Loading...
Specifications ?8 =ea7/ FACTORY AUDIT MANUAL 9,35 sc✓ ,4/ ETL TESTING LABORATORIES, INC. a S «CE 1896 INDUSTRIAL PARK CORTLAND, NEW YORK 13045 Page 1 of 30 Issued: July 23, 1997 FACTORY AUDIT MANUAL AND PROCEDURAL GUIDE FOR COMPLYING WITH ETL CLASSIFICATION, IN -PLANT LABELING, AND FOLLOW -UP SERVICE REQUIREMENTS ISSUED BY: INTERTEK TESTING SERVICES 1089 EAST COLLINS BOULEVARD RICHARDSON, TX 75081 Ph. 972 - 238 -5591 Fax 972 - 238 -1860 This manual has been prepared for the use of the Participant and Manufacturer identified below in conjunction with the manufacture, testing, and application of the ETL mark to the products specified in the index. IMPORTANT NOTE: In the event that the Inchcape Testing Services representative identifies nonconformance to any provision of this Manual, the Participant shall take one or more of the following actions: 1. Correct the nonconformance; 2. Remove the ETL Classification Mark from nonconforming product; or 3. Contact the issuing product safety evaluation center for instructions. Spray Application Using Flammable and Combustible Materials (NFPA 33, 1995 Edition) Participant: GARMAT USA, INC. 1401 W. Stanford Ave. Englewood, CO 80110 Contact: Mr. John Jurasic Alternate: Mr. Bruce Williams Phone: (303) 781 -6802 x206 - Fax: (303) 761 -8039 Manufacturer: Same as Participant Prepared by: Reviewed byi U Kenneth Hansen :filbert az Ad Project Engineer General M- ager An Independent organization testing for safety, performance, and certification. All services undertaken subject to the following general policy: Reports are submitted for exclusive use of the clients to whom they are addressed. Their significance is subject to the adequacy and representative character of the samples. and to the comprehensiveness of the tests, examinations or surveys made. No quotations from reports or use of ETL's name Is permitted except as expressly authorized by ETL In writing. r 1 ETL Testing Laboratories, Inc. Garmat USA, Inc. Issued: 7/23/97 INDEX Reference Issue Order Total Product Number Date Number Pages General Information N/A 7/23/97 N/A 1 r Index N/A 7/23/97 N/A 1 Correlation N/A 7/23/97 N/A 3 Procedural Guide N/A 7/23/97 N/A 2 Closed top Open Front Paint Spray, 97 *11704 -1 7/23/97 97 *11704 23 Booth Model Numbers 10405, 10420, 10450, 10461, 10465, 10480, 10505, 10520, 10550, 10561, 10565 and 10580. • ETL Testing Laboratories, Inc. Garmat USA, Inc. Issued: 7/23/97 CORRELATION PAGE MULTIPLE LISTING The following products which are identical to those identified in the index except for model number and participant name are authorized to bear the ETL label " under provisions of the ETL Multiple Listing Program. MULTIPLE LISTEE ROTUNDA EQUIPMENT Room 207 D Fairlane Business Park Bldg. III 1555 Fairlane Drive Allen Park, MI 48101 BASIC LISTEE GARMAT USA, INC. 1401 W. Stanford Ave. Englewood, CO 80110 MANUFACTURER Same as Basic Listee. MULTIPLE LISTEE BASIC LISTEE BASIC LISTEE BASIC LISTEE MODEL NO. MODEL NO. REPORT NO. ORDER NO. 10405 10405 10420 10420 10450 10450 10461 10461 10465 10465 10480 10480 10505 10505 10520 10520 10550 10550 10561 10561 10565 10565 10580 10580 1 ETL Testing Laboratories, Inc. Garmat USA, Inc. Issued: 7/23/97 CORRELATION PAGE MULTIPLE LISTING The following products which are identical to those identified in the index except for model number and participant name are authorized to bear the ETL label under provisions of the ETL Multiple Listing Program. MULTIPLE LISTEE Aire Pro Industries, Inc. S.A. 1401 W.Stanford Ave. Englewood, CO 80110 BASIC LISTEE GARMAT USA, INC. 1401 W. Stanford Ave. Englewood, CO 80110 MANUFACTURER Same as Basic Listee. MULTIPLE LISTEE BASIC LISTEE BASIC LISTEE BASIC LISTEE MODEL NO. MODEL NO. REPORT NO. ORDER NO. 10405 10405 10420 10420 10450 10450 10461 10461 10465 10465 10480 10480 10505 10505 10520 10520 10550 10550 10561 10561 10565 10565 10580 10580 ETL Testing Laboratories, Inc. Garmat USA, Inc. Issued: 7/23/97 CORRELATION PAGE MULTIPLE LISTING The following products which are identical to those identified in the index except for model number and participant name are authorized to bear the ETL label under provisions of the ETL Multiple Listing Program. MULTIPLE LISTEE Inter -Mech LDC 1401 W. Stanford Ave. Englewood, CO 80110 BASIC LISTEE GARMAT USA, INC. 1401 W. Stanford Ave. Englewood, CO 80110 MANUFACTURER Same as Basic Listee. MULTIPLE LISTEE BASIC LISTEE BASIC LISTEE BASIC LISTEE MODEL NO. MODEL NO. REPORT NO. ORDER NO. 10405 10405 10420 10420 10450 10450 10461 10461 10465 10465 10480 10480 10505 10505 10520 10520 10550 10550 10561 10561 10565 10565 10580 10580 ETL Testing Laboratories, Inc. Garmat USA, Inc. Issued: 7/23/97 GENERAL: The Participant and Manufacturer have agreed to produce, test, and label ETL Classified products in accordance with the requirements of this procedural guide. The manufacturer has also agreed to notify ETL and to request authorization prior to using alternate parts, components, or materials. COMPONENTS: • Components used shall be those listed in the ETL reports covering the products specified in the index including any amendments and /or revisions. CLASSIFICATION MARK: The ETL Classification mark applied to the products shall either be separable in form, such as labels purchased from ETL, or on a product nameplate or other media only as specifically authorized by ETL. Use of the Classification mark is subject to the control of ETL. MANUFACTURING AND PRODUCTION TESTS: Manufacturing and Production Tests shall be performed as required in this procedural guide. FOLLOW -UP SERVICE: Periodic unannounced audits of the manufacturing facility shall be scheduled by ETL. An audit report shall be issued after each visit. Special attention will be given to the following: 1. Conformance of the manufactured product to the description in this manual. 2. Conformance of the use of the ETL label with the requirements of this procedural guide and the Classification, Labeling, and Follow -up Service Agreement. 3. In -plant quality control procedures and personnel. 4. Manufacturing changes. 