Loading...
Permit A :10 CITY OF TIGARD DEVELOPMENT SERVICES MASTER PERMIT PERMIT #- - ... - .: MST96 -0311 � °__:. 13125 SW HaII Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 11 /15/96 1. PARCEL: 19133CC —PB343 SITE ADDRESS...: 11541 SW TALLWOOD DR SUBDIVISION • PEBBLECREEK #3, . ZONING: R -25 BLOCK ..... ..o... LOT........... a. :43 Remarks: PATH I ------------- --- - -- -- - - - - -- BUILDING -------------------- REISSUE:MST96 -0254 STORIES : 2 FLOOR AREAS- BASEMENT...: 0 sf REQUIRED SETBACKS - - -- REQUIRED - - - -- CLASS OF WORK.:NEW HEIGHT • 26 , FIRST..... 949 s.f. GARAGE...:..:... 520 sf LEFT • 5 SMOKE DETECTRS: Y TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 883 sf FRONT : 20 PARKING SPACES: 1 TYPE OF CONST.:SN DWELLING. UNITS: 1 FINBSMEENT:. .0 sf RIGHT •. 5 OCCUPANCY GRP.:R3 BDRM: 3 BATH: 3 TOTAL -: 1832 sf VALUE..$: 127349 REAR • 15 -- ____ - - -_ -- _ —_ -- -_ PLUMBING '- - - ---- SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS • 0 ' LAVATORIES • 5 DISHWASHERS.: 1 FLOOR 'DRAINS..: 0 SEWER LINE ft: 0 -SF RAIN DRAINS: 1 '- CATCH BASINS..: 0 TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0 OTHER FIXTURES: 0 - - - -_— — _-------- ____------- - - ---- MECHANICAL - - - -- -------- - - - - -- FUEL TYPES FURN (100K ..: 1 BOIL /CMP ( 3HP: 0 VENT FANS - 4 CLOTHES DRYERS: 1 /GAS/ / / FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS - 1 OTHER UNITS...: 1 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS : 0 ' WOODSTOVES....: 0 GAS OUTLETS...: 1 ---------------------- _-- _____ -- -- ELECTRICAL -- - - - - -- -- RESIDENTIAL UNIT — — SERVICE /FEEDER -- —TEMP SRVC /FEEDERS -- ' -- BRANCH CIRCUITS - -- -- -- MISCELLANEOUS -- - -ADM INSPECTIONS-- 1m SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 3 201 - 400 amp..: 0 201 - 400 amp..: 0 . 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0. PER HOUR......: 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF HM /SVC /FDR: 0- 601 - 1000 amp.: 0' GOD-amps-1000 v: 0, . . . MINOR LABEL -10:' 0 1000+ amp /volt.: 0 -------------------- - - - - -- PLAN REVIEW SECTION ---- --- -- --- --- --_ ---- --- —_— Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) =225 A.: ) 6 ;'' V NOMINAL: CLS AREA /SPC OCC: ------------- - - - - -- - -- ELECTRICAL - RESTRICTED ENERGY -------------- ------ --- - -- -- A. SF RESIDENTIAL --- - - - - -- B. COMMERCIAL - - - - -- - -- -- -- -- AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM - INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: OTH: :: X BOILER • HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: .• HVAC DATA /TELE COMM.: NURSE CALLS TOTAL # SYSTEMS: 0 Owner: --- __________ ___-- _ —__— --- -Contractor: -- --- - - - - -- TOTAL FEES:$ 4117.06 COSTA PACIFIC HOMES COSTA- PACIFIC HOMES 8625 SW CASCADE BLVD #606 8625.SW CASCADE AVE STE.606 . BEAVERTON OR 97005 BEAVERTON OR 97005 Phone #: 646 -8888 Phone #: 503 -646 -8888 Reg #..: 65157 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days.. ------- ------ - - - - -- REQUIRED INSPECTIONS -- --- -- --- ---- --- _ --- --- ------ — --- _ ------ __ -- --- ---- —_ Footing Insp PLM/Underfloor Framing Insp Gas Fireplace Water Service In Building Final Foundation Insp Mechanical Insp Shear Wall Insp Insulation Insp Appr /Sdwlk Insp Erosion Control Post /Beam Struct ' Plumb Top Out Low Voltage Gyp Beard Insp Electrical Final Post /Beam Meehan Electrical Servi Fireplace Insp Rain drain Insp Mechanical Final Crawl Drain Electrical Roug / Gas Line Insp • Water Line Insp Plumb i -1 Per ^mittee Signati_ir ^e: ► © �1 _ / ss�_Led y: /. 