Permit „ OF TIGARD MASTER PERMIT
1 � A 4 DEVELOPMENT SERVICES PERMIT # MST98- 05'Z'7
lI �. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 01/11/99
PARCEL: 1S135AD -05400
SITE ADDRESS,..:10780 SW SITKA L
SUBDIVISION -TRENT TERRACE ZONING: R -12
BLOCK LOT -004 JURISDICTION : C--77Q
Remarks: PATH I: New single family dwelling w /attached garage
-- — BUILDING -- - - - - -- ----- -- - - - -
REISSUE: STORIES : 2 FLOOR AREAS - - - -- BASEMENT...: 0 sf REQUIRED SETBACKS - - -- REQUIRED------- -
CLASS OF WORK. HEIGHT • 20 FIRST • 520 sf GARAGE • 428 sf LEFT • 5 SMOKE DETECTRS: Y
TYPE OF USE...:SF FLOOR LOAD : 40 SECOND...: 710 sf FRONT • 33 PARKING SPACES: 2
TYPE OF CONST.:5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 5
OCCUPANCY GRP.:R3 BORN: 3 BATH: 3 TOTAL - - -: 1230 sf VALUE..$: 93511 REAR : 25
•
-- --- - - - - -- - PLUMBING - -- -- — --
SINKS : 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 100 TRAPS • 0
LAVATORIES • 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 100 SF RAIN DRAINS: 1 CATCH BASINS..: 0
TUB /SHOWERS...: 2 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
- -- - - - - -- ------------------ — MECHANICAL — ------------------------------ -
FUEL TYPES — FURN (100K ..: 1 BOIL /CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1
GAS FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WODDSTOVES • 0 GAS OUTLETS...: 1
- - -- - -- - ---- -- ELECTRICAL — - - - -- -- --- - --
- - RESIDENTIAL UNIT -- — SERVICE /FEEDER— —TEMP SRVC /FEEDERS— — BRANCH CIRCUITS— -- MISCELLANEOUS -- - -ADD'L INSPECTIONS--
1m SF OR LESS: 1 0 - 203 alp..: 0 0 - 203 amp..: 0 W /SVC OR FOR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 2 201 - 400 alp..: 0 201 - 403 amp..: 0 1st W/O SVC /FOR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0
LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 asp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0
MALE HM /SVC /FOR: 0 601 - 1 amp.: 0 601 +asps -1 m v: 0 MINOR LABEL -10: 0
l'om+ amp /volt.: 0 -- - - - - -- PLAN REVIEW SECTION - - - -- - - - ------ —
Reconnect only.: 0 ) =4 RES UNITS..: SVC /FOR) =225 A.: ) 603 V NOMINAL: CLS AREA /SPC OCC:
- -------------- - - - - -- - - -- ELECTRICAL - RESTRICTED ENERGY ----- - - - - -- --
A. SF RESIDENTIAL ------------------ B. COMMERCIAL — - - - - -- --
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: OTH: :: BOILER • HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGMA
GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: ::
HVAC DATA /TELE COMM.: NURSE CALLS TOTAL 8 SYSTEMS: 0
Owner: - - - -- Contractor: -------- --- - -- TOTAL FEES:5 4768.56
KINCO PROPERTIES, LTD KIMCO PROPERTIES LTD This permit is subject to the regulations contained in the
22060 SE 442ND AVE 22060 SE 442ND AVE Tigard Municipal Code, State of Ore. Specialty Codes and all
SANDY OR 97055 SANDY OR 97055 other applicable laws. All work will be done in accordance
with approved plans. This permit will expire if work is
Phone 8: 668 -7075 Phone 8: 668 -7075 not started within 180 days of issuance, or if the work is
Reg 8..: 110832 suspended for sore than 180 days. ATTENTION: Oregon law
- ------------------------------------------- -- -- requires you to follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth in OAR 952- 001 -0010 through OAR 952 001 -0280. You may obtain copies of these rules or
direct questions to OUNC by calling (503)246 -1987.
