Correspondence / EcF/1 z 2I/ C9/4 i 5 , t • CONSOLIDATED FIRE AND RESCUE i Washington County Fire District No. 1 • City of Beaverton Fire Department �•®•:� Tualatin Fire District mum FIRE MARSHALS OFFICE August 1, 1988 Wyatt Fire Protection. Inc. 9095 S.W. Burnham Tigard, Oregon 97223 Attn: Claton RE: Air -Teq Paint Booth 9806 Tigard Avenue Tigard, Oregon Gentlemen: A fire and life safety plan review was conducted on the above captioned project for compliance with the 1985 editions of the Uniform Building Code (UBC), Uniform Mechanical Code (UMC), and Uniform Fire Code (UFC) as amended by Tualatin Rural Fire Protection District's Ordinance 86 -5. Plans are approved as submitted conditional to the following items: 1. Job Site Inspection: Please contact this office for an appointment to have inspection after completion of job while fitter is still on the job site. Twenty -four hour notification is preferable. 2. Approved Plans on Job Site: One set of approved plans bearing the stamps of the Tigard Building Department and this office must be maintained on the project site throughout all phases of construction and must be made available to building and fire inspectors for reference during required construction inspections. (UBC Sec. 303) 3. Inspections Required: Inspection and approval of construction by a representative of this office is required: (a) prior to the cover of any new framing elements following the installation of all utility runs which will be concealed within wall and partition cavities; (b) upon completion of construction and prior to occupancy of the tenant space. (UBC Sec. 305) SPECIAL NOTICE: DEVIATIONS FROM THE SUBMITTED AND HEREBY CONDITIONALLY APPROVED PLANS DURING THE COURSE OF CONSTRUCTION, EXCLUSIVE OF THOSE NECESSARY TO COMPLY WITH FIRE SAFETY REQUIREMENTS AS LISTED HEREIN, ARE PROHIBITED WITHOUT THE WRITTEN AUTHORIZATION OF THE WASHINGTON COUNTY BUILDING DEPARTMENT AND THIS OFFICE. 4755 S.W. Griffith Drive • P.O. Box 4755 • Beaverton, Oregon 97076 • (503) 526 -2469 Wyatt Fire Protection August 1, 1988 Page 2 If I can be of any further assistance to you, please feel free to contact me at 526 -2502. Sincerely, Ak / Gene Birchill Deputy Fire Marshal GB:kw cc: Tigard Building Department District Inspectors kli.cgC5i 7//9/# CONSOLIDATED FIRE AND RESCUE ® �P �� 7" A el / Washington County Fire District No. 1 1 City of Beaverton Fire Department r 0 Tualatin Fire District • r► FIRE MARSHALS OFFICE July 18, 1988 Mr. Grant Davies 9806 S.W. Tigard Street Tigard, Oregon 97223 RE: AIR /TEQ 9806 S.W. Tigard Street Tigard, Oregon 97223 Dear Mr. Davies: A fire and life safety plan review was conducted on the above captioned project for compliance with the 1985 editions of the Uniform Building Code (UBC). Uniform Mechanical Code (UMC), and Uniform Fire Code (UFC) as amended by Tualatin Rural Fire Protection District's Ordinance 86 -5. Plans are approved for construction subject to the following items: 1. Paint Spray Booth: The Binks Floor Type Paint Spray Booth you intend to install appears to be an acceptable unit. It must be installed in accordance with the provisions set forth in Article 45 of the Uniform Fire Code. Please see attached photocopy for additional details. 2. Dip Tanks: Please provide the material safety data sheets for the products being used in your dip tank operation. If these products are flammable or combustible liquids, the installation of the dip tanks will be subject to the requirements set forth in Article 45 of the Uniform Fire Code. 3. Mechanical Equipment Approval: All heat producing and electrical equipment and appliances installed in conjunction with the construction or occupancy of this project must be approved by Underwriters Laboratories, Inc. or other nationally recognized testing agency and installed in accordance with the testing agency's specifications. (UMC Sec. 502) 4. Address Required: The tenant space number must be prominently displayed on the street front where it is readily visible to drivers and officers of responding fire apparatus and other emergency • vehicles. (UFC Sec. 10.208) 4755 S.W. Griffith Drive • P.O. Box 4755 • Beaverton, Oregon 97076 • (503) 526 -2469 Mr. Grant Davies July 18, 1988 Page 2 5. Approved Plans on Job Site: One set of approved plans bearing the stamps of the Tigard Building Department and this office must be maintained on the project site throughout all phases of construction and must be made available to building and fire inspectors for reference during required construction inspections. (UBC Sec. 303) 6. Inspections Required: Inspection and approval of construction by a representative of this office is required: (a) prior to the cover of any new framing elements following the installation of all utility runs which will be concealed within wall and partition cavities; (b) upon completion of construction and prior to occupancy of the tenant space. (UBC Sec. 305) 7. Required Occupancy Certificate: Prior to the use and occupancy of the project (space), a certificate of occupancy or other written instrument of approval must be obtained from the Washington County Building Department. (UBC Sec. 307) SPECIAL NOTICE: DEVIATIONS FROM THE SUBMITTED AND HEREBY CONDITIONALLY APPROVED PLANS DURING THE COURSE OF CONSTRUCTION, EXCLUSIVE OF THOSE NECESSARY TO COMPLY WITH FIRE SAFETY REQUIREMENTS AS LISTED HEREIN, ARE PROHIBITED WITHOUT THE WRITTEN AUTHORIZATION OF THE WASHINGTON COUNTY BUILDING DEPARTMENT AND THIS OFFICE. If I can be of any further assistance to you, please feel free to contact me at 526 -2469. Sincerely, c ;&4: Jerry Renfro Deputy Fire Marshal JR:kw cc: Tigard Building Department District Inspectors NOTE TO INSPECTORS: A second exit from the second floor office area was ordered by Brad Roast (Tigard Building Department) and was in place at the time of an information inspection on July 15, 1988. Please include this new exit in the final inspection. This exit is the stairway from the upper story leading to the warehouse near the north wall of the building. /Ul z2-y d4 k Ahlraimmam CITY OF TIQA R® June 27, 1988 OREGOP! Mr. Grant Davis Airteq 9806 SW Tigard St Tigard, OR 97223 Dear Mr. Davies: A plan review has been conducted for the installation of a spray paint booth at the above location. The following shall apply: 1. The booth and exhaust duct shall be protected by an approved automatic sprinkler system. 2. Electrical wiring shall comply as for: o Class I, Division 1, inside the booth o Class I, Division 2, outside the booth 3. The electrical equipment shall be interlocked with the ventilation of spraying area so that the equipment cannot be operated without the exhaust fans in operation. 4. The exhaust duct shall have a minimum of 18 -inch clearance to combustible material. If you have any questions, please call 639 -4171. Sincerely, Brad Roast Building Official ht /5580D 13125 SW Hall Blvd., P.O. Box 23397, Tigard, Oregon 97223 (503) 639 -4171 /7 2ZV MEP !CIF - ®® ® ® ® M® �® - MUMMY ■ilr ONMEOW .911217 6119N, NMI 41M117 ® ® ® trlatiSMIN _ A DIVISION OF PACIFIC SECURITY SYSTEMS. INC June 23, 1988 Dear Mr. Roast, Per Fire Marshall Bob Ray's recommendations, during his visit this week, we are moving the exit. We are moving steps from the back of the office to the side to give immediate access to the front door. Also we are beefing up the hand rail for more stability. Internally, also to Fire Marshall Bob Ray's recommendation, we are replacing the hand rail on the stairs with another style which will curve down at each end to avoid snagging sleeves. We hope this is helpful. Sincerely, Grant Davies GD /rb • 1 1735 N.E. Sumner St. • Portland, OR 97220 • (503) 257 - 7770 FAX (503) 255 -7851 RECEIVED JUN 9 3 1988 • #07.