Permit CITY OF TIGARD MASTER PERMIT
���i 1/4-'-1•11. „i,r, DEVELOPMENT SERVICES PERMIT # - MST98 -0 94
13125 SW Hall Blvd., Tigard, OR97223 (503)639 -4171 DATE ISSUED: 07/29/98
PARCEL: 2S109AB -06000
SITE ADDRESS...:13O95 SW STARVIEW DR
; SUBDIVISION •FORAN ZONING: R -7
' BLOCK LOT :002 JURISDICTION: TIG
Remarks: Path I - Single family detached dwelling.
BUILDING
REISSUE: STORIES • 2 FLOOR AREAS BASEMENT...: 430 sf REQUIRED SETBACKS -- REQUIRED —
CLASS OF WORK.:NEW HEIGHT • 35 FIRST • 949 sf GARAGE • 594 sf LEFT • 5 SMOKE DETECTRS: Y
TYPE OF USE...:SF FLOOR LOAD : 40 SECOND...: 1321 sf FRONT • 20 PARKING SPACES: 2
TYPE OF CONST.:5W DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 5
'I OCCUPANCY GRP.:R3 BDRM: 3 BATH: 3 TOTAL : 2270 sf VALUE..$: 169576 REAR • 33
PLUMBING
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 1% TRAPS • 0
LAVATORIES • 3 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 1' SF RAIN DRAINS: 1 CATCH BASINS..: 0
TUB /SHOWERS...: 2 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1'. BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
MECHANICAL
FUEL TYPES— FURN (100K ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS : 4 CLOTHES DRYERS: 1
FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS : 1 OTHER UNITS...: 1
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES • 0 GAS OUTLETS...: 1
i , — — — ELECTRICAL -
- RESIDENTIAL UNIT— — SERVICE /FEEDER— —TEMP SRVC /FEEDERS— — BRANCH CIRCUITS — -- MISCELLANEOUS — - -ADD'L INSPECTIONS -
1m SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 5 201 - 400 alp..: 0 201 - 400 alp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0
LIMITED ENERGY.: 0 401 - 600 alp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0
MANF HM /SVC /FDR: 0 601 - 1m amp.: 0 601 +amps- 1' v: 0 MINOR LABEL -10: 0
1m+ amp /volt.: 0 — PLAN REVIEW SECTION - -- —
Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC:
ELECTRICAL - RESTRICTED ENERGY --
A. SF RESIDENTIAL B. COMMERCIAL
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: 0TH: :: X BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK • INSTRUMENTATION : MEDICAL OTHR: ..
HVAC DATA /TELE COMM.: NURSE CALLS TOTAL B SYSTEMS: 0
Owner: ---- Contractor: — - -- TOTAL FEES:$ 5202.70
CLIFF WAIBEL C C WAIBEL CONSTRUCTION CO This permit is subject to the regulations contained in the
879 NW 10TH 879 NW 10TH Tigard Municipal Code, State of Ore. Specialty Codes and all
HILLSBORO OR 97124 HILLSBORO OR 97124 other applicable laws. All work will be done in accordance
with approved plans. This permit will expire if work is
Phone B: 640 -3110 Phone 0: 640 -3110 not started within 180 days of issuance, or if the work is
Reg 0..: 25454 suspended for more than 180 days. ATTENTION: Oregon law
requires you to follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth in OAR 952-001 -0010 through OAR 952 001 -0080. You may obtain copies of these rules or
direct questions to OUNC by calling (503)246 -1987.
REQUIRED INSPECTIONS
Erosion 844 -8444 Post /Beam Meehan Electrical Servi Gas Line Insp Electrical Final
Grading Inspecti Crawl Drain /Back Electrical Rough Insulation Insp Mechanical Final
Footing Insp PLM /Underfloor Framing Insp Rain drain Insp Plumb Final
Foundation In , •echanical Insp Shear Wall Insp Water Service In Building Final
Post /Beam S uct P b Top Out Low Voltage Appr /Sdwlk Insp , 1'
Issued •y: ',/i _! , �/ Permittee Signature /,� i,
+ + + + + ++ - + + + +± + + + + + + + + + + + + ++ + + + + + + + + + + + + + + + + + + + + + + + + + + ++ + +; +' + + ++ + + + ++
Call 639 -4175 by 7:00 p.m. for an inspection needed the .ext business day
A
Plan Check # 7' o?a
CITY OF TIGARD Residential Building Permit Application Rec'd By L
13125 SW'HALL BLVD. New Construction Additions or Alterations Date Rec'd 7,41,'
TIGARD, OR 97223 Single Family Detached or Attached (Duplex) Date to - . - E.