- -- - - - - -- REQUIRED INSPECTIONS - - - - - -- -- -- ---- --
Erosion 844 -8444 Crawl Drain /Back Electrical Rough Insulation Insp Mechanical Final
Footing Insp PLM /Underfloor Framing Insp Rain drain Insp Plumb Final
Foundation Insp Mechanical Insp Shear Wall Insp Water Service In Building Final
Post /Beam Struct Plumb Top Out Low Voltage Appr /Sdwlk Insp
Post /Beam Mechan Electrical Servi Gas Line Insp Electrical Final
Issued By: Permittee Signature: I ,L/,
+ + + + + + + + + + ++ + -+++++++++++ +++++++++++ + ++ ++t+ + +++++ ++ + ++++ -+ +,14+++++++++++
Call 639 -4175 by 7:00 p.m. for an inspection needed the nex business day
CITY OF TIGARD Residential Building Permit Application Plan Check # /s '57
13135 SW HALL BLVD. New Construction Additions or Alterations Recd By -
Date Recd _(p - / S
TIGARD, OR 97223 Single Family Detached Date to P.E. /A. -
V 503- 639 -4171 Date to DST /,2.2) — 9S//z
F 503 -684 -7297 Vr 40 Permit # /W '$ -CYO?
Print or Type 6vr ( Called /,? -R.z -
Incomplete or illegible applications will not be accepted GFir V // A,1;softie_
NV /G 771oi,2Solt-
Name of Project - ‘674. >v r Name DE 5./A5./A.)5 �
Job AN u S 77�"�r �
Address Site Address // Architect Mailing Address
/0 7R0 £.1,v, $ii ,4 Tl A- c��u- �fq Se�- GviGSrna Zv`D
G $Ip` C taj Ph�on
Zip ,,
Namg, /�/D >l�s LT P- I t0e � • f 7Zl� #2`17�76' 3
Owner Mail W 0. �' Address Z ` Name &Cac. ,045/6A1 f //U
Engineer Mailing Address
City/State Zip Phone g ./ 5 O N. Al. /Ut 5)4 DR,
SAND Y I ea, 1 ! -7 0 u 0, 5- City /State Zip Phone
General Name peg i i W ZZ1 533 5-7 7,5-- Contractor 4; i oleo f a s, (, 1 2 - Describe work New�C Addition 0 Alteratioh 0 Repair 0
Mailing Address to be done:
Prior to permit S. 2 06 5 •I% . 442 No /‘, Additional Description of W
issuance, a copy City/State Zip Phone !0"1 _1 )r /Z3o = $S _ 011.1 /4f k) .5 q Le FA /y / ‘
of all licenses 5A- p if ous SS /,(4- 7O7�� X = 7 8�
are required Oregon t. Cont. Board Exp. Date P ROJECT ) I -3 5//..------;
expired in COT Lic.# - /
database // K3 2.. / -/0 -�°f VALUATION ,
Mechanical
Name NEW CONSTRUCTILY:
Sub - 6606441.., c4.00)ACL f i4/,eapt,0, Sq. Ft. House: Sq. Ft. ara e
Contractor Mailing Address /We. /ai30 ..5! 1
Prior to permit Po • go lc 3.5"- Indicate the restncted energy installation by trical
subcontractor in the following areas
issuance, a copy City/State Zip Phone Restricted Audio /Stereo
of all licenses /(,for(,4Gp p 4 e1 7o(s ( - 6. 2 1,,
are required if Oregon Const. Cont. Board Exp. Date A Energy System Alarms
expired in COT Lic.# Installations Vacuum Irrigation
database 0E3169 lo 91 System System
Plumbing Name (check all that Other:
Sub- M IKE Pict. Pii'/(E Maine apply)
Contractor Mailing Address / Corner Lot YES NO _,. Lot YES N% I I
A a Box 8o / (check one) (check one)
