Ratings - 17 °F (- 8.3 °C) db /15 °F (- 9.4 °C) wb outdoor air temperature and 70 °F (21°C) db entenng indoor coil air. 2 Factory Installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (If equipped). • 3 Blower must be capable of time-off blower delay Indoor Blower Off Delay Relay (58M81) is recommend for field installation 4 Blower control must be set for a time-off blower delay. 5 Most popular air handler combination. 13HPD -1.5 to 5 Ton Heat Pump / Page 12 CARIMA IINGS ,: __._.._ __ _ _ ARI Standard 210/240 Ratings Capacity - Btuh Efficiency Total Watts COP Expansion High Low HSPF Indoor Unit Model No. Device • g Cool High Low High Low Cooling Temp. Temp. Heating Heating SEERI EER IV I V Heat Heat Heat Heat 13HPD - 042 3.5 TON Down -Flow- Indoor -Coils + Furnaces Down -Flow Coils + Furnaces 40,500 41,000 26,600 13.00 11.00 7.70 7.05 3565 4135 3500 2.90 2.22 CR33 -48B -F 4 G61MPV- 36B -070 2 56J20 41,000 40,500 26,200 13.50 11.50 7.70 7.15 3460 4025 3395 2.94 226 CR33 -48B -F 4 G6ODFV- 36B-090 2 56J20 41,000 40,500 26,000 14.00 12.00 8.20 7.20 3375 3950 3315 3.00 2.30 CR33 -48C -F 4 G6ODFV- 60C-090 2 56J20 41,000 40,500 26,200 13.50 11.50 7.70 7.15 3435 4015 3380 2.96 2.26 CR33 -48C-F 4 G61MPV- 60C-090 2 56J20 41,000 40,500 26,200 13.50 11.50 7.70 7.20 3435 4000 3370 2.96 2.28 CR33 -48C -F 4 G61MPV -60C -110 2 56J20 41,500 40,500 26,200 14.00 12.00 8.20 7.20 3415 3955 3335 3.00 2.30 CR33 -48C-F 4 G6ODFV -60C -110 2 56J20 42,000 41,000 26,200 14.00 12.00 8.50 7.40 3445 3800 3265 3.16 2.34 CR33- 50 /600-F 4 G61 MPV- 60C-090 2 56J20 42,500 40,500 26,000 14.00 12.50 8.50 7.45 3385 3730 3205 3.18 2.38 CR33- 50 /60C -F 4 G600FV- 60C-090 , 2 56J20 42,500 41,000 26,200 14.00 12.00 8.50 7.45 3425 3740 3230 3.22 2.38 CR33- 50 /60C -F 4 G6ODFV -60C -110 2 56J20 42,500 41,000 26,200 14.00 12.00 8.50 7.45 3415 3725 3220 3.22 2.38 CR33 -60D -F 4 G6ODFV -60D -135 2 56J20 42,500 41,000 26,200 14.00 12.00 8.50 7.40 3440 3780 3260 3.18 2.36 CR33- 50 /60C -F 4 G61MPV -60C -110 2 56J20 42,500 41,000 26,200 14.00 12.00 8.50 7.45 3410 3745 3225 3.20 2.38 CR33 -60D -F 4 G61MPV -60D -135 2 56J20 Horizontal Indoor Coils + Furnaces Horizontal Coils + Furnaces 40,500 40,500 26,000 13.50 11.50 8.20 720 3400 3995 3355 2.98 226 CH23 -41 4 G6OUHV -36B -090 2 56J20 40,500 40,500 25,800 14.00 12.00 8.20 7.20 3345 3960 3305 3.00 2.28 CH23-41 4 G6OUHV- 60C-090 2 56J20 40,500 40,500 26,000 14.00 12.00 8.20 720 3380 3965 3330 3.00 228 CH23 -41 4 G6OUHV -60C -110 2 56J20 41,500 40,500 25,800 14.00 12.00 8.20 7.35 3350 3845 3250 3.08 2.32 CH23 -51 4 G6OUHV- 60C-090 2 56J20 41,500 41,000 26,200 14.00 12.00 8.20 725 3445 3915 3335 3.06 2.30 CH23 -51, 4 G61MPV- 36C-090 2 56J20 41,500 40,500 26,200 14.00 12.00 8.20 7.30 3410 3890 3305 3.06 2.32 CH23 -51 4 G61MPV- 60C-090 2 56J20 42,000 40,500 26,000 14.00 12.00 820 7.35 3385 3855 3275 3.08 2.32 CH23 -51 4 G6OUHV -60C -110 2 56J20 42,000 40,500 26,000 14.00 12.00 8.20 7.30 3400 3865 3290 3.08 2.32 CH23 -51 4 G61MPV -60C -110 2 56J20 42,500 40,500 26,000 14.00 12.00 8.50 7.40 3410 3775 3240 3.14 2.34 CH23 -65 4 G6OUHV -60D -135 2 56J20 42,500 41,000 26,200 14.50 12.00 8.50 7.45 3410 3785 3245 3.18 2.36 CH23 -65 4 G61MPV -60D -135 2 56J20 NOTE - These are the only approved system match -ups. For other matches, contact the Lennox Applications Department NOTE - Ratings for C33 coils include all cased and uncased coils. NOTE - When used with gas furnaces, a dual -fuel control (i.e FM21) or a control system with dual -fuel capabilities (i e. Harmony III, LZP -2 or LZP-4) must be used (ordered extra). 1 Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. (7.6 m) of connecting refrigerant lines; - Cooling Ratings - 95°F (35 °C) outdoor air temperature and 80 °F (27 °C) db/67 °F (19 °C) wb entering indoor coil air. High Temperature Heating Ratings -47 °F (8 °C) db /43 °F (6 °C) wb outdoor air temperature and 70 °F (21 °C) db entering indoor coil air Low Temperature Heating Ratings - 17 °F (- 8.3 °C) db /15 °F (- 9.4 °C) wb outdoor air temperature and 70 °F (21 °C) db entering indoor coil air. 2 Factory Installed expansion valve or RFC on Indoor unit MUST be replaced with valve specified (if equipped). 3 Blower must be capable of time -off blower delay. Indoor Blower Oft Delay Relay (58M81) is recommend for field installation 4 Blower control must be set for a time -off blower delay. 