Permit CITY OF TIGARD DEVEL0PMENT SERVICES F'ERMBUILDING PERMIT TF'98 —Qi225 Tigard, OR (503)639-4171 DATE ISSUED: 08/03/98 PARCEL: 25101DC -03900 SITE ADDRESS...: 07150 SW SANDBURG ST SUBDIVISION • SALEM FREEWAY SUBDIVISION ZONING:C —P BLOCK LOT •004 JURISDICTION:TIG REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION — CLASS OF WORK.:ALT FIRST : 23562 sf N: S: E: W: TYPE OF USE•..:COM SECOND...: 0 sf PROTECT OPENINGS? TYPE OF CONST.:SN ••.: 0 sf N: S: E: W: OCCUPANCY GRP. :B TOTAL : 23562 sf ROOF CONST: FIRE RET ?: OCCUPANCY LOAD: 540 BASEMENT.: 8427 sf AREA SEP. RATED:2HR STOR.: 1 HT: 0 ft GARAGE...: 0 sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD •100 psf LEFT: 0 ft RGHT: 0 ft FIR SPKL:Y SMOK DET..: DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM: HNDICP ACC:Y BEDRMS: 0 BATHS: 0 IMP SURFACE: 0 PRO CORR:Y PARKING: 0 VALUE. $ : 300000 Remarks : Interior tenant improvement Owner: FEES PROGRESSIVE INSURANCE type amount by date recpt 6300 WILSON MILLS RD PLCK $ 606.45 B 06/08/98 98- 306361 MAYFIELD VILLAGE OH 4 FIRE $ 373.20 B 06/08/98 98- 306361 PRMT $ 933. JSD 08/03/98 98- 307899 Phone #: 440 - 446 -3044 SPCT $ 46.65 JSD 08/03/98 98- 307899 Contractor: MCCORMACK PACIFIC CO 7190 SW SANDBURG ST TIGARD OR 97223 Phone #: 624 -2090 $ 1959.30 TOTAL Reg #..: 000631 -- REQUIRED ACTIONS or INSPECTIONS--- - This permit is issued subject to the regulations contained in the Foot /Found Insp Tigard Municipal Code, State of Ore. Specialty Codes and all other St r u c Steel Insp applicable laws. All work will be done in accordance with R e i n f Steel Insp approved plans. This permit will expire if work is not started Framing Insp within 180 days of issuance, or if work is suspended for more Insulation Insp than 180 days. ATTENTION: Oregon law requires you to follow the Shear W a l l Insp rules adopted by the Oregon Utility Notification Center. Those F i rewa l l Insp rules are set forth in OAR 952191 -0010 through OAR 952-00101987. Gyp Board Insp You many obtain a copy of these rules or direct questions to OUNC Susp Ce i l n g Insp by calling (503)246 -1987. SMRF concrete fi SMRF welds final / Structural weldi Permittee Signature / iggrm, U. Issued By: �_�_ Y• + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ et + + + + + + + + + + + + + + + + + + + + + + ++ + + + + + + + + + + + + + + + ++ Call 639 -4175 by 7:00 p.m. for an inspection needed the next business day +++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ tf m J el a 9C°_ L CITY OF TIGARD Commercial Building Permit Rec'd By 13125 SW HAIL' BLVD. Tenant Improvement Date Recd 6-- q" TIGARD, OR 97223 Date to P.E. i — l / / Date to D, _Z Id .2z (503) 639 -4171 Permit # ) — if 7 Print or Type Related SWR # Incomplete or illegible applications will not be accepted Called . /._:L(mac. / / / , / , _ ' S - . / 1 / 4 / / . 