Permit r .
CITY OF TIGARD MASTER PERMIT
(4,- ,,f �, DEVELOiNVIENT SERVICES PERMIT # • MST98 —O2E3
0 h
=:_.. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171
PARCEL: 1S134DA —DMO23
SITE ADDRESS. - .:11370 SW THUNDER TERR
SUBDIVISION - DAKOTA MEADOWS ZONING: R -12 PD
BLOCK LOT -023 JURISDICTION:
Remarks: New SFA - Path 1 - Special Inspection for rough grading - Registered survey required to establish proper y Ines
BUILDING
REISSUE: STORIES • 3 FLOOR AREAS BASEMENT...: 8 sf REQUIRED SETBACKS— REQUIRED
CLASS OF WORKHEIGHT • 34 FIRST : 623 sf GARAGE • 462 sf LEFT : 0 SMOKE DETECTRS: Y
TYPE OF USE...:SFA FLOOR LOAD • 40 SECOND...: 842 sf FRONT • 8 PARKING SPACES: 2
TYPE OF CONST.:5N DWELLING UNITS: 1 FINBSMENT: 842 sf RIGHT : 0
OCCUPANCY GRP.:R3 BDRM: 2 BATH: 3 TOTAL : 2307 sf VALUE..$: 163082 REAR • 0
PLUMBING --
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 1% TRAPS • 0
LAVATORIES : 3 DISHWASHERS...: 1 FLOOR DRAIN..: 0 SEWER LINE ft: 1'.6 SF RAIN DRAINS: 2 CATCH BASINS..: 0
TUB /SHOWERS...: 2 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1'A BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
— -------------- — MECHANICAL - —
FUEL TYPES — FURN ( 100K ..: 0 BOIL /CAP ( 3HP: 1 VENT FANS • 3 CLOTHES DRYERS: 1
GAS FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 0 OTHER UNITS...: 1
MAX INP.: 250000 BTU FLOOR FURNACES: 0 VENTS : 1 WOODSTOVES....: 0 GAS OUTLETS...: 1
— ELECTRICAL
— RESIDENTIAL UNIT— -- SERVICE /FEEDER— —TEMP SRVC /FEEDERS— —BRANCH CIRCUITS — ----MISCELLANEOUS ---- - -ADD'L INSPECTIONS -
1'.' SF OR LESS: 1 0 - 288 amp..: 0 0 - 280 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 508SF.: 4 201 - 400 amp..: 0 201 - 480 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 8
LIMITED ENERGY.: 0 401 - 608 amp..: 0 401 - 608 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 8 IN PLANT • 8
MANF HA /SVC /FDR: 0 601 - 1' amp.: 0 601 +amps -1%% v: 0 MINOR LABEL -10: 0
1m+ amp /volt.: 0 - -- PLAN REVIEW SECTION --
Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR)=225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC:
ELECTRICAL - RESTRICTED ENERGY -
P. SF RESIDENTIAL B. COMMERCIAL
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARA • INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: OTH:X .. BOILER • HVAC • LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: ..
HVAC • DATA /TELE COMM.: NURSE CALLS TOTAL It SYSTEMS: 0
Owner: Contractor: — -- TOTAL FEES:$ 4455.46
BEACON HOMES INC BEACON HOMES This permit is subject to the regulations contained in the
9508 SW 125TH AVE 9580 SW 125TH Tigard Municipal Code, State of Ore. Specialty Codes and all
BEAVERTON OR 97' BEAVERTON OR 97Y other applicable laws. All work will be done in accordance
with approved plans. This permit will expire if work is
Phone M): 524 -1999 Phone 0: 524 -1999 not started within 180 days of issuance, or if the work is
Reg MN..: % suspended for more than 180 days. ATTENTION: Oregon law
- -- -- requires you to follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth in OAR 952-081 -8010 through OAR 952- 081-0888. You may obtain copies of these rules or
direct questions to OUNC by calling (503)246 -1987.