111, Call f o inspect — 639 -4175 Tv 006 (0 - I LI -(p • Residential Building Permit Application City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 (503) 639 -4171 Jobsite Address: 11541 SW Tallwood Drive Subdivision: Pebble Creek 3 Lot# 43 Valuation: /P- 7 3 New C onst c i ru ton0 Only: (Square uar eF Footage) e ancW ec House: 1823 sf 520 sf3.1 /:;:;:;':<' ° ": Garage: s Reissue of: MT'.er - ' ::6'b Flag Corner Lot? Y N Fla Lot? Y N . . f: Ct✓. -.: : .. Owner: Costa Pacific Homes Address: 8625 SW Cascade Ave . , Ste 606 - pprovals Re �`uir to Beaverton, OR 97005 ;Planning` "Setbacks::.;` Engineering;:E Phone: t 503 ) 646 -8888 .,. r° ems Contractor: SAME ubcontractors Address: � 'Phone: ( ) es .: .:.....dt= :. -..r Contractor's Li 65157 License # (attach copy of o current t Or e on license) e ( li p Y 9 Contact Name: Barbara L. Biron Contact Phone: ( 503 ) 646 -8888 Subcontractors: Architect/Engineer: Tvarson Associates, Inc. Plumbing: Wolcott Plumbing Address: 151 Ka 1 mias Drive, Suite C -140 Mechanical: Arco Installations, LTD Costa MPSa, CA 92626 (attach copy of current OR Contractor's License) Electrical: Bear Electric Phone: ( 714 ) 549 -3479 • JO DESCRIPTION: / I ' f / -0 ",///(i , "://4-91 ) ( f ?? `pplicant Signature Applicant Phone number Received by: 111 Date Received: b60 H , bpctldstslresapp ._ 1,1 Permit $ Account Description Amount Amt Pd. Bad. Due /h57 f( -U3// Bldg. Permit (BUILD) Spa so3 Plumb. Permit (PLUMB) 0.2.-2._( .22) Mech. Permit (MECH) 43 . ,v 4/3 ,) s-2 _X83' Sta Tax (TAX) a.5.&,, / ft3^ P.S.°O Bldg: 5 ./) 49' IOr4 . Plumb: // -2. Mech: 0 ,/ S 't- C. //, L� Plan Check (PLANCK) ,rP 50 ° -"- Bldg: S D Plumb: Mech: /U.9 6 /U $,i / : --- - SGuRQ6 -O y' Sewer Connection (SWUSA) a..2U u aJ tU Sewer Inspection (SWINSP) 3 S - - 3: - Parks Dev Charge (PKSDC) /0_57) /ds 0 Residential T1F MF -R) / C/ 7 /470 U (°° . Mass Transit TIF (TIF -MT) ., / 24 / r' d Commercial TIF (TIF -C) Industrial T1F (TTF -1) Institutional T1F (TIF -1S) Office TIF (T1F -C) Water Quality (WQUAL) /F1/ /80 Water Quantity (WQUANT) it/U /0 0 Fire Life Safety (FLS) Erosion Cntri Permit (ERPRMT) C 6 Cl' Erosion Planck/USA (ERPLAN) ?0f• P cp, N Erosion Planck/COT (EROSN) Ali.,F c 20. ea 0/' G TOTALS: _�l0 7 r �I _ ()� ___0CJ \ . %-7 -1036 Solar Balance Point Standard Worksheet i Address 115'41 SW ltio r Box A calculations: North -South dimension for the lot. Box A: This dimension is determined by finding the midpoint of the North lot line and drawing an intersecting line perpendicular to that point. First, determine which property line is the North lot line. The North lot line is the line with the smallest angle from a line drawn east -west and intersecting the northern most point of the lot. ®. 