Correspondence /'ao 97,3 Rick Bolen From: Rick Bolen Sent: Friday, March 28, 2008 7:26 AM To: Hap Watkins Cc: Maris Buxton Subject: RE: HMC Scoffins Move -in Hap, On my last inspection report I listed five (5) items, and they are as follows: 0 1 SDR20'. : %s04; PLM200 4 :1; PLM20070 0; MEC & ELC Permits req'd for the two (2) /C's installed. �� VvVVV .^ /C 6-A k4- - I'D Note: The SDR20�-90004 condition is the only remaining rT item. Both PLM's have been inaled. Still no permits '' I S i KAVJ "1/ for the A /C's. 2vv . L� /R / Q' A permanent 2 -way communication device needs to be installed. The temporary device ,Def7 ctually penetrated through the firewall with wiring - no go. ®. The emergency lighting needed to be moved to light the non -lite signage at the "Area of Rescue." 4 Repair rated wall- once item 2 above changed out. . Exterior stairs (front side) incompleted at time of inspection. The guard rail was too g o // o w and had to be corrected. Note: The exterior stairs was blocked off for the "Temp. C /O." Rick - - -- Original Message From: Hap Watkins Sent: Thursday, March 27, 2008 3:26 PM To: Rick Bolen Subject: FW: HMC Scoffins Move -in What is outstanding for McMonagle Office Building ? ? ?? Original Message From: Maris Buxton Sent: Thursday, March 27, 2008 2:17 PM To: 'Bill McMonagle'; jay @h - mc.com Cc: Hap Watkins Subject: RE: HMC Scoffins Move -in Bill, I am forwarding this to our Inspection Supervisor, Hap. He can tell you what you still need to correct. Thank you, Maris 1 Original Message From: Bill McMonagle [mailto:bill @h - mc.com] Sent: Thursday, March 27, 2008 2:14 PM To: Maris Buxton Subject: RE: HMC Scoffins Move -in WILL YOU PLEASE SEND ME A LIST OF THINGS TO BE DONE FOR THE FINAL BUILDING INSPECTION. I AM NOT AWARE OF WHAT MAY BE MISSING. THANKS, BILL MC Original Message From: Maris Buxton [mailto:maris@tigard - or.gov] Sent: Thursday, March 27, 2008 1:36 PM To: Bill McMonagle Subject: RE: HMC Scoffins Move -in Bill The plumbing final was on March 20th. .(The one on the 14th failed.) So once you get your final Building Inspection for BUP2006 -00493 you'll be all set! -Maris Original Message From: Bill McMonagle [mailto:bill @h - mc.com] Sent: Thursday, March 27, 2008 12:54 PM To: Maris Buxton Subject: RE: HMC Scoffins Move -in MARIS, I BELIEVE THAT ALL PLUMBING INSPECTIONS HAVE BEEN COMPLETED AND APPROVED AS OF 03 -14- 08 PER PLM 2007 - 00360, CODE 399 PLUMBING FINAL. PLEASE CONFIRM. BILL MC Original Message From: Maris Buxton [ mailto:maris@tigard- or.gov] Sent: Wednesday, March 12, 2008 8:12 AM To: Bill McMonagle Subject: RE: HMC Scoffins Move -in I am referring to the plumbing for the building. Your inspector is John Williams. 503 - 718 -2431. Hopefully your plumber has made any corrections called out at the last inspection. Thank you, Maris Original Message From: Bill McMonagle [mailto:bill @h - mc.com] Sent: Tuesday, March 11, 2008 9:23 PM To: Maris Buxton Subject: RE: HMC Scoffins Move -in 2 w . JAY MIKE WHITE INSPECTED THE OFFSITE SAN AND STORM PUBLIC AND PVT. I HAVE NOT HEARD FROM SCOTT HEWETT BUT HE KNEW THAT THE INSPECTION WAS A QUESTION THAT NEEDED TO BE ANSWERED I THINK HE DID BUT WITH WHO ?. SCOTT RETURNS THURSDAY Original Message From: "Maris Buxton" <maris@tigard- or.gov> To: "Emily Eng" <Emily@tigard- or.gov>; "'Jay Harris'" <jay @h- mc.com> Cc: "Bill McMonagle" <bill @h - mc.com>; "Hap Watkins" <HAP@tigard- or.gov> Sent: 3/11/08 3:45 PM Subject: RE: HMC Scoffins Move -in Jay, I also see that you failed your final plumbing inspection on 2- 28 -08. I would recommend you contact Hap Watkins and make sure you are going to be able to get all your finals soon. I know that Hap has communicated with Bill regarding this on 2- 11 -08. Thank you, Maris From: Emily Eng Sent: Tuesday, March 11, 2008 3:37 PM To: 'Jay Harris' Cc: Bill McMonagle; Maris Buxton Subject: RE: HMC Scoffins Move -in Jay, Before I can do a final walk- through, I need to receive the following items with a cover letter addressing each item: Condition 8 (Final Arborist Report) Condition 29 (Deed Restriction for Trees): Please submit a copy of the recorded deed restriction (with the County's stamp). Condition 30 (Solid Wood Fence for Screening Refuse Container): Please address the fact that you are putting up a cash assurance for the wood fence • in your