5 Most popular air handler combination 13HPD - 1.5 to 5 Ton Heat Pump / Page 13 1 ARI Standard 210/240 Ratings Capacity - Btuh Efficiency Total Watts COP Expansion Indoor Unit Model No. Device • High Low HSPF Cool High Low High Low Cooling Temp. Temp. Heat Heat Heat Heat Heating Heating SEER I EER IV 13HPD-048 4 TON Air Handlers / Air Handlers 49,000 47,500 30,200 13.00 11.00 8.50 7.504455 3660 3420 3.80 2.58 4 CB27UH -060 (Up -Flow / Horizontal) Factory TXV 49,500 47,500 30,200 13.00 11.00 8.50 7.50 4500 3690 3435 3.78 2.58 4 CB27UH -048 (Up -Flow / Horizontal) Factory TXV 49,500 47,500 30,600 13.00 11.00 7.70 7.40 4455 3775 3525 3.68 2.54 3 CB30M -51 (Multi - Position) Factory TXV 50,000 47,000 30,000 13.50 11.50 7.70 7.50'4350 3650 3400 3.78 2.58 4 CB31MV -51 (Multi - Position) Factory TXV 50,500 47,500 30,600 13.00 11.00 7.70 7.10 4520 4075 3685 3.42 2.44 5 CB26UH-048 (Up -Flow / Factory TXV Up -Flow Indoor Coils + Furnaces Up -Flow Coils + Furnaces 49,000 47,500 30,600 13.00 11.00 7.70 7.10 4450 4050 3675 3.44 2.44 C33- 50/60C 4 G6OUHV -60C -110 2 56J20 49,500 47,500 30,600 13.00 11.00 7.70 7.10 4470 4040 3670 3.44 2.44 C33-49C 4 G61 MPV- 60C-090 2 56J20 49,500 47,500 30,600 13.00 11.00 7.70 7.10 4465 4030 3660 3.46 2.44 C33 -49C 4 G61MPV-60C-110 2 56J20 49,500 47,500 30,400 13.00 11.00 7.70 7.10 4455 4030 3655 3.46 2.44 C33- 50/60C 4 G6OUHV- 60C -090 2 56J20 50,000 47,500 30,400 13.00 11.00 7.70 7.15 4430 3975 3620 3.50 2.46 C33 -49C 4 G6OUHV- 60C-090 2 56J20 50,000 47,000 30,400 13.00 11.00 7.70 7.15 4420 3995 3620 3.44 2.46 C33-49C 4 G6OUHV -60C -110 2 56J20 50,000 47,000 30,000 13.50 11.00 7.70 7.20 4360 3925 3535 3.50 2.48 C33 -60D 4 G6OUHV -60D -135 2 56J20 50,000 47,000 30,400 13.00 11.00 7.70 7.20 4410 3965 3585 3.48 2.48 C33 -60D 4 G61 MPV -60D -135 2 56J20 51,000 47,500 30,400 13.50 11.00 7.70 7.10 4480 4055 3640 3.44 2.44 C33 -62C 4 G6OUHV -60C -110 2 56J20 51,000 47,500 30,600 13.00 11.00 7.70 7.05 4525 4100 3685 3.40 2.44 C33 -62C 4 G61MPV- 60C-090 2 56J20 51,000 47,500 30,600 13.00 11.00 7.70 7.05 4520 4095 3680 3.40 2.44 C33 -62C 4 G61MPV -60C -110 2 56J20 51,500 47,500 30,400 13.50 11.50 7.70 7.10 4480 4035 3625 3.46 2.46 C33 -62C 4 G6OUHV- 60C-090 2 56J20 Down -Flow Indoor Coils + Furnaces Down -Flow Coils + Furnaces 49,000 47,500 30,200 13.00 11.00 7.70 7.50 4400 3685 3440 3.78 2.58 CR33- 50 /60C -F 4 G6ODFV -60C -110 2 56J20 49,000 47,500 30,400 13.00 11.00 7.70 7.40 4450 3760 3510 3.70 2.54 CR33- 50 /60C -F 4 G61 MPV -60C -110 2 56J20 49,000 47,500 30,200 13.00 11.00 7.70 7.50 4395 3680 3435 3.78 2.58 CR33 -60D -F 4 G6ODFV -60D -135 2 56J20 49,000 47,500 30,400 13.00 11.00 7.70 7.50 4395 3705 3455 3.76 2.58 CR33 -60D -F 4 G61MPV -60D -135 2 56J20 49,500 47,500 30,400 13.00 11.00 7.70 7.50 4415 3680 3445 3.78 2.58 CR33- 50 /60C -F 4 G6ODFV- 60C-090 2 56J20 Horizontal Indoor Coils + Furnaces Horizontal Coils + Furnaces 50,000 47,500 30,400 13.00 11.00 7.70 7.15 4460 4020 3625 3.46 2.46 CH33- 50/60C -2F 4 G6OUHV -60C -110 2 56J20 50,000 47,500 30,600 13.00 11.00 7.70 7.10 4505 4065 3670 3.42 2.44 CH33- 50/60C -2F 4 G61 MPV- 60C-090 2 56J20 50,000 47,500 30,600 13.00 11.00 7.70 7.10 4505 4045 3665 3.44 2.44 CH33- 50/60C -2F 4 G61MPV -60C -110 2 56J20 50,000 47,000 30,200 13.50 11.00 7.70 7.20 4360 3925 3550 3.50 2.50 CH33- 60D -2F 4 G6OUHV -60D -135 2 56J20 • 50,000 47,000 30,400 13.00 11.00 7.70 7.15 4410 3965 3585 3.48 2.48 CH33- 60D-2F 4 G61MPV-60D-135 2 56J20 50,500 47,500 30,200 13.50 11.50 7.70 7.65 4365 3530 3355 3.94 2.64 CH23 -68 4 G6OUHV -60D -135 2 56J20 50,500 47,500 30,200 13.50 11.00 7.70 7.60 4420 3570 3400 3.90 2.60 CH23 -68 4 G61MPV -60D -135 2 56J20 50,500 47,500 30,600 13.00 11.00 7.70 7.15 4465 3985 3615 3.50 2.48 CH33- 50 /60C -2F 4 G6OUHV- 60C-090 2 56J20 NOTE - These are the only approved system match -ups. For other matches, contact the Lennox Applications Department NOTE - Ratings for C33 coils include all cased and uncased coils. NOTE - When used with gas furnaces, a dual -fuel control (i.e. FM21) or a control system with dual -fuel capabilities (i.e. Harmony III, LZP -2 or LZP-4) must be used (ordered extra). 1 Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. (7 6 m) of connecting refrigerant lines, Cooling Ratings - 95 °F (35 °C) outdoor air temperature and 80 °F (27 °C) db /67 °F (19 °C) wb entering indoor coil air. High Temperature Heating Ratings -47 °F (8 °C) db /43 °F (6 °C) wb outdoor air temperature and 70 °F (21°C) db entenng indoor coil air Low Temperature Heating Ratings - 17 °F (- 8.3 °C) db /15 °F ( -9 4 °C) wb outdoor air temperature and 70 °F (21°C) db entenng indoor coil air 2 Factory installed expansion valve or RFC on Indoor unit MUST be replaced with valve specified (If equipped). 3 Blower must be capable of time-off blower delay Indoor Blower Off Delay Relay (58M81) is recommend for field installation. 4 Blower control must be set for a time-off blower delay. 6 Most popular air handler combination. r• 13HPD -1.5 to 5 Ton Heat Pump / Page 14 • • 1 ARI Standard 210/240 Ratings Capacity - Btuh Efficiency Total Watts COP Expansion High Low HSPF Indoor Unit Model No. Device Cooling Temp. Temp. Cool High Low High Low g p p Heating Heating SEERI EER IV I V Heat Heat Heat Heat 13HPD-060 ' S TON Air Handlers '. (\ Air Handlers 54,000 55,000 35,400 13.00 11.00 7.70 6.70 4950 4580 3950 3.52 2.62 4 CB27UH -060 (Up -Flow / Horizontal) Factory TXV 56,500 55,000 35,600 13.00 11.50 7.70 7.75 4860 4670 4005 3.46 2.60 4 CB31 MV -51 (Multi-Position) Factory TXV 57,000 55,000 35,600 13.00 11.00 7.70 7.30 5060 4890 4295 3.30 2.42 CB26UH -060 -R (Up- Flow /Horizontal) Factory RFC (0.098) 57,000 55,000 35,600 13.00 11.00 7.70 7.30 5060 4890 4295 3.30 2.42 5 CB26UH -060 -R (Up -Flow / Horizontal) 2 56J20 57,000 55,500 35,800 13.00 11.50 7.70 7.55 4950 4735 4075 3.44 2.58 3 CB30M -65 (Multi - Position) Factory TXV 57,500 