H as the Subdivision Plat recorded? N/A YES. NO
Prior to permit City /State Zip Phone d
issuance, a copy ...cpg• QR 7D13 26,6,' 7tSZ Solar Compliance
of all licenses are Oregon Cond. Cont. Board Exp. Date (Calculation Attached) it)//4
required if Lic.#
expired in COT U6%5 O S D Q - Z1 - I hearby acknowledge that I have read this application, that the
database Plumbing Lic. # Exp. Date information given is correct, that I am the owner or authorized agent
of the owner, and tha • lans submitted are in compliance with
3-3 R 31 Oregon Stater s
^
Name : ign.. re �• • •� . /A ' Da
Electrical E C. N- Aid., � � - /Z / ff
/ham Q'L � % tact ' erson N. - n � - PHone #
Sub- Mailing Address I £ - G � 2
Contractor p , p , is 0 (o (03
� EA- 77 3
FOR OFFIC' SE ONLY:
Ciity /State Zi � Phone Plat #: Ma /TL#:
Prior to permit PY CSI DS % ( / /I (O S0 - I (p2 9 11 47 /,/3 ,9J 05
issuance, a co
S • acks: 02 Solar;
Z o
r N
of all licenses are Oregon Const. Con Board Exp. Date • / _ /
required if Lic.#
expired in COT I/ S 333 I -2000 Engi eering Approval: Planning Approval: TIF:
database Electrical Lic. # 3.- Exp. Date Th Mt /2G /1
4z SG IO--I -`1
4-395-5- —
to- l -loci /a- /.7 -4
1 CaEN. ycp
I:SFREM1.DOC (DST) 8/11/98
, FORM No 668 - EASEMENT FOR i t Y' / COPYRIGHT I96 STEVENS.NESS LAW PI,BUSnar+G cO .. Ur_C
POH r U/ ST2L'A -- - -
.. •• STATE OF OREGON SS itv; •
f c. 7L1 7/7 - WQR County of Washington
EASEMENT FOR .-'= t':I,.
I, Jerry R. ;Ha Director, of Assess- ;s.
ment and •'Taxation "and Ex- Officio County nt
`' Clerk for said do certify that
Between the within of writing was received :ty
/�- / - � '` L • S and recorded .in book of, records of said at
�r; !_ � county.
,i vo OS L� ° Q PA � _ '- _ ine
And S PACE RESER∎ ;, D
: / _ FoR : •; J
I Jerry R: Hinson, Director of ,
L-� �` � y._ ! �� RECORDER'S l r
.> d.� L. ,A sses s ment and Taxation, Ex
C7 f /• r _ .�' �� j Offici County Clerk t
Z...,..4 . d - Li., P.. Q, 77 01 y
Doc : 98076314
After reeordln$, return to (Name, Address Zip):
�1 r1 /, , Rect: 212664 46.00
�;e c ''‘,7--•-• 4t-5 . - 07/14/1998 03: 13:1lpm
77 0 r " .,r,,ty.
o THIS A REEM NT made an entered in this / U "` 2 day of 7 -' r , 19!_ , by and ,
etween - e I. AL_ Q1e.,k -- / _..4 -5 ,
o hereinafter called the first party, and �� /.3. A �1'_
, hereinafter called the second party, VJITNESSETH: /
E ; WHEREAS: The first party is the record owner of the following described real property i n '� `� ``� � /
NJ , - ounty, State of Oregon, to -wit:
n t
at '/ y
u r_L1 /
m
a
ai g
° f ! Ta nd the second party is the record owner of the following described real property in that county and state, to -wit:
- —
E . J --/ ^j - r —
E iZ O i" , Z D ,' ( /-'J 4,-1--- / .Z r r4- c C /7i/ dg. /(
g : E c- i_/ .-tr .__,P)" zvzl -� L 1 1 n-/ T?/ /✓ c—S � ' � D _ .)!-- `� 0.,t/ ,
• CIQ
.
