Permit . CITY OF TIGARD MASTER PERMIT
A. Av , A DEVELOPMENT SERVICES PERMIT # - MST98 -0270
'i' 1 DATE ISSUED: 08/20/98
v+� ' � �.- 13125 SW Hall Blvd., Tigard, OR 97223 (503) 6394171
PARCEL: 1S134DA —DMO22
SITE ADDRESS...: 11350 SW THUNDER TERR
SUBDIVISION •DAKOTA MEADOWS ZONING: R -12 PD
BLOCK LOT -022 JURISDICTION: ?
Remarks: New SPA - Path 1 - Special Inspections for rough grading - Registered survey required to establish property lines
BUILDING —
REISSUE: `\ STORIES • 3 FLOOR AREAS -- BASEMENT...: 0 sf REQUIRED SETBACKS— REQUIRED- -
CLASS OF WORK. :NEW`' HEIGHT : 26 FIRST 71 sf GARAGE • 380 sf LEFT : 0 SMOKE DETECTRS: Y
TYPE OF USE...:SFA FLOOR LOAD • 40 SECOND...: 714 sf FRONT • 8 PARKINS SPACES: 2
TYPE OF CONST.:5N DWELLING UNITS: 1 FINBSMENT: 714 sf RIGHT • 0
OCCUPANCY 6RP.:R3 BDRM: 2 BATH: 3 TOTAL : 1499 sf VALUE—$: 154300 REAR • 0
— PLUMBING — —
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 100 TRAPS • 0
LAVATORIES • 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 1.'' SF RAIN DRAINS: 2 CATCH BASINS..: 0
TUB/SHOWERS...: 2 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1% BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
MECHANICAL - -- - --
FUEL TYPES FURN l 100K ..: 0 BOIL /CMP ( 3HP: 1 VENT FANS • 3 CLOTHES DRYERS: 1
GAS FURN )= 1' ..: 1 UNIT HEATERS..: 0 HOODS • 0 OTHER UNITS...: 1
MAX INP.: 250080 BTU FLOOR FURNACES: 0 VENTS • 1 WOODSTOVES • 0 GAS OUTLETS...: 1
- ------ — ELECTRICAL - - - - -- ------
- -RESIDENTIAL UNIT— — SERVICE /FEEDER— —TEMP SRVC /FEEDERS— — BRANCH CIRCUITS — -- MISCELLANEOUS— - -ADD'L INSPECTIONS-
1'I'. SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 580SF.: 2 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGTN /OUT LIN LT: 0 PER HOUR • 0
LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0
MANF HM /SVC /FDR: 0 601 - 1cw amp.: 0 601 +amps- 1wir v: 0 MINOR LABEL -10: 0
1' amp /volt.: 0 --------- ------------ PLAN REVIEW SECTION - - - - - -- -
Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC BCC:
- -- ELECTRICAL - RESTRICTED ENERGY - - ___ - --
A. SF RESIDENTIAL B. COMMERCIAL— — --
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: OTH:X .. BOILER • HVAC • LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: ..
HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL B SYSTEMS: 0
Owner: -----------------------------------Contractor: --------------- TOTAL FEES:$ 4362.17
BEACON HOMES INC BEACON HOMES This permit is subject to the regulations contained in the
9500 SW 125TH AVE 9500 SW 125TH Tigard Municipal Code, State of Ore. Specialty Codes and all
BEAVERTON OR 97':.8 BEAVERTON OR 97'.' other applicable laws. All work will be done in accordance
with approved plans. This permit will expire if work is
Phone B: Phone B: 524 -1999 not started within 180 days of issuance, or if the work is
Reg D..: m707 suspended for more than 180 days. ATTENTION: Oregon law
- - -- — ----- — requires you to follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth in OAR 952-081 -0010 through OAR '41 -0080. You r y obtain copies of these rules or
direct questions to OUNC by calling (503)246 -1987. -
- REQUIRED INSPECTIONS • `�'�"'`'
Erosion Control Plu /undslb Insp Plumbing Top Out Shear Wall Insp App /Sdwlk Insp Building Final
Grading Inspecti Electrical Servi Framing Insp Firewall Insp S . e Detector
Footing Insp Electrical Rough 6as Line Insp Rain Drain Insp Electrical Final
Foundation Insp Mechanical Insp Gas Fireplace Water Line Insp Plumb Final
Slab Insp Low Volt Insulation Insp Water Service In Mechanical Final
Issued By: Permittee Signature:
++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++
Call 639 -4175 by 7:00 p.m. for an inspection needed the next business day
CITY OF TIGARD Residential Building Permit Application Recd By
13125 SW HALL BLVD. New Construction Additions or Alterations Date Recd / - �5 -
TIGARD, OR 97223 Single Family Detached or Attached (Duplex) Date to P.E. - A
V 503 -639 -4171 Date to DST 1 L 6 Q
F 503 -684 -7297 ✓I i Permit #M - 07 -1D' rah -
Print or Type /( Called 01 ‘t
Incomplete or illegible applications will not be acc ted - -
BUILDING 2 - Lot 22
Name of Project Name -- .