cover letter. The cash assurance can be in the form of Cash or Check payable to City of Tigard for the value of the trash enclosure, to be refunded once it is installed. Condition 31 (Apply for a Sign Permit): Although you are not proposing to install a sign immediately, this condition was required because the SDR application indicated a sign would be in the public ROW. To ensure that a sign will not be in the public ROW, you need to submit an application for a sign permit prior to the final inspection. The sign permit allows you to construct the sign within 90 days of approval and can be extended for an additional 90 days if you can show intent to construct. If you are not sure of the exact design, you may submit a general design, showing the intended type of sign with the intended dimensions and in the intended location. It may also need a building permit, depending on the type and size. The sign permit is $40. Revised bike parking plan: Bill was supposed to submit a site plan to me with the new location of the bike rack, indicating a hard surface underneath (such as pavers) and a directional sign indicating the bike parking (since it is not visible from the building entry or right -of -way). This could technically be a Minor Mod application, but I did not require it. A revised plan for our files is sufficient. I cc'd Maris Buxton, who has recently communicated to Bill about remaining conditions. 3 Thanks, Emily Emily Eng Assistant Planner City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 P: (503) 718 -2712 F: (503) 718 -2748 www.tigard - or.gov From: Jay Harris [mailto:jay @h - mc.com] Sent: Tuesday, March 11, 2008 12:14 PM To: Emily Eng Cc: Bill McMonagle Subject: HMC Scoffins Move -in [ cid: image001.jpg @01C8838E.D0F39C40] Emily: The siteworks on our Scoffins building is near completion, . and we are hoping to move -in on Friday morning... The landscaping and bike rack should be done today /tomorrow. The exterior fencing is complete. (Condition #30). The trash enclosure will be installed Thursday (or I will deposit a check with you). Bill McMonagle e- mailed over the deed restriction for the trees (Condition #29) but it is not signed off in the computer. Condition #31, Apply for sign permit, is not being used at this time. We are waiting to lease the lower space before we get going on the sign. Can you meet onsite tomorrow for a walk thru? Thanks Jay Harris 4 , ,„Gu%°ac 7-0 6 - C 5` '7y4 -644/ ,S f ,'� s 5-I Rick Bolen From: Hap Watkins Sent: Thursday, March 13, 2008 8:55 AM To: 'jay @h- mc.com'; Maris Buxton Cc: Rick Bolen Subject: Cert of Occupancy I am concerned that there are so many permits outstanding. You indicated that you would like to move in and occupy on Friday the 14th, but no inspection requests were called today. I have asked Rick to contact you with issues that must be completed prior to occupancy, temporary or final, most important of which are the approvals of the engineering and planning departments. I will be in the field most of the day, so your best contact is Rick at his cell # 503 - 367 -7118. You can also call Maris at 718 -2453 as she has all the most current status reports for cert of occ or final inspections. CIO'y 4... ? 1 0-1 3 .4, s 1 Rick Bolen F7y0 From: Rick Bolen Sent: Tuesday, January 29, 2008 9:07 AM To: Brian Blalock Cc: Dan Nelson Subject: RE: McMonagle Building Brian, As far as I know, there has been no Stop Work Order placed at this site and the construction has not been held up for any reason. There was a miscommunication regarding the fire /smoke dampers, but this was resolved almost immediately. During the stages of construction, as noted within the file of the master permit, the process has been punctual and was without a hold -up on our part. The contractor at times, had work that was either not ready or requests incorrectly called in, but I handled these situations routinely and worked with them to get it back on schedule. Brian, the issue with the fire /smoke dampers was written on 12 -26 -07 by Dan on a scheduled "drywall" inspection card. I had been there earlier on 12 -24 -07 for the drywall inspection requested for the AM. This was primarily for the corridor and property line firewalls, but they were "not ready" upon arrival at 10:05 AM. Upon returning from vacation, I retrieved a 12 -26 -07 