April 19, 1996
CITY OF TIGARD
OR EGON
MCM Architects
1022 SW Salmon #350
Portland, OR 97205
jCko ( � C - -� y o�, lv c�ti � � C�
Re: "SITE"
East of 135th Avenue
PC2 -113C SIT 96 -0013
The plans and specifications have been reviewed for conformity to
applicable codes. Please submit three (3) sets of revised plans
and specifications incorporating the following requirements:
Site
What is the total cubic yardage of site excavation? 6/
What is the total cubic yardage of engineered fill? $» O0
Grading in excess of 5,000 cubic yards shall be designated
engineered 'grading [OSSC, Section 7006 (c) (d) ] .
✓�- Submit a soil engineering report.
-B Submit an engineering geology report.
1 r Inspection form and return to
Complete the enclosed Special Ins
� P P P
this office prior to our issuance of the building permit.
Ai." Copies of all special inspection reports shall be filed with
7 this office continually during construction. A final signed
report must be on file before occupancy will be permitted
[OSSC, Section 306(c)].
4P . Provide the total square footage of impervious area of the
buildings, streets, parking lots, and sidewalks. J.-d.; 71-t
, .
Submit the cost breakdown for each category of site
. preparation including, but not limited to, those listed below:
A. Site preparation.
B. Grubbing and grading.
C. Utilities.
D. Storm, sanitary, fire hydrants, fire sprinkler, and
domestic water piping.
E. Paving.
F. Curbs and sidewalks.
G. Erosion control. a
H. Retaining walls and railing.
3125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
MCM Architects
April 19, 1996
pg. 2
I. Landscaping.
J. Lighting.
4 K. Accessibility requirements.
The wood barricade specified at the emergency fire apparatus
access from 133rd Avenue is not permitted by the Tualatin
Valley Fire and Rescue. Contact Gene Burchill at 526 -2602.
Fill placed on property which is to support the foundation of
any building shall be placed in accordance with accepted
engineering practice. Submit a soils investigation report and
a report from an approved testing agency of satisfactory
placement of fill [Section 2903] .
If you wish to discuss any of these items, please give me a call.
Sincerely,
d ,,„e! / .
James Funk
Plans Examiner
Enclosure .
eit96- 0013\pc2 -113c