Job DAKOTA MEADOWS PETER'MAGARO ARCHITECTURE
Architect Mailing Address
Site Address
Address 10570 SW Citation Dr.. •
11350 SW. Thunder Terrace City /State Zip Phone
Name _ Beaverton 97008 - 579 -2421
BEACON HOMES, INC. Name "
Owner Mailing Address JEFF DOVE ENGINEERING
9500 SW 125th Avenue
Engineer En Mailing Address
City /State Zip Phone g 4914 Oakr Rd.
Beaverton 97008 524 -1999
General Name City/State Zip Phone
Lake Oswego 97035 697 -5926
Contractor BEACON HOMES , INC : • Describe work New b Addition 0 Alteration 0 Repair 0
Mailing Address to be done:
Prior to permit 9500 SW 125th Avenue Additional Description of Work:
issuance,acopy City/State Zip Phone attached single- family dwellings.
ofallilcenses Beaverton 97008 524 -1999
are required if Oregon Const. Cons Board Exp. Date PROJECT
expired in COT Lic.# 70782 12/17/98 •VALUATION $ 154,300.00
database
Mechanical Name NEW CONSTRUCTION ONLY:
Sub - MUEHE • QUALITY HEATING Sq. Ft. House: Sq. Ft. Garage
Contractor Mailing Address 1 700 800
Prior to permit PO Box 9 _ Corner Lot YES NO Flag Lot YES NO
issuance, a copy City /State Zip Phone (check one) X (check one) X
of all licenses West Linn 97068 5 9 8 - 0 9 6 6 Restricted Audio /Stereo Burglar
are required if Oregon Const. Cons Board Exp. Date
expired in COT Lic.# 50096 � 3/5/99 Energy System Alarm
database litstallation Garage Door HVAC
Plumbing Name Opener yes _ Systems X
Sub- CUSHMAN FAMILY PLUMBING (check all that Other.
Contractor . Mailing Address appl
V
4535 SE 35th Place ' Will the electrical subcontractor wire forall YES NO
. • V restricted energy installations?
Prior to permit City/State Zip Phone - Has the Subdivision Plat recorded? N/A YES NO
issuance, a copy Portland 97202 775 -4472
of all licenses are Oregon Const Cont. Board Exp. Date X
required if Lic.# 106 842 6/7 Solar Compliance
expired in COT (Calculation Attached)
database Plumbing Lic. # Exp. Date I hearby acknowledge that I have read this application, that the
2 6- 5 6 4 P B 6/30/98 information given is correct, that I am the owner or authorized
Name agent of the owner, and that plans submitted are in compliance
• Or- . on State laws.
B EAR ELECTRIC, INC.
Electrical Si : - of Own - r /A•egt "/
Sub- Mailing Address / , I �( �7 rf)e-51c-6
Contractor PO Box 389 C. tact Person Nam: ��' """((( "`��� Phone#
City/State Zip Phone Peter Kusyk 524 -1999
Prior to pemlit Donald, OR 97020 678 -1355 FOR OFFICE USE ONl.Y;
issuance, a copy P�la # huf'et" tre Map/TL#:
of all licenses are Oregon Const Cont Board Exp. Date � s I4( 341Y
required if Lic
expired in COT 20919 2/20/00 Setbacks ` '' Zo : Solar.
database Electrical Lic. # Exp. Date � � `F�' S U V
Engineering App }oval: Planning Approval: '11F: 24 = 107C 10/1/98
•
- I:SFREM.DOC (DST) 4/97
6/7/99 Activities for Case #: MST98 -00270
2:47:47 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB005 Application received 6/25/98 B RECD BON 6/29/98
MSTB008 Permit created 6/29/98 B DONE BON 6/29/98
MSTB012 Plans routed to Plans Examiner 6/29/98 B SENT BON 6/29/98
MSTB030 Reviewed plans routed to DSTS 7/28/98 RDP APPR RDP 7/28/98
MSTB032 DST Post Review Completed 8/4/98 DEB DONE DRA 8/4/98 Parcel check was to be done by
Planning as this is a multi -unit
attached housing project.
