Specifications LBUY' cro3I FC g 5t'j 5111+(riljL S � 9407 S.W. Nimbus Avenue �p�eX Beaverton, OR 97008 fl Sales (503) 520 -1659 Service (503) 520 -8929 Fax (503) 643 -3219 PROJECT: DURHAM ELEMENTARY SCHOOL EQUIPMENT LIST PRODUCT ID DESCRIPTION 4002 -8001 FIRE ALARM CONTROL PANEL 4009 -9001 SIGNAL POWER EXTENDER 2098 -9201 SMOKE DETECTOR 2098 -9211 BASE 2098 -9649. DUCT HOUSING 2098 -9201 SMOKE DETECTOR 4098 -9402 HEAT DETECTOR 2099 -9754 MANUAL PULL STATION 4904 -9137 STROBE 4903 -9219 HORN /STROBE • Corporate Headquarters Simplex Plaza Gardner, MA 01441 -0001 U.S.A. (508) 632 -2500 Adv -0294.Fq'd , Q �o � I\1r DURHAM - 1672 I - FIRE ALARM SYSTEM SECTION 16721 - FIRE ALARM SYSTEM 1.0 GENERAL 1.1 CONTRACT CONDITIONS The Drawings. General Provisions of the Contract. Division 1 and 2, and Special Conditions of the Specification Sections apply to this section. 1.2 SCOPE • Furnish and install a complete fire alarm detection system incorporating new and existing devices. Provide new analog addressable system and devices at new and existing areas. Base Bid: • Expand existing fire alarm panel and connect new devices as shown on the Drawings. Provide items shown on Drawings and listed herein. Remove and reinstall existing fire alarm bells with strobe visual devices as shown on the Drawings. Provide audible /visual power extender as required and install in janitors closet. Provide one remote LED for each mechanical unit pair of duct detectors. Alternate Number 4: toA Provide items shown on Drawings and listed herein as Alternate Number 4. Replace existing panel and initiation circuits with new addressable devices. Each initiation device shall have a separate address. Delete remote LED's shown on Drawings and specified herein. 1.3 RELATED SECTIONS Fire Protection System - Section 13500. General Electrical Provisions - Section 16010. Basic Electrical Materials and Methods - Section 16050. Section 16120: Conductors and Connectors. 1.4 REFERENCES NFPA 72A - Installation. Maintenance, and Use of Local Protective Signaling System for Guard's Tour, Fire Alarm, and Supervisory Service. NFPA 72B - Installation, Maintenance, and Use of Auxiliary Protective Signaling System for Fire Alarm Service. NFPA 72C - Installation, Maintenance, and Use of Remote Station Protective Signaling System: NFPA 72E - Automatic Fire Detectors. NFPA 72G - Notification Appliances for Protective Signaling Systems. NFPA 72H - Guide for Test Procedures for Protective Signaling Systems. NFPA 101 - Life Safety Code. • 1.5 REGULATORY REQUIREMENTS System: UL and FM listed. Conform to requirements of NFPA 101. Uniform Building Code. National Electrical Code. NFPA Standard 72, dated 1993. Local Codes and Authorities having jurisdiction. Zoning and annunciation shall comply with fire Marshall requirements. ADA requirements. 16721 -1 o :l DURHAM - 16721 - FIRE ALARM SYSTEM 1.6 SYSTEM DESCRIPTION The existing system uses closed loop initiating device circuits with individual zone supervision, individual indicating appliance circuit supervision, incoming and standby power supervision. Included in this system is the control panel. manual-pull stations, automatic fire detectors. and indicating bells. Provide new hardwired devices, wiring, connections to devices, outlet boxes, junction boxes, and all other necessary material for a complete operating system which are connected and supervised from the existing fire alarm system. Alternate Number 4 will include all work associated with the installation of a new analog addressable fire alarm panel, addressable devices. wiring, connections to devices, outlet boxes, junction boxes, and all other necessary material for a complete operating system. All panels and peripheral devices shall be the standard product of a single manufacturer and shall display the manufacturer's name on each component. The catalog numbers specified under this section are those of Simplex Time Recorder Co., unless indicated otherwise, and constitute the type, product quality, material, and desired operating features. � i2= # �•z' /�,. t. . Acceptable manufacturers: Simplex Time Recorder Co., Faraday. Gamewell, Fire Control Instruments (FCI), Cerberus Pyrotronics, or approved. 