V 503 - 639 -4171 Date to DST 3 - 2 -
■ F 503 - 684 -7297 Permit # / ', — !'y
Print or Type � ( Called4 se _, <�`[
�2 p- r
Incomplete or illegible applications will not be accepted 9e' _0J 2
Name of Project Na e
Job ap I`,g19CP, Lo' a iling rt�0 � Des, Nei" Architect Mailing Add
Address Site 3 S Sill 70$Q S w f Su/le/49
/4✓
5 t�v -
C /S - ta � te /� Q p Zi 23 P hone
Name / W4:10 99 (., _ A /X Of �72- Liss)
Nae
CLt �� P,L e
Owner mailiag Ad J ess �) 1-14.""
En ineer Mailing Address
C'cy/$tateg - Zip P h h one g /11LL.5 97i 7 U L iD 3110 City/State Zip Phone
General Name
Contractor C C Lf) t'beL Cop. -f a Describe work New p( Addition 0 Alteration 0 Repair 0
Mail' ress �/ to be done:
Prior to permit /� (,J /v Ti- Additional Description of Work:
issuance, a copy 9 at Zi Phone
of all licenses !i't a S $ aro a ` 712 444/0 3//
are required if Oregon Const. Cont. Board Exp. Date �- PROJECT
expired in COT Lic.# 5y /Z 5- VALUATION $ 166 71 /a
2,5�/
database 7 /
Mechanical Name in NEW CONSTRUCTION ONLY:
Sub- /A)t f e r 5) tm + Sq. Ft. House: q. Ft. Garage
Contractor Mailing Address s -- P, 2272 Lisa /.44,47 ,aa 530
Prior to permit 1 13o !1) t .) 2 3 j 0 Corner Lot YES NO Flag Lot YES NO
issuance, a copy Ci /Stat Z•iu Phone it (check one) �- (check one)
of all licenses Hi l[," h 9e0 9/12Li G4 $ /.5z/ 7 Restricted Audio /Stereo Burglar
are required if Oregon Const. Cont. Board 47& ner gY System Alarm
E expired in COT Lic.# database 13 /2 Installation j � ( Garage Door HVAC
Plumbing Name y\ Opener _ Systems
Sub- n -- KJh, f f') p m bt . (check all that Other:
Contractor Mailing Address apply)
�� �1 Will the electrical subcontractor wire for all Y NO
fl o -5 0 N,id • P Of- restricted energy installations?
Prior to permit �ity/Sla�t �� 22 " Phone -
5. Has the Subdivision Plat recorded? N/A 3Ei NO
issuance, ce, a copy p G ! 7
of all licenses are Oregon Const. Cont. Board Exp. Date / � �� /
required if Lic. / Re of MST #: Solar Compliance
expired in COT 1/ /,'2 3g7 /� / (Calculation Attached)
database Plumbing Lic. # Exp. Date I hearby acknowledge that I have read this application, that the
37 /63 P r b r /1-9e? information given is correct, that I am the owner or authorized
Name agent of the owner, and that plans submitted are in compliance
n) with Oregon State laws.
Electrical A p E l e c . - •(• Si• - . , e •j ,own / nt Date ^7
Sub- Mailing Address / 7� 9R
• Contractor ...567,05 /1)//) (44-A P�i /1lL I)2, ont. • rer o Name Phone #
City/State Zip Z. / / }bed _440-310
Prior to permit Psi-vest-6p, FOR O USE ONLY:
issuance, a copy g i f h 357-.2g3\ Plat #: Map/TL #:
of all licenses are Oregon Const. Cont. Board Exp. Date' /46 - /3 /1 ? , - -
r e q u i r ed uired if Lic.# f /
expired in COT 3.5743 1-14'-et:, Setbacks: 6 Zone: Solar:
database Electrical Lic. # Exp. Date
Engineering Approval: Planning Approval: TIF:
3 q - JO D1 - n: A ,zh„ ?///5?