E P- and thewo parcels of real estate adjoin one another; and the parties desire to grant to each other an easement and right to use a
! ¢ certain now existing or about to be constructed along and upon a portion of each parcel;
W NOW, THEREFORE, in consideration of each party's granting to the other an easement hereinafter described, and other valu-
;; able consideration paid tai each other, the receipt of which is hereby a knowledged:
�•, First party conveys to second party a perpetual easement for mobile driuway purposes, along and upon that portion. of
'1; 'first party's property described as follows, to -wit:
1
i' 5 E - E E.,k' 4 . ‘ ; /7 4 ,,, a . , 4 2 7 9-- 4 ,_ < i
i. 7& .
.
1 (OVER)
•
—_ —__ — —_ - -__ -- — _
�• r
LAND TECH, INC.
8835 SW CANYON LANE
SUITE 402
PORTLAND, OR 97225
PHONE: (503) 291 -9398 FAX: (503) 291 -1613
CIVIL ENGINEERING - SUBDIVISION PLANNING & DESIGN- LAND SURVEYING - CONSTRUCTION SURVEYING
EXHIBIT A
•
A 10.00 foot wide easement for the purposes of providing power to a light pole over and across
those tracts of land described as Lots I and 2 of the duly recorded plat of "Trent Terrace"
situated in the 1V.E. '/ of Section 35, T.1S., R.1 W., W.M., City of Tigard, Washington County,
Oregon, being more particularly described as follows:
A 10.00 foot wide easement situated 5.00 feet either side of the property line separating said Lots
1 and 2 and terminating on each end where the side lines intersect S. W. Hall Blvd. to the west
and S. W. Sitka Court to the east.
REGISTERED
PROFESSIONAL
LAND SURVEYOR
ORE ON
JANUARY 19, 1993
EDWARD KING PHELPS
25E5
E*Plrce- I Z. - t -98
1
•
z
• A (' ��
/
REGISTERED
PROFESSIONAL
LAND SURVEYOR
ciA-ita1)?
EXHIBIT B
OR
E
JANUARY 19, 1993
EDWARD KING PHELPS
2586 �
r /1( S
LOTS 1 AND 2 OF "TRENT �
TERRACE" SI TUA TED IN THE r►�� Q
N.E. 1/4 OF SECTION .35,�� i
TS., R./W, W.M., CITY v
•,P IV
OF TIGARD, WASHINGTON �
COUNTY, OREGON
Q
S W. SITKA COURT o
7 0.
5.00 i cv
r LOT 7 c
� 10.00' WIDE POWER JO' 30
LOT 2 r - I LINE EASEMENT FOR
r
4 PROVIDING POWER TO
r 7 STREET LIGHT
r
D
HALL BO U LEVA R
S. W No
1165
• CAR.
W FQRk No. 96i - BARGAIN AND SALE DEED - STATUTORY FORM (Individual Grantor). sTEVENS-NESS LAW Pt/HUSHING CO. PORTLAVO OF 9729A__
I NS r _�
STATE OF OREGON,
I County of } ss.
1 certify that the within instrument
Grantor's Name and Address was received for record on the day
I of , 19 at
o'clock .M., and recorded in
i book /reel /volume No. on page
Grants'', Name and Address
SPACE RESERVED and /or as fee /file /instru-
ARer recording, return to (Na Address, Zip
o� �-- � FOR ment /microfilm /reception No.
1J cs RECORDERS USE Records of said County.
Witness my hand and seal of County
affixed.
Until requested otherwise, send all tart statements to (Name, Address, Zip):
NAME TITLE
By , Deputy.
