Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
• CITY OFTIGARD MASTER PERMIT ,.� ; ��j DE V E LOPMENT SERVICES PERMIT # • MST98 -0482 . II. 13125 SW HaII Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 12 / 14/9B PARCEL: 1S135AD -05100 SITE ADDRESS... : 1 0705 SW SITKA ST SUBDIVISION -TRENT TERRACE ZONING: R -12 BLOCK LOT •001 JURISDICTION: TIC Remarks: Path I. - -- -- - - BUILDING - - - - -- -- - - - -- - - - - - -- REISSUE: STORIES • 2 FLOOR AREAS- -- BASEMENT...: 0 sf REQUIRED SETBACKS - - -- REQUIRED - -- -- CLASS OF WORK.:NEW HEIGHT • 22 FIRST • 510 sf GARAGE • 348 sf LEFT • 18 SMOKE DETECTRS: Y TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 710 sf FRONT • 20 PARKING SPACES: 2 TYPE OF CONST.:SN DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 5 OCCUPANCY 6RP.:R3 BDRM: 3 BATH: 3 TOTAL : 1220 sf VALUE-8: 91347 REAR • 15 — PLUMBING — -- -- -- SINKS • 1 WATER CLOSETS.• 3 WASHING MACH..: 1 LAUNDRY TRAYS.• 0 • RAIN DRAIN ft: 100 TRAPS • 0 • LAVATORIES • 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 1i SF RAIN DRAINS: 1 CATCH BASINS..: 0 TUB /SHOWERS...: 2 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0 OTHER FIXTURES: 0 - - - - -- -- - - - -- - - -- MECHANICAL - -- - - - - - -- - -- FUEL TYPES FURN (100K ..: 1 BOIL /CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1 6AS FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES • 0 GAS OUTLETS...: 1 -- -- -- - - - - -- - - - -- ELECTRICAL — — - -- - -- -- RESIDENTIAL UNIT— — SERVICE /FEEDER -- —TEMP SRVC /FEEDERS— — BRANCH CIRCUITS — — MISCELLANEOUS - -- — ADD'L INSPECTIONS - 1 1,4, ' , SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 2 201 - 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR C1R: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF HM /SVC /FDR: 0 601 - 1000 amp.: 0 601 +amps -1 ;;s v: 0 MINOR LABEL -10: 0 1m+ amp /volt.: 0 - - - - -- -- PLAN REVIEW SECTION — ------- - - - - -- Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.:• > 600 V NOMINAL: CLS AREA /SPC 0CC: — -------- - - - - -- ELECTRICAL - RESTRICTED ENERGY - - - - - -- — ---- - - - - -- A. SF RESIDENTIAL- — - -- B. COMMERCIAL -- - -- - - -- AUDIO b STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: 0TH: :: BOILER HVAC LANDSCAPE /IRRI6: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: MAC DATA /TELE COMM.• NURSE CALLS • TOTAL 1 SYSTEMS: 0 Owner: -------- - - - - -- - - ---- Contractor: ----------------------------- TOTAL FEES :$ 4758.36 KIMCO PROPERTIES, LTD KIMCO PROPERTIES LTD This permit is subject to the regulations contained in the 22060 SE 442ND AVE 22060 SE 442ND AVE Tigard Municipal Code, State of Ore. Specialty Codes and all SANDY OR 97055 SANDY OR 97055 other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is Phone 0: 668 -7075 Phone 0: 668 -7075 not started within 180 days of issuance, or if the work is Reg A..: 110832 suspended for more than 180 days. ATTENTION: Oregon law - ---- --- -- - - - - -- - -- - - - - -- - requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952- 001 -0010 through OAR 952- 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503)246 -1987. REQUIRED INSPECTIONS — - - - - -- Erosion 844 -8444 Crawl Drain /Back Electrical Rough Insulation Insp Mechanical Final Footing Insp