5. Performance of specified Manufacturing and Production Tests. ETL Testing Laboratories, Inc. Garmat USA, Inc. Issued: 7/23/97 MANUFACTURING AND PRODUCTION TESTS The participant agrees to conduct the following Manufacturing and Production Tests as specified. GROUNDING CONTINUITY TEST: Method Each product listed below shall be subjected to a test to determine that there is continuity between accessible dead metal parts of the product and the grounding pin of the attachment plug, or the ground lead of the pigtail. If all accessible dead metal is connected together, only a single test need be performed. A visual or audible device (ohmmeter, buzzer, etc.) may be used to indicate grounding continuity. PRODUCTS REOUIRING GROUNDING CONTINUITY TEST: All products listed in the Index. . ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 Page 1 Issued: 7/23/97 CONSTRUCTION PRODUCT COVERED: Closed Top Open Front Paint Spray Booth Models: 10405, 10420, 10450, 10461, 10465, 10480, 10505, 10520, 10550, 10561, 10565, and 10580. PRODUCT SIMILARITY: The models differ: model air direction no. of bays air make up bay access 10405 semi -down flow one none drive in, back out 10420 semi -down flow one heated drive in, back out 10450 down flow one non - heated drive in, back out 10461 down flow one heated drive in, back out 10465 down flow one non - heated drive through 10480 down flow one heated drive through 10505 semi -down flow two none drive in, back out 10520 semi -down flow two heated drive in, back out 10550 down flow two non - heated drive in, back out 10561 down flow two heated drive in, back out 10565 down flow two non - heated drive through 10580 -down flow two heated drive through PRODUCT DESCRIPTION: The product covered by this report is a closed top, open -front paint spray booth that has a ventilation system interlocked to the spray application equipment. The paint spray booth is intended to be used with a Listed, natural gas or propane heating /air handling unit, or a Listed air handling unit without heat. The product is provided with a Listed Industrial Control Panel, and Listed light fixtures for use in Class I or (Class II), Division 2, hazardous locations. The paint spray booth is fully automated and is equipped with an energy saving recycle setting that shuts down the spray equipment during this the recycle mode of operation. The booth is permanently connected to the supply source. The air make up heater (when used) pre- conditions the air to a maximum of 120 °F and is connected through permanently installed ducts. ELECTRICAL RATING: The units are rated: Motor Circuit: 208/230/460 VAC, 69.3/63/31.5 FLA, maximum 46.2/42/21 FLA largest motor, 50/60 Hz, 3 Ph. Lighting circuit: 120/277 VAC, 40/20 Amp, 60 Hz, 1 Ph. GENERAL: Construction Details - For specific construction details, reference should be r made to the following photographs and descriptions. All dimensions are approximate unless otherwise specified. In addition to the specific construction details described in the photographs, the following general requirements also apply. 1. Spacings - The following spacings are maintained through air and over surfaces of insulating material between current carrying parts of opposite polarity, and between current carrying parts and dead metal parts. Maximum Potential Minimum Spacings, inches Involved, volts Through Air Over Surface To Enclosure 51 - 150 1/8 1/4 1/4 151 - 300 1/4 3/8 1/2 301 - 600 3/8 1/2 1/2 ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 Page 2 Issued: 7/23/97 2. Mechanical Assembly - Components such as switches, fuseholders, connectors, wiring terminals, and display lamps are reliably mounted and prevented from shifting or rotating by lockwashers, starwashers, use of multiple screws or bolts. 3. Corrosion Protection - All ferrous metal parts are suitably protected against corrosion by painting, plating or the equivalent. 4. Internal Wiring - Internal wiring to the light fixtures in the paint mixing room is per the NEC, junction boxes are provided for connection to the electrical panel in the field. All wiring is Listed or Component AWM, style 1316, minimum 16 AWG, rated 600 volts, 90 °C. Wiring within the room or within 3 feet of the doors is sealed and complies with the requirements of Class I, Division 2 locations. 5. Grounding - All exposed dead metal parts and all dead metal parts within the enclosure that are exposed to contact during any servicing operation and that are likely to become energized are reliably connected to the grounding terminal in the field wiring box. 6. Accessibility of Live Parts - All uninsulated live parts in primary circuitry, or moving parts, are housed within metal enclosures and are adequately protected. 7. Overload Protection - All motors are protected by overload protective devices located in the electrical panel in the field. All lighting is protected by overcurrent protective devices located in the electrical panel in the field. 8. Installation and Operating Instructions - Instructions for the proper installation and use of this product are provided by the manufacturer. These instructions specify the proper locations where the authorized air make up unite can be installed in order to maintain sufficient air flow through the spray booth; or instructions to provide adequate air supply into building when units are supplied without air make up. The following items are included in the installation and operation instructions: a) Installation checklist - refer to page I1. b) Reference to NFPA 70, NFPA 33 and NFPA 101. c) Instructions for installation of fire extinguishing systems. d) Instructions for the proper placement of electrical components including spacing of a minimum of 5 feet from open face and 3 feet from any hazardous locations. e) Installation provided with Listed light fixtures for use in hazardous locations to be accessed for the inside. f) Location for installation, maintenance labels and unit nameplate. g) Requirements for the location of the paint spray booth with respect to non -fire rated walls and ordinary location electrical components. h) Instructions for separation from other occupancies: 3 foot distance or 1 hour fire wall. i) Routing of exhaust ducts. j) Instructions for source of supply air. k) Operations and maintenance responsibilities of the user. 1) Training requirements of user for all personnel involved in the spray application process. ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 Page 3 Issued: 7/23/97 9. Wiring Diagram - The following are provided. Air Make Up Type No. of bays Refer to page Heated 2 I2 Non Heated 2 I3 None 2 I4 Heated 1 15 Non Heated 1 I6 None 1 I7 10. Nameplate - Constructed of metal or Component Label System, located on the front door of the mixing room, includes: a) Manufacturer's name, Tradename, or Trademark. b) Model no. of paint booth. c) Model no. of control panel. d) Model no. of air make up. e) Model no. of light fixtures. f) Date or period of manufacturing. 11. Warning Labels - Provided as follows: Page Label Location on Booth I8 A Front Header Panel B Side Header Panels C Rear or Side Wall Near Filer Access I9 A Exhaust Box B Exhaust Box I10 A Rear or Side Wall Near Filter Access B Air Make Up Unit Ill A Electrical Control Panel B Electrical Control Panel C Electrical Control Panel 12. Spray Booth Room Configuration — Refer to page I12 for a typical closed top, open -face or open -front paint spray booth layout, and location of lighting, air make up and ventilation fans. 13. Classified Location Diagrams - Refer to pages I13 and I14 for typical closed top, open -face or open -front paint spray booth layout, and location of Class I (or Class II), Division 2 locations. 14. Interlocks - An air actuated electric switch de- energizes the spray air solenoid: 1) the booth is placed in the recirculation mode, 2) If the blowers of the air handling unit are disengaged, 3) If airflow through the exhaust duct is not proven by the airflow proving switch such as in the case of a blower failure. 15. Operation - The following operation features are incorporated into the design when operated with the authorized air makeup systems: a) Spray Mode - When the unit is placed in spray mode both the intake and exhaust motors are functioning and the dampers are positioned so that 100 percent of the intake air is drawn from outside the building and exhausted to the outside of the building and the gas fired heater (if provided) is disengaged. When the booth is placed in this mode the spray air solenoid is energized. b) Recirculation Mode - When the unit is placed in recirculation mode the exhaust blower disengages the dampers are positioned so that 100 percent of the ventilation air is recirculated through the unit. When the booth is placed in this model the spray air solenoid is disengaged. • •ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 . Page 4 Issued: 7/23/97 • .c) Winter Mode - When the unit is placed in Winter mode, operation is identical to spray mode except the gas fired heater (if provided) is engaged and 10 minutes after spray equipment is dormant the unit goes into recirculation mode. • • • • • • • • ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 Page 5 I:'� d: 7/23/97 PHOTO NO. 1 f , — — /fit 7 11111 4 • IIIIIrili e.,. 1 iliiiiiiiiiiiiiiii111111N V' 0 l I r , kV 1 '1?,: ,, . . ' k \ /\11111■.- •,•1! A' Fr/ „ tri 011 / : : :: : ;:.: '1 / '.;',, :ii Q I L i r : �� - I� , „yr. ihr 0/ VAlm..m...,m.... m ® e' ,..111NMIIMININIIINIMIMICI■\ /40 \` • ,, 6 1 1 _ 0----0- 1 __ _ .. . .• . , .. _ _ . ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 Page 6 Issued: 7/23/97 CLOSED TOP, OPEN FRONT PAINT SPRAY BOOTH PHOTO NO. 1 General - Photo No. 1 shows a model 10565 closed top paint spray booth, which represents all other models. 1. Paint Spray Booth Lighting Fixture Assembly - (maximum of eight provided on single bay models and sixteen provided on twin bay models) Listed, Garmat USA, Model no. INT200, 120/277 V, 2.92/1.28 A, 60 Hz. 2. Air Handling /Heating Unit - (models 10420,10461,10480,10520,10561 and 10580 only) Listed, Garmat USA, natural gas model 99270, rated 559,000 maximum BTU input, or propane model 99270P, rated 559,000 max. BTU input. Alternate - Listed, Garmat USA, Model 99273, rated 660,000 max. BTU input, or propane model 99273P, rated 660,000 max BTU input. Alternate - Listed, Garmat USA, Model 99275, rated 1,000,000 max. BTU input, or propane model 99275P, rated 1,000,000 max. BTU input. Alternate - (not shown, building roof top or interior suspension mounted) Listed, Weather -Rite, natural gas model TOT118, rated 1,000,000 BTU. Used in conjunction with Garmat exhaust blower assembly that contains the following components Alternate - (not shown, building roof top or interior suspension mounted) Listed, Weather -Rite, natural gas model TOT218, rated 2,000,000 BTU. Non - heated air make up - (not shown, models 10550,10565 only) Listed, Garmat USA, Non - heated model 99270N. Alternate - (not shown, models 10450, 10465 only) Component, Dayton, 7F832, rated 10290 CFM free air. 3. Internal & Floor Filter - (not shown, all models) Classified, Superior Glass Fibers, Class 2, 2.0 inches thick, Catalog no. 40 -1/2 BTO Glass. Preliminary Filter - (not shown, semi -down flow models only) Component, Garmat USA, THA Fortex, air dispersion filter bank. Materials conform to PPP -B -320 in accordance with ASTM -D -5118. With Fire Retardant Coating. 4. Ceiling Plenum Filter - (3 provided per bay on semi -down flow models and 4 provided per bay on down flow models, not shown) Classified, Class 1, Filtrair, Catalog No. CC -600G; rated 212 °F continuous, 250° F peak. Dimensions 38 -1/2 inches by 106 -1/4 inches by 1 inch thick. Alternate - (3 provided per bay on semi -down flow models and 4 provided per bay on down flow models, not shown) Classified, Class 1, Filtrair, r Catalog No. FF -560G; rated 212 °F continuous, 250° F peak. Dimensions 38- 1/2 inches by 106 -1/4 inches by 1 inch thick. Alternate - (3 provided per bay on semi -down flow models and 4 provided per bay on down flow models, not shown) Classified, Class 1, Viledon, Catalog No. PA /560 G -10; rated 212 °F continuous, 250° F peak. Dimensions 38 -1/2 inches by 106 -1/4 inches by 1 inch thick. ETL Testing Laboratories, Inc. Reference: '97 *11704 -1 Page 7 Issued: 7/23/97 5. Floor Grating - (down flow models only) Steel, Individual dimensions 2 inches by 39 -1 /4inches by 31 inches (16 -1/4 inches center row); over all each bay 78.57 inches wide by 196.85 inches long. 6. Wall Section - (double layer) Powder coated steel, 0.035 inch thick, 2 inch hollow center. Alternate - (single layer) Powder coated steel, 0.0478 inch thick. 7. Exhaust Fan Blower Assembly - Consists of the following components: Exhaust Fan - (not shown) Intervent - Nicotra, Catalog No. RDZ 500, anti - spark aluminum inlet rings, reverse incline, rated 19,000 CFM ® 2,400 RPM. Blower Motor - Component, Baldor, Cat No. M3714T, rated 208/230/460 VAC, 28/26/13 10 Hp, 50/60, 3 Ph, class F, 40 °C ambient, 1745 RPM. 8. Ceiling Plenum Filter Holders - (not shown) Aluminum, 0.050 inch thick, held to filter beam by bolts. 