Correspondence . . ,
,..•._ -
,.- , Structural: - Conce pts
,, • _ .
• DESIGN • ±CONSULTING : '. :ENGINEERING'... LLC
- October 23, 2003 r f
�
Mr. Tom Miller
Spacesaver Specialists, Inc.
9730 SW Herman Road '
Tualatin, OR 97062 -
Re: GeoEngineers Storage Racks
Seismic zone 3 shelving review
-
Dear Tom: .
:: , As requested, Structural Concepts LLC has analyzed the Lodi Metal Tech (LMT) storage racks to be placed
"' in the : office of GeoEngineers in the Pac Corp Center in Tigard, Oregon. We have reviewed the gravity and •
lateral capacity of the storage frames as per the requirements of the 1997 Uniform Building Code for
seismic zone 3. ,
,
•
1 ' . Our analysis was based on the criteria that the maximum load per shelf is 500 pounds. We have concluded
. . ''that the proposed shelving system is structurally adequate to meet the code requirements provided the
" . baseplates are anchored with (1)'/2 x 3' /z" embedment Hilti KB -II anchor. No special inspection is
required.
•
Please refer to the attached cut - sheets and calculations for design substantiation.' Note that this work was
` commissioned by Spacesaver Specialists, Inc.; for this
y p pec' specific file layout and location, and is not intended
to be used for any other purposes: Please call if you have any questions or comments.
Sincerely,: .
. '
'char. •deo, S.E.
' . Princip •
-4• J G r u 2
; '4
•
y � 13,370 6� . .
,. . r
t ,
1750 SW Skyline Blvd, Suite 223 • Portland, Oregon 97221.:,.
• • • 7 5031292.4540'4az:5031292.4104 •email structcon @mindspring.com_ ;'