Specifications
• C_/ 7 - 01)6.3 2 Prepared by Robert 12/2/2007 fp a ,vP age 1 Steelhead Tech, Inc. • CONTRACTORS LICENSE #168965 11600- SE- Hathorne St Portland, Oregon 97216 (503)910 -9440 • FROM: Steelhead Tech, Inc. FOR: The Management Group, PacTrust Bldg #pcc241 11600 -SE Hathorne St- - 15350 SW Sequoia Ctr #200 Portland, Oregon 97216 Portland, Or 97224 (503)910 -9440 FIRE ALARM SUBMITTAL:, Tena it Improvements COVER PAGE EQUIPMENT SPECIFICATIONS and LISTINGS 1 . BLUE PRINTS WIRING DIAGRAM RISER LINE DRAWING-(FACP,KEYPAD,DEVICE) BATTERY .STANDBY CALCULATION • A) SYSTEM STANDBY TOTALS B) NOTIFICATION CIRCUIT(S) SCOPE OF WORK Addition /reinstallatiowta an existingwaterflow - detectionand - notification - system Initiation syste9 consists of monitored PIV tamper switch(s), water flow switch(s) mounted on the water main riser, combination Smoke/heat detector(s), HVAC DuctSmoke Deeector(s) and guilstation(s) as - noted. Eachrinitiation is tied into a .(alarm zone) of similar type devices. On site notification is accomplished with exterior 24VDC Horn/Strobe and interior notification devices as noted No can vice re be bc d/teplacedduetoienent TI, quantities and"device cations are denoted on accompanying pages. -- FACP - and sy_stemineet alt UFC - STD . 14 4, NFPA 72; CSFM, FCC; and UL - requirements - for commercial fire protection, to include dual phone line monitoring, line seizure, supervised trouble and fire notification (both on site and remotely monitored) of all initiation circuits back uppawer and `annunciation circuit supervision: ALL initiating -and notification circuits have an end of line resistor for circuit supervision. The FACP provides an unsupervised dry relay contact for elevator recall- use - or si filar use: = All wiringis to limitedfireprotective signaling circuit cable (FPL 16 -4) -4 conductor number 16 gage unless otherwise noted. All vertical wiring runs between floors, as applicable, are in conduit as per submitted plans. All - wires will in be in "trunks ". • Wires will run along walls; not across rooms. Horizontal - and vertical wire runs on one floor (level) will be above ceiling tiles, where applicable, or with-in wallsior crawl spaces. Any exposed wires; will feet orthose under seven will - be - in - AHJapproved mold-or conduit, as per NEC 760- 28(b)(1). Holes through firerated walls for wires will have conduit installed and will be tight having no annular space, • or alternatelywilr be fire° caulking - as per UBC'4304 exception (e) When wewi l provide a "FIRE ALARM INSIDE" sign, a FACP key to be incorporated with in a "KNOX BOX" and a sign displaying detailed inctions regarding "AL-ARM RESET" and SILENCE'procedures.: - . lam' ALARM CIRCUIT Control NAC #1 The Management Group, PacTrust Bldg #pcc24 Voltage 24 15350 SW Sequoia Ctr #200 ALARM SC Portland, Or 97224 DISTANCE TTL WIRE WIRE VOLTAGE DEVICE From Last WIRE # of RESISTANCE TOTAL LOSS DEVICE TYPE Candella IN AMPS DEVICE GAGE Wires IN OHMS IN AMPS IN my CONTROL NAC #1 DEVICE Ceiling Strobe' ' SCW ' 15 0.066 27 16 2 0.22 0.689 0.15 DEVICE Ceiling Horn/Strobe P(2W 15/75 0.08 13 16 2 • 0.11 0.623 0.07 DEVICE Ceiling Strobe SCW. 30 0.094 17 16 2 0.14 0.543 0.08 - DEVICE Ceiling Horn/Strobe PC2W 3 0.08 20 1 2 0.16 6.449 0.07 DEVICE Ceiling Strobe • SCW 15 0.066 13 16 2 0.11 0.369 0.04 DEVICE Ceiling Horn/Strobe PC2W 15/75 0.08 30 16 2 0.25 0.303 0.07 DEVICE CeilingHorn/Strobe PC2W 75 0.157 35 16 2 0.29 0.223 0.06 DEVICE Ceiling Strobe SCW 15 0.066 20 16 2 0.16 0.066 0.01 0 0 18 16 2 0.15 0 0.00 0 0 0 16 2 0.00 0 0.00 0 • 0 0 16 2 0.00 0 0.00 0 0 0 16 2 0.00 0 0.00 0 0 0 16 2 0.00 0 0.00 0 0 0 16 2 0.00 0 0.00 0 0 16 2 0.00 b 0.00 0 0 16 2 0.00 0 0.00 0 0 16 2 0.00 0 0.00 Control 0 16 2 0.00 0 0.00 193 FEET OF WIRE 0.56 my line loss # 18 WIRE = 6.51 OHMS /1000 FOOT 0.01302 24 vdc power # 16 WIRE = 4.09 OHMS /1000 FOOT 0.00818 # 14 WIRE = 2.58 OHMS /1000 FOOT 0.00516 2.32% # 12 WIRE = 1.62 OHMS /1000 FOOT 0.00324 KEEP UNDER 10% • COOPER Wheelock a 010 ��a° (932- Series HS Horn and Horn Strobe Appliances • 1R IF SERIES HS4 SERIES HS Description Features The Series HS4 Horn Strobe and HS Horn Appliances • Approvals include: UL Standard 1971, UL Standard 464, New are an ideal choice for retrofit applications as well as new York City (MI=A), California State Fire Marshal (CSFM) and installations. They satisfy virtually all requirements for Factory Mutual (FM) and Chicago (BFP) See approvals by indoor, wall and ceiling mount applications. model in Specifications and Ordering Information The Series HS Horn and the horn portion of the Series • ADA/NFPA/UFC /ANSI compliant HS4 include a selectable continuous horn tone or • Complies with OSHA 29, Part 1910.165 temporal pattern (Code 3) with three selectable dBA settings for each tone. • Field Selectable Candela Settings: Wall Mount 15/30/75/110cd or 135/185cd (Multi - Candela models) or 1575cd (single candela Strobe options include 1575cd or the Wheelock patented model) and Ceiling Mount 15/30/75/95cd or 115/177cd MCW Multi - Candela strobe with field selectable candela settings of 15/30/75/110cd or 135/185cd for wall mount • Selectable Continuous Horn or Temporal (Code 3) and 15/30/75/95cd or 115/177cd for ceiling mount. • 3 Selectable dBA settings of 90/95/99 dBA in both tones The Series HS4 horn and strobe inputs are electrically • 4-Wire Horn Strobe Appliance allows for separate operation of isolated to allow for independent operation of the strobe the horn and strobe circuits circuit and the horn circuit. The horn and strobe may also 24 VDC models with 16 to 33 VDC UL "Regulated Voltage" • be wired in parallel to operate on a single circuit. using filtered DC or unfiltered VRMS input voltage These versatile Horn and Horn Strobe Appliances Wall mount flush to standard 4 -inch square or • may be synchronized using Wheelock SM, DSM Sync double -gang boxes or surface mount to 10B backbox Modules or the PS- 24 -8MC Power Supplies with Wheelock patented Sync Protocol. • Synchronize with Wheelock Sync Modules or Power Supplies All models are designed for maximum performance, with built -in sync protocol reliability and cost - effectiveness while meeting or • Fast installation with IN /OUT screw terminals using #12 to #18 exceeding the latest requirements of NFPA 72/ANSI AWG wires 117.1/UFC and UL Standards 1971 and 464 as well as meeting ADA requirements concerning photosensitive epilepsy. • MEA l' I APPROVED S5391 151 -92 -E 7125-0785:161 4I . NOTE: All 'CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR ' OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU ANDIOR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their °Regulated Voltage Range °. Note that NFPA -72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • . All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 93% (t 2 %). . • Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the • terminology "Listed Voltage Range ". . ' Table 1: Ratings Per UL Standard 1971 ! ' Input Regulated . 1 Model Strobe Number Voltage Voltage Range Candela (CD) VDC VDC /FWR - HS4 - 24MCW 24 16.0 - 33.0 15/30/75/110 • 1 HS4- 241575W 24 16.0 - 33.0 _ 15 (75 on Axis) FHS4- 24MCWH 24 16.0 - 33.0 135/185 HS -24 • 24 16.0 - 33.0 - 1 HS4 -24MCC 24 16.0 -33.0 15/30/75/95 1 j HS4 - 24MCCH 24 16.0 -33.0 115/177 • Table 2: dBA Ratings for Horn . Reverberant dBA Anechoic dBA I I Audible Current I @ 10ft per UL 464 10 ft - -- - - - — — ' Description j Volume @ HS /HS4 HS and HS4 . 24VDC 24VDC i Series ! I 'j - - -- - - 1 High , 91 99 ; High (99) dBA Med (95) dBA , Low (90) dBA Continuous Med . 95 Horn ! L 24 vdc L _ 0.098 L 0.052 0.024 Low 83 90 UL max* 1 0.110 1 0.068 1 0.027 High 87 . 99 . Code 3 Med i 84 95 . Horn i ! Low 79 _._ -. Table 3: Average RMS Strobe Current' • 1 -- - - -- - - -- - -, Ceiling Mount L. Wall Mount -- - 24MCC ! 24MCCH 1 HS4- 241575W HS4 -24MCW HS4- 24MCWH 15cd 30cd 1 75cd i 95cd 1115cd 177cd ! 1575cd 15cd ; 30cd ! 