9. Exhaust Duct /Access Panel - (not shown) Duct: Sheet steel, 0.035 inch thick; minimum 25 inches by 25 inches cross section, maximum 30 feet long, provided with a maximum of (2) 45 degree bends. Panel: Minimum 12 inches by 12 inches, located a minimum of every 15 feet. 10. Intake Duct - (not shown) Sheet steel, 0.035 inch thick, minimum 20 inches by 30 inches cross section, maximum 30 feet long. Provided with maximum (2) 90 degree bends with turning vanes. 11. Fire System - (not shown) System is to be used with one of the following types of systems: a) Automatic water sprinklers. b) Dry chemical systems. c) Halon 1211 or 1301 type systems 12. Compressed Air Solenoid - (not shown) Component, Parker Fluidpower, Catalog No. 08F23C2140ACF; rated 120 volts, 20 VA, 60 Hz. 13. Cabin - (model 10405, 10420, 10450, 10461, 10465 and 10480) Internally 19 feet, 11 inches long, 11 -1/2 feet wide, 9 feet high. Cabin - (model 10505, 10520, 10550, 10561, 10565 and 10580) Internally 19 feet, 11 inches long, 23 feet wide, 9 feet high. law ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 Page 8 Issued: 7/23/97 PHOTO NO. 2 • "ill r • 0 l � w . ID ��� 1- --- •-•-•-" r..........-...............-... Mid::::' _ ".a.. ' IY o. iw ._. • . .4_ w O a. W 9 > . P __ _._ _ 1 ' !:I.::.7.::::..:. -• a .. ... , _ .,:,...=::: , ,.. •. ,,:•.•,:.:: RPPP; -Fr: - - : sie.e.......134.1.-0 - -- Iii ' 11111: E ° .. n .. “ei " • 0 0 •w. jail! _. 02 y - -- N�O... OEeas \111111111MIIIESssO - - - -- (z :le ci: , . 14 ii •- © - - -- cc O - ETL Testing Laboratories, Inc. Reference: 97 *11704 -i Page 9 Issued: 7/23/97 CONTROL PANEL PHOTO NO. 2 General - Photo No. 2 shows a typical control panel. The panel location is described in the manufacturers' instructions. Represents all models as noted below. 1. Control Panel (model 10405 only) - Control Panel: Listed, Garmat, model 10405E, rated 208/230/460 VAC, 69.3/63/31.5 FLA, maximum 46.2/42.0/21.0 FLA largest motor, 50/60 Hz, 3 Ph. Refer to page I7 for wiring diagram. Control Panel /Low Voltage Remote (model 10420, 10461 and 10480) - Control Panel: Listed, Garmat, model 10420E, rated 208/230/460 VAC, 69.3/63/31.5 FLA, maximum 46.2/42.0/21.0 FLA largest motor, 50/60 Hz, 3 Ph. Remote Panel: Part of Listed control panel. Refer to page I5 for wiring diagram. Control Panel /Low Voltage Remote (model 10450 and 10465) - Control Panel: Listed, Garmat, model 10450E, rated 208/230/460 VAC, 69.3/63/31.5 FLA, maximum 46.2/42.0/21.0 FLA largest motor, 50/60 Hz, 3 Ph. Remote Panel: Part of Listed control panel. Refer to page I6 for wiring diagram. Control Panel (model 10505 only) - Control Panel: Listed, Garmat, model 10505E, rated 208/230/460 VAC, 69.3/63/31.5 FLA, maximum 46.2/42.0/21.0 FLA largest motor, 50/60 Hz, 3 Ph. Refer to page I4 for wiring diagram. Control Panel /Low Voltage Remote (model 10520, 10561 and 10580) - Control Panel: Listed, Garmat, model 10520E, rated 208/230/460 VAC, 69.3/63/31.5 FLA, maximum 46.2/42.0/21.0 FLA largest motor, 50/60 Hz, 3 Ph. Remote Panel: Part of Listed control panel. Refer to page I2 for wiring diagram. Control Panel /Low Voltage Remote (model 10550 and 10565) - Control Panel: Listed, Garmat, model 10520E, rated 208/230/460 VAC, 69.3/63/31.5 FLA, maximum 46.2/42.0/21.0 FLA largest motor, 50/60 Hz, 3 Ph. Remote Panel: Part of Listed control panel. Refer to page I3 for wiring diagram. • • ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 I1 Issued: 7/23/97 • WARRANTY INSTALLATION REPORT CUSTOMER: DISTRIBUTOR: CONTACT: INSTALLER: ADDRESS: INSTALLATION DATE: CITY, STATE, ZIP PRODUCTION DATE: GARMAT SERIAL b : !MATER MODEL #: MOTOR SERIAL a: MOTOR MODEL #: CONTROL PANEL MODEL N LIGHTING ASSEMBLIES MODEL 4 PRE -START MECHANICAL: CONTROL PANEL WIRING CHECKED (ALL WIRES TIGHT) _AMPS INTAKE _ HEAT INTAKE _ ADJUST OVERLOAD PROTECTION (AMPERAGE HEAT /SETTINGS) _ AMPS EXHAUST _ HEAT EXHAUST HOUSING CHECKED FOR DEBRIS CONNECTIONS IN BURNER COMPARTMENT: UNIONS TIGHT _ FLAME RODS IGNITER ENDS TIGHT _ RAJAH CONNECTIONS TIGHT _ IGNITION CABLE CLEAR OF METAL _ BURNER BOLTS TIGHT _ BURNER BAFFLES TIGHT _ GAS TRAIN COMPONENTS MECHANICAL GROUPS SECURED: BOLTED TO FLOOR _ BELT COVER IN EXHAUST SECURED SCREWED TOGETHER _ NON- SPARKING FANS _ NAME PLATES AND LISTING MARKS CORRECT AND ATTACHED _ SHEAVES/BUSHING BOLTS TIGHT _ BELT TENSION CHECKED _ MOTOR ADJUSTMENT BOLTS SECURED WITH LOCKNUT _ CAULK: DAMPER ASSEMBLIES DUCTING INFORMATION: ROUND SQUARE___, LENGTH — HOW MANY TURNS DIAMETER INTAKE _ EXHAUST DOES DUCT HAVE TURNING VANES ? SEALED AT CONNECTING JOINTS? TYPE OF CAP: GARMAT GOOSENECK _ OTHER _ • TYPE OF EXHAUST CAP: GARMAT _ GOOSENECK _ OTHER _ DISTANCE BETWEEN INTAKE AND EXHAUST STACK OPENINGS HOW HIGH OFF ROOF ARE CAPS? BOOTH CONSTRUCTION: _ COLUMN COVERS SECURED (SCREWED) IN THE 3' CLEARANCE OF ELECTRICAL PER NFPA 70 _ DOORS ADJUSTED _ ARE COMPRESSED AIR INTERLOCKS IN PLACE AND _ I IINGES PROPERLY SET (WITH ROLL PINS) FUNCTIONAL? (DOORS AND LIGHTS) _ AIR DIVERTER INSTALLED _- ARE ALL WARNING LABELS IN PLACE? _ PIT SUPPORTS (ADJUSTED/SECURED) _ DO ELECTRICAL CONNECTIONS MEET NFPA 33 & 70 _ FLOOR AIR DEFLECTOR PANS INSTALLED STANDARDS? _ FLOOR AIR DEFLECTOR PLATES INSTALLED CAULK: SPRINKLER HEADS _ CAULK: AROUND LIGHT GLASS _ CAULK: SIDE SERVICE DOOR PANELS _ CAULK: CROSS -OVER FROM MECHANICALS TO BOOTH CAULK: BETWEEN MECHANICALS AND FLOOR _ CAULK: FILTER RACKS _ CAULK: TUBING (MAGNEHELIC/DOOR SWITCH TUBES) CAULK: WALL PANELS _ CAULK: ROOF PANELS _ CAULK:AIR LINE PIPE (FOR SPRAY AIR) PAINT TOUCH -UP • GLASS CLEANED PIT CLEANED 04/96 DECALS INSTALLED • I • tD M ID K [� TMIM2 n h _ 0 0 0 O •���_ -• it •• Df.Mlxr o 0 o a iM c IM 17. Ir.. 1 (pV t ! ! y - - - - - - - 3 % 4 ..:1=1.11111 - 0 0 0 0 0! 1 4S • IYO: .117..:711 • WS ri i:i LI L7y fie- Sel y. ; 3-3 a • i H , -4- „ 1 nm o ® OHP ® 10N' 1 7 - }' r.." n'...1 ' ~e - pip S i , . • �-- , i RIP ItRKf - r E n ' i Ea • 0E1 o - -e- T 3" Q DIMES* r LOS tt v0. SLOG f T- - �/ - •n[n f..: 0 iONw �,T l' IK-LY9 1 I ry KIIIP CO ' 1 _ 7 I �"F jr Uunz 0 v C �Ti 1� /I Ioe 1 '� o ., - .l 0 d � f z.x L -d O 1,q ' ,o.em. cmn.Q. yr L a 0 1 G.S IMM SERVO R/31171 T` ,cv r IMC r v .c E4 �e 1 Iii J -H XL J' H V .