Plans T '1 .
BUILDING LOCATION BUILDING INFORMATION f
O1 I ..
BUILDING OWNER: PACIFIC REALTY ASSOCIATES. L. P. r. F -• ''"�.``�:; , fir
mod 15350 S.W. SEQUOIA PKWY #300 / s. _?�
TO PORTLAND
AN PORTLAND, OR 97224 \.'..." L .L.;! ..
EXIT 0291 ( 503) 624 -6300 PHONE
( 503) 624 -7755 FAX PROJECT 00170
I R l ` 1 iia BLDG. #: PCC #14 (PTR #238) F"
_ . ;---11-111- �- C)
1 1 J � I \ SPR I NKLERED TO: ORDINARY HAZARD E
C ONSTRUC I TON: VN N
, .„.. . 1 1 1 1 = — ` -"`
g It a
1 1 1 1 `, f/ • - R G ��
TENANT I F d R
1, ` ` INFORMATION x '- a cA
s:' c� � � ."=-'' i �J ti� TENANT: SPEC SPACE �,
l
SEQUOIA PKWY \ O Q d _ _� o ��_ Ak O CCUPANCY : B O > r- (5 3
7 t.. _ 3 . liir I \ �� , Lt: x ° o z \ : / FLOOR AREA: 1 , 1 77 SF RENTABLE I~ 0 r. El A H J T1 1 , � �� x N G ` ' — [ Y o GENERAL NOTES z 61 MI
s tI J I — • ' 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE 0 N 0 0
ir WITH THE LATEST EDITION OF THE UNIFORM BUILDING CODE. ; -� r � AS AMENDED BY THE STATE OF OREGON AND ALL OTHER
p , \ � _, , ■ � i A . STATE OR LOCAL CODE REQUIREMENTS THAT APPLY.
sw 72ND AVENUE l
\ . . 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING
BUILDING AND NOTIFY ARCHITECT OF ANY DISCREPANCIES
PRIOR TO STARTING THE WORK. N
47t
3. CONTRACTOR SHALL KEEP THE AREA OF WORK FREE OF
GARBAGE AND DEBRIS ON A DAILY BASIS.
4. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8' THICK w
LOCATION MAP WITH TYPE 12 12" O.C. UNLESSSOTHERWISE W [�
NOT TO SCALE NOTED. U
p
/� I� Q 44 O00
" 5. IN FINISHED SPACES FURR OUT EXTERIOR WALLS WITH 5/8" as y 0
• GYPSUM BOARD OVER METAL STUDS W /R -13 FIBERGLASS c,/
CITY OF TIGARD INSULATION u 0 3 z
2 N
A . [it 6. INSTALL R -13 FS -25 INSULATION WITH STICK PINS TO w U w o
Conditionally Approved [ k CONC. WALLS ABOVE FURRING TO ROOF STRUCTURE d U N u
For only the wog( a described i ' 7. ACOUSTICAL CEILING SYSTEMS: h w ~ O a
PERMIT NO. jur MO -DDi SUSPENSION SYSTEM TO BE EXPOSED METAL T —BAR,
PREF I N I SHED WHITE, TO COMPLY WITH U. S. 0. STANDARDS. REVISIONS
See Letter to: Follow . [ r INSTALL LATERAL BRACING PER CODE.
Attach .[ r 8. H. V. A. C. TO BE A BALANCED, DESIGN —BUILD SYSTEM.
Job Address: l X2 1 e4 eA - ii fw
By: 2(7 Date: 4.X111 9. PROVIDE SPRINKLERS BELOW SUSPENDED CEILING PER CODE.
0 10. PROVIDE LABEL FOR EACH CIRCUIT AT PANEL FOR
I D E N T I F I C A I T O N PURPOSES. THERMOSTAT LOCATIONS TO BE DATE: 4/20/00
REVIEWED BY OWNER PRIOR TO INSTALLATION.
A-r 1
■'
4'
t
I O O
II . 90' - 0"
N H 4 5 ,. 0 . I 45._0.
b
a
%
•
ct
co
D
N
I ■IMI _ - _ N _ . _ _ _ _• _ _
g I I I o Q \J
0
1
•
0 I ; I
P ,C
0I
i ,
I
I
2, ./
.__ _. _. _ _ _. _. _ _ _ _ _ _ _ . _ _,0
L L •
U V
v > ,
d r SPACE FOR: JOHN H. ROMISH ARCHITECT ►ti , c
9 < 2216 S.E. 24TH AVE. O `. 7
to SPEC SPACE POR TLAND, OR 97214 M .
t z PACIFIC CORPORATE CENTER (503) 624 -6300 A 15230 S.W. SEQUOIA PKWY. #120 0 ,_,
N O PORTLAND, OR 97224 0 ..., : •
.. -
BUILDING #14 (VTR #238) V' .
0 0 ;
A P1e�duer pAOp�rY : _ ; . y
F� n 4 i
dr •
. 'S • i ,, . -
I I I .
I I ' '
I iuwuu....nuu1unu i I ,
b ! REFLECTED CEILING PLAN t
I 121 — — — a — I SCALE 1 /8" = 1' -O" O / /
HC RR , l!