75cd i 110cd 1135cd � 185cd 0.065 0.105 0.189 � 0.249 0.300 1 0.420 , -0.090 0.060 1 0.092 0.165 � 0.220 j 0.300 0.420 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16 -33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. . • Wiring Diagrams° HS4 or HS APPLIANCES SYNCHRONIZED WITH SM MODULE HS4 (4WIRE) APPLIANCE INDEPENDENT OPERATION OF AUDIBLE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILENCE SIGNAL AND STROBE FEATURE :;Z,=;"'" zPIM" • SM❑ Z ;',';∎ .n -"s+---'' — -1 - - -.- _U;':. .f4.Lr S:PI LI •.e7 1 N. ECL V :cnr i I 1 1-1 FD Ir TISTROBEPI I 1 �} V, Y I0 -05TROBF0 �' �! I StrDDeO ff r____ !!AG ' __1 I' +0 I A 1 Ci[cui I ;,1I ,�. S I T � y i C� I I � F:udib TC { ' i I+ ❑- • I i� EOLP I PD I ADdible0 �— _ A �� udlble:L NAM 11 PRECEDIHti= 1 r I . CI /C113.0 • �llho �--TI+ �j 2 F3 -7'1 -B =P I 4,KIA xUI PLY i� -- -- LCLPn PPeF • Horn and Strobe wired in parallel Horn and Strobe on separate circuits • HS4 AND HS APPLIANCES SYNCHRONIZED WITH DSM MODULE HS4 OR HS APPLIANCES SYNCHRONIZED WITH DSM MODULE DUAL CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE 2 CLASS "B" CIRCUITS FEATURE DSM DSM OsYNC . O/TYc a 0 1114c . 0 /TtIC - APPLIANCE IRON t6tLL r, + OUTt P� f OUTI /IODU /t NIYY/1 POND /t i / �ADDIBI[ 'I + > yTD NEXT APPLIANCE' :I.O.M. E I 1 - \ OREOLR + J� TO NEXT APPLIANCE' ♦vvLM/G!IlvvluYG[ ; ! PUTT - �OR EOLR R„ rII tlT •I RCUI I R UI / ARNIM Gu GY1T YtTtl YY t/ LIRGUR /] km Horn and Strobe wired in parallel Horn and Strobe on separate circuits APPLIANCE Note: HS4 or HS must be set on Code 3 horn tone to achieve synchronized temporal (Code 3) tone. Refer to installation instruction. Specifications and Ordering Information 1 i 1 Agency Approvals Model Number Order Strobe Non- Sync w/ SM, DSM I 24 I 2 I 4 1 Mounting • Code 1 Candela Sync or PS- 24-8MC I VDC I WIRE j WIRE' Options"' UL ; MEA CSFM FM BFP HS4 -24MCW FR I 3150 15/30/75/110 X X X � X I X i D,E,F,L,M,O,P,R X i X X X ' HS4-24MCW-FW 3151 15130/75/110 X X X I X I X D,E,F,L,M,O,P,R X X X X * 15 (75 on HS4- 241575W -FR 3176 • Axis) X X X 1 X X D,E,F,L,M,O,P,R X X X X • • HS4- 121575W -FR 3177 15 (75 on X X I X X I X D,E,F,L,M,O,P,R I X I X X X * Axis) i I • HS4- 24MCH -FR 3132 135/185 X X X I X 1 W X I D,E,F,L,M,O,P,R X X X ' • HS4- 24MCWH -RN 3148. 135/185 X X I X X I X D,E,F,L,M,O,P,R X X • X • * I HS -24-R 3152 -- X X X i X D,E,F,L,M,O,P,R I X X X X ' HS -24 -W 1 3153 - X X ! X 1 X —� j D,E,F,L,M,O,P,R X X X X HS4 - 24MCC -FR" 1 6264 - X X X X X D,E,F,L,M,O,P,R X X X X ' HS4 - 24MCC -FW • 6250 I - X X X 1 X I X D,E,F,L,M,O,P,R X X X X ' HS4- 24MCCH -FR•' 6228 - X X X' X i X D,E,F,L,M,O,P,R ! X X X X * HS4- 24MCCH -RN" 6225 1 - X X , X I X I X D,E,F,L,M,O,P,R I X I X X X • ' *PENDING " BUILD TO ORDER • Models are available in either Red or White. Call Customer Service for Order Code & Delivery. "Refer to Data Sheet S7000 for Mounting Options. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Architects and Engineers Specifications The audible /visual notification appliance shall be Wheelock Series HS4 Horn Strobe and HS Horn Appliances or approved equals. The Series HS4 and HS appliance shall meet ad be listed for UL Standard 1971 (Emergency Devices for the Hearing - Impaired for Indoor Fire Protection Service) and Standard 464 (Fire Protective Signaling). The horn strobe shall be listed for indoor use and shall meet the requirement of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP). The HS Horn and the audible portion of the HS4 appliance shall have a minimum of three (3) field selectable setting for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall ,incorporate a Xenon flashtube enclosed in a rugged Lexan ® lens. The Series HS4 shall be of low current design. Where wall mount, Multi - Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for: 15/30/75/110cd or 135/185cd. The selector switch for selecting the candela setting shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required. Where ceiling mount, multi- ' candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL standard 1971 for 15/30175/95cd or 115/177cd. When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock PS- 24-8MC Power Supplies with built -in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the . sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobes shall revert to a non - synchronized flash - rate. All notification appliances shall be backward compatible. • • • COOPER Wheelock NEM 273 Branchport Avenue • Member • Long Branch, NJ 07740 Phone: (800) 631 -2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732) 222 -2588 3 YEAR WARRANTY www.cooperwheelock.com Made•in USA S2400 HS 07/07 *Th, SYSTEM SENSOR° Selectable Output ' Horns, Strobes, and , r Horn /Strobes SpectrAlert' Advance selectable - output horns, strobes, and horn /strobes are rich with features guaranteed to p�� cut installation times and maximize profits. SPECTR lent A a V A N C E The SpectrAlert Advance series of notification appliances is Features designed to simplify installations, with features such as plug in • Electrically compatible with existing SpectrAlert products designs, instant feedback messages to ensure correct installation of • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 individual devices, and 11 field - selectable candela settings for wall candela and ceiling strobes and horn /strobes. • Plug -in design When installing Advance products, first attach a universal mounting • Field selectable candela settings on wall and ceiling units: 15, 15/75, plate to a four -inch square, four -inch octagon or double -gang '30, 75, 95, 110, 115, 135, 150, 177, 185 junction box. The two -wire mounting plate attaches to a single -gang Same mounting plate for wall- and ceiling -mount units junction box. • Shorting spring on mounting plate for continuity check before Next, connect the notification appliance circuit wiring to the SEMS installation terminals on the mounting plate. •Tamper resistant construction • Outdoor wall and ceiling products rated from -40 °F to 151°F Finally, attach the horn, strobe or horn /strobe to the mounting plate • Design allows minimal intrusion into the back box by inserting the product's tabs in the mounting plate's grooves. The • Horn rated at 88+ dbA at 16 volts device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place • Rotary switch for horn tone and three volume selections with a catch until it is secured with a captured mounting screw. • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements The SpectrAlert Advance series includes outdoor notification • Outdoor products rainproof per UL 50 (NEMA 3R) appliances. Outdoor strobes and horn /strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for • Compatible with MDL sync module wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Agency Listings SIGNALING ® E A 73.103 197 (outdoor Orobes) �rTV 7727 1553:186 (indoor sUObl's1 � ,r'� C Oj 7125 1653:1E9I /toolJ5oobe% • LISTED APPROVED approved ( 1 , Q > ._ 7136 16531991herns.ch I:r� „e„r rne l 54011 3023572 1:EA452-05 -E 55512 53593 • • • SpectrAlert Advance Specifications Architect /Engineer Specifications General SpectrAlert Advance horns, strobes and horNstrobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box or double -gang back box.Two-wire products shall also mount to a single -gang 2 x 4 x 1 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also. SpectrAlert Advance products, when used with the Sync- Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync - Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horr ✓strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95; 110,115,135,150, 177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Hom /Strobe Combination The horNstrobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit The products shall be listed for use with a System Sensor outdoor /weatherproof back box with half inch and three - fourths inch conduit entries. • Synchronization Module . The module shall be a System Sensor Sync - Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4" /16 x 4'vr6 x 2' /8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical /Electrical Specifications Standard Operating Temperature 32 °F to 120 °F (0°C to 49 °C) K Series Operating Temperature -40°F to 151°F ( -40°C to 66 °C) Humidity Range 10 to 93% non - condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61_ x 4.7 x 25 (142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61_ x 4.7 IN x 13 (142 mm L x 119mm W x 33 mm D) Wall -mount back box skirt dimensions (BBS -2, BBSW -2) 5.91_ x 5.0W x 2.2D (151 mm L x 128 mm W x 56 mrn D) Ceiling -mount back box skirt dimensions (BBSC -2, BBSCW -2) 7.1 "diameter x 225" high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA -WBB) 5.71 x 5.1'W x 2.0D (145 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA -WBBC) 7:1" diameter x 2.0" high (180 mm diameter x 51 mm hioh) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. • AOS-0395-003 • UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8-175 Volts 16-33 Volts 8-175 Vohs 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15' 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75' 142 148 77 81 Temporal Medium 44 49 58 69 30' NA NA 94 96 Temporal Low 38 44 44 48 75' NA NA 158 153 Non - temporal High 57 56 69 75 95" NA NA 181 176 Non - temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -wire Horn /Strobe, Standard Candela Range (15 -115 cd) 8-175 Volts 16-33 Vohs DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - temporal High 141 152 91 100 116 176 201 221 229 Non - temporal Medium 133 145 75 85 102 163 187 207 216 Non - temporal Low . 131 144 68 79 96 156 182 201 _ 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 • 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non - temporal High 142 161 103 112 126 181 203 221 229 Non - temporal Medium 134 155 85 95 110 166 189 208 216 Non - temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -wire Horn /Strobe, High Candela Range (135 -185 cd) 16-33 Vohs 16-33 Volts _ _ DC Input 135 150 177 185 FWR Input 135 150 _ 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - temporal High 255 270 303 309 Non - temporal High _233 248 275 _ 281 Non-temporal Medium 242 259 293 299 Non- temporal Medium 219 232 262 267 Non - temporal Low 238 254 291 295 Non - temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela Horn and Horn /Strobe Output (dBA) ratings must be reduced in accordance with this table. 24 Volt Nominal Strobe Output (cd) 8 -175 16-33 Switch Volts Volts Reverberant Anechoic Listed Candela I Candela rating at -40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 ; 1 Temporal High 78 78 84 84 88 88 99 98 - 15/75 j Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 I 3 Temporal Low 71 73 76 76 83 80 94 89 75 144 4 Non - temporal High 82 82 88 88 93 92 100 100 • 95 i 70 5 Non - temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non - temporal Low 75 75 81 81 88 84 96 92 115 115 7' Coded High 82 82 88 88 93 92 101 101 135 135 8' Coded Medium 78 78 85 85 90 90 97 98 _ 150 _ 150 9' Coded Low 75 75 81 81 88 85 96 92 • 177 177 'Settings 7, 8, and 9 are not available on 2 -wire horn/strobe. 185 l 185 .05.0795 -003 SpectrAlert Advance Dimensions — ___.___ . 4.7" 2.5 "—r 6.8" Dia. " iil 1 ..... .... i 1111 1* \ ,. 5.6 � I urn 4 . .. .........., , Wall -mount hom/strobes Ceding -mount hom/strobes frl 7.1" 7.1' 12.25 -1 2.0" Die. - 5.05 "� 1.-2.23=1 / —'� ` Dia. I / /� pI c 2 � I 00Q04 l ( / \ ( 5.98 a ( I. o ( o -. nigo ,/ 1D .T 4, ® l� o o a (-- O O n ___ _ = ® J O o o O r \�. . / r ``® \``` \ __ Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Wall Hom /Strobes Ceding Hom /Strobes (cont'd.) _ P2R "r 2 -wire Horn/Strobe, Standard cd°, Red PC2Wi 2 -wire Horn/Strobe, Standard cd, White P2RH" 2 -wire Horn/Strobe, High cd, Red PC2WH'' 2 -wire Horn/Strobe, High cd, White P2RK' 2 -wire Horn/Strobe, Standard cd, Red, Outdoor _ PC4R 4 -wire Horn/Strobe, Standard cd, Red P2RHK" 2 -wire Horn/Strobe, High cd, Red, Outdoor PC4RH 4 -wire Horn /Strobe, High cd, Red P2W 2 -wire Horn/Strobe, Standard cd, White PC4RK 4 -wire Horn/Strobe, Standard cd, Red, Outdoor P2WH' 2 -wire Horn/Strobe, High cd, White PC4RHK 4 -wire Horn/Strobe, High cd, Red, Outdoor P4R" 4 -wire Horn/Strobe, Standard cd, Red _ PC4W 4 -wire Horn/Strobe, Standard cd, White P4RH' _ 4 -wire Horn/Strobe, High cd, Red _ PC4WH 4 -wire Horn/Strobe, High cd, White P4RK 4 -wire Horn/Strobe, Standard cd, Red, Outdoor Ceiling Strobes P4RHK 4 -wire Horn/Strobe, High cd, Red, Outdoor SCR" Strobe, Standard cd, Red P4W" 4 -wire Horn/Strobe, Standard cd, White SCRH" Strobe, High cd, Red P4WH' 4 -wire Horn/Strobe, High cd, White _ SCRK Strobe, Standard cd, Red, Outdoor — Wall Strobes SCRHK Strobe, High cd, Red, Outdoor SR•T Strobe, Standard cd, Red SCWt Strobe, Standard cd, White SRH* Strobe, High cd, Red SCWH't Strobe, High cd, White SRK Strobe, Standard cd, Red, Outdoor Horns _ SRHK Strobe, High cd, Red, Outdoor HR Horn, Red SW Strobe, Standard cd, White HRK Horn, Red, Outdoor SWH' Strobe, High cd, White HW Horn, White Ceiling Hom/Strobes Accessories PC2R' 2 -wire Horn/Strobe, Standard cd, Red BBS-2 Back Box Skirt, Wall, Red PC2RH' 2-wire Horn/Strobe, High cd, Red BBSW -2 Back Box Skirt, Wall, White PC2RK 2-wire Horn/Strobe, Standard cd, Red, Outdoor BBSC -2 Back Box Skirt, Ceiling, Red PC2RHK 2 -wire Horn/Strobe, High cd, Red, Outdoor BBSCW -2 Back Box Skin, Ceiling, White • Notes: ' Add "-P° to model number for plain housing (no °FIRE° marking on cover), e.g.. P2R -P - 1 Add "-SP' to model number for "FUEGO on cover, e.g. P2R -SP # "Standard cd; refers to strobes that include 15, 1 S/75, 30, 75, 95,110, and 115 candela settings. °High cd: refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in "K' include a weatherproof back box. 6 ((- --1 �S cA cz006 system Sensor. Y SENSOR 3825 Ohio Avenue • St. Charles, IL h c>rua spro sogra:naurge N+rMM stcz.NSt s• stemsevdmm tar �` �\ ' Phone: 800-SENSOR2 • Fax: 630-377-6495 7-649 6495 c"'" pardon " °rn "' 0'°"''idin7i"ewev67 mdmsaata . RQ50391�00!•I'JOC•I166 SYSTEM • SENSOR° '�? u Selectable Output :F, of Horns, Strobes, and limo .11 s Horn /Strobes SpectrAlert Advance selectable- output horns, strobes, and horn /strobes are rich with features guaranteed to p cut installation times and maximize profits. SPECTIANert A ED V A IV C The SpectrAlert Advance series of notification appliances is Features designed to simplify installations, with features such as plug in • Electrically compatible with existing SpectrAlert products designs, instant feedback messages to ensure correct installation of • Automatic selection of 12- or 24 volt operation at 15 and 15/75 individual devices, and 11 field - selectable candela settings for wall candela and ceiling strobes and horn /strobes. • Plug -in design When installing Advance products, first attach a universal mounting • Field selectable candela settings on wall and ceiling units: 15, 15/75, plate to a four -inch square, four -inch octagon or double -gang 30, 75, 95,110, 115, 135, 150, 177, 185 junction box. The two -wire mounting plate attaches to a single -gang • Same mounting plate for wall- and ceiling -mount units junction box. • Shorting spring on mounting plate for continuity check before installation Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. • Tamper resistant construction • Outdoor wall and ceiling products rated from —40 °F to 151°F Finally, attach the horn, strobe or horn /strobe to the mounting plate • Design allows minimal intrusion into the back box by inserting the product's tabs in the mounting plate's grooves. The Horn rated at 88+ dbA at 16 volts device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place • Rotary switch for horn tone and three volume selections with a catch until it is secured with a captured mounting screw. • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements The SpectrAlert Advance series includes outdoor notification • Outdoor products rainproof per UL 50 (NEMA 3R) appliances. Outdoor strobes and horn /strobes (two wire and four • wire) are available for wall or ceiling. Outdoor horns are available for • Compatible with MDL sync module wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Agency Listings • SIGNALING — 7725 F A Y ;1254651186 (indoor slrol ,) IVIEA y1 730ir 16531971w1d°°r ;hr..ed C ri� 1 71251653'.1821hOm/5°°ues. approved � ' ♦♦ "im°'u' °n�.'