./f S I4 L_ 7L/96-- X977 9 e ,9z
2& V-e92,U wG , /L' I:SFREM.DOC (DST) 4/97
� F� ///,/<&-- 60A //
1
CITY OF TIG
OREGON
INTENT TO HAUL EXCAVATION
1, CL,' //A -I lej, (print name), hereby certify that all excavation
material on the subject property will be removed from the site and not be placed as fill,
except for that amount necessary to back -fill the foundation ONLY. I understand that
failure to remove the excavation material will result in the requirement to remove the
material or obtain a grading permit by submitting grading plans prepared by a licensed
engineer accompanied by a geo- technical report regarding the placement of the
excavation material as fill.
nat
g
Si Date 7-7 7P
Job Address: 130q5 5 fit
Subdivision: }n) 0j¢6P Lot:
131 25 SWi.111(1:: g;igard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
•
8/23/99 Activities for Case #: MST98 -00294
1:15:25 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes • • ,
MSTA005 Application received 7/7/98 DLH RECD DLH 7/8/98
MSTA008 Permit Created 7/8/98 DLH DONE DLH 7/8/98
MSTA010 Check for prcl. restrict. 7/8/98 DLH DONE DLH 7/8/98
MSTA012 Plans routed to Plans Examiner 7/8/98 DLH SENT DLH 7/8/98
MSTA026 Plans approved by PIn Examiner 7/23/98 RT PASS BT2 7/23/98
MSTA030 Reviewed plans routed to DSTS 7/23/98 RT PASS BT2 7/23/98 • •
MSTA032 DST Post - Review Completed 7/24/98 JSD PASS JSD 7/24/98
MSTA700 Erosion 844 -8444 DLH 7/8/98
MSTA703 Grading Inspection BT2 7/23/98 34% slope HAS SIGN THE
INTENT TO HAUL FORM
MSTA705 Footing Insp 8/21/98 KS PASS J *H 8/30/98 1. USA okay 2. Ufer tagged 3.
Will RE:-backfill @ lower
• - footing @ (intemal) garage also
provide drainage"
MSTA706 Foundation Insp 8/28/98 KS FAIL J*H 8/28/98 1. General contractor. Will
submit revisions to Bldg. Dept.
deleting isolated piers at
suspended garage floor. Will
bear on (pony wall at rear of
garage). Also will reduce
height of cut at crawl space and
will provide drainage &
compacted backfill (gravel) to
• maintain required (ratio). 2.
Contractor indicated foundation
vents at rear of structure will be
installed in pony wall. 3.
Provide detail (ledger
supporting garage floor system
needs to indicate size of beam
bolting pattern).
MSTA710 Post/Beam Structural 9/8/98 KS PASS J *H 9/8/98 Crawl at lower (no heat or
• plumbing).
MSTA711 Post/Beam Mechanical RB 9/11/98 None'at lower level only -
• overhead. Crawl space to be
checked at mech rough.
MSTA713 Crawl Drain /Backwater valve 9/11/98 RB PASS RB 9/11/98 Perf/w /sock- ok •
MSTA717 PLM /Underfloor RB 9/11/98 At lower level only. Crawl space
to be checked at top -out.
MSTA720 Mechanical Insp DLH 7/8/98
MSTA722 Plumb Top Out 1/21/99 RB PART RB 1/25/99 Over -board hole in floor joist
over kitchen- 3 -inch waste line-
to be corrected before framing.
Secure tub /shower unit upstairs
at ea. stud.
Page 1 of 4
8/23/99 Activities for Case #: MST98 -00294
• 1:15:25 PM
•
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA723 Electrical Service • 2/4/99 BRP PASS CD 2/5/99 •
MSTA724 Electrical Rough In 2/4/99 BRP PASS CD 2/5/99 use permanent ink or type on
panel scedule - check ground
. 'clamp on final
MSTA725 Framing Insp DLH 7/8/98
MSTA726 Shear Wall Insp 12/17/98 . RB FAIL J'H 12/18/98 a) Block and nail exterior
sheathing. b) Secure straps to •
exterior sheathing. c) At
• cantilever; add straps and LS50
brackets at 32 -inch centers. d)
• . Nail floor decking into cantilever
blocking 6- inches OC. e) Nail
exterior sheathing where
missed.