55,000 35,800 13.00 11.50 7.70 7.55 4950 4720 4065 3.42 2.58 3 CB30U -65 (Up -Flow) Factory TXV 57,500 55,000 35,600 13.50 11.50 7.70 7.60 4875 4655 4000 3.46 2.60 4 CB31MV -65 (Multi- Position) Factory TXV Up -Flow Indoor Coils + Furnaces Up -Flow Coils + Furnaces 55,000 54,500 35,200 13.00 11.00 7.70 7.35 4950 4895 4220 3.26 2.44 C33 -60D 4 G61MPV -60D -135 2 56J20 55,500 54,500 35,200 13.00 11.00 7.70 7.40 4955 4810 4165 3.32 2.48 033 -600 4 G6OUHV -60D -135 2 56J20 56,000 55,000 35,400 13.00 11.00 7.70 7.15 5040 5020 4370 3.22 2.38 C33 -62C 4 G61MPV- 600-090 2 56J20 56,000 54,500 35,200 13.00 11.00 7.70 7.35 4965 4870 4235 3.28 2.44 C33 -62D 4 G61MPV -60D -135 2 56J20 56,500 54,500 35,400 13.00 11.00 7.70 7.20 5025 4985 4340 320 2.38 C33 -62C 4 G6OUHV -600-110 2 56J20 56,500 55,000 35,400 13.00 11.00 7.70 7.20 5030 4985 4340 3.24 2.38 C33 -62C 4 G61MPV -600-110 2 56J20 56,500 54,500 35,200 13.00 11.00 7.70 7.40 4970 4790 4175 3.34 2.46 C33 -62D 4 G6OUHV -600-135 2 56J20 57,000 54,500 35,400 13.00 11.00 7.70 7.25 5030 4910 4310 3.26 2.40 C33 -62C 4 G6OUHV- 60C-090 2 56J20 Down -Flow Indoor Coils + Furnaces Down -Flow Coils + Furnaces 53,500 54,500 35,200 13.00 11.00 7.70 7.95 4885 4545 3830 3.52 2.70 CR33- 50 /60C -F 4 G600FV- 600-090 2 56.120 54,000 54,500 35,200 13.00 11.00 7.70 8.00 4910 4530 3830 3.52 2.70 CR33 -60D -F 4 G600FV -600-135 2 56J20 Horizontal Indoor Coils + Furnaces Horizontal Coils + Furnaces 55,000 54,500 35,400 13.00 11.00 7.70 7.30 4970 4935 4265 3.24 2.44 CH33- 600-2F 4 G61 MPV -60D -135 2 56J20 55,000 54,500 35,400 13.00 11.00 7.70 7.45 4970 4875 4175 3.28 2.48 CH33- 62D -2F 4 G61MPV -60D -135 2 56J20 55,500 55,000 35,400 13.00 11.00 7.70 7.95 4980 4380 3735 3.68 2.78 CH23 -68 4 G61 MPV -60D -135 2 56J20 55,500 54,500 35,400 13.00 11.00 7.70 7.35 4975 4850 4225 3.30 2.46 CH33-600-2F 4 G6OUHV -60D -135 2 56J20 56,000 54,500 35,400 13.00 11.00 7.70 7.50 4985 4795 4135 3.34 2.50 CH33- 62D -2F 4 G6OUHV -600-135 2 56J20 56,500 55,000 35,600 13.00 11.00 7.70 8.05 4990 4315 3710 3.74 2.80 CH23 -68 4 G6OUHV -60D -135 2 56J20 57,500 55,000 35,600 13.50 11.50 7.70 725 4900 4970 4325 3.24 2.42 CH33- 50/600 -2F 4 G6OUHV -60C -110 2 56J20 58,000 55,000 35,600 13.00 11.50 7.70 7.30 4940 4950 4330 326 2.40 CH33- 50/60C -2F 4 G6OUHV -60C -090 2 56J20 NOTE - These are the only approved system match -ups. For other matches, contact the Lennox Applications Department NOTE - Ratings for C33 cods include all cased and uncased coils. NOTE - When used with gas furnaces, a dual -fuel control (i.e FM21) or a control system with dual -fuel capabilities (i e Harmony III, LZP -2 or LZP-4) must be used (ordered extra) 1 Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. (7 6 m) of connecting refngerant lines, Cooling Ratings - 95 °F (35 °C) outdoor air temperature and 80 °F (27 °C) db167° F (19 °C) wb entenng indoor coil air High Temperature Heating Ratings - 47°F (8 °C) db /43 °F (6 °C) wb outdoor air temperature and 70 °F (21 °C) db entenng indoor coil air. Low Temperature Heating Ratings - 17°F ( -8.3 °C) db /15 °F (- 9.4 °C) wb outdoor air temperature and 70°F (21 °C) db entenng indoor coil air 2 Factory Installed expansion valve or RFC on Indoor unit MUST be replaced with valve specified (if equipped). 3 Blower must be capable of time -off blower delay. Indoor Blower Off Delay Relay (58M81) is recommend for field installation 4 Blower control must be set for a time-off blower delay 5 Most popular air handler combination. _ Sections _ Description of ARI Ratings Added CB26UH -R ratings ARI Ratings Added Up-flow 13HPD -042 ratings back in 13HPD -1.5 to 5 Ton Heat Pump / Page 15 ,nVLLO A, � • • c • ,� • C ® L us REGISTERED QUALITY CERTIFICATION ORES ONLY SYSTEM S MMEN THE COMPLETE SYSTEM IS LISTED MATH AM L II VI VI )i» Visit at www.lennox.com For the e latest st technical information, www.lennoxdavenet.com Contact us at 1- 800 -4- LENNOX NOTE - Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurnng liability Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury Installation and service must be performed by a qualified installer and servicing agency. ©2007 Lennox Industries Inc. . OD GA ( A ' .,-,„, D-,0-0 s ti a - —A4„,%--1,-.50101,3 ` } V ♦ r 1 , t 1� i t y � 7t t�} ' � 7t h � . } I t ,' t •t fF'iC r +' � - ti "4 , ,04 .�fi 1 r � r � i " '' i � l;' �+ ! ` ;,. Y '` j"'S 4 4 / K .�' y .'r'�. 4 . .. .' . !� 1 � i ) f r - I ` , ,r, f r,lra;. � it® . ip��','�r� F ,7 , � 1 1 , ; a : ® , - -zm H. C o. n f o rt ina k er' �k, , t ) I-I- " ` " gi n { r. Air Conditioning & Heat 7^ ' , P r.-odiW - t C 1 ' I. . o- ' t 1 O ■ , . is r-+1 Y- :r (` rT , .- rT a r t P i .,K ' `(` - D' S' r • l f � t` , / � �I i, l F . ' � i 1 � e 4 {`, a '' 1 1 � , j . ,j l (t'^ r� e y61 bi , r ... S {r N t„e 5"ti'.'K c. ."isiof ?t..t_ „Fell -a /^k r + .#r hi 45 tt 4!- .sl'4 � N t � -.