Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
MOW MASKER i TV ®F TIGARD DATE I ISSUED: 06; X596 k ��� 7i_ COMMUNITY DEVELOPMENT DEPARTMENT 13125 SW Hall Blvd. Tigard, Oregon 97223.8199 (503) 639 -4171 PARCEL: 1 S 125DA -11400 SITE ADDRESS...: 06500 SW TAYLORS FERRY RD SUBDIVISION....: 1996 -005 ZONING: R -4.5 BLOCK.....„..... LOT • Remarks: PATH I -- -- BUILDING REISSUE: STORIES • 2 FLOOR AREAS BASEMENT...: 0 sf REQUIRED SETBACKS - - -- REQUIRED CLASS OF WORK.:NEW HEIGHT • 28 FIRST • 1008 sf GARAGE • 440 sf LEFT • 15 SMOKE DETECTRS: Y TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 1018 sf FRONT • 35 PARKING SPACES: 1 TYPE OF CONST.:5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 5 OCCUPANCY GRP.:R3 BDRM: 3 BATH: 3 TOTAL - - - -: 2026 sf VALUE..$: 138525 REAR : 30 - ---- - PLUMBING --- SINKS • 2 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 1 RAIN DRAIN ft: 0 TRAPS • 0 LAVATORIES • 5 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 1 CATCH BASINS..: 0 TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0 OTHER FIXTURES: 0 — ---------- - - - --- ---- - ----- MECHANICAL - ---- - ---------------------------- FUEL TYPES FURN (100K ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1 /GAS/ / / FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES • 0 GAS OUTLETS...: 1 ELECTRICAL -- - - - - -- - -- RESIDENTIAL UNIT - -- -- SERVICE /FEEDER - - -- - -TEMP SRVC /FEEDERS -- -- BRANCH CIRCUITS - -- - - -- MISCELLANEOUS - - -- - -ADD'L INSPECTIONS- - 1000 SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 3 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: @ PER HOUR • 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF HM /SVC /FDR: 0 601 - 1000 amp.: 0 601 +amps -1000 v: 0 MINOR LABEL -10: 0 1000+ amp /volt.: 0 PLAN REVIEW SECTION - Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC: - -- — ----- - - - - -- ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL --- B. COMMERCIAL AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: OTH: :: X BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: HVAC • DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0 Owner: ---- - - - - -- Contractor: - - TOTAL FEES:$ 4458.46 NDC LTD. NDC LTD P 0 BOX 1985 PO BOX 1985 LAKE OSWEGO OR 97035 LAKE OSWEGO OR 97035 Phone #: 697 -3801 Phone #: 697 -3801 Reg #..: 099813 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. --- _— -------- - - - - -- REQUIRED INSPECTIONS --- --- - -- Footing Insp PLM /Underfloor Shear Wall Insp Insulation Insp Appr /Sdwlk Insp Erosion Control Foundation Insp Mechanical Insp Low Voltage Gyp Board Insp Electrical Final Post /Beam Struct Plumb Top Out Fireplace Insp Rain drain Insp Mechanical Final Post /Beam Mechan Electrical Servi Gas Line Insp Water Line Insp Plumb Final Crawl Drain Framing Insp Gas Fireplace Water Service In Building Final • Perm ittee Signature: .10C ,.