Loading...
Permit CITY OF TIGARD MASTER PERMIT A li DEVELOPMENT SERVICES PERMIT # : MST98 -0265 l DATE ISSUED: 08/12/98 --- 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639-4171 PARCEL: 19134DA —DMO25 SITE ADDRESS...:11390 SW THUNDER TERR SUBDIVISION -DAKOTA MEADOWS ZONING: R -12 PD BLOCK LOT :025 JURISDICTION: TIG Remarks: New SFA - Path 1 - Special Inspection for rough grading - Registered survey required to establish property lines BUILDING — — REISSUE: STORIES • 3 FLOOR AREAS — BASEMENT...: 8 sf REQUIRED SETBACKS— REQUIRED - CLASS OF WORK.:NEW HEIGHT : 34 FIRST : 623 sf GARAGE • 462 sf LEFT : 0 SMOKE DETECTRS: Y TYPE OF USE...:SFA FLOOR LOAD • 40 SECOND...: 842 sf FRONT • B PARKIN SPACES: 2 TYPE OF CONST.:5N DWELLING UNITS: 1 FINB5MENT: 842 sf RIGHT • 0 OCCUPANCY GRP.:R3 BORN: 2 BATH: 3 TOTAL------: 2387 sf VALUE..$: 163130 REAR : 0 PLUMBING SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 1' TRAPS • 0 LAVATORIES • 3 DISHWASHERS...: 1 FLOOR DRAINS..: 8 SEWER LINE ft: 1i. SF RAIN DRAINS: 2 CATCH BASINS..: 0 TUB /SHOWERS...: 2 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1'. BCKFLW PREVNTR: 1 GREASE TRAPS..: 8 OTHER FIXTURES: 0 — MECHANICAL -- FUEL TYPES FURN (108K ..: 0 BOIL /CMP ( 3HP: 1 VENT FANS • 3 CLOTHES DRYERS: 1 6AS FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 0 OTHER UNITS...: 1 MAX INP.: 2508N BTU FLOOR FURNACES: 0 VENTS • 1 WCODSTOVES • 0 GAS OUTLETS...: 1 ELECTRICAL — RESIDENTIAL UNIT— — SERVICE /FEEDER— —TEMP SRVC /FEEDERS— — BRANCH CIRCUITS— ----MISCELLANEOUS--:— --ADD'L INSPECTIONS - 1%v. S= OR LESS: 1 8 - 200 amp..: 0 0 - 200 amp..: 0 W/SVC OR FOR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 508SF.: 4 201 - 408 amp..: 0 281 - 408 amp..: 0 1st W/O SVC/FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 8 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF HM /5VC /FDR: 0 681 - 1w. amp.: 0 601 +amps- 1Y• v: 0 MINOR LABEL -18: 0 1080+ amp /volt.: 0 PLAN REVIEW SECTION Reconnect only.: 8 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 608 V NOMINAL: CLS AREA /SPC GEC: ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO A STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: OTH:X .. BOILER • HVAC LANDSCAPE /IRRI6: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: .. HVAC • DATA /TELE COMM.: NURSE CALLS • TOTAL 0 SYSTEMS: 8 Owner: — -- - Contractor: TOTAL FEES:$ 4455.46 BEACON HOMES INC BEACON HOMES This permit is subject to the regulations contained in the 9508 SW 125TH AVE 9580 SW 125TH Tigard Municipal Code, State of Ore. Specialty Codes and all BEAVERTON OR 97a BEAVERTON OR 97'x other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is Phone B: 524 -1999 Phone 4: 524 -1999 not started within 180 days of issuance, or if the work is Reg D..: 000707 suspended for more than 180 days. ATTENTION: Oregon law — - - -- requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0810 through OAR 952-801 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503)246 -1987. REQUIRED INSPECTIONS -- — Erosion Control Plm /undslb Insp Plumbing Top Out Shear Wall Insp Appr /Sdwlk Insp Mechanical Final Grading Inspecti Electrical Servi Framing Insp Firewall Insp Smoke Detector Building Final Footing Insp Electrical Rough bas Line Insp Rain Drain Insp Fire Alarm Insp Foundation Insp Mechanical Insp Gas Fireplace Water Line Insp Electrical Final Slab Insp Low Voltage Insulation Insp Water Service In Plumb Final / Issued By: Permittee Signature: L.. + + + ++ + + + + + + ++ ++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ + + + + ++ + + + + + + + + + + ++ Call 639 -4175 by 7:00 p.m. for an inspection needed the next business day 1 _qL . Plan Check # CITY OF TIGARD . Residential Building Permit Application' Recd By n 13175'SW1ALL BLVD. New Construction Additions or Alterations . - Date Recd ( -L - / TIGARD, OR 97223 , Single Family Detached or Attached (Duplex) . ' _ ` Date to P.E. -Z� . V503-639-4171 / Date to DST 7 %8 Permit # F503-684-7297 = T - 0 1 6 } � � �'' OlS Print or Type - cooed o � az.�.. Incomplete or illegible applications will not be accepted -. . t e i sy v ' • BUILDING 1 — Lot, 2.5 • - = Name of Project Name -- Job.• DAKOTA MEADOWS PETER'MAGARO ARCHITECTURE Archi Mailing Address Address site Address 10570 SW Cit D �'. - 1.1390 SW _Thunder Terrace Name " City/State Zip Phone' Beaverton 97008 579 - BEACON HOMES, INC. ' Name Owner Mailing Address . DOVE ENGINEERING 9500 SW 125th Aenue Engineer Mailing Address City /State Zip Phone g 4914 Oakr Rd. Beaverton 97008 524 =1999 General Name City/State - Zip Phone Lake Oswego 97035 697 -5926 Contractor BEACON HOMES, INC. . Describe work New Addition 0 Alteration 0 Repair 0 Mailing Address to be done: . Prior to permit . 9500 SW 125th. 'Avenue Additional Description of Work: issuance,acopy City/State Zip Phone attached - single- family dwellings... - of all licenses Beaverton 97008 524 -1999 - are required if Oregon Const Cont Board Ezp. Date ' _ PROJECT - expired in COT Lic. #' 70782 • - 12/17/98 • VALUATION $ 146,966.@® ' database _ Mechanical Name ' _ - • ' NEW CONSTRUCTION ®NLY: Sub- - MUEHE ' QUALITY HEATING -Sq. Ft House: Sq. Ft. Garage - • • • Contr Mailing Address 1833 800 ' _ Prior to permit PO Box 9 _ Corner Lot YES NO Flag Lot YES NO issuance, a copy City/State Zip Phone (check one) X (check one) . X of all licenses West Linn 97068 598 -0966 Restricted Audio /Stereo Burglar are required if Oregon Const. Cont. Board Exp. Date expired in COT Lic.# 50096 3/5/99 Energy System Alarm database Installation Garage Door HVAC - Plumbing - Name . _ Opener. yes Systems X Sub CUSHMAN FAMILY PLUMBING , (check all that - Other. Contractor .- Mailing Address apply) 4535 SE 35th ,Place - - Will the electrical subcontractorwireforall YES , - restricted energy installations? • Prior to permit City/State Zip Phone - Has the Subdivision Plat recorded? N/A YES NO issuance, a copy Portland 97202 775 -4472 of all licenses are Oregon Const Cont. Board • ' Exp. Date , X required if ' Lic.# 106842, ' 6/7/99 - Solar Compliance . - expired in COT - (Calculation Attached) database .. Plumbing Lic. # Exp. Date - I hearby acknowledge that I have read this application, that the. 2 6 — 5 6 4 P B 6/30/98 - information given is correct, that I am the owner or authorized Name agent of the owner, and that plans submitted are in compliance with Oregon State laws. N, l/ Electrical _ BEAR ELECTRIC , INC . Sigr> * f Own dA erit MOV Sub- Mailing Address V U Contractor PO Box 389 Contact Per Na P #I City/State Zip Phone Peter 'Ku syk . 524 -1999 Prior to pemSit FOR OFFICE USE ONLY: issuance, a copy ' Donald, OR 97020 678 -135 Plat #: vwF a Map/TL#: of all licenses are Oregon Const Cont Board Exp. Date lenko V\0( p % . 6( q -- 2,s' required if Lic.# 2 0 919 . 2/20/00, S ' Zon Solar. expired in COT )0;4, Ihi's — _ ( r database • Electrical Lic. # Exp. Date } tl�l 24 -107C Engineering App o a I: Planning Approval: TIF: . 