1.7 OPERATION All doors normally held open by door control devices shall release upon AC power failure. The system alarm operation subsequent to the alarm activation of any manual station, automatic detection device, or sprinkler switch shall be as follows: All audible alarm indicating appliances shall sound a uniform code 3 temporal pattern until silenced by the alarm silence switch at the Control Panel. The temporal pattern shall consist of any appropriate sound, keyed 1/2 to 1 second "on ". 1/2 to 1 second "off', 1/2 to 1 second "on ", 1/2 second "off', 1/2 to I second "on" and 2 1/2 seconds "off' with timing tolerances of + 25% repeated for not less than 3 minutes. All doors normally held open by door control devices shall release. A supervised signal to notify the local fire department or an approved central station shall be activated. To accommodate and facilitate job site changes the type of "city connection circuit" shall be on site configurable to provide either a "reverse polarity ". "local energy ", "shunt" or dry contact connection. The mechanical controls shall activate the air handling systems per life safety specification, NFPA 101. The associated initiating device circuit red LED shall flash on the control panel and the remote annunciator until the alarm has been silenced at the control panel (or the remote annunciator). Once silenced, this same LED shall latch on. A subsequent alarm received from another zone after silencing shall flash the subsequent zone alarm LED on the control panel. The activation of any system smoke detector shall initiate an alarm verification operation whereby the panel will reset the activated detector and wait for a second alarm activation. If. within one (1) minute after resetting, a second alarm is reported from the same or any other smoke detector, the system shall process the alarm as described previously. If no second alarm occurs within one minute the system shall resume normal operation. The alarm verification shall operate only on smoke detector alarms. Other activated initiating devices shall be processed immediately. The actuation of the program "Test Set -up" switch at the control panel shall activate the "Walk Test" mode of the system which shall cause the following to occur: The city connection circuit shall be disconnected. Control relay functions shall be bypassed. The control panel shall show a trouble condition. The alarm activation of any initiation device shall cause the audible signals to pulse one round of code identifying the initiation circuit (e.g.: an activated smoke detector connected to Zone 4 shall pulse the audible signals 4 times in rapid succession). The panel shall automatically reset itself after code is complete. Any momentary opening of an initiating or indicating appliance circuit wiring shall cause the audible signals to sound for 4 seconds to indicate the trouble condition. \. 16721 -2 4 DURHAM - 1672 I - FIRE ALARM SYSTEM • 1.8 SUPERVISION The existing system contains nine (9) (Class B Style B) zones. Independently supervised initiation circuits so that a fault in any one zone shall not affect any other zone. The alarm activation of any initiation circuit shall not prevent the subsequent alarm operation of any other initiation circuit. Provide seventeen (17) additional (Class B Style B) zones to existing fire alarm panel as shown on the Drawings. 1.9 ALTERNATE NUMBER 4 - SUPERVISION Provide a new analog addressable panel and addressable initiation devices for new and existing areas. Replace existing panel and devices with new panel and devices installed at previous locations. There shall be (2) two independently supervised and independently fused indicating appliance circuits for alarm (horns) (bells) (chimes) (and flashing alarm lamps). Disarrangement conditions of any circuit shall not affect the operation of other circuits. All auxiliary manual controls shall be supervised so that all switches must be returned to the normal automatic position to clear system trouble. Each independently supervised circuit shall include a