7i7/96P Name of Development/Project Existing Building$.. New Building ❑ Job Fiteo21,5aUe t Address Street Address I Suite Building 1 MO 1 . SAIN ga Data Bldg # City /State Zip Existing Use of Building or Property: 4/4; ' RED, o .y'I �z3 8 — Office Name Property FR tVI� Proposed Use of Building or Property: Owner Mailing Address -- __ Suite l _ G (R�l FA • No. Of Stories: City/State ( T t1t1wj o. Phone I * 1 ta'taeW� Sq. Ft. Of Project: Occupant Name 2.x 2 - matt& F✓ � Oulkot (440)444-SO44- Occupancy Class(es) Name Contractor V,L c j tG Type(s) Prior to permit Mailing Address Suite V -1.1 issuance, a copy 11909 Will this project have a Fire Suppression System? of all licenses l ��+ +•�+•• Yes ❑ No fgt. are required if City/State Zip Phone Americans with Disabilities Act ADA expired in C.O.T. f L� W4421/2093 ( ) l database Valuation X 25% = Participation OregoConst. Cont. Board Lic.# Exp. Date Complete Accessibility Form 1 Aggigt ei✓It I Project $ Name Valuation k 3001 000 Architect M rn(xol,(t�k,(� Plans Required: See Matrix for number of sets to submit �Ma a il li in � g � Address Suite on back (5 ?'2L S.W. YYlaea t * (00 City /State Zip Phone I hereby acknowledge that I have read this application, that the information Chi 91n t9 1 •(„ �� given is correct, that I am the owner or authonzed agent of the owner, and L.L � that plans submitted are in compliance with Oregon State Laws. Engineer Name I _ C . Si nature of Owner /Agent Date Mailing Address r Suite I A , _ ‘7e ) f1& Sklibtao 1314.42225 Contact Pe i , 'a e Phone City /State Zi Phone k/ 00144 FOR OFFICE USE ONLY Indicate type of work: New 0 Addition 0 Demolition 0 Map/TL# /7 ' r y Land Use: Accessory Structure 0 Foundation Only 0 Alterationpt: _ C.�'" �� Repair 0 Other 0 Notes: Description of work: TIF: Parks: Estimated # of Emp r Th Note: Site Work Permit Application must precede or accompany Building Permit Application l:\COMNEW.DOC (DST) 8/97 k 1 I, r -, t 4, COMMERCIAL PLAN SUBMITTAL REQUIREMENT MATRIX SubtradePlan :Review.is:dependent: i :i l of B OTH : ,plans AND a:COMPLETE }..;:. :. -.. For an electrical submittal, the application: must contain :the':: ;.::;::.,: - the: supervising :: electrician'before: plan.:., review will be conductec€.::;.::•: :"•:.: DISTRIBUTION TO PLANS! . *• . • . • . OJJT•• TQ DST EXAMINERS (Note a.) _ TYPE OF SUBMITTAL TOTAL CPE PPE • EPE • • - ':CI'E • ' PPE EPE SITE • .. . - 1 1 •,'. ... ; -• ' `3 (,o,u) -- -- B (New or Add) 1 1 : ", • -- ; 3 (j. :o,w) t ' -.- .. -- F (New or A dd or A lt.) 3 3 -- -r 3, (;o,f) ' , 1(4' • New o; Add. or•Alt } ' - 1 1 -- •-,- ,. 2 (j,o) . • • ' - -. -- 1 &"M :(NeW or Add) - • 1 1 -- •' • -- * 3 (j,o,w) . -- -- P (New, Add. or Alt) - • 2 -- 2 . -- . . -- • • , • 2(j,o) -- B & M & P (New or Add ) 2 1 1 -- 3 (j,o,w) 2(j,o) -- E (New, Add, or Alt) 2 -- -- 2 -- -- 2(j,o) B & M & P & E (New, Add) 3 1 , • V • 1` • 3 (j,o,w) ' ' 2(j,o) 2 (j,o) B -:I S > &: Alt : -< :3 :1: >' ' . : ?2::*. :- ' ;: 2 ' & & E.. Alt ' .