Permit -= CITY OF TIGARD MASTER PERMIT
/Go A DEVELOPMENT SERVICES PERMIT • MST98 -0`64
N DATE ISSUED: UED: 08/12/98
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639.4171
PARCEL: 1S134DA —DMO24
SITE ADDRESS...:11380 SW THUNDER TERR
SUBDIVISION -DAKOTA MEADOWS ZONING: R -12 PD
BLOCK LOT -024 JURISDICTION: TI`
Remarks: New SFA - Path 1 - Special Inspection required for rough grading - Registered survey required to establish property lines
BUILDING
REISSUE: STORIES • 3 FLOOR AREAS BAIT...: 0 sf REQUIRED SETBACKS— REQUIRED-- -
CLASS OF WORK:.NEW) HEIGHT • 34 FIRST : 623 sf GARAGE • 462 sf LEFT : 8 SMOKE DETECTRS: Y
TYPE OF 1�...:SFA FLOOR LOAD • 40 SECOND...: 842 sf FRONT : 8 PARKING SPACES: 2
TYPE OF COAST. :5N DWELLING UNITS: 1 FINBSMENT: 842 sf RIGHT : 0
OCCUPANCY GRP.:R3 BDRM: 2 BATH: 3 TOTAL : 2307 sf VALUE..$: 163130 REAR • 0
PLUMBING
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 1v. TRAPS • 0
LAVATORIES • 3 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 1'.' SF RAIN DRAINS: 2 CATCH BASINS..: 0
TUB /SHOWERS...: 2 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1' BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
MECHANICAL
FUEL TYPES----------- FURN (108K ..: 0 BOIL /CAP ( 3HP: 1 VENT FANS : 3 CLOTHES DRYERS: 1
GAS FURN ) =100K ..: 1 UNIT HEATERS..: 8 HOODS • 0 OTHER UNITS...: 1
MAX INP.: 250888 BTU FLOOR FURNACES: 0 VENTS • 1 WOODSTOYES • 0 GAS OUTLETS...: 1
— ELECTRICAL - - - --
- RESIDENTIAL UNIT— — SERVICE /FEEDER— —TEMP SRVC /FEEDERS— — BRANCH CIRCUITS — --- MISCELLANEOUS— --ADD'L INSPECTIONS -
1w. SF OR LESS: 1 0 - 208 amp..: 0 0 - 208 alp..: 0 W /SVC OR FDR..: 8 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 4 201 - 488 amp..: 8 201 - 408 amp..: 8 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 8 PER HOUR • 8
LIMITED ENERGY.: 8 481 - 680 amp..: 0 . 401 - 608 amp..: 8 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0
MANF HM /5VC /FDR: 0 681 - 1w. amp.: 8 601+amps- 1w v: 8 MINOR LABEL -10: 8
1008+ amp /volt.: 8 PLAN REVIEW SECTION
Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC:
ELECTRICAL - RESTRICTED ENERGY
A. SF RESIDENTIAL B. CRCIAL
AUDIO I STEREO.: VACUUM SYSTEM..: AUDIO II STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: OTH:X :: BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIMNL:
GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: ..
HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL B SYSTEMS: 0
Owner: Contractor: TOTAL FEES:f 4455.46
BEACON HOMES INC BEACON HOMES This permit is subject to the regulations contained in the
9508 SW 125TH AVE 9500 SW 125TH Tigard Municipal Code, State of Ore. Specialty Codes and all
BEAVERTON OR 97' BEAVERTON OR 97'.x'.: other applicable laws. All work will be done in accordance
with approved plans. This permit will expire if work is
Phone 0: 524 -1999 Phone 0: 524 -1999 not started within 188 days of issuance, or if the work is
Reg 8..: 008707 suspended for more than 180 days. ATTENTION: Oregon law
requires you to follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth in OAR 952-081-8810 through OAR 952- 001 -8080. You may obtain copies of these rules or
direct questions to OUNC by calling (503)246 -1987.
