Permit 3 CITY OF TIGARD MASTER PERMIT
4, DEVELOPMENT SERVICES PERMIT # • MST99 -0053
.4191 6 . i 13125 SW HaII Blvd., Tigard, OR 97223 (503)639-4171 DATE ISSUED: 0 / x.9 / 99
PARCEL: 29110BA —RED13
SITE ADDRESS...:11879 SW TREEHILL CT
SUBDIVISION :REDWOOD VISTA ZONING: R -4.5
BLOCK LOT •013 JURISDICTION: TIG
Remarks: PATH I: New single family dwelling w /attached garage & deck.
BUILDING
REISSUE: STORIES • 2 FLOOR AREAS BASEMENT...: 0 sf REQUIRED SETBACKS— REQJIEED
CLASS OF WORK.:NEW HEIGHT • 20 FIRST • 1355 sf GARAGE • 660 sf LEFT • 5 SMOKE DETECTRS: Y
TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 998 sf FRONT • 29 PARKING SPACES: 2
TYPE OF CONST.:5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT : 5
OCCUPANCY GRP.:R3 BDRM: 3 BATH: 3 TOTAL - -: 2353 sf VALUE..$: 178074 REAR • 25
PLUMBING
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 1 RAIN DRAIN ft: 1w. TRAPS • 0
LAVATORIES....: 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 1'.' SF RAIN DRAINS: 1 CATCH BASINS..: 0
TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1% BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
MECHANICAL — —
FUEL TYPES FURN (100K ..: 0 BOIL /CMA ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1
GAS FURN ) =100( ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WODDSTOVES • 0 SAS OUTLETS...: 1
- -- — ELECTRICAL --
- RESIDENTIAL UNIT— — SERVICE /FEEDER— —TEMP SRVC /FEEDERS— — BRANCH CIRCUITS— — MISCELLANEOUS— — ADD'L INSPECTIONS -
1m SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FOR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 5 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0
LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT : 0
MANF HM /SVC /FDR: 0 601 - 1'.w. amp.: 0 601+amps- P v: 0 MINOR LABEL -10: 0
1000+ amp /volt.: 0 -- -- PLAN REVIEW SECTION --
Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC:
- — ELECTRICAL - RESTRICTED ENERGY — -----
A. SF RESIDENTIAL B. COHIAERCIAL
AUDIO & STEREO.: X VACUUM SYSTEM..: X AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: X DTH: .. BOILER HVAC LANDSCAPE /IRRI6: X PROTECTIVE SI6NL:
GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDIA OTHR: ..
HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL 0 SYSTEMS: 1
Owner: --------- Contractor: --- TOTAL FEES:$ 5282.21
FOUR D CONSTRUCTION CO FOUR D CONSTRUCTION This permit is subject to the regulations contained in the
PO BOX 1577 PO BOX 1577 Tigard Municipal Code, State of Ore. Specialty Codes and all
BEAVERTON DR 97075 BEAVERTON OR 97075 other applicable laws. All work will be done in accordance
with approved plans. This permit will expire if work is
Phone B: 590-0805 Phone 0: 590 -0805 not started within 180 days of issuance, or if the work is
Reg 0..: 000710 suspended for more than 180 days. ATTENTION: Oregon law
- requires you to follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth in OAR 952-001 -0010 through OAR 952-001 -0080. You may obtain copies of these rules or
direct questions to OUNC by calling (503)246 -1987.
REQUIRED INSPECTIONS -
Erosion 844 -8444 Post /Beam Mechan Electrical Servi Gas Line Insp Electrical Final
Grading Inspecti Crawl Drain /Back Electrical Rough Insulation Insp Mechanical Final
Footing Insp PLM /Underfloor Framing Insp Rain drain Insp Plumb Final
Foundation Insp Mechanical Insp Shear Wall Insp Water Service In Building Final
Post /Beam Struct Plumb To Out Low Voltage Appr /Sdwlk Insp — i
Issued By: g. 1 .- -- Permittee Signature: . _` __ i i /
+++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ y+ + + ++ + + + + + + + ++
Call 639 -4175 by 7:00 p.m. for an inspection needed the next business day
CITY OF TIGARD Residential Buildin Permit A lication PlanChg'ck - X -ogl
9 PP Recd By , •
13125 S'W HALL BLVD. Additions or Alterations Date Recd -11
TIGARD, OR 97223 Single Family Detached or Attached (Duplex) Date to P.E. ir-9
V 503 - 639 -4171 D ate to DST a��t
,..
