Loading...
Permit CITY OF TIGARD MASTER PERMIT ���i 1/4-'-1•11. „i,r, DEVELOPMENT SERVICES PERMIT # - MST98 -0 94 13125 SW Hall Blvd., Tigard, OR97223 (503)639 -4171 DATE ISSUED: 07/29/98 PARCEL: 2S109AB -06000 SITE ADDRESS...:13O95 SW STARVIEW DR ; SUBDIVISION •FORAN ZONING: R -7 ' BLOCK LOT :002 JURISDICTION: TIG Remarks: Path I - Single family detached dwelling. BUILDING REISSUE: STORIES • 2 FLOOR AREAS BASEMENT...: 430 sf REQUIRED SETBACKS -- REQUIRED — CLASS OF WORK.:NEW HEIGHT • 35 FIRST • 949 sf GARAGE • 594 sf LEFT • 5 SMOKE DETECTRS: Y TYPE OF USE...:SF FLOOR LOAD : 40 SECOND...: 1321 sf FRONT • 20 PARKING SPACES: 2 TYPE OF CONST.:5W DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 5 'I OCCUPANCY GRP.:R3 BDRM: 3 BATH: 3 TOTAL : 2270 sf VALUE..$: 169576 REAR • 33 PLUMBING SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 1% TRAPS • 0 LAVATORIES • 3 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 1' SF RAIN DRAINS: 1 CATCH BASINS..: 0 TUB /SHOWERS...: 2 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1'. BCKFLW PREVNTR: 1 GREASE TRAPS..: 0 OTHER FIXTURES: 0 MECHANICAL FUEL TYPES— FURN (100K ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS : 4 CLOTHES DRYERS: 1 FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS : 1 OTHER UNITS...: 1 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES • 0 GAS OUTLETS...: 1 i , — — — ELECTRICAL - - RESIDENTIAL UNIT— — SERVICE /FEEDER— —TEMP SRVC /FEEDERS— — BRANCH CIRCUITS — -- MISCELLANEOUS — - -ADD'L INSPECTIONS - 1m SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 5 201 - 400 alp..: 0 201 - 400 alp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0 LIMITED ENERGY.: 0 401 - 600 alp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF HM /SVC /FDR: 0 601 - 1m amp.: 0 601 +amps- 1' v: 0 MINOR LABEL -10: 0 1m+ amp /volt.: 0 — PLAN REVIEW SECTION - -- — Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC: ELECTRICAL - RESTRICTED ENERGY -- A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: 0TH: :: X BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK • INSTRUMENTATION : MEDICAL OTHR: .. HVAC DATA /TELE COMM.: NURSE CALLS TOTAL B SYSTEMS: 0 Owner: ---- Contractor: — - -- TOTAL FEES:$ 5202.70 CLIFF WAIBEL C C WAIBEL CONSTRUCTION CO This permit is subject to the regulations contained in the 879 NW 10TH 879 NW 10TH Tigard Municipal Code, State of Ore. Specialty Codes and all HILLSBORO OR 97124 HILLSBORO OR 97124 other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is Phone B: 640 -3110 Phone 0: 640 -3110 not started within 180 days of issuance, or if the work is Reg 0..: 25454 suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001 -0010 through OAR 952 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503)246 -1987. REQUIRED INSPECTIONS Erosion 844 -8444 Post /Beam Meehan Electrical Servi Gas Line Insp Electrical Final Grading Inspecti Crawl Drain /Back Electrical Rough Insulation Insp Mechanical Final Footing Insp PLM /Underfloor Framing Insp Rain drain Insp Plumb Final Foundation In , •echanical Insp Shear Wall Insp Water Service In Building Final Post /Beam S uct P b Top Out Low Voltage Appr /Sdwlk Insp , 1' Issued •y: ',/i _! , �/ Permittee Signature /,� i, + + + + + ++ - + + + +± + + + + + + + + + + + + ++ + + + + + + + + + + + + + + + + + + + + + + + + + + ++ + +; +' + + ++ + + + ++ Call 639 -4175 by 7:00 p.m. for an inspection needed the .ext business day A Plan Check # 7' o?a CITY OF TIGARD Residential Building Permit Application Rec'd By L 13125 SW'HALL BLVD. New Construction Additions or Alterations Date Rec'd 7,41,' TIGARD, OR 97223 Single Family Detached or Attached (Duplex) Date to - . - E. V 503 - 639 -4171 Date to DST 3 - 2 - ■ F 503 - 684 -7297 Permit # / ', — !'y Print or Type � ( Called4 se _, <�`[ �2 p- r Incomplete or illegible applications will not be accepted 9e' _0J 2 Name of Project Na e Job ap I`,g19CP, Lo' a iling rt�0 � Des, Nei" Architect Mailing Add Address Site 3 S Sill 70$Q S w f Su/le/49 /4✓ 5 t�v - C /S - ta � te /� Q p Zi 23 P hone Name / W4:10 99 (., _ A /X Of �72- Liss) Nae CLt �� P,L e Owner mailiag Ad J ess �) 1-14."" En ineer Mailing Address C'cy/$tateg - Zip P h h one g /11LL.5 97i 7 U L iD 3110 City/State Zip Phone General Name Contractor C C Lf) t'beL Cop. -f a Describe work New p( Addition 0 Alteration 0 Repair 0 Mail' ress �/ to be done: Prior to permit /� (,J /v Ti- Additional Description of Work: issuance, a copy 9 at Zi Phone of all licenses !i't a S $ aro a ` 712 444/0 3// are required if Oregon Const. Cont. Board Exp. Date �- PROJECT expired in COT Lic.# 5y /Z 5- VALUATION $ 166 71 /a 2,5�/ database 7 / Mechanical Name in NEW CONSTRUCTION ONLY: Sub- /A)t f e r 5) tm + Sq. Ft. House: q. Ft. Garage Contractor Mailing Address s -- P, 2272 Lisa /.44,47 ,aa 530 Prior to permit 1 13o !1) t .) 2 3 j 0 Corner Lot YES NO Flag Lot YES NO issuance, a copy Ci /Stat Z•iu Phone it (check one) �- (check one) of all licenses Hi l[," h 9e0 9/12Li G4 $ /.5z/ 7 Restricted Audio /Stereo Burglar are required if Oregon Const. Cont. Board 47& ner gY System Alarm E expired in COT Lic.# database 13 /2 Installation j � ( Garage Door HVAC Plumbing Name y\ Opener _ Systems Sub- n -- KJh, f f') p m bt . (check all that Other: Contractor Mailing Address apply) �� �1 Will the electrical subcontractor wire for all Y NO fl o -5 0 N,id • P Of- restricted energy installations? Prior to permit �ity/Sla�t �� 22 " Phone - 5. Has the Subdivision Plat recorded? N/A 3Ei NO issuance, ce, a copy p G ! 7 of all licenses are Oregon Const. Cont. Board Exp. Date / � �� / required if Lic. / Re of MST #: Solar Compliance expired in COT 1/ /,'2 3g7 /� / (Calculation Attached) database Plumbing Lic. # Exp. Date I hearby acknowledge that I have read this application, that the 37 /63 P r b r /1-9e? information given is correct, that I am the owner or authorized Name agent of the owner, and that plans submitted are in compliance n) with Oregon State laws. Electrical A p E l e c . - •(• Si• - . , e •j ,own / nt Date ^7 Sub- Mailing Address / 7� 9R • Contractor ...567,05 /1)//) (44-A P�i /1lL I)2, ont. • rer o Name Phone # City/State Zip Z. / / }bed _440-310 Prior to permit Psi-vest-6p, FOR O USE ONLY: issuance, a copy g i f h 357-.2g3\ Plat #: Map/TL #: of all licenses are Oregon Const. Cont. Board Exp. Date' /46 - /3 /1 ? , - - r e q u i r ed uired if Lic.