Permit MASTER PERMIT CITY. OF TIGARD I PERMIT #: MST1999 -00387 C Yiyf DEVELOPMENT SERVICES r DATE ISSUED: 01/26/2000 `'` 13125 SW Hall Blvd., Tigard, OR 97223 (503)1; ' 5 ' 1 Al L . SITE ADDRESS: 11452 SW SHROPE CT PARCEL: 2S103AB -04500 SUBDIVISION: WALNUT GLEN ZONING: R -4.5 BLOCK: LOT: 003 JURISDICTION: TIG REMARKS: PATH I: New single family dwelling w /attached garage. BUILDING REISSUE: STORIES: 2 FLOOR AREAS REQUIRED SETBACKS REQUIRED CLASS OF WORK: NEW HEIGHT: 23 FIRST: 1,345 sf BASEMENT: sf LEFT: 5 SMOKE DETECTORS: Y TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 1,253 sf GARAGE: 641 sf FRONT: 20 PARKING SPACES : 2 TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: sf RIGHT: 5 VALUE: $ 196,845.46 OCCUPANCY GRP: R3 BDRM: 3 BATH: 3 TOTAL: sf REAR: 23 PLUMBING SINKS: 1 WATER CLOSETS: 3 WASHING MACH: 1 LAUNDRY TRAYS: 1 RAIN DRAIN: 100 TRAPS: LAVATORIES: 5 DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: 1 CATCH BASINS: TUB /SHOWERS: 2 GARBAGE DISP: 1 WATER HEATERS: 1 WATER LINES: 100 BCKFLW PREVNTR: 1 GREASE TRAPS: OTHER FIXTURES: MECHANICAL FUEL TYPES FURN < 100K: BOIL/CMP < 3HP: VENT FANS: 4 CLOTHES DRYER: 1 GAS FURN > =100K: 1 UNIT HEATERS: HOODS: 1 OTHER UNITS: 1 MAX INP: btu FLOOR FURNANCES: VENTS: WOODSTOVES: GAS OUTLETS: 1 ELECTRICAL RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS 1000 SF OR LESS: 1 0 - 200 amp: 0 - 200 amp: W /SVC OR FDR: 1 PUMP /IRRIGATION: PER INSPECTION: EA ADD'L 500SF: 5 201 • 400 amp: 201 - 400 amp: 1st W/O SVC /FDR: 00 SIGN /OUT LIN LT: PER HOUR: LIMITED ENERGY: 401 - 600 amp: . 401 - 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT: MANU HM/SVC /FDR: 601 • 1000 amp: 601 +amps- 1000v: MINOR LABEL: 1000+ amp/volt : PLAN REVIEW SECTION Reconnect only: >=4 RES UNITS: SVC /FDR> =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC: ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM: INTERCOM/PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVE SIGNL: GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR: HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS: Owner: Contractor: TOTAL FEES: $ 5,948.46 This permit is subject to the regulations contained in the RIVERSIDE HOMES RIVERSIDE HOMES 15455 NW GREENBRIER PKWY #140 15455 NW GREENBRIER PKW a Y Tigard other applicable ble lCode, State All work will b e done Specialty in lt Codes and BEAVERTON, OR 97006 SUITE 140 all o w b BEAVERTON, OR 97006 2115 accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if the work is suspended for more than 180 days. ATTENTION: Phone: Phone: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set Reg a: LIC 70065 forth in OAR 952 - 001 -0010 through 952 - 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503) 246 -1987. REQUIRED INSPECTIONS Erosion 844 -8444 Underfloor insulation Plumb Top Out Gas Line Insp Appr /Sdwlk Insp Building Final Footing Insp Crawl Drain /Backwater Electrical Service Gas Fireplace Electrical Final Foundation Insp Footing /Foundation Dr; Electrical Rough In Insulation Insp Mechanical Final Post/Beam Structural PLM /Underfloor Framing Insp Rain drain Insp Plumb Final Post/Beam Mechanical Mechanical Insp Shear Wall Insp Water Line Insp Final inspection Issued By : !I - `L Permittee Signature : 1 Call (503) 639 -4175 by 7:00 p.m. for an inspection needed the next business day ..:TY Or TIGARL Residential Building Permit Application Plan Check# # 3 •i 3125 HALL BLVD. New Construction Rec'd By Gii Date Rec'd /1-9 TIGARD, OR 97223 Single Family Detached Date to P.E. V 503 - 5394171 Date to DST F 503 - 684 -7297 Permit #m r/ t4o3&5z Print or Type Called nit y f y 4 a I o: yo A ,.. Incomplete or illegible applications will not be accepted Lot 3 sw,e.