Loading...
Permit MASTER PERMIT CITY TIGARD PERMIT #: MST1999 -00198 :4411161 DEVELOPMENT SERVICES DATE ISSUED: 6/7/99 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 ..„, Ni.. SITE ADDRESS: 10140 SW TIGARD ST � PARCEL: 1S135CC -03600 SUBDIVISION: GREENBURG HEIGHTS ADDITION ' t ZONING: R -4.5 BLOCK: LOT: 010 JURISDICTION: TIG REMARKS: Converting a detached garage attic space into livable space. Will need county approval before connecting bathroom to septic tank BUILDING REISSUE: STORIES: FLOOR AREAS REQUIRED SETBACKS REQUIRED CLASS OF WORK: ALT HEIGHT: FIRST: sf BASEMENT: sf LEFT: SMOKE DETECTORS: Y TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 630 sf GARAGE: sf FRONT: PARKING SPACES : TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: sf RIGHT. VALUE: $ 20,000 00 OCCUPANCY GRP: R3 BDRM: 1 BATH: 1 TOTAL: sf REAR: PLUMBING SINKS: WATER CLOSETS: 1 WASHING MACH: LAUNDRY TRAYS: RAIN DRAIN: TRAPS: LAVATORIES: 1 DISHWASHERS: FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: CATCH BASINS: TUB /SHOWERS: 1 GARBAGE DISP: WATER HEATERS: 1 WATER LINES: BCKFLW PREVNTR: GREASE TRAPS: OTHER FIXTURES: MECHANICAL FUEL TYPES FURN < 100K: BOIL/CMP < 3HP: VENT FANS: 1 CLOTHES DRYER: ELE FURN > =100K: UNIT HEATERS: 3 HOODS: OTHER UNITS: MAX INP: btu FLOOR FURNANCES: VENTS: W0ODSTOVES: GAS OUTLETS: ELECTRICAL RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS 1000 SF OR LESS: 1 0 - 200 amp: 0 - 200 amp: W /SVC OR FDR: PUMP /IRRIGATION: PER INSPECTION: EA ADD'L 500SF: 201 - 400 amp: 201 - 400 amp: 1st W/O SVC /FDR: SIGN /OUT LIN LT: PER HOUR: LIMITED ENERGY: 401 - 600 amp: 401 - 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT: MANU HM /SVC /FDR: 601 - 1000 amp: 601 +amps- 1000v: MINOR LABEL: 1000+ amp /volt : PLAN REVIEW SECTION Reconnect only: >=4 RES UNITS: SVC /FDR> =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC: ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM:' INTERCOM/PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVE SIGNL: GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR: HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS: Owner: Contractor: TOTAL FEES: $ 530.86 WEBB, This permit is subject to the regulations contained in the WS, ROBERT LEE WALTER W MACKA BEN EB TIGARD B Tigard Municipal Code, State of OR Specialty Codes and EDNA M 102 WALTER R SW TIGARD TIGARD, TI TI GARD all other applicable laws. All work will be done in 10140 accordance with approved plans. This permit will expire if TIGARD, OR 97223 work is not started within 180 days of issuance, or if the work is suspended for more than 180 days. ATTENTION: Phone: Phone: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set Reg #: LIC 00033576 forth in OAR 952 - 001 -0010 through 952 - 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503) 246 -1987 REQUIRED INSPECTIONS Sewer + s3spestiea - Electrical Service Electrical Final Underfloor insulation Electrical Rough In Mechanical Final PLM /Underfloor Framing lnsp Plumb Final Mechanical Insp Insulation Insp Final inspection PIum4- Top —... Water Line lnsp Building Final ,i Iss d By :' • f . < 0 ' Permittee Signature : ,m....„42 , _ . N. `•may; Call (503) 639 -4175 by 7:00 p.m. for an inspection needed the nex busine - da CITY OF TIGARD Residential Building Permit Application Plan Check �'�'� 13125 SW HALL BLVD. Alteration - Interior Remodel Only Rec'd By Date Rec'd l — l TIGARD, OR 97223 Single Family Detached or Attached (Duplex) Date to P.E. --- Iq -9 9 V 503 - 639 -4171 Date to DST S - - 2 v - / F 503 - 684 -7297 Permit # ( I — On Print or Type Called 1 j — ZI —G I9 Incomplete or illegible applications will not be accepted Name of Project Name Job /p0/1L.0 -- 5- W-1 8- Architect Mailing Address Address s itddfess 2r` ^ �'� N l City /State Zip Phone • C 1 .__> e>i'v W'el(0 Name Owner Mailing dre r Engineer Mailing Address City /State Zip Phone g Name - City /State Zip Phone General ,}� Contractor Vie% %',e / Describe work New 0 Addition 0 Alteration Repair 0 'Mailing Address to be done: L • Prior to permit ijj , !"