-- T r- _ .— __24.— N 0 m s.rsec � K —s f f7o- i [ TO•r..nw gyp f L -,;(50 - - - 'f a e ] 'dvt. t'T • I r g r ,s e - _ =e ; - l • 1 - - - K ...+ J 41 .0.----- .C TWM N. Fy TA VI I rK*acont - O'.4 =p -0- 7.__ no. �s..ry o-.R ft r -:f rr.wrn 7 � - I HOURVETER� no v. torn= T.rc • n NOTES. ° u THE MOTOR SUPPLIES MUST BE CONNECTED TO AN APPROVED DISCONNECT OR LISTED BREAKER BY INSTALLER . _. vee• f ALL VIRE CONNECTIONS TO THIS INDEX. PANEL MUST BE COPPER VIRE VI7H AN INSULATION RATED 60 RA- CHANGEOVER RELAY v2- CHANGEOVER DELAY TIMER F{ DEG C OR MORE RL- LIGHTING RELAY M1- INTAKE MOTOR torwrc. vnue..a rrovlrcm MY m PHI- INTAKE MOTOR RELAY M2- EXHAUST MOT DR a•••• R• C • CO ALL COMPONENTS U.L. LISTED RM2- EXHAUST MOTOR RELAY MGV1- 1ST MAIN GAS VALVE Co Co OR RECOGNIZED RBI- BURNER CONTROL RELAY MGV2- 2ND MAIN GAS VALVE R82- BtFNER LOCKOUT RELAY � �5 0S61,1 X580 „iMa01„ , . gy p p ' En02.0.cp CO ALL TERMINALS DESIGNATED AS - KI- TEMP CONTROL RELAY O cane'- m .. BEING MELD VIREO MUST CONFORM SMI- INTAKE MOTOR STARTER _ TO NATIONAL AND LOCAL CODE SM2- EXHAUST MOTOR STARTER . _ J REQUIREMENTS VI- RECYCLE DELAY TIMER '^� ® m .11=&Itria6" S,SA man Y ... N MOT c K W . to • I CD M ►t G .0' 1 <• ,1 i r. NUKE CD0 flA LI, e..... • 1M..... N 1,..F.) n. o % - - - - ;Op - - - 0 0 0 0 tamp ..�' •M L q � I ... C[NAVS . A.00 0 O , ®, 26 „ T 4J A . r L - - - -.T — — — l0 fp a o o e n �� _ - K L ,� i S M �. R i 3. .II 111 '' if M = _ = _ - - ®10 HP (1111° HP o:LO i • �� " -, = H �ypcw vP•• r. . t•, I -�.. I nw.. ,, f - � - - - & T i - % • n.tv.i _ 1' 17 pp C1, m 0 VA OWAEL 1RARS M ) m .UIPCR (T' • i-i-u .+ it 1CR LIDOS ((I • eta VOItS , 1 'ppy[R • Y© H M t RM 0. F- r r • IK SC ROTOR S w 0 HOURYETE 1j 0 -_ ° c[c fT y 0 , L e- moo--- hs I ROVER W I 01 1 .. m I I RCTUIM •12 '[ ` [ M 41 p__ 1�u rw PVT ✓ �1 NOTES: INDEX' . VI THE MOTOR SUPPLIES MUST BE RA- CHANGEOVER RELAY CONNECTED TO AN APPROVED RL- LIGHTING CONTACTOR no Itch eo. AI) DISCONNECT OR LISTED BREAKER PHI- INTAKE MOTOR RELAY BY INSTALLER RM2- EXHAUST MOTOR RELAY ALL WIRE CONNECTIONS TO THIS SM1- INTAKE MOTOR STARTER A A MUST BE COPPER IONS WIRE SM2- EXHAUST MOTOR STARTER VI- RECYCLE DELAY TIMER . WITH AN INSULATION RATED 60 V2- CHANGEOVER DELAY TIMER COMPUTER DRAWING PRODUCED TOR. H DEG C OR MORE Ml- INTAKE MOTOR OARLATI9A R M ALL COMPONENTS U.L. LISTED N2 EXHAUST MOTOR Da,..00, co 1 M ra. ISM) m .v OR RECOGNIZED 10550,10565 0 �W:°: A. ALL TERMINALS DESIGNATED AS BEING FIELD WIRED MUST CONFORM _ 1[R A.M.. ., . J TO NATIONAL AND LOCAL CODE ---^A• sTmur w 't w REQUIREMENTS • A '°'""'°R'"`0 °: , r now'• N L.+ to -.1 I x1 m M m H 3 ?. 3W FEEDER FOR v v m 10HP MOTOR 120 VOLT, 20 AMP G H� 0 SINGLE PHASE J�+ .-----.. O C 0 10 y I O V 20 ,,/ ,o • INCOMING RORER LUGS 9.41 v O • • • • RL7 I , RL21 - 1 y 6 •P 1 1 1 1 • EM SM1 I _' 1 1 1 1 • - - S 2 21 124 5 ■,0,3 -- ,e" RIGHT r4 13 LIGHTS 1, 1 " 3 6" r CD SM1 - -1 FT m ,_. , , L GHTS �/,6 rr 1 I y - - �(1- - - A L . 0" ,_ I , 1 I 1 1 I 17 - FAN - 1e ® A2 " ti 1 �C� — - - - - A, H C1• � I. O MOTOR ° . C A , 0 „ 19GUN DAMPER 2' 1 a LEAD - 0- - - -9 4 y„ rt TuINALS , 0 1 [a HP K TYPICAL OF 16 F, Aik , 4 -TUBE LIGHT FLOW 0 FIXTURES SWITCH PUFF m RR 1 21 SWITCH 2 -� .�- ^ gyp • • al iJ . 7 7 H NOTES 1 V1 4 n 0,3 t � 1 , - I0 , — — THE MOTOR SUPPLIES MUST BE RRI 0 0 CONNECTED TO AN APPROVED 7 3 s,1\ , HOURMETER DISCONNECT OR LISTED BREAKER ;-;11 I „ I O2 _ BY • INSTALLER r RR 1 COMP, AIR SOL. ALL VIRE CONNECTIONS TO THIS 12 Jf — — - I PANEL MUST BE COPPER WIRE I WITH AN INSULATION RATED 60 „ DEG C OR MORE INDEX. DAMPER SOLENOID H C OMPUT ORA6!"C PRODUCED MR IL ALL COMPONENTS U.L. LISTED CARRAT USA GAMIC LISA m R1.1- LIGHTING CONTACTOR OR RECOGNIZED " • ° 1 ' Ca RL2- LIGHTING CONTACTOR 85S A -'° CI. RRI- CHANGEOVER RELAY ALL TERMINALS DESIGNATED AS 10505 Pa 1'x'1 „ � � e • SM1- MOTOR STARTER BEING FIELD WIRED MUST CONFORM ID NPnm"Inos •• M- 10HP, 3PH, MOTOR TO NATIONAL AND LOCAL CODE m.m R n, a VI- CHANGEOVER DELAY TIMER REQUIREMENTS J wn ■ sx[raoK STATION nMS I ASASIQ ,ort"AIC s,¢ Drrm, aO an = •c I wt.,. N W v I >~ CD M m I n n.. �� . 0 t �T..E m ° o 0 0 0 ' n .w • mi .. .1111111111 • I Ct wUST 9 ° o a ° L, ® !! n . IY 7 7'.G it .t. J �.y = S S + _ _ _ _ � _ _ _ �,, C ° ° ° ° : ' R!,_ g V.1 CS t ME = • w ra>7 t • " FAQ S t7 IA to L � . If. SAU a H * ii . DOW( Pdm 4. 0 HP ® TX 1 t ` Q mar Y om - - -�- : I r =7, o .0 � 1 5 HP ( I -.. .1--,- LT .'!":73. , .• t • C!_ r A WK D1 BR y r c f , Z J I ti t 4 ..11.1---24- - - - - w©a - - - '" I M 1 1 I } _ ' J l ' v ' "nrcR AC ..z a� u amo f - I - -/ I ' a �o l :o a r " n rt I p v d ,r I t A .0 w L Irlan L. t 1:fr__ J 11 I .CV r J I.0 SER i IIER lU — a.= .R., 1411v0 arm . - c` H Er r I � -� o— - "' UT O OCC n 1 - lip - �-- -- o--- ' --4.--- w {� 17e - -.f E n1u. . D•-- -� I PDVER - Cl — <r I- v,O - °e . O I n • I .1, 1 i1 '.F }' / r.p I i - - g I 1 , •,L':+• m - s = ' I 1 I , K l u . AIR Ca r oID , r _ 091 91 J v2 .......„.....t. I "I____.,,_,„__. ..'-.. •RICC[1.P1[ � R ny Ell S1 o•T A 66G . ."..1=-4.- - - -O i.r - _ •- 0 MOTES: .... ESA v. MEWL 1...6 a.. R° THE MOTOR SUPPLIES MUST BE Imo-- -I F - - CONNECTED TO AN APPROVED •„ I r _ DISCONNECT OR LISTED BREAKER y � �HOURME7ER S BY INSTALLER ALL VIRE CONNECTIONS TO THIS - r• v.... _ PANEL MUST BE COPPER WIRE • H WITH AN INSULATION RATED 60 INDEX CO DEG PRO°ucc° roa � m RMl INTAKE MOTOR RELAY SM2- EXHAUST MOTOR RELAY DEG C OR MORE CAE T USA MMM v • ALL COMPONENTS U LISTED RM2- EXHAUST MOTOR RELAY VI- RECYCLE DELAY TIMER iliS+`••> m a'° 0] OR RECOGNIZED RA- CHANGEOVER RELAY V2- CHANGEOVER DELAY TIMER ,. ,., ,., ,. '".I,.at m RI.- LIGHTING CONTACTOR Ml- INTAKE MOTOR .. ...neon wry ALL TERMINALS DESIGNATED AS RBI- BURNER CONTROL RCLAY M2- EXHAUST MOTOR _ BEING FIELD WIRED MUST CONFORM R02- BURNER LOCKOUT RELAY MGV!- 1ST MAIN GAS VALVE _ STD et K1- TEMP CONTROL RELAY MGV2- 2ND MAIN GAS VALVE "m. = VT 3 TO NATIONAL AND LOCAL CODE , ,, •�o*�g � nre � \ REQUIREMENTS SMl INTAKE MOTOR STARTER n.. s SSW P I elm .T• N ■ 1.4 W -1 a XI m M CD Ii m , 3PH, 3W FEEDER FOR 720 VOLT 20 AMF v 0 Shp and Shp MOTORS SINGLE PHASE J K, 0 ID a o C O0 10 i EXHAUST l0 O` 9t)p - o x mamma 201 / 1-. PON. R O SM1 LUGS H INTAKE H °"O fy 0 Q - - ° " +P t t u SM2 H I O 1� RLI ' ' a I I 121 ` 7 I EM SM1 s H L H u LIGHTS m SM1 - -�- SM2 1 - - - 1 - <IP - - AD.? `N m 1 I 1 p - 1 1 I i s - FA o - - - •• " Alen N N 7Q I I 1 i 1 1 ' PT - - - , ,GUN DAMPER H t7' +- at O MOTOR C. 4 G H I. �N ' - - � - - - A, A, N PT • LEAD MOTOR p' LEAD 7T TERMINALS TERMINALS 0 Shp 3np TYPICAL or 8 4-TUBE LIGHT i i ® '•x W ® 0 FIXTURES C3° m SWITCH SOLENOID to STCH 0 ` r � RR7 THE MOTOR SUPPLIES MUST BE 91 _ FLOW • H - 5M7 .. 