«frr- oaAc`S Name of Name Project 1 Job / � " Architect Mailing Address n " (1 - j / Address Site Address - I' L' 5 f 55i0 ` C fir r'O p`Q J. ' City /State Zip Phone Name -) , PP // t)l ti 3,�� 1 HO Tne,7) Name Owner Mailing Address I /-J f`j fn u) OrcfnJ )r P k�c;y 1t'y' E n E Mailing Address City/State Zip Phone g I Pcuier C;i&' /! (o (' -,,98(c City /State Zip Phone General Name Contractor ` -U'7 7 Q O (1)(I)1ZO Describe work New) Addition 0 Alteration 0 Repair 0 Mailing Address to be done: Prior to permit Additional Description of Work: issuance, a copy City /State Zip Phone of all licenses are required if Oregon Const. Cont. Board Exp. Date r PROJECT / -- c/ exPdiatabaseOT Lic.# � �(/ c`� ///7 l VALUATION $. / '` ' Mechanical N r ( NEW CONSTRUCTION ONLY: Sub- _/ cz..�c 5 i Ede_ Sq. Ft. House: Sq. Ft. Gara e Contractor '� � � (.p q J Prior to permit _ 1 d i B ` ^ � Indi the restricted energy installation by the electrical ph issuance, a copy �J i— subcontractor in the following areas of all licenses Pd oR Gj i 775._59/9 Restricted Audio /Stereo are required if Oregon Const. Cont. Board I Exp. uate . Energy System Alarms expired in COT „� /, rt v Installations Vacuum Irrigation database 1 /S25 - �� _ System System Plumbing (check all that Other: Sub- nor)7(,vt'Sf P L r ( Wi apply) Number of Units in Building Unit Number Designation Contractor Mailing Address J 9 g P,3,26 SiD (() u1 0.0Cuit s Has the Subdivision Plat recorded? N/A YES NO Prior to permit City /State Zip Phone issuance, a copy ' j 5 a y'7, 7 K 9 -A7'1 of all licenses are OreConst. Cont. Board Exp. Date required if Lic.# / expired in COT 350 V h I database Plumbing Lic. # Exp. Dat I hearby acknowledge that I have read this application, that the information given is correct, that I am the owner or authorized agent of the owner, and that plans submitted are in compliance with ' Name Oregon State laws. Electrical r\f Q.t l. ' l•c_CI-r (C Signature iwner /Ag > Date Sub- Mailing Address C % / J'f � /7UC -f !mot � /� Contractor S Contact FPer on Name Phone # br e ( /701 j LA Jocci fel-5 -1 0 C ige City /State Zip Phone Prior to permit issuance, a copy 1-O u g 8 7033 666-0 FOR OFFICE USE ONLY: of all licenses are Oregon Const. Cont. Board Exp. Date - p required if Lic.# Plat #: Map , n�2 expired in COT a� 14) 3 jia lQ I v / 5-- 70Z � J��ei _ /� " y � database Electrical Lic. # Exp. at ks: Zon _ ( I0 \ 6 i2 e/.9 Electrical Supervisor Lic. # Exp. ate a ng App f,ir val: Planning Approval: TIF: � - , r X6 is \dsts \forms\sfd - new.doc 11/20/98 I ■ 05/05/2000 Activities for Case #: MST1999 -00387 9:37:59 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To • Done By Disp. Level By Updated Notes MSTA005 Application received 11/09/1999 GEO RECD No Hold GEO 11/16/1999 MSTA008 Permit Created 11/16/1999 GEO DONE No Hold GEO 11/16/1999 MSTA010 Check for prcl. restrict. 