. USTED APPROVED I 1 i13s 1653: 189(horn,.ch, , 54011 3023572 6@A452-05 -E 55512 53593 • SpectrAlert Advance Specifications Architect /Engineer Specifications o• General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box or double -gang back box.Two-wire products shall also mount to a single -gang 2 x 4 x 11/4-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn /strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95, 110, 115,135, 150,177, 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Hom /Strobe Combination The horn /strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor /weatherproof back box with half inch and three - fourths inch conduit entries. Synchronization Module • The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4"/16 x 4"/16x 21 -inch back box The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical /Electrical Specifications Standard Operating Temperature 32 °F to 120°F (0°C to 49°C) K Series Operating Temperature -40°F to 151°F (-40°C to 66 °C) Humidity Range 10 to 93% non - condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC /FWR or regulated 24DC/FWR' Operating Voltage Range 8 to 175 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8 "diameter x 2.5" high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61 x 4.7W x 2.50 (142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61 x 4.7W x 130 (142 mm L x 119 mm W x 33 mm D) Wall -mount back box skirt dimensions (BBS -2, BBSW -2) 5.91 x 5.0W x 2.2D (151 mm L x 128 mm W x 56 mm D) Ceiling -mount back box skirt dimensions (BBSC -2, BBSCW -2) 7.1 diameter x 2.25" high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA -WBB) 5.71 x 5.1W x 2.00 (145 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA-WBBC) 7.1 diameter x 2.0" high (180 mm diameter x 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time varying power source that is used on some power supply and panel outputs. 2. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05.03'9 .ox3 UL Current Draw Data . UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) • • 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15' 123 128 66 71 Temporal High 57 55 69 75 • Candela Range 15/75' 142 148 77 81 Temporal Medium 44 49 58 69 • 30' NA NA 94 96 Temporal Low 38 44 44 48 75` NA NA 158 153 Non- temporal High . 57 56 69 75 • • 95' NA NA 181 176 Non - temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 • High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -wire Horn /Strobe, Standard Candela Range (15 -115 cd) 8 -17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - temporal High 141 152 91 100 116 176 201 221 229 Non - temporal Medium 133 145 75 85 102 163 187 207 216 Non - temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non - temporal High 142 . 161 103 112 126 181 203 221 229 Non - temporal Medium 134 155 85 95 110 166 189 208 216 Non - temporal Low - 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -wire Horn /Strobe, High Candela Range (135 -185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 —_ Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 _ 303 309 Non - temporal High 233 248 275 281 Non - temporal Medium 242 259 293 299 Non - temporal Medium 219 232 262 267 Non- temporal Low 238 254 291 295 Non - temporal Low 214 229 • 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela Horn and Horn /Strobe Output (dBA) ratings must be reduced in accordance with this table. 24 Vok Nominal Strobe Output (cd) 8-175 16-33 Switch Volts Volts Reverberant Anechoic listed Candela i Candela rating at -40 °F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 I 1 Temporal High 78 78 84 84 88 88 99 98 • 15/75 ; Do not use below 32 °F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low. 71 73 76 76 83 80 94 89 75 1'1`1 4 Non - temporal High 82 82 88 88 93 92 100 100 - 95 I 70 _ 5 Non - temporal Medium 78 78 85 85 90 90 98 98 110 ' 110 6 Non - temporal Low 75 75 81 81 88 84 96 92 115 115 T Coded High 82 82 88 88 93 92 101 101 135 135 8' Coded Medium 78 78 85 85 90 90 97 98 150 1150 _ o Coded Low 75 75 81 81 88 85 96 92 177 177 'Settings 7, 8, and 9 are not available on 2 -wire horn /strobe. 