- . ... . - : - _;' :: . <•:?'t; :;'', '::.::' ::':` ... fi ..:; .:..,. ::• ; `:. NOTES: • ' '• ' KE1?: ' • ' a. Before returning to DST, Plans examiner gets appropriate j = Job , , B = BUP number of revised plans from applicant, stamps and • • ' o= • Office - • ' • M = MEC completes, updates and adds actions. . , •, f = Fire .. P = PLM • u =OSA ' -' E =ELC : b<.. Shar#e0:areas .eesigriaife R T.subniittOs' only: ;,:,,::.::: w = Wash. CounA .. F = FPS .. c. FPS is a new permit category set aside for fire sprinklers and fire alarms. d. Effective August 15, 1997, Tualatin Valley Fire and Rescue no longer requires a set of approved plans to be forwarded to their office. Exc' ption, continue to forward a copy of approved ,fine sp and fire alarm plans with. • , • calculations. . I.lmatnx.Doc • OVER THE COUNTER OTC ER ER ( _ ) (attachment to Submittal Criteria) SUBJECT: ACCESSIBILITY BARRIER REMOVAL IMPROVEMENT PLAN REQUIREMENT: OREGON REVISED STATUTE (ORS) 447.241. (1) Every project for renovation, alteration or modification to affected buildings and related facilities shall be made to insure that the path of travel to the altered area and the restroom, telephones and drinking fountains are readily accessible to individuals with disabilities, unless such alterations are disproportionate to the overall alterations in terms of cost and scope (2) Alterations made to the path of travel to an altered area may be deemed disproportionate to the overall alteration when the cost exceeds twenty-five per -cent (25 %). THEREFORE; Each submittal for a building permit shall include this form providing the following information. [Excluding re- roofing, mechanical and electrical permit applications] VALUATION of all renovation, alteration or modification being done excluding painting, wallpapering. [1] $ '70 , 00 multiply; 25% Barrier removal requirement _ .25_ BUDGET FOR BARRIER REMOVAL [2] $ 7' f ddb The dollar amount of the BUDGET established on line (2) in the computation above shall be spent providing the accessible elements in the following order. 1. An accessible route connecting the building to accessible pedestrian &� )) walkways, and the public way. $ I� 4 (including but not limited to curb ramps, detectable warnings, marked crossings, ramps handrails and landings). 2. Not less than one accessible parking space. $ 5 NO (including but not limited to adjacent access aisle, signs and curb ramp connecting with the accessible route). 3. Accessible entry or entries. $ . I • ( (including but not limited to ramps, handrails, landings, door sill height, door width and door hardware). 4. An accessible interior route to the altered area. $ K f A (including but not limited to door -ways, maneuvering clearances, door hardware and stairways). 