�1�'1 A � r� 9 t i DUCT FREE SPLIT SYSTEM — HIGH W Efficient 13 SEER Air Conditioners and 7.7 HSPF Heat Pumps 3 /4 THRU 3 TONS Air Conditioners • TS Compressor technology for enhanced efficiency in Outdoor Section Size Dimensions 2, 2'/2, & 3 ton models Indoor Section (tons) W x H x D (in) • Rotary compressors in 3 /4, 1, & 1 ton models DFC2A309J1A 3 /4 28 x 2134 x 10 • "Air Care" advanced purifying technology DFF2AHO9J1A 3 /4 32 x 1014 x 7%2 • Wireless remote sensor for enhanced functionality DFC2A312J1A 1 35716 x 25 x 12 • Programmable for 3 time /temperature settings in DFF2AH12J1A 1 32%2 x 10344 x 7%2 24 - hour period • 30 VDC ( - 1 ton) Indoor units for better safety and DFC2A318K1A 1' /z 43 /,s x 25 x 12 • savings on installation costs DFF2AH18J1A 1'/2 42Y2 x 11% x 7 • Factory charged with R -22 refrigerant DFC2A324K1A 2 433/46 x 25 x 12 • 1 year No Hassle replacement limited warranty DFF2AH24K1A 2 4236 x 11 /8 X 7%2 • 5 year limited compressor, 5 year limited coil and parts DFC2A330K1A 2 4478 x 253/46 x 15 warranties DFF2AH30K1A 21/2 5478 x 12 x 9 '"';,r- '''' *. .P "'; ,''. 1 4 7 r?.t:: '/':..,..:, ' ., ,1 DFC2A336K1A 3 44 x 25 x 15 +"'i'' s DFF2AH36K1A 3 54% x 12 /s x 9 ,., _'- -r. , T; I 3 , t l DFC2A318J2A* 2 x 3 /4 13 79 ,4 e,-c.:4' �a' y 35/,6x50 /3zx12/3z '_ 1 ..t f : • , �: „'s' " '` 'I DFF2AHO9J1A* 3 /4 32%2 x 1014 x 7 4. DFC2A324J2A* 2 x 1 35%6 x 50 x 12 I. - - • — ' I ---- -- . ' ti DFF2AH12J1A* 1 32 x 10344 x 7 - " Dual Zone Model _ • ,r- - - - _ _ - - - , j j 0 ' = i Heat Pumps s- ¢` r 4 : Outdoor Section Size Dimensions I _ . x t ° ` ' I ~ { ' Indoor Section (tons) W x H x D (in) ,r `' ' •• t = t r 111 DFC2H309J1A 3 /4 28 x 2114 x 10%8 _ � � % ,'':`' DFF2HHO9J1A 3/4 32 x 1014 x 7%2 : 1 { - r . )I.' ' DFC2H312J1A 1 357,6 x 25 x 12 - � „ _ s., r - •�..., . E` - ;•=-f _ '' DFF2HH12J1A 1 32%2 x 1014 x 7%2 -', DFC2H318K1A 11/2 433/46 x 25 x 12 1 DFF2HH18J1A 11/2 42342 x 11 x 7%2 DFC2H324K1A 2 433/4sx 253/46 x 12%2 DFF2HH24K1A 2 42Y2 x 11% x 7%2 ; �;� �• ;- D FC2H330K1A 2'/2 4478 x 25 x 15 FERF0RMA110E C — uasa PERFORMA L ® DFF2HH30K1A 2'/2 5478 x 12 x 9 C ERTIFIED C ERTIFIED .. ARM.") a e.t.a now; DFC2H336K1A 3 4478 x 25 x 15 1...8., . ., H.. NW. WM, w Case - Rated In accordance with ARI Standard 210 and/ DFF2HH36K1A 3 54/e x 12 x 9 or 240 Certification applies only when used with proper components as listed weh ARI. DFC2H318J2A* 2 x 3 /4 35716 x 50 x 12 DFF2HHO9J1A* 3 /4 32 x 1034 x 7 DFC2H324J2A* 2 x 1 353/46 x 50 x 12'%2 ' � - DFF2HH12J1A* 1 32%2 x 1034 x 7%2 -?NO s'iya Q @S Lt t',; * Dual Zone Model . PLACEME , P K 4j enlY certificate 1O' d Spedficatcons subject to change without notice -- - -- — - - - - -421 41 9500 -03 Jan 2007 �. , a 5 u+ v sw" ray a i'a ks,- Mkt r ka :� zPr:l �v- rs� ; �t�, I �r^•,.�.�"�. ..*T.z.�'. P.t V�• �••, . �x q�., -,,, .. __� -� t IP.RODUCT�lSPECIFICATIONS " �1=:" : - IDuct;'Free.S�p�lt 4ystem =tHigh�W46ik2 fH' Required CLEARANCES, Outdoor ABOVE (min.) - 2' (0.6m) •1 I LEFT (min.) k-, 6" (0.15m) y REAR (min.) k . ,.,. ,,..›, -, - ,.:,-',-,_:;ii, -'''' .-,,,?-,,i ,:-:...;,., . .. - --4. ;;;,.i., FRONT (min.) ' , }, RIGHT min. 2' (0.6m) 7� ( ) 2' (0.6m) Required CLEARANCES, Indoor ABOVE (min.) 6" (0.15m) ' S i •, LEFT (min.) ‘ • RIGHT (min.) 8" (0.2m) ... ' 8" (0.2m) o ' z ' ..... =y I BELOW 6' — 8'3" (1.8m — 2.5m) 2 - - _ . _ _Specifications subject to change without notice. _. 421 41.9500_03 pRODUCT:SPEC_IFICOIONS �{.'•' : _ •,' '. 1DuctuFi eeSSplit S Imo Waft IDFS2A /,H', IDFF2'' a :. £1 i:a ?.f_ ' s. ,f.'. t , o,i.,»,:isl',.:_.. _ • :. ...,'&h'Li. 4 ' -1' �. _. I,' -. , + .1 ...s.1 'loot c i' , .... . Outdoor Model Size 09J1A 12J1A \18K1A 4K1A 30K1A 36K1A 18J2A 24J2A • Indoor Model Size 09J1A 12J1A 18J1A 24K1A 30K1A 36K1A 2 x 2 x 09J1A 12J1A . 4 - �, I *tr. f IAI y .. ,., h _' ` '+k +a, : I'': . .'j:'0 te l: Y� ����;� ,_:,,. , �,c'�, ;' �' �' �P; HYSICAL�DA�TA • Air��onditiorier•�� "t '. , , ,'��� „ , �, Cooling Capacity (BTU/hr) 9,000 11,600 19;000 22,800 29,000 33,000 , 0 2 x 9,000 11,600 SEER 13.0 13.0 13.0 13.0 14.0 13.0 13.0 13.0 Moisture Removal (pints /hr) 2.6 4.5 5.3 5.0 7.0 8.0 2 x 2.6 2 x 4.5 Indoor Fan CFM (High speed) 350 400 670 726 860 860 2 x 350 2 x 400 Indoor Sound Rating 2 x 2 x 55 - 45 60 - 48 62 - 50 64 - 50 65 - 53 65 - 53 (dBA High - dBA Low) 55 -45 60 -48 Outoor Sound Rating (dBA) 68 72 74 76 76 76 74 76 Liquid Line Connection Size (in.) 1/4 1/4 3/8 3/8 3/8 3/8 2 x 1/4 2 x 1/4 Vapor Line Connection Size (in.) 1/2 1/2 5/8 5/8 3/4 3/4 2 x 1/2 2 x 1/2 Maximum Vertical Separation (ft.) 30 30 30 65 65 65 30 30 Indoor Higher than Outdoor Maximum Vertical Separation (ft.) 30 30 30 75 75 75 30 30 Indoor Lower than Outdoor Maximum Line -set Length (ft.) 50 50 50 130 130 130 50 50 Factory Charge R -22 (lbs.) * 2.7 3.1 4.1 4.2 6.06 5.9 2 x 2.7 2 x 3.1 * Units are factory charged for 25' of line set. Add or remove 0.3 oz. of charge per foot if line set length is different. Net Weight, Outdoor (lbs.) 73 114 136 187 198 198 136 228 Net Weight, Indoor (lbs.) 19 19 27.5 27.5 51 51 2 x 19 2 x 19 ; pl: i °_ ." , n O'UITD:QO TR1'C I ODA?FA '` Ay.. inditiane'r' ' ":�' "¢ r t • Required Supply Voltage 115 -1 -60 AC I 208/230 -1 -60 AC I 115 -1 -60 AC Control Voltage 30 VDC 24 VAC Minimum Circuit Ampacity - 9.0 11.6 10.7 11.0 13.7 17.7 19.8 24.6 MCA (amps) Maximum OverCurrent 15 20 20 20 20 30 25 30 Protective device - MOCP (amps) Compressor RLA (Rated Load Amps) 6.1 7.6 6.5 8.6 10.0 . 