Loading...
Permit MASTER PERMIT CITY OF TIGARD PERMIT #: MST1999 -00347 �m ell DEVELOPMENT SERVICES DATE ISSUED: 10/26/1999 , 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 SITE ADDRESS: 11455 SW SHROPE CT PARCEL: 2S103AB -WG006 SUBDIVISION: WALNUT GLEN ZONING: R -4.5 BLOCK: LOT: 006 JURISDICTION: TIG REMARKS: .Re-roof existing dwelling, enlarge kitchen add garage, and install new windows. BUILDING REISSUE: STORIES: 1 FLOOR AREAS REQUIRED SETBACKS REQUIRED CLASS OF WORK: ALT HEIGHT: FIRST: 321 sf BASEMENT: sf LEFT: 15 SMOKE DETECTORS: Y TYPE OF USE: SF FLOOR LOAD: 40 SECOND: sf GARAGE: 396 sf FRONT: 24 PARKING SPACES : TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: sf RIGHT: 15 VALUE: $ 40,000.00 OCCUPANCY GRP: R3 BDRM: BATH: 1 TOTAL: sf REAR: 16 PLUMBING SINKS: 1 WATER CLOSETS: 1 WASHING MACH: LAUNDRY TRAYS: RAIN DRAIN: TRAPS: LAVATORIES: 2 DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: SF RAIN DRAINS: 1 CATCH BASINS: TUB /SHOWERS: 1 GARBAGE DISP: 1 WATER HEATERS: WATER LINES: BCKFLW PREVNTR: GREASE TRAPS: OTHER FIXTURES: MECHANICAL FUEL TYPES FURN < 100K: BOIUCMP < 3HP: VENT FANS: 1 CLOTHES DRYER: GAS FURN > =100K: UNIT HEATERS: HOODS: 1 OTHER UNITS: MAX INP: btu FLOOR FURNANCES: VENTS: 2 WOODSTOVES: GAS OUTLETS: ELECTRICAL ■ RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS 1000 SF OR LESS: 1 0 - 200 amp: 0 - 200 amp: W /SVC OR FDR: 1 PUMP/IRRIGATION: PER INSPECTION: • EA ADD'L 500SF: 201 • 400 amp: 201 • 400 amp: 1st W/O SVC /FDR: - SIGN /OUT LIN LT: PER HOUR: LIMITED ENERGY: 401 - 600 amp: 401 - 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT: . MANU HM/SVC /FDR: 601 - 1000 amp: 601 +amps- 1000v: MINOR LABEL: 1000+ amp/volt : • PLAN REVIEW SECTION Reconnect only: >=4 RES UNITS: SVC /FDR> =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC: ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM: INTERCOM/PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVE SIGNL: GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR: HVAC: DATA/TELE COMM: • NURSE CALLS: TOTAL # SYSTEMS: Owner: Contractor: TOTAL FEES: $ 1,041.83 S M SCHLESINGER S M BUILDERS This permit is subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and 7000 SW HAMPTON ST 7000 SW HAMPTON ST all other applicable laws. All work will be done in #124 SUITE 124 accordance with approved plans. This permit will expire if TIGARD, OR 97223 TIGARD, OR 97223 work is not started within 180 days of issuance, or if the work is suspended for more than 180 days. ATTENTION: Phone: Phone: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set Reg #: LAC 86533 forth in OAR 952- 001 -0010 through 952- 001 -0080. You may obtain copies of these rules or direct questions to • OUNC by calling (503) 246 -1987. REQUIRED INSPECTIONS • Erosion 844 -8444 Post/Beam Mechanical Mechanical Insp Shear Wall Insp . Plumb Final • Grading Inspection Underfloor insulation Plumb Top Out Insulation Insp Final inspection Footing Insp Crawl Drain /Backwater Electrical Service Rain drain Insp ORIGINAL Foundation Insp Footing /Foundation Dr; Electrical Rough In Electrical Final Post/Beam Structural PLM /Underfloor Framing Insp Mechanical Final Issued By : 1 t/, aLUL.. P ermittee Signature f t4.itx -41AAL—e62Lfr4dfr-- . Call (503) 