(/ Issued By: •. ., I. „urIA54e2 Call for inspection — 639-4175 Residential Building Permit Application City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 (503) 639 -4171 675 )AkCes -� � `Af. 61, Jobsite Address: b SW Taylors Ferry Rd., Tigard Subdivision: P.P. 1996 -005 Lot # 1 Office Use Only Valuation: $138;525 Contact Date 5 /30/ 46 Initials - C Result R• C hct , (er _ New Construction Only: (Square Footage) Planck/Rec # 5 — House: 2026 Garage: 440 Permit # en 5 i' y - U 2 7 2 - - Reissue of Corner Lot? Y N Flag Lot? Y N Map & TL # /5/ S . ' I I 'Ic' 7 Zone K- LI is Owner: NDC Ltd. Plat # l9/// Address: P.O. Box 1985 Approvals Required Lake Oswego, OR 97035 Pla nning Setbacks Solar � � ixfi' Engineering f`r �4 -v +b raeA Phone: ( 503 697 3801 Other Contractor: NDC Ltd. 13- Q_c Items Required Address: P.O. Box 1985 Subcontractors Truss Details Lake Oswego, OR 97035 Other Q Phone: ( 503 697 3801 Notes MLI Contractor's License # 99813 `h 1 FUe ni't Of-5k 1) 2.'1 (attach copy of current Oregon license) t Contact Name: Charles Duck Contact Phone: ( 503 1 697 3801 Subcontractors: Architect/Engineer: Plumbina: Re.c460�n't Li/r)b ,, y Address: v Mechanical: g ;: / ' , ‘e S 1-le4oN, (attach copy of current OR Contractor's License) Electrical: ye, Phone: ( JOB DESCRIPTION: ( 1 Applicant Signattyie Applicant Phone number • Received by:` friAlAe Date Received: 3 ZI (�o . h- ne;imcss r�saoo li f • w Permit 4 Account Description Amount Amt. Pd. Bal. Due //./ 7Z- Bldg. Permit (BUILD) ,53v f .SU ( 45 a ,`j �s Plumb. Permit (PLUMB) 2 2 ciU 2 5 . Mech. Permit (MECH) cam' , �. gic Bldg: Ca S 3 S i. Z r .% Plumb: //. Z Mech: P • L _ / //4 Z. > Plan Check (PLANCK) 3 U. r3 z5 9q Y� Bldg: 3 e/`/. Plumb: Mech: //r 2 / Z > A/4.4 0 Sr Sewer Connection (SWUSA) 0.7?e, • ZUt/ • Sewer Inspection (SWINSP) g 3 ,` Parks Dev Charge (PKSDC) /OS 56 Residential TIF (TIF -R) // ,/1 Mass Transit TIF (TIF -MT) l Z G /?-j Commercial TIF (TIF -C) Industrial TIF (TIF -I) Institutional TIF (TIF -IS) Office TIF (TIF -0) Water Quality (WQUAL) Water Quantity (WQUANT) / U Fire Life Safety (FLS) Erosion Cntrl Permit (ERPRMT) (( Erosion Planck/USA (ERPLAN) "4 ✓ "- Erosion Planck/COT (EROSN) - ,,hi d‘ C TOTALS: 64A__4_(ezg() %° �B Page No. 1 CASE HISTORY FOR CASE NO.: MST96 -0272 NDC LTD. 06500 SW TAYLORS FERRY RD 12/02/98 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By - - - - - -- -- - -- - - -- - -- - - -- MSTA005 Application received / / / / 05/21/96 PASS BON 05/29/96 BT2 MSTA008 Permit Created / / / / 05/29/96 PASS RT 05/29/96 BT2 MSTA010' Check for prcl. restrict. / / / / 05/24/96 PASS BON 05/29/96 BT2 MSTA012 Plans routed to Plans Examiner / / / / 05/24/96 PASS BON 05/29/96 BT2 MSTA026 Plans approved by Plans Exmr / / / / 05/29/96 PASS RT 05/29/96 BT2 MSTA030 Reviewed plans routed to DSTS / / / / 05/29/96 PASS RT 05/29/96 BT2 • MSTA080 (F) Ready to issue / / / / 05/30/96 PASS CJS 05/30/96 CJS MSTA092 (F) Issue combination permit / / / / 06/20/96 PAID JMH 06/20/96 J *H MSTA097 Issue plumbing signature form / / / / 06/20/96 PAID JMH 06/20/96 J *H MSTA098 Issue electric signature form / / / / 06/20/96 PAID JMH 06/20/96 J *H MSTA098 Issue electric signature form / / / / 08/16/96 PASS CJS 08/16/96 CJS MSTA705 Footing Insp / / / / 07/26/96 APP KS 07/29/96 KBS MSTA706 Foundation Insp / / / / 07/26/96 APP KS 07/29/96 KBS . ATA7l0 Post /Beam Structural / / / / 08/02/96 APP KS 08/03/96 KBS MSTA711 Post /Beam Mechanical / / / / 08/02/96 8 -1- support furnace plenum at crawl A/N KS 08/03/96 KBS # -2- increase dryer vent to five inch diameter MSTA713 Crawl Drain / / / / 09/18/98 PASS RC 09/20/98 J *H MSTA717 PLM /Underfloor / / / / 08/02/96 PASS MS 08/05/96 MRS MSTA720 Mechanical Insp / / / / 09/13/96 APP KS 09/13/96 KBS MSTA722 Plumb Top Out / / / / 09/09/96 require fixture fitting PASS MS 09/09/96 MRS MSTA723 Electrical Service / / / / 09/13/96 PASS TLP 10/14/96 TLP MSTA725 Framing Insp / / / / 09/11/96 4-1- fireblock soffits at agarage DIS KS 09/11/96 KBS mechanical chase 8 -2- positive connection trimmers to garage header # -3- need clearance at B vent garage 8 -4- strap 4/4 post to header /entry 8 -5- fireblock stair jacks 8 -6- connect exhaust fans # -7- nail each side of double ridge rafter 9 -7- secure protective collar at B vent attic 8-8- block splice above header rear bedroom MSTA725 Framing Insp / / / / 09/13/96 8-1- General contractor, will change A/N KS 09/13/96 KBS glazing adjacent to rear man prior to final inspection MSTA726 Shear Wall Insp / / / / 08/30/96 N/R KS 09/03/96 KBS MSTA726 Shear Wall Insp. / / / / 09/03/96 APP KS 09/06/96 KBS Page No. 2 CASE HISTORY FOR CASE NO.: MST96 -0272 NDC LTD. 06500 SW TAYLORS FERRY RD 12/02/98 Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MSTA735 Gas Line Insp / / / / 09/11/96 # -1- 25 PSI for 15 minutes APP KS 09/11/96 KBS MSTA740 Insulation Insp / / / / 09/13/96 APP KS 09/13/96 KBS MSTA745 Gyp Board Insp / / / / 09/24/96 # -1- ok to mud /tape interior. gypsum at PART KS 09/24/96 KBS garage not hun MSTA755 Rain drain Insp / / / / 07/30/96 PASS MS 07/31/96 MRS MSTA760 Water Line Insp / / / / / / TV 09/20/98 J *H MSTA765 Appr /Sdwlk Insp / / / / 09/18/98 Private Street. PASS PI 09/20/98 J *H Original approach from demo'd house used. MSTA770 Misc. Inspection / / / / 09/17/96 #1 -1- slab on grade / garage fl APP KS 09/17/96 KBS MS TA790 Electrical Final / / / / 06/19/97 PASS BRP 06/19/97 J *H MSTA795 Mechanical Final / / / / 06/19/97 PASS RC 06/19/97 J *H MSTA797 Plumb Final / / / / 06/19/97 Replace tub overflow cover at clothes PASS RAH 06/20/97 J *H washer with proper access cover. MSTA799 Building Final / / / / 06/19/97 Handrail exceeds 2 5/8" diam. outside FAIL RC 06/19/97 J *H porch. MSTA799 Building Final / / / / 09/18/98 PASS RC 09/18/98 ROC MSTA960 (F) Issue Cert. of Occupancy / / / / 09/18/98 12/02/98 JT MSTB708 Erosion Control / / / / / / 05/29/96 BT2 CITY OF TIGARD BUILDING INSPECTION DIVISION MST 9 '`c.73-- 24 -Hour Inspection Line: 639 -4175 Business Line: 639 - 4171 BUP �+ t 7 Date Requested q` / I - f �" (; AM PM BLD Location ? 5I l � �•W- Suite MEG Contact Person (es_ Ph 4 b 1 PLM Co _ - Z .. 1 ' /' Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Foundation Access: himdmiti Q��L AL C C ((glgi FPS Ftg Drain SGN Crawl Drain Inspection Notes: y,� 0 c „„_ 1, . A Slab !� cu V SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing _ Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof F*- t' PART F • IL •' BIN - "' . Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL t Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL OP Service Rough In UG /Slab Low Voltage Fire Alarm Final • PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA �� proach /Si ewa p� ¢� of er Date _ l - f v - 67 1 Insp ec t or E x t Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.