discrete amber "Trouble" LED to indicate disarrangement conditions per circuit. The incoming power to the system shall be supervised so that any power failure must be audibly and visually indicated at the control panel. A green "Power on" LED shall be displayed continuously while incoming power is present. The system batteries shall be supervised so that a low battery condition or disconnection of the battery shall be audibly and visually indicated at the Control Panel. The system expansion modules connected by ribbon cables shall be supervised for module placement. Should a module become disconnected from the C.P.U. the system trouble signal must sound. 1.10 POWER REQUIREMENTS The system shall be provided with sufficient battery capacity to operate the entire system upon loss of normal 120 VAC power in a normal supervisory mode for a period of twenty-four (24) hours with five (5) minutes of alarm operation at the end of this period. The system shall automatically transfer to the standby batteries upon power failure. All battery charging and recharging operations shall be automatic. All circuits requiring system operating power shall be 24 VDC and shall be individually fused at the control panel. 1.11 ALTERNATE NUMBER 4 - POWER REQUIREMENTS Extend existing panel 120 VAC power as required. The ■vem shall be provided with sufficient battery capacity to operate the entire system upon loss of normal 120 VAC power in a normal supervisory mode for a period of twenty -four (24) hours with five (5) minutes of alarm operation at the end of this period. The system shall automatically transfer to the standby batteries upon power failure. All battery charging and recharging operations shall be automatic. All circuits requiring system operating power shall be 24 VDC and shall be individually fused at the control panel. 1.12 QUALIFICATIONS Manufacturer: Company specializing in smoke detection and fire alarm systems with five (5) years documented experience. Installer: Company specializing in fire alarm with five (5) years documented experience. • 1.13 SUBMITTALS `f Submit product data. Provide wiring diagrams. data sheets. and equipment ratings, layout. dimensions, and finishes. A y Submit manufacturer's installation instructions. Submit manufacturer's certificate indicating system meets or exceeds specified requirements. 1.14 PROJECT RECORD DRAWINGS A Submit reproducible documents on Sepias and include location of end -of -line devices. and cable routing. Show all details legible and neat. 16721 -3 1 °1 a DURHAM - 16721 - FIRE ALARM SYSTEM 1.15 OPERATION AND MAINTENANCE DATA 4 Submit data. Include operating instructions, and maintenance and repair procedures. and parts list. 2.0 PRODUCTS 2.1 FIRE ALARM CONTROL PANEL The existing fire alarm panel is a Simplex type 4002 system. Modular construction with solid state, microprocessor based electronics. All visual indicators shall be high contrast, LED type. The existing control panel has the following features: 8 to 32 initiation device circuits. 2 alarm indicating appliance circuit. 9 supervised annunciator circuits. 1 (selectable) local energy, shunt master box, reverse polarity, remote station connection or dry contact. 4 max. Form C alarm contacts, fused (10 amps ea.). 2 min. 2 Form C alarm contacts (2.0 amps ea.). l min. Form C trouble contact (2.0 amps ea.). 1 earth ground supervision circuit. 1 basic 5 amp power supply. . • 1 expansion 5 amp power supply. 1 automatic battery charger. • 1 set of standby batteries. I lot resident non - volatile programmable operating system memory for all operating requirements. Provide the following features to the existing control panel: 17 Supervised Initiation Device Circuits. Additional battery capacity. 2.2 ALTERNATE NUMBER 4 - FIRE ALARM CONTROL PANEL FCI 7200 series analog/addressable Fire Alarm Control Panel. Modular construction with solid state, microprocessor based electronics. All visual indicators shall be high contrast, LED type and LCD display. The control panel shall contain the following features: Fifteen (15) two wire style 4 communication loops. 400 addressable analog points minimum. 