639 -4175 by 7:00 p.m. for an inspection needed the next business day CITY OF TIGARD Residential Building Permit Application Plan Check# / - P '13125 aiW HALL BLVD. Ad ditions or Alterations Recd By C�— T OR 97223 Single Family Detached or Attached (Duplex) Date Recd Ger - t5_s_ 9 y t d Att � p � Date to P.E. G� G5= 2 V 503 - 639 -4171 Date to DST ® ®- BI- 41 F 503 - 684 -7297 174, Permit # yttST 94 - ( 453H-7. Print or Type Called (0 R Incomplete or illegible applications will not be accepted 1/: / Gtr Alte- Name of Project Name Job SM Sr-hi PRi r RP DESIGNER Builder Design' _ Site A ddress Architect Mailing Address Address - 11125 NE Weidler //$ r44 Shrope Ct Tigard' City /State Zip Phone Name SM $rhl eel r, r P r tland, OR 97220 252 -3453 Owner Mailing Address C S A 7000 SW Hampton St. #124 City /State Zip Phone Engineer Mailing Address 321 SW 4th Ave. 4th floor Tigard, OR 97223 968-6500± City /State Zip Phone General Name Portland,OR 97204 228 -3848 Contractor SM Builders Describe work New 0 Addition 0 Alteration 0 Repair 0 Mailing Address to be done: Prior to permit 7000 S W Hampton , t. #124 Additional Description of Work: r - roofing ,new windows issuance, a copy City /State Zip Phone enlarging kitchen, adding a garage of all licenses Tigard, OR 97223 968 -6500 ep c are required if Oregon Const. Cont. Board Exp. Date PROJECT expired in COT Lic.# VALUATION $ 40,000.00 database CCB 86533 11 -0¢-- OC Mechanical Name NEW CONSTRUCTION ONLY: R'd( „3_3 Sub- Sq. Ft. House: Sq. Ft. Garage • Contractor Mailing Address � � JN: Prior to permit Indicate the restricted energy installation by the electrical issuance, a copy City /State Zip Phone subcontractor in the following areas of all licenses Restricted Audio /Stereo are required if Oregon Const. Cont. Board Exp. Date Energy System Alarms expired in COT Lic.# Installations Vacuum Irrigation database System System Plumbing Name (check all that Other: Sub- Matt Nelson apply) Contractor Mailing Address Corner Lot YES NO Flag Lot YES NO (check one) (check one) Has the Subdivision Plat recorded? N/A YES NO Prior to permit City /State Zip Phone issuance, a copy 816 of all licenses are Oregon Const. Cont. Board Exp. Date required if Lic.# expired in COT I hearby acknowledge that I have read this application, that the database Plumbing Lic. # Exp. Date information given is correct, that I am the owner or authorized agent of the owner, and that plans submitted are in compliance with . Oregon State laws. Name Signa r- of a wner /A . nt Date Electrical Atlas Electrical :old /. - .___ _ ........---. /0 = ' Sub Mailing Address o act Person Name P on • Contractor 4403 SE Rothe 1 �J.'03. ?68'e50O City /State Zip Phone • Prior to permit issuance, a copy Milwaukee, OR 659 -2212 FOR OFFICE USE ONLY: W)9`/Ju'T LOr6o of all licenses are Oregon Const. Cont. Board Exp. Date Plat #: Ma /TL #: required if Lic.