- REQUIRED INSPECTIONS
Erosion Control Plm /undslb Insp Plumbing Top Out Shear Wall Insp Appr /Sdwlk Insp Mechanical Final
Grading Inspecti Electrical Servi ' Framing Insp Firewall Insp Smoke Detector Building Final
Footing Insp Electrical Rough Gas Line Insp Rain Drain Insp Fire Alarm Insp
Foundation Insp Mechanical Insp Gas Fireplace Water Line Insp Electrical Final
Slab Insp Low Voltage Insulation Insp Water Service In Plumb Final
Issued By: Permittee Signature- •
+ + + + + + + + + + + + ++ +++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + ++ + ++ + + + + + + + + ++
Call 639 -4175 by 7:00 p.m. for an inspection needed the next business day
k• . i— Plan Check #
CITY OF TIGARD Residential Building Permit Application Recd By 0
131' SW HALL BLVD. New Construction Additions or Alterations ' , ' Date Rec'd • L - ZS - '1
TIGARD, OR 97223 Single Family - Detached or Attached (Duplex) ' - D to P.E. G) -.2
V 503 - 639 -4171 /. Date to D T Z 8 Il
F 503 -684 -7297 n C / Permit # I
_ , • ' -- Flint or Type - - ' : called- : - - ' „ < -0151
Incomplete' or illegible applications will not be accepted _ i:1'`
BUILDING 1 -- Lot 24 •
Name of Project , - Name ,— _
Job DAKOTA 'MEADOWS -' - - PETER'MAGARO•ARCHITECTURE -
Address:. site Address . Architect Mailing Address • 10570 SW Ci Dr•,•
11-3 - 80 • S W_:Thuder - ,Terrace`• - .. _
Name City/State Zip , - - Phone
Beaver 97008_ 579 -2421
BEACON HOMES. INC. Name
Owner Mailing Address JEFF DOVE ENGINEERING
9500 SW 125th Avenue Engineer City/State Zip Phone Mailing Address g 4914 0 akr Rd.
Beaverton 97008 524 -1999
General Name City/State - Zip Phone
• Lake Oswego 97035 697 -5926
Contractor BEACON HOMES , INC . • Describe work New b Addition 0 Alteration 0 . Repair 0
. Mailing Address . to be done: • .
Prior to permit 9500' SW 125th Avenue Additional Description of - Work: '
•- issuance, a copy City/State - Zip Phone • attached single- family dwellings.
of all licenses Beaverton 97008 524 -1999 _ .
are required if Oregon Const Cont. Board Exp. Date - . PROJECT - ,
expired in COT Lic.# 70782 .12/17/98 : • VALUATION $ 146,966.60 • - .
database . - •
Mechanical Name . - . NEW CONSTRUCTION ONLY:
Sub- - MUEHE• 'QUALITY . . HEATING • -Sq. Ft. House: Sq: Ft. Garage
Contractor Mailing Address , 1833 - - 800
Prior to permit PO •Box - 9' _ Corner Lot YES NO Flag Lot - YES 'NO
issuance, a copy City/State Zip - Phone (check one) - X (check one) _ X
of all licenses West Linn 97068 5 9 8 - 0 9 6 6 Restricted . Audio /Stereo -Burglar
are required if Oregon Const. Cont. Board Exp. Date
expired in COT Lic.# Energy System Alarm
database 50096 • 3/5/99 Installation - Garage Door HVAC
Plumbing Name - Opener yes Systems X
Sub - . CUSHMAN FAMILY • PLUMBING - (check all that Other. . •
Contractor.. Mailing Address apply)
4535 SE 35th Place . - r WlI the electrical subcontractorwire forall YES , NO
restricted energy installations? - • -
I?nor to permit City/State ' • Zip Phone • • • Has the Subdivision Plat recorded ? - N/A YES NO
lasuance, a copy • Portland- 97 -202 - 775 -4472 -
of all licenses are Oregon Const Cont. Board - - Exp. Date . X
required if Lic.# 106842 . 6/7/99 • Solar Compliance • - .
expired in COT - (Calculation Attached) •
database - Plumbing Lic. # Exp. Date I hearby acknowledge that I have read this application, that the
26 -564PB ' 6/30/98 information given is correct, that I am the owner or authorized
Name agent of the owner, and that plans submitted are in compliance
with Oregon State laws.
