Loading...
Permit CITY OF TIGARD MECHANICAL PERMIT ° COMMUNITY DEVELOPMENT PERMIT #: MEC2007 -00399 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 DATE ISSUED: 7/6/2007 PARCEL: 2S115AD-05900 ITE ADDRESS: 10627 SW TUALATIN DR ZONING: R -4.5 SUBDIVISION: DOVER LANDING LOT: 042 JURISDICTION: TIG PROJECT: VANDERHEIDEN Project Description: Install furnace and AC. CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: SF UNIT HEATERS: VENT FANS: OCCUPANCY GRP: R3 VENTS W/O APPL: VENT SYSTEMS: STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: 1 DOMES. INCIN: NAT 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: FIRE DAMPERS ?: 30 - 50 HP: REPAIR UNITS: WOODSTOVES: GAS PRESSURE: 50 + HP: FURN < 100K BTU: 1 AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: <= 10000 cfm: OTHER UNITS: > 10000 cfm: GAS OUTLETS: Owner: FEES ANN VANDERHEIDEN Description Date Amount 10627 SW TUALATIN DR TIGARD, OR 97224 [MECH] Permit Fee 7/6/2007 $72.50 [TAX] 8% State Surcha 7/6/2007 $5.80 Total $78.30 Phone: 503- 329 -8168 Contractor: THERMAL FLO 7236 SW DURHAM RD. STE 100 PORTLAND, OR 97224 REQUIRED ITEMS AND REPORTS Contact #: PRI 503- 670 -8343 FAX 503- 620 -1953 Reg #: LIC 151847 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain copies of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By: Permittee Signature: c- Call 503.639.4175 by 7:00 a.m. for inspections that business ddy. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. t, 1 07/06/2007 10:47 5036709064 THERMAL FLO PAGE 01 Mechanical Permit Application FOR OFI. .:1 11SE ONLY City of Tigard „ \, � � A. Permit Nn.M�,6 -u o,� 11111 u 13125 SW Hall Blvd.. Tigard, OR p.M1r. .�� a plan Ravi v. Phone: 503,639.4171 Fax: 503.598.1960 Data/By: Other Permit: TIC ,1 It n Inspection Line: 503.639 JUL 0 6 2001 Date Readykly: Sec ra> e t ter Internet: www.ligard- or.gov ' ' Notified/Metllnd; �� Supplemental Information • TYPE�0 g � y L 7 � �COMMERCIAL'FEE* SCHEDULE - USE�CHECIa.IST El Ncw construction �AdditigislkLe> .l�tlYCWacsm9'�(iS VISION Mechanical permit fees" arc based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ['Demolition ❑ Other: mechanical materials, equipment. labor. overhead. and profit. CATEGORY OP CONSTRUCTION Value: $ RFSIDENTIAL-EQUIPMENT / SYSTEMS PEES* xi I- and 2- family dwelling ❑ Commercial /industrial ❑ Accessory building For special hl formorion use checklist. ❑ Multi-family ❑ Master builder ❑ Other: Description l Qty. Ea, 1 Total JOB SITE INFORMATION AND LOCATION Heating/cooling Job silo address: 1062.7 0 1 up4 � q . (re q uiress 7 Airessitc p ti in lan sho bewin g pump pump �- I 14.00 lt' City / State/ZIP: 5 ho (Z (i •� Furnace 100,000 BTU (ducts /vents) I 14.00 ) 4.w 1 1 ��.� O ►` ` �• / 2....211 Fumacc 100,000+ (3•I'U (ducts/vcnts) 17.90 Suite/bldg. /apt. no.: Project name: Van c .t er 6 ter Gas heat pump 14.00 Cross street /directions to job site Duct work 14.00 Hvdronic hot water system 14.00 Residential boiler (radiator or hydronic) 14..00 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 10.00 Flue/vent for any of above 10.00 Subdivision; Lot no.: - Other: 10.00 _ Tax map /parcel no.: Other fuel appliances _ DESCRIPTION OF WORK Water heater 10.00 i _ / Gas fireplace 10.00 Slf�, i ♦ '' , • j I 'en Flue vent for water heater or gas fireplace 10.00 • Log lighter (gas) 10.00 Wand/pellet stove 10.00 Wood fireplace /insert 10.00 . 0 PROPERTY OWNER ❑ TENANT Other 10.00 10.00 Other: 10.00 T.V.. �n I l Environmental exhaust and ventilation ry Range hood /other kitchen Address: I O(, ,i 50 T �,��-;:• equipment 10.00 City /State/ZIP: t r t4 7 22(1 Clothes dryer exhaust 10.00 Single -duct exhaust (bathrooms, Phone: 013 tax: ( ) - toilet compartments, utility rooms) , _ 6.80 ❑ APPLICANT ❑ CONTACT PERSON Attic/crawlspace fans 10.00 Other: 10,011 Business name: Fula piping _ Contact name: $5.40 for first four; S1.00 for each a dditional Furnace. etc. Address: Gas heat pump City /State/ZIP: Wall/suspended/unit heater Phone; ( ) Fax: • ( ) Water hatter .