. REQUIRED INSPECTION
Erosion Control Plm /undslb Insp Plumbing Top Out Insulation Insp Water Service In Plumb Final
Grading Inspecti Electrical Servi Framing Insp Shear Wall Insp Appr /Sdwlk Insp Mechanical Final
Footing Insp Electrical Rough Fireplace Insp Firewall Insp Smoke Detector Building Final
Foundation Insp Mechanical Insp bas Line Insp Rain Drain Insp Fire Alarm Insp
Slab Insp : w Vo Gas Fireplace Water Line Insp Electrical Final
Issued By // i00 ii Permittee Signature: : < ..
+ + + + + ++ + + ++ 7.1144-4- . + + + + + + + + + + + + + + + + + + + + + + + + + + ++ • + + + + + ++ + + + + + + + + ++
Call 639 -4175 by :00 p.m. for an inspection needed the next ■usiness day
�' x� - • Plan Check #(6 — y
CITY OF TIGARD - Residential Building Permit Application' Recd By OW
13125 SW HALL BLVD. New Construction Additions or Alterations Date Recd —Z
TIGARD, OR 97223 z Single Family Detached or Attached (Duplex) • - " ' Date to P.E.b —
V 503-639-4171 - - _ 1 Date to DST 1 28 L' $ I.'
F I Permit #' I. —043' t
Pr Type . . - - Called . 7zss g , X
• Incomplete or illegible applications will not be accepted
BUILDING 1 — Lot 23
. Name of Project - Name • , _ •
Job DAKOTA MEADOWS PETER MAGARO
Site A ddress Architect Mailing Address -
. 10570 'SW. Citati Dr" ": •" - `
Address
• .
. ,- - .11370 SW."Thunde•r'Terrace . •
Name City/State Zip _ Phone
Beaverton 97008.. 579 -2421
BEACON HOMES. INC. Name
Owner Mailing Address JEFF DOVE ENGINEERING
9500 SW 125th Avenue En Mailing Address
.City/State Zip Phone g • Inver. 4914 Oakridge' Rd. -
Beaverton 97008 524 -1999 •
General Name - City/State • Zip Phone
4'2,14 Lake Oswego 97035 697 -5926
Contractor BEACON HOMES, INC : • ,4 41G6 Describe work . New Addition 0 Alteration O " Repair 0
Mailing Address to be done: ' '
Prior to permit - 9500 SW 125th" Avenue Additional Description of,Work: •
issuance, a copy City/State Zip - Phone attached single- family dwellings.
of all licenses Beaverton 97008 524 -1999 [
are required if Oregon Const. Cont Board . Exp. Date PROJECT ' • /6 ?j o g . -
expired in COT Lic.# 70782 • _ 1.2/17/98 VALUATION $ ' "
database
Mechanical Name V - NEW ONLY:
Sub- -MUEHE ' QUALITY' HEATING Sq. Ft. House: - Sq. Ft. Garage
Contractor Mailing Address • 18 3 3 800
Prior to permit PO Box 9 _ ' Corner Lot ' YES NO Flag Lot YES NO
issuance, a copy City/State Zip Phone (check one) - - X (check one) X
of all licenses West Linn 97068 598 -0966 Restricted Audio /Stereo Burglar
are required if . Oregon Const. Cont Board Exp. Date
expired in COT Lic.# 50096 _ 3/5/99
Energy System Alarm
database • Installation Garage Door HVAC
Plumbing Name Opener yes Systems X
Sub CUSHMAN FAMILY PLUMBING " (check all that Other - V
Contractor " - Mailing_Address apply) V • •
4535 SE 35th Place. Will the electrical subcontractorwire'forall._ YES . NO
" - restricted energy installations? v "
Promo permit City/State • Zip Phone Has the Subdivision Plat recorded? N /A- YES ' NO
issuance, a copy Portland 97202 775 -4472
of all licenses are Oregon Const Cont Board " " Exp: Date _ X
required if • Lic.# - 106842 • 6/7/99 - Solar Compliance " - •
expired in COT (Calculation Attached) • " • •
database Plumbing Lic. # Exp. Date I hearby acknowledge that I have read this application, that the
2 6- 5 6 4 P B 6/30/98 information given is correct, that 1 am the owner or authorized -
Name - agent of the owner, and that plans submitted are in compliance
with Oregon State laws.