Electrical B EAR E LECTRIC, INC. • sig a of er /Ager�'�j
rt 71 pat �
.Sub- Mailing Address I/l (P�, O
Contractor PO Box 389 Contact Person Na e . Phone#
City /State Zip Phone Peter Ku s y k -- 524-1999 2 4 - 19 9 9
Prior to per - FOR OFFICE USE ONLY'
i ssu a noe,acopy Donald ,OR 97020 678 -1 -355 Plat #: yak yet trP_
Map/TL#:
of all licenses are Oregon Const Cont. Board Exp. Date ( t c, • 151 72ybi _ o �
required if Lic.# : 2 0 919 2/20/00 Setbacks: Zone: 5J Solar. •
expired in COT 12 S ALIA ciittAgelfi ill r -t-
database Electrical Lic. # • - Exp. Date
24 -107C Engineering Appr val: Planning Approval: TIF:
. 10/1/98
.
SF
I:REM ,DOC:,(DST)
5/7/99 Activities for Case #: MST98 -00264
11:26:29 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB005 Application received 6/25/98 B RECD BON 6/29/98
MSTB008 Permit created 6/29/98 B DONE BON 6/29/98
MSTB010 Check for prd. restrict. BON 6/29/98
MSTB012 Plans routed to Plans Examiner 6/29/98 B SENT BON 6/29/98
MSTB030 Reviewed plans routed to DSTS 7/28/98 RDP PASS JSD 7/29/98
MSTB032 DST Post Review Completed 7/29/98 JSD PASS JSD 7/29/98
MSTB700 Erosion Control Insp 844 -8444 8/17/98 USA PASS RB 8/19/98
MSTB703 Grading Inspection RDP 7/2/98 Special Inspection Only by
Geo -Tech, See Soils Report
MSTB705 Footing Insp 8/13/98 RB FAIL JT 8/18/98 Regiestered survey required to
establish property lines prior to
footing pour. special inspection
required for rough grading USA
erosion required post address
signage not ready
MSTB706 Foundation Insp 8/25/98 RB PART RB 8/25/98 Seismic restraint placement.
NOT INCLUDING FWD AND
INTERIOR FOOTINGS.
MSTB715 Slab Insp 9/4/98 RB PASS RB 9/4/98 HD's to be installed at later
date.
MSTB720 Plm /undslb Insp 8/31/98 MS PASS MRS 8/31/98
MSTB723 Electrical Service 12/16/98 CD PASS CD 12/17/98
MSTB724 Electrical Rough -in 12/9/98 BRP PASS CD 12/17/98
MSTB725 Mechanical Insp 12/16/98 RB FAIL J *H 12/18/98 See framing.
MSTB727 Low Voltage BON 6/29/98
MSTB729 Plumbing Top Out 12/4/98 MS PASS MRS 12/7/98
MSTB730 Framing Insp 10/14/98 RB PART RB 10/14/98 Garage exterior wing walls- OK
to close up for shear req'mts.
MSTB740 Gas Line Insp 12/16/98 RB PASS J'H 12/18/98 Tag 340409
MSTB741 Gas Fireplace N/A RB 12/28/98
MSTB745 Insulation Insp 12/18/98 RC FAIL J'H 12/20/98 not ready
MSTB750 Shear Wall Insp 10/1/98 RB - FAIL RB 10/1/98 Not ready !