12.9 7.2 9.3 LRA (Locked Rotor Amps) 42 58 42 60 76 73 42 58 Fan Motor Amps 0.90 1.00 0.88 0.87 0.94 0.94 1.00 1.00 t h.' u ' ;.. : .'''''' r m `I itibb;R• EI t'CTRICALiDATAMAikodliditlorliii '% . Required Supply Voltage 30 DC 1 208/230 -1 -60 AC 30 DC 1 Control Voltage 30 VDC 24 VAC FLA (Full Load Amps) 1.8 1.8 2.4 0.6 0.6 0.6 2 x 1.8 2 x 1.8 Minimum Circuit Ampacity - MCA (amps) N/A 1 N/A 1 N/A 1 0.46 0.55 0.55 N/A 1 N/A 1 Maximum OverCurrent N/A 1 N/A 1 N/A 1 15 2 15 2 15 2 N/A 1 N/A 1 Protective device - MOCP (amps) 1. 30VDC is generated by the outdoor unit and delivered through low voltage wiring to power the indoor unit. Separate disconnect or over - current protection device not required at indoor unit. 2. If indoor unit is powered from outdoor terminal block, the MOCP for the outdoor unit covers both units. 421 41 9500 03 - Specifications subject to change without notice. - 3 • `;o-. a++rt'.va:' +nc• xm sa- -s4-� a , Y le- w"-:: Tr_ 6 1 :77 n,,,,- - apu,. ,,,, � crrrs+k,x- xz -a mri.7%mor ; p: • ■•xa*K•'„ '1'14,M3',1., !PRODUCT , SPECIFICATIONS - ' • ;- . • Duct Free -Split System -;High Walk ;DFS2A/H; /,H .u.•w.,,..,,.t,.'i.-4cr: ✓'444:4 i:.i 4!R .ga.7,i.,... ,..:; �"�' r.,, K•, :a atrn...,....r2•::n:.1 a::14.e..:.v1 .w. u.: / 11 .e 6.4e a4 t' J2' ., .....b. • Outdoor Model Size 09J1A 12J1A 18K1A 24K1A 30K1A 36K1A 18J2A 24J2A • Indoor Model Size 09J1A 12J1A 18J1A 24K1A 30K1A 36K1A 2 x 2 x . 09J1A 12J1A %'.� .. e #' ; ?: 3 . -4,Y,. iP; HYSI CCAL,DAIiA`:_aHe'ataPaum:..' xL o-� .'_; - . . .. .,, x„„01 Cooling Capacity (BTU /hr) 9;000 11,600 19,000 22;800 29,000 33;000 2 x 9,,0000 0 11,600 SEER 13.0 13.0 13.0 13.0 14.0 13.0 13.0 13.0 Heating Capacity (BTU/hr) 8,600 11,800 18,300 22,600 28,000 32,000 2 0 2 x 8,600 11,800 HSPF 7.7 7.7 7.7 7.7 8.4 8.4 7.7 7.7 Moisture Removal (pints/hr) 2.6 4.5 5.3 5.0 7.0 8.0 2 x 2.6 2 x 4.5 Indoor Fan CFM (High speed) 350 400 670 726 860 860 2 x 350 2 x 400 Indoor Sound Rating 2 x 2 x 55 - 45 60 - 48 62 - 50 64 - 50 65 - 53 65 - 53 (dBA High - dBA Low) 55 -45 60 -48 Outoor Sound Rating (dBA) 68 72 74 76 76 76 74 76 Liquid Line Connection Size (in.) 1/4 1/4 3/8 3/8 3/8 3/8 ' 2 x 1/4 2 x 1/4 Vapor Line Connection Size (in.) 1/2 1/2 5/8 5/8 3/4 3/4 2 x 1/2 2 x 1/2 Maximum Vertical Separation (ft.) 30 30 30 65 65 65 30 30 Indoor Higher than Outdoor Maximum Vertical Separation (ft.) 30 30 30 75 75 75 30 30 Indoor Lower than Outdoor Maximum Line -set Length (ft.) 50 50 50 130 130 130 50 50 Factory Charge R -22 (lbs.) * 2.7 3.1 4.1 4.2 6.06 5.9 2 x 2.7 2 x 3.1 * Units are factory charged for 25' of line set. Add or remove 0.3 oz. of charge per foot if line set length is different. Net Weight, Outdoor (lbs.) 73 114 136 187 198 198 136 228 Net Weight, Indoor (lbs.) _ 19 27.5 27.5 51 51 2 x 19 2 x 19 :,�� ^r � ,�,e� - �r- �', 7�•, - +, :- �.:,�- _�;..:p :w , '"a�fa : -�. ,;,has•. 5 ,Z AI OOCi00I .sEUEPO L.16, *i.. Heati Puirwp,�,: ,:i, �. : F �,,.., 0 Required Supply Voltage 115 -1 -60 AC I 208/230 -1 -60 AC I 115 -1 -60 AC Control Voltage 30 VDC 24 VAC Minimum Circuit Ampacity - 9.0 11.6 10.7 11.0 13.7 17.7 19.8 24.6 MCA (amps) Maximum OverCurrent 15 20 20 20 20 30 25 30 Protective device - MOCP (amps) Compressor RLA (Rated Load Amps) 6.1 7.6 6.5 8.6 10.0 12.9 7.2 9.3 LRA (Locked Rotor Amps) 42 58 42 60 76 73 42 58 Fan Motor Amps 0.90 1.00 0.88 0.87 0.94 0.94 1.00 1.00 ; y '`' - 4 `; �INDO",' 0 EL']E "CTgRI.0:1 . ; 434 Pum 'r � r +; ,'� A � � - ..�.. - ., � � • . �., .� _ , , . , , r_, �.., eat -1 ,�,- P�a��,:� �, � �: _,�;;� •f.�:���� Required Supply Voltage 30 DC 1 208/230 -1 -60 AC I 30 DC 1 Control Voltage 30 VDC 24 VAC FLA (Full Load Amps) 1.8 1.8 2.4 0.6 0.6 ' 0.6 2 x 1.8 2 x 1.8 Minimum Circuit Ampacity - N/A 1 N/A 1 N/A 1 0.46 0.55 0.55 N/A 1 N/A 1 MCA (amps) Maximum OverCurrent N/A 1 N/A 1 N/A 1 15 2 15 2 15 2 N/A 1 N/A 1 Protective device - MOCP (amps) 1. 30VDC is generated by the outdoor unit and delivered through low voltage wiring to power the indoor unit. Separate disconnect or over - current protection device not required at indoor unit. 2. If indoor unit is powered from outdoor terminal block, the MOCP for the outdoor unit covers both units. 4 - - - - - - - -- Specifications subject to change without notice -- - -421-41-9500-03-- • ^ . ^ . ' � ( ^ � ' * � r � ' ' �� ; �'�;����'� —� �'�� �����` .��� '� ' +`' ` ^� . Used On • Part Number Description Model Size NADAO01OK Condensate Pump 9, 12, 2 x 9, 2 x 12 • NAOAOO2OK Condensate Pump 1B. 24 NADA003OK Condensate Pump 30, 36 NADAOO1LA Low Ambient Kit * ALL NADAOO1OH Crankcase Heater (1 20V) 8, 12, 2 x 9, 2 x 12 NADAOO2CH Crankcase Heater (240V) 18, 24, 30, 36 1173540 Isolation Relay (120V)* Q. 12, 2 x Q. 2x 12 1174662 Isolation Relay (24OV)° 18, 24, 30, 36 NAOAOO1TVV Wired Control ALL *When Low Ambient Kit is used with Heat Pump, additional Isolation Relay is required. 11,R0,D.UCT SPECIFICATIONS - ' Du0Fre&SplIt'S,ystem - 4High,WelI::DFS2A'H,1DFF2A /H l '�� EIS' PLIT �S3IFSTEM�MO. D. EL�INUMBERyID,EN1�tIFICA7ilO;N� 'GUIDE.