185 185 A05 -0395 -003 • I • - SpectrAlert Advance Dimensions ' � 2.5 — X6.8" 1 •• Oi Dia. � iI / f f 1X11 , III `r► Wall -mount hom /strobes Ceiling -mount hom /strobes 2 .25" & 7.1" 7.1 -1 2.0" Dia. 5.05' 2.23- .—--D ia. c o 0 r 2.0" I , oo . oo , ® / / 5 .7" 5.98'' Alli • ' : � ° o ,I � ( / /� / J a �t l o•o d i 111■514 *,.\,,,,,\ Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn /Strobes Ceiling Hom /Strobes (cont'd.) P2R't 2 -wire Horn/Strobe, Standard cd Red PC2W ' 2 -wire Horn/Strobe, Standard cd, White P2RH' 2 -wire Horn/Strobe, High cd, Red PC2WH" 2 -wire Horn/Strobe, High cd, White P2RK' 2 -wire Horn/Strobe, Standard cd, Red, Outdoor PC4R 4 -wire Horn/Strobe, Standard cd, Red P2RHK` 2 -wire Horn/Strobe, High cd, Red, Outdoor PC4RH 4 -wire Horn/Strobe, High cd, Red___ _ P2W' 2-wire Horn/Strobe, Standard cd, White PC4RK 4 -wire Horn/Strobe, Standard cd, Red, Outdoor P2WH" 2 -wire Horn/Strobe, High cd, White PC4RHK 4 -wire Horn /Strobe, High cd, Red, Outdoor PC* HorNStrobe, Standard cd, Red PC4W 4 -wire Horn/Strobe, Standard cd, White P4RH` 4 -wire Horn/Strobe, High cd, Red PC4WH 4 -wire HorNStrobe, High cd, White P4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor Ceiling Strobes P4RHK 4 -wire Horn/Strobe, High cd, Red, Outdoor SCR" Strobe, Standard cd, Red P4W' 4 -wire Horn/Strobe, Standard cd, White SCRH' Strobe, High cd, Red P4WH' 4 -wire Horn/Strobe, High cd, White _ SCRK Strobe, Standard cd, Red, Outdoor Wall Strobes SCRHK Strobe, High cd, Red, Outdoor SR" Strobe, Standard cd, Red SCW*" Strobe, Standard cd, White SRH't Strobe, High cd, Red SCWH't Strobe, High cd, White_ _5RK Strobe, Standard cd, Red, Outdoor Horns SRHK Strobe, High cd, Red, Outdoor HR Horn, Red — SW' Standard cd, White HRK Horn, Red, Outdoor SWH" Strobe, High cd, White HW Horn, White Ceiling Hom/Strobes Accessories PC2R' 2 -wire Horn /Strobe, Standard cd, Red BBS -2 Back Box Skirt, Wall, Red PC2RH' 2 -wire Horn/Strobe, High cd, Red BBSW -2 Back Box Skirt, Wall, White___ PC2RK 2 -wire Horn/Strobe, Standard cd, Red, Outdoor BBSC -2 Back Box Skirt, Ceiling, Red - ------ - -- - -- ----------- ----- - - - - -- - -- -- - - - -- — -- - - - --- PC2RHK 2 -wire Horn/Strobe, High cd, Red, Outdoor BBSCW -2 Back Box Skirt, Ceiling, White Notes: ' Add " -P'to model number for plain housing (no "FIRE °marking on cover), e.g., P2R -P t Add' -SP'to model number for'FUEGO' marking on cover, e.g.. P2R -SP "Standard cd; refers to strobes that include 15, 15/75, 30, 75, 95,110, and 115 candela settings.'High cd °refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in"K'include a weatherproof back box. • *� SYSTEM CM. System s. �� SENSOR* 3825 Ohio Avenue • St. Charles, IL 60174 h scedficaw.msbm toown ,esmthout moos. Viz sstensseasacom4. Phone: 800- SENSOR2 • Fax: 630-377-6495 current vulva nt""„' °' 'miming the e"s"`"""m this data s�. a05 -0395-003. 1 • +1676 , MI ; e __ Y.y u 301-0" 30,_01 30'_0" , 1 -, . I I — ■I —I ( - NE 1° OFFICE OFFICE. OFFICE OFFICE 12071 12O8l 12111 12121 OFFICE 12061 /// . 1 __ I ,_1.1 (--ji CIRC. 12051 15175cd I - -tom WORK J L OPEN OFFICE OFFICE li 'C. 12091 r , 12101 12131 - 204 Cc FER. NCE - � L 1 ©� _ _ erl MAIL J 30Cd 1 II 15cc ° 20 . • ___ 1 I ________ _ ____________ ___±1 a ©1 CO 1 UP 30cd 12151 .. OPEN OFFICE r RECEPTIION @ ©II 12141 ON 1201 15cd I - - - - J - - -A 7_,/I - - - . , —C-� I - OFFICE - CI . C OFFICE I 1 EEO 1216 L _ 1 . r 7 - - 1 - 1 - 15cd D FILES _ - - II IT _ (¢ ©0 r 1 - 2281 OFFICE.- y B E'K 1 E 12191 229 L - OFFICE r l5/7 d 12201 J 60cd CIRC. ( � 51 0,0.4 1221 1 0 . c ,,.._. j OPEN OFFICE . 1 224 III OFFICE OFFICE 12231 1222 0 D _ D n O _ ►i_:: DPI 1 ,L OFFICE OFFICE OFFICE 1227 1226 12251 Oh 1 FIRE ALARM PLAN N CD SCALE 1/8" = 1' -0" THE MANAGEMENT GROUP . PACIFIC CORPORATE CENTER BUILDING #17 (PTR #241) SECOND FLOOR • . 15350 SW SEQUOIA PKWY #200 PORTLAND, OR 97224 12/14/07