phone message at 08:40 AM from Lloyd (superintendent) regarding the drywall inspection done by Dan. I returned his phone call on 1 -2 -08 and explained that I would find out what happened and asked that he recall for the inspection on the IVR System. On 1 -4 -08 at 08:37 AM, I received another call from Lloyd via Debbie (Front Counter) at 09:04 AM requesting an AM to another drywall inspection. Upon arrival, again they were "not ready ", whereas I just cancelled the inspection and not subjecting them to a re- inspection fee. On 1 -8 -08 another drywall inspection was requested with a message for an AM. During my inspection, I identified the GA detailing from the plans and found that they had already covered the base layer without inspection. I went through the building viewing other areas and determined that if they used the spacing of fasteners on the firewall(s) as they had on others, that I could approve the base layer on the basis "by appearance." The second layer was ok, except for the interior side along the property line. I failed the inspection, because they had forgotten the basement side of the stairwell and I asked for a tighter pattern at the property line firewall. On 1 -9 -08 I returned to do another drywall requested inspection and approved it. Brian, I thought maybe you should know the history of this site due to the stirring of talk within the office about a possible $20,000 claim that we held them up aimed at the inspection done by Dan. As you can see, we did nothing of a sort. Rick Brian Blalock Sent: Monday, January 28, 2008 1:24 PM To: Hap Watkins; Rick Bolen; Walter Barnett; John Williams; Gary Noble; Dan Nelson Subject: FW: McMonagle Building Can anyone shed some light on this for me? • From: Tom Coffee Sent: Monday, January 28, 2008 12:42 PM To: Brian Blalock Subject: RE: McMonagle Building 1 All I have is that due the use of some type of non -code compliance material (that "should have been noted in the plan review "), the project was red tagged until a correction was made thereby (allegedly) costing the contractor(Marland) $20,000! From: Brian Blalock Sent: Monday, January 28, 2008 12:26 PM To: Tom Coffee Subject: McMonagle Building As far as any rated construction was concerned, the rated corridors and property line walls were indicated on the plans that we approved.? I need more information on the concern, if it's available. 2 xi Nicoll Engineering, Inc. PO Box 23784 Tigard, Oregon 97281 • Phone: • Fax: 03 g g e (503) 620 -2086 a (5 ) 684 -3636 March 13, 2008 NEI #: 07 -0111 City of Tigard RECEIVED ATTN: Hap Watkins MAR 1 4 2008 13125 SW Hall Blvd Tigard, OR 97223 CITY OF TIGARD BUILDING DIVISION Re: Substantial Completion of New Office for Harris - McMonagle Associates Project: Building Permit: 2006 -00491 3u iP2p66-aD Scoffins Property LLC McMonagle Office Building 8740 SW Scoffins Street Tigard, OR 97223 Dear Mr. Watkins: To the best of our knowledge the construction of the above noted project has been substantially completed per the permit documents prepared by our office. It should be realized that we were not retained or asked to perform onsite structural observations during the construction of this project. However, we did visit the site to resolve other minor issues. If you have any further questions regarding this matter, please do not hesitate to contact our office at your earliest convenience. Sincerely, E��p P RO,c - S�vINt - ' \ 1 • ,50 t f, / , , 4 7/. J t <*- 0 18, ,9 ��J 1 N.K v ,4 11 E.N. Ketchum, PE ENK:dhl X:12007U -070111 Scoffins Street LLC - Hams McMonagle New BuildinglLetters%Fina! Summary Letter 031308.doc Page 1 of 1 9025 SW Center Street Tigard, OR 97223 — www.nicoliengineering.com City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 II • • April 17, 2007 T I GARD RE: HARRIS - McMONAGLE OFFICE BUILDING Project Information Building Permit: BUP2006 -00493 Construction Type: VB Address: 8740 SW Scoffins St. Occupancy Type: B Area: 7500 sq. ft. Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; 2005 edition and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. FIRE LIFE AND SAFETY / GENERAL The main exterior door or doors are permitted to be equipped with key- operated locking devices from the egress side provided: 1. The locking device is readily distinguishable as locked, 2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background. (Sec. 1008.1.8.3) All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (Sec. 1008.1.8) Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. (Sec. 1011.1) Exit signs shall be illuminated at all times and shall be provided with a second source of power that will provide 1 1/2 hours of illumination in case of primary power loss. (Sec. 1006.3) FYI Additional exit signs may be required by the city field inspector to clearly indicate the path of egress. Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level anytime the building is occupied. The means of egress illumination shall be provided with a second source of power in case of primary power loss. (Sec. 1006.2) Live Loads Posted: The live loads for which each floor has been designed to exceed 50 psf shall be conspicuously posted by the owner in that part of each story in which they apply, using durable metal signs, and it shall be unlawful to remove or deface such notices. The occupant of the building shall be responsible for keeping the actual load below the allowable limits. (1603.3 OSSC) American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. (106.3.1 OSSC) Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy (109.1 OSSC) Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Respectfully, ( b l ir ' I ' , e•s lson S enior Plans Examiner • City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 April 17, 2007 TIGARD Bill McMonagle Scoffings Prop. LLC 12555 SW Hall Blvd. Tigard, Or. 97223 RE: ISSUANCE OF BUILDING PERMIT Project Information Project Name: Harris - McMoagle Construction Type: VN Building Permit: BUP2006 -00493 Occupancy Type: B Address: 8740 SW Scoffins Street Occupant Load: 46 Dear Nick, The Building Division has completed the review of the project listed above. The project has not been released by either the Planning Division or the Engineering Division at the time of this letter, so the Building Permit cannot be issued. If you have questions please contact Mans Buxton @ 503 - 718 - 2453. The date of this letter begins the 180 clay time limitation in accordance with Section 105.3.2 of the State of Oregon, Structural Specialty Code, 2004 edition. If the permit has not been issued within the time limitations referenced in section 105.3.2, the work shall be considered abandoned and the plans will be expired. Respectfully, ./ • Dan Nelson, Senior Plans Examiner Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 ■ Nicoli Engineering, Inc. PO Box 23784 Ti - Tigard, Oregon 97281 • Phone: (503) 620 -2086 • Fax: (503) 684 3636 April 11, 2007 NEI# 07 -0111 City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 Fit IVrD Attn: Dan Nelson, Senior Plans Examiner APR 12 2007 Re: Harris - McMonagle Headquarters CHI or iltjtW j BT1 'rtyrk Tl11rTgrfl Project Information Building Permit: BUP2006 -00493 Tenant Name: Harris - McMonagle Address: 8740 SW Scoffins St Area: 7500 S.F. Mr. Nelson: We have revised our documents per your review. Changes have been noted with a "cloud" and a Delta 1. The following numbered responses correspond to your numbered review comments. There are some general revisions requested by the client and /or contractor. These are minor, but we have included them with this review cycle. These minor changes have also been noted with a "Cloud" and a Delta 1. General Revisions: A. Sheet 2.1, Main Floor Plan A note has been added stating that the HVAC for the Harris - McMonagle office may be located in either the electrical /computer room or the copy, layout, and storage room. B. Sheet 2.1 Main Floor Plan • A portion of the "jo in the southern corridor wall has been removed (adjacent to the 3 office from the east). C. Sheet 2.1 Main Floor Plan The entrance opening from the corridor to the copy layout and storage room has been narrowed. X:L1-070111 Scoffins Street LLC - Harris McMonagle New Buitding\Letters \Response to City Plan Review 041107.doc Page 1 of 2 9025 SW Center Street Tigard, OR 97223 — www.nicoliengineering.com I , ` i, D. Sheet 2.1 Lower Floor Plan The south wall of the exit enclosure has been shifted to the North to allow for more leaseable space. E. Sheet 2.5 The electrical outlet plan has been added to this sheet. City Review Response: 1. See Sheet 2.1: Please let us know if additional information is required. 