F 503 - 684 -7297 / ?C° � ermit # P 7 oo5-3
Print or Type •,,,- 1; Calledi2 "RR 9 g 8,.,4 r
Incomplete or illegible applications will not be accepted 9aoirE- Pry il►eM4cr
Name of Project ►3 Name s ant?? - c'e; !,
Job ,� p2 PA/ `?'h�4cai
Address Site Address C U o V ! 57 9 Architect M� Address
11P7, - 7 - Qe_ / /LLCM: //IDS" w, /'
Name Cyit �State Zip Phone
M ili Address Na
Owner
}?. (7, /�JX A� 77 ox/ R0 14e..-Z.L. Ci /State Zi Phone En Mailing/Address
/Address
City/State Zip alone
N ame
General ` P02�'�9y� 972/6 U5V-4.?92
Contractor �0yy `i' 0 ,- ,agiP - r Describe work New .Addition 0 Alteration 0 Repair 0
Mailing Address to be done:
Prior to permit Additional Description of Work: f... , . 1
issuance, a copy City/State Zip Phone // JV w
of all licenses •
are required if Oregon Const. Cont. Board Exp. Date PROJECT
expired in COT Lic.#
database VALUATION $ ) 7 /L
database �� 3 7 �— 00 - m
Mechanical Name NEW CONSTRUCTION ONLY: $'c /( a/
Sub - gp.c /Az7, i�-E,/17'`_ //)y Sq. Ft. 2 Sq. Ft, Garage
Contractor Mailicfg Address
Prior to permit 95,E ? � Gc) �/ � 9R( Sr Indicate the restricted energy installation by the electrical
issuance, a copy City/State Zip hone subcontractor in the followin areas
of all licenses --,--/ y/.1 /t 9 7 2.23 6.20.z-6413 Restricted Audio /Stereo '
are required if Oregon Const. Cont. Board Exp. Date Energy System Alarms
expired in COT Lic. # // . 7 Installations - 'Vacuum ,/Irrigation
database (O 6,5 / System System
Plumbing Name � r (check all that Other:
me
Sub- C 9L cP
� 24-&41 Ng apply)
Contractor Mailing Address Corner Lot YES le Flag Lot YE,S NO
9 (check one) (check one)
/ S92 _c, • S / 1' ,4- u---e..- Has the Subdivision Plat recorded? N/A > ES NO
Prior to permit City/State Zip Phone
issuance, a copy 1// LLSgo72a ei 7/23 6 1,L O - ,23 //
of all licenses are Oregon Const. Cont. Board Exp. Date
required if Lic.# 9 R
expired in COT / / 0 I hearty acknowledge that I have read this application, that the
database Plumbing Lic. # Exp. Date information given is correct, that I am the owner or authorized agent
of the owner, and that plans submitted are in compliance with
24i- ill/ Pe Ore. • ,4St.•eI,, .
Name Si - / • .• �� ► - gen Date
Electrical 7 0 12.eierS ��e ce7 /� !Lf-'i i Z- - 9'
Sub- Mailing Address Co ��ct Person = i e Phone #
�,� V if off' 70- oa'as
Contractor ....s s' ? .S, N c? l/ ,4 v /
City/State Zip Phone
Prior to permit �7 _
issuance, a copy 0 Z 7 9 22/ 4- / 7 4' FOR OFFICE USE ONLY:
of all licenses are Oregon Const. Cont. Board Exp. Date Plat #: Ma /TL #:
required if Lic.# 934, / / / 664 -- b
expired in COT
database Electrical Lic. # Exp. Date g b acks: Zone: K q . S Sol,��: /�
3 y.2 3 0-. T7 �\(�/
Electrical S pr Lic. # Exp. Date a Engi eering Ap Planning Approval: TIF:
((� �� 1 d ;'$ -1 I is \dsts \forms\sfaddalt.doc 11/20/98
01/10/2000 Activities for Case #: MST99 -00053
2:25:51 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA005 Application received 02/04/1999 DRA RECD GEO 02/08/1999
MSTA008 Permit Created 02/08/1999 GEO DONE GEO 02/08/1999
MSTA010 Check for prd. restrict. 02/08/1999 GEO DONE GEO 02/22/1999 Plat map not recorded at intake.
