Loading...
Permit CITY TIGARD MECHANICAL PERMIT I& DEVELOPMENT SERVICES PERMIT #: MEC2001 -00104 r � J I I 1 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 4/3/01 PARCEL: 2S112CA -06600 SITE ADDRESS: 15230 SW THURSTON LN SUBDIVISION: ASHFORD OAKS ZONING: R -7 BLOCK: LOT: 020 JURISDICTION: TIG CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: SF UNIT HEATERS: VENT FANS: OCCUPANCY GRP: SR3.3 VENTS WIO APPL: VENT SYSTEMS: STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: DOMES. INCIN: 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: FIRE DAMPERS ?: 30 - 50 HP: REPAIR UNITS: GAS PRESSURE: 50 + HP: WOODSTOVES: FURN < 100K BTU: 1 AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: < =10000 cfm: OTHER UNITS: > 10000 cfm: GAS OUTLETS: Remarks: Furnace replacement in garage. Owner: FEES THOMSON, ROBERT A + EVELYN L T Type By Date Amount Receipt PO BOX 231225 PRMT CTR 4/3/01 $72.50 2720010000 TIGARD, OR 97281 5PCT CTR 4/3/01 $5.80 2720010000 Total $78.30 Phone: Contractor: BELL HEATING (GREG MILLETT) 15550 SE PIAZZA AVE REQUIRED INSPECTIONS CLACKAMAS, OR 97015 Heating Unt Insp Phone: 656 -1184 Final Inspection Reg #: LIC 447 PLM 3 -286PB This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 -001 -0010 through OAR 952 - 001 -0080. You may obtain copies o these rules or direct questions to OUNC by calling (503)246 -9189. Issue By: ( :, �. t ✓��,,� Permittee Signature: '<cfl/\ � Q Call (503) 639 -4175 by 7:00 P.M. for inspections needed the next business day c\k k t` . , Mechanical Permit Application RECEI Date received:)_ Q/ Permit no.:MLL- / -OO /0' City of Tigard Project/appl.no.: Expire date: City of Tigard Address: 13125 SW Hall Blvd, Tigard, OR, 9 2 , Date issued: By: Receiptno.: Phone: (503) 639 -4171 /'{ F' 2 200 i Fax: (503) 598 -1960 Case file no.: Payment type: COMMUNITY DEVELOi 'Mtt , 'Building permit no.: Land use approval: TYPE OF PERMIT '% : 2 family dwelling or accessory ❑ Commercial/industrial ❑ Multi- family ❑ Tenant improvement 0 New construction ❑ Addition/alteration/replacement 0 Other: JOB SITE INFORMATION COMMERCIAL VALUATION SCHEDULE Job address: 1 5 6 S AA./ " A.A- S-}-010. Indicate equipment quantities in boxes below. Indicate the dollar Bldg. no.: I Suite no.: value of all mechanical materials, equipment, labor, overhead, Tax map /tax lot/account no.: profit. Value $ . Lot: IBlock: I Subdivision: *See checklist for important application information and Project name: jurisdiction's fee schedule for residential permit fee. City /county: I ZIP: - 1` - 8 2 FA IILI' rtraYt P 7ilV�I C E E Description and location of work on premises: Fur s a.« AND COMMERICALJINDUSTRIAL EQUIPMENTSCHEDULE f ! ........ - _ Fee(ea.) Total Est. date of completion/inspection: 4 Description Qty. Res. only Res. only Tenant improvement or change of use: HVAC: Is existing space heated or conditioned ?Yes ❑ No Air handling unit CFM Air conditioning (site plan required) Is existing space insulatedPaYes ❑ No Alteration of existing HVAC system MECHANICAL CONTRACTOR Boiler /compressors State boiler permit no.: Business name: - mammalian= HP Tons BTU /H Address: S _ ' — r�� Fire /smoke dampers/duct smoke detectors City: k-., (� WWI ZIP: *'26 — Heat pump (site plan required) Phone: ,. - //� Email: Install/replace furnace/burner /_S BTU /H �. Including ductwork/vent liner 0 Yes ❑ No , 1 ° CCB no.: L#1 7 Install/replace/relocate heaters — suspended, City /metro lic. no.: wall, or floor mounted Name (please print): Vent for appliance other than furnace CONTACT PERSON Refrigeration: Absorption units BTU /H Name:1Z(1 \3Q Y -i- ' I Chillers HP Address: k5 .3O S . Uti V\ u r—S-±0 )1 Compressors HP Environmental exhaust and ventilation: City:` cL &c. State: a Q I ZIP: 9 7, sz e/ Appliance vent Phone: 6P8 t s—) Fax: E -mail: Dryer exhaust OWNER Hoods, Type I/ IUres. kitchen/hazmat hood fire suppression system Name: 2 C) I j ' ( .i- t ,r5 < p .\-- Exhaust fan with single duct (bath fans) Mailing address: ' S- Exhaust system apart from heating or AC Fuel piping and distribution (up to 4 outlets) City: I State: I ZIP: Type: LPG NG Oil Phone: Fax: E -mail: Fuel piping each additional over 4 outlets ENGINEER Process piping (schematic required) Name: Number of outlets Other listed appliance or equipment: Address: Decorative fireplace City: I State: I ZIP: Insert — type Phone: I Fax: I E -mail: Woodstove/pelletstove �� ��, Other: Applicant's signature���� y b_ Date: " 3 /' Other: Name (print): Permit fee $ —V Not all jurisdictions accept credit cards, please call jurisdiction for more information. Notice: This permit application 0 Visa ❑MasterCard Mi n i mum fee $ � 7,2 expires if a permit is not obtained Credit card number: ' / / ex p p Plan review (at %) $ �---- Expires within 180 days after it has been State surcharge (8 %) $ 5 i S 0 / Name of cardholder as shown on credit card accepted as complete. . $ �-7 TOTAL $ / p ,. 