2 alarm indicating appliance circuit. 500 event history log. Detector maintenance indicator describing when cleaning is necessary. Day /night sensitivity setting. 1 (selectable) local energy, shunt master box. reverse polarity, remote station connection or dry contact. 4 max. Form C alarm contacts. fused (10 amps ea.). 2 min. 2 Form C alarm contacts (2.0 amps ea.). 1 min. Form C trouble contact (2.0 amps ea.). 1 earth ground supervision circuit. 1 basic 5 amp power supply. 1 expansion 5 amp power supply. 1 automatic battery charger. I set standby batteries. 1 lot resident non - volatile programmable operating system memory for all operating requirements. 2.3 MANUAL STATIONS Single action constructed of high impact. red lexan with raised white lettering and a smooth high gloss finish. The break glass rod station shall have a hinged front with key lock. Stations which utilize screwdrivers. alien wrenches, or other commonly available tools shall not be accepted. Stations shall be keyed alike with the fire alarm control panel. When the station is operated. the handle shall lock in a protruding manner to facilitate quick visual identification of the activated station. Simplex type 2099 -9201 16721 -4 i 1 DURHAM - 16721 - FIRE ALARM SYSTEM 2.4 ALTERNATE NUMBER 4 - MANUAL STATIONS Semi -fush, red enamel finish, single action, four wire. Station to be keyed the same as the fire control panel. Addressed at time of installation via rotary switch assignment. FCI model MS- 6 /AMM -2. 2.5 PHOTOELECTRIC SMOKE DETECTORS U.L. standard 268 and shall be documented compatible with the control equipment to which it is connected. Detectors shall be listed for this purpose by Underwriters Laboratories Inc. The detectors shall obtain their • operating power from the fire alarm panel supervised detection loop. The operating voltage shall be 24 VDC (nominal). Removal of the detector head shall interrupt the supervisory circuit of the fire alarm detection loop and cause a trouble signal to be generated at the control panel. Each detector shall have a flashing status indicating LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady and at full brilliance. The detector may be reset by actuating the control panel reset switch. Simplex 2098 -9636. To minimize nuisance alarms. voltage and RF transient suppression techniques shall be employed as- well -as a smoke verification circuit and an insect screen. The detector design shall provide full solid -state construction and compatibility with other normally open fire alarm detection loop devices. (heat detectors, pull stations, etc.). The detector head shall be easily disassembled to facilitate cleaning. Remote LED alarm indicators shall be installed where indicated. 2.6 ALTERNATE NUMBER 4 - SMOKE DETECTORS Analog photoelectric smoke detector: L.E.D. light source, twist lock head. two wire base, and pulsing L.E.D. which lights steady to indicate alarm. It shall be possible to replace the smoke detector head without rewiring. Addressed at the time of installation via rotary switch assignment. FCI model ASD -P. Analog photoelectric smoke detectors shall provide for individual addressing of each detector. The sensor is constantly monitored to measure any change in its sensitivity due to the environment caused by dirt. aging. temperature. humidity, etc. It shall give an advanced indication to the FCID -A of the need for maintenance and i can be specific as to where the maintenance is needed. It is to be mounted on a two wire standard device base. FCI model ASD -P. • 2.7 AUTOMATIC HEAT DETECTORS Automatic heat detectors shall be combination rate -of rise and fixed - temperature type. When the fixed - temperature portion is activated. the units shall be non - restorable and give visual evidence of such operation. Heat detectors shall be Simplex type 2098 -9464 (135 degree F or 2098 -9465 194 degree F). 