Parcel restrictions to be
checked at post review.
MSTA012 Plans routed to Plans Examiner 02/08/1999 GEO SENT GEO 02/08/1999
MSTA026 Plans approved by Pln Examiner 02/18/1999 RT PASS BT2 02/19/1999
MSTA030 Reviewed plans routed to DSTS 02/19/1999 RT PASS BT2 02/19/1999
MSTA032 DST Post - Review Completed 02/22/1900 GEO DONE GEO 02/22/1999 Plat map not recorded at time
of intake. Parcel restrictions to
be checked at post review.
There is a 20' SSE easment
along the west property line.
MSTA155 Development conditions met GEO 02/08/1999
MSTA700 Erosion 844 -8444 GEO 02/08/1999
MSTA703 Grading Inspection BT2 02/18/1999 14% SLOPE
MSTA705 Footing Insp 02/26/1999 KS FAIL KBS 03/01/1999 #-1- remove soft material form
ftgs & maintain min; of thre
inches clearance under bars
MSTA706 Foundation Insp 03/11/1999 KS PASS KBS 03/12/1999
MSTA710 Post/Beam Structural 04/09/1999 WDJ FAIL AKJ 04/11/1999 1) Insulate ducts where missed
2) Provide gussetts on posts
3) Posts over 4' long require
gussetts on both sides and
lateral bracing
4) Duct work has not been
completed
5) Double joist missing on
upper level center of east side
6) Bndging or blocking missing
where shown on plan,upper
level
MSTA711 Post/Beam Mechanical 04/09/1999 WDJ FAIL AKJ 04/11/1999 See post and beam struc
MSTA713 Crawl Drain /Backwater valve 07/09/1999 RB PART AKJ 07/11/1999
MSTA717 PLM /Underfloor 04/08/1999 GS PART AKJ 04/08/1999 Post and beam plm of lower
floor level only pass
MSTA720 Mechanical Insp 06/30/1999 LN PART AKJ 06/30/1999 1) water heater not installed
2) support fact. made duct off
rafters at mstr bdrm
3) completely block top of
chases
4) maintain 1" clearance at B
vent at garage
do not cover
Page 1 of 4
01/10/2000 Activities for Case #: MST99 -00053 •
2:25:51 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA722 Plumb Top Out 07/09/1999 MS PASS AKJ 07/11/1999 2nd Insp this date
MSTA723 Electrical Service 06/30/1999 CD PASS AKJ 06/30/1999
MSTA724 Electrical Rough In 06/30/1999 CD PASS AKJ 06/30/1999
MSTA725 Framing Insp HOLD BT2 06/11/1999 NO FRAMING INSPECTION
TO BE MADE UNTIL
SPRINKLER SYSTEM HAS
BEEN APPROVED
MSTA726 Shear Wall Insp GEO 02/08/1999
MSTA7.28 Low Voltage GEO 02/08/1999
MSTA735 Gas Line Insp 06/30/1999 LN PASS AKJ 06/30/1999
MSTA740 Insulation Insp 08/03/1999 LN PASS AKJ 08/03/1999 secure insul behind insert lower
level
MSTA752 Rain drain Insp 03/18/1999 TLP PASS TLP 03/18/1999
MSTA761 Water Service Insp 03/31/1999 TLP PASS AKJ 03/31/1999
MSTA765 APpr /Sdwlk Insp GEO 02/08/1999
MSTA790 Electrical Final 11/08/1999 BP PASS VT 11/08/1999 final - pass
light missing
MSTA795 Mechanical Final 12/14/1999 KBS FAIL KBS 12/15/1999 #-1- see bldg final this date
MSTA797 Plumb Final 11/09/1999 MS FAIL DGW 11/10/1999 No water
MSTA799 Building Final 08/05/1999 GS NOTE KBS 10/05/1999 sprinkler sys backflow
prevention device requires
testing prior to bf
MSTA080 (F) Ready to issue 02/22/1999 GEO PASS GEO 02/22/1999
MSTA097 Issue electric signature form 03/02/1999 JMT RECD JT 03/02/1999
MSTA095 Issue plumbing signature form 02/25/1999 JMT RECD JT 02/25/1999
