Permit w A lb CITY OF TIGARD MECHANICAL PERMIT gilt DEVELOPMENT SERVICES PERMIT #: MEC2005 -00192 13125 SW Hall Blvd., Tigard, OR 97223 503 - 639 -4171 DATE ISSUED: 4/29/2005 PARCEL: 2S101 DC -04603 SITE ADDRESS: 07405 SW TECH CENTER DR 160 ZONING: I -P SUBDIVISION: SW COMMERCE CENTER LOT: JURISDICTION: TIG Project Description: Install (3) gas packs (3) duct systems,gas piping,exhaust fan,modify (4) duct systems. Valuation: $24,000. CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: COM UNIT HEATERS: VENT FANS: OCCUPANCY GRP: B VENTS W/O APPL: VENT SYSTEMS: STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: _ DOMES. INCIN: LPG 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: FIRE DAMPERS ?: 30 - 50 HP: REPAIR UNITS: GAS PRESSURE: 50 + HP: WOODSTOVES: FURN < 100K BTU: AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: <= 10000 cfm: OTHER UNITS: > 10000 cfm: GAS OUTLETS: Owner: FEES WATUMULL PROPERTIES CORP Description Date Amount 307 LEWERS ST #6FLR [MECH] Permit Fee 4/29/200E $420.50 HONOLULU, HI 96815 [MECPLN] Plan Rev 4/29/200; $105.13 [TAX] 8% State Surchar€ 4/29/200: $33.64 Phone: Total $559.27 Contractor: CLIMATE CONTROL INC 16500 SW 72ND AVE REQUIRED ITEMS AND REPORTS PORTLAND, OR 97224 Phone: 503 453 - 4822 Reg #: LIC 62196 - This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain copies of these rules or direct questions to OUNC - calling 503 - 246 -6699 or 1- 800 - 332 -2344. ( % Issued By: :„i _� Permittee Signatur Call 503 - 639 -4175 by 7:00 a.m. for inspections that busine$ day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 7%Oo SW 71ch 0.-0 r Mechar. Permit Application FOR OFFICE USE ONLY , '' D i Received _ ��j City of Tigard WE Permit t `� ; (,,,Z ��1 j U © / 9,4 C � Date /By: _ - 13125 SW Hall Blvd., Tigard, OR 97 Plan Review y y ' Other Permit. Phone: 503.639.4171 Fax: 503.598 Date/By: � l :n Inspection Line: 503.639.4175 ■ �, j, e` I I Date ted/Meth !"^ ® See Page 2 for Internet: wtwv.ci.tigard.ocus Wit 2 2100 J Notified/Method: - j - ! (r Supplemental Information re ILg���Vp�ll COMMERCIAL FEE* SCHEDULE — USE CHECKLIST ❑ New construction �] All l�t�dlttTatio eplacement Mechanical permit fees* are based on the value of the work kt performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Other: mechanical materials. equipment. labor, overhead, and profit. CATEGORY OF CONSTRUCTION Value: S y , RESIDENTIAL EQUIPMENT) SYSTEMS FEES* ❑ I and 2 family dwelling ® Commercial /industrial ❑ Accessory building For special information use checklist. ❑ Multi family ❑ Master builder ❑ Other: Description I Qty. I Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling Job Air conditioning or heat pump ob site address: �]y 0 S S W _ e f k C e_nR 1 0 2 (requires site plan showing placement) 14.00 City /State /ZIP: r , a d 0 K q- a'a4 Furnace 100.000 BTU (ducts/vents) 14.00 • Furnace 100,000+ BTU ( ductslvents) 17.90 C Suite/bldg. /apt. no.: / ( Q Project name:; Q (Isles +e gn Gas heat pump • 14.00 C Cross street/directions to job site: Duct work 14.00 Hydronic hot water system 14.00 ...5‘. Residential boiler (radiator or hydronic) 14.00 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended. etc. 10.00 ;r6 Flue /vent for any of above 10.00 Subdivision: Lot no.: Other: 10.00 Tax map /parcel no.: Other fuel appliances DESCRIPTION OF WORK Water heater 10.00 T � f //' Gas fireplace 10.00 + "5 t � I i -J-h p. 9 e rA C Ir!, Ort e e.x - A t, S i- bi f) � m Ocj t Fv Flue vent for water heater or gas 4 C J fireplace 10.00 _Ski S-i-ems 1 in3i 3 duct St ins- And ?AS piee• Log lighter (gas) 10.00 Wood/pellet stove 10.00 