= = +�0'UTD.O "O_,R� ".,.,4 DFC 2 A 3 09 J 1 A 1 DFC = Duct Free Condenser 2 = R -22 4 = Environmentally Sound R -410A REFRIGERANT A = Air Conditioner H = Heat Pump TYPE 3 = 13 4 = 14 NAMEPLATE SEER 09 = 9,000 BTUH = 3 /4 ton 12 = 12,000 BTUH = 1 ton 18 = 18,000 BTUH = 11/2 tons 24 = 24,000 BTUH = 2 tons 30 = 30,000 BTUH = 21/2 tons 36 = 36,000 BTUH = 3 tons NOMINAL CAPACITY J = 115 -1 -60 K = 208/230 -1 -60 SUPPLY VOLTAGE 1 = Single Zone 2 = Dual Zone 3 = Tri Zone • SALES CODE / FEATURES Sales Code Engineering Revision 4.'. D,U0T, F,„070E SPLITS STEMIIMO;DEL)N,U,MB'EiR ID, ENTIFI,cAinON'IGU oND:000.-. DFF 2 A H 09 J 1 A 1 DFC = Duct Free Fan Coil 2 = R -22 4 = Environmentally Sound R -410A REFRIGERANT A = Air Conditioner H = Heat Pump TYPE H = High Wall U= Under Ceiling C = Cassette APPLICATION 09 = 9,000 BTUH = 3 /4 ton 12 = 12,000 BTUH = 1 ton 18 = 18,000 BTUH = 11/2 tons • 24 = 24,000 BTUH = 2 tons 30 = 30,000 BTUH = 21/2 tons . 36 = 36,000 BTUH = 3 tons NOMINAL CAPACITY J = 115 -1 -60 K = 208/230 -1 -60 SUPPLY VOLTAGE 1 = Single Zone 2 = Dual Zone - 3 = Tri Zone SALES CODE / FEATURES Sales Code Engineering Revision International Comfort Products, LLC Lewisburg, Tennessee 37091 www.GoComfortmaker.com - _ _6_ _ _ _ _ . speaecatlons.sublect to.change without notice. _ . _421._41.9500_03 _ _ . - _ 0 0 — 1 -6 a v �1' _, LGREENHECK Model CFSD -211 Ul Application and Design Corridor Ceiling FIRE SMOKE DAMPER Model CFSD -211 is a combination fire smoke damper that is UL Steel 3V Blades classified to protect corridor ceiling penetrations as required by the UL 555S Leakage Class Uniform Building Code. This model's operational ratings of 2,000 fpm (10.2 m/s) and 4 in. wg (1.0 kPa) far exceed the air flows and Model CFSD -211 meets the requirements for corridor pressure differences normally encountered when installed above ceiling dampers, smoke dampers and combination grilles or diffusers in corridor ceilings - providing an extra measure fire/smoke dampers established by: of safety. CFSD -211 is rated for airflow and leakage in either direction and can be used in vertical or horizontal installations. National Fire Protection Association NFPA Standards 80, 90A, 92A, 92B, 101 8105 Ratings ICBO Uniform Building Codes UL 555 Fire Resistance Rating IBC International Building Codes Fire Rating: 1 hour New York City (MEA Listing #260 -91 -M) Dynamic Closure Rating: Actual limits are size dependent CSFM California State Fire Marshal Maximum Velocity: 2000 fpm (10.2m/s) Listing #: 3230 - 0981:105, 3225 - 0981:106 Maximum Pressure: 4 in. wg (1.0 kPa) UL 555$ Leakage Rating Leakage Class: I Operational Rating: Limits are actuator dependent Maximum Velocity: 2000 fpm (10.2 m/s) "UL CLASSIFIED (see complete marking on Maximum Pressure: 4 in. wg (1.0 kPa) product)" Maximum Temperature: 350 °F (177 °C) - depending upon "UL CLASSIFIED to Canadian safety standards the actuator (see complete marking on product)" Standard Construction Standard 555 & 555S (Listing #R13317) Frame: 5 in. x 1 in. (127mm x 25mm) galvanized steel hat channel with reinforced corners. A low profile C ® US head and sill are used on sizes less than 17 in. (432mm) high to Greenheck Fan Corporation certifies that the maximize free area and pmCC1 model CFSD -211 shown herein is licensed to ' performance. CERTIFIED bear the AMCA Seal. The ratings shown are Blades: 16 ga. (1.5mm) galvanized steel, RRTIRGS based on tests and procedures performed reinforced with 3 longitudinal in accordance with AMCA Publication 511 structurally designed vee's. / RIR and comply with the requirements of the Seals: Extruded silicone rubber blade oree...Cr AMCA Certified Ratings Programs. The seals. Flexible stainless steel :a AMCA Certified Ratings Seal applies to air jamb seals. movenEi performance ratings only. ano contact Linkage: Concealed in jamb. nssocunon.inc. Closure Device: UL listed 165 °F (74 °C) RRL " " " "- " "'•' -° . Axles: Y in. (13mm) dia. plated steel. Bearings: Bronze sleeve type. Size Limitations (see page 3 for specific limitations) Minimum Size: x• w• Configuration 1: 12 in. W x 12 in. H (305mm x 305mm) .....-....7........__.„ Configuration 2: 8 in. W x 6 in. H (203mm W x 152mm H) Configuration 3: 8 in. W x 6 in. H °IL: -- (203mm W x 152mm H) ` 11 1.11 II Maximum Size: 24 in. W x 24 in. H (610mm x 610mm) Optional Features: lam. • Stainless steel bearings •. • RRUOCI (Open Closed Indication switches) • 165 °F (74 °C), 212°F (100 °C), 250 °F (121°C), 350 °F (177 °C) RRL's . available • TOR (remote override of 165 °F (74 °C) or 212°F (100 °C) closure. Allows damper to perform smoke management functions during a fire emergency.) y • Electric or pneumatic actuators . •w & H dimensions furnished approximately 1/4 in. (6mm) • POC retaining angles undersize. (Add sleeve thickness for overall sleeved damper • Momentary test switch dimension) Right hand drive is shown. Left hand drive is available • Sealed transition and sleeve - upon request. PRESSURE DROP DATA CFSD -211 This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of .075 lb /ft' (1.201 kg/m Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. 