PERMIT ?ko a . o ...: h15T99 -0002
� DEVELOPMENT SERV6CES DATE ISSUED: 01/19/99
PARCEL: 1 S 135AD -05600
SITE ADDRESS...:10730 SW SITKA ST
SUBDIVISION -TRENT TERRACE ZONING: R -12
BLOCK LOT ^006 JURISDICTION: 7'i
Remarks: Path 1 - New SF dwelling.
- -- ______ - ___ ___ ____ ___ _______ --- ______ - - ___________ - BUILDING
REISSUE: STORIES : 2 FLOOR AREAS BASEMENT...: 0 sf REQUIRED SETBACKS - - -- REQUIRED---- -
CLASS OF WORK.:NEW HEIGHT • 21 FIRST • 716 sf GARAGE • 410 sf LEFT • 5 SMOKE DETECTRS: V
TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 633 sf FRONT • 20 PARKING SPACES: 2
TYPE OF CONST. :5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 7
OCCUPANCY GRP.:R3 BDRM: 3 BATH: 3 TOTAL - - - - -: 1349 sf VALUE..f: 101468 REAR • 16
- - - - - - -- PLUMBING -- - - - -- -
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 100 TRAPS • 0
LAVATORIES • 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 100 SF RAIN DRAINS: 1 CATCH BASINS..: 0
TUB /SHOWERS...: 2 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
----- - ---- — --- - -- — MECHANICAL -- -- - - - - --
FUEL TYPES - - - - -- FURN ( 100K ..: 1 BOIL /CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1
GAS FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES • 0 GAS OUTLETS...: 1
- — ELECTRICAL — - - - --
-- RESIDENTIAL UNIT - -- - -- SERVICE /FEEDER - - -- —TEMP SRVC /FEEDERS— -- BRANCH CIRCUITS -- - - -- MISCELLANEOUS - -- - -ADD'L INSPECTIONS -
15'i' SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
ER ADD'L 500SF.: 2 201 - 400 alp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0
LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT : 0
MANF HM /SVC /FDR: 0 601 - lv amp.: 0 601 +amps -1000 v: 0 MINOR LABEL -10: 0
1000+ amp /volt.: 0 - - -- - -- PLAN REVIEW SECTION
Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) 225 A.: ) 600 V NOMINAL: CLS AREA /SPC BCC:
ELECTRICAL - RESTRICTED ENERGY - --
A. SF RESIDENTIAL B. COMMERCIAL - - - - -- - -------- - - - --- - ---
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: DTH: .. BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICA! OTHR: ..
HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0
Owner: - Contractor: — -- TOTAL FEES:t 4847.26
KINCO PROPERTIES, LTD KIMCO PROPERTIES LTD This permit is subject to the regulations contained in the
22060 SE 442ND AVE 22060 SE 442ND AVE Tigard Municipal Code, State of Ore. Specialty Codes and all
SANDY OR 97055 SANDY OR 97055 other applicable laws. All work will be done in accordance
with approved plans. This permit will expire if work is
Phone #: 668 -7075 Phone #: 668 -7075 not started within 180 days of issuance, or if the work is
Reg #..: 110832 suspended for more than 180 days. ATTENTION: Oregon law
- -- — requires you to follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952- 001 -0080. You may obtain copies of these rules or
direct questions to OUNC by calling (503)246 -1987.
--- - - - - -- -------------------- - - - - -- REQUIRED INSPECTIONS ------ - - - - --
Erosion 844 -8444 Crawl Drain /Back Electrical Rough Insulation Insp Mechanical Final
Footing Insp PLM /Underfloor Framing Insp Rain drain Insp Plumb Final
Foundation Insp Mechanical Insp Shear Wall Insp Water Service In Building Final
Post /Beam Struct Plumb Top Out Low Volt Appr /Sdwlk Insp
Post /Beam Mechan Elect ' - - •vi► Gas Line In p Electrical Final cam,,,vv _ ' Issued By:- ' �� Per Signature:_ - A m id / / / . .