MSTB755 Firewall Insp 9/17/98 RB FAIL RB 9/17/98 See City of Tigard Row Housing
Policy for details of Party Walls
• Not Ready !!!! Interior gypsum -
ok, BUT, rock wool required at
top /bottom plates and at 10'
intervals.
MSTB775 Rain Drain Insp 8/31/98 MS PASS MRS 8/31/98
Page 1 of 5
5/7/99 Activities for Case #: MST98 -00264
11:26:29 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB780 Water Line lnsp 8/31/98 MS PASS MRS 8/31/98
MSTB781 Water Service lnsp BON 6/29/98
MSTB785 Appr /Sdwlk Insp JMT N/A JT 5/7/99 private street
MSTB789 Smoke Detector BON 6/29/98
MSTB790 Fire Alarm lnsp BON 6/29/98
MSTB796 Electrical Final 3/3/99 CD PASS CD 3/4/99
MSTB797 Plumb Final 3/12/99 TLP PASS TLP 3/12/99
MSTB798 Mechanical Final 3/23/99 RB FAIL AKJ 3/23/99 See bldg final notes
MSTB799 Building Final 3/23/99 RB FAIL AKJ 3/23/99 1) Unable to view mechanical in
attic 2) Cover clean outs within
wall cavity 3) Contingent to
planning approval for conditions
of site
MSTB080 (F) Ready to issue 7/29/98 JSD PASS JSD 7/29/98
MSTB050 Hold for - 8/4/98 DEB DONE DRA 8/4/98 Hold pending release from Eng
& Pin. Permit back in Bob T's
area.
MSTB055 Hold Release 8/5/98 DEB DONE KJP 8/5/98
MSTB080 (F) Ready to issue 8/5/98 DEB MEMO DLH 8/12/98 Must pay fee in lieu of
undergrounding prior to
issuance. Check SUB97 -0002.
Fee in -lieu of undergrounding
$6,517.50 for SUB97 -0002 was
paid on 08/12/98. DLH
MSTB092 (F) Issue combination permit 8/12/98 DLH DONE DLH 8/12/98
MSTB095 Issue plumbing signature form 5/7/99 JMT RECD JT 5/7/99
MSTB097 Issue Electric Signature Form 8/18/98 JMT RECD JT 8/18/98
MSTB705 Footing Insp 8/18/98 RB PART RB 8/19/98 BUILDING 1 11380 SW
Thunder 1. Rear exterior footing
only! 2. Submittal of Geo-tech
and Survey reports req'd. 3.
PRIOR TO SLAB, an inspection
shall be req'd for bearing pads
and interior footings. Ufer not
tagged at this time- NO
FOOTING.
MSTB705 Footing Insp 9/4/98 RB PASS RB 9/4/98 Interior footings- HD's to be
installed at later date.
MSTB760 Gyp Board Insp 1/4/99 RB PART RB 1/4/99 1st Layer lid and underneath
stairs.
Page 2 of 5
5/7/99 Activities for Case #: MST98 -00264
11:26:29 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB755 Firewall lnsp 9/17/98 10/1/98 RB PART RB 10/1/98 2nd floor- rock wool at party
walls; inner rim and floor
decking over party wall- ok, as
per plans.
MSTB760 Gyp Board lnsp 9/17/98 1/6/99 RB PASS RB 1/7/99 Missed nailing thru -out
(minimal). Nail where marked.
MSTB755 Firewall lnsp 9/17/98 10/14/98 RB PART RB 10/14/98 3RD FLOOR LEVEL ONLY !
Submit Geo -Tech report, if not
already sent. OK to stand walls
upright, but do not close up w/o
inspection. 1st Level -
Garage /storage walls need to
be inspected prior to erecting.
MSTB760 Gyp Board lnsp 9/17/98 RB 9/17/98
MSTB755 Firewall Insp 9/18/98 RB PART RB 9/18/98 Repair hole in gyp.- Rock wool -
ok
MSTB760 Gyp Board Insp RB 10/14/98
MSTB750 Shear Wall lnsp 10/14/98 RB PART RB 10/14/98 OK to dose up wing walls of
- exterior only.