11/16/1999 GEO DONE No Hold GEO 11/16/1999 MSTA012 Plans routed to Plans Examiner 11/09/1999 GEO SEND No Hold GEO 11/16/1999 MSTA026 Plans approved by Pln Examiner 11/18/1999 BT2 DONE No Hold BT2 11/18/1999 • MSTA030 Reviewed plans routed to DSTS 11/18/1999 BT2 DONE No Hold BT2 11/18/1999 MSTA700 Erosion 844 -8444 11/18/1999 11/18/1999 No Hold BT2 11/18/1999 MSTA705 Footing Insp 11/18/1999 11/18/1999 02/04/2000 ICS PASS No Hold AKJ 02/06/2000 MSTA706 Foundation Insp 11/18/1999 11/18/1999 02/04/2000 KS PASS No Hold AKJ 02/06/2000 MSTA710 Post/Beam Structural 11/18/1999 11/18/1999 02/16/2000 RB PASS No Hold AKJ 02/16/2000 1) extend all threads up to main floor level view at shear 2) remove wood debris MSTA711 Post/Beam Mechanical 11/18/1999 11/18/1999 02/16/2000 RB PASS No Hold AKJ 02/16/2000 repair dryer vent termination at found vent MSTA712 Underfloor insulation 11/18/1999 11/18/1999 No Hold • BT2 11/18/1999 MSTA713 Crawl Drain /Backwater valve 11/18/1999 11/18/1999 02/11/2000 MRS PASS No Hold AKJ 02/13/2000' MSTA714 Footing /Foundation Drain 11/18/1999 11/18/1999 • No Hold BT2 11/18/1999 MSTA717 PLM /Underfloor 11/18/1999 11/18/1999 02/16/2000 . RB PASS No Hold AKJ 02/16/2000 MSTA720 Mechanical Insp 11/18/1999 11/18/1999 03/08/2000 KS FAIL No Hold RB 03/09/2000 Incompleted • MSTA722 Plumb Top Out 11/18/1999 11/18/1999 03/07/2000 MRS PASS . No Hold AKJ 03/07/2000 MSTA723 Electrical Service 11/18/1999 11/18/1999 03/13/2000 CD PASS No Hold AKJ 03/13/2000 • MSTA724 Electrical Rough In 11/18/1999 11/18/1999 03/13/2000 CD PASS No Hold AKJ 03/13/2000 • • • Page 1 of.3 . 05/05/2000 Activities for Case #: MST1999 -00387 9:37:59 AM • Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA725 Framing Insp 11/18/1999 11/18/1999 03/15/2000 KBS FAIL • No Hold AKJ 03/15/2000 1) provide attic access at gar 2) nail king studs to glulam at . gar and pos Conn to plates 3) nail each side of triple fl joist at gar 4) provide full bearing at glulam at gar pony wall also bolt • bracket 5) double fl joist missed at fam room 6) provide bearing to grade at 4x12 header at fam room 7) add fl joist at kitchen over . • notched • 8) full bearing under header at kitchen extend to grade 9) exhaust ducts vented at eave vent needs boot and seale 10) provide install manual for fireplace • 11) gas test ok MSTA726 Shear Wall Insp 11/18/1999 11/18/1999 03/03/2000 KBS FAIL No Hold AKJ 03/05/2000 incomplete • MSTA735 Gas Line Insp 11/18/1999 11/18/1999 03/08/2000 KS FAIL No Hold RB 03/09/2000 Incompleted. MSTA736 Gas Fireplace • No Hold BT2 11/18/1999 MSTA740 Insulation Insp 11/18/1999 11/18/1999 03/20/2000 KBS FAIL No Hold AKJ 03/20/2000 MSTA752 Rain drain Insp 11/18/1999 11/18/1999 02/11/2000 MRS PASS No Hold AKJ 02/13/2000 MSTA760 Water Line Insp 11/18/1999 11/18/1999 02/11/2000 MRS PASS No Hold AKJ 02/13/2000 MSTA765 Appr /Sdwlk Insp 11/18/1999 11/18/1999 No Hold AKJ 05/01/2000 private drive MSTA790 Electrical Final 11/18/1999 11/18/1999 04/27/2000 • TLP PASS No Hold AKJ 04/27/2000 MSTA795 Mechanical Final 11/18/1999 11/18/1999 04/28/2000 RB PASS No Hold RB 04/28/2000 • MSTA797 Plumb Final 11/18/1999 11/18/1999 04/28/2000 MRS FAIL No Hold AKJ 04/30/2000 no hot water MSTA798 Final inspection 11/18/1999 11/18/1999 No Hold BT2 11/18/1999 • MSTA799 Building Final 11/18/1999 11/18/1999 04/28/2000 RB FAIL No Hold • RB 04/28/2000 NOTE: Private drive. • 1. Protect beam brackets in garage. 