-- FA-+- F-- 7....;..{.- FA--I- A-- '+ V-+-F± -•F-J- -1--1- C- ±-I--:--:- F 4 .....--:-i•-F .- -FA -+ +•+ + +±+ 4--h-: r :--F-1 -F± 1-4-1-4 1 --F F F F+ 'I -:--1•-h
Call 639 -4175 by : :00 p.m. for an inspection needed the next bi ,iness day
L
\ / - / 72_
ITY OF IIGARD Residential Building Permit Application Plan Ch
13125 SW HALL BLVD. New Construction Rec'd B r
es Date Rec'd / - —
TIGARD, OR 97223 Single Family Detached Date to P.E. /Air"
V 503 - 639 -4171 Date to DST / - • - r1 y ,,r
F 503 - 684 -7297 / I Permit # / r99-00a.2,
Print or Type (V Called / - -7 r- 4.
Incomplete or illegible applications will not be accepted L6Fr VA7
awn 99-000.2,
Name of Project Ley(, 74 4r7744-
Job /1 F. / t/ S, :C/DA/J FgV✓ it
Architect Mailin Address
Address S ite Address ' • City /j 9 !,,, / /�G�iJ f 7OF
//c, ` j 3 SA) • s /TieX G6 /S_fate (f` ; v' Ziiip ll Phone L 3
Name /� p p /
/< /iV .!7 / i/�/ • Z, 1J, Name C��TG 0/1. 7z7S° d?97 - ' 7 l r,
Owner Mailing Address AQ �/ 0�Sl��J
°L Z Ole C7 5 19 �/ � Engineer Mailing Address
C ttate Zip Phone, 7 9
i I11 / g 77607 ( City/State Zip Phone
General Name
Contractor / /,' 'CO /9' 67D Describe work New Addition 0 Alteration 0 Repair 0
Mailing Address )/ �/ (. to be done:
Prior to permit 2 Z D G 01 5, ,� 77 - Ave • Additional Description of Work: 7 3 q . rG
issuance, a copy City /State Zip Phone 6, t �...- X1349' " 95, 930 60 .1/0 )r /I ) 7S/9�
of all licenses fi�` , r7 05-5- bt -7O7
are required if re gon �o fi st. Board Exp. Date PROJECT
expired in COT Lic. #
database I / 08 3Z / J / X0-99 , / VALUATION $ /o/ /5b . a/ dat
Mechanical ame NEW CONSTRUCTION ONLY:
Sub- . , r 1 -L •• , , , .A/ Sq. Sq. Ft. House: . Ft. Garage
ai in ddress 4 / a
C• 't g° �/ � //t/C. /3q S` tF
'rior t• ,, it � R 0, r , Indicate th'e restricted energy installatio by the electrical
iss an. r' . City /State Zip p . • subcontractor in the following areas
•f . J ses /1 9 7/.��_• , -- Z Restricted Audio /Stereo
re r '. uired i f Or: • on Const. Co :oa • Exp. Da = ..---- Energy System Alarms
expire. in COT ic.# � l6 /0-/Z-17 Installations Vacuum Irrigation
data. dSystem System
Plumbing Name
- (check all that Other:
Sub , 12 /" pia/Ng/ apply)
Contractor Mailing Address Number of Units in Building Unit Number Designation
1 ,/ /' /3 d)c KO • Has the Subdivision Plat recorded? N/A YES NO
Prior to permit ity/St to Zip Phone �
issuance, a copy CANA i a . 9 70/3 .2bG -/ /O
of all licenses are Oregon o t. Cont. Board Exp. Date /1�
required if Lic. # / / , n S� f - 09 W
expired in COT �`
database Plumbing Lic. # Exp. Da V?i) I hearby acknowledge that I have read this application, that the
3 4 (0 /01 information given is correct, that I am the owner or authorized agent
of the owner, and that p s submitted are in compliance with
Name Oregon Stag'
•
Electrical 40 4.9 t ecoic Si , tur- •fit', y a ent iDate p
Sub- Mailing Address 1 ! - 1 � 0
/- Conta . Person me Phone #
Contractor P.®. &>< b.6 /t J --J ir1/66a, , '�Y7 —
City/State 6 ,,,Zip Phone Aloe. eig,_ &0607 ( �/ / l
�
Prior to permit KK ,,�
issuance, a copy 4 /6.$ p7 ,7z7 6 s lo27 FOR OFFICE USE ONLY: \W-.0-
. 1 0 - / d
of all licenses are Oregon Const. Cont. Board Exp. Date
Plat #: Ma !TL #:
required if Lic.# p
expired in COT //.c395 2/94.4/`-. / -i/7 W /s /i'5r9 -a56o6
database Electrical L .2 Exp. Di9 Setbacks: Zone:
Electrical Supervisor Li # Exp. Date Engineering Approval: Planning Approval: TIF: /
/ f-3 75 _ / /J /`0 7: P. /z it /AM _ N/�
y39S 5
is \dsts \forms\sfd- new.doc 11/20/98
7/19/99 Activities for Case #: MST99 -00002
11:51:43 AM
I-
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
1 MSTA005 Application received 1/4/99 DEB RECD CTR 1/5/99
MSTA008
Permit Created 1/5/99 DLH DONE CTR 1/5/99
MSTA010 Check for prd. restrict. 1/5/99 DLH PASS DLH 1/5/99
MSTA012 Plans routed to Plans Examiner 1/5/99 DLH SENT DLH 1/5/99
1
i MSTA026 Plans approved by Pln Examiner 1/6/99 RT PASS BT2 1/6/99
MSTA030 Reviewed plans routed to DSTS 1/6/99 RT PASS BT2 1/6/99
MSTA032 DST Post - Review Completed 1/7/99 GEO DONE GEO 1/7/99
MSTA155 Development conditions met CTR 1/5/99
MSTA700 Erosion 844 -8444 CTR 1/5/99
MSTA705 Footing Insp 1/21/99 RC PASS ROC 1/22/99 UFER APP.
