Permit 1e ._ w CITY OF TIGARD ELECTRICAL PERMIT - RESTRICTED ENERGY �I� DEVELOPMENT SERVICES PERMIT #: ELR2004 -00188 13125 SW Hall Blvd.. Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 6/29/2004 SITE ADDRESS: 15055 SW SEQUOIA PKWY 100 PARCEL: 2S112DA -00800 SUBDIVISION: PACIFIC CORP. CENTER ZONING: I -P BLOCK: LOT: JURISDICTION: TIG Project Description: Limited energy for HVAC. A. RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: AUDIO & STEREO: INTERCOM & PAGING: BURGLAR ALARM: BOILER: LANDSCAPE /IRRIGAT: GARAGE OPENER: CLOCK: MEDICAL: HVAC: DATA/TELE COMM: NURSE CALLS: VACUUM SYSTEM: FIRE ALARM: OUTDOOR LANDSC LITE: OTHER: : HVAC: X PROTECTIVE SIGNAL: INSTRUMENTATION: OTHER: TOTAL # OF SYSTEMS: 1 Owner: Contractor: PACIFIC REALTY ASSOCIATES PROTEMP ASSOCIATES INC 15350 SW SEQUOIA PKWY #300 -WMI 807 NE COUCH PORTLAND, OR 97224 PORTLAND, OR 97232 Phone: Phone: 233 -6911 Reg #: ELE 26- 1063CRE LIC 38868 SUP 2613LEP FEES Required Inspections Description Date Amount Low Voltage Inspection [ELPRMT] ELR Permit 6/29/2004 $75.00 Elect'I Final [TAX] 8% State Surchar€ 6/29/2004 $6.00 Total $81.00 This Permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through • ° - • -:01-0 00. You may obtain copies of these rules or direct questions to OUNC at 503 246 -6699. Issue by . , 4 , Permittee Signature - OWNER INSTALLATION ONLY • The installation is being made on property I own which is not intended for sale, lease, or rent. OWNER'S SIGNATURE: DATE: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR. ELEC'N DATE: LICENSE NO: Call 639 -4175 by 7:00 P.M. for an inspection needed the next business day Electl, Permit Application FOR OFFICE USE ONLY City of Tigard Da : a9 Oil : `. • 13125 SW Hall Blvd., Tigard, OR 97223 Plan Review Phone: 503.639.4171 Fax: 503.598.1960 / /anvil* k I ei Date/B : Other Permit: Inspection Line: 503.639.4175 t1� 0 1 Date Ready/By: 7 See Page 2 for Internet: www.ci.tigard.or.us Notified/Method: Supplemental Information . TYPE OF WORK, • ..., - , , - , . : •_ t_ A RL N REVIEW ❑ New construction ❑ Addition/alteration/replacement Please check all that apply: ❑ Demolition ❑ Other: ['Service over 225 amps, comm'l ❑Hazardous location ['Service over 320 amps — rating ❑ Buildng over 10,000 sq. ft., CATEGORY OF CONSTRUCTION of 1- and 2- family dwellings 4 or more new residential ❑ 1- and 2- family dwelling ❑ Commercial/industrial ❑ Accessory building ['System over 600 volts nominal units in one structure El Multi - family ❑Master builder ❑ Other: ['Building over three stories ['Feeders, 400 amps or more ['Occupant load over 99 persons ['Manufactured structures or JOD SITE INFORMATION AND LOCATION ❑Egress/lighting plan RV park ❑Health -care facility ['Other: Job no.: Job site address: /O S S Sw SG tkjO/ a i ktA/ Submit 2 sets of plans with any of the above. City /State /ZIP: 7'Cp� The above are not applicable to temporary construction service. / ` � � , FEE* SCHEDULE . - . Suite/bldg. /apt.no.: ! O Project name: f Sl�cg- Description I Qty. I Fee. I Total I •• Cross street/directions to job site: New residential single -or multi - family dwelling unit. Includes attached garage. 1,000 sq. ft. or less 145.15 4 Subdivision: Lot no.: Ea. add'I 500 sq. ft. or portion 33.40 1 Tax map /parcel no.: • Limited energy, residential 75.00 2 Limited energy, non - residential 75.00 • 2 DESCRIPTION' OF WORK Each manufactured or modular Tr 57�T5 dwelling, service and /or feeder 90.90 2 Services or feeders installation, alteration, and/or relocation 200 amps or less 80.30 2 jan'ROPERTY OWNER I ❑TENANT: 201 amps to 400 amps 106.85 2 _ _ 401 amps to 600 amps 160.60 2 Name: 1 C / .