MSTA728 Low Voltage 2/4/99 BRP PASS CD 2/5/99 .
MSTA735 Gas Line Insp 2/10/99 KS PASS KBS 2/11/99 # gas pipnig pt test = 13.5
• - psi for 15 minutes (tag)
• . #344122
MSTA740 Insulation Insp 2/26/99 KS PART KBS 3/1/99 #-1- under floor not insulated @ .
this time
MSTA752 Rain drain Insp 9/11/98 RB PART RB 9/11/98 34 % slope- needs inspection
at/or before framing. Partially
covered !!! Unable to view
.entire system- by appearance,
adequately installed where able
to view.
MSTA761 Water Service Insp 9/11/98 RB PART RB 9/11/98 Test at Top -out. Seal thru hole
penetration at foundation.
•
MSTA765 Appr /Sdwlk Insp 4/16/99 MH PART AKJ 4/18/99 1) Install weep hole pipe at all
existing cut outs
. 2) Remove debris off the fire
truck turn around. Not a
stockpile spot.
MSTA790 Electrical Final 7/9/99 BRP PASS AKJ 7/11/99
MSTA795 Mechanical Final 7/23/99 RB FAIL AKJ 7/26/99 see bldg final 7/23/99
MSTA797 Plumb Final 7/21/99 MS• PASS • AKJ 7/21/99 fixtures need caulking
•
MSTA799 Building Final 7/23/99 DONE AKJ 7/25/99 Prior to a final inspection,
contractor shall install a 15 foot
long section of perforated drain
pipe in the utility trench to
coleect seepage. The collected
water should be then
. hardpipied to the creek or storm
sewer. See Report on file with
address. Also talk with Mike
• • White about this. Bob P - 3/2/99
MSTA080 (F) Ready to issue 7/24/98 JSD PASS JSD 7/24/98
Page2of4
•
•
8/23/99 Activities for Case #: MST98 -00294 . .
1:15:25 PM •
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA092 (F) Issue combination permit 7/29/98 DEB DONE DRA 7/29/98
MSTA095 Issue plumbing signature form 8/4/98 JMT RECD JT 8/4/98
MSTA097 Issue electric signature form 8/6/98 JMT RECD JT 8/6/98
•
MSTA706 Foundation Insp 8/31/98 KS PASS J'H 8/31/98 1. Ufer rod tagged. 2. Will add
fdn vents at pony wall of
suspended garage floor. 3.
Building, will submit revisions to
bldg. dept. (change of isolated
piers at garage floor system) to _
continuous ftg also needs to
specify spacing of studs and
• size. 4. Install anchor bolts size
and spacing as shown.
MSTA714 Footing /Foundation Drain 9/11/98 RB PASS RB '9/11/98 INTERIOR AND EXTERIOR !!!
• Already covered ! By
appearance and review, the
• system in part; which is
• uncovered, appears to be
• adequately installed and in
accordance with approved
• - plans and engineering.
MSTA761 Water Service Insp 9/11/98 RB 9/11/98
MSTA717 PLM /Underfloor 9/11/98 1/21/99 RB PART RB 1/25/99 Support underneath 3 -inch
waste for powder room W /C.
MSTA711 Post/Beam Mechanical 9/11/98 RB 9/11/98
•
MSTA726 Shear Wall Insp 1/13/99 RC FAIL ROC 1/13/99 NO PLANS ON SITE •
MSTA726 Shear Wall Insp 1/14/99 RB PART RB 1/14/99 Report dtd. 12 -17 -98 RB Via.
1 -13 -99 RC, all issues
completed EXCPET installation
of LS -50 brackets at rear
cantilever at 32 -inch centers.
. ' OK TO VIEW AT FRAMING.
MSTA726 Shear Wall Insp 2/17/99 RC FAIL ROC 2/17/99 LS50'S NOT INSTALLED AT
CANTILEVER 3RD NOTICE
MSTA726 Shear Wall Insp 2/17/99 , ROC 2/17/99
MSTA722 Plumb Top Out 2/17/99 2/22/99 RB PASS RB 2/23/99
MSTA722 Plumb Top Out 2/17/99 ROC 2117/99
MSTA722 Plumb Top Out 2/17/99 RC FAIL ROC 2/17/99 CORRECTION FOR .