5. At least one accessible restroom for each sex. $ £� 6. At least one accessible telephone where public phones 1 are provided. $ 1`+ A 1X ) 7. When drinking fountains are required, fifty per -cent but not less than one shall be accessible. $ i `► �.t� 8. Additional accessible elements such as storage, reach ranges, alarms, etc.. $ 1- TOTAL; Shall equal line 2 of Value Computation $ 7 C 1 Ott is /otca.doc(DST) • UNIFIED SEWERAGE AGENCY OF WASHINGTON COUNTY FIXTURE UNIT RATINGS TOTAL TOTAL FIXTURE VALUE NUMBER NUMBER BAPT I STRY/ FONT 4 BATH - TUB/ SHOWER 4 - JACUZ /gHPL 4 CUSPIDOR /WATER ASP 1 DISHWASHER - C06114ER 4 DOMEST 2 DRINKING FOUNTAIN 1 // FLOOR DRAIN - 2 I NCH 2 •r - 3 I NCH 5 II / �- - 4 INCH 6 GARBAGE DISPOSAL - DOM (TO 3/4 HP) 16 - COMM (TO 5 HP) 32 - IND (OVER 5 HP) 48 OIL SEP (GAS STA) 6 SHOWER - GANG 1 - STALL 2 {{�cc /J � !� SIf ( - BAR 2 /1/7 ` //I / G�� - BRADLEY 5 - COFIMERC I AL 3 - SERVICE 3 /// %/ WASHER, CLOTHES 6 WATER EXT 6 WATER CLOSET 6 A J 1 � 72 UR I NAL 6 /// v - ,„ - a 664 g7n A/0. 61 631 DATE 4/5/9 I NSP TOTAL BUS I NESS ( aL/1 kc c./ -cft e ( ,/ - EDU ADDRESS 7 Z5 y ) �/7lJlXA/'1'7 PERM i T ND . / TAX MAP /LOT COUNTED FROM l� -,s ion /.90x7 9a/ 73 -25 R83 1/21/00 Activities for Case #: BUP98 -00225 2:18:34 PM Assigned Hold Updated _ Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes BUPC005 Application received • 6/8/98 GEO RECD. TLP 8/6/98 • BUPC008 Permit created 6/9/98 B DONE BON 6/9/98 BUPC012 Plans routed to Plans Examiner 6/9/98 B SENT BON 6/9/98 BUPCO26 APProved Plans routed to DSTs 7/9/98 RDP APPR RDP 7/9/98 - BUPC520 Mechanical Permit Required 7/9/98 RDP 7/9/98 BUPC530 Electrical Permit Required 7/9/98 RDP 7/9/98 BUPC540 Sprinkler Permit Required 7/9/98 RDP 7/9/98 BUPC565 Plumbing Permit Required 7/9/98 RDP 7/9/98 BUPC705 Foot/Found Insp 7/9/98 8/6/98 TLP PASS TLP 8/6/98 Notice - This is a steel momemt frame - All work regarding this frame is by Speaal Inspection interior footings grid d to f line 2 BUPC715 Struc Steel Insp 7/9/98 RDP 7/9/98 BUPC716 Reinf Steel lnsp 7/9/98 RDP 7/9/98 • BUPC740 Framing Insp 7/9/98 8/27/98 RDP NOTE RDP 8/27/98 There is an amendment to the permit for the structural changes required in the roof • framing to support the new • mechanical system. See addendum attached to sheet S -1- ?s see Bob Poskin BUPC750 Insulation Insp 7/9/98 RDP 7/9/98 BUPC757 Shear Wall Insp 7/9/98 8/25/98 TLP PART J *H 8/30/98 WALL GRID LINE E SHEAR NAILING FROM 3 -5. BUPC758 Firewall Insp 7/9/98 10/12/98 RC PART J *H 10/15/98 1ST LAYER ON RATED CEILING & FRAMING BUPC760 Gyp Board Insp 7/9/98 8/24/98 TLP PART TLP 8/24/98 ceiling only 50% BUPC762 Susp Ceilng lnsp 7/9/98 10/22/98 RC PART ROC 10/23/98 BASEMENT SYSMIC APP. . NEED FIRECAULK AND DAMPER INSP BEFORE COVER BUPC766 SMRF concrete final report 7/9/98 11/20/98 RECD J *H 11/23/98 fax routed to file Carlson Testing Final Summary Letter • of 111998: Reinforced Concrete . Epoxy Anchors Structural Steel - Shop & Field BUPC767 SMRF welds final report 7/9/98 RDP 7/9/98 BUPC768 Structural welding final reprt 7/9/98 RDP 7/9/98 BUPCO29 DST Post Review Completed 7/9/98 DLH DONE DLH 7/9/98 BUPC090 (F) Ready to issue 7/9/98 DLH PASS DLH 7/9/98 • • Page 1 of 3 • 1121/00 Activities for Case #: BUP98 -00225 2:18:34 PM Assigned Hold Updated . Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes BUPC100 (F) Issue permit 8/3/98 JSD PASS DST 8/3798 BUPC760 Gyp Board Insp 8/25/98 TLP PASS TLP 8/25/98 2nd layer,ceiling room 501 BUPC740 Framing Insp 8/27/98 9/1/98 TLP PART TLP 9/1/98 SERVER ROOM /AND MPF ROOM NO ELECTRICAL TO BE COVERED BUPC760 Gyp Board Insp 9/1/98 TL' PASS TLP 9/1/98 SECOND LAYER CEILING BUPC760 Gyp Board Insp 9/11/98 TLP PART J*H • 9/11/98 rated ceiling at 2nd floor - 1st layer of 2 -hr ceiling approved. BUPC740 Framing lnsp 9/11/98 TLP PART J *H 9/11/98 1st floor framing BUPC740 Framing Insp 9/18/98 GS PASS J*H 9/21/98 1. Framing complete except mech chases at corridor 109 and grid E6 - PASS. NOTE: Note to electrical contractro: non - dedicated outlet boxes need to be kept 15- inches min. above FF insulation paper to bottom of box. BUPA740 Gyp Board Insp 9/18/98 GS PASS J*H 9/21/98 1. Gyp board grids B -C 1 -7 and training room #28. BUPA730 Insulation Insp 9/18/98 GS PASS TLP 10/2/98 1. Plenum insulation paper approved. 2. FS paper complete, wood framing • • members need to be wrapped. BUPC760 .Gyp Board Insp 9/23/98 RC PART J'H 9/23/98 Basement section 2 - 9 feet on walls. BUPC760 Gyp Board Insp 10/1/98 TLP PASS TLP 10/2/98 BUPC758 Firewall Insp 10/2/98 TLP PASS TLP 10/2/98 second layer area seperation wall BUPC760 Gyp Board Insp ' 9/30/98 RC PART J*H 10/5/98 Area in orange BUPC760 Gyp Board Insp 9/28/98 RC PART J'H 10/7/98 areas in orange BUPC760 Gyp Board Insp 10/9/98 RC PART ROC 10/9/98 LIDS IN ALL 4 BATHROOMS • 2ND LAYER IN JANITOR • ROOM BUPC758 Firewall Insp 10/13/98 TLP PART J*H 10/13/98 BOTTOM LAYER CORRIDOR #109 • Page 2 of 3 . 1/21/00 Activities for Case #: BUP98 -00225 2:18:34 PM • Assigned - Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes BUPC802 Final Inspection 11/19/98 RC FAIL J'H 11/23/98 thisT.l. has plumbing /fps /elec/mech Inspection of 111998: 1. Needs final reports (welds /concrete). 2. • Place handicap signs at parking spots. 3. Place handicap directional sign to accessible entry and parking. 4. Need handicap rail at entry. 5. Needs hardservice 24- inches from toilet/urinal. 6. Doors to rated corridor must be self - closing, self - latching. 7. Need smoke gaskets several places. 8. Need fire extinguisher mounted. 9. • Need test on fire curtains. 10. Need to test magnetic release • on fire doors. 11. Need unloading zone for handicap BUPC758 Firewall Insp 10/26/98 10/23/98 RC PART . J'H 10/26/98 Downstairs corridors - check over duct at final in bathroom. BUPC762 Susp Ceilng Insp 10/26/98 10/23/98 RC PART J *H 10/26/98 Downstairs corridors, check over duct at final in bathroom. BUPC740 Framing Insp 11/2/98 10/29/98 RC NOTE J *H 11/2/98 FIRECAULKING NOT READY BUPC757 Shear Wall Insp 11/2/98 J'H 11/2/98 BUPC758 Firewall Insp 11/2/98 10/29/98 RC FAIL J'H 11/2/98 FIRECAULKING