2.8 ALTERNATE NUMBER 4 - AUTOMATIC HEAT DETECTORS Analog thermal detector: dual thermistor sensing circuit, twist lock head, two wire base and pulsing L.E.D. which lights steady to indicate alarm. Addressed at the time of installation via rotary switch assignment. FCI model . ATD. • Analog thermal detectors consist of a dual thermistor sensing circuit for fast response. These sensors provide open area protection with fifty foot spacing. The sensors are continually monitored to measure any changes in their sensitivity due to temperature. It shall give an advanced indication to the FCID -A of the need for maintenance and can be specific as to where the maintenance is needed. It is to be mounted on a two wire standard device base. FCI model ATD. 2.9 FIRE ALARM BELLS The bells shall be polarized and shall be operated by 24 VDC. Each be bslt assembly shall include separate wire leads for in/out wiring for each leg of the associated signal circuit. T- p of gnat device conductors onductors to signal circuit conductors shall NOT be accepted. Bells shat b1tin'ty n yith.a minimum sound pressure level output of 90 dB at 10 feet. Bells sha l be 6 inch dia . finished•in"baked -on red enamel paint and be UL listed for fire alarm use. Bells shall be sot - s trface semi -flush mounting and be suitable for use within combination audiovisual units. Simplex type 2901 -9332 Provide visual strobe deVi ec s. Simplex type 4904 mounted on type 4905 -9921 modular adapter plate as shown on ( the Drawings. 16721 -5 . DURHAM - 16721 - FIRE ALARM SYSTEM 2.10 ALTERNATE NUMBER 4 - FIRE ALARM BELLS The bells shall be polarized and shall be operated by 24 VDC. Each bell assembly shall include separate wire leads for in/out wiring for each leg of the associated signal circuit. T- tapping of signal device conductors to signal circuit conductors shall NOT be accepted. Bells shall be vibrating type with a minimum sound pressure level output of 90 dB at 10 feet. Bells shall be 6 inch diameter, finished in baked -on red enamel paint and be UL listed for fire alarm use. Bells shall be suitable for surface or semi -flush mounting and be suitable for use within combination audio/visual units. FCI model BL with strobe plate. Provide visual strobe devices as shown on the Drawings. • 2.11 WATERFLOW SWITCHES Waterflow switches shall be provided and installed by others. Electrical contractor to provide connection to fire alarm system. 2.12 ALTERNATE NUMBER 4 - WATERFLOW SWITCHES Waterflow switches shall be provided and installed by others. Electrical contractor to provide connection to fire alarm system. Provide addressable monitor and configure with unique address at the time of installation. 2.13 DOOR HOLDERS ' Provid installed -byothefs. • 2.14 DUCT SMOKE DETECTORS ' Provide photoelectric duct smoke detector for installation from Division 15. Twist -in type detector head. Detectors shall operate on the light- scattering. photodiode principle: To minimize nuisance alarms. detectors shall have an • insect screen and be designed to ignore invisible airborne particles or smoke densities that are below the factory -set . alarm point. No radioactive material shall be used. Provide two (2) sets of normally open (N.O.) auxiliary ( contacts. Simplex type 2098 -9649 duct housing and 2098 -9201 detector. I Provide 24 VDC power from Fire Alarm Panel and monitor dry contacts on duct detectors for alarm. Fan shut down wiring shall be by Division 15. i Provide remote alarm LED indicator and mount at mechanical penthouse entrance. Simplex type 2098 -9808. 2.15 FIRE ALARM WIRE AND CABLE ti Cable shall be 2 conductor 18 AWG shielded Environmental Air Plenum wire and meet manufacturer .14''' specifications. West Penn or approved. 2.16 ALTERNATE NUMBER 4 - FIRE ALARM WIRE AND CABLE Cable shall be 2 conductor 16 AWG non - shielded Environmental Air Plenum wire and meet manufacturer specifications. West Penn or approved. 2.17 ALTERNATE NUMBER 4 - COMMUNICATION CIRCUIT FAULT MODULE Fault indicator module is provided to protect the system against wire -to -wire short circuits on the communication loops. The modules should be spaced between groups of sensors in a loop to protect the balance of the devices. In the event of a short circuit, the fault isolator shall provide protection for the communication circuit prior to its position of the loop. FCI model M500X. \, 2.18 ALTERNATE NUMBER 4 - ANNUNCIATORS Printer shall be a dot matrix. 