PLM /Underfloor Framing Insp Rain drain Insp Plumb Final • Foundation Insp Mechanical Insp Shear Wall Insp Water Service In Building Final Post /Beam Struct Plumb Top Out Low Voltage Appr /Sdwlk Insp Post /Beam Meehan Elec 'cal Servi Gas Line Insp Electrical Final Issued By: Permittee Signature: + + + + + + + + + ++ + ++ ++++++++++++ + + + + + + + + + + + + + + ++ + + + + + + + + + + + + + ++ ++ •+ + + + + + + + + + ++ Call 639 - 4175 by 7:00 p.m. for an inspection needed the next business day CITY OF TIGARD Residential Building Permit Application Plan Check# A2 -64/2 13125 SW HALL BLVD. New Construction Recd By 4' TIGARD, OR 97223 Sin g le Famil y 3 Detached Date Recd i —? Date to P.E. /off 1" V 503 - 639 -4171 Date to DST / ?- -9 al' F 503 -684 -7297 7 j ermit# M5T98' 05'81, . Print or Type C alled iedg9 k $ is "-- Incomplete or illegible applications will not be accepted S / `�' � 5 P 9 PP P SuJ/e 98- U a 3 Name of Project Lo-r _. r ..__ Name / Job — TRENT "TERRPQE 5uat» gl5)Or1 NEIL 7HCAERSor Address Site Address Architect Mailing Address 16X65 sdeJ . 5 a - KA ST, 9991 SW. la 1.9.1h/ Sr• 205 Name City /State • Zip Phone KlmCo ?2oVEg11 S 110 , PorzTr.>x►/ t pR .'72ZS z97 10743 Owner Mailing Address Name 2. 06 0 S . E . 442 N A V E , RON Fu LLFA . City/State Zip Phone Engineer Mailing Address /" SA/VP/ , CR .970s� 66s -707s IZ6 0 Nv .� WELSH zx,vL General Name City/State Zip Phone Contractor Ks rnWO 1Rb1 fl" LIP , Pot iCI ition 0 �l 71�`f S33 o � Describe work New% Addition Alteration 0 Repair O Mailing Address 14P to be done: SAIGG FAR9r1/ lf'rou Prior to permit 2.2., 06,0 S ,E,4--1- 2 A-ue. - Additional Description of W rk: ! 67f, - -- issuance, a copy City /State Zip Phone /A 20 56X{a9 L. -- 819- . 3 5 g - e,4/ : 3 i . s's b, of all licenses 5 /4/�ID y� a? . 97 053 �� 7C r _ _ ,� are required if Oregon o st. Cont. Board Exp. Date PROJECT expired database OT Lic.# / ! 0 83 2 . I -to-11 VALUATION 7, - -- I '/.3y Mechanical Name -,4r NEW CONSTRUCTION ONLY: Sub - 4 EN6/LA'L. F21f?N/%C.� f A/2 Ca6, Sq. Ft. House: Sq. Ft. Garage Contractor Mailing Address /NC. /020 S>' 3 '/3 i= Prior to permit ? , 0 , O)c 35 Indicate the restricted energy installation by the electrical issuance, a copy City/State Zip Phone subcontractor in the following areas TWA • - of all licenses CL4C,(/MYlA5 (}2.?7015 bS6 Restricted Audio /Stereo are required if Oregon Const. Con Board Exp. Date Energy System Alarms expired in COT Lic.# database 0010 /O`1 _ Installations Vacuum Irrigation Plumbing Name orrefi : System System (check all that Other: Sub- MIXIE M X fine& Ri1ivavy apply) Contractor Mailing Address I Number of Units in Building Unit Number Designation A 0, BOA POI / Prior to permit / City /State Zip Phone GHQ Has the Subdivision Plat recorded? N/A YES NO issuance, a copy e,AiVbB 14.417013 A &G - 7 /O - X of all licenses are Oregon Corid. Cont. Board Exp. Date illelsolilempliemm required if Lic.# Q vz p� expired in COT 11‘0965 TJ / 20oo I hearty acknowledge that I have read this application, that the database Plumbing Lic. # Exp. Date information given is correct, that I am the owner or authorized agent 3 - 3 if, 1-N.