BARGAIN AND SALE DEED — STATUTORY FORM
(INDIVIDUAL GRANTOR)
J. BRADLEY PIHAS , Grantor,
conveys to - _
J. BRADLEY PIHAS , Grantee.
the following real propcny situated in WASHINGTON County, Oregon, to -wit:
I
A 10 FOOT WIDE PRIVATE STORM DRAINAGE EASEMENT; 5 FEET ON EACH SIDE OF THE
al. COMMON PROPERTY LINE BETWEEN LOTS 2 AND 3 OF TRENT TERRACE SUBDIVISION.
I SAID EASEMENT IS FOR THE BENEFIT OF LOTS 1 -7 OF THE TRENT TERRACE SUBDIVISION.
i
1
1
!I
li
I•
1
1 I
I I (IF SPACE INSUFFICIENT, CONTINUE DESCRIPTION ON REVERSE)
The true consideration for this conveyance is $ (Here, comply with the requirements of ORS 93.030.)
1
1
Dated this __ day of __ , 19 27
i; THIS INSTRUMENT WILL NOT ALLOW USE OF THE PROPERTY DESCRIBED IN 1.,_____
THIS INSTRUMENT IN VIOLATION OF APPLICABLE LAND USE LAWS AND REGU-
LATIONS. BEFORE SIGNING OR ACCEPTING THIS INSTRUMENT, THE PERSON
■ ACQUIRING FEE TITLE TO THE PROPERTY SHOULD CHECK WITH THE APPRO-
PRIATE CITY OR COUNTY PLANNING DEPARTMENT TO VERIFY APPROVED USES
J AND TO DETERMINE ANY LIMITS ON LAWSUITS AGAINST FARMING OR FOREST
PRACTICES AS DEFINED IN ORS 30.930.
STATE OF OREGON, County of ___ - �/ 4/ �) sss.
This instrument was acknowledged before me on __ 1� '1/ , 19Y
b .�' ' l � /F —LZ7 / / _ jam ��
OFFICIAL SEAL r t ,
I '� CriiSTCPHER INATSON Y r�� �
l L "-pi hOThRYPUBLIC- OREGON - ! f
I e - COMMISSION HO.05:039 r: Notary Public fo/• gon
II? C0•.'INISSION EXPIRES JUNE 15, 2000 . c. —7.— � a� 4" 8
I
t .., - .;; ; - -, .:.. -,..:. s.� My commission exp
, 1 ' ft RM No. 961 - BARGAIN AND SALE DEED - STATUTORY FORM (Individual Grantor). STEVENS-NESS LAW vUl3USHING CO-. PCRTLANO OR 9r2G■
NS . C AS.
JI1
STATE OF OREGON,
County of . l• ss.
I certify that the within instrument
•
Grantor's Name and Address was received for record on the __..___ day
of , 19 a(
o'clock .M., and recorded in
I
Gramw'sNameandAddrau book /reel /volume No. on pave
SPACE RESERVED and /or as fee /file /instru-
Atter recording, return to (Ham., Address, Zip): • FOR ment /microfilm /reception No.
RECORDER'S USE
Records of said County.
Witness my hand and seal of County
I affixed.
I Until requested otherwise. send all tax statements to (Name, Address, Zip):
i
I NAME TIRE
j By .. .. , Deputy.
BARGAIN AND SALE DEED - STATUTORY FORM
1 (INDIVIDUAL GRANTOR)
I
I ! J. BRADLEY PIHAS , Grantor,
conveys to
J. BRADLEY PIHAS , Grantee.
1 the following real property situated in WASHINGTON County, Oregon, to -wit:
II
II GRANTOR BEING THE ORIGINAL DECLARANT AND CURRENT OWNER OF LOTS 1 -7 OF
TRENT TERRACE, EXECUTES THIS DEED TO RELEASE THE EASEMENT AS DEPICTED
! ON THE PLAT OF TRENT TERRACE OVER LOTS 2 AND 3 FOR THE BENEFIT OF LOTS
1-7. EASEMENT IS FURTHUR DESCRIBED ON PAGE 2 OF PLAT AS NOTE NO. 4.
i
I
I
. I
I
I 1
11
I
� I (IF SPACE INSUFFICIENT. CONTINUE DESCRIPTION ON REVERSE)
' The true consideration for this conveyance is $ . (Here, comply with the requirements of ORS 93.030.)