MSTB750 Shear Wall Insp 10/21/98 RB PART RB 10/21/98 Located HD -5A installed at fwd
location at property line west
wall. Contractor to cover! AS
PER PLANS.
MSTB745 Insulation Insp 10/21/98 RB PART RB 10/21/98 Property line west wall at
basement level- ok
MSTB755 Firewall lnsp 10/21/98 RB PART RB 10/21/98 Property line west wall- ok,
except where missed nailing -
minimal; Nail as per schedule.
MSTB737 Roof Nailing 11/4/98 RC FAIL J *H 11/4/98 Roof not framed as per plans.
Resubmit plans for approval.
MSTA726 Shear Wall lnsp 11/6/98 RB FAIL RB 11/6/98 NOT READY!
MSTB750 Shear Wall Insp 11/10/98 WDJ PART WDJ 11/10/98 1. Install HD5A's at back of
garage. (One is missing, the
other is currently an HD2A) 2.
Install horizontal straps at girder
truss. (Master bath area)
NOTE: Drywall shear will
require inspection. OK TO SIDE
Page 3 of 5
5/7/99 Activities for Case #: MST98 -00264
11:26:29 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB730 Framing Insp 12/11/98 RB FAIL J *H 12/15/98 INSPECTION TERMINATED:
1. Electrical cover. -2. Drywall
rated walls, i.e., under stairs,
chases, soffits. 3 Bearing stud
support needed. 4. Support
notched TJI's. 5. Lid unusable
and fireplace enclosures;
behind showers, etc. 6. Protect
CPVC within fireplace
enclosures. 7. In attic, protect
plumbing lines from freeze: HW
heater. 8. Strap plates where
marked. 9. Strap beam /post
connections. 10. Provide a
walkway (2 -ft. wide) to
mechanical equipment in attic -
unable to view mechanical
equipment in attic - no access.
11. Separation wall termination
above ceiling - please review.
12. No gas test.
MSTB725 Mechanical Insp 12/11/98 RB FAIL J *H 12/15/98 INSPECTION TERMINATED
SEE FRAMING THIS DATE.
MSTB730 Framing Insp 12/16/98 RB FAIL J *H 12/18/98 1. Insulation requirements not
met at time of inspection. 3.
Framing issues incompleted. 4.
Mechanical issues incompleted.
MSTB755 Firewall Insp 12/18/98 RC FAIL J *H 12/20/98 Not ready
MSTB740 Gas Line Insp 12/18/98 RC PASS J'H 12/20/98 no tag number given
MSTB772 Engineered grading final reprt 12/24/98 HAP NOTE J'H 12/24/98 Carlson approved compaction
for pad. Letter to file.
MSTB725 Mechanical lnsp 12/28/98 RB PASS RB 12/28/98
MSTB730 Framing Insp 12/28/98 RB PART RB 12/28/98 Protect hot -water heater in
attic- from insulation.
MSTB745 Insulation Insp 12/28/98 RB PART RB 12/28/98 Chink windows and doors
where lacking in proper seal.
Protect H.W.Heater from
insulation in attic. Protect water
lines in attic. Insulate garage
wall to under stairs. Firestop all
thru hole penetrations; ie.
plates, unusable spaces, etc.
MSTB755 Firewall Insp 12/28/98 RB PART RB 12/28/98 Between units not complete at
this time- ok at gypsum.
MSTB755 Firewall Insp 1/4/99 RB PART RB 1/4/99 1st layer lid in garage
underneath stairs.
MSTB755 Firewall lnsp 1/4/99 1/6/99 RB PASS RB 1/7/99
MSTB760 Gyp Board Insp 1/4/99 RB 1/4/99
Page 4 of 5
5/7/99 Activities for Case #: MST98 -00264
11:26:29 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB706 Foundation Insp 1/19/99 RB RETN RB 1/20/99 RETAINING WALL: Keystone
Type- Submit Special
Inspection Reports.