2. Energy code calculations have been enclosed. Specific requirements are noted on Sheet 1.1, Energy Code Note, and Sheet 4.1 3. Correct: Bidder designed — see added Deferred /Builder Designed Submittal Notes on Cover Sheet. 4. Trusses and manufactured floor joist will be deferred submittals. This requirement is noted on Cover Sheet, Deferred /Bidder Designed submittal notes. 5. Documents prepared by Nicoli Engineering, Inc. are submitted wet stamped and signed. 6. See Sheet 2.1 for area of rescue assistance location. 7. See 2B/5.2 for Rated Corridor Assembly: The callouts /notes in the plans have been changed to reflect this modification. If you have any further comments or questions, please advise. Respectfully Submitted, Jim Andrews JDA:dhl enc X:U -070111 Scoffins Street LLC - Harris McMonagle New Building \Letters \Response to City Plan Review 041107.doc Page 2 of 2 cis • November 2, 2006 Scoffins Property, LLC Attn. Bill McMonagle 12555 SW Hall Blvd. Tigard, OR 97223 RE: HARRIS- MCMON.AGLE HEADQUARTERS Project Information Building Permit: BUP2006 -00493 Construction Type: 5B Tenant Name: Harris - McMonagle Occupancy Type: B Address: 8740 SW Scoffins St. Occupant Load: ? Area: 7500 sq ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition and 2004 Oregon Fire Code as amended by TVF&R. The submitted plans are approved subject to the following conditions. This plan review was done under the assumption of a type 5B, non - sprinkled, `B" occupancy building. If the code summary requested in plan review item # 1 below changes these assumptions, many of the review comments may need to be modified or eliminated and new items may arise. 1. Please provide a code summary for the proposed building. 106.1.1 2. The construction documents shall show a complying means of egress and designate the number of occupants to be accommodated on every floor, and in all rooms and spaces per 106.1.2. Please provide occupant loads for such. 3. The construction documents shall provide details for the exterior wall envelope including , flashing, intersections with dissimilar materials, corners, end details ,control joints, intersections at roof, eaves or parapets, means of drainage, water resistive membrane and details around openings. The documents shall also include all manufacturers' installation instructions that support the requirement that the weather resistance of the exterior envelope is maintained per 106.1.3. Please provide these details and supporting' documents. 4. The site plan shows the Northwest wall of the structure to located 5' from the property line. From table 602, 1 -hour fire resistive construction is required for "B" occupancy of type 5B construction with a fire separation distance of less than 10'. Please indicate the required . firewall on the plans and provide the assembly to be used. 5. A parapet is required for the wall as described in plan review item #4 above by section 704.11. Please provide details for the parapet or plans complying with the exceptions of 704.11. ki v 6. Openings are shown on the Northwest wall of building with a fire separation distance of 5'. Unprotected openings are not permitted within a fire separation distance of 5' or less per table 704.8. Please revise plans to comply with the allowable area of openings in section 704.8. 7. Table 906.3.(1) of the Fire Code requires (2) type 2 -A fire extinguishers on each floor with a maximum travel distance to an extinguisher of 75'. Please provide the location of the extinguishers on the plans. 8. The stairway serving as the required second exit from the upper level is required to be of 1- hour rated construction per section 1019. Please identify the stairway as a 1- hour exit enclosure and terminating at a point of exit discharge. Please provide the fire resistive assembly to be used or demonstrate an alternate code complying exit strategy. 9. The lower floor exceeds the allowable common path of travel and thus requires (2) exits which must be separated by '/2 the diagonal of the building per 1014.2.1. Please provide plans showing the minimum exit or exit access doorway separation. 