80 column. Each alarm/trouble condition shall print in English the alarm/trouble \` type, location, time, and date. Printer shall connect via the RS232 port. Printer is to be supervised for proper X. operation. FCI model FC -PTR. 1A -12 SECTION 16721 - FIRE ALARM SYSTEM a. 2.13 DOOR HOLDERS Change first paragraph to read: install and provide power wiring for door holder furnished by Division 8." b. 3.1 INSTALLATION 16721 -6 Add "Connect complete flow switch to fire sprinkler bell." • DURHAM - 16721 - FIRE ALARM SYSTEM 2.19 ADDRESSABLE MONITOR Addressable monitor modules shall provide an address for a single. normally open initiating device such as a waterflow switch, manual station. etc. The monitor module shall be UL approved to extend the sensor loop to lengths up to 2.500 feet. Addressed via rotary switch. FCI model AMM -2. • 2.20 AUDIBLE /VISUAL POWER EXTENDER Signal circuit expander power supply shall contain .4 signal circuits, with 8 amperes signal output power with stand -by battery. Simplex model 4009 -9001. 3.0 EXECUTION 3.1 INSTALLATION Install system in accordance with manufacturer's instructions. Make conduit and wiring connections to sprinkler flow switches, sprinkler valve tamper switches, fire protection system control panels, duct smoke detectors. All wiring shall be installed in strict compliance with all the provisions of NEC- Article 760A and C, Power - limited Fire Protective signaling Circuits. All junction boxes shall be sprayed red and labeled "FIRE ALARM ". Clean all dirt and debris from the inside and the outside of the fire alarni equipment. Connect door holders to fire alarm panel. \ Duct detectors shall generate a trouble signal without causing a general alarm. .? � 3.2 FIELD QUALITY CONTROL • , mot 2 est in accordance with NFPA 72H and local fire department requirements. 3.3 MANUFACTURER'S FIELD SERVICES Provide manufacturer's field services. Include services of certified technician to supervise installation, adjustments, final connections, and system testing. 3.4 FIRE ALARM WIRE AND CABLE COLOR CODE Provide fire alarm circuit conductors with color coded insulation, or use color coded tape at each conductor termination and in each junction box as follows: Power Branch Circuit Conductors: red. white. Initiating Device Circuit: red. Detector Power. Supply: Violet. Municipal Trip Circuit: Orange. • 3:5 ALTERNATE NUMBER 4 - ANALOG ADDRESS PROGRAMMING Each analog address shall he programmed for: Device description. Device location. Verification operation to minimize false alarms. Logic command set per if- and-or -count statements. Assigned to one of up to 30 walk test zones. Day sensor sensitivity set point. Night sensor sensitivity set point. Alarm panel indicating circuit #1. Alarm panel indicating circuit #2. Alarm municipal output. • Activate select AOM's by unit or groups. Activate select DDM outputs. END OF SECTION 16721 -7 I) . 2A -16 SECTION 16721 - FIRE ALARM SYSTEM a. 1.6 SYSTEM DESCRIPTION � Change last sentence to read: "Acceptable manufacturers for Alternate Number 4: Simplex Time Recorder Co., Faraday, Gamewell, Fire Control Instruments (FCI). b. 2.9 FIRE ALARM BELLS REVISE TO READ "FIRE ALARM AUDIO /VISUAL DEVICE" Delete first two paragraphs and insert: "Visual devices shall be Simplex type 4904 -9105 and audible devices shall be Simplex 2901 -9840. The horns shall be polarized and shall be operated by 24 VDC. Each audio device assembly shall include separate wire leads for in /out wiring for each leg of the associated signal circuit. T- tapping of signal device conductors to signal circuit conductors shall NOT be accepted. Finished shall be baked- on red enamel paint and be U.L. listed for fire alarm use. Audio devices shall be suitable for surface or semi -flush mounting and be suitable for use within combination audio /visual units. c. 3.1 INSTALLATION Insert the following sentences: "Replace existing fire alarm bells with audio /visual device as specified herein." ' Provide separate signal circuits for audio and visual devices.' ' Return all unused fire alarm equipment to the Owner.' •