Wood fireplace /insert 10.00 Chimney /liner /flue /vent 10.00 ❑ PROPERTY OWNER 14 TENANT Other: • 10.00 Name: TR A n s w Q, - P g n P U b I I S /1t Environmental exhaust and ventilation _ Range hood/other kitchen Address: 7905 S W I e( k e to +eQ �(C equipment 10.00 City /State /ZIP:' ' i 3 n Q d OR q-J a a y Clothes dryer exhaust 10.00 Single -duct exhaust (bathrooms, Phone: ( ) Fax: ( ) toilet compartments, utility rooms) 6.80 APPLICANT ❑ CONTACT PERSON Attic /crawlspace fans 10.00 Other: 10.00 Business name: C ti M A t C C 1120 Fuel piping Contact name: 0 el RIZQA Ustbon ' S5.40 for first four; $1.00 for each additional Furnace, etc. Address: I b 500 sti 7 a IA Avp Gas heat pump City/State /"ZIP: p o R I Prod 0 g, q 7 a� y Wall /suspended/unit heater Phone: (5 03) 953 , 4 8;a Fax: : ( So3i 9 6- 7 a 2 Y Fireplace ater , E -mail: Range CONTRACTOR Barbecue Business name: /� Clothes dryer (gas) 1, I I - n Te Con1 Po 1 Other: Address: 16500 3 w 72nd h Je MECHANICAL PERMIT FEES* City /State /ZIPp0 R f( r 0 R • gwD Subtotal Minimum permit fee ($72.50) Phone: (03) 4 53 . 4 $ g a Fax: (503) 1 q 6 8. 7 , y Plan review (25% of permit fee) CCB lic.: a I V State surcharge (8% of permit fee) TOTAL PERMIT FEE r _ ` I This permit application expires if a permit is not obtained �.itltin 180 da after it Authorized signature: V \ has been accepted as complete. Print name: ll • () g.-r Q 0 Date: kii u/ 0 • Fee methodology set by Tri- County Building Industry Service Board Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial Fee Schedule: . Total Valuation: Permit Fee: $1.00 to $2,000.00 Minimum fee $72.50 $2,001.00 to $5,000.00 $72.50 for the first $2,000.00 and $2.30 for each additional $100.00 or fraction thereof, to and including $5,000.00. $5,001.00 to $10,000.00 $141.50 for the first $5,000.00 and $1.80 for each additional $100.00 or fraction thereof, to and including $10,000.00. • $10,001.00 to $50,000.00 $231.50 for the first $10,000.00 and $1.35 for each additional $100.00 or fraction thereof, to and including $50,000.00. $50,001.00 to $100,000.00 $771.50 for the first $50,000.00 and • $1.25 for each additional $100.00 or fraction thereof, to and including $100,000.00. $ 100,000.01 and up $1,396.50 for the first $100,000.00 and $1.10 for each additional $100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. • • • • i:\BuildingWermits\MEC-PermitApp.doc I2/03 2 RECEIVED Form 4a APR 2 2 2005 Project Name:TgAnsWe3 -)-e(Ln Page: I SYSTEMS - GENERAL BUILDING DIVISJON Exceptions 1. Exceptions (Section 1313) Discussion of 01 No HVAC. The building plans do not call for an HVAC system. Skip to Item 12 below. qualifying excep- ❑ Exception. The building or part of the building qualifies for an exception from HVAC code lions on page 4-14 requirements. The applicable code exception is Section 1313, Exception . Portions of the building that qualify: See page 4-14 for a 2. Simple or Complex Systems (Section 1313.2 or 1313.3) discussion of simple l Simple System. The planned HVAC system qualifies as a Simple System. If true, complete this vs. complex form (4a) and equipment efficiency worksheets as required. Form 4b is not required. systems. ❑ Complex System. The planned HVAC system is a Complex System. Complete this form (4a), Form 4b and equipment efficiency worksheets as required. Exceptions 3. Economizer Cooling (Section 1313.1.2) Complex Systems ❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling. may claim the same Complies. The new fan system has an air economizer capable of modulating outside -air and exceptions allowed return -air dampers to provide