10/1/98 - I:SFREM.DOC ff, t: 5/7/99 Activities for Case #: MST98 -00265 11:22:50 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTB005 Application received 6/25/98 B RECD BON 6/29/98 MSTB008 Permit created 6/29/98 B DONE BON 6/29/98 MSTB010 Check for prcl. restrict. .BON 6/29/98 MSTB012 Plans routed to Plans Examiner 6/29/98 B SENT BON 6/29/98 MSTB030 Reviewed plans routed to DSTS 7/28/98 RDP APPR RDP 7/28/98 MSTB032 DST Post Review Completed 7/29/98 JSD PASS JSD 7/29/98 MSTB700 Erosion Control Insp 844 -8444 8/17/98 USA PASS RB 8/19/98 MSTB703 Grading Inspection RDP 7/2/98 Special Inspection by Geo_Tech, See soils report MSTB705 Footing lnsp 8/13/98 RB FAIL JT 8/18/98 Registered survey required to establish property lines required prior to footing pour special inspection required for rough grading USA erosion required post address signage not ready MSTB706 Foundation lnsp 8/25/98 RB PART RB 8/25/98 Seismic restaint placement; as per footing layout of previous inspection. NOT INCLUDING INTERIOR FOOTINGS Inn MSTB715 Slab Insp 9/4/98 RB PASS RB 9/4/98 HD's to be installed at later date. MSTB720 Plm /undslb Insp 8/31/98 MS PASS MRS 8/31/98 MSTB723 Electrical Service 12/8/98 CD PASS CD 12/8/98 MSTB724 Electrical Rough -in 12/8/98 CD PASS CD 12/8/98 MSTB725 Mechanical Insp 12/16/98 RB FAIL J *H 12/18/98 Not ready, inspection terminated. MSTB727 Low Voltage BON 6/29/98 MSTB729 Plumbing Top Out 12/1/98 MS PASS MRS 12/2/98 MSTB730 Framing Insp 10/14/98 RB PART RB 10/14/98 3rd floor level - ok to stand upright, but do not close up. 1st level garage wings- ok to close up for shear req'mts. MSTB740 Gas Line Insp 12/18/98 RC PASS J *H 12/20/98 Tag 340564 MSTB741 Gas Fireplace N /AA RB 12/28/98 MSTB745 Insulation lnsp 12/28/98 RB PART RB 12/28/98 Chink windows /doors where lacking proper seal. Protect Hot -water heater from blown -in insulation. Protect water lines in attic. Insulate garage wall to under - stairs. Firestop thru hole penetrations. MECH> ROUGH - Passed 12 -18 -98 RC. Page 1 of 4 5/7/99 Activities for Case #: MST98 -00265 11:22:50 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTB750 Shear Wall Insp 10/1/98 RB FAIL RB 10/1/98 Not ready !!!! MSTB755 Firewall Insp RDP 7/2/98 See City of Tigard Row Housing Policy for details on party wall MSTB775 Rain Drain Insp 8/31/98 MS PASS MRS 8/31/98 MSTB780 Water Line Insp 8/31/98 MS PASS MRS 8/31/98 MSTB781 Water Service Insp BON 6/29/98 MSTB785 Appr /Sdwlk Insp JMT N/A JT 5/7/99 private street MSTB789 Smoke Detector BON 6/29/98 MSTB790 Fire Alarm Insp BON 6/29/98 MS•B796 Electrical Final 3/3/99 CD PASS AKJ 4/1/99 MSTB797 Plumb Final 3/12/99 TLP PASS TLP 3/12/99 MSTB798 Mechanical Final NOTE AKJ 3/23/99 Check mechanical in attic MSTB799 Building Final 3/3/99 CD PASS CD 3/4/99 MSTB080 (F) Ready to issue 7/29/98 JSD PASS JSD 7/29/98 MSTB050 Hold for 8/4/98 DEB HOLD DRA 8/4/98 • Hold pending release from Eng & Pln. Permit back in Bob T's area. MSTB055 Hold Release 8/5/98 DEB DONE KJP 8/5/98 MSTB080 (F) Ready to issue 8/5/98 DEB MEMO DLH 8/12/98 Must pay fee in lieu of undergrounding prior to issuance. Check SUB97 -0002. Fee In -Lieu of Undergrounding $6,517.50 for SUB97 -0002 was paid on 08/12/98. DLH MSTB092 (F) Issue combination permit 8/12/98 DLH DONE DLH 8/12/98 MSTB095 Issue plumbing signature form 8/18/98 JMT RECD JT 8/18/98 MSTB097 Issue Electric Signature Form 8/18/98 JMT RECD JT 8/18/98 MSTB705 Footing Insp 8/18/98 RB PART RB 8/19/98 BUILDING 1 (11370 SW Thunder) 1. Ufer tagged 2. 