# p expired in COT 1532 9 -3 -00 a,i0 Ma - tai 6 database . Electrical Lic. # Exp. Date Setbacks: Zon - � 5 Sol / C 10-1-00 /f/ Electrical Supervisor Lic. # Exp. Date Engineering Approval: Planning Approval: TIF: 10915 10 -1 -00 61- tsts \fbrms\sfaddalt.doc 7/28/99 PERMIT NO. r11refq - nol y EROSION CONTROL INSPECTION REPORT DATE 14-A6-00 INSPECTOR G! PL3urko Hew OWNER/PERMITEE 3 /`.) (3u ;kiev 5 6 SUBDIVISION t( )a f'ti�r C /ey LOT Unified Sewerage Agency of Washington County SITE ADDRESS IN SS Sol 54eic a r. APPROVED FINAL INSPECTIO THIS SITE MEETS THE POST - CONSTRUCTION EROSION CONTROL STANDARDS SET FORTH IN U.S.A. RESOLUTION AND ORDER. NOTE: IF POST = CONSTRUCTION EROSION CONTROL MEASURES ARE STILL BEING EMPLOYED ON THIS SITE TO MEET CRITERIA FOR AN APPROVED FINAL INSPECTION, THE MEASURE(S) MUST REMAIN IN PLACE UNTIL LANDSCAPING IS COMPLETE OR PERMANENT GROUND COVER IS ESTABLISHED. A COPY OF THE FINAL EROSION CONTROL INSPECTION REPORT MUST BE FORWARDED TO THE NEW OWNER, AT WHICH TIME NEW OWNER ASSUMES THE RESPONSIBILITY FOR MAINTENANCE, REPAIR AND REMOVAL. OTHER THANK YOU FOR YOUR COOPERATION! DATE a-1 -2 6 - O d TIME //;0a INSPECTOR , -- PHONE 9 ,'6 5/5/00 Activities for Case #: MST1999 -00347 4:52:53 PM Assigned Hold Updated Activity Description - Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA005 Application received 10/8/99 GEO RECD No Hold GEO 10/15/99 MSTA008 Permit Created 10/15/99 GEO DONE No Hold GEO 10/15/99 MSTA010 Check for prcl. restrict. 10/15/99 GEO DONE No Hold GEO 10/15/99 MSTA012 Plans routed to Plans Examiner 10/15/99 GEO SENT No Hold GEO 10/15/99 MSTA026 Plans approved by PIn Examiner No Hold BT2 10/19/99 MSTA030 Reviewed plans routed to DSTS No Hold BT2 10/19/99 MSTA700 Erosion 844 -8444 10/19/99 10/19/99 10/28/99 PASS No Hold RB 12/7 /99 Approved by CPB. MSTA703 Grading Inspection No Hold BT2 10/19/99 MSTA705 Footing Insp 10/19/99 10/19/99 1217/99 RB PASS No Hold RB 12/7/99 Mono Pour MSTA706 Foundation Insp 10/19/99 10/19/99 12/7/99 RB PART No Hold RB 12/7/99 Upper wall Mono pour/ Lower wall footing only ! 1. Extend shelf of lower footing • to 10- inches each side. 2. garage wings require SttB -28's and HD -6A's. • 3. provide garaghe retaining . wall rebar at vertical as per - plans & engineering. 4. Low point drain in crawl required with a Back- Water,. Valve. NOTE: Footing Drain, Water- proofing, and Dampproofing req'd at garage - or lower level. MSTA710 Post/Beam Structural 10/19/99 10/19/99 12/20/99 TLP PASS No Hold TLP 12/20/99 no plumb. or mech. at this time MSTA711 Post/Beam Mechanical 10/19/99 10/19/99 1/4/00 TLP PASS No Hold AKJ 4/25/00 MSTA712 Underfloor insulation 10/19/99 10/19/99 No Hold BT2 10/19/99 • • MSTA713 Crawl Drain /Backwater valve 10/19/99 10/19/99 1/6/00 MRS PASS No Hold MRS 1/6/00 MSTA714 Footing /Foundation Drain 10/19/99 10/19/99 No Hold . BT2 10/19/99 • MSTA717 PLM /Underfloor 10/19/99 10/19/99 No Hold BT2 10/19/99 MSTA720 Mechanical Insp 10/19/99 10/19/99 1/4/00 TLP PASS No Hold AKJ 1/4/00 MSTA722 Plumb Top Out 10/19/99 10/19/99 2/3/00 MRS PASS No Hold AKJ 2/3/00 MSTA723 Electrical Service • 10/19/99 10/19/99 1/13/00 BRP PASS No Hold AKJ 1/18/00 MSTA724 Electrical Rough In 10/19/99 10/19/99 No Hold BT2 10/19/99 • • Page 1 of 3 5 /5 /00 Activities for Case #: MST1999 -00347 4:52:53 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA725 Framing Insp 10/19/99 10/19/99 V NOTE No Hold RDP 1/21/00 The following revisions have been approved for the garage floor joist hangers. New hangers shall be HU212 -2. Engineering is on file. ?s call Bob P MSTA726 Shear Wall lnsp 10/19/99 10/19/99 No Hold BT2 