up to 85 percent of the design supply air as outdoor air. for Simple Systems, plus three excep- ❑ Exception — Simple Systems. The new fan system qualifies for an exception. The applicable Lions allowed in code exception is Section 1313.1.2, Exception , or Section 1313.2.1. Portions of the Section 1313.1.2. building that qualify: See page 4 -15 for a discussion of these ❑ Exception — Complex Systems. The new fan system qualifies for an exception. The applicable exceptions. code exception is Section 1313.1.2, Exception , or 1313.3.1, Exception . Portions of the building that qualify: 4. Economizer Cooling — Overpressurizing (Section 1313.1.2) ❑ No Economizer. The building plans do not call for a new fan system with an economizer. ■ NI Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will exhaust the extra air introduced by the economizer, and the economizer system is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the load. 5. System and Zone Controls (Sec. 1313.1.3.1 8s 1313.1.3.2) IA Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zone. ❑ Exception. The new HVAC system qualifies for an exception from the zone control require - Exceptions ments. The applicable code exception is Section 1313.1.3.2, Exception 1 and 2. Portions of the Discussion of building that qualify: qualifying excep- tions on page 4 -16. 6. Control Capabilities (Sec. 1313.1.3.2.1) • Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1313.1.3.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section1313.1.3.2.1, Exception (10/98) Forms & Worksheets 4 -1 Form 4a (cont.) Project Name: TgAns w es 4-22r1 Page: A SYSTEMS - GENERAL 7. Off -hour Controls - HVAC Systems (Section 1313.1.3.3) F Complies. All new HVAC systems are capable of automatic setback or shutdown during periods of non -use or alternate use of the space served by the system. ❑ Exception. Equipment has full load heating demands of 2 kW (6,826 Btu /hr) or less and is controlled by a readily accessible manual off -hour control. 8. Off - hour Controls — Supply and Exhaust Systems (1313.1.3.3) • Complies. Plans require that outdoor air supply and exhaust systems have a means of auto- matic (either motorized or gravity damper) volume shutoff or reduction during periods of non -use or alternate use of the space served by the system. ❑ Exception. The building qualifies for an exception to the requirement for automatic shutoff or reduction. The applicable code exception is Section 1313.1.3.3, Exception 9. Heat Pump Controls (Section 1313.1.3.4) NI No Heat Pump. The plans /specs do not call for a new heat pump. ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled as required in Section 1313.1.3.4. 10. Equipment Performance (Section 1313.1.4) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment or heat - operated cooling equipment. • di Complies. All new HVAC equipment has efficiencies not less than those required by the code. The following equipment efficiency worksheets are attached: Un i 1- S e12c 11. Duct Insulation (Section 1313.2.2 as 1313.3.2) Li No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. E$ Simple System: Complies. The plans and specifications call for a Simple System, and all exterior supply /return air - handling ducts and plenums and all outside air ducts are insulated as required by Section 1313.2.2. Li Complex System: Complies. The building plans /specs call for a Complex System, and all air - handling ducts and plenums are insulated as required by Sec. 1313.3.2. 