- Fireplace E -mail: Range CONTRACTOR Barbecue . Business name- Thermal Flo, inc. Clothes dryer (gas) Other: Address: 7236 SW Durham Rd AMECHANIr:A1.PERMITFETV* City / State/ZIP; Portland, OR 97224 Subtotal ZtZ', DO Minimum permit Ice ($72.50) Phone: (503) 670 -8343 Fox: (503) 620 -1953 Plan review (25% of permit ice) • CCBtic.:151847 State surcharge (R %or permit fee) S, SC) /� TOTAL PERMIT e n FEE )5r,30 This permit application expires If a permit Is not obtained within 184. Authorized signature:, days after 1t has been accented as complete. [ name: Brenda Estes - Dale: 7_ t " lee meltccdology get lay Tri•Counly Building Induury Service Board 07406/2007 10:47 5036709064 THERMAL FLO PAGE 03 " Site Plan Prepared by: Aries \1a„ .c -.Q A Date: 4 -s - o} Customer Name:Uc \ X Address: Customer Phone 3z * —'Mb% _ ga.2Zse Property Boundary Line g 1": House 0 X Street CITY OF TIGARD BUILDING DIVISION PERMIT #: MEC2007-00399 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 7/6/2007 Phone: (503) 639 -4171 � Inspection Requests (24 Hrs.): (503) 639 -4175 .. ' ° 'I � .. INSPECTION WORKSHEET FOR DATE: 7/19/2007 TIME: 7:03AM PAGE: 68 SITE ADDRESS: 10627 SW TUALATIN DR CLASS OF WORK: SUBDIVISION: DOVER LANDING LOT #: 042 TYPE OF USE: PROJECT NAME: VANDERHEIDEN DESCRIPTION: Install furnace and AC. OWNER: VANDERHEIDEN, ANN PHONE #: 503329 -8160 CONTRACTOR: THERMAL FLO PHONE #: 503.670 -8343 Inspection Request Scheduled For: Date: 7/19/2007 Pour Time: Code # Inspection Description Confirm # Contact # Message 699 Mechanical final 052225 -01 503-670 -8343 Y Corrections/Comments/Instructions: /1 -27 1 %L ` 4 _ _ .. A/ e ae: ' ----::. i C\e"..' P' .4......r. --- i 1 ... e___._i,r„0- Zi___ ❑ PASS _ ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS FAIL ❑ ALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED r...azz Inspector: Date: / S' a7 Phone #: (503) 718- CITY OF TIGARD BUILDING DIVISION PERMIT #: MEC2007-00399 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 7/6/2007 Phone: (503) 639 -4171 Inspection Requests (24 Hrs.): (503) 639 -4175 INSPECTION WORKSHEET FOR DATE: 8/22/2007 TIME: 7:01AM PAGE: 61 SITE ADDRESS: 10627 SWTUALATIN DR CLASS OF WORK: SUBDIVISION: DOVER LANDING LOT #: 042 TYPE OF USE: PROJECT NAME: VANDERHEIDEN DESCRIPTION: Install furnace and AC. OWNER: VANDERHEIDEN, ANN PHONE #: 5 03 - 329 CONTRACTOR: THERMAL FLC) PHONE #: 503- 670 -8343 Inspection Request Scheduled For: Date: 8/22/2007 Pour Time: Code # Inspection Description Confirm # Contact # Message 699 Mechanical final 054270 -01 503-670.8343 N Corrections /Comments /Instructions: ❑ PASS ❑ PARTIAL APPROVAL ❑ CANCEL O ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: '1 Date: -6? Z —,a > Phone #: (503) 718- Z�-Q- CITY OF TIGARD BUILDING DIVISION PERMIT #: MEC2007 -00399 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 7/6/2007 Phone: (503) 639 -4171 A. Inspection Requests (24 Hrs.): (503) 639 -4175 s 1 111 INSPECTION WORKSHEET FOR DATE: 8/24/2007 TIME: 7:00AM PAGE: 68 SITE ADDRESS: 10627 SWTUALATIN DR CLASS OF WORK: SUBDIVISION: DOVER LANDING LOT #: 042 TYPE OF USE: PROJECT NAME: VANDERHEIDEN DESCRIPTION: Install furnace and AC. OWNER: VANDERHEIDEN, ANN PHONE #: 503.329 -8160 CONTRACTOR: THERMAL FLO PHONE #: 503 670 - 6343 Inspection Request Scheduled For: Date: 8/24/2007 Pour Time: Code # Inspection Description Confirm # Contact # Message 699 Mechanical final 054583 -01 503747 -6252 Y Corrections /Comments /Instructions: PASS ❑ PARTIAL APPROVAL 0 CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: —Z4 Z Phone #: (503) 718- 1_5a