10/19/99 MSTA740 Insulation Insp 10/19/99 10/19/99 2/18/00 TLP PASS No Hold AKJ 2/21/00 MSTA755 Rain drain Insp 10/19/99 10/19/99 1/6/00 MRS PASS No Hold MRS 1/6/00 MSTA790 Electrical Final 10/19/99 10/19/99 3/15/00 BRP FAIL No Hold AKJ 3/15/00 not ready, fixtures not installed outdoor MSTA795 Mechanical Final 10/19/99 10/19/99 4/25/00 RB PASS No Hold ' AKJ 4/25/00 MSTA797 Plumb Final 10/19/99 10/19/99 4/20/00 MRS FAIL No Hold AKJ 4/20/00 canc, house not ready MSTA798 Final inspection 10/19/99 10/19/99 No Hold BT2 10/19/99 MSTA032 DST Post - Review Completed 10/22/99 GEO DONE No Hold GEO 10/22/99 MSTA080 (F) Ready to issue 10/22/99 GEO DONE No Hold GEO 10/22/99 MSTA092 (F) Issue combination permit 10/26/99 BON DONE No Hold BON 10/26/99 MSTA097 Issue electric signature form 11/4/99 SLT RECD No Hold ST 11/4/99 MSTA723 Electrical Service . 11/1/99 11/1/99 11/1/99 BP FAIL No Hold VT 11/1/99 manufacturers of alum. wire • . require that anti - oxidant be used on all terminations. It is recommended that a licensed contractor review and test this installation before system is V . re- energized. Proper grounding and bonding must be performed • and verified. MSTA706 Foundation lnsp 12/17/99 12/17/99 12/17/99 RB PART No Hold RB 12/17/99 GARAGE ONLY ! (Lower wall) - 1. Displace water. . 2. Remove down spout from footing print. 3. Place HD's at garage wings NOTE: Refer to report dtd. 12 -7 -99 RB and complete as . V needed. MSTA706 Foundation Insp 12/20/99 12/20/99 12/20/99 TLP PASS No Hold TLP 12/20/99 retaining wall garage area - MSTA735 Gas Line Insp 1/4/00 1/4/00 1/4/00 TLP PASS No Hold AKJ 1/4/00 MSTA704 Sewer Inspection 1/6/00 MRS DONE No Hold MRS 1/6/00 Page 2 of 3 5/5/00 Activities for Case #: MST1999 -00347 4:52:53 PM Assigned • Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA704 Sewer Inspection • 1/7/00 RB PASS No Hold RB 1/7/00 Already passed by MS 1 -6-00. . OPEN TRENCH: MADE ANOTHER INSPECTION TO SATISFY CONTRACTOR. NOTE: If this residence was on a septic system, a permit is • required, AND verification of pump and fill. MSTA707 Slab Insp • 1/19/00 KS FAIL No Hold AKJ 1/19/00 hangers supporting floor joist at susp gar floor need to specify 3000 lbs MSTA725 Framing Insp 1/24/00 1/24/00 1/24/00 TLP PART No Hold AKJ 1/24/00 garage floor framing and eng hangars app MSTA715 Plm /undslab Insp 2/3/00 2/3/00 2/3/00 - MRS PASS No Hold AKJ 2/3/00 MSTA725 Framing Insp 2/13/00 2/13/00 2/11/00 TLP PASS No Hold AKJ 2/13/00 MSTA723 Electrical Service 2/13/00 2/13/00 2/11/00 TLP PASS No Hold AKJ 2/13/00 MSTA724 Electrical Rough In 2/13/00 2/13/00 2/11/00 TLP PASS No Hold AKJ 2/13/00 MSTA095 Issue plumbing signature form 3/6/00 ST DONE No Hold ST 3/6/00 Change of contractor MSTA095 Issue plumbing signature form 3/14/00 SLT RECD No Hold ST 3/21/00 change in contractor (previous change 3/6/00 not correct plumber) MSTA199 3/20/00 JMT DONE No Hold JMT 3/20/00 plumbing & building final request denied. Have not received plumbing signature form. called Miles S. and left voice mail message MSTA790 Electrical Final 3/20/00 CD FAIL No Hold AKJ 3/20/00 elec must be 100% complete, all fixtures and deviced installed before final MSTA790 Electrical Final . 