# f / expired in COT 3.5743 1-14'-et:, Setbacks: 6 Zone: Solar: database Electrical Lic. # Exp. Date Engineering Approval: Planning Approval: TIF: 3 q - JO D1 - n: A ,zh„ ?///5? ./f S I4 L_ 7L/96-- X977 9 e ,9z 2& V-e92,U wG , /L' I:SFREM.DOC (DST) 4/97 � F� ///,/<&-- 60A // 1 CITY OF TIG OREGON INTENT TO HAUL EXCAVATION 1, CL,' //A -I lej, (print name), hereby certify that all excavation material on the subject property will be removed from the site and not be placed as fill, except for that amount necessary to back -fill the foundation ONLY. I understand that failure to remove the excavation material will result in the requirement to remove the material or obtain a grading permit by submitting grading plans prepared by a licensed engineer accompanied by a geo- technical report regarding the placement of the excavation material as fill. nat g Si Date 7-7 7P Job Address: 130q5 5 fit Subdivision: }n) 0j¢6P Lot: 131 25 SWi.111(1:: g;igard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 • 8/23/99 Activities for Case #: MST98 -00294 1:15:25 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes • • , MSTA005 Application received 7/7/98 DLH RECD DLH 7/8/98 MSTA008 Permit Created 7/8/98 DLH DONE DLH 7/8/98 MSTA010 Check for prcl. restrict. 7/8/98 DLH DONE DLH 7/8/98 MSTA012 Plans routed to Plans Examiner 7/8/98 DLH SENT DLH 7/8/98 MSTA026 Plans approved by PIn Examiner 7/23/98 RT PASS BT2 7/23/98 MSTA030 Reviewed plans routed to DSTS 7/23/98 RT PASS BT2 7/23/98 • • MSTA032 DST Post - Review Completed 7/24/98 JSD PASS JSD 7/24/98 MSTA700 Erosion 844 -8444 DLH 7/8/98 MSTA703 Grading Inspection BT2 7/23/98 34% slope HAS SIGN THE INTENT TO HAUL FORM MSTA705 Footing Insp 8/21/98 KS PASS J *H 8/30/98 1. USA okay 2. Ufer tagged 3. Will RE:-backfill @ lower • - footing @ (intemal) garage also provide drainage" MSTA706 Foundation Insp 8/28/98 KS FAIL J*H 8/28/98 1. General contractor. Will submit revisions to Bldg. Dept. deleting isolated piers at suspended garage floor. Will bear on (pony wall at rear of garage). Also will reduce height of cut at crawl space and will provide drainage & compacted backfill (gravel) to • maintain required (ratio). 2. Contractor indicated foundation vents at rear of structure will be installed in pony wall. 3. Provide detail (ledger supporting garage floor system needs to indicate size of beam bolting pattern). MSTA710 Post/Beam Structural 9/8/98 KS PASS J *H 9/8/98 Crawl at lower (no heat or • plumbing). MSTA711 Post/Beam Mechanical RB 9/11/98 None'at lower level only - • overhead. Crawl space to be checked at mech rough. MSTA713 Crawl Drain /Backwater valve 9/11/98 RB PASS RB 9/11/98 Perf/w /sock- ok • MSTA717 PLM /Underfloor RB 9/11/98 At lower level only. Crawl space to be checked at top -out. MSTA720 Mechanical Insp DLH 7/8/98 MSTA722 Plumb Top Out 1/21/99 RB PART RB 1/25/99 Over -board hole in floor joist over kitchen- 3 -inch waste line- to be corrected before framing. Secure tub /shower unit upstairs at ea. stud. Page 1 of 4 8/23/99 Activities for Case #: MST98 -00294 • 1:15:25 PM • Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA723 Electrical Service • 2/4/99 BRP PASS CD 2/5/99 • MSTA724 Electrical Rough In 2/4/99 BRP PASS CD 2/5/99 use permanent ink or type on panel scedule - check ground . 