NOT READY BUPC762 Susp Ceilng Insp 11/2/98 10/29/98 RC PART J *H 11/2/98 OPEN OFFIC, 505 COMPLETE & NW OFFICE 301 -307. BUPC762 Susp Ceilng Insp 11/2/98 11/4/98 RC PASS J'H 11/4/98 all suspended ceilings entire bldg. BUPC762 Susp Ceilng Insp 11/4/98 J'H 11/4/98 BUPC758 Firewall Insp 11/4/98 11/4/98 RC PASS J *H 11/4/98 firewalls approved complete both floors. BUPC802 Final Inspection 11/24/98 RC PASS J *H 11/24/98 BUPC070 HOLD FOR (Note in Action Memo) 12/4/98 JT 12/4/98 hold c/o; e1r98 -0257 has not had a final inspection, e-mail to ron/hap/jean/chuck BUPC950 (F) Issue Cert. of Occupancy 11/24/98 MAIL VLN 12/29/98 mailed 12/29/98 Plans to • Records for microfilming 12/29/98. • • Page 3 of 3 • • CITY OF TIGARD BUILDING INSPECTION DIVISION MST 14 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 Q L 0 p [ ta , C, 170z-- , Date Requested AM PM BLD ` ^ 1 � Location 7150 c3 - ( � ( n ) ) � Q/h Suite r MEC Contact Person ( W/ v Ph NOT 6 1let PLM • ' Contractor I _ ,ii IL' ' 1. � Ph SWR II BUILDINj) Tenant/Owner P ' G,SS( V I- // J3' ELC inmg Wall ELR Footing ACC S: Foundation .l p , FPS Ftg Drain • —. ii.. ..�i ..c�_., = =' �W l Crawl Drain Inspection Notes: SGN Slab SIT ��__,,��,,�� /g�j Post & Beam i�t(.�'/VLU�� � 1 (//C• Ext Sheath /Shear Ina Sheath /Shear rr �� Framing fir pii n , ,0 , ee Insulation D _ / 4_ Drywall Nailing 9 P�.cs.f ��.." /.) .f c f^-e Firewall 1 � Fire Sprinkler • Fire Alarm / i(] ,,, _ ) 1 . I _.- / Susp'd Ceiling C9 �J�L_ y -.1..-..- -.1..-..- ....-._• ....-._• I : � '- - ..f if � _ Roof r M StS Fi /� , - D `0 / , 1 i PART FAIL ` `� {J �� / PLUMBING ( . 0 C : t4- . / .., • C . ti Post & Slab o- v v (Mt Under Slab ► lt � Top Out ( a_0 -t/ % ti f " .0/ e-- / . -1.-e— Water Service Sanitary Sewer _ Rain Drains C_ Visari_2.1-‘47 / , � , - Final PASS PART FAIL _ MECHANICAL 0 _ / I Post & Beam Rough In Ot)6P0 - 0 G:- Gas Line Smoke Dampers 40 "V' n_+�1� � "" � r /l //h Final ' �-' ■ PASS PART FAIL I . ELECTRICAL 6 �' % � A I . Service ` .4 _ • _.4� ■ ._..' Ou A Rough In �� 4 , �/,� !I Q / - its i I o6 a p l pte ' UG /Slab o Vim- Low Voltage (J co ,c g - q p- --O , � /� d ce �� /' Fire Alarm �C� q O p CA N Final l U - 5 7 /&t Q/ot&} PASS PART FAIL SITE Wr Backfill/Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA P P G Inspector J 1 Approach /Sidewalk `� I It Other Date Ext h Final PASS PART FAIL. DO NOT REMOVE this inspection record from the job site. Pr OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP MST 2 �� i� >r Date Requested J) • r � A PM BLD Location -7 l t , Suite MEC Contact Person ,�,� ( Ph 7 q q - ‘("0 (Q PLM • - - ..r Ph SWR BUILDIN . Tenant/Owner e ELC • ' • ! Tall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof 4r PAS PART FAIL P _ I MBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains • Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk D \i\ - J InS C'• Ext Other Inspector p Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.