-- -..
!I
I
Dated this / 7771L
day of _ 4,4A- , 19.1
,! THIS INSTRUMENT WILL NOT ALLOW USE OF THE PROPERTY DESCRIBED IN a cis
I; THIS INSTRUMENT IN VIOLATION OF APPLICABLE LAND USE LAWS AND REGU-
Ir LATIONS. BEFORE SIGNING OR ACCEPTING THIS INSTRUMENT, THE PERSON
II ACQUIRING FEE TITLE TO THE PROPERTY SHOULD CHECK WITH THE APPRO-
j PRIATE CITY OR COUNTY PLANNING DEPARTMENT TO VERIFY APPROVED USES
AND TO DETERMINE ANY LIMITS ON LAWSUITS AGAINST FARMING OR FOREST
PRACTICES AS DEFINED IN ORS 30.930.
! AZ a 4 7 I /
i e
STATE OF OREGON, County of ss.
�o
This instrument was acknowledged before , 19?
I by • -- L --_ f-- '2_1
CHRLSTCI H_R ‘7:.7.39t4 1
{, ,- NOTARY Pet:LIC On0;1 - -- - -
\,� uiS3!O110. ..)50.. y E Notary Public f = I gon
CO:;
; IJYCOLIJISSI' flEEXPIR 13.2000 H My commission expires G � W / - e
L
7/19/99 Activities for Case #: MST98 -00507 .
12:07:30 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA005 Application received 12/15/98 GEO RECD GEO 12/17/98
MSTA008 Permit Created 12/17/98 GEO DONE GEO 12/17/98
MSTA010 Check for prcl. restrict. 12/17/98 GEO DONE GEO 12/17/98
MSTA012 Plans routed to Plans Examiner 12/17/98 GEO SENT GEO 12/17/98
MSTA026 Plans approved by Pln Examiner 12/21/98 RT PASS BT2 12/21/98
MSTA030 Reviewed plans routed to DSTS 12/21/98 RT PASS BT2 12/21/98
MSTA032 DST Post - Review Completed 12/22/98 GEO DONE GEO 12/22/98
MSTA155 Development conditions met GEO 12/17/98
MSTA700 Erosion 844 -8444 GEO 12/17/98
MSTA705 Footing Insp 1/13/98 RC PASS ROC 1/14/99 UFER APP.
MSTA706 Foundation Insp 1/27/99 TLP PASS TLP 1/28/99
MSTA710 Post/Beam Structural 2/9/99 RB FAIL RB 2/9/99 Post/Beam plumbing approval
req'd. INSPECTION
TERMINATED. NOTE: Gusset
post/beam connections at joint.
Support plate behind furnace
plenum. Spread vapor barrier
over exposed ground. Remove
wood debris from crawl space.
Support flex duct off of ground.
Vapor barrier req'd for metal
duct insulation.
MSTA711 Post/Beam Mechanical 2/9/99 RB FAIL RB 2/9/99 See structural this date.
MSTA713 Crawl Drain /Backwater valve 2/9/99 RB FAIL RB 2/9/99 Low point drain does not
• appear to be draining properly -
Water holding at throat of
• back -water valve.