45 . NOR RN CPIHERN LOT UNE LOT UNE N North -South Dimension for Lot: Measure the distance from the midpoint of the North lot line to the South lot line along the described line. �/ 7 feet t N , T s .• NCR7H -SOUTH DIMENSION L..-- , >. : Box B calculations: Shade point height for your residence. Box B: 1. Determine whether measurements will be based on the peak or eave of your Which describes structure. The orientation of the ridge is also important. your residence? 1 a: If the roof line runs North - South, measurements will i � \-N' (circle one) be based on the peak of the roof. 00 E f1IJ ^IIII NORM .--IS 1A 1 B d 0 1 b: If the roof line runs East -West and the roof pitch is less than 5/12, measurements will be based on the 5 a =ow nx, eave. SNTCE ?C .NT _A'..E 1c: If the roof line runs East -West and the roof pitch is 5/12 or steeper, measurements will be based on the ; ., 12 /cot •c• pa n.p peak. SCE X;NT <D�E Box B. continued Box B: 2. Measure change in elevation from front property line to finished floor elevation. If the lot slopes up from the front lot line to the foundation, the figure is positive. If the lot slopes down from the front lot line to the foundation, the figure is negative. 3. Measure distance from finished floor elevation to the affected peak/eave. 1 Z ft 4. If the roof line runs North - South, deduct three feet. If the roof line runs East -West, - (2 ft deduct nothing. 5. Subtract one foot for each foot of difference in elevation from the front property line to the rear property line, if the lot slopes up from the front to the rear. If the lot has no slope or slopes up from the rear to the front, deduct nothing. - 7) ft 6. Total figure for box B: Z ft Box C. Distance to the shade reduction line. Box C: 1. Measure the distance from the North property line to the foundation near the ?i ft affected peak/eave. 2. Measure the distance from the foundation to the affected peak or eave. ± 1 . 5.5 ft 3. Total figure for box C: $55 C ft It is most useful to draw a vertical line to represent the appropriate figure found in box "A" and a horizontal line to represent the appropriate figure found in box "C ". The intersection of the vertical and horizontal lines determines the value found in box "D ". The value in box "D" should be compared to the value in box "8 "; if the value in box "B" is less than or equal to the value found in box "D ", then the building is in compliance with the solar balance code. If you have any questions, please contact us at 639 -4171, x304 or at the Community Development Counter. MAXIMUM PERMITTED SHADE POINT HEIGHT (In Feet) E Distance to North -south lot dimension (in feet) shade 100+ 95 90 85 80 75 70 65 60 55 50 45 40 reduction line from northern lot line (in rPet) 7 0 40 40 40 41 42 43 44 65 38 33 38 39 40 41 42 43 60 36 36 36 37 33 39 40 41 42 55 34 34 34 35 36 37 33 39 40 41 50 32 32 32 33 34 35 36 37 38 39 40 45 30 30 30 31 32 33 34 35 36 37 33 39 40 23 28 23 29 30 31 32 33 34 35 36 37 38 35 26 2 6 2"6 2 ; 23 29 - 30 31 32 33 34 35 36 30 2 24 24 25 26 27 28 29 30 31 32 33 34 25 22 22 22 23 24 