B EAR ELECTRIC, INC. •
Electrical Signat�r� of ner/ • e t n at �,�
Sub Mailing Address V l/ Jtj/ I
Contractor , PO Box 389 -- Contact Person Name YYY "` V one #
• City/State Zip Phone " Peter Ku s y k 524-1999
Prior to perrriit FOR OFFICE USE ONLY:
issuance,acopy
Donald ,OR 9702 678 -1355 PI #: llv1 rarla A s
�.�� Map/TL#:
of all licenses are Oregon Const Cont. Board T .- - Exp. Date M4 —i ' . . , i • ; V S( 34 .V4 - tmo z3
required if Lic 20919 - 2/20/00 Setbacks: Zone: -
. expired in COT - Solar:
database Electrical Lic. # , • Exp. Date �%'.7 � � � � � 1 ` - �� �7 T
r 1/
Engineering Approval: Planning Approval: TIF:
24 -107C 10/1/98
" I:SFREM.DOC < (DST),C4/97
6 /8 /99 Activities for Case #: MST98 -00263
2:33:13 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB005 Application received 6/25/98 B RECD BON 6/29/98
MSTB008 Permit created 6/29/98 B DONE BON 6/29/98
MSTB012 Plans routed to Plans Examiner 6/29/98 B SENT BON 6/29/98
MSTB030 Reviewed plans routed to DSTS 7/28/98 RDP APPR RDP 7/28/98
MSTB032 DST Post Review Completed 7/29/98 JSD PASS JSD 7/29/98
MSTB700 Erosion Control Insp 844 -8444 8/17/98 USA PASS RB 8/19/98
MSTB703 Grading Inspection RDP 7/2/98 Special Inspection Only - See
Soils Report
MSTB705 Footing Insp 8/13/98 RB FAIL JT 8/18/98 Register survey required prior
to pour of footings to establish
property lines special inspection
required for rough grading USA
erosion required post address
signage not ready
MSTB706 Foundation Insp 8/25/98 RB PART RB 8/25/98 SEISMIC RESTRAINT
PLACEMENT. NOT
INCLUDING INTERIOR AND
FWD FOOTINGS
MSTB715 Slab lnsp 9/4/98 RB PASS RB 9/4/98 HD'S to be installed at later
date.
MSTB720 Plm /undslb lnsp 8/31/98 MS PASS MRS 8/31/98
MSTB723 Electrical Service 12/16/98 CD PASS CD 12/17/98
MSTB724 Electrical Rough -in 12/16/98 CD PASS CD 12/17/98
MSTB725 Mechanical Insp 12/28/98 RB PART RB 12/30/98 See framing this date.
MSTB727 Low Voltage BON 6/29/98
MSTB729 Plumbing Top Out 12/10/98 MS PASS MRS 12/11/98 •
MSTB730 Framing Insp 10/13/98 RC FAIL J *H 10/14/98 Not ready.
MSTB735 Fireplace Insp N/A RB 12/28/98
MSTB740 Gas Line lnsp BON 6/29/98
MSTB741 Gas Fireplace N/A RB 12/28/98
MSTB745 Insulation Insp 12/18/98 RC FAIL J *H 12/20/98 not ready
MSTB750 Shear Wall Insp 10/1/98 RB FAIL RB 10/1/98 Not ready !!!!