4/19/00 CD FAIL No Hold AKJ 4/19/00 reschedule MSTA790 Electrical Final 4/21/00 CD FAIL No Hold AKJ 4/24/00 provide discount switch for hydro tub, GFCI MSTA797 Plumb Final 4/21/00 MRS FAIL No Hold AKJ 4/24/00 no answer MSTA790 Electrical Final 4/24/00 CD PASS No Hold AKJ 4/24/00 MSTA797 Plumb Final 4/24/00 MRS PART No Hold AKJ 4/24/00 1) water heater needs to be strapped . 2) PRV needs to be run out check strapping at bldg final MSTA797 Plumb Final 4/25/00 RB PASS No Hold AKJ 4/25/00 MSTA799 Building Final • - . 4/25/00 RB FAIL No Hold AKJ 4/25/00 usa erosion app req, only issue MSTA970 Case Fineled 4/26/00 JMT DONE No Hold JMT 4/26/00 Approved USA Final Inspection received • Page 3 of 3 CITY OF TIGARD BUILDING INSPECTION DIVISION 4 0, /q4q_ 0034-7 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requests L r(J\(2 _ _L. 4/L o/4 d AM PM BLD Location I t 4SS ¶ Suite MEC Contact Person .- + �s Ph 9 eio— 6 coo PLM / , Contractor Ph SWR i lir ��BUILDING ,N Tenant/Owner ELC Ild re ' Retaining Wall ELR Footing Access: Ar- Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing 1' L,M ^ /� c II�I�� V 7 11,L ) Insulation i Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: PART FAIL PLU ING Post & Beam • Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab • Low Voltage Fire Alarm Final - - PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain Catch Basin [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA b A. • •roach /Sidew Ik ` � S � - s Date 1 \\ 1 A 9 lb 6 Inspector 1� ) Ext l III_ Ir 1 - .PASS PART FAIL DO NOT REMOVE this inspection record from the job site. /44,7 600397 CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 • Business Line: 639 -4171 BUP a "2 ' Date Requested 1/ /O 1 AM N PM BLD Location C 11 / 5 S k Suite MEC Contact Person 1 /0 Ph q6' PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam . Ext Sheath /Shear Int Sheath /Shear Framing Insulation - Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL Service Rough In UG /Slab Low Voltage Fire Alarm fr Or) PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date V Other d Ins _ Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION 2199"093q 7 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 MST O, �� 1 BUP Date Requested P 7 . c AM PM 1 � S BLD Location 11 t 4 SS S S Y�n ) dd Suite MEC Contact Person A 1.Q Ph q(p g - (oSCO PLM Contractor Ph SWR = UILDINV Tenant/Owner ELC Retaining Wall ELR Footing Foundation Access: v5ee hMSS (n , gip FPS Ftg Drain 2S • �) SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam � ^ Ext Sheath /Shear C� - t n 6 ),)or-10 (l/- Int Sheath /Shear Framing Insulation Drywall Nailing WisATI A Firewall W/MMALA Fire Sprinkler � ✓ /� Fire Alarm v 0 Susp'd Ceiling • Roof Misc: 4 in. PASS PART a �LUMBI o Ik.5 9X 5 'Le.-v\" Post & Beam Under Slab Top Out �'' ' n Water Service ��•/■1/4 ` � ‘i. 't�"�/� G�.� V v ` Ss v�.