-.7b7 of the owner, and that plans submitted are in compliance with Name Oregon State laws. Si�g atur: % • /Agent Date rn Electrical tiZA aC),tG. I- / 7 `2 Sub- Mailing Address Conte Pers Name Phone # Contractor pQ, bo ,(p3 NF /L 77- IoqE2SOAJ O 7- (73 City/State Zip Phone Mi.. gt9- &O& Prior to permit Op a- FOR OFFICE USE ONLY: issuance, a copy 41,,,� 5011 eel 7®27 /f 2 7 Plat #: Map/TL #: of all licenses are Oregon Const. Cont. Board Exp. Date. / /�— `/7 y' 1E/3 s'n6 - 9 s required if Lic.# .� )y Se tb acks: � Zone: expired in COT I/s 7 % / ' G 0'� . /e -fez_ database Electrical Lic. # Exp. Date Engineering Approval: Planning Approval: TIF: • 3 4 - 2 SC /0-If - 9q -73: L. .zAir /Z/gAr - Electrical Supervisor Lic. # Exp. Date if 3'73 /0 - 1 -200 • i:\dsts\forms\sfd-new.doc 10/26/98 • „ FORM No. 668 EASEMENT FUR r' a '' / t COPYRIGHT 1996 SIEVENS.NESS LAW rUUUSHING CO.. i 0 LAta C', 9720 J � / H NS .. v STATE OF OREGON SS r'. £ 7 /'/7 ' weR' County of Washington ' I EASEMENT FOR .yam'`• ►A.• I I, Jerry R l-ranson;.;Dirbctor of Assess- ;s. I i ment and: Jaxation Ex,Officio County nt i Clerk for,said:county, io certify that Between the within. insfrurnent.of writing was received ay ! ii il .0,// p� and recorded _iri boob "of.; r ecords of said a � i E� S county. i , •L `;f ” ' �, ,......_ ... . i ?cry cf9 -S 4 1 6 0 1:::": r Ai 7 ,... - ■ I 4 4‹. ':'1* ''?.. y70.5, , - - 4 ........,..,..„..: :._...- ge I And SPACE RESER\ . ^� U- FOR RECORDER'S L = • Jerry R. H of `',Assessment'and Taxation, Ex- !. Wiz' (f,--S wP c, : , . - - .- Officio County Clerk 1 Z.,4 e ��—. P d 1 7 Doc 98076314 ty I After reco , return to (Name, Address y): � IR' , , 4 �S Rect: 212664 46.00 I I ; . a !' $,ti7'�S- . 07/14/1998 03:13:11pm I I _LET -• - ePs� � 4 I ,7 ?_J i - -- . , ..... ,ut i THIS .B REEM T made anfl entered in this _/ >1- day of 7 'v ,19 by and 11 11 etween - -- - 4 o e.)c -_ / - -A - c� / , a ereinafter called the first party, and � IZ.t�' � �� _ ___A _3_. , hereinafter called the second party, WITNESSETH: / 0.r.,/ ; WHEREAS: The first party is the record owner of the following described real property in i45 w �o'f li c eg, ounty, State of Oregon, to -wit: I1 G0 t 1 / 67 i I' - t C e2 L 01./7 P. 2. - s 41 Ar 1. yvi X - 4? 74...<_ 651--i C5re I I' • ° .'and the second party is the record owner of the following described real property in that county and state, to -wit: i ' TO = o�Z Z .0 a o —n-- r' 4, � / ; r r4, c �� r< dr is t, / l Q N ,_ 1: 1.4./.44(.4 I .8I I. E P and th'o parcels of real estate adjoin one another; and the parties desire to grant to each other an easement and right to use a Q! § certain now existing or about to be constructed along and upon a portion of each parcel; a l ¢ NOW, THEREFORE, in consideration of each party's granting to the other an easement hereinafter described, and other valu- I able consideration paid to other, the receipt of which is hereby a knowledged: I First party conveys to second party a perpetual easement for 'lc driuewey purposes, along and upon that portion of first party's property described as follows, to -wit: • I S c & c X LI , 6- 4- „ a 0 , 9: 14- 4 ,_ c. ,, `/ I I t , 7 1- : ,. /, r ©1...v i-- e :76 e gg 4 71- , I i . (OVER) -- /-ww—Lit-- — • 8/23/99 Activities for Case #: MST98 -00482 1:11:33 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA005 APPlication received 12/2/98 GEO RECD DLH 12/3/98 MSTA008 Permit Created 12/3/98 DLH DONE DLH 12/3/98 MSTA010 Check for prcl. restrict. 