MSTB798 Mechanical Final 4/1/99 WDJ PASS AKJ 4/1/99
MSTB799 Building Final 4/1/99 WDJ PASS AKJ 4/1/99
MSTB950 (F) Issue Cert. of Occupancy 5/7/99 JMT DONE No Hold JT 5/7/99
•
Page 5 of 5
• 'rITY OF TIGARD BUILDING INSPECTION DIVISION MST q� -O�l4y
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
rrJJ BUP
Date Requested `"L"(� G q q AM PM BLD
Location 1 1 3 � /L Suite � MEC
Contact Person eel( i Ph ,S'7.7�5q r / PLM
Contractor Ph SWR
cffilnaTi Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceili
Roof
Misc:
.1 Pi) . PART FAIL
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
Post & Beam
G s Li n I n
Gas e /
a Lie �✓/
S • ke Dampers
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain • [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA Z
Approach /Sidewalk
Other Date 0/77 Inspector WPWA--- Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD
A Program for Inspection Services and/or Material Testing
Date: • . ,1918
of sr Qt -out ,
City of Tigard: Plan Ck. No.(ka - $r�p NO.oL4 ef Sit No.
Project Title: .ifir-a-n4 file,A'tt15 Address Qu- Co+t C DAko.r► IG oo Bteri4
Architect of Record 4?rE,& A.. Ph. 5 1 -.2421
address: to5?D •w e..xr rto4 'P2 . iNssidativ.a ,q2
Structural Engineer of Record: Ph.
address:
Geo- Technical Engineer of Record: CAt4 cvJ 1 + Ph. &BA - 340
address: Pm bo.o. 236 t - 'TiemAta . OR-
Provide the following information for the toting agency chosen to provide inspection services and/or testing.
Testing Agency: Ph. Fax.
address
Geo-Technical Agency: k.4. 1 44 Ph. (e$ A -3 4,o Fax.
address i% box 238tA - —f1 o�, q ?Ze t
The owner certifies that the above noted Agency has been employed to conduct the
special inspections or observations required herein.
Simature of Owner Phone No. Date
Print name Company name
The following is a list of special inspection and/or services required by the 1996 Oregon
Structural Specialty Code and Tigard's Municipal Code 14.06.010 through 14.06.040.
The special inspections and/or testing services required for this project to be provided by the Testing
Agency, Structural Engineer or Geo - Technical Engineer of Record are as follows:
• Special Inspectors for the Testing Agency shall be qualified, to the satisfaction of
the Building Official. for inspections of the particular type of construction or operation.
• Special inspectors shall observe the work assigned herein for conformance with the
approved plans and specifications and. submit copies of all inspection reports and. a
final signed report in accordance with OSSC. Section 1701.3 to the building official.
Category Description of Services_ Required Provided B-"
Yes / No
1. Footings adjacent to slopes steeper than 33 -1/3 % OSSC, Section 1806.4
a. Confirm building footings are properly set back from descending slope
b.
2. Grading OSSC. Section 3309
a. Regular grading [less than 5,000 cu. yds. but considered unusual] • •
Requirements for engineered grading apply.
b Engineered grading [exceeds 5,000 cu. yds.]
Submit: 1. Geo- technical engineers report and,
2. a engineering geology report.
3. an as -built grading plan and,
4. a final report prepared by the soils engineer and,
5. the final report prepared by the geologist.
C. X
3. Fills OSSC, Section 3313
a. Preparation of ground. for fill on slopes exceeding I to 5 (20 %)
Includes benching and proper termination at the toe of the slope
b Acceptance of fill materials
C. Compaction of fill material to minunum 90% of maximum density.
13125 SW Hall Blvd., Tigard, OR 97223 [503] 639 -4172 FAX [503] 684 -7297