Loading...
Permit C ITY OF TIGARD MECHANICAL PERMIT 4 DEVELOPMENT SERVICES PERMIT #: MEC2003 -00525 .4 ' � J I 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 8/28/03 PARCEL: 2S 112 DA -00800 SITE ADDRESS: 15115 SW SEQUOIA PKWY 150 SUBDIVISION: PACIFIC CORP. CENTER ZONING: I -P BLOCK: LOT: JURISDICTION: TIG CLASS OF WORK: NEW FLOOR FURN: EVAP COOLERS: TYPE OF USE: COM UNIT HEATERS: VENT FANS: OCCUPANCY GRP: B VENTS W/O APPL: VENT SYSTEMS: STORIES: 1 BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: DOMES. INCIN: LPG 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: REPAIR UNITS: FIRE DAMPERS ?: 30 - 50 HP: WOODSTOVES: GAS PRESSURE: 50 + HP: CLO DRYERS: FURN < 100K BTU: 1 AIR HANDLING UNITS FURN > =100K BTU: <= 10000 cfm: OTHER UNITS: > 10000 cfm: GAS OUTLETS: Remarks: Installation (1) 4 -ton gas pak w /duct & gas piping. Relocate existing distribution ducts for new floor plan. Project value: $5,000 Owner: FEES PACIFIC REALTY ASSOCIATES Description Date Amount 15350 SW SEQUOIA PKWY #300 -WMI [MECH] Permit Fee 8/28/03 $72.50 PORTLAND, OR 97224 [MECPLN] Plan Rev 8/28/03 $18.13 [TAX] 8% StateTax 8/28/03 $5.80 Phone: Total $96.43 Contractor: PROTEMP ASSOCIATES INC 9788 SE 17TH AVE PORTLAND, OR 97222 REQUIRED INSPECTIONS Phone: 233 - 6911 Gas Line Insp Duct Inspection Reg #: LIC 38868 Final Inspection This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 -001 -00 Issued By: LiA441 / • Permittee Signature: `' l` Call (503)639 -4175 by 7:00 P.M. for inspections neede he ne business day Mechmical Permit Application FOR OFFICE USE ONLY p� R eceived C/ Mechanical M�e�o..c�.∎��' Date/By: a (943 S D -' Permit No.: City of Tigard Planning Approval Date/By: Building 4 Permit No.: f 2 D0 g 94 13125 SW Hall Blvd. Plan Revie Other Tigard, Oregon 97223 Date/By: tr � 1. Permit No.: Phone: 503- 639 -4171 Fax: 503 -598 -1960 Post - Review Land Use Ua .di iV; `� Date/By: Case No.: Internet: www.ci.tigard.or.us -. N Contact Ju ® See Page 2 for 24 -hour Inspection Request: 503- 639 -4175 -' -' Name/Method: • Supplemental Information. TYPE OF WORK COMMERCIAL FEE* SCHEDULE - USE CHECKLIST . ❑ New construction ❑ Demolition Mechanical permit fees* are based on the total value of the work , ddition/alteration/replacement ❑ Other: performed. Indicate the value (rounded to the nearest dollar) of all CATEGORY OF CONS UCTION mechanical materials, equipment, labor, overhead and profit. ❑ 1 & 2- Family dwelling Commercial/Industrial Value: $ 7 000 See Page 2 for Fee Schedule ❑ Accessory Building ❑ Multi- Family RESIDENTIAL EQUIPMENT /SYSTEMS FEE* SCHEDULE Description I Qty I Fee(ea.) I Total ❑ Master Builder ❑ Other: Heating/Cooling _ JOB SITE INFORMATION and LOCATION Furnace - add -on air conditioning ** 14.00 Job site address: / s// j- s „, •g,./o/ 4 / may Gas heat pump 14.00 Suite #: /Se I Bldg. /Apt. #: Duct work 14.00 Project Name: Ge"STG AKc= eayse.zrAvr -S Hydronic hot water system 14.00 Residential boiler Cross street/Directions to job site: (for radiator or hydronic sy §tem) 14.00 Unit heaters (fuel, not electric) (in wall, in -duct, suspended, etc.) 14.00 Flue /vent (for any of above) 10.00 Subdivision: I Lot #: Repair units 12.15 Other Fuel Appliances Tax map /parcel #: Water heater 10.00 DESCRIPTION OF WORK Gas fireplace 10.00 If — Vii' Tt l�5 PA /G 6t/ /2x, fr.