5D i I- 6D 1=> n u u 5D i n r c D 4 (W) (H) 3.14 u >. I I I rC 7 1 - AMCA 5.2 Pressure Drop CFSD -211 5D Il r 11> --•=•- -e -.- Figure 5.2 U L VELOCITY VS. PRESSURE DROP 1 0.s 0.8 - 12x12 0.7 - 24x24 ' o.s 0.5 • - 36x36 C7 0.4 • ' 12x48 - - - - 48x12 N 0.3 • W Z C.) 0.2 . Z a O IX_ 0.1 1 0.09 W 0.08 CC 0.07 N 0.06 U) 0.05 / • W tY 0.04 0.03 0.02 t , , 2 3 4 5 6 7 8 9 20 30 40 50 100 FACE VELOCITY - FEET /MINUTE AMCA FIG. 5.2 * This size is based on multi - section unit. 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 in. x48 in. (305mm x 1219mm) 48 in. x 12 in. (1219mm x 305mm) Pressure Drop eloaty (fpm) Y Velocity (1pm ) Pressure Drop Vdo ' Pressure Drop Pressure Drop V elocity (fpm) Pressure Drop Vdolity ball (in. wg) (m. wg) city (�) (m. wgf (n. wg) (n. wm 500 0.04 500 0.02 500 0.01 500 0.01 500 0.03 1000 0.14 1000 0.07 1000 0.04 1000 0.06 1000 0.10 1500 0.31 1500 0.16 1500 0.09 1500 0.13 1500 0.23 2000 0.55 2000 0.29 2000 0.16 2000 0.23 2000 0.41 2500 0.86 2500 0.45 2500 0.25 2500 0.36 2500 0.63 3000 1.24 3000 0.65 3000 0.36 3000 0.52 3000 0.91 3500 1.69 3500 0.89 3500 0.49 3500 0.70 3500 1.24 4000 2.20 4000 1.16 4000 0.64 4000 0.92 4000 1.62 AMCA Greenheck Fan Corporation certifies that the COWED model CFSD-211 shown herein is licensed to bear ootmot the AMCA Seal. The ratings shown are based on • tests and procedures performed in accordance - with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Pro- grams. The AMCA Certified Ratings Seal applies to _. _ - air performance ratings only. I. AMCA 5.3 Pressure Drop CFSD -211 r 5D 1. 6D ► 0 0 f II> --•=.,-- Figure 5.3 o u VELOCITY VS. PRESSURE DROP ° 0.e - 12x12 0.6 0.6 - 24x24 < 0.5 - 36x36 O 0.4 12x48 • 0.3 ---- 48x12 u) = 0.2 V Z 0 0 0 . 08 / '' Y ' IX 0.07 O 0 06 W 0.05 cc • 0.04 - /; fn 0 03 C/9 W cc 0.02 a 0.01 '/ 2 3 4 5 6 7 8 9 20 30 40 50 60 708090 100 10 FACE VELOCITY - FEET /MINUTE AMCA FIG. 5.3 ' This size is based on multi - section unit. 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x36 in. (914mm x 914mm) 12 in. x48 in. (305mm x 1219mm) 48 in. x 12 in. (1219mm x 305mm) Pressure Drop Pressure Drop Pressure Drop Pressure Drop Pressure Drop velocity Ifim) (m. wg) Velocity (ham) [in. wg) Velocity (fpm) (m. wg) Velocity (fpm) (in. wg) Velocity (fpm) (n. wg) 500 0.02 500 0.01 500 0.01 500 0.01 500 0.02 1000 0.09 1000 0.04 1000 0.03 1000 0.04 1000 0.07 1500 0.20 1500 0.09 1500 0.06 1500 0.10 1500 0.16 2000 0.36 2000 0.16 2000 0.11 2000 0.17 2000 0.29 2500 0.56 2500 0.25 2500 0.17 2500 0.27 2500 0.45 3000 0.81 3000 0.35 3000 0.24 3000 0.39 3000 0.64 3500 1.10 3500 0.48 3500 0.33 3500 0.53 3500 0.88 • 4000 1.44 4000 0.63 4000 0.42 4000 0.70 4000 1.14 Greenheck Fan Corporation certifies that the • °mca model CFSD -211 shown herein is licensed to bear CFRIW aanno the AMCA Seal. The ratings shown are based on . tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Pro- m� gra The AMCA Certified Ratings Seal applies to • air performance ratings only. - AMCA 5.5 Pressure Drop CFSD -211 1 _c_ :_ J VELOCITY VS. PRESSURE DROP 1 0.9 - 12x12 0.8 0.7 I. - 24x24 0.6 - 36x36 o.s O oa 12x48 ---- 48x12 • cn 0.3 W 2 : z 0.2 / D. O 01 ,,, /./":.: 0 0.09 W 008 Ce 0.07 W 0.06 N 0.05 W /-. lY 0.04 a 0.03 0.02 2 3 4 5 6 7 8 9 20 30 40 50 60 708090 100 FACE VELOCITY - FEET /MINUTE AMCA FIG. 5.5 This size is based on multi - section unit. 12 in. x 12 in. (305mm x 305mm) 24 m. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 12 m x48 in (305mm x 1219mm) 48 in x 12 in. (1219mm x 305mm) Pressure Drop Pressure Drop Pressure Drop Pressure Drop Pressure Drop Velocity(fpm) ( in.wg) Velocity(fpm) (in.wg) Velocity (fpm) ( in.wg) Velocity ((pm) (in.wg) Veloaty(ipm) ( in. w9) 500 0.06 500 0.03 500 0.03 500 0.03 500 0.04 1000 0.22 1000 0.14 1000 0.12 1000 013 1000 0.17 1500 0.50 1500 0.31 1500 0.26 1500 0.30 1500 0.38 2000 0.89 2000 0.54 2000 0.46 2000 0.53 2000 0.67 2500 1.39 2500 0.85 2500 0.73 2500 0.83 2500 1.04 3000 2.00 3000 1.22 3000 1.05 3000 1.19 3000 1.50 3500 272 3500 1.66 3500 1.42 3500 1.62 3500 205 4000 3.55 4000 2.17 4000 1.86 4000 2.11 4000 2.67 - amca Greenheck Fan Corporation certifies that the CERTIFIED model CFSD -211 shown herein is licensed to bear nannof the AMCA Seal. The ratings shown are based on • tests and procedures performed in accordance '. with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Pro- grams. The AMCA Certified Ratings Seal applies to le. COMM T . - __.... air performance ratings only. Configurations Space Envelopes CFSD -211 is available in 3 different configurations to accommodate a variety of installation and access requirements. Drawings below illustrate these different configurations and their associated dimensions. Configuration #1 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal Only) Accessible Through The Grille Honeywell Actuator Space ML -4XXX Series H •I Envelopes MS4209 Series in. (mm) I X Dimension 6.875 (175) — } } } — e I Minimum Width 12 (305) Sleeve ' r Le ngth Minimum Height 12 (305) I o A ` Sleeve Length = Depth of Grille (or Register) / Je -e. // / / /// .... `�∎ . + X (Actuator. see table above) Fire Rated R + 5 in. [127mm] (Damper Width) Ceiling `Gnlle (by others) + 1.25 in. [31.8mm] (for duct connection) (round up to nearest length: 14 in., 16 in., 18 in., or 21 in. [356mm, 406mm, 457mm, or 533mm] Sleeve Gauge = 16 Ga. (1.5mm) or 20 Ga. (1 mm) Configuration #2 - Fire Rated Ceiling Is The Finished Ceiling: Actuator (Internal or External) Accessible Above Finished Ceiling Configuration #2 is for applications where the fire rated r H - 1 ceiling is the finished ceiling but where access to the damper actuator is available from above the finished ceiling. Actuators f can be mounted internally or externally. Clearance must be A maintained between damper and grille for proper operation. Sl eeve Length 1=== 1 All dimensions shown are in inches (mm). � i � air <M;n. 