MSTB755 Firewall Insp RDP 7/28/98 See City of Tigard Row Housing
Policy Guide for 2 hour party
wall construction
MSTB775 Rain Drain lnsp 8/31/98 MS PASS MRS 8/31/98
MSTB780 Water Line Insp 8/31/98 MS PASS MRS 8/31/98
Page 1 of 5
6 /8/99 Activities for Case #: MST98 -00263
2:33:13 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB781 Water Service Insp BON 6/29/98
MSTB785 APPr /Sdwlk Insp 5/9/99 N/A AKJ 5/9/99 Private Drive
MSTB789 Smoke Detector BON 6/29/98
MSTB790 Fire Alarm Insp BON 6/29/98
MSTB796 Electrical Final 3/3/99 CD PASS CD 3/4/99
MSTB797 Plumb Final 3/12/99 TLP PASS TLP 3/12/99
MSTB798 Mechanical Final 3/23/99 RB FAIL AKJ 3/23/99 See bldg final notes
MSTB799 Building Final 3/23/99 RB FAIL AKJ 3/23/99 1) Unable to view attic
mechanical 2) Cover dean -outs
within wall cavity 3) Cap rain
drain riser If. side of garage 4)
Contingent to planning approval
for conditions of site 5) Correct
open corner of roof over entry.
MSTB050 Hold for 8/4/98 DEB HOLD DRA 8/4/98 Hold pending release from Eng
& Pln. Permit back in Bob T's
area.
MSTB055 Hold Release 8/5/98 DEB MEMO KJP 8/5/98
MSTB080 (F) Ready to issue 8/5/98 DEB DONE DLH 8/12/98 Must pay fee in lieu of
undergrounding prior to
issuance. Check SUB97 -0002.
Fee In -Lieu of Undergrounding
$6,517.50 for SUB97 -002 paid
on 08/12/98. DLH
MSTB092 (F) Issue combination permit 8/12/98 GEO PASS GEO 8/12/98
MSTB095 Issue plumbing signature form 8/18/98 JMT RECD JT 8/18/98
MSTB097 Issue Electric Signature Form 8/18/98 JMT RECD JT 8/18/98
MSTB705 Footing Insp 8/18/98 RB PART RB 8/19/98 BUILDING 1 (11390 SW
Thunder) 1. Ufer tagged. 2.
8 -feet in from curb- entire
exterior perimeter, except wings
at front. 3. Submittal of
Geo -tech and Survey reports
req'd. 4. PRIOR TO SLAB, an
inspection shall be req'd for
bearing pads and interior
footings. Ufer ground ok for
this unit, but not tagged for
middle unit <11380> lot 24.
MSTB705 Footing Insp 9/4/98 RB PASS RB 9/4/98 Interior footings ok- HD's to be
installed at later date.
Page 2 of 5
6/8/99 Activities for Case #: MST98 -00263
2:33:13 PM
Assigned Hold Updated
• Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB755 Firewall Insp 10/1/98 RB PART RB 10/1/98 2nd floor- rock wool at party
walls; inner rim and floor
decking over party walls- ok, as
per plans.
MSTB755 Firewall Insp 10/14/98 RB PART RB 10/14/98 3rd level only. Please submit
Geo-Tech soil report, if not
already sent. Garage 1 -hr walls
need to be inspected before
standing upright.
MSTB730 Framing Insp 10/14/98 RB PART RB 10/14/98 3RD FLOOR LEVEL ONLY !
OK TO STAND 1 -HR WALLS
UPRIGHT, BUT DO NOT
CLOSE UP W/O INSPECTION
OF FRAMING 1ST LEVEL -
GARAGE WING WALLS- OK
TO CLOSE UP- EXTERIOR
ONLY.
MSTB750 Shear Wall Insp 10/14/98 RB PART RB 10/14/98 OK TO CLOSE UP WING
WALLS OF GARAGE ONLY.
MSTA726 Shear Wall Insp 10/21/98 RB PART RB 10/21/98 Noted HD 5A in property line
west wall- ok to cover.
MSTB745 Insulation Insp 10/21/98 RB PART RB 10/21/98 0913 am property line west
wall- ok
MSTB750 Shear Wall Insp 10/21/98 RB PART RB 10/21/98 0913 am Noted HD5A in
property line west wall- ok-
Contractor wanted to cover.
MSTB755 Firewall Insp 10/21/98 RB PART RB 10/21/98 0913 am property line west
wall.
MSTB737 Roof Nailing 11/4/98 RC FAIL J *H 11/4/98 Roof not framed as per plans.
Resubmit plans for approval.