'clamp on final MSTA725 Framing Insp DLH 7/8/98 MSTA726 Shear Wall Insp 12/17/98 . RB FAIL J'H 12/18/98 a) Block and nail exterior sheathing. b) Secure straps to • exterior sheathing. c) At • cantilever; add straps and LS50 brackets at 32 -inch centers. d) • . Nail floor decking into cantilever blocking 6- inches OC. e) Nail exterior sheathing where missed. MSTA728 Low Voltage 2/4/99 BRP PASS CD 2/5/99 . MSTA735 Gas Line Insp 2/10/99 KS PASS KBS 2/11/99 # gas pipnig pt test = 13.5 • - psi for 15 minutes (tag) • . #344122 MSTA740 Insulation Insp 2/26/99 KS PART KBS 3/1/99 #-1- under floor not insulated @ . this time MSTA752 Rain drain Insp 9/11/98 RB PART RB 9/11/98 34 % slope- needs inspection at/or before framing. Partially covered !!! Unable to view .entire system- by appearance, adequately installed where able to view. MSTA761 Water Service Insp 9/11/98 RB PART RB 9/11/98 Test at Top -out. Seal thru hole penetration at foundation. • MSTA765 Appr /Sdwlk Insp 4/16/99 MH PART AKJ 4/18/99 1) Install weep hole pipe at all existing cut outs . 2) Remove debris off the fire truck turn around. Not a stockpile spot. MSTA790 Electrical Final 7/9/99 BRP PASS AKJ 7/11/99 MSTA795 Mechanical Final 7/23/99 RB FAIL AKJ 7/26/99 see bldg final 7/23/99 MSTA797 Plumb Final 7/21/99 MS• PASS • AKJ 7/21/99 fixtures need caulking • MSTA799 Building Final 7/23/99 DONE AKJ 7/25/99 Prior to a final inspection, contractor shall install a 15 foot long section of perforated drain pipe in the utility trench to coleect seepage. The collected water should be then . hardpipied to the creek or storm sewer. See Report on file with address. Also talk with Mike • • White about this. Bob P - 3/2/99 MSTA080 (F) Ready to issue 7/24/98 JSD PASS JSD 7/24/98 Page2of4 • • 8/23/99 Activities for Case #: MST98 -00294 . . 1:15:25 PM • Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA092 (F) Issue combination permit 7/29/98 DEB DONE DRA 7/29/98 MSTA095 Issue plumbing signature form 8/4/98 JMT RECD JT 8/4/98 MSTA097 Issue electric signature form 8/6/98 JMT RECD JT 8/6/98 • MSTA706 Foundation Insp 8/31/98 KS PASS J'H 8/31/98 1. Ufer rod tagged. 2. Will add fdn vents at pony wall of suspended garage floor. 3. Building, will submit revisions to bldg. dept. (change of isolated piers at garage floor system) to _ continuous ftg also needs to specify spacing of studs and • size. 4. Install anchor bolts size and spacing as shown. MSTA714 Footing /Foundation Drain 9/11/98 RB PASS RB '9/11/98 INTERIOR AND EXTERIOR !!! • Already covered ! By appearance and review, the • system in part; which is • uncovered, appears to be • adequately installed and in accordance with approved • - plans and engineering. MSTA761 Water Service Insp 9/11/98 RB 9/11/98 MSTA717 PLM /Underfloor 9/11/98 1/21/99 RB PART RB 1/25/99 Support underneath 3 -inch waste for powder room W /C. MSTA711 Post/Beam Mechanical 9/11/98 RB 9/11/98 • MSTA726 Shear Wall Insp 1/13/99 RC FAIL ROC 1/13/99 NO PLANS ON SITE • MSTA726 Shear Wall Insp 1/14/99 RB PART RB 1/14/99 Report dtd. 12 -17 -98 RB Via. 1 -13 -99 RC, all issues completed EXCPET installation of LS -50 brackets at rear cantilever at 32 -inch centers. . ' OK TO VIEW AT FRAMING. MSTA726 Shear Wall Insp 2/17/99 RC FAIL