MSTB400 Development Rev Conditions met BON 6/29/98
. MSTB700 Erosion Control Insp 844 -8444 BON 6/29/98
MSTB703 Grading Inspection RDP 7/28/98 Special Inspction Rough
Grading
MSTB705 Footing lnsp RB 8/24/98 Do not approved unless
registered survey is on site and
pins placed
MSTB706 Foundation Insp 9/10/98 RB PART RB 9/10/98 EXTERIOR PERIMETER ONLY
Install HD's at all req'd
locations.
MSTB715 Slab Insp 10/8/98 RC PASS ROC 10/9/98
MSTB720 Plm /undslb Insp 9/24/98 GS PASS J'H 9/25/98
MSTB723 Electrical Service 2/1/99 BRP PASS CD 2/2/99
MSTB724 Electrical Rough -in 1/19/99 CD PART CD 1/20/99 outdoor soffits only
MSTB725 Mechanical lnsp 2/5/99 RB PART RB 2/5/99 See Framing this date. View
attic installation at final.
MSTB727 Low Voltage BON 6/29/98
MSTB729 Plumbing Top Out 1/19/99 MS PASS MRS 1/20/99
MSTB730 Framing Insp 10/13/98 RC FAIL J'H 10/14/98 not ready, permit no.
MSTB740 Gas Line Insp 2/9/99 RB PASS RB 2/9/99 340425
MSTB741 Gas Fireplace N/A RB 2/5/99
MSTB745 Insulation Insp OK RB 2/11/99
MSTB750 Shear Wall Insp 10/2/98 RB PART RB 10/5/98 GARAGE WINGS- OK to cover.
Provide nut/washers for anchor
bolts where missed. MINIMAL.
MSTB755 Firewall lnsp 10/29/98 RC PASS J'H 11/2/98 1ST FLOOR
MSTB775 Rain Drain lnsp 9/24/98 GS PASS J *H 9/24/98
MSTB780 Water Line Insp OK RB 2/11/99
MSTB781 Water Service Insp 9/24/98 GS PASS J`H 9/25/98
MSTB785 APPr /Sdwlk Insp PRIV RB 2/11/99 private drive.
Page 1 of 4
6/7/99 Activities for Case #: MST98 -00270
2:47:47 PM
•
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB789 Smoke Detector N/A RB 2/11/99
MSTB796 Electrical Final 4/8/99 BRP PASS AKJ 4/11/99 Garage switch on wrong side of
door, patching walls incomplete
Final pass
MSTB797 Plumb Final 4/13/99 TLP PASS AKJ 4/13/99
MSTB798 Mechanical Final NOTE RB 2/5/99 View attic installation of furnace
and hot -water heater at final- no
access this date.
MSTB799 Building Final 5/5/99 RC PASS AKJ 5/5/99
MSTB080 (F) Ready to issue 8/4/98 DEB DONE DRA 8/4/98
MSTB050 Hold for 8/4/98 DEB HOLD DRA 8/4/98 Hold pending release from Eng
& Pln. Permit back in Bob Ts
area.
MSTB055 Hold Release 8/5/98 DEB DONE DRA 8/5/98
MSTB080 (F) Ready to issue 8/5/98 DEB MEMO DRA 8/5/98 Must pay fee in lieu of
undergrounding prior to
issuance. Check SUB97 -0002.
MSTB705 Footing Insp 8/21/98 RB PART RB 8/24/98 Building 2 Lot 22 Geo-tech and
engineering survey reports to
be submitted. USA approved
this date. Exterior footing only!
Adjacent lot 21 req'd interior
footing, bearing pads, etc. Ufer
tagged.
MSTB700 Erosion Control Insp 844 -8444 8/21/98 USA PASS RB 8/24/98
MSTB095 Issue plumbing signature form 9/1/98 JMT RECD JT 9/1/98
MSTB097 Issue Electric Signature Form 9/1/98 JMT RECD JT 9/1/98
MSTB704 Sewer Inspection 9/24/98 GS PASS J'H 9/25/98
MSTB750 Shear Wall Insp 11/5/98 RB FAIL RB 11/10/98 At interior separation wall -
5/8 -inch - 10 -inch anchors
missed @ 6 -foot ctrs. Complete
securing nuts to HD's where
missed. Tighten all anchor bolts
where missed.
MSTB755 Firewall Insp 11/13/98 11/13/98 RB PART RB 11/13/98 WARNING- Call in address for
right street. Main floor only!
Maintain rock -wool
req'mts /firestopping 10 -foot
intervals.
Page 2 of 4
6/7/99 Activities for Case #: MST98 -00270
2:47:47 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB755 Firewall Insp 11/13/98 12/1/98 RB PART RB 2/5/99 Maintain rockwool firestopping
requirements at 10- intervals.