'A' Dimension Minimum ` Standard Sleeve Length Fire Rated R\ When OCI, RRL TOR, Ceding Grille (by others) , or 10 1/4 21 H dimension less than 10 in. (260) (533) (254mm) Minimum Size Internal : 12 in. x 12 in. (305mm x 305mm) All other dampers 61/4 (159) 16 (406) Configuration #3 - Fire Rated Ceiling Is Above The Finished Ceiling: Actuator (Internal or External) Accessible Through Finished Ceiling r H 1 — — C 1 Configuration #3 is for applications where the fire rated ceiling is above the finished ceiling. Actuators can be mounted internally or externally. _ r - - - -- - - - -- -- -I I Sleeve All dimensions shown are in inches (mm). Fire Rated ; Length Ceiling ; o ; J 'A' Dimension Minimum A Standard Sleeve Length 1 When OCI, RRL, or TOR, 101/4 21 H dimension less than 10 in. (260) (533) (254mm) Finished Ceiling Below 1 All other dampers 61 /4 (159) 16 (406) Minimum Size Internal : 12 in. x 12 in. (305mm x 305mm) Specifications CFSD-21 1 Corridor Ceiling Fire Smoke Dampers meeting the following mounting damper vertically (with blades running horizontal) • specifications shall be furnished and installed where shown on or horizontally. plans and /or as described in schedules. Dampers shall meet the requirements of the latest edition of NFPA 80, 90A, 92A, 92B, The Damper Manufacturers submittal data shall certify all air 101 & 105. performance pressure drop data is licensed in accordance with the AMCA Certified Ratings Program for Test Figures 5.2, 5.3 and 5.5. Dampers shall be tested, rated and labeled in accordance with Damper air performance data shall be developed in accordance the latest edition of UL Standards 555 and 555S. Dampers shall be with the latest edition of AMCA Standard 500 -D. Dampers shall be classified by UL under the "Corridor Damper" listing with a UL 555 labeled with the AMCA Air Performance Seal. fire rating of 1 hour. Each damper shall be equipped with a heat responsive device which has been tested and approved for use Dampers shall be listed by the California State Fire Marshal. with the damper assembly in accordance with UL 555. The heat Dampers shall be listed by the New York City Department of responsive device shall have a temperature rating of (specifier select Buildings Material and Equipment Acceptance (MEA). one of the following) 165 °F (74 °C), 212 °F (100 °C), 250 °F (121 °C), Damper blades shall be 16 ga. (1.5mm) galvanized steel 3V type or 350 °F (177 °C). Dampers shall be UL labeled for use in dynamic systems. The damper shall have a dynamic closure airflow rating with three longitudinal grooves for reinforcement Blades shall be equal to or greater than the airflow at the damper's installed location completely symmetrical relative to their axle pivot point, presenting and a dynamic closure pressure rating of 4 in. wg (1 kPa). identical resistance to airflow and operation in either direction through the damper (blades that are non - symmetrical relative to Dampers shall have a UL 555S Leakage rating of Class I and a their axle pivot point or utilize blade stops larger than / in. (13mm) temperature rating of 350 °F (177 °C). Dampers shall have a UL 555S are unacceptable). operational airflow rating equal to or greater than the airflow at its Damper frames shall be galvanized steel formed into a structural hat installed location and an operational pressure rating of 4 in. wg (1 kPa). Damper actuators must be factory mounted and qualified channel shape with reinforced corners. Bearings shall be sintered for use with the damper in accordance with UL 555S. Damper bronze sleeve type rotating in extruded holes in the damper frame. actuators shall be (specifier select one of the following) electric type Blade edge seals shall be silicone rubber designed to inflate and for 120 (or 24) volt operation. Manufacturers submittal data shall provide a tight seal against leakage as pressure on either side of the indicate actuator space requirements around the damper. damper increases. Jamb seals shall be stainless steel compression type. All UL 555 and 555S Dynamic Closure Ratings, Operational Ratings Basis of design is Greenheck Model CFSD -211. and Leakage Ratings shall be qualified for airflow and pressure in either direction through the damper. UL ratings shall allow for GREENHECK Copyright © 2006 Greenheck Fan Corporation CFSD -211 Rev. 7 June 2006 P.O. Box 410 • Schofield, WI 54476.0410 • 715 359.6171 • greenback corn