MSTA706 Foundation Insp 2/4/99 RB PART RB 2/5/99 Seismic restraint. Ventilation
req'mts. Anchor bolt req'mts.
MSTA710 Post/Beam Structural 2/22/99 RB FAIL RB 2/23/99 Plumbing issues. Mechanical
issues. Mud sill anchorage.
Crawl drain issue. Vapor barrier
• req'd at exposed areas of the
crawl surface.
MSTA711 Post/Beam Mechanical 2122/99 RB FAIL RB 2/23/99 Support flex off of ground AND
at 4' horizontal intervals. Vapor
barrier missed at metal duct -
protection of insulation wrap.
Make sure that the fumace
plenum box is insulated.
MSTA713 Crawl Drain /Backwater valve 2/10/99 MS PASS MRS 2/10/99
MSTA717 PLM /Underfloor 2/22/99 RB PART RB 2/23/99 Clean flux from copper water
lines. Insulate that part of the
water main BELOW floor
beams or insulation level.
Insulate low point drains. Was
water service tested? Was
Sewer Tested? YES 2 -16 -99
GS.
MSTA720 Mechanical Insp 5/24/99 KS FAIL AKJ 5/24/99 See framing notes
MSTA722 Plumb Top Out 4/30/99 GS PASS AKJ 5/2/99
MSTA723 Electrical Service 5/24/99 CD PASS AKJ 5/24/99 Be more specific on labeling for
lighting circuits 110 -22
MSTA724 Electrical Rough In 5/24/99 CD PASS AKJ 5/24/99
Page 1 of 3
C
7/19/99 Activities for Case #: MST99 -00002 t
11:51:43 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA725 Framing Insp 5/24/99 KS ' FAIL AKJ 5/24/99 1) add stud at plate splice at
entry
2) strap plates to glulam at
entry both sides
3) connect exhaust fans at half
bath
I 4) add support at stair jacks
5) nail truss Gips •
6) provide eave baffles between
vaulted ceiling and truss
7) secure insulation shield an
maintain clearance
8) fireblock tub /shower
9) add king stud at glulam at
tub bath and horizontal strap
10) complete interior shear
panels at garage front
11) soffits at garage not built
MSTA726 Shear Wall lnsp 5/24/99 KS FAIL AKJ 5/24/99 See framing notes
MSTA728 Low Voltage CTR 1/5/99 .
MSTA735 Gas Line Insp 5/20/99 KS PASS AKJ 5/20/99 Support gas piping 1/2" at 6'
intervals
MSTA740 Insulation Insp 5/27/99 KS PASS AKJ 5/27/99
MSTA752 Rain drain lnsp 2/10/99 MS PASS MRS 2/10/99
MSTA761 Water Service Insp 4/5/99 GS FAIL AKJ 4/5/99 0 pressure at guage
MSTA765 Appr /Sdwlk Insp 6/30/99 N/A AKJ 6/30/99 private rd
MSTA790 Electrical Final 7/1/99 CD PASS AKJ 7/1/99
MSTA795 Mechanical Final 7/1/99 KS FAIL AKJ 7/1/99 see bldg final notes
MSTA797 Plumb Final 7/1/99 MS FAIL AKJ 7/5/99 1) uncon at meter leaking
2) service to main valve leaking
MSTA799 Building Final 7/1/99 KS FAIL AKJ 7/1/99 need plm and elec finaled
MSTA080 (F) Ready to issue 1/7/99 GEO PASS GEO 1/7/99
MSTA092 (F) Issue combination permit 1/19/99 JSD PASS JSD 1/19/99
MSTA095 Issue plumbing signature form 2/5/99 VLN RECD VLN 2/5/99
MSTA097 Issue electric signature form 1/28/99 JMT VOID JT 3/5/99
MSTA752 Rain drain Insp 2/22/99 RB PART RB 2/23/99 Storm line to street- Cut in
• weep hole at curb. Clean out
back -water valve in crawl
space.