8 -feet in from curb- to- entire exterior perimeter, except wings at front. 3. Submittal of Geo -tech and Survey reports req'd. 4. PRIOR TO SLAB, an inspection shall be req'd for bearing pads and interior footings. Ufer ground ok for this unit, but not tagged for middle unit <11380> lot 24. Page 2 of 4 5/7/99 Activities for Case #: MST98 -00265 11:22:50 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTB705 Footing Insp 9/4/98 RB PASS RB 9/4/98 Interior footing -ok HD's to be installed at later date. MSTA750 Firewall Insp_ 10/1/98 RB PART RB 10/1/98 2nd floor rock wool at party walls; inner rim and floor decking over party walls- ok, as per plans. MSTB755 Firewall Insp 10/1/98 RB PART RB 10/1/98 2nd floor- rock wool at party . walls; inner rim and floor decking over party wall- ok, as per plans. MSTB755 Firewall Insp 10/14/98 RB PART RB 10/14/98 OK to stand upright. MSTB750 Shear Wall Insp 10/14/98 RB PART RB 10/14/98 Exterior garage wings - ok to close up w/ shear req'mts. MSTB737 Roof Nailing 11/4/98 RC FAIL J *H 11/4/98 Roof not framed as per plans. Resubmit plans for approval. MSTA726 Shear Wall Insp 11/6/98 RB FAIL RB 11/6/98 NOT READY! MSTB750 Shear Wall Insp 11/10/98 WDJ PART WDJ 11/10/98 1. Install horizontal strap at girder truss. 2. Install missing HD2A near stairs in storage area. NOTE:Drywall shear will require inspection OK TO SIDE. MSTB730 Framing Insp 12/11/98 RB PASS J *H 12/15/98 INSPECTION TERMINATED: SEE REPORT IN FILE. , MSTB725 Mechanical Insp 12/11/98 RB FAIL J *H 12/15/98 INSPECTION TERMINATED: SEE REPORT IN FILE. MSTB730 Framing Insp 12/20/98 12/18/98 RC FAIL J *H 12/20/98 not ready MSTB730 Framing Insp 12/20/98 12/28/98 RB PART RB 12/28/98 See insulation this date MSTB740 Gas Line Insp 12/20/98 J *H 12/20/98 MSTB725 Mechanical Insp 12/20/98 12/18/98 RC PASS J *H 12/20/98 MSTB772 Engineered grading final reprt 12/24/98 HAP NOTE AKJ 3/22/99 Carlson approved compaction for pad. See letter of 081998 to file. MSTB755 Firewall Insp 12/28/98 RB PART RB 12/28/98 Between units not complete at this time- ok at gypsum. MSTB755 Firewall Insp 12/30/98 12/30/98 RB PART RB 12/30/98 Garage lid (first layer) and underneath stairs- ok. Wrap beam w/ 2- layers in garage. MSTB760 Gyp Board Insp 12/30/98 NOTE RB 12/30/98 Check underneath stairs and first layer of garage lid. MSTB760 Gyp Board Insp 12/30/98 1/4/99 RB PASS RB 1/4/99 MSTB755 Firewall Insp 12/30/98 1/4/99 RB PASS RB 1/4/99 2ND LAYER LID AND FIREWALL. MSTB798 Mechanical Final 12/30/98 3/23/99 RB FAIL AKJ 3/23/99 see bldg final notes Page 3 of 4 5/7/99 Activities for Case #: MST98 -00265 11:22:50 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By - Updated Notes MSTB706 Foundation Insp 1/19/99 RB RETN RB 1/20/99 RETAINING WALL: Keystone Type- Submit Special Inspection Reports, ie, compaction, drainage, etc. MSTB799 Building Final 3/23/99 RB FAIL AKJ 3/23/99 1) Unable to view attic mechanical 2) Cover cleanouts within wall cavity 3) Contingent to planning approval for conditions of site MSTB798 Mechanical Final 4/1/99 WDJ PASS AKJ 4/1/99 Extend exhaust duct to roof vent or exterior MSTB799 Building Final 4/1/99 WDJ PASS AKJ 4/1/99 MSTB950 (F) Issue Cert. of Occupancy 5/7/99 JMT DONE No Hold JT 5/7/99 • Page 4 of 4 CiTY OF TIGARD BUILDING INSPECTION DIVISION MST 6? -670S 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 Cdl19 BUD Date Requested AM PM BLD Location 1 1 3 Suite MEC Contact Person 4, �J tk& Ph 512- l PLM Contractor Ph SWR cUILDTG ' _ Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation LlQC fi• �� q - i' a (so FPS Ftg Drain SGN Crawl Drain Inspection Notes: • Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear 11� Framing X -inCx `� ?