MSTA726 Shear Wall Insp 11/6/98 RB FAIL RB 11/6/98 NOT READY! '
MSTB750 Shear Wall Insp 11/10/98 WDJ PART WDJ 11/10/98 1. Install nuts on bolts of
holddown in corner of storage
room. 2. Install missing HD2A
at interior wall between storage
area and garage. 3. Install
horizontal straps at girder truss.
NOTE: Drywall shear will
require inspection. OK TO SIDE
MSTB795 Misc. Inspection 11/12/98 RDP 11/12/98 #1 this inspection is for
Keystpne walls - If over 6 "
special inspection by Carlson is
required. #2 Backfill against the
walls regarless of height shall
be inspected by Carlson and
approved.
MSTB755 Firewall Insp 12/18/98 RC FAIL J *H 12/20/98 not ready
MSTB772 Engineered grading final reprt 12/24/98 HAP NOTE J *H 12/24/98 Carlson approved compaction
for pad. Letter to file.
Page 3 of 5
•
6/8/99 Activities for Case #: MST98 -00263
2:33:13 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB730 Framing Insp 12/28/98 RB PART RB 12/30/98 Cnpple stud missed at main
entry below window. Insulate
water lines to H.W. Heater in
attic. Close off unusable spaces
upstais bthrm- 2- chases.
Provide walk -way to Mech in
attic. Extend exhaust venting to
roof vent. Mechanical in attic
not checked- No Access
(ladder, etc.).
MSTB755 Firewall Insp 12/28/98 RB PART RB 12/28/98 Between units still incompleted-
ok at gypsum.
MSTB730 Framing Insp 12/30/98 RB PART RB 12/30/98 MECHANICAL IN ATTIC NOT
CHECKED- NO ACCESS- third
attempt. View at Final! CHECK
FIREWALL AT GYPSUM
INSPECTION (UNDERNEATH
• STAIRS).
MSTB725 Mechanical Insp 12/30/98 RB PART RB 12/30/98 See Framing this date.
MSTB745 Insulation Insp 12/30/98 RB PART RB 12/30/98 Insulate water line in garage.
Firestop all thru hole
penetrations in garage soffit.
Protect gas line at rear soffit in
garage. Insulate underneath all
shower /tubs; hard -to -reach
areas, ie. underneath platforms,
dryer venting, fwd bedrm
ceiling, attic walkway, thru top
plates and above soffit in
kitchen. OK TO DRYWALL -
FIRST LAYER OF GARAGE
LID AND UNDERNEATH
STAIRS AT FIRST LEVEL
ENTRY.
MSTB760 Gyp Board Insp 12/30/98 NOTE RB 12/30/98 Check firewall underneath stairs
& first lid of garage.
MSTB760 Gyp Board Insp 12/30/98 1/4/99 RB PART RB 1/4/99 1st lid for garage and
underneath stairs.
MSTB755 Firewall Insp 1/4/99 RB PART RB 1/4/99 1st layer lid for garage and
underneath stairs.
MSTB755 Firewall Insp • 1/4/99 1/6/99 RB PASS RB 1/7/99
MSTB760 Gyp Board Insp 1/4/99 1/6/99 RB $ 30 RB 1/7/99 Inspection dtd. 12 -28 -98 RB-
req'd stud under window at
main entry... failed to
accomplish correction. $30.00
re- inspect fee assessed. All
issues with drywall /firewall
completed.
Page 4 of 5
6 /8/99 Activities for Case #: MST98 -00263
2:33:13 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB760 Gyp Board Insp 1/7/99 1/6/99 RB PASS RB 1/7/99 2nd inspection this date.
Waived re- inspection fee
$30.00 from prior inspection.
MSTB730 Framing Insp 1/7/99 RB 1/7/99
MSTB791 «REINSPECTION» 1/7/99 1/6/99 RB WAIV RB 1/7/99 $30.00 re- inspection fee
assessed for non - compliance of
correction from 12 -28 -98 RB
inspection, RE: missed stud
under window at main entry.
2nd inspection this date- waived
re- inspection fee, stud installed
as was directed.