? ,,,� Addition 1 escn iisn, of Work: - - ` ff4!` p - issuance, a copy 'City/State Zip ° Phone ```.. ''' - e- . -'• �-/ - • % '∎ • of all licenses r egon �1t '�^,, % 0,,rr�•� - - are required if Const. Cont. Board ' Exp. Date • PROJECT expired in COT Lic.# 33 57b q-2.1)-1 G►� VALUATION $ /,JQ„7 • e 767 database _ Mechanical Name NEW CONSTRUCTION ONLY: Sub- VV / /I/ NCLI406d Sq. Ft. House: Sq. Ft. Garage • Contractor Mailing Address 1 Prior to permit n?pb I �q 6.4d\ ST • Indicate the restricted energy installation by the electrical issuance, a copy J C,dy /State Z' Phone subcontractor in the following areas of all licenses (l/ (� tiy)- 2.41 -14I Restricted Audio /Stereo are required if Ore, � on Corist. Cont. Board Exp. Date Energy System Alarms • expired in COT Lic. 2 `�7 � j - Installations Vacuum Irrigation 2 j database J (0 q ' l / System System Plumbing Name / � ' (check all that Other: rettf, Sub- l� Ly ir1i & apply) C r Mailing Address Corner Lot YES • NO Flag Lot YES NO OntraCtO h . - (check one) (check one) !' + Has the Subdivision Plat recorded? N/A YES NO Prior to permit City /State Zip Phone issuance, a copy 7 Solar Compliance of all licenses are Oregon Const. Cont. Board Exp. Date (Calculation Attached) required if (Lic.# / hearby that I have read this a expired in CO U 12 q (ail A- I h D acknowledge h i _ application, that the database Plumbing Lic. � e Exp. Date information given is correct, that I am the owner or authorized agent 3g _ 53l rb ( , -30 -7 ? of the owner, and that plans submitted are in compliance with Oregon State laws. Name ce R 1 Si • nat re of O , ner /Agent , / Date Electrical } a n EAtec tC- i,_.., w . .�/ /iii %:.:�:����j -� - o ontact • er a c Phone # Sub- Mailing Address tI ^ 1 A o n v 1 2 , 1 Contractor FOR OFFICE CE USE ONLY: I V �7 I City/State Zip Phone Plat #: Map/TL #: I ) . --- � — �a� Prior to permit n LO 4-F U Q - 9 7097 /J t3 issuance, a copy of all licenses are Oregon Const. Cont. Board Exp. Date Se Zone: (�2 S Solar: ^ I n required if 11Lic.# ! A-- Q ) ) ti expired in CO a 1,0 II /Z7 ( D 0 Engineering Approval: Planning A / alp TIF: t p database Electrical Lic. # /8 -I �9 Exp. Da e -, /`-' A .fp I' eW I�1C 1V tr7 o ff ► -2-1 - Z- a /ZC io /l / 10 52 o-il ) %cd cow ti» 13414 � eo�.� --/41 .�3 I S II GTG71/( /a - / -°/ I:SFREM2.DOC (DST) 8/11/98 1/25/00 Activities for Case #: MST1999 -00198 3:33:17 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA005 Application received 5/18/99 BON RECD No Hold BON 5/19/99 MSTA008 Permit Created 5/19/99 BON DONE No Hold BON 5/19/99 MSTA010 Check for prcl. restrict. 5/19/99 BON DONE No Hold BON 5/19/99 Mark Roberts approved 5/18/99. . MSTA012 Plans routed to Plans Examiner 5/19/99 BON DONE No Hold BON 5/19/99 MSTA026 Plans approved by Pln Examiner 5/20/99 BT2 DONE No Hold BT2 5/20/99 MSTA030 Reviewed plans routed to DSTS 5/20/99 BT2 DONE No Hold BT2 5/20/99 MSTA704 Sewer Inspection No Hold BT2 5/20/99 sewer will run into a septic tank will need county approval MSTA712 Underfloor insulation 5/20/99 5/20/99 No Hold BT2 5/20/99 MSTA717 PLM /Underfloor 5/20/99 5/20/99 8/3/99 MS PASS No Hold AKJ 8/3/99 MSTA720 Mechanical lnsp 5/20/99 5/20/99 8/31/99 RB PASS No Hold AKJ 9/1/99 MSTA722 Plumb Top Out 5/20/99 5/20/99 8/3/99 MS PASS No Hold AKJ 8/3/99 MSTA723 Electrical Service 5/20/99 5/20/99 8/9/99 BRP PASS No Hold AKJ 8/9/99 MSTA724 Electrical Rough In 5/20/99 5/20/99 8/9/99 BRP PASS No Hold AKJ 8/9/99 MSTA725 Framing lnsp 5/20/99 5/20/99 7/14/99 RB FAIL No Hold AKJ 7/14/99 1) elec cover req prior to framinc 2) plm not installed yet, no mech installed yet 3) framing issues- lower bedroom window to 44" 4) temp glazing req for window adj to door w /in 24" 5) energy window req at bdrm or storm window req 6) rafters req to have 1" air space for insul re. path 8 vaulted ceiling insp term MSTA740 Insulation lnsp 5/20/99 5/20/99 NOTE No Hold RDP 8/26/99 