Correspondence February 18, 2004 ka ' ' n '�n "Ilii'IP "�
CITY OF TIGARD
Dan Roach
Arrow Mechanical OREGON
10330 SW Tualatin Road
Tualatin, OR 97062
RE: MECHANICAL EQUIPMENT @ NEW YORK SUBS
Mechanical Permit: MEC2004 -00037 Construction Type: VN
Tenant Name: New York Subs Occupancy Type: B
Address: 9802 SW Shady Lane Occupant Load: 29
Area: NA Stories: 1
The plan review was performed under the State of Oregon Mechanical Specialty Code
(OMSC) 2002 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99-
01) 1999 edition. The submitted plans are approved subject to the following.
1. Ductwork shall be supported in accordance with Sheet Metal & Air Conditioning
Contractors National Association, Inc. (SMACNA)
2. Each appliance shall be provided with a shutoff valve separate from the appliance.
The shutoff valve shall be located in the same room and within six feet of the
appliance served. Access shall be provided to the shutoff valve. C409.5 OMSC
3. Appliances shall be accessible for inspection, service, repair or replacement without
removal of permanent construction. 306.1 OMSC
4. Appliances installed on roofs or elevated structures exceeding 16 feet in height shall
be provided with a permanent means of access grade or floor level. 306.5 OMSC
5. Manufacturer's installation instructions shall be available on the jobsite at the time of
inspection. 304.1 OMSC
6. Condensate from cooling coils or evaporators shall be collected and discharged to an
as • -d. •••• gfii..- ..dis.s are. i . 'M '
7. Guards shall be provided where appliances are located within 10 feet of the roof edge
or open side of a walking surface and such edge or open side is located more than 30
inches above the floor, roof or grade below. The guard shall be 42 inches above the
elevated surface with an intermediate rail so as not to allow the passage of a sphere
21 inches in diameter. 304.9
8. Equipment and appliances regulated by this code requiring electrical connections
shall have a positive means of disconnect in accordance with the Electrical Code.
301.7 OMSC
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall
u be maintained on the jobsite. The plans shall be available to the Building Division inspectors
throughout all phases of construction. 106.4.2 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new
buildings in such a position as to be plainly visible and legible from the street or road
fronting the property.
The following information is required prior to issuance of a Mechanical Permit.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and i rocessing the documents.
Respect ,
ria alock,
S . ' or Plans Examiner
rip !IF
February 12, 2004 , FEB 13 2004 _ . ,J 1
Ih/T =111 U irs 7i a T r r ' ARD
Dan Roach
Arrow Mechanical FEB 9GO 5
10330 SW Tualatin Road C� 4
Tualatin, OR 97062 _ SUILDI OF T /GARD
RE: MECHANICAL EQUIPMENT @ NEW YORK SUBS
Mechanical Permit: MEC2004 -00037 Construction Type: VN
Tenant Name: New York Subs Occupancy Type: B
Address: 9802 SW Shady Lane Occupant Load: 29
Area: NA Stories: 1
The plan review was performed under the State of Oregon Mechanical Specialty Code
(OMSC) 2002 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99-
01) 1999 edition. The following information is required prior to issuance of a Mechanical
Permit.
1. The roof framing indicated is existing trusses. Trusses are an engineered product.
Provide a structural analysis of the trusses to clarify the ability to support the load
from the new Mechanical unit. — A ttaLh ec/
2. Provide, if applicable, the weight and location of existing equipment supported on the
roof structure.. — 140/e- e vt ruS S es i w 8 ti es fiov)
3. The new unit appears to be within 10 feet of the edge of the building. Guards shall be
• provided where appliances are located within 10 feet of the roof edge or open side of
a walking surface and such edge or open side is located more than 30 inches above
the floor, roof or grade below. The guard shall be 42 inches above the elevated
surface with an intermediate rail so as not to allow the passage of a sphere, 21 inches
in diameter. 304.9 OMSC. Indicate location of guards on the plan.
4. Appliances installed on roofs or elevated structures exceeding 16 feet in height shall
be provided with a permanent means of access grade or floor level. 306.5 OMSC
Clarify roof height _ j 2 ia . Ra o C Uwe
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and pro ing the documents.
= LJe ciu:ILdeter .414 exact IocJi 4 O 4
Respect I St - to ivy tale 'etc! we .,v:t(s . io'away
Frost the edge op the b ENc, '4eeN
•
ianBl. S #9Fed e could p /ace t14;/• Ifei ;) 4e.te_ a h
Senior ' ..Examiner trk,S5 We- w *H fed 1
13125 SW Hall Blvd., Tigard OR 97223 (503) 639 -4171 1DD (503) 684 -2772
•
•
Site Address:
. . ..
.. . . , ., . .
. .. , .
..... .. '
.. .
4 111 1 Letter of Transmittal .
• -
2 i .
. Building Division
City of Tigard •
- DATE RECEWED:
TO: 33 vow St 01/41 oc-14
U
DEPT: BUILDING DIVISION
• .
, .
FROM: 1>ctai R Dec c-14 • 1,:.;, ...,..',-- - t - :,:.. :. .,
,... _....
COMPANY: Avhnou? 1$ I Feb; qn; cq I
"-- .
PHONE NO.: 5 S - C
S S s ' - 7 81 6 . By:
RE:
(Case number, site address, etc.)
New Yook ..c)):34
- (Project name or subdivision name and lot number)
. .
ATTACHED ARE TILE FOLLOWING ITEMS: •
' ',.,. .Cciiiioi:-
Additional set(s) of plans. Revisions:
Cross section(s) and details. Wall bracing and/or lateral analysis.,
Floor/roof framing. Basement and retaining walls.
.
• Beam calculations. 37 •00,c ' Engineer's calculations.
) re; e_._ Other (explain): co„ or x ,,,, /et-i-ev with "47 yeffign4ce6
REMARKS:
• .
. .
-- -. -- - - - -- - — - - - - - -_ --___
- ','. i ' :r:: - .:ihtS:::)::.•-; .- .., - -,',:.).:::;;; - : ,lij
..ROUteil,161Perinit'TeChniciii Oite'.:i-- :::'..•.., 7,- .,.:j,,. -. .... 4-: : . ::!;; , :', : '4'',.1 : -''S'Iii c itialit5- ; * -: :::::AW- r i:1,
T`Fie.i.Diii."•:.:, $ ?-...:,,,•. '•:' 040 .:::-.-..."':'.. 7. ..:'::'.,. - ;,:7-;:"f•.:.,' . 7.1.1iiiii.1: : . '
. . .
Reprint Permit OerPlans 'Biaiiiiii,611i:::' ," .-:-.I Yes: .. T . -: '--.'sz ..;-:
' . • _ Notifi6.d `',.:..;,':: • '......::-••.: .,''.• :: -.•:i
i:BuildingWonns\LetterTransmittaldoc 1/6/04
..._. ., .