12. Piping Insulation (Section 1314) Exceptions l No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. Discussion of Li C lies. All new piping serving a heating or cooling system or part of a circulating service qualifying excep- P� P P 9 9 9 9 Y p 9 tions on page 4 -18 water heating system complies with the requirements of the Code, Section 1314.1. Li Exception. New piping qualifies for the following exception: Section 1314, Exception _ . 13. Service Water Heating (Section 1315) • 911. No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks, service hot water distribution systems, swimming pools or spas. Exceptions ❑ Complies. All new water heaters, hot water storage tanks, service hot water distribution sys- Discussion of tems, swimming pools or spas comply with the requirements of the Code. qualifying excep- Li Exception. The applicable code exception is Section , Exception . Portions tions on page 4 -18 of the building that qualify: • L J 4 - Forms & Worksheets (10/98) r - 2 Worksheet 4a Project Name:1 0 ns W P S 4- u fn Page: 3 UNITARY AIR CONDITIONER - AIR COOLED Equipment Cooling Proposed Proposed Seasonal or Part Discussion of Equip. Capacity Steady State Ref equipment ratings ID Model Designation (Btu/h) Efficiency (EER) Load Efficiency Line R and equi tq� � i R iti c Comf-o 2-J m A k.Q g. `f 5, 5 Do 10. D 3 APR 22 2005 RTU Comfo rz falh -v 55, 000 (0.0 3 CITY OF TIGARD RTU 7 COME o R+ m A keg 5 3 . 000 (0 .0 3 BUILDING DIVISION • Required Indicate source of information Documents- ARI Unitary Directory, Section AC, page: tion ARI Applied Products Directory, Section ULE, page: 7 Product data (Attach data furnished by the equipment supplier, i.e., "cut sheets ) l ohlighf or otherwise indicate equipment selected on documentation provided Co Cooling Capacity (Btu/h) Minimum Rating Required Equipment Type Ref. V Efficiencies Equal to or But less than Steady State Seasonal or Line Q greater than Part Load This schedule of Single Package 0 65,000 na 9.7 SEER = equipment efficiencies without a 65,000 135,000 10.3 EER 10.6 IPLV was reformatted from heating section 135,000 240,000 9.7 EER 9.9 IPLV (1) the code, Table 13 - G or with electric resistance heat 240,000 760,000 9.5 EER 9.7 IPLV 760,000 - 9.2 EER 9.4 IPLV Split System 0 65,000 na 10.0 SEER without a 65,000 135,000 10.3 EER 10.6 IPLV heating section 135,000 240,000 9.7EER 9.9 IPLV (2) or with electric 240,000 760,000 9.5 EER 9.7 IPLV , resistance heat 9.2 EER 9.41PLV 760,000 - Single Package 0 65,000 na 9.7 SEER with a heating 65,000 135,000 10.1 EER 10.4 IPLV section other 135,000 240,000 9.5 EER 9.7 IPLV (3) O R F. G C1 N than electric 240,000 760,000 9.3 EER 9.5 IPLV 2 �� resistance heat :> 760,000 - 9.0 EER 9.2 IPLV ' 0 65,000 na 10.0 SEER ✓'"::: >: >. Split Syystem 65,000 135,000 10.1 EER 10.4 IPLV ,3 with a heating € :: section other 135,000 240,000 9.5 EER 9.7 IPLV (4) < ''°>_o %f) :.K * ic 240,000 760,000 9.3 EER 9.5 IPLV ` "':'.. ".;.3 ::'::;: resistance than electr heat as.u.:.,.r.r.i.d.,.,,.t.i.ar 760,000 - 9.0 EER 9.2 IPLV E.ht..E..R, G..Y Condensing Unit FORMS Only 135,000 - 10.1 EER 11.2 IPLV (5) OCT 2000 4 - Forms & Worksheets (ioioo> Received Fax A.r 20 2005 3:38PM Fax Station : CLIMATE CONTROL INC . 23 04/20/2005 15:36 FAX 503 248 9263 VLMK ENGINEERS RECEIVED 2023/024 • APR 2 2 2005 'r_ • CITY OF TIGARD '` nmnmmmmmm....r.....,Co. mfo Coinf�r tinaker ci. 10 SEER, 3 -PHASE COMMERCIAL PACKAGE GAS ELECTRIC UNIT 3THRU5TONS UNIT SPECIFICATIONS Condenser Data , Electrical Data Coil Fan Motor . Fan HACR Total Face Tube Full • Size • No. • Voltage Breaker Area Fns Per Diamete • Load RPM Diameter Blades CFM Code Max fuse Array (Sq. Ft) In/iows (In.) HP CGP36H 208/230 -3 -60 30 amps. 20.0 14.9 20/1 3/8 1/3 1.9 1140 20.3 3 2 7 3000 .