STRUCTURAL NOT
• COMPLETE 2ND NOTICE
Page 3 of 4
•
•
8/23/99 Activities for Case #: MST98 -00294
1:15:25 PM •
Assigned Hold • Updated •
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA725 Framing Insp 2/17/99 RC FAIL ROC 2/17/99 SEE SHEAR AND PLUMB
THIS DATE 1. PROVIDE
ATTIC ACCESS TO ALL
. AREAS 30 " IN HEIGHT 2.
REPAIR FLOOR JOIST WHRE
• OVERBORED FOR
. PLUMBING 3. PROVIDE
PROOF OF INSUL IN
CANTILEVER
MSTA720 Mechanical Insp 2/17/99 RC FAIL ROC 2/17/99 FILL ALL HOLES IN RETURN
AIR PLENUM
MSTA720 Mechanical Insp 2/22/99 RB PASS RB 2/23/99 As per RC report dtd. 2- 17 -99: "'
MSTA725 Framing Insp 2/22/99 RB PASS RB 2/23/99 As per RC report dtd. 2- 17 -99. .
OK to insulate!
MSTA726 Shear Wall Insp 2/22/99 RB PASS RB 2/23/99 As per RC report dtd. 2- 17 -99.
OK to insulate!
MSTA725 Framing Insp • 2/26/99 KS PASS KBS 3/1/99 #-1- approved per RC .
correction list dated 2/16/99
MSTA720 Mechanical Insp - - 2/26/99 KS PASS KBS 3/1/99 #-1- approved per RC
correction list dated 2/16/99
MSTA765 Appr /Sdwlk Insp 7/25/99 7/25/99 7/23/99 MW PASS No Hold AKJ 7/25/99 RDP note (bldg final 3/2/99)
condition met
MSTA799 Building Final 7/26/99 7/26/99 7/23/99 RB FAIL No Hold AKJ 7/26/99 1) slope grade away from .
house on each side, maintain
. min 6" earth /wood sep.
2) remove debris from crawl
' 3) reinstall vent hood at water
heater provide sep. from hood
and flex water line
4) cover exposed metal duct
•
with insul at both underflr
- - locations where duct comes
thru wall
MSTA740 Insulation Insp 7/26/99 7/26/99 7/26/99 RB PASS No Hold AKJ 7/26/99
•
MSTA799 Building Final 7/26/99 7/26/99 7/26/99 RB PASS No Hold AKJ 7/26/99
MSTA752 Rain drain Insp 7/26/99 7/26/99 7/26/99 RB PASS No Hold AKJ 7/26/99 •
MSTA711 Post/Beam Mechanical 7/26/99 7/26/99 7/26/99 RB PASS No Hold • AKJ 7/26/99
MSTA795 Mechanical Final • 7/26/99 7/26/99 7/26/99 RB • PASS No Hold AKJ 7/26/99
MSTA960 (F) Issue Cert. of Occupancy 7/26/99 TIG RB DONE . No Hold JMT 8/23/99
Page 4 of 4 .
CITY OF TIGARD BUILDING INSPECTION DIVISION MST ci. ---OZ9
24 -Hour Inspection Line: 639 -4175 Business Line: 639-4 1
BUP
Date Requested "7- 7 ji � AM I M BLD
Location 1 20q(5 S411 Y \/j ) Suite MEC
Contact Person OA 4- Ph (OW) '31 ID PLM
Contractor Ph SWR
Yt1D�f1S T ` - Tenant/Owner ELC
etat ni T ng Wall ELR
Footing
N 1,,..4"1-1:1L; T a FP
Ftg Drain S
Foundation A ‹*; sj x l�Nc ''y<f 1-j �.�'� ���-
t• n. r= V.•. j.' air
1 ,
Crawl Drain Inspection Notes: SGN
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing L / . .
s — �
a w (�r�5
ail ing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
SS ART FAIL
ING •
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
rai
PART FAIL
Trf
196 155
Gas Line
Smoke Dampers
PART FAIL
TRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE •
Backfill/Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk C G
Other Date �/ q ! `I Inspector Ext
Final -
PASS PART FAIL - DO NOT REMOVE this inspection record from the job site.