MSTA717 PLM /Underfloor 2/9/99 MS PASS MRS 2/9/99 water service in crawl needs to
be insulated need nail plates
where you penetrate the mud
seal
MSTA720 Mechanical Insp 4/12/99 KS FAIL AKJ 4/12/99 See framing notes
MSTA722 Plumb Top Out 3/29/99 GS PASS AKJ 3/29/99 1) Possible leaks at hall bath
lay saw T and check at mst
bath saw T of tub vent to WC
vent
MSTA723 Electrical Service 4/13/99 BRP PASS AKJ 4/13/99
MSTA724 Electrical Rough In 4/13/99 BRP PASS AKJ 4/13/99
MSTA725 Framing Insp 4/12/99 KS FAIL AKJ 4/12/99 1) Need elec cover approved
prior to framing /mech insp
Page 1 of 3
7/19/99 • Activities for Case #: MST98 -00507
12:07:30 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA726 Shear Wall Insp 3/12/99 RB FAIL RB 3/15/99 1. Strap window at nook/block
same. 2. Sheathing missed
upstairs. 3. Add HD strap per
plans. 4. Nail wing walls of
garage 3 -inch ctrs on header.
Once cover allowed, apply
2nd sheathing to interior side.
Note: OK for other phase work
• and inspections- to be
re- checked at framing.
MSTA728 Low Voltage 4/13/99 BRP PASS AKJ 4/13/99
MSTA735 Gas Line Insp 4/12/99 KS FAIL AKJ 4/12/99 See framing notes
MSTA740 Insulation Insp 4/16/99 KS PASS AKJ 4/18/99 Insulate void at water piping in
garage
MSTA752 Rain drain Insp GEO 12/17/98
MSTA761 Water Service Insp 4/2/99 GS FAIL AKJ 4/5/99 Not ready
MSTA765 Appr /Sdwlk Insp 7/6/99 MH N/A AKJ 7/6/99 private rd
MSTA790 Electrical Final 7/6/99 CD PASS AKJ 7/6/99
MSTA795 Mechanical Final 7/6/99 KS FAIL AKJ 7/6/99 see bldg final notes 7/6/99
MSTA797 Plumb Final 7/6/99 MS FAIL AKJ 7/6/99 no hot water, require pressure
reducers at the meter'
Reading over 100 psi
MSTA799 Building Final 7/6/99 KS FAIL AKJ 7/6/99 1) need usa final permit
2) seal at plenum at garage wall
3) gas fireplace not working
4) seal under mudsill in garage
5) provide underfloor access
6) seal penetrations on exterior
of structure
plm final failed 7/5/99
MSTA080 (F) Ready to issue 12/22/98 GEO PASS GEO 12/22/98
MSTA092 (F) Issue combination permit 1/11/99 DLH DONE DLH 1/11/99
MSTA095 Issue plumbing signature form 1/20/99 JMT RECD JT 1/20/99
MSTA097 Issue electric signature form 1/20/99 JMT VOID JT 3/5/99
MSTA710 Post/Beam Structural 2/11/99 RB PART RB 2/11/99 Seal water main insulation.
Cover ground w/ vapor barrier.
MSTA711 Post/Beam Mechanical 2/11/99 RB PART RB 2/11/99 See P/B Structural this date.
MSTA713 Crawl Drain /Backwater valve 2/11/99 RB PART RB 2/11/99 Reversed grade w/ storm line to
street.
MSTA717 PLM /Underfloor 2/11/99 RB PART RB 2/11/99 See P/B Structural this date.