2. Plumbing approval req'd 3. Remove all debris from • crawl space. MSTA080 (F) Ready to issue 11/19/1999 KJP DONE No Hold KJP 11/19/1999 MSTA092 (F) Issue combination permit 01/26/2000 GEO DONE No Hold GEO 01/26/2000 . MSTA095 Issue plumbing signature form • 01/26/2000 GEO VOID No Hold JMT 02/14/2000 change in contractors 2/14/00 Page 2 of 3 05/05/2000 Activities for Case #: MST1999 -00387 9:37:59 AM • Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA097 Issue electric signature form 01/31/2000 SLT RECD No Hold ST 01/31/2000 MSTA095 Issue plumbing signature form 02/15/2000 JMT RECD No Hold JMT 02/15/2000 change in contractors faxed to 639 -0498 MSTA726 Shear Wall Insp 03/06/2000 KS PASS No Hold AKJ 03/06/2000 add stud each side of hd at gar wall MSTA720 Mechanical lnsp 03/10/2000 KBS FAIL No Hold AKJ 03/12/2000 1) conn exhaust fans at upper level • 2) wall around b vent at upper 3) felt touching b vent 4) insul heat duct at attic 5) pressure drop at gas piping MSTA735 Gas Insp 03/10/2000 KBS • FAIL No Hold AKJ 03/12/2000 see mech insp 3/10 MSTA720 Mechanical lnsp 03/15/2000 KBS FAIL No Hold AKJ 03/15/2000 see framing 3/15 MSTA735 Gas Line Insp 03/15/2000 KBS PASS No Hold AKJ 03/15/2000 MSTA725 Framing lnsp 03/16/2000 GW FAIL No Hold AKJ 03/16/2000 1) double floor joist missing at fam room 2) add joist at kitchen where ovemotched MSTA720 Mechanical Insp 03/16/2000 GW . PASS No Hold AKJ 03/16/2000 • MSTA725 Framing Insp 03/20/2000 KBS PASS No Hold AKJ 03/20/2000 • MSTA700 Erosion 844 -8444 PASS No Hold RB 04/28/2000 Approved 4 -26 -00 CPB MSTA797 Plumb Final 05/01/2000 RB PASS No Hold AKJ 05/01/2000 MSTA799 Building Final 05/01/2000 RB PART No Hold AKJ 05/01/2000 1) protect gar beam brackets report dated 4/28 issues incomplete MSTA799 Building Final • 05/02/2000 RB FAIL No Hold AKJ 05/02/2000 3rd insp re: protection of gar beam brackets, which supports . the beams of bearing members. reinspect fee assessed MSTA780 «REINSPECTION» 05/02/2000 RB DUE No Hold AKJ 05/02/2000 3rd failed bldg final $50.00 MSTA050 Hold for 05/02/2000 AKJ DONE No Hold AKJ 05/02/2000 reinspect fee due MSTA797 Plumb Final . 05/02/2000 MRS PASS No Hold AKJ 05/02/2000 MSTA055 Hold Release to Issued 05/05/2000 JMT DONE No Hold JMT 05/05/2000 per Gary L., 3rd failed bldg final for exposed bracket should • have passed. remove hold. • Okay to process C /O. waive $50 reinspection fee MSTA960 (F) Issue Cert. of Occupancy 05/02/2000 RB DONE No Hold JMT 05/05/2000 • Page3of3 CITY OF TIGARD BUILDING INSPECTION DIVISION MST i ?9 24 Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested J AM PM BLD Location I S Suite MEC Contact Person Ph PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof aft AS PART FAIL MBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other D 512 �) k nS p 0 `� I ector I G S (e t� E Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. MASTER PERMIT CITY. OF TIGARD I PERMIT #: MST1999 -00387 C Yiyf DEVELOPMENT