1U v Cardholder signature Amount 440-4617 (6/00/COM) MECHANICAL PERMIT FEES • y COMMERCIAL FEE SCHEDULE: 1 & 2 FAMILY DWELLING FEE SCHEDULE: TOTAL VALUATION: FEE: Description: Price Total Table 1A Mechanical Code Qty (Ea) Amt $1.00 to $5,000.00 Minimum fee $72.50 1) Furnace to 100,000 BTU $5,001.00 to $10,000.00 $72.50 for the first $5,000.00 and including ducts & vents 14.00 $1.52 for each additional $100.00 or 2) Furnace 100,000 BTU+ fraction thereof, to and including $10,000.00. including ducts & vents 17.40 $10,001.00 to $25,000.00 $148.50 for the first $10,000.00 and 3) Floor Furnace $1.54 for each additional $100.00 or including vent 14.00 fraction thereof, to and including 4) Suspended heater, wall heater $25,000.00. or floor mounted heater 14.00 $25,001.00 to $50,000.00 $379.50 for the first $25,000.00 and 5) Vent not included in appliance permit $1.45 for each additional $100.00 or 6.80 fraction thereof, to and including 6) Repair units $50,000.00. 12.15 $50,001.00 and up $742.00 for the first $50,000.00 and Check all that apply: Boiler Heat Air $1.20 for each additional $100.00 or For items 7 -11, see or Pump Cond fraction thereof. footnotes below. Comp ** 7) <3HP;absorb unit 1 to 100K BTU 14.00 ASSUMED VALUATIONS PER APPLIANCE: 8) 3 -15 HP; absorb Value Total unit 100k to 500k BTU 25.60 Description: Qty (Ea) Amount 9) 15 -30 HP; absorb Furnace to 100,000 BTU, including 955 unit .5 -1 mil BTU 35.00 ducts & vents 10) 30 -50 HP: absorb Furnace > 100,000 BTU including 1,170 unit 1 -1.75 mil BTU 52.20 ducts & vents 11) >50HP: absorb Floor furnace including vent 955 unit >1.75 mil BTU 87.20 Suspended heater, wall heater or 955 12) Air handling unit to 10,000 CFM floor mounted heater 10.00 Vent not included in applicance 445 13) Air handling unit 10,000 CFM+ permit 17.20 Repair units 805 14) Non - portable evaporate cooler < 3 hp; absorb. unit, 955 10.00 to 100k BTU 15) Vent fan connected to a single duct 3 -15 hp; absorb. unit, 1,700 6.80 101k to 500k BTU 16) Ventilation system not included in 15-30 hp; absorb. unit, 501k to 1 2,310 appliance permit 10.00 mil. BTU 17) Hood served by mechanical exhaust 30 -50 hp; absorb. unit, 3,400 10.00 1 -1.75 mil. BTU 18) Domestic incinerators >50 hp; absorb. unit, 5,725 17.40 >1.75 mil. BTU 19) Commercial or industrial type incinerator Air handling unit to 10,000 cfm 656 69.95 Air handling unit >10,000 cfm 1,170 20) Other units, including wood stoves Non - portable evaporate cooler 656 10.00 Vent fan connected to a single duct 446 21) Gas piping one to four outlets Vent system not included in 656 5.40 appliance permit 22) than 4 -por outlet (each) Hood served by mechanical exhaust 656 Moro Moro 1.00 Domestic incinerator 1.170 Minimum Permit Fee $72.50 SUBTOTAL: $ Commercial or industrial incinerator 4,590 Other unit, including wood stoves, 656 8% State Surcharge $ inserts, etc. Gas piping 1-4 outlets 360 25% Plan Review Fee (of subtotal) $ Each additional outlet 63 Required for ALL commercial permits only TOTAL COMMERCIAL $ TOTAL RESIDENTIAL PERMIT FEE: $ VALUATION: Other inspections and Fees: 1. Inspections outside of normal business hours (minimum charge -two hours) $72.50 per hour. 2. Inspections for which no fee is specifically indicated (minimum charge -half hour) $72.50 per hour 3. Additional plan review required by changes, additions or revisions to plans (minimum charge -one -half hour) $72.50 per hour * State Contractor Boiler Certification required for units >200k BTU. ** Residential NC requires site plan showing placement of unit. is \dsts \forms\mech- fees.doc 10/11/00 CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 MST BUP Date Requested 171— AM PM BLD Location / )� ) 0, $w 1 u Suite • MEC 2'/_O i( Contact Person Ph '/ 7) PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall - ELR Footing Access: Foundation FPS Ftg Drain Crawl Drain Inspection Notes: SGN Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final - PASS PART FAIL • PLUMBING • . Post & Beam S` Under Slab Top Out Water Service �� • Sanitary Sewer Rain Drains Final PASS PART FAIL J Post & Beam Rough In T"uv // p+ - Gas Line Smoke Dampers PAS PART FAIL ' ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART . FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. ay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ .] Unable to inspect - no access ADA Approach /Sidewalk Other. Date Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection r cord from the job site.