Correspondence City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 March 4, 2007 • N Jason Hering Costruction PO Box 700 T I GARD Banks, OR 97106 RE: Single family residence addition Project Information Building Permit: MST2007 -00026 Construction Type: VN Address: 12211 SW Sweeney Pl. Occupancy Type: R -3 Area: 348 Sq. Ft. Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; the State of Oregon Oregon Residential Specialty Code ORSC) 2005 edition and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans have been reviewed and the following information is required prior to issuance of the permit. 1) Foundation at rear of garage was made for a single story and might be only 12 in. wide whereas your footing with the addition would have to be 15 in. wide. 2) Truss plans are not showing the girder truss to carry the existing truss load. 3) Not showing the direction of the existing floor joist as to where they bear. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson • Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772