ROC 2/17/99 LS50'S NOT INSTALLED AT CANTILEVER 3RD NOTICE MSTA726 Shear Wall Insp 2/17/99 , ROC 2/17/99 MSTA722 Plumb Top Out 2/17/99 2/22/99 RB PASS RB 2/23/99 MSTA722 Plumb Top Out 2/17/99 ROC 2117/99 MSTA722 Plumb Top Out 2/17/99 RC FAIL ROC 2/17/99 CORRECTION FOR . STRUCTURAL NOT • COMPLETE 2ND NOTICE Page 3 of 4 • • 8/23/99 Activities for Case #: MST98 -00294 1:15:25 PM • Assigned Hold • Updated • Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA725 Framing Insp 2/17/99 RC FAIL ROC 2/17/99 SEE SHEAR AND PLUMB THIS DATE 1. PROVIDE ATTIC ACCESS TO ALL . AREAS 30 " IN HEIGHT 2. REPAIR FLOOR JOIST WHRE • OVERBORED FOR . PLUMBING 3. PROVIDE PROOF OF INSUL IN CANTILEVER MSTA720 Mechanical Insp 2/17/99 RC FAIL ROC 2/17/99 FILL ALL HOLES IN RETURN AIR PLENUM MSTA720 Mechanical Insp 2/22/99 RB PASS RB 2/23/99 As per RC report dtd. 2- 17 -99: "' MSTA725 Framing Insp 2/22/99 RB PASS RB 2/23/99 As per RC report dtd. 2- 17 -99. . OK to insulate! MSTA726 Shear Wall Insp 2/22/99 RB PASS RB 2/23/99 As per RC report dtd. 2- 17 -99. OK to insulate! MSTA725 Framing Insp • 2/26/99 KS PASS KBS 3/1/99 #-1- approved per RC . correction list dated 2/16/99 MSTA720 Mechanical Insp - - 2/26/99 KS PASS KBS 3/1/99 #-1- approved per RC correction list dated 2/16/99 MSTA765 Appr /Sdwlk Insp 7/25/99 7/25/99 7/23/99 MW PASS No Hold AKJ 7/25/99 RDP note (bldg final 3/2/99) condition met MSTA799 Building Final 7/26/99 7/26/99 7/23/99 RB FAIL No Hold AKJ 7/26/99 1) slope grade away from . house on each side, maintain . min 6" earth /wood sep. 2) remove debris from crawl ' 3) reinstall vent hood at water heater provide sep. from hood and flex water line 4) cover exposed metal duct • with insul at both underflr - - locations where duct comes thru wall MSTA740 Insulation Insp 7/26/99 7/26/99 7/26/99 RB PASS No Hold AKJ 7/26/99 • MSTA799 Building Final 7/26/99 7/26/99 7/26/99 RB PASS No Hold AKJ 7/26/99 MSTA752 Rain drain Insp 7/26/99 7/26/99 7/26/99 RB PASS No Hold AKJ 7/26/99 • MSTA711 Post/Beam Mechanical 7/26/99 7/26/99 7/26/99 RB PASS No Hold • AKJ 7/26/99 MSTA795 Mechanical Final • 7/26/99 7/26/99 7/26/99 RB • PASS No Hold AKJ 7/26/99 MSTA960 (F) Issue Cert. of Occupancy 7/26/99 TIG RB DONE . No Hold JMT 8/23/99 Page 4 of 4 . CITY OF TIGARD BUILDING INSPECTION DIVISION MST ci. ---OZ9 24 -Hour Inspection Line: 639 -4175 Business Line: 639-4 1 BUP Date Requested "7- 7 ji � AM I M BLD Location 1 20q(5 S411 Y \/j ) Suite MEC Contact Person OA 4- Ph (OW) '31 ID PLM Contractor Ph SWR Yt1D�f1S T ` - Tenant/Owner ELC etat ni T ng Wall ELR Footing N 1,,..4"1-1:1L; T a FP Ftg Drain S Foundation A ‹*; sj x l�Nc ''y<f 1-j �.�'� ���- t• n. r= V.•. j.' air 1 , Crawl Drain Inspection Notes: SGN Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing L / . . s — � a w (�r�5 ail ing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: SS ART FAIL ING • Post & Beam Under Slab Top Out Water Service Sanitary Sewer rai PART FAIL Trf 196 155 Gas Line Smoke Dampers PART FAIL TRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE • Backfill/Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk C G Other Date �/ q ! `I Inspector Ext Final - PASS PART FAIL - DO NOT REMOVE this inspection record from the job site.