�,J�ia�, 1 [.� G� /L 7ie,•�vT Insulation Drywall Nailing 9-* .Z -'X /L Firewall Fire Sprinkler Fire Alarm Susp'd Ceili Roof Mi . S PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains • Final PASS PART FAIL 4 CHANT Ro ea Rough In Gas Line rSaQoke Ctn. I• ASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line . [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date Y///77 GI Inspector ,Pi►— Ext r// Final PASS PART FAIL DO NOT REMOVE this inspection record.from the job site. CITY OF TIGARD A Program for Inspection Services and/or Material Testing Date: " ,19 "NW- Qij -o 263 City of Tigard: Plan Ck. No.4( amp No.ou¢d11.s Sit No. Project Title: erno filesuCtf)a)$ Address Au- CO +S DA1G4ii It3oo &4 Architect of Record &IM AA/SACO Ph. 511 address: loS?o exrArto4'Pe P. erp'J p Structural Engineer of Record: Ph. address: Geo- Technical Engineer of Record: CAt4.4o"fr sr 46r Ph. X814 - 3 address: Po 1-'6%.4.- - 1 - 16( 0 Ot . Provide the following information for the testing agency chosen to provide inspection services and/or testing. Testing Agency: Ph. Fax. address Geo-Technical Agency: e.AeLs. T � - r - 1 44 Ph. (oJ 13 4o Fax. address it. fap.e ene - — 11c 6 40.4), O. q ?Le t The owner certifies that the above noted Agency has been employed to conduct the special inspections or observations required herein. Signature of Owner Phone No. Date Print name Company name The following is a list of special inspection and/or services required by the 1996 Oregon Structural Specialty Code and Tigard's Municipal Code 14.06.010 through 14.06.040. The special inspections and/or testing services required for this project to be provided by the Testing Agency, Structural Engineer or Geo - Technical Engineer of Record are as follows: • Special Inspectors for the Testing Agency shall be qualified, to the satisfaction of the Building Official, for inspections of the particular type of construction or operation. • Special inspectors shall observe the work assigned herein for conformance with the approved plans and specifications and. submit copies of all inspection reports and. a final signed report in accordance with OSSC. Section 1701.3 to the building official. t• Category Description of Services_ Required Provided By Yes / No 1. Footings adjacent to slopes steeper than 33 -1/3 % OSSC, Section 1806.4 a. Confirm building footings are properly set back from descending slope b. 2. Grading OSSC, Section 3309 a. Regular grading [less than 5,000 cu. yds. but considered unusual] • • Requirements for engineered grading apply. b Engineered grading [exceeds 5,000 cu. yds.] Submit: 1. Geo-technical engineers report and, 2. a engineering geology report. 3. an as -built grading plan and, 4. a final report prepared by the soils engineer and, 5. the final report prepared by the geologist. C. _ - X 3. Fills OSSC, Section 3313 a. Preparation of ground. for fill on slopes exceeding 1 to 5 (20 %) Includes benching and proper termination at the toe of the slope b Acceptance of fill materials C. Compaction of fill material to minimum 90% of maximum density. 13125 SW Hall Blvd., Tigard, OR 97223 [503] 639 -4172 FAX [503] 684 -7297 1:4BLDGSPLINSPI.DOC