23 26 27 23 29 30 31 32 20 20 20 20 21 22 23 24 25 26 27 28 29 30 15 13 18 18 19 2 0 21 22 2 3 24 25 26 27 2 3 10 16 16 16 17 18 19 20 21 22 23 24 25 26 5 14 14 14 15 16 17 18 19 20 21 22 23 2 4 Box D. Maximum allowed shade point height: ` I 7i1 feet 5/9/99 Activities for Case #: MST96 -00311 8:43:59 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA005 Application received 6/7/96 JH PASS BT2 6/17/96 MSTA008 Permit Created 6/17/96 RT PASS BT2 6/17/96 MSTA010 Check for prcl. restrict. 6/14/96 BON PASS BT2 6/17/96 MSTA012 Plans routed to Plans Examiner 6/14/96 BON PASS BT2 6/17/96 MSTA026 Plans approved by Plans Exmr 6/17/96 RT PASS BT2 6/17/96 MSTA030 Reviewed plans routed to DSTS 6/17/96 RT PASS BT2 6/17/96 MSTA705 Footing Insp 11/26/96 RB PASS RB 11/26/96 pending- continuous footing at garage; seismic restraint; ufer tagged usa 11 -25 MSTA706 Foundation Insp 12/3/96 KS APP KBS 12/3/96 MSTA713 Crawl Drain BT2 6/17/96 MSTA71 PLM /Underfloor 12/19/96 MS PASS MRS 12/20/96 MSTA720 Mechanical Insp 2/19/97 RB FAIL RB 2/19/97 see framing this date MSTA722 Plumb Top Out 2/12/97 MS PASS MRS 2/13/97 MSTA723 Electrical Service 2/19/97 GS APP GES 2/19/97 MSTA725 Framing Insp 2/19/97 RB FAIL RB 2/19/97 gas test; soffit duct in garage; remove exhaust fan out of return air & block floor space; • exhaust fan disconnected; B -vent surround; close off chase upstairs; b -vent clearance w /in chase; firestop floor and lid of chase; metal plate protection; chase exhaust vent w /in closet S. bedrm; close off gaps at bird - blocking; ventilate vaulted rafters at master bedrm and living rm; seal joints of heat duct; strap plates; support 4X header in famrm; re- support notched floor joist in famrm; add bearing rear side wall of garage /famrm; provide header at kitchen; add nailing to hangers at famrm & garage truss clip; 4x supporting floor (base of stairs) need to be 2 or better; close off unusable space at kitchen entry; nail plate electrical service; SHEAR `77 MSTA726 Shear Wall Insp 2/18/97 RB FAIL RB 2/18/97 not ready Page 1 of 3 5/9/99 Activities for Case #: MST96 -00311 8:43:59 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA727 Low Voltage BT2 6/17/96 MSTA735 Gas Line Insp , 2/19/97 RB FAIL RB 2/19/97 gas pressure dropped; MSTA745 Gyp Board Insp 3/10/97 KS A/N KBS 3/10/97 #-1- seal voids at return air supply duct with gypsum or twenty gauge sheet metal #-2- seal void behind furnace / metal or gypsum # -3- secure insulation adjacent to B vent will recheck at final MSTA755 Rain drain Insp 1/8/97 MS PART MRS 1/8/97 no crawl drain needs to be pumped MSTA760 Water Line Insp 1/8/97 MS PASS MRS 1/8/97 MSTA765 Appr /Sdwlk Insp 3/25/97 PI PASS KAS 4/4/97 OK MSTA790 Electrical Final 4/28/97 TLP PASS TLP 4/30/97 MSTA795 Mechanical Final 4/30/97 RB FAIL RB 4/30/97 SEE BUILDING FINAL,THIS DATE MSTA797 Plumb Final 4/24/97 MS PASS MRS 4/25/97 MSTA799 Building Final 4/30/97 RB FAIL TLP 5/1/97 NO UNDER -FLOOR INSULATION; VEHICLE BARRIER; FIRESTOP THRU PENETRATIONS AT FURNACE; UNDER- FLOOR- INSULATE WYES REPAIRS TEARS IN FLEX SUPPORT FLEX AT 4' INTERVALS /4" OFF GROUND REMOVE WOOD DEBRIS TERMINATE DUCT TO