MSTA713 Crawl Drain /Backwater valve 2/22/99 RB PART RB 2/23/99 Clean out low point crawl drain
back -water valve.
MSTA710 Post/Beam Structural 3/2/99 RB PASS RB 3/2/99
Page 2 of 3
7/19/99 Activities for Case #: MST99 -00002 .
11:51:43 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA711 Post/Beam Mechanical 3/2/99 RB PASS RB 3/2/99
MSTA717 PLM /Underfloor 3/2/99 MS PASS MRS 3/2/99
MSTA097 Issue electric signature form 3/5/99 JMT RECD JT 3/5/99
MSTA095 Issue plumbing signature form 3/26/99 JMT RECD JT 3/26/99 change of contractor
I ,I
I MSTB781 Water Service Insp 4/20/99 4/20/99 4/20/99 GS PASS No Hold AKJ 4/20/99
MSTB751 Exterior Sheathing Insp 4/22/99 KS PASS No Hold AKJ 4/22/99
MSTA726 Shear Wall Insp 5/25/99 5/25/99 5/25/99 KS PASS No Hold AKJ 5/25/99
MSTA725 Framing Insp 5/25/99 5/25/99 5/25/99 KS PASS No Hold AKJ 5/25/99
MSTA720 Mechanical Insp 5/25/99 5/25/99 5/25/99 KS PASS No Hold AKJ 5/25/99
MSTA795 Mechanical Final 7/5/99 7/5/99 7/2/99 TLP PASS No Hold AKJ 7/5/99
MSTA797 Plumb Final 7/5/99 7/5/99 7/2/99 TLP PASS No Hold AKJ 7/5/99
MSTA799 Building Final 7/5/99 7/5/99 7/2/99 TLP FAIL No Hold AKJ 7/5/99 garage /house stairs run from
7.5" to 9 ". measure to top of
threshold 3/8" variance max
allowed.
cannot access underfloor crawl
• space, handle not installed on
access cover.
MSTA795 Mechanical Final 7/6/99 7/6/99 7/6/99 TLP PASS No Hold AKJ 7/6/99
MSTA799 Building Final 7/6/99 7/6/99 7/6/99 TLP PASS No Hold AKJ 7/6/99
MSTA000 SF Detached Menu -1 unit 7/6/99 TIG TLP DONE No Hold JMT 7/19/99
MSTA960 (F) Issue Cert. of Occupancy 7/6/99 TIG TIG DONE No Hold JMT 7/19/99
Page3of3 .
' CITY OF TIGARD BUILDING INSPECTION DIVISION DUG
24 -h;our Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested 7 /(0 / / AM Qf ) BLD
Location /O 73c S &i 5 Suite MEC
Contact Person Ph PLM
Contractor Ph SWR
DING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
` FAIL
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PA FAIL
HANICAL
os & Beau
Rough In
Gas Line
• e Dampers
(i-.
___ PART FAIL
• TRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
Fire Supply Line
ADA
Approach /Sidewalk 7/ Date Inspec / 4T''► ,p Ext
• Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST 9q-Z,
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
. BUP
Date Requested - / AM__X_PM BLD
Location ((f? Suite MEC
Contact Person ) I Ph FI -C PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler 4i A £ //L -
Fire Alarm
Susp'd Ceiling
Roof
Misc: 1/ Ifi / /�Lillm.
Final
PASS PART FAIL
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
PAS PART
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA 7 /
Approach/Sidewalk
Other `
Other Date Inspector Ext
Final
PASS PART FAIL DO OT REMOVE this inspection record from the job site.