__) CGP48H • 208/230 -3 -60 35 amps, 22.9 10.5 20/2 3/8 1/3 1.9 1140 20.3 3 -27. 3000 -. CGP60H 208/230 -3 -60 45 amps. 30.9 14.9 20/2 3/8 1/3 1.9 1140 20.3 3 -27 3000 Evaporator Coil . Comjressor • Coil Motor Blower Total Face Tube Blower Fug Locked Factory Area Fins Per Dian H.PIType/ Load Rotor Type & RPM CFM Ro Load Lock Area Ch a rg f e Wt Ship Code (Sq. FL) In/Rows (In.) Speeds Amps Amps Size (Max) Rated Type Rotor Amps Amps F1•222 (oz) abs.) CGP36H 5.33 14/2 3/8 1 /2/PSC /3 4/1 7.50 DD11 -9A 1000 1250 RECIP 11.21 85 80 410 -� CGP48H 5.33 14/3 3/8 1 /2/PSC /3 4/1 7.50 DD11 -9A 1000 1600 RECIP 13.49 91 102 490 --- . CGP60H 5.33 14/4 3/8 1 /PSC /4 6.0 ,15.0 DD12 -12A 1000 1900 SCROLL 18.43 124 136 510 Finer are suppled with these units, 3 to 5 Ion use 14x25x1 (2) PERFORMANCE DATA: HEATING ) Input(MB1UH) Output(MBTUH) Efficiency Gas Transformer Code DOE (AFUE) Calif. (CSE) Temperature Piping Size Standard Standard Standard Std. Rise OF Size (IN.) Va. CGP36H100 100 80 80.0 76.0 35 1/2 65 --, CGP48H080 80 64 80,0 76.0 35 -65 1/2 65 _ CGP48H120 120 96 80.0 76.0 40 -70 1/2 --- CGP6OH100 100 80 80.0 76.0 25 -55 1/2 65 CGP6OH140 140 I 112 I 80.0 I 76 I 25-65 1/2 65 PERFORMANCE DATA: COOLING Rated Power Evaporator Ext. Static Capacity S/T Input Rated Pressure Drop' BTUH Ratio S.E.E.R. E.E.R. Watts Airflow (SCFM) Wet CGP36H100 • 38.000 .75 _ 10.0 • 8.7 4000 1250 .15 --. CGP48H080 45.500 .79 10.0 9.1 5115 1600 .15 ` CGP4BH120 , 45.500 .79 10.0 9.1 5115 X00 .15 .- CGP6OH100 58.000 ,75 • 10.0 8.8 6480 CGP6OH140 58.000 .75 10,0 8.8 6480 1900 .15 • BLOWER PERFORMANCE DATA •• A. d•I•rl•in.4 by 0.0 E. Annual Fuol Ui11.Nnn Air Delivery In CFM' • • Tee Matin e ap ay vela aa, Motor External Static Pressure (In. W.C. Z 0 .. .Pint. teal .b . Code Speed .20 .30 2.000 bet. ta .. ha* F.r :In d .I .Y. 36H80 .40 . 50 , 2.000 ea4.exy 4% lor CGP Mp 1770 1740 1670 •..n 1,000 I reduced .D ...a 1710 3611100 1385 1365 1355 cs Ax•ed.la nsalrrd.w _ LO !IRO _ 1170 1340 c s E. ab 1p. surm.a HI Il an tleD CGP 481-i0 M HI 1770 1740 1710 1670 I aloud Coma/ oAnl 1385 1365 1355 AM,. 80' 0 167 W se 1340 AM,. ea Dep61• We, at LO 1 183 1 170 1160 1 150 vah. Fa apple.Ih.n♦.I CGP 1810 Zoe w1. dower two ern 48H120 MD 1790 1780 1730 1403 2 Includes a w drop br ------.. LO 1230 1380 • l i oo0 (1 00 • le.r. • 1100 I CGP OH100 MD HI 2050 2030 2010 2000 MD LO 396o 1900 taw 1800 60H140 LO 1920 1840 1790 1720 1820 1760 1700 1620 Alr delivery apainel shown external stalk pressures taken with 230V to 2011 and dry coil Add .08 static for internal litters (Two 1402501) C -28 8/02 'ITY OF TIGARD UILDING DIVISION PERMIT #: 7:12AM MEC2005 -00192 3125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 4/29/2005 hone: (503) 639- 4171 "` i44 r�iI�h� Inspection Requests (24 Hrs.): (503) 639 -4175 _L! __ ' INSPECTION WORKSHEET FOR DATE: 5/25/2005 TIME: PAGE: 72 SITE ADDRESS: 07405 SW TECH CENTER DR 160 CLASS OF WORK: SUBDIVISION: SW COMMERCE CENTER LOT #: TYPE OF USE: PROJECT NAME: TRANSWESTERN PUBLISHING DESCRIPTION: Install (3) gas packs (3) duct systems,gas piping,exhaust fan,modify (4) duct systems. Valuation: $24,000. OWNER: WATUMULL PROPERTIES CORP, PHONE #: CONTRACTOR: CLIMATE CONTROL INC PHONE #: 503- 453 -4622 Inspection Request Scheduled For: Date: 5/25/2005 Pour Time: • Code # Inspection Description Confirm # Contact # Message 699 Mechanical final 007639-01 503. 453 -4822 N Corrections /Comments /Instructions: 1 „- 1 _. • 1 K4 If''r 11 [iir PASS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITI AL F ES ASSESSED Inspector: Date: Z ' Phone #: (503) 718-