MSTB706 Foundation Insp 1/19/99 RB RETN RB 1/20/99 RETAINING WALL: Keystone
Type- Submit Special
Inspection Reports.
MSTB798 Mechanical Final 4/1/99 WDJ PASS AKJ 4/1/99 extend duct to roof jack in attic
space
MSTB799 Building Final 4/1/99 WDJ PASS AKJ 4/1/99
MSTA960 (F) Issue Cert. of Occupancy 4/1/99 TIG WJ DONE No Hold JT 5/28/99 mailed 5/28/99
•
•
•
Page5of5
CITY OF TIGARD BUILDING INSPECTION DIVISION
MST qe - 024o3
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUD
Date Requested AM PM BLD
Location / (3 7 3 Suite MEC
Contact Person OA) 1 f) Ph 5Z2 -'2S-/ PLM
Contractor Ph SWR
V1ILbl • Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain
SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear 11 � ■
Framing x I't d t) I OLP
Insulation \..1
Drywall Nailing a 14 k Seems
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
ASS PART FAIL
P MBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
1 eam / Rough In
Gas Line
Smoke Dampers
F'
AS PART FAIL •
nRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART . FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk y77
Other Date // / c� Inspector Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
•
CITY OF TIGARD
A Program for Inspection Services and/or Material Testing
Date: #7 1 1 ,19 1S
qk -o 2 - 43 ,
City of Tigard: Plan Ck. No.41 $epNo.oLL¢02GS Sit No.
Project Title: •arq ltleAtet45 Address A. Co.s DA"'" lt3oo &cti )
Architect of Record PerEl& 14146.04040 Ph. Sig -2421
address: 0510 °C.,trarto4 'D2 . F tea poz
Structural Engineer of Record: Ph.
address:
Geo- Technical Engineer of Record: CAtt. rriat,.3 Ph. (084 - 3kb
address: Po blew. 2$e - 'T . OR.
Provide the following information for the testing agency chosen to provide inspection services and/or testing.
Testing Agency: Ph. Fax.
address
Geo- Technical Agency: Net_ v 1 Ph. CB A 134.0 Fax.
address Qcbcuz Ptt - — fl 4eb,OR 11 ?Let •
The owner certifies that the above noted Agency has been employed to conduct the
special inspections or observations required herein.
Signature of Owner Phone No Date
Print name Company name
The following is a list of special inspection and/or services required by the 1996 Oregon
Structural Specialty Code and Tigard's Municipal Code 14.06.010 through 14.06.040.
The special inspections and/or testing services required for this project to be provided by the Testing
Agency, Structural Engineer or Geo- Technical Engineer of Record are as follows:
• Special Inspectors for the Testing Agency shall be qualified, to the satisfaction of
the Building Official, for inspections of the particular type of construction or operation.
• Special inspectors shall observe the work assigned herein for conformance with the
approved plans and specifications and. submit copies of all inspection reports and. a
final signed report in accordance with OSSC. Section 1701.3 to the building official.
i•
Category - Description of Services_ Required Provided By
Yes / No
1. Footings adjacent to slopes steeper than 33 -1/3 % OSSC, Section 1806.4
a. Confirm building footings are properly set back from descending slope
b.
2. Grading OSSC. Section 3309
a. Regular grading [less than 5,000 cu. yds. but considered unusual] • •
Requirements for engineered grading apply.
b Engineered grading [exceeds 5,000 cu. yds.]
Submit: 1. Geo- technical engineers report and,
2. a engineering geology report.
3. an as -built grading plan and,
4. a final report prepared by the soils engineer and,
5. the final report prepared by the geologist.
C. _ -X
3. Fills OSSC, Section 3313
a. Preparation of ground. for fill on slopes exceeding 1 to 5 (20 %)
Includes benching and proper termination at the toe of the slope
b Acceptance of fill materials
C. Compaction of [ill material to minimum 90% of maximum density.
13125 SW Hall Blvd., Tigard, OR 97223 [503] 639-4172 FAX [503] 684 -7297
I:'BLDGSPL1 NISP1.DOC