Correspondence . Slow ":.kais
IN � razan & ASSOCIATES INC.
GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING & INSPECTION
February 24, 2003 ICA No. 086 -03001
Mr. Kirk Bezanson
1 I /
The Home Depot
370 Corporate Drive North A Q
Tukwila, WA 98188 f
RE: Construction • • '1! and Inspection
e Depo . !I Center • • : on
14800 SW Sequoia Parkway
tja.-{) -
Tigard, Oregon
Dear r. : : - -. - - •,
In accordance with your request and authorization, our firm performed construction testing and inspection for
the above - referenced project. The inspections were performed by our inspectors on the following dates:
• Structural Steel dated February 11, 2003 iV _ - . _ / /
• Structural Steel dated February 12, 2003 0 G>
If you have any questions or if we can be of further assistance, please do not hesitate to contact our office.
Respectfully submitted,
I. • • N & ASSOCIATES, INC.
cj'(/
Elizabeth Vaitautolu
Administrative Assistant
Vancouver Office
CC DAVID FAWLEY, OMICRON
CITY OF TIGARD BUILDING DEPARTMENT
4 r-_T
G"
" KraZan 86 ASSOCIATES,INC.
GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING & INSPECTION
DAILY FIELD REPORT
Date of Inspection: February 11, 2003 Report Number: 21103
Kirk Bezanson Project Number: 08603001
The Home Depot Project Name: Home Depot Tool Center Addition
370 Corporate Drive North Project Address: 14800 SW Sequoia Parkway
Tukwila, WA 98188 Tigard, WA
Project Number: 08603001
Type of Inspection Performed: Structural Steel — Field
Items Inspected: 3/8" Fillet welds at horizontal T.S. beam to T.S. column connection
Location: Line H, future doorway frame
Position Filler Metal Process Weld Type Weld Size Codes
Flat, Vertical, E71T -1 FCAW Fillet 3/8" AWS, UBC
Overhead
Discrepancies Listed Below : Yes I I No I X
NOTES:
Krazan was onsite as requested to perform continuous weld inspection of 3/8" fillet welds as required by AWS
D1.1 -02. Krazan was on standby for an hour and a half waiting for piece to arrive from fabricators. Piece erected
after arrival, T.S. 6 x 6 x 1/4 welded to T.S. 6 x 6 x 1/4 columns with 3/8" fillets, and to (3) through bolt anchored
12 x 12 1/2 plates with 3/8" flare bevel fillets per approved plans.
Note: Approved plans call for 3/8" fillets all around at horizontal T.S. to columns T.S. connection, but only 3
sides out of 4 possible for weld due to access. Engineer contracted and verbally accepted (3) welded sides,
paperwork will be faxed to Krazan. Work observed per plans and specifications.
To the best of my knowledge, the above was in accordance with the Uniform Building Code, approved plans and
specifications, and local regulatory requirements.
Inspector/Technician: Dave Selander Certification #: COP 769
If you have any questions regarding the information listed above, feel free to call us at (360) 254 -3200.
Sincer=
i
r" is Gessner .
Construction Services Manager
Southwest Washington & Oregon Division
Kr
azan
86 ASSOCIATES,INC.
GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING 8s INSPECTION
DAILY FIELD REPORT
Date of Inspection: February 12, 2003 Report Number: 21203
Kirk Bezanson Project Number: 08603001
The Home Depot Project Name: Home Depot Tool Center Addition
370 Corporate Drive North Project Address: 14800 SW Sequoia Parkway
Tukwila, WA 98188 Tigard, WA
Project Number: 08603001
• Type of Inspection Performed: Structural Steel — Field
Items Inspected: Beam clips, stub columns, 63 x 3 x 3/16 struts, A325 -N bolted connections,
braced frame
Welder qualification/certification FCAW
verified for:
Position Filler Metal Process Weld Type Weld Size Codes
N/A E71T -1 FCAW Fillet N/A AWS, UBC
•
Discrepancies Listed Below : I Yes I I No I X
NOTES:
Krazan was onsite as requested to perform high strength bolting and welding onsite. Area of inspection of new
tool center roof level, addition of new W14 x 22 beams, stub columns, struts, and welded beam clips. Also
verified welds at new T.S. braces. (1) Beam not yet installed, under existing W14, concrete column must be
removed prior to beam erection. Beam clip already installed and verified. All bolting of A325 -N complete, snug
tight requirement only. Work observed per approved plans and project specifications.
To the best of my knowledge, the above was in accordance with the Uniform Building Code, approved plans and
specifications, and local regulatory requirements.
Inspector/Technician: Dave Selander Certification #: COP 769
If you have any questions regarding the information listed above, feel free to call us at (360) 254 -3200.
Sincer
Eric Gessner
Construction Services Manager
Southwest Washington & Oregon Division
FROM : Krazan a n000c, FIIX MO. 360549400 Mar. 31 2003 09:49f1M P1
•
I(raZ & ASSOCIATES , INC.
GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING
•
CONSTRUCTION TESTING & TNSPT+',CTTON
November 18, 2002 KA No. 086 -03001
Permit No.: BUP- 2002 -00535
Mr. Kerry Swanson
The Ilome Depot
370 Corporate Drive North .
Tukwila, WA 98188
•
RP: Final Letter Regarding
Hume Depot Tuul Center Addition
14800 SW Sequoia Parkway
Tigard, OR
•
Dear Mr. Swanson:
This is to certify that, in accordance with Section 1701 of the State Building Code, we have
performed special inspections of the following items:
• Reinforced Concrete
• Structural Field Welding and Bolting •
• Epoxy Anchors
All inspections and tests were performed and reported in accordance .with the requirements of the
approved plans, specifications and the Uniform Building Code, and to the best of my knowledge,
the work was in conformance with the applicable workmanship provisions of the State Building
Code and Standards.
If you have any questions or if we can be of further assistance, please do not hcsitatc to contact
our office at (360) 254-3200.