I I
I - - - -
_ - - - - _ -- -. - _ -- I PROJECT 00170
I •� I F
OPEN SPACE , U
e i
I I I x N cA
0 It
L R
1 1
I ® I I V
. �� - I O a� T I
I I • A `° A
1.
I 1 I J I Z wz
XWP M a
0 6 0 o —,N
I 9 ' -9• I I
I I I
O
1+' 01 PARTITION AND POWER PLAN
tk
121
4(11 N
I I I SCALE 1 /8" = 1 -0"
1 121 HC RR F I I c
W
U
d N
I i 1 I I CONSTRUCTION LEGEND U ° ELECT. 120
-^� p Tom' GEAR OPEN SPACE ' Q 0 CC
I
EXISTING CONSTRUCTION 4 y 0
I PATCH AND REPAIR ALL EXISTING GYP. WALLS I I = = = = EXISTING TO BE REMOVED 0 CA 0 U " z
(OR GYP OVER) TO NEW CEILING ABOVE AND
PAINT. v)
I I I mm= NEW CONSTRUCTION U W O
INSTALL NEW GYP TO EXPOSED PLYWOOD AND P . p y U N 0
I OPEN STUD WALLS AS NEEDED AND PAINT.
vJ p. a
LEAVE PWMBING TRENCH OPEN FOR FUTURE
I ACCESS. I I REVISIONS
PATCH AND PAINT WOOD TRIM AT WINDOW SILLS
ADD PAINTED TRIM TO INSIDE OF DOOR 1 20
I I I
0 _ _ _ I 120 I I
I I I I T DATE: 4/20/00
I I I I I
I 1 I 1 I A-3
•
y Y
Y 5/e• PLYWOOD DECK FLOOR AND /OR ROOM STRUCTURE ' .
11 ri rr STABILIZER BAR BETWEEN '
LOCATE DIRECTLYSOVE MAINS AT PERIMETER
e/L,
G• F.G. INSULATION ADDITIONAL HANGERS AT ALL MAINS
- a444/„ . .. ,
.,--. n ' �.•-- +R.•: "R WITHIN 8° OF THE PERIMETER i
� 4 APPROVED VERTICAL STRUT AT 12' -O" O.C. EA. WAY
` r.G. INSULATION WITH 4 WAY LATERAL BRACING FROM THE MAIN
A A RUNNER TO THE STRUCTURE OVER BEGIN WITHIN 6' -0"
� • � 5/6* Gw ORD. STUDS 42 16. O G
6/6 GYP. BRD. —y— OF THE PERIMETER AND 2° FROM A CROSS MAMBER
•
kr. . ?
O CENTER UNE Or STUD I -
II _ 1F IFT.0 -- PROJECT 00170
iiiir , -"' [-I
U
s/D• TYPE WR. GYP. BRD. W
--48 CROSS MEMBERS BETWEEN CO
MAX MAIN RUNNERS U N
1111 li
AIN RUNNERS AT 4' -0" 0.C. It
Ot - P.O. INSULATION 6'-0" MAX
SUPPORT WITH #12 WIRE AT 4' -0' 0. Q g
0 BASE - Tt?.
Ot OR WITH #10 WIRE AT 5' - 0" O.C. [
roRP MATEWAL MULE \ ��• RUNNER CHANNEL - COUNTERSLOPE HANGERS IF MORE x I Q
= �� THAN 1:6 OUT OF PLUMB ATTACHED TO FLOOR 1- d • r-■ F
FINISHED rLOOR g SECURE ALL HANGERS TO BLDG. ,y '. .]_Y.�n1i
SEE rINISM SCMEDULE • 7 STRUCTURE OR A TRAPEZE FOR W N
roR MATERIAL . _ rINISM PLOOR-TOP OP SLAB DUCT AND /OR PIPE WORK 0 < z
NOTE: ALL CONNECTION DEVICES TO BE UBC 1'4
RESTROOM SIDE OFFICE SIDE O Q
APPROVED TYPE AND HAVE 100# CAPACITY • T 0 co
RESTROOM WALL DETAIL SUSPENDED CEILING BRACING z N A
0
z ► � r w w
SCALE I" = 1' -O" —�� NOT TO SCALE ►L+ t d; `4
maw' I, N 0 0
OGUNG DUALTUBC -
UGMT nxr. -
r o
0 Ina 'QUARC
rARA•QJDC
W
ro• N N
2'-O" - ra
1 r #
MIRROR n 13E SOFFIT uGr OAR
W�
u ■ W W d N 1.
F N
MIRROR -• U O d
3' 1'-0' 6• s' 9•- - a y 0
a, a cA 0 3 A
— I i 0 U y
w u
6 11
C �I 1 U W M
rwric LAM. ~ P d 0
PLASTIC LAM. I ' N
t I 9MeET VINYL cover, BABE I rum VINYL coves) er.s = REVISIONS
T -6• I V-6"
T-G" I -9•
DATE: 4/20/00
RESTROOM SOFFIT DETAIL RESTROOM ELEVATIONS A-4
0 SCA1.1: 1" = i' -O" SCALE I/4 =1-0"