12/3/98 DLH DONE DLH 12/3/98 MSTA012 Plans routed to Plans Examiner 12/3/98 DLH SENT DLH 12/3/98 MSTA026 Plans approved by Pln Examiner 12/7/98 RT PASS BT2 12/7/98 MSTA030 Reviewed plans routed to DSTS 12/7/98 RT PASS BT2 12/7/98 MSTA032 DST Post - Review Completed 12/8/98 JSD PASS JSD 12/8/98 Need sub - contractors identified before issuance. DLH MSTA155 Development conditions met DLH 12/3/98 MSTA700 Erosion 844 -8444 12/28/98 CPB PASS RB 12/28/98 MSTA705 Footing Insp 12/17/98 RC FAIL J'H 12/18/98 No USA approval, 2nd notice. $15.00 assessed. Need street signs posted. MSTA706 Foundation Insp 12/31/98 TLP PASS TLP 12/31/98 MSTA710 Post/Beam Structural 1/13/99 GS PASS GES 1/13/99 MSTA711 Post/Beam Mechanical 1/13/99 GS PASS GES 1/13/99 MSTA713 Crawl Drain /Backwater valve 1/12/99 TLP PASS TLP 1/12/99 MSTA717 PLM /Underfloor 1/13/99 GS PASS GES 1/13/99 MSTA720 Mechanical Insp 3/8/99 RC FAIL ROC 3/9/99 BATH FANS NOT CONNECTED ALL DUCTS IN UNCOND. SPACE MUST BE INSUL MSTA722 Plumb Top Out 3/8/99 RB FAIL RB 3/8/99 Water Service approval Req'd. Nail plate(s) missing. Soffit plumbing in garage. Vehicle barrier req'd. Mid -guide straps missed. Nail flange of shower enclosures. No test on DWV. INSPECTION TERMINATED ! MSTA723 Electrical Service 3/8/99 BRP PASS B*P 3/9/99 MSTA724 Electrical Rough In 3/8/99 BRP PASS B *P 3/9/99 Check panel schedule on final. Excessive box setback, noted. MSTA725 Framing Insp 3/8/99 RC FAIL ROC 3/9/99 1. PROVIDE STUDS WHERE OVERBOARD FOR PLUMBING AND MECH. 2. SYTRAP WALLS WHERE OVERBOARD FOR PLUMBING 3. FRAME SOFFIT FOR MECH AND PLUMBING IN GARAGE 4. PROVIDE BEARING FOR GLULAM WHERE NOTCHED Page 1 of 3 8/23/99 Activities for Case #: MST98 -00482 • 1:11:33 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA726 Shear Wall lnsp 2/22/99 RB PASS RB 2/23/99 MSTA728 Low Voltage DLH 12/3/98 MSTA735 Gas Line Insp 3/8/99 RC PASS ROC 3/9/99 TAG # 340578 MSTA740 Insulation Insp DLH 12/3/98 MSTA752 Rain drain Insp 1/12/99 TLP PASS TLP 1/12/99 MSTA761 Water Service Insp 1/19/99 RB FAIL RB 1/19/99 No Test! Provide safe access to rear of property. Inspection terminated. MSTA765 APPr /Sdwlk lnsp NOTE J'H 12/27/98 private street (Tract A of Trent Terrace) MSTA790 Electrical Final 8/6/99 BRP FAIL AKJ 8/8/99 kitchen wall plate not flat on surface panel schedule is not in compliance, words misspelled, not complete MSTA795 Mechanical Final 8/6/99 PG FAIL AKJ 8/8/99 see bldg final 8/6/99 MSTA797 Plumb Final 8/6/99 MS PASS AKJ 8/8/99 spouts need to be caulked MSTA799 Building Final 8/6/99 PG FAIL AKJ 8/8/99 1) provide a listed connector above water heater to B vent 2) provide install intruction for decorative gas appliance 3) remove debris from crawl attach fallen insul 4) first stair tread isn't uniform in depth with other treads, provide less than 3/8" difference 5) seal all penetrations at gas pipe meter base and wires at ext of gar 6) maintain min 6" clearance between finish grade and found wall 7) provide adequate protection for plywood siding where patio slab compromises its integrity MSTA080 (F) Ready to issue 12/8/98 JSD PASS DLH 12/14/98 Must complete application with • sub - contractor info and have sub - contractor licenses on file. jsd On 12/14/98 received all subcontract information. DLH MSTA092 (F) Issue combination permit 12/14/98 DLH DONE DLH 12/14/98 MSTA095 Issue plumbing signature form 12/21/98 JMT RECD JT 12/21/98 MSTA097 Issue electric signature form 12/21/98 JMT VOID JT 3/5/99 Page 2 of 3 8/23/99 Activities for Case #: MST98 -00482 1:11:33 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA705 Footing Insp 12/16/98 LN FAIL J *H 12/17/98 1. No USA approval. 