0„ 1 0 : HOURMETE , NOTES, '- I i Sj o- � T S ° • 2 © N o �l 0 '= L_ \ ""� \ -- 1 0 1 s a 1 VI 4 p INDEX. CONNECTED TO AN APPROVED 12 k.c DISCONNECT OR LISTED BREAKER RL1- LIGHTING CONTACTOR BY INSTALLER O RRl- GUN DAMPER RELAY 3 ALL VIRE CONNECTIONS TO THIS RR1 � DAMPER OLENOID 2- INTAKE MOTOR STARTER SM1- EXHAUST MOTOR STARTER PANEL MUST BE COPPER V1RC F1? t VI- DAMPER DELAY TIMER _ _ _ VITH AN INSULATION RATED 60 32 3 - VI- D C OR M ORE H MI- SHP, 3PH, EXHAUST MOTOR LVYAI7[!5 ux.+mlc Irnoosxm ,9t[ m M2 3HP, 3PH, INTAKE MOTOR GAMUT OSA APIIIAT l0 ALL COI�ONENTS U.L. LISTED ;� M OR RECOGNIZED ^" II1 ° - ' ° ID ,AI MI) ,a a - ALL TERMINALS DESIGNATED AS 10450 & 10465 m 02,7177117 a BEING FIELD WIRED MUST CONFORM - Ill WS TO NATIONAL AND LOCAL CODE rlllruAnat rrmox ��'. • .� i u ps v REOUIREMENTS Illnuu IOm.TC m 61T101 can erg t. . v.... \ Jr.. i A.. LV W lD V P .e L • :■ ID M ID H N NOTE: THE MOTOR SUPPLIES ID MUST BE CONNECTED TO AN G V H7 Q APPROVED DISCONNECT OR % 0 USTED BREAKER BY INSTALLER T20 VOLT, 20 AM u• 0 10 3PH, 3W FEEDER FOR SINGLE PHASE 2 0 � • ■ to --] Shp MOTOR ,0 * SW H J s s . r 0 I I • • ,P. INCOYNG I I I i EM 1 b SM1 r POWER RL1 ' ' • - T '1 1" P'v „O,s — — —5,c. I I [t3 • • , LIGHTS I-3 __ r t __ /0,2 p N 1-3 ,, FAN m -- �C>- -- 4 ,e M w7 52CN Cr „GUN DAMPER W SM1T- - - ,. - -� o ,� �N r I I W . I I H l7 I I FLOW � ��F 0 I I RRt t95NA z WIT a t I - -, ,3 01.X WE R ` NIRC *. C'r I I 0 - - - - TYPICAL OF B sw,Cw swR1 K 6 -TUBE LICHT F` MOTOR 's FIXTURES ID •• - - m ,! G 1 V I 4 TERIAINALS 0" t' n I " O 5np SIJI \ , HOURMETER a H 122 3 © 1 RR 3 • � I COMP. MR SOLENOID INDEX+ NOTES 20 RR1 let_ SM1- MOTOR STARTER THE MOTOR SUPPLY MUST PE CONNECTED � S, r 1 DAUBER oL[NOiD RLI- LIGHTING CONTACTOR TO AN APPROVED DISCONNECT OR LISTED RRI AUTO GUN DAMPER RELAY BREAKER BY INSTALLER i- VI CHANGEOVER DELAY TIMER 11 ALL WIRE CONNECTIONS TO THIS PANEL MUST COMPUTER munxc PRODUCED Iva ^^ m BE COPPER WIRE WITH AN INSULATION RATED EAR MAT USA tl 137B+T USA m 60 DEG C OR MORE ••=1.17 p nr �m1 •a -•ne ID ALL TERMINALS DESIGNATED AS BEING FIELD 1 0405 wan m„ O. WIRED MUST CONFORM TO NATIONAL AND LOCAL CODE REOUIREMENTS ,,,,,m,r - '° PREPARATION eTAT70N - c rt m . J ELECIMED. ten:. nn m,■x N.M. n. me re. Ono • n.. S. .1....4C I , 'mono N W W -3 • '.. c., ETL Testing Laboratories, Inc. Reference: 97*11704-1 18 Issued: 7/23/97 - - - -- ------- ‘ -,.. . ei d ,..-.;'' ;S '1- 1- - , ,,I ,, It 1 , A , 1 V --.` , .k:, -.7 - F.:1 ; ..„• - ,,•' - .. , -. 1 ) ,, , , ry tr. ,14. .1•• , .•'. , ?.. k . , • ut t' , ,x-2.',. ''',1.1.4.•".14- ,, , . „' ' • .,..`: 'A:: / '- `'A ', ?,,,,,,:,--„, I, ''...'; : • '.;. - i .--. -..•„..-ir "(••••...4 - c- i 'll' 4 f• 1 ;'''. 1 1 : ) ! 1 1 , r L1 '..1 / ' e ''...-•-!"' - , •,- ,,, ,,,---- , r i i i- i - ' ; ''',.. ''-• , 1. . . - . ,.- .. P , ,„ ak, i • . , -t ' ' 4 N...., i',./ , , • . . . ,-,•-• • --.-,-- .,-,, ...._--'. r• Lob Safely Supply Inc. Reorder No. 6&4 0 ''' , • t, • '''.„ ,. .‘ ,, '...,,,e? , r. u. .......• .. /N. .1`""1. I f ''' ' lt ''''. '' '. `• ' .-.. ' ' 1 • MI t' ""''' '4. r" P. --, = ' 1 N v. , •,' -... ' 0 ' '' '. -t ' ; ` ' • .4 % , • L " 't i V IL f . , . • • I '..,- '' l" l 13 • '.. u. • ,--- . r ------ , , . . . .....t..1-$i. . -..-. -. ' ' 4 , .'-: '" ' • 'I ,-; ''' , J l ''. ,' ' . . . : . ".,.', •,,.. 4 : . l I .,,-..;;', c .-.. . '' • 7 -. ,k!1'','• (,:','". (A; '-',,,. ,,`- ,';''','' ..,- ,,,:,', -,.....--;,•• ,' ' -..,...., - '-‘‘`,' -r ., ' •I ' 2,i's -- - ), . , .. •"-s . ' "A.11-;4' . ,"; - 0 .' : - .:.'x '..r'''.1.-- :-''•:. ,"$-:• *.- -,'„, -,,,l ',',..;;;-,-.)tiq , - - ' FAILURE TO HEED THE FOLLOWING COULD RESULT IN , PROPERTY DAMAGE, PERSONAL'INJURY AND/OR DEATH. Approved respirators must be worn. _ - Use caution when loading/unloading vehicles onto grated flooring, ow , and/or when using ramps. . . Grated floor areas and ramps are designed for vehicles with a gross ' vehicle weight of 6000 pounds or lase. • ; . . , Refer to Garmat Operations and Maintenance Manual for complete , sanding station/preparation area operation and maintenance procedures. • — . . • ETL Testing Laboratories, Inc. Reference: 97*11704 -1 19 Issued: 7/23/97 • . Z .4, qr ,d11.116 ;:, ' • '. W • 0 mom. .. Z... Z 0 , . i- 1 z ., .v.,..,,::"•4N A ■ CC 0 ' 03 > ......." ', •, i Is" 0 1 i 0 i 11.1 •-• i , ..— .,,.. ... '; : , 0 ' • . LL z . 0 W .,..; 0 C4 -, .4 ...... -••;,- . e4 , ,•,4;, , w,p-4' f.i1,•,...:' .,..,:;.,.. . r 't, ;.!... (,,,C:'7..... ' -:•::'•:,::: , ",i . „ '!:tr14- ....'.. .."4.1.64...A.e.:,,....!..,' .-• .- , • , ., A. ::.:i t !. +'''; • Qt , ''?..:•.,,,,,,,......— • ' :.; t, .,:!•:!,--;-!-.••1'40-:•51-.54 . ... i • ,-;4Z,-....,:•••:',4,-.• . ... . - ;-0" ee:,7 '..\'''' • . . .;T-'2- • . !c F., ....7 .4 1•••?;c7.1:a". LLV; 4 - ,..: .-. 1 '.1. - . , ',..; • IL! „ ..i- , '" ,, r.."::!: r ••,-.'::,%?,,"' .' . '. . ';'0,,,!.r '...x.,,...4 7 ,..: ..'", . • - - V.:.kl-. • . ■.,..,;" .: --:-.- .. . '- . ,,,, t z e ,-. w 1.. 2 • - • , . ' ; .. C r v,',,I.I.,,,v,1'..-4.:•lqi! Afg.,,. "'-- ' , -,r iT'..• •• ' '', ' ,.!,,,',- ,•!„ :t..,,,.! . t.4.i -. -'' : 1N: -,..- .-' ' :. ' .4 : .': r • ';':i ' -'.' 'eel-3;e • ' -.. , '.,' r A '''.;,.',., r - '-'.:- , r:::,.'„-,1.`'.. : (■,,,' 1 '1 : +.• ,,i,t 0.- : s ' , ; . • , !-- .. ...■, ,, • ,, _ , ' 'y :'I. i 2.' , :'- , '? ... :;?.•"+• -, ':.' : :. : ■,''':•': . '-''' . . . k.•:',..-:-:',,i.::'..Y•'•. -•%,''',..'1 ,... .. . . • . . . ' • • • + J ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 I10 Issued: 7/23/97 '.:.,•;._arb¢ -$ • FAILURE TO PERFORM THE REQUIRED LUBRICATION WILL CAUSE PRE - MATURE FAILURE OF THIS EQUIPMENT The moving mechanical portions of this equipment require regular lubrication at intervals not less than three months. The items requiring regular lubrication include: hinges on doors, dampers and filter screens. If you are unsure of which items need lubrication, contact the _ equipment supplier. If moisture Is present, lubrication may need to be performed daily. A 9 L1,yyti`: 1� '7.: ;�_ 'I.' - { ..ti.' :i. . 4 ..Y ^�1f.