� Sanitary Sewer H Rain Drains - • RT FAIL ANI Pos : - ea ' /0 -0 Rough In T Gas Line Smoke Dampers PART FAIL TRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final—/ • . SS PART FAIL �( �/- �,(,( I G\ CAN SIT _ I 4 _ a � ���? V I CA � V C� Backfill /Grading Sanitary Sewer Storm Drain ` \ ( [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin 1v Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA A• •roach /S de k ' • 4/2- 0 tksR ' ms , , ' ate / Inspector ` � Ext =ASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION W 'MST-DI RM9 —CO$ 3ci 7 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 1 a 0D AM x PM \ ' i 7 BLD Location 1 1 4 S $ Sh Suite MEC Contact Person 1 Le/3 Ph ow PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear l _ f - Int Sheath /Shear [Q/ rte._ Q A.c �� L ''J �C Framing ''�-)) �C�� l` Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm 6"- 4r12~\ Susp'd Ceiling (( - �( J (� ` Roof j V [1 / �✓`5 Misc: T �.l Final PASS PART FAIL I V � �5 C 1 v MBiR Post & Beam Under Slab Top Out Water Service [ 1 „ — 6 _ S ''1' [il/1 c--12-- S Rain Rain D �� ��....Q. COH 51..--)5 x/1/4_ PART FAIL .r2. v 2 N ANICAL Post & Beam 0 Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA T Other oach /Sidewalk Date \/ 6 V Inspector ExtT Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION �9 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 MST j - CO7 5/7 BUP Date Requested 4" AM PM BLD Location ll V3 5 Suite MEC Contact Person Ph PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing . 1 Firewall L w "/ Fire Sprinkler / Fire Alarm Susp'd Ceiling Roof Misc: Final r j � �(��7/ „77: - zz -f t- Ci — PASS PART FAIL /2 UMBI Post & Beam Under Slab Top Out Top Out Water Service Sanitary Sewer Rain Drains CAS ✓ PASS FAIL MECHA • AL ,✓� Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer • Storm Drain [ . ] Reinspection fee of $ required before next inspection. Pay at City Hail, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date Other D v Inspector / , // Ext. Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 1 - co 3 c0 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 3// S/( ) AM PM BLD Location I I t-/S5 S In � nye, Suite /,, I/ c�v�, MEC 11 Contact Person UA Ph (U is to QD PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGT Crawl Drain e rain Inspection Notes: p /�,� Slab / /� v �' SIT Post & Beam Ext Sheath /Shear .bV KY- Insulation Ina Sheath /Shear i�� // Th{ lm S1 ' Framing /f� q ,�•, , I_ Drywall Nailing 51)11 6x 119 Firewall Fire Sprinkler Fire Alarm fr ow/ Susp'd Ceiling Roof Misc: �� � Final PASS PART FAIL " '/ / ` ir li �Ii�gr11 /rL.� MBI Post & Beam Under Slab ��` /j � ,aA ,, 14.dlL_ _. 1 Top Out Water Service / / Sanitary Sewer Rain Drains - SS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ _ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk U i D Other Date �� Inspector Ext / Final • PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION Msr ? 9 -0o St/ 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 01 BUP Date Requested / l/ X AM PM BLD Location (1 y 5 S sorb Suite • MEC Contact Person /l4\ L & S. Ph b'bbo8 4SPiD Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing 411. Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof F inal l / Final PASS P RT FAIL r'�! UMBI ! Post & Beam �L/ v Under Slab Top Out Water Service / Sanitary Sew: Rai oral in- - PART Alleff "CHANICALTI Post & Beam L- Rough In Gas Line Smoke Dampers Final PASS PART FAIL • ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: _ [ ] Unable to inspect - no access ADA Approach /Sidewalk f Other Date ti ` 1 1 r Inspector Ex Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.