FLOOR LEVEL CLEAR LOW POINT DRAIN MSTB708 Erosion Control 4/25/97 USA PASS RB 4/30/97 • MSTA724 Electrical Rough In 2/19/97 GS APP GES 2/19/97 fan box in Ir /din rm MSTA080 (F) Ready to issue 6/18/96 CJS PASS CJS 6/18/96 MSTA092 (F) Issue combination permit 11/15/96 DRA PASS DRA 11/15/96 MSTA097 Issue plumbing signature form 12/2/96 DRA OK KAS 12/2/96 MSTA098 Issue electric signature form 12/2/96 DRA OK KAS 12/2/96 MSTA710 Post/Beam Structural 12/19/96 RB FAIL RB 12/19/96 plumbing failed; post address; support cross girders w /hangers; anchor bolts missed at ends on north wall; nail plate plumbing along west wall; 2x6 joists missed 2- locations; pier missed w/o posting between 3 & 4 girder row. Page 2 of 3 5/9/99 Activities for Case #: MST96 -00311 8:43:59 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA711 Post/Beam Mechanical 12/19/96 RB PASS RB 12/19/96 MSTA710 Post/Beam Structural 12/24/96 RB PASS RB 12/24/96 PENDING- CHECK FOR PLUMBING CORRECTIONS; ADD 2- ANCHOR BOLTS ON N. WALL; POST CROSS . GIRDER -WHERE MISSED. MSTA735 Gas Line Insp 2/20/97 RB PASS RB 2/20/97 MSTA726 Shear Wall Insp 2/20/97 RB PASS RB 2/20/97 MSTA720 Mechanical Insp 3/5/97 RB PASS RB 3/5/97 pending- seal joint of heat duct in fam rm MSTA725 Framing Insp 3/5/97 RB PASS RB 3/5/97 pending mech issue MSTA740 Insulation Insp 3/5/97 RB PASS RB 3/5/97 once framing /mech issues resolved. MSTA765 Appr /Sdwlk Insp 4/4/97 4/1/97 PI PASS KAS 4/4/97 1. COMPACT SUB -ROCK. MSTA799 Building Final 10/16/98 RB FAIL RB 10/16/98 RESEARCH- 1058 am Received FAX from David Mullens; Costa Pacific Homes re: Final Approval submitted for verification of Permit Case finaling. David Mullens submitted only page 3 of 3, which was given to the builder, as to allow for financing, as the buyer needed this assistance. Page 1 of 3 and page 2 of 3 have not been dealt with. NOTE: Granted home owner 10 days to comply with this inspection notice AND IF NOT COMPLETED BY THIS TIME, A $30.00 RE- INSPECTION FEE SHALL BE ASSESSED EACH DAY THEREAFTER. I ASKED FOR A RETURN CALL IMMEDIATELY. MSTA795 Mechanical Final 10/16/98 RB FAIL RB 10/16/98 See Building Final this date. MSTA795 Mechanical Final 2/19/99 RB PASS RB 2/19/99 MSTA799 Building Final 2/19/99 RB PASS RB 2/19/99 Case Final . MSTA960 (F) Issue Cert. of Occupancy 2/19/99 MAIL VIV 2/26/99 Mailed 2/26/99 Page 3 of 3 CITY OF TIGARD BUILDING INSPECTION DIVISIO S T — 3/ j 24 -Hour Inspection Line: 639 -4175 Busin-ss L i' :639 1 MUP W -Q-CylkalLpite 2 -CVC\� - PM LD Requested BLD Location I t S 4 S W rdU (.,6 Suite MEC Contact Person Ph PLM Contra • r Ph SWR :' Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Slab Inspection Notes _ Q (� �`( v` ` � � SIT Post & Beam Ext Sheath /Shear Ina Sheath /Shear , - � Al / / 6 Ct Framing Insulation IMW 1 / - Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Mis • PART FAIL ° ' BING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS °: T FAIL ost :: eam Rough In Gas Line Smoke Dampers °A' PART FAIL TRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Otheoach /Sidewalk Date �� "l 1 Inspector Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.