Correspondence _. July 9, 1998 CITY OF TIGAR OREGON Carlson Testing P.O. Box 23814 Tigard, OR 97281 V PERMIT NO: - 610 98 -0225 OWNER: Progressive Ins. PROJECT ADDRESS: 7150 SW Sandburg PROJECT DESCRIPTION: Office TYPES OF SPECIAL INSPECTION: Structural special inspections The owner has notified us that he/she will retain your services to perform Special Inspections in accordance with the provisions of the State Building Code, permit documents, and special inspection requirements. The owner or the owner's agent must also confirm with you that they have authorized you to do the special inspection work. As the regulatory agency, the City requires that you do the following: 1. Submit copies of all inspection reports promptly to the Building Division, architect, engineer, and the contractor. 2. Maintain one copy of each field report at the job site. 3. Submit a final report at the completion of each category of work that you inspect. (See U.B.C. 3318 for soils special inspection final report requirements). If you fail to comply with the above requirements, there may be cause for the City to revoke your authority as special inspector for this job. Should you have any questions, please call the Building Division at (503) 639 -4171. . Sincerely, • fro ert Poskin, CBO • Senior Plans Examiner Enclosure I:1ofsltemplate1 notify dot 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 H ,' June 23, 1998 CITY OF TIG� OREG Ankrom Moisan Architects 6720 SW Macadam #100 Portland, OR 97219 RE: Progressive Insurance Building Plan Review 7150 SW Sandburg PC #: 6 -29c BUP#: 98 -0225 Use: "B" Construction 5N (with 2 hour area separation wall) Area: 23562 Occupant Load: 540 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1996 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: E 1. Submit Completed Energy Compliance Forms 5a through 5c, Oregon Non - Residential Energy Code. ACC SS'IBILI: z2y, 1. Pursuant to OSSC, Section 1113 (4)(a) - The accessible parking shall be on an accessible route to the building, OSSC, ADAAG9. You may elect as an alternate to ADAAG9, as per the enclosed detail. 2. Provide details for ADA accessible showers and lockers. 1. In order to have your area separation wall to comply, the basement floor must run in line with the upper floor. See the attached drawing, OSSC, Section 504.6.4. 2. Doors - OSSC, Section 1005.8.1 A. 23A shall be labeled 1 -1/2 hour, B. 23B shall be labeled 20 minutes, 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Progressive Insurance Building Plan Review PC #: 6 -29c BUP #: 98 -0225 Page #2 C. 506 B shall be labeled 1 -1/2 hour, D. 114/116 shall be labeled 20 minutes, E. 28A/28B shall be labeled 1 hour (OSSC, Section 302.3) 3. Provide exit illumination and signs to include backup power at the following areas (OSSC, Section 1012/1013). A. Training room at doors 28A/28B, B. At doors 12A/13ABC/23A -B/24, C. At door 18 with arrow indication, D. At doors 109/ 109A- B/505E/505B/103/105/204A/204C. 4. Area separation wall termination - A. Your plans show perpendicular termination, however, it appears you will have parallel termination, provide details (OSSC, Section 504.64). 1. Complete the enclosed Structural Special Inspection form designating an Approved Testing Laboratory [Line B] and signed by the owner of the project - [Line D]. A. The completed form must be returned to this office before a building permit can be issued. B. Copies of all special inspection reports shall be filed with this office continually during construction. C. Final signed report must be on file before an occupancy certificate will be . issued [OSSC, Section 1701.3]. i a l A separate application, plans and permit will be required. Due to the placement of the area separation wall, the mechanical plans must be detailed and imposed over the floor plan. E N ME_ NTA,L R - Provide details on how you will comply with OSSC, Chapter 12. Separate permits will be required for plumbing and electrical. Progressive Insurance Building Plan Review PC #: 6 -29c BUP#: 98 -0225 Page #3 Please submit two copies of revised submittal documents and a letter indicating your response to the above comments for review. Please call me at (503) 639 -4171 if you have any questions. Sincerely, doiury eisp • R ert Poskin, CBO SENIOR PLANS EXAMINER Enclosures • • • 7►-3�d3`L P7r w I s OA trd IV ti (RMett p -\"? ` I• t I• CITY OF TIGARD A Program for Inspection Services and/or Material Testing Date: 44111 ,191€ City of Tigard: Plan Ck. No. Bup No. gQ -o2Z5 Sit No. Project Title: Ptz Qern,JE 2 . Address g1So sua 5a.aD6ueb. RD Architect of Record 4,.1e24m blots.