— i 601 amps to 1,000 amps 240.60 2 Address: Over 1,000 amps or volts 454.65 2 Reconnect only 66.85 2 City /State /ZIP: Temporary services or feeders installation, alteration, and/or Phone: (s e, 3 Fax: ( ) relocation 00 ms �'� iv 0t 200 amps or less 66.85 1 Owner installation: This installation is being made on property that I own which is not 201 amps to 400 amps 100.30 2 intended for sale, lease, rent, or exchange, according to ORS 447, 449, 670, and 701. 401 amps to 600 amps 133.75 2 Owner signature: Date: Branch circuits — new, alteration, or extension, per panel • - ❑ APPLICANT ❑ CONTACT PERSON A. Fee for branch circuits with service or feeder fee, each 6.65 2 Business name: branch circuit B. Fee for branch circuits Contact name: without service or feeder fee, each branch circuit 46.85 2 Address: Each addi branch circuit 6.65 2 City /State/ZIP: Miscellaneous (service or feeder not Included) Pump or irrigation circle 53.40 2 Phone: ( ) Fax: : ( ) Sign or outline lighting 53.40 2 E -mail: Signal circuit(s) or limited- CONTRACTOR energy panel, alteration, or ]s • ^ 4 ' Business name: ^ _ extension. D sc �� / Page 2 ' ! 2 Each additional inspection over allowable in any of the above Address: .79 s e /7 -7-8, A Per inspection 62.50 City /State /ZIP: a n .410/ /v,_ cr7.222 Investigation per hour (l hr min) 62.50 Phone: (s-03) oZ �� ii Fax: b3) V, a , Industrial plant per hour 73.75 ELECTRICAL PERMIT FEES* CCB Lic.: 3 8e r Electrical Lic. ..z Suprv. Lic.: ,Xa/ 31,rP Subtotal 76 Suprv. Electrician signature, required: Plan review (25% of permit fee) ��� D State surcharge (8% of permit fee) 6 * Print name: 6.4:70 O' �ct144.•Epe'ie TOTAL PERMIT FEE $/ .c,C) Authorized signature: This permit application expires if a permit is not obtained within 180 J days after it has been accepted as complete Print name: ,..7'2"z c/"I� t' l Dated / /� • Fee methodology set by Tri- County Building Industry Service Board ` 66 •• Number of inspections per permit allowed. i:\ Building \Permits\ELC- PermitApp.doc 12/03 440. 4615x(10 /O2/COM/WEB Electrical Permit Application - City of Tigard - Irk Page 2 - Supplemental Information LIMITED ENERGY PERMIT FEES: ! RESIDENTIAL WORK ONLY: __ —._ -- Fee for all residential systems combined ... $75.00 Check Type of Work Involved: ❑ Audio and Stereo Systems* ❑ Burglar Alarm ❑ Garage Door Opener* ❑ Heating, Ventilation and Air Conditioning System* ❑ Vacuum Systems* ❑ Other: COMMERCIAL WORK ONLY: Fee for each commercial system $75.00 (SEE OAR 918 260 - 260) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations i:\ Building \Permits\ELC- PemotApp.doc 04/03 CITY OF TIGARD 24 -Hour BUILDING Inspection Line: (503) 639 -4175 INSPECTION DIVISION Business Line: (503) 639 -4171 MST BUP Received Date Requested $-� AM PM BUP Location 6 SS- Suite /00 MEC Contact Person 6/i-1� _ Ph ( ) 2 33 l/ PLM Contractor Ph ( ) SWR BUILDING Tenant/Owner ELC Footing Foundation ELC Ftg Drain Access: ELR .0? 2 ¥ - 06 / 8 S ) Crawl Drain Slab Inspection Notes: SIT Post & Beam Shear Anchors Ext Sheath/Shear Int Sheath/Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof • Other: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Rough -In Water Service Sanitary Sewer Rain Drains Catch Basin / Manhole Storm Drain Shower Pan Other: Final PASS PART FAIL MECHANICAL Post & Beam Rough -In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough -In UG/Slab Low Voltage Fire Alarm S PART FAIL El Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. S TE E Please call for reinspection RE: Unable to inspect — no access Fire Supply Line ADA Approach/Sidewalk Date gig/ Inspector L �' Ext Other: Final DO NOT REMOVE this Inspection record from the j site. PASS PART FAIL