SERVICES r DATE ISSUED: 01/26/2000 `'` 13125 SW Hall Blvd., Tigard, OR 97223 (503)1; ' 5 ' 1 Al L . SITE ADDRESS: 11452 SW SHROPE CT PARCEL: 2S103AB -04500 SUBDIVISION: WALNUT GLEN ZONING: R -4.5 BLOCK: LOT: 003 JURISDICTION: TIG REMARKS: PATH I: New single family dwelling w /attached garage. BUILDING REISSUE: STORIES: 2 FLOOR AREAS REQUIRED SETBACKS REQUIRED CLASS OF WORK: NEW HEIGHT: 23 FIRST: 1,345 sf BASEMENT: sf LEFT: 5 SMOKE DETECTORS: Y TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 1,253 sf GARAGE: 641 sf FRONT: 20 PARKING SPACES : 2 TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: sf RIGHT: 5 VALUE: $ 196,845.46 OCCUPANCY GRP: R3 BDRM: 3 BATH: 3 TOTAL: sf REAR: 23 PLUMBING SINKS: 1 WATER CLOSETS: 3 WASHING MACH: 1 LAUNDRY TRAYS: 1 RAIN DRAIN: 100 TRAPS: LAVATORIES: 5 DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: 1 CATCH BASINS: TUB /SHOWERS: 2 GARBAGE DISP: 1 WATER HEATERS: 1 WATER LINES: 100 BCKFLW PREVNTR: 1 GREASE TRAPS: OTHER FIXTURES: MECHANICAL FUEL TYPES FURN < 100K: BOIL/CMP < 3HP: VENT FANS: 4 CLOTHES DRYER: 1 GAS FURN > =100K: 1 UNIT HEATERS: HOODS: 1 OTHER UNITS: 1 MAX INP: btu FLOOR FURNANCES: VENTS: WOODSTOVES: GAS OUTLETS: 1 ELECTRICAL RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS 1000 SF OR LESS: 1 0 - 200 amp: 0 - 200 amp: W /SVC OR FDR: 1 PUMP /IRRIGATION: PER INSPECTION: EA ADD'L 500SF: 5 201 • 400 amp: 201 - 400 amp: 1st W/O SVC /FDR: 00 SIGN /OUT LIN LT: PER HOUR: LIMITED ENERGY: 401 - 600 amp: . 401 - 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT: MANU HM/SVC /FDR: 601 • 1000 amp: 601 +amps- 1000v: MINOR LABEL: 1000+ amp/volt : PLAN REVIEW SECTION Reconnect only: >=4 RES UNITS: SVC /FDR> =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC: ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM: INTERCOM/PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVE SIGNL: GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR: HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS: Owner: Contractor: TOTAL FEES: $ 5,948.46 This permit is subject to the regulations contained in the RIVERSIDE HOMES RIVERSIDE HOMES 15455 NW GREENBRIER PKWY #140 15455 NW GREENBRIER PKW a Y Tigard other applicable ble lCode, State All work will b e done Specialty in lt Codes and BEAVERTON, OR 97006 SUITE 140 all o w b BEAVERTON, OR 97006 2115 accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if the work is suspended for more than 180 days. ATTENTION: Phone: Phone: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set Reg a: LIC 70065 forth in OAR 952 - 001 -0010 through 952 - 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503) 246 -1987. REQUIRED INSPECTIONS Erosion 844 -8444 Underfloor insulation Plumb Top Out Gas Line Insp Appr /Sdwlk Insp Building Final Footing Insp Crawl Drain /Backwater Electrical Service Gas Fireplace Electrical Final Foundation Insp Footing /Foundation Dr; Electrical Rough In Insulation Insp Mechanical Final Post/Beam Structural PLM /Underfloor Framing Insp Rain drain Insp Plumb Final Post/Beam Mechanical Mechanical Insp Shear Wall Insp Water Line Insp Final inspection Issued By : !I - `L Permittee Signature : 1 Call (503) 639 -4175 by 7:00 p.m. for an inspection needed the next business day