+ Aa Cw- ,rnc,e Ph. 24s -1-too address: (o' 20 S&) Ateaalare ` ilert.A.4D Structural Engineer of Record: usu2M_ G Jee 4 Ph. 2W - A-o address: I150 Su.) t * Gjwb Geo- Technical Engineer of Record: Ph. address: Provide the following information for the testing agency chosen to provide inspection services and/or testing. Testing Agency: Ph. Fax. address Geo- Technical Agency: Ph. Fax. address The owner certifies that the above noted Agency has been employed to conduct the special inspections or observations required herein. Sienature of owes Phone No. Date Print name Company name The following is a list of special inspection and/or services required by the 1996 Oregon Structural Specialty Code and Tigard's Municipal Code 14.06.010 through 14.06.040. The special inspections and/or testing services required for this project to be provided by the Testing Agency, Structural Engineer or Geo- Technical Engineer of Record are as follows: • Special Inspectors for the Testing Agency shall be qualified, to the satisfaction of the Building Official, for inspections of the particular type of construction or operation. • Special inspectors shall observe the work assigned herein for conformance with the approved plans and specifications and, submit copies of all inspection reports and. a final signed report in accordance with OSSC, Section 1701.3 to the building official. MEM ■o■ EMI ■.■ ■ ■. ANKROM MOISAN ASSOCIATED ARCHITECTS July 8, 1998 Mr. Bob Poskin, CBO Senior Plans Examiner City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Re: Progressive Insurance - Building Plan Review 7150 SW Sandburg Road BUP#: 98 -0225 Dear Mr. Poskin: ENERGY COMPLIANCE 1. Please see attached completed energy compliance form 5C. ACCESSIBILITY 1. Accessible parking route, please see attached drawing SD -9, dated July 7, 1998. 2. ADA showers, please see attached drawing SD -7, dated July 7, 1998. ADA compliant lockers noted on plans, Sheet A2.1. FIRE AND LIFE SAFETY 1. Area separation, please see attached drawing SD -3, dated July 7, 1998. 2. Wall alignment, door schedules have been updated on plans, Sheet A2.3. 3. Exit illumination and signs noted on plans, Sheets A3.1, and A3.2. 4. Area separation wall termination, please see attached drawing SD -8, dated July 7, 1998 Sincerely, ANKROM MOIS • ASSOCIATED ARCHITECTS I Michael B n Enclosures MB /el 6 s.w. Macadam. Suite 10o, Portland, Oregon 97 5 FAx 503/245 -7710 Pnncipals: Stewart H. Ankrom, Thomas Moisan, David N. Vonada, Lorraine C. Kellow, Jeff Hamilton, Karen Bowery I ` Oct -12 -98 08:30A Structural Concepts S03- 292 -4104 P.02 Structural Conce iS .•.• •.. • E • October 12, 1998 Mr. David Vonada Anlcrom Moran Associated A.ddtecb .' 6720 SW Macadam Avenue, Suite 100 Portland, OR 97219 • • • • Re: Progressive Insurance Remodel / � 5 a g 4 • Dear Dave: • • As requested, Structural Concepts LLC has completed a review of the roof structure of the • Progressive Insurance Building in Tigard, Oregon, for the ability to support ponded water in the event that the roof drains are clogged. Potential ponded water depths were based on information • provided by McCormack Pacific in their roof slope survey which is attached. • The northeast quadrant of the roof structure ponds the most water, and this critical area was found • to be structurally adequate to support the additional load produced. All other areas of the roof structure are less critical and are adequate as constructed. • Please call if you have any questions or require additional information. • Sincerely, • • / A OP / • Principal • * °1N 44 4. 15.370 • onzaton 6K • •p Y.. O 1x•99 • 44 4 . 12 PAW • • 1750 SW Skyline Blvd, Suite 223 • Portland. Oregon 97221 503.292.4540 • fax 503.292.4104 • email atruetcon@aol.com • • • • • 6 McCORMACK PACIFIC GENERAL CONTRACTORS • CONSTRUCTION MANAGERS . 7190 SOUTHWEST SANDBURG STREET • TIGARD,•OREGON 97223 • \• •J.b aQ es i c in 5t. an c c Job No. ' 9 Date /gig I 0 Phone ❑ Conference 0 Memo With ::' • Subject 5to rr , tDR6j - i :: _z5'— -- i �Y r g,, / AM • 5" s�R RQae . J ` • • / 5v wait . • g" sub • • 2 5 , / • \ auite2 spill • 0 , \ ,, il ,,, i•, •,■ ••,j• ip • 11•ri e "..., � . ' `�� 1 :::.:.:• \ it ,:e \ a • .%,.....,.. l.' : Q (it. \,..^.- ..Distribution: • �•: ,. _ _. 0 , _ _ -_ By , / -'f ,� 1 4/2 0 k _