2. Recall for Thursday. 3. Provide lap for rebar at center wall. Ufer tagged okay. MSTA005 APPlication received 12/16/98 LN PASS J *H 12/17/98 Previously approved. MSTA780 «REINSPECTION» 12/28/98 RC PAID DST 12/28/98 Footing errors not corrected (no USA approval). See inspection from 121798. $15.00 . assessed. Paid $15.00 • reinspect fee on 12/28/98. DLH MSTA705 Footing Insp 12/28/98 RB PART RB 12/28/98 Fees paid this date- RB. Report dtd. 12 -16-98 LN, and 12 -17 -98 RC- issues completed. MSTA097 Issue electric signature form 3/5/99 JMT RECD JT 3/5/99 MSTA720 Mechanical Insp 3/9/99 RB FAIL RB 3/10/99 See Framing this date. MSTA725 Framing Insp 3/9/99 RB FAIL RB 3/10/99 Exhaust venting still disconnected. Plumbing top out issues are still incompleted. Framing corrections from report dtd. 3 -8 -99 RC were completed, but unable to pass due to . mechanical and plumbing issues. MSTA722 Plumb Top Out 3/9/99 RB FAIL RB 3/10/99 Water Service failed 1 -19 -99 RB. Nail plate where missed. Secure tub /showers. No test on DWV. Leak noted. MSTA725 Framing Insp 3/12/99 RB FAIL RB 3/15/99 Plumbing top-out issue. DWV- no test (thru roof). MSTA722 Plumb Top Out 3/12/99 RB FAIL RB 3/15/99 DWV- no test. MSTA720 Mechanical Insp 3/12/99 RB PASS RB 3/15/99 MSTA720 Mechanical Insp 3/16/99 RB PASS RB 3/17/99 As per RC report dtd. 3 -8-99. MSTA725 Framing Insp . 3/16/99 RB PASS RB 3/17/99 As per RC report dtd. 3 -8-99. MSTA722 Plumb Top Out 3/16/99 RB PASS RB 3/17/99 MSTA761 Water Service Insp 3/30/99 GS PASS AKJ 3/30/99 MSTA790 Electrical Final 8/15/99 8/15/99 8/13/99 BRP PASS No Hold AKJ 8/15/99 MSTA799 Building Final 8/15/99 8/15/99 8/13/99 TLP PASS No Hold AKJ 8/15/99 MSTA795 Mechanical Final 8/15/99 8/15/99 8/13/99 TLP PASS No Hold AKJ 8/15/99 MSTA960 (F) Issue Cert. of Occupancy 8/13/99 TIG TLP DONE No Hold JMT 8/23/99 Page 3 of 3 . CITY OF TIGARD BUILDING INSPECTION DIVISION MST c fg — d1/6 7 Z 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 2 �Q BUP Date Requested 3 - 0- (/ AM PM BLD Location I n0 S Sl Suite MEC Contact Person O i I Ph 7 R' -- )' -- (.D - 2(D3 PLM Contractor Ph R(t'2774) SWR i Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN • Crawl Drain Inspection Notes: Slab SIT Post & Beam / Ext Sheath /Shear .Q L. ; a/ Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler 4 ` / Co(ee. 2N s rea 2 / //e 9 L Fire Alarm �^P5 �C�D� cc � Susp'd Ceiling Roof Misc: 4 PART FAIL P •' :ING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANIaj.> ( 7 Post & Beam Rough In Gas Line Smoke Dampers mat PART FAIL RICAL Service Rough In UG /Slab Low Voltage • Fire Alarm Final PASS PART FAIL SITE r\ Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA Approach /Sidewalk Date 1 / 3/ 97 Inspector / � Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.