�}h III •u , - , i �•�:ri,'r. i \1:... �N' � :CA ' �:. >i,:•wr • ':ii: H:+i.. .•::a ;;: .Mry , `yam .. • REFER TO THE HEATER RATING PLATE FOR DETERMINING THE MINIMUM GAS SUPPLY PRESSURE FOR OBTAINING THE MAXIMUM GAS CAPACITY FOR WHICH THIS HEATER IS SPECIFIED B • 1 ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 I11 Issued: 7/23/97 A B f R , -+ i ti �•� 1 �v�. -r ;v S '.r.t. �-. 4 r 7 y �fia � rL� r :'.�a of i FF Y ^ -, .,,,,w., tt C ... R 1 f i 1 S �, �� w")` 7 rt ` •f :f ! ` .1 i ry � . � � � d y 1 � ' � [ue L s •, , A .5 ,` 1 1 IE A L ' � L ,� �1a .fit 1. nc: F I , t .4'. ti X1� ?Nd:.1a ,:v'li� MM TORQUE TERMINALS FOR MOTORS ALL WIRE CONNECTIONS TO THIS TO 12.4 FOOT POUNDS PER INCH (OR EQUIVALENT), TERMINALS PANEL MUST BE COPPER WIRE FOR CONTROL AND LIGHTING WITH INSULATION RATED TO 2.3 FOOT POUNDS PER INCH (OR EQUIVALENT). 60 °C OR MORE. - C �. A' ( L ..;; 1 �.' A� rdl �. 1 r . 1 1 G :1 . t. �t�ri z i'i ft� { 1 % t� tl +1i �� 4 f ,CS. a s .. •r t t r � , :.:�+� F 1 :'1 it , .t.. e { ` 1 \\ ` r ' S IC; ' l 4 � r :,, � 81 . ) 1 rr � �, ,� ,P if 'l 1,1 ri 1 k I a n I. ,' p�11 ` 77TH • M I/ �A l 1 I' ,• 1 ?: _7i `7Cti.1 fit. r. �,. 1� � ..Ii.. T. C{ �.I M. .�IlG.1 ,.+ ,/ 1 .1. .1,�..0 .{ .11 I . .1. Y. . .tl •... . ... .. ... - Hazard of electric shock. This panel has more than one source of power. Disconnect all power sources before opening electric panel. All field wiring provided must comply with local - - -_ ow codes, or in the absence of local codes, the National Electrical Code (NFPA - 70). Local fire or building codes may require fire protection - check with local inspection authorities for requirements. ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 I12 Issued: 7/23/97 ' h X11 pil a 1114,.1 � •�' �1 �� /I � I 44 44t4t Vi. II .,. III \r \II \II • 10461 10465 10480 , -*- 4 , � cam)' . ' ► s 1 ... F • r � , I I j, f ► . � � M k+. �� I � I�}F � P. F.r �- , _ 1 r lip _ � ► �.::r. • I 0 Vii %kr I 10405 10420 10450 4tP 0,d'a 4 40 4111 kb . Ih 17 � r 4,y 1 1 4 '� `, o ff, II I , : , - i. Am t k i � � I II 10550 L 10561 10565 I. 10560 >�I i1 it • .jjlli rte ' 14 r V III � A 10 1 4. F . 1.., �.. 1x w ' ri�llh � ` .'3'�ik t I F ,..a idU �, I�/ ► '� � - - , - . :1il � � , 00 41 10505 _ 10520 ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 I13 Issued: 7/23/97 • • � lo] 1.I. l t• I- . t i 8 13 I i .. 1 ' f6 11 9 1. I i i \, - t - - I i ii 1 .. - .. .. 1 MI = NI U r•N IIIII c /•46 1 O / L— - -J 0 ( I O 1 � 7 _J l ) N ' r c \ - I- t - - - � 0 /�I • 1 . — 1 N 1 I 0— - �' O ! . , ` , . i '! ,a� I _ Eig! N I 1 I ...J / L' \ N i I— — - — — J ( i U I l F $ 4 . Ia ETL Testing Laboratories, Inc. Reference: 97 *11704 -1 I14 Issued: 7/23/97 OM �eeg C ` , C ' a` : .• SIX11 r '-1:, - - - --- • . ( rt • -I- \ -----1 ■ � \ I 1 e e I — I ' l l I . 1 - e 1/4 - cn ¶ C ■ I I I 9 ,_ L____J l y U . t i � 0 — - - - - -- -- uu l N MN MI Xft _ / C ou 1 1 p / a o 1 1111 0 4av 11 L..■.. o V I I / — L._ ■�. L _ / vi 0 ii0— — • • 11 i . . .. ,Z-U-1 9 5(— a ‘ ,7 / ..... 9350 se-4- -- / --- ,.--1 4- 2 0/ I --- ,.. . , j.. .74 , .,.. ..• • . • ..fti-.4 . , • , ..../. ,z#,,p . . it wu -• i ...li ,e . ,...-,.i.fi.,-v ; ,.v. e -..t.t .. z...„.. , jr — 4,1 :■::,‘,..% ' %AI ..... ji tV .s . ,...... • t eAl - ..r... t :‘4:11 . t.. 1. 1 1. S ..?..;(j.F., 3...6 ..,.,e1A. 4.2.71.i:11f:1 :_.:!: 4... ..:.;:::-..;::".'&.:1...:3•■•• ti , t - ,- „I /5 .t4p. ,,...„ • "I , ,?.4 .:-.-%, .... -.,,,.., ..,... , ..1.1 .) . . f r 4 rt..,,,z,:. ,-PA 4 : t. ', " • '' ..-. .- •. .:. .: -I: : • ! 1 ,47;,- . :t.. 14 5 . ..,-- . -• ...., . .:. -..-!41 - , ,,;,.,,;. , 7-1 . .." ...IA: .1 -, -7: ..., : ,...: 44g4 .‘ ,-c.:i •ci. ,,' .. n., - . • ..a;/ .rc'-'■-' ...t,j ,.-5.: 4v r .i. . c ..' ,-. A .P.7,1Wir..5■-1,,,i.;,.,ifp;ii; a•-• ., A ez.• . 5 SINCE 1896 ETL Testing Laboratories I•1I■1IIII■ ' ETL is an independent testing and certification organization. CLASSIFICATION REPORT ETL TESTING LABORATORIES, INC. S . ,Ct ,,,; 1089 EAST COLLINS RICHARDSON, TX 75081 Order No. 116907 -301 Page 1 of 4 Issued: December 3, 1996 CLASSIFICATION REPORT NO. 567495 INSPECTION, TESTS, A.ND EVALUATION OF PAINT MIXING ROOMS RENDERED TO GARMAT USA, INC. ENGLEWOOD, CO GENERAL: This report gives the results of the inspection, tests, and evaluation of Paint Mixing Rooms for compliance with the requirements of the Standard for Spray Application Using Flammable and Combustible Materials (NFPA 33, 1995 Edition) The sample was provided by the client and tested at an installed location in Denver, Colorado, on August 13, 1996. Participant: GARMAT USA, INC. 1401 W. Stanford Ave. Englewood, CO 80110 Contact: Mr. John Jurasic Alternate: Mr. Bruce Williams Phone: (303) 781 -6802 x206 Fax: (303) 761 -8037 An Independent organization testing for safety, performance, and certification. Al services undertaken subject to the following general policy: Reports are submitted for exclusive use of the clients to whom they are addressed. Their significance is subject to the adequacy and representative character of the samples end to the corncrehensiveness of the tests, examinations or surveys made. No quotations from reports or use of ETL's name Is �I'G.: :�(i_ _ .. . rte _ _ ETL Testing Laboratories, Inc. Report No. 567495 Page 2 of 4 Issued: 12/03/96 CONSTRUCTION PRODUCTS COVERED: Paint Mixing Rooms, Model Numbers 99920, 99925, 99930, 99935, 99940, 99945, 99950, 99955, 99960 and 99965. MODEL SIMILARITY: The model numbers refer to specific booth dimensions and number of lighting fixtures. Refer to the table below: Cabin Dimensions Exterior Dimensions Interior Dimensions Number of Model (WxLxH in ft) (WxDxH in ft) Licht Fixtures 99920 6 x 8 x 10.8 5.5 x 7.5 x 9.0 2 99925 8 x 8 x 10.8 7.5 x 7.5 x 9.0 2 99930 8 x 10 x 10.8 7.5 x 9.5 x 9.0 2 99935 8 x 12 x 10.8 7.5 x 11.5 x 9.0 3 99940 8 x 14 x 10.8 7.5 x 13.5 x 9.0 3 99945 8 x 15 x 10.8 7.5 x 15.5 x 9.0 3 99950 8 x 16 x 10.8 7.5 x 15.5 x 9.0 4 99955 8 x 17 x 10.8 7.5 x 16.5 x 9.0 - 99960 8 x 18 x 10.8 7.5 x 17.5 x 9.0 4 99965 8 x 19 :< 10.8 7.5 x 18.5 x 9.0 . PRODUCT DESCRIPTION: The products covered by this report are paint mixing rooms that are no larger than 150 square feet (inside dimensions) and contain a maximum of 300 gallons of liquid. The mixing room is erected on site and permanently connected to the supply source. The ventilation from the room is cross flow and ducted to the outside of the building the room is contained in. The lighting is exterior accessible only. A pit covered with a floor grate is used for containment of a liquid spill. ELECTRICAL RATING: The units are rated: Motor Circuit: 115/230 VAC, 8.6/4.3 FLA, 50/60 Hz, 1 Phase, Intake Motor. 