MSTA097 Issue electric signature form 3/5/99 JMT RECD JT 3/5/99
Page 2 of 3
7/19/99 Activities for Case #: MST98 -00507
12:07:30 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA726 Shear Wall Insp 3/15/99 RB 3/15/99
MSTA726 Shear Wall Insp 3/16/99 RB PASS RB 3/17/99
MSTA095 Issue plumbing signature form 3/26/99 JMT RECD JT 3/26/99 change of contractor
MSTA725 Framing Insp 4/13/99 4/13/99 4/13/99 RC FAIL No Hold AKJ 4/13/99 No app plans on site
MSTA720 Mechanical lnsp 4/13/99 4/13/99 4/13/99 RC PASS No Hold AKJ 4/13/99
MSTA725 Framing lnsp 4/14/99 4/14/99 4/14/99 KS FAIL No Hold AKJ 4/14/99 1) Pos conn glulam to header at
garage
2) Soffit plm and mech at garag(
3) Provide full bearing under
glulam at kitchen and pos conn
4) Truss clips missed
5) Provide insul shield at B vent
and secure also ins supply
ducts at attic voids
6) Gas piping pt test 24 psi for
20 min
MSTA720 Mechanical lnsp 4/14/99 4/14/99 4/14/99 KS FAIL No Hold AKJ 4/14/99 See framing notes
MSTA735 Gas Line lnsp 4/14/99 4/14/99 4/14/99 KS PASS No Hold AKJ 4/14/99
MSTA725 Framing Insp 4/18/99 4/18/99 4/16/99 KS PASS No Hold AKJ 4/18/99
MSTB781 Water Service lnsp 4/20/99 4/20/99 4/20/99 GS PASS No Hold AKJ 4/20/99
MSTA795 Mechanical Final 7/7/99 7/7/99 7/7/99 KS FAIL No Hold AKJ 7/7/99 see bldg final notes 7/7/99
MSTA799 Building Final 7/7/99 7/7/99 7/7/99 KS FAIL No Hold AKJ 7/7/99 1) seal plenum at floor wall
intersection
2) fireplace still not working
3) dry pack at mudsill in garage
4) clean and remove debris,
lumber underfloor. repair or
replace vapor barrier at
exposed earth underfloor.
MSTA797 Plumb Final 7/8/99 7/8/99 7/7/99 MS PASS No Hold AKJ 7/8/99
MSTA795 Mechanical Final 7/8/99 7/8/99 7/8/99 KS PASS No Hold AKJ 7/8/99
MSTA799 Building Final 7/8/99 7/8/99 7/8/99 KS PASS No Hold AKJ 7/8/99
MSTA960 (F) Issue Cert. of Occupancy 7/8/99 TIG KS DONE No Hold JMT 7/19/99
Page 3 of 3
CITY OF TIGARD BUILDING INSPECTION DIVISION MST q
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
k BUP
Date Requested 7 -• 'q ' AM PM BLD
Location I en b 0 Si 4 I� G • Suite MEC
1 `
Contact Person Q,l , Ph 2.5n - f ' 7(3 PLM p�
Contractor Ph 2I I ' L O( 7 SWR 0 - 03s
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain
Crawl Drain Inspection Notes:pLd few „ / J SGT
Slab kg SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc: i� ✓� _
Final
P, PART FAIL
AfAlaWKAPIV—
Post & Beam
Under Slab
Top Out
Water Service
Rai Drains
4115
PART / � �
M ANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
0 1(1
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill/Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of required before next ins ection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: . v [ ] Unable to inspect - no access
ADA
Approach /Sidewalk
Other Date Inspector r/ "a
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST OSO7
• 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
q� BUP
Date Requested s - / AM PM x BLD
Location ONO 51 1L � a Suite MEC
Contact Person / Ur(�t, Ph 7) -1 -Con/ PLM
Contractor Ph 2 f 7 z ' 7603 SWR
UIL Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes: f Y
Slab lG( QA \. SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
PART FAIL
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS FAIL
Po earn
Rough In
Gas Line
Smoke Dampers
J_ PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Otheoach /Sidewalk Date 7 � ''5 ' ' Inspector , s Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST 9 8 QOS'07
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUD
Date Requested �� p -(// AM PM BLD
Location I h 7 SO i't Suite
Q te MEC
Contact Person / �-r.c I Ph 1S / - (,x 7 PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes `
Slab �(d� 'I �- SIT
Post & Beam
Ext Sheath /Shear
Int Sheath/Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler �� ;i AM
Fire Alarm ��i
Susp'd Ceiling f•�/ ��
M sc: . IKG=IFia r w
Final / rl,
P ART FAIL
LU
Pos[B Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
R•'. Drains
• PART FAIL
ANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ I Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk
Other Date Inspector Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.