# / AZ p pl /Vc. Flue vent (water heater /gas fireplace) 10.00 �;Lc-A7Z� i57? IJC, Di /- 401463 Fryt_ Log lighter (gas) 10.00 Wood/Pellet stove 10.00 iVCG✓ r'LODIe. PG6ti Wood fireplace/insert 10.00 Chimney/liner /flue/vent 10.00 ) ROPERTY OWNER I ❑ TENANT Other: 10.00 Name: /' iQG T,Z c'5 / Environmental Exhaust & Ventilation Range hood/other kitchen equipment 10.00 Address: Clothes dryer exhaust 10.00 City /State /Zip: Single duct exhaust Phone:/ • c,3O0 Fax: (bathrooms, toilet compartments, ❑ APPLICANT ❑ CONTACT PERSON utility rooms) 6.80 Name: Attic/crawl space fans 10.00 Other: 10.00 Address: Fuel Piping City /State /Zip: * *($5.40 for first 4, $1.00 each additional) F etc. ** Phone: Fax: Gas heat pump .. E -mail: Wall/suspended/unit heater ** CONTRACTOR Water heater ** Business Name: RE 0 rexoP Fireplace ** Address: cr 7$g /7'" ' Range ** City /State /Zip: j-�CTL•N 0 eye q72zEz Clothes dryer (gas) ** Phone: .23s-<=1/1 I Faxa3 $- 976'7 Other: ** CCB Lic. #: 3 gg.c g Total: Mechanical Permit Fees* Authorized Subtotal: $ Signature: Date: $ /43 Minimum Permit Fee $72.50 $ '29. CO e5isl y %,..7 Plan Review Fee (25% of Permit Fee) $ /4. , / 4 7 (Please print name) State Surcharge (8% of Permit Fee) $ C, Ao TOTAL PERMIT FEE $ 9 (/ , y3 Notice: This permit application expires if a permit is not obtained within *Fee methodology set by Tri -County Building Industry Service Board. 180 days after it has been accepted as complete. * *Site plan required for exterior A/C units. i:\Dsts\Permit Forms\MecPermitApp.doc 01/03 Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial Fee Schedule: Total Valuation: Permit Fee: $1.00 to $5,000.00 Minimum fee $72.50 $5,001.00 to $10,000.00 $72.50 for the first $5,000.00 and $1.52 for each additional $100.00 or fraction thereof, to and including $10,000.00. $10,001.00 to $25,000.00 $148.50 for the first $10,000.00 and $1.54 for each additional $100.00 or fraction thereof, to and including $25,000.00. $25,001.00 to $50,000.00 $379.50 for the first $25,000.00 and $1.45 for each additional $100.00 or fraction thereof, to and including $50,000.00. $50,001.00 and up $742.00 for the first $50,000.00 and $1.20 for each additional $100.00 or • fraction thereof. Assumed Valuations Per Appliance: • Value Total Description: Qty (Ea) Amount Furnace to 100,000 BTU, including / 955 ducts & vents Furnace> 100,000 BTU including ducts 1,170 & vents Floor furnace including vent 955 Suspended heater, wall heater or floor 955 mounted heater Vent not included in appliance permit 445 Repair units 805 < 3 hp; absorb. unit, 955 to 100k BTU ' • ; • 3 -15 hp; absorb. unit, 1,700 • ' 1Olk to 500k BTU - 15 -30 hp; absorb. unit, 501k to 1 mil. 2,310 BTU 30 -50 hp; absorb. unit, 3,400 1 -1.75 mil. BTU >50 hp; absorb. unit, 5,725 >1.75 mil. BTU Air handling unit to 10,000 cfm 656 Air handling unit >10,000 cfm 1,170 Non - portable evaporate cooler 656 Vent fan connected to a single duct 446 • Vent system not included in appliance 656 permit Hood served by mechanical exhaust 656 Domestic incinerator 1,170 Commercial or industrial incinerator 4,590 Other unit, including wood stoves, 656 inserts, etc. Gas piping 1-4 outlets 360 Each additional outlet 63 • TOTAL COMMERCIAL $ VALUATION: i:\Dsts\Permit Forms\MecPermitAppPg2.doc 01/03 CITY OF TIGARD 24 -Hour BUILDING Inspection Line: (503) 639 -4175 MST INSPECTION Business Line: (503) 639 - 41!4`7 3 _ 0 0 y5 l Received Date Requested —Q / AM PM BUP Location / S/ / S Sk (v/ � / / Suite isc ,ria 3- Gia5 Contact Person Ph ( ) PLM Contractor Ph ( ) SWR C ° UILDI Tenant/Owner ELC Foundation Access: ELC Ftg Drain ELR Crawl Drain Slab Inspection Notes: SIT Post & Beam Shear Anchors Ext Sheath/Shear Int Sheath/Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof • , c1 - PART FAIL PLUMBING Post & Beam Under Slab Water he Water Service Sanitary Sewer Rain Drains Catch Basin / Manhole Storm Drain Shower Pan Other: Final T FAIL CHANIC Pos m Rough -In Gas Line Smoke Dampers r1• ?1_� PART FAIL ELECTRICAL Service Rough -In UG /Slab Low Voltage Fire Alarm Final Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE Please call for reinspection RE: ❑ Unable to inspect — no access Fire Supply Line ADA Approach/Sidewalk Date 3 Y Inspector Ext Other: Final DO NOT REMOVE this Inspection record from the job site. PASS PART FAIL