115/230 VAC, 4.6/2.3 FLA, 60 Hz, 1 Phase, Exhaust Motor. Lighting circuit: 120 VAC, 20 Amp, 60 Hz, 1 Phase. • ETL Testing Laboratories, Inc. Report No. 567495 Page 3 of 4 Issued: 12/03/96 PERFORMANCE NO. 1 A representative sample of the product was tested in accordance with the Standard for Spray Application Using Flammable and Combustible Materials (NFPA 33, 1995 Edition). Results of the tests indicate the specimens conform to the applicable test criteria. The following tests were conducted: Test Performed Section NFPA 33 • Airflow Test 6 Test Performed Section (UL 507) Temperature test 33 • ETL Testing Laboratories, Inc. Report No. 567495 Page 4 of 4 Issued: 12/03/96 CONCLUS ION Samples of the product covered have been tested, examined and found to co:-.ply with the applicable requirements of the Standard for Spray Application Using Flammable and Combustible Materials (NFPA 33, 1995 Edition). Report Approved by: In Charge of Tests: 4 John Knecht, P.E. 1 Kenneth Hansen K72.) Staff Engineer Engineer 1 Inchcape Testing Services !AUG-18-97 02:09 PM GARMFaT.USA.INC. 3037812683 P.01/01 • • 0 AUTHORIZATION TO MARK This procedure authorizes the listce to apply the ETL mark to certified products when made in accordance with the accompanying descriptions and drawings under the conditions set forth in the Listing and Labeling Agreement herein: Participant: GARMAT USA, Inc. 1401 W. Stanford Ave. Englewood, CO 80110 Manufacturer: GARMAT USA, Inc. 1401 W. Stanford Ave. Englewood, CO 80110 Reference #: 97'11704 -1 PRODUCTS COVERED BY THIS MANUAL MODEL DESCRIPTION STANDARD(S) 10405, 10420, 10450, I0461, Closed Top Open Front Paint NFPA 33, 1995 Edition 10465, 10480, 10505, 10520, Spray Booth 10550, 10561, 10565, and 10580 This procedure, with all revisions, etc. is the property of Intertek Testing Services and is intended solely for the guidance of the listce and the representative of Intertek Testing Services, and is not transferable. ENG INEERING OFFICE: INTERTEK TESTING SERVICES NA, Inc. 1089 East Collins Blvd., Suite 200 Richardson, TX 75081 TEL: (972) 238 -5591 FAX; (972) 238 -1860 AUTHORIZED BY; DATE: • fi Ore • g 3 so � • j t SINCE 1896 • • ETL Testing Laboratories, Inc. ETL is an independent testing and certification organization. LISTING REPORT ETL TESTING LABORATORIES, INC. SINCE 1896 1089 East Collins Blvd. Richardson, TX 75081 Order No. 97 *1729 Page 1 of 4 Issued: March 26, 1997 LISTING REPORT NO. 97 *1729 -1 INSPECTION, TESTS, AND EVALUATION OF ELECTRIC LIGHTING FIXTURES FOR USE IN PAINT SPRAY BOOTH RENDERED TO GARMAT USA, INC. ENGLEWOOD, CO GENERAL: This report gives the results of the inspection, tests, and evaluation of Electrical Lighting Fixtures for compliance with the requirements of the Standard for Electrical Lighting Fixtures for use in Hazardous (Classified) Locations (UL- 844, Eleventh Edition) The sample was provided by the client and tested at ITS Richardson, Texas and Atlanta, GA facilities on March 4, 1997. Participant: GARMAT USA, INC. 1401 W. Stanford Ave. Englewood, CO 80110 Contact: Mr. John Jurasic Alternate: Mr. Bruce Williams Phone: (303) 781 -6802 x206 Fax: (303) 761- 8039 An independent organization testing for safety. performance, and certification. All services undertaken subject to the following general policy: Reports are submitted for exclusive use of the clients to whom they are addressed. Their significance is subject to the adequacy and representative character of the samples and to the comprehensiveness of the tests, examinations or surveys made. No quotations from reports or use of ETL's name is permitted except as expressly authorized by ETL In writing. ETL Testing Laboratories, Inc. Report No. 97 *1729 -1 Page 2 of 4 Issued: 3/26/97 CONSTRUCTION PRODUCTS COVERED: Electrical Lighting Fixture for use in Paint Spray Booths, Model Numbers INT200, INT208, and INT400. PRODUCT SIMILARITY: The models differ: model Size (inches) No. Fluorescent Tubes No. of Fall4ts INT200 66 -3/4 by 20 -9/16 2 to 4 1 to 2 INT208 84 -5/8 by 20 -9/16 2 to 4 1 to 2 INT400 104 by 20 -9/16 4 to 8 2 to 4 PRODUCT DESCRIPTION: The product covered by this report is a electrical lighting fixture that is intended to be used with a paint spray booth; with service access from the inside of the paint spray booth. The electrical lighting fixture will be installed as an integral part of the paint spray booth cabin. The fixture will be supplied with an interlock that acts to shut off the spray air supply when installed in the walls of the paint spray booth. The electrical lighting fixture is permanently connected to the supply source. ELECTRICAL RATING: The light fixtures are rated: 120/277 V, 2.92/1.28 A, 60 hz. ETL Testing Laboratories, Inc. Report No. 97 *1729 -1 Page 3 of 4 Issued: 3/26/97 PERFORMANCE NO. 1 A representative sample of the product was tested in accordance with the Standard for Electrical Lighting Fixtures for use in Hazardous (Classified) Locations (UL- 844). Results of the tests indicate the specimens conform to the applicable test criteria. The following tests were conducted: Test Performed Section UL -844 Temperature Test 46 Atomized -water Test 47.4 ETL Testing Laboratories, Inc. Report No. 97 *1729 -1 Page 4 of 4 Issued: 3/26/97 CONCLUSION Samples of the product covered has been tested, examined and found to comply with the applicable requirements of the Standard for Electrical Lighting Fixtures for use in Hazardous (Classified) Locations (UL -844, Eleventh Edition). Report Review by: In Charge of Tests: Gilbert J Diaz Arnold Schnuelle Manager Project Engineer . . . . . . , - . . . • . . ' . . ,_ .. , . .... ... " • . -- ,. ., . • ,. _ • • • . " , • . • . ., • ..._• • ,.. . ,, • )-' • .. , • . -. , . . - . . - . . , . . . • • . - '. • ,.., . • . . . . . .. . - . . . . „ . . • , . , , , . Se . . . . . . , . • g . . es ....• ._tin ap e T _... . c I. _........_ In c h ... . • • . 1 • . .... • . . • .._ . , • .... . . . . . . . • . . . . .. . . • ..... _ . ... . . . . . . . , ... .. . _.„. , . . . _ ,, • • • . , . , . , • . . .. . , , . • . . .,, . ' . • .•. • „•• • . . • ... " . .... ' . , , .•