CITY OF TIGARD MASTER PERMIT
; A
PERMIT ?ko a . o ...: h15T99 -0002
� DEVELOPMENT SERV6CES DATE ISSUED: 01/19/99
PARCEL: 1 S 135AD -05600
SITE ADDRESS...:10730 SW SITKA ST
SUBDIVISION -TRENT TERRACE ZONING: R -12
BLOCK LOT ^006 JURISDICTION: 7'i
Remarks: Path 1 - New SF dwelling.
- -- ______ - ___ ___ ____ ___ _______ --- ______ - - ___________ - BUILDING
REISSUE: STORIES : 2 FLOOR AREAS BASEMENT...: 0 sf REQUIRED SETBACKS - - -- REQUIRED---- -
CLASS OF WORK.:NEW HEIGHT • 21 FIRST • 716 sf GARAGE • 410 sf LEFT • 5 SMOKE DETECTRS: V
TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 633 sf FRONT • 20 PARKING SPACES: 2
TYPE OF CONST. :5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 7
OCCUPANCY GRP.:R3 BDRM: 3 BATH: 3 TOTAL - - - - -: 1349 sf VALUE..f: 101468 REAR • 16
- - - - - - -- PLUMBING -- - - - -- -
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 100 TRAPS • 0
LAVATORIES • 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 100 SF RAIN DRAINS: 1 CATCH BASINS..: 0
TUB /SHOWERS...: 2 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
----- - ---- — --- - -- — MECHANICAL -- -- - - - - --
FUEL TYPES - - - - -- FURN ( 100K ..: 1 BOIL /CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1
GAS FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES • 0 GAS OUTLETS...: 1
- — ELECTRICAL — - - - --
-- RESIDENTIAL UNIT - -- - -- SERVICE /FEEDER - - -- —TEMP SRVC /FEEDERS— -- BRANCH CIRCUITS -- - - -- MISCELLANEOUS - -- - -ADD'L INSPECTIONS -
15'i' SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
ER ADD'L 500SF.: 2 201 - 400 alp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0
LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT : 0
MANF HM /SVC /FDR: 0 601 - lv amp.: 0 601 +amps -1000 v: 0 MINOR LABEL -10: 0
1000+ amp /volt.: 0 - - -- - -- PLAN REVIEW SECTION
Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) 225 A.: ) 600 V NOMINAL: CLS AREA /SPC BCC:
ELECTRICAL - RESTRICTED ENERGY - --
A. SF RESIDENTIAL B. COMMERCIAL - - - - -- - -------- - - - --- - ---
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: DTH: .. BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICA! OTHR: ..
HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0
Owner: - Contractor: — -- TOTAL FEES:t 4847.26
KINCO PROPERTIES, LTD KIMCO PROPERTIES LTD This permit is subject to the regulations contained in the
22060 SE 442ND AVE 22060 SE 442ND AVE Tigard Municipal Code, State of Ore. Specialty Codes and all
SANDY OR 97055 SANDY OR 97055 other applicable laws. All work will be done in accordance
with approved plans. This permit will expire if work is
Phone #: 668 -7075 Phone #: 668 -7075 not started within 180 days of issuance, or if the work is
Reg #..: 110832 suspended for more than 180 days. ATTENTION: Oregon law
- -- — requires you to follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952- 001 -0080. You may obtain copies of these rules or
direct questions to OUNC by calling (503)246 -1987.
--- - - - - -- -------------------- - - - - -- REQUIRED INSPECTIONS ------ - - - - --
Erosion 844 -8444 Crawl Drain /Back Electrical Rough Insulation Insp Mechanical Final
Footing Insp PLM /Underfloor Framing Insp Rain drain Insp Plumb Final
Foundation Insp Mechanical Insp Shear Wall Insp Water Service In Building Final
Post /Beam Struct Plumb Top Out Low Volt Appr /Sdwlk Insp
Post /Beam Mechan Elect ' - - •vi► Gas Line In p Electrical Final cam,,,vv _ ' Issued By:- ' �� Per Signature:_ - A m id / / / . .
-- FA-+- F-- 7....;..{.- FA--I- A-- '+ V-+-F± -•F-J- -1--1- C- ±-I--:--:- F 4 .....--:-i•-F .- -FA -+ +•+ + +±+ 4--h-: r :--F-1 -F± 1-4-1-4 1 --F F F F+ 'I -:--1•-h
Call 639 -4175 by : :00 p.m. for an inspection needed the next bi ,iness day
L