Protect drywall from weathering
elements (raining at present
time). Repair /protect damaged
drywall where noted. At exterior
walls, provide 1 -hr. protection at
joint(s) connections between
butt ends.
MSTB755 Firewall Insp 11/13/98 2/5/99 RB FAIL RB 2/5/99 Nail Firewall in attic at gable
• end and provide 1 -hr rated wall
at other end. Firecaulk 4 -foot
protection area at roof where
vent penetrates; should not be
within this area- Cast iron vent.
Firewall protection req'd w /in
mechanical chase, refrig. line
chase. View mechanical in attic
at final.
MSTB737 Roof Nailing 12/18/98 RC PASS J'H 12/20/98
MSTB772 Engineered grading final reprt 12/24/98 HAP NOTE J'H 12/24/98 Carlson approved compaction
for pads. Letter of 081998 to
file.
MSTB750 Shear Wall Insp 12/29/98 WDJ PART WDJ 12/29/98 Exterior straps and nailing only.
MSTA724 Electrical Rough In 2/1/99 BRP PASS CD 2/2/99
MSTA728 Low Voltage 2/1/99 BRP PASS CD 2/2/99
MSTB730 Framing Insp 2/9/99 RB FAIL RB 2/9/99 Firestop att thru hole
penetrations. Bearing missed at
garage ext. wall at 6X. Sole
plate blocking missed at firewall
in upstairs bathrooms.
Pre - insulation - ceiling
underneath mech platform in
attic. Attic mechanical to be
viewed at final- No access this
date. Firewall protection req'd in
attic- joint connections. Garage
TJI notched- provide fix. Protect
gyp from black mold.
MSTB725 Mechanical Insp 2/9/99 RB PART RB 2/9/99 See framing this date.
MSTB755 Firewall Insp 2/9/99 RB FAIL RB 2/9/99 See framing this date.
MSTB725 Mechanical Insp 2/11/99 RB PART RB 2/11/99 See at Final- Attic installation.
MSTB745 Insulation Insp 2/11/99 RB PART RB 2/12/99 OK for 1st layer of gypsum
cover. Attic and garage cover.
MSTB730 Framing Insp 2/11/99 RB PART RB 2/11/99 Structural fix- TJI in garage.
Mechanical attic installation.
Page 3 of 4
6/7/99 Activities for Case #: MST98 -00270
2:47:47 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTB755 Firewall Insp 2/11/99 RB PART RB 2/11/99
MSTB725 Mechanical Insp 2/11/99 RB PART RB 2/11/99 View at final- attic installation.
MSTB755 Firewall Insp 2/11/99 RB PART RB 2/11/99 Double layer truss w /in attic at
firewall- rear bedrm closet.
MSTB730 Framing Insp 2/11/99 RB PART RB 2/11/99 Mechanical installation w /in
attic. Firewall application wfin
attic.
MSTB755 Firewall Insp 2/12/99 2/12/99 RB PART RB 2/12/99 Nail gypsum where missed. 1st
layer
MSTB755 Firewall Insp 2/12/99 RB 2/12/99
MSTB760 Gyp Board Insp 2/12/99 2/12/99 RB PART RB 2/12/99 1st layer garage ceiling /under
stairs.
MSTB760 Gyp Board Insp 2/12/99 2/16/99 WDJ PASS WDJ 2/16/99 First layer completed and
approved throughout.
MSTB730 Framing Insp 2/12/99 2/12/99 RB PASS RB 2/12/99
MSTB745 Insulation Insp 2/12/99 2/12/99 RB PASS RB 2/12/99
MSTB798 Mechanical Final 5/5/99 5/5/99 5/5/99 RC PASS No Hold AKJ 5/5/99
MSTB960 Case Finaled 5/5/99 AKJ DONE No Hold AKJ 5/5/99
MSTA960 (F) Issue Cert. of Occupancy 5/5/99 TIG RC DONE No Hold JT 5/28/99 mailed 5/28/99
Page 4 of 4
CITY OF TIGARD BUILDING INSPECTION DIVISION MST Cg - 0270
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested 5-5- [ q q AM PM BLD
Location / /'S0 t.cf \zL. ��• Suite MEC
Contact Person EW I ` ✓J Ph 52 7 - g St O PLM
Contractor Ph SWR
Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath/Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Mi
A S PART FAIL
P L NG
Post & Beam
L Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS P RT FAIL
PostiBeam
Rough In
Gas Line
Smoke Dampers
P S S PART FAIL
EL TRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk S = L 5 �� ery7 C
Other Date Inspector Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.