MSTA092 (F) Issue combination permit 02/22/1999 B PASS BON 02/22/1999
MSTA705 Footing Insp 03/02/1999 RC PASS ROC 03/02/1999 UFER APP
MSTA706 Foundation Insp 03/19/1999 KS PASS AKJ 03/21/1999 Damp proofing
MSTA704 Sewer Inspection 03/31/1999 TLP PASS AKJ 03/31/1999
MSTA752 Rain drain Insp 04/08/1999 04/08/1999 04/08/1999 GS PART No Hold AKJ 04/08/1999 Partial interior RD's at 2 rear
comers of house to penetration
of foundation at no west corner
and approx 13'6" of interior RD
behind garage wall
Sump pump on site at No east
• corner but not connected and
no crawl drains in
MSTA710 Post/Beam Structural 04/14/1999 04/14/1999 04/14/1999 WDJ PASS No Hold AKJ 04/14/1999
Page 2 of 4
01/10/2000 Activities for Case #: MST99 -00053
2:25:51 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA711 Post/Beam Mechanical 04/14/1999 04/14/1999 04/14/1999 WDJ PASS No Hold AKJ 04/14/1999
MSTA727 Exterior Sheathing Insp 05/28/1999 TLP PASS No Hold AKJ 05/31/1999
MSTA720 Mechanical Insp 07/11/1999 07/11/1999 07/09/1999 RB FAIL No Hold AKJ 07/11/1999 see framing 7/9/99
MSTA725 Framing Insp 07/11/1999 07/11/1999 07/09/1999 RB FAIL No Hold AKJ 07/11/1999 framing insp shall be contingent
upon sprinkler app
Do not insulate
1) Upstairs top level:
a) add rafter support for 1 plate
marked
b) enclose mech chase
c) seal hole in b vent connector
d) insulate duct at wall to garage
e) bedrm level support rafters in
attic 24" oc over spanned at top
of stairs
f) add stud support for ridge
posting in mstr bdrm
g) enclose b vent lid w/ in chase
off m. bath
2) Main level:
a) strap plates where marked
beams to plate, etc
• b) enclose lid off den- dead
space
3) Lower level:
a) enclose lid to fireplace chase
b) fireplace gas conn not
hooked up to fireplace
c) enclose furred out wall lid
and horizontal 10' intervals
d) block return air floor cavity
MSTA722 Plumb Top Out 07/11/1999 07/11/1999 07/09/1999 RB FAIL No Hold AKJ 07/11/1999 no test
MSTA770 Misc. Inspection 07/22/1999 07/22/1999 No Hold DST 07/22/1999 Fire protection inspection. Fee
paid 7/22/99 (Bon)
MSTA725 Framing Insp 07/25/1999 07/25/1999 07/23/1999 TLP PASS No Hold AKJ 07/25/1999
MSTA720 Mechanical Insp 07/25/1999 07/25/1999 07/23/1999 TLP PASS No Hold AKJ 07/25/1999
MSTA797 Plumb Final 11/10/1999 11/10/1999 11/10/1999 MRS PASS No Hold VT 11/10/1999
Page 3 of 4
01/10/2000 Activities for Case #: MST99 -00053
2:25:51 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA799 Building Final 12/15/1999 12/15/1999 12/14/1999 KBS FAIL No Hold KBS 12/15/1999 #-1- need final erosion control
app
#-2- post insulation cert
#-3- support gas piping @
furnace water heater
#-4- protect sprinkler riser from
freezing also need backflow
device tested
. #-5 -range not functional
#-6- insulate door jambs @
upper storage als o crawl
access door
#-7- provide access to crawl (tall;
#-8- sway brace post @ ext
decks
MSTA795 Mechanical Final 01/02/2000 01/02/2000 12/30/1999 KS PASS No Hold AKJ 01/02/2000
MSTA799 Building Final 01/02/2000 01/02/2000 12/30/1999 KS PASS No Hold AKJ 01/02/2000
MSTA960 (F) Issue Cert. of Occupancy 12/30/1999 KS DONE No Hold JMT 01/10/2000
•
Page 4 of 4
•