- „N , i Washington County Fire District No. 1* ` J City of Beaverton Fire Department Tualatin Rural Fire Protection District June 16, 1988 A.S.I. Heating & Air Conditioning 17555 S.W. 65th Avenue Lake Oswego, Oregon 97035 RE: Air Teq 9806 S.W. Tigard Street Tigard, Oregon Gentlemen: A fire and life safety plan review was conducted on the above captioned project for compliance with the 1985 editions of the Uniform Building Code (UBC), Uniform Mechanical Code (UMC), and Uniform Fire Code (UFC) as amended by Tualatin Rural Fire Protection District's Ordinance 86 -5. Plans are approved conditional to the following items: 1. Approved Plans on Job Site: One set of approved plans bearing the stamps of the Tigard Building Department and this office must be maintained on the project site throughout all phases of construction and must be made available to building and fire inspectors for reference during required construction inspections. (UBC Sec. 303) 2. Inspections Required: Inspection and approval of construction by a representative of this office is required: (a) prior to the cover of any new framing elements following the installation of all utility runs which will be concealed within wall and partition cavities; (b) upon completion of construction and prior to occupancy of the tenant space. (UBC Sec. 305) 3. Certificate of Occupancy Required: Prior to the use and occupancy of the project (space), a certificate of occupancy or other written instrument of approval must be obtained from the City of Tigard Building Department. (UBC Sec. 307) SPECIAL NOTICE: DEVIATIONS FROM THE SUBMITTED AND HEREBY CONDITIONALLY APPROVED PLANS DURING THE COURSE OF CONSTRUCTION, EXCLUSIVE OF THOSE NECESSARY TO COMPLY WITH FIRE SAFETY REQUIREMENTS AS LISTED HEREIN, ARE PROHIBITED WITHOUT THE WRITTEN AUTHORIZATION OF THE WASHINGTON COUNTY BUILDING DEPARTMENT AND THIS OFFICE. !} A A.S.I. Heating & Air Conditioning June 16, 1988 Page 2 If I can be of any further assistance to you, please feel free to contact me at 649 -8577. Sincerely, TUALATIN FIRE DISTRICT 0411111,/4-- aLSIA Gene Birchill Building Official 20665 S.W. Blanton Street Aloha, Oregon 97007 GB:kw cc: Tigard Building Dept. District Inspectors 4 � , 0 ` ��� Washington County Fire District No. 1 City of Beaverton Fire Department e, fgt Tualatin Rural Fire Protection District . 1,x,1 June 3, 1988 R.A. Gray & Company P.O. Box 23516 Tigard, Oregon 97223 RE: Tenant Modification - Air -Teq 9806 S.W. Tigard Street Tigard, Oregon Gentlemen: A fire and life safety plan review was conducted on the above - captioned project for compliance with the 1985 editions of the Uniform Building Code (UBC), Uniform Mechanical Code (UMC), and Uniform Fire Code (UFC) as amended by Tualatin Rural Fire Protec- tion District's Ordinance 86 -5. Plans are approved as submitted subject to the following items: 1. Firestopping: In all wood - framed walls and partitions, fire - stopping consisting of 2 -inch nominally -sized lumber or other approved materials must be installed at all floor and ceiling levels. Penetrations in this prescribed firestopping to accommodate wiring, plumbing, and other similar utility runs must be packed with noncombustible materials in an . approved manner so as to prevent the passage of flame. (UBC Sec. 2516) 2. Approved Plans on Job Site: One set of approved plans bear- ing the stamps of the Tigard Building Department and this office must be maintained on the project site throughout all phases of construction and must be made available to build- ing and fire inspectors for reference during required con- struction inspections. (UBC Sec. 303) 3. Certificate of Occupancy Required: Prior to the use and occupancy of the project (space), a certificate of occu- pancy or other written instrument of approval must be obtained from the City of Tigard Building Department. (UBC Sec. 307) R.A. Gray & Company June 2, 1988 - Page 2 SPECIAL NOTICE: DEVIATIONS FROM THE SUBMITTED AND HEREBY CONDITIONALLY- APPROVED PLANS DURING THE COURSE OF CONSTRUCTION, EXCLUSIVE OF THOSE NECESSARY TO COMPLY WITH FIRE SAFETY REQUIREMENTS AS LISTED HEREIN, ARE PROHIBITED WITHOUT THE WRITTEN AUTHORIZATION OF THE WASHINGTON COUNTY BUILDING DEPARTMENT AND THIS OFFICE. If I can be of any further assistance to you, please feel free to contact me at 649 -8577. Sincerely, TUALATIN F STRICT t t *l Bert •:rke Fire •rsh.l 20665 S.W. :lanton Street Aloha, Oregon 97007 BP:kw cc: Tigard Building Dept. District Inspectors