An alternate has been approved on the insulation values. This is an existing attic space converted into habitable space.. Under the provisions of E101.2.3, footnote 3 of table E401.1b can be used. The existing 2X6 rafter will take R -21, the attic space next to the R -21 pony walls will have R -38 in addition to that called out on the plans. Any ?s call Bob P MSTA760 Water Line Insp 5/20/99 5/20/99 No Hold BT2 5/20/99 Page 1 of 2 1/25/00 Activities for Case #: MST1999 -00198 3:33:17 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA790 Electrical Final 5/20/99 5/20/99 10/29/99 BP FAIL No Hold VT 10/29/99 Receptaacles must cmply with article 370 -20, 380 -10, 410 -56 Firmly mount receptacles to face of wall or box. MSTA795 Mechanical Final 5/20/99 5/20/99 10/13/99 RB PASS No Hold ST 10/14/99 1. Seal gas line through shield 2. Protect gas line at exterior - . paint w /metal type paint MSTA797 Plumb Final 5/20/99 5/20/99 1/19/00 TLP PASS No Hold_ AKJ 1/19/00 MSTA798 Final inspection 5/20/99 5/20/99 No Hold BT2 5/20/99 MSTA799 Building Final 5/20/99 5/20/99 1/19/00 TLP PASS No Hold AKJ 1/19/00 MSTA032 DST Post - Review Completed 5/21/99 BON DONE No Hold BON 5/21/99 MSTA080 (F) Ready to issue 5/21/99 BON DONE No Hold BON 5/21/99 Must submit letter of authorization from Washington County approving new bathroom for existing septic tank. MSTA092 (F) Issue combination permit 6/7/99 DEB DONE No Hold DST 6/7/99 MSTA705 Footing lnsp 6/15/99 6/15/99 6/15/99 LN PASS No Hold AKJ 6/15/99 MSTA725 Framing Insp 8/26/99 8/26/99 8/26/99 LN PASS No Hold AKJ 8/26/99 ok to insulate pending ok from city for R21 at existing ceiling MSTA725 Framing Insp 9/1/99 9/1/99 8/31/99 RB PASS No Hold AKJ 9/1/99 MSTA740 Insulation lnsp 9/1/99 9/1/99 8/31/99 RB PART No Hold AKJ 9/1/99 1) insulate If side of upstairs window 2) ins window and door jambs when installed and /or provide an ext vapor barrier and place 12 -21 valve insul as a temp solution until windows and doors are installed 3) insul soffit in gar where plm installed 6) protect ext plm through wall /sheathing at rear do not drywall until #2 completed MSTA790 Electrical Final 12/15/99 12/15/99 12/10/99 BP PASS No Hold DGW 12/15/99 MSTA970 Case Finaled 1/19/00 AKJ DONE No Hold AKJ 1/19/00 • Page 2 of 2 CITY OF TIGARD BUILDING INSPECTION DIVISION MST / c 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 / u /1 /9)11 BUP Date Requested '' /? ( AM / PM BLD Location / D f1 "10 I 5( l Bard S1 • Suite MEC Contact Person L!)a Ph &3? ? " 9 PLM Contractor Ph ti ' SWR BUILDING Tenant/Owner . ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear - Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS FAIL l (ELECTR1 V Service Rough In UG /Slab Low Voltage - Alarm al PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: ] Unable to inspect - no access ADA i Approach /Sidewalk / G Other Date I — / LO 7 Inspector .� /_ _ AA � ■ Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the site. CITY OF TIGARD BUILDING INSPECTION DIVISION sT j qq9 -col q g 24 -Hour Inspection Line: 639 -4175 . Business Line: 639 -4171 4:4_716b1 BUP Date Requested I r X / AM PM Bf_D Location 101 90 Ti A Suite (cri 9' ctpq Z .•• Contact Person bula k*- Ph (Q N q PLM Contractor Ph SWR c UILDIN) Tenant/Owner ELC Retaining Wall ELR Footing Access: i 1 e Foundation V \ ,` }c FPS Ftg Drain �� -��� SGN Crawl Crawl Drain Inspection Notes: Slab � � � -e.r f SIT Post & Beam Ext Sheath /Shear Ina Insulation She /Shear (I _ y ,. (� (� r ," " \ Framing l./(Jy�,, f7n1 Z_� - �rf�( -Ai N" \ � U D S • Drywall Nailing 7J� 7 Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: PART FAIL i " Blip Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains —. PART FAIL F Post & Beam Rough In 7' 0�1 1 Gas Line 1� 4. -/ Smoke Damp :J; ^= PART FAIL ELECTRICAL Service Rough In UG /Slab ✓ Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA l Approach /Sidewalk Other D ■ -l�d0 Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.