Loading...
Correspondence City of Tigard, Oregon • 13125 SWHall Blvd. • Tigard, OR 97223 • July 19, 2007 ® . RE: MECHANICAL TI 4N t 'ro'' '+. Y L4 ¥E oTIRRD Project Information Building Permit•. MEC2007 -00435 Construction Type: IIIB Tenant Name: Pacstar Occupancy Type: B Address: 15055 SW Sequoia Occupant Load: 120 Area: NA. Stories: 1 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2007 edition; and the State of Oregon Fire Code (OFC) 2007 edition. The submitted plans are approved subject to the following GENERAL 1. Ductwork shall be supported in accordance with Sheet Metal & Air Conditioning Contractors National Association, Inc. (SMACNA) 2. Equipment and appliances regulated by this code requiring electrical connections shall have a positive means of disconnect in accordance with the Electrical Code. 301.7 OMSC 3. Appliances shall be accessible for inspection, service, repair or replacement without removal of permanent construction. 306.1 OMSC 4. Manufacturer's installation instructions shall be available on the jobsite at the time of inspection. 304.1 OMSC 5. Condensate from cooling coils or evaporators shall be collected and discharged to an approved plumbing fixture or disposal area. 307.1 OMSC 6. Smoke detectors shall be installed in return air systems with a design capacity greater than 2000 cfm. Upon activation, the smoke detector shall shut down the air distribution system. Smoke detectors shall be connected to a fire alarm system and shall activate an audible and visible alarm at a constantly attended location. 606.2, 606.4 & 606.4.1 OMSC 7. VAV boxes shall be supported by non - combustible elements that are designed and constructed to accommodate the weight and dynamic loads and shall be sway braced. 920.2 OMSC Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, -1 ' 0010 Dan Nelson, Senior Plans Examiner