10. The exit access corridor on the upper level is required to of 1 -hour fire resistive construction for a non - sprinkled `B" occupancy building of 5B construction per section 1016.1. Please indicate the required fire partitions on the plans and provide the assembly to be used. 11. The plans do not provide details for the stair way. Please provide stairway, handrail, and guardrail details complying with sections 1009 and 1012. 12. The plans indicate ADA compliant bathrooms. Please provide details for all accessible fixtures, grab bars, and hardware complying with OSSC chapter 11. 13. The plans do not identify door and window sizes and types. Please provide door and glazing schedules on the plans. 106.1.1 14. The plans do not indicate interior finishes complying with section 806 for flame spread and smoke - development requirements. Please indicate or note finishes on plans. 15. Please provide energy calculation documents per chapter 13. 16. The plans do not indicate an accessible route to the public way from both levels of the building. Section 1108.3 requires an elevator in the proposed building as shown. Please provide plans indicating the location of the elevator and provide details showing code compliance for all requirements pertaining to such or demonstrate how the exceptions to the requirements of section 1108.3 can be met. 17. The following items are not included in the submitted documents: mechanical plans, electrical plans, and plumbing plans and were not reviewed under this permit • 18. The engineered truss details and manufactured floor framing layouts and installation instructions are not included in the submitted documents. Please indicate if these documents are to be submitted for review at this time or indicate if to be deferred submittals. 19. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in casesl where the exit or the path of egress travel is not immediately visible to the occupant per section 1011.1. Please indicate the location of exit signage on the plans. 20. Please provide construction and connection details for the staircase. 106.1.1 Deferred Items: The minimum fee shall be $200.00. This fee is in addition to the project plan review fee based on the total project value. OAR 918- 050 -0150 `Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and been found to be in general conformance to the design of the building. The deferred submittal items shall not be installed until the design and submittal documents have been approved by the building official. Oregon Structural Specialty Code Section 106.3.4.2" • When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, • • Mark VanDomelen, Plans Examiner P . '11 City of Tigard, Oregon • 13125 SWHall Blvd. • Tigard, OR 97223 i • April 2, 2007 - ; T I GARD Scoffins Property, LLC Attn. Bill McMonagle 12555 SW Hall Blvd. Tigard, OR 97223 RE: HARRIS - MCMONAGLE HEADQUARTERS Project Information Building Permit: BUP2006 -00493 Construction Type: 5B Tenant Name: Harris - McMonagle Occupancy Type: B Address: 8740 SW Scoffins St. Occupant Load: 46 Area: 7500 sq ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition and 2004 Oregon Fire Code as amended by TVF&R. The submitted plans are approved subject to the following conditions. This plan review was done under the assumption of a type 5B, non - sprinkled, `B" occupancy building. If the code summary requested changes these assumptions, many of the review comments may need to be modified or eliminated and new items may arise. 1. The plans do not identify door and window sizes and types. Please provide door and glazing schedules on the plans. 106.1.1 2. Please provide energy calculation documents per chapter 13. 3. The following items are not included in the submitted documents: mechanical plans, electrical plans, and plumbing plans and were not reviewed under this permit 4. The engineered truss details and manufactured floor framing layouts and installation instructions are not included in the submitted documents. Please indicate if these documents are to be submitted for review at this time or indicate if to be deferred submittals. 5. The submitted architectural drawings are required to be stamped and hand signed per ORS 672.020. Please provide two stamped sets of drawings. 6. Please provide details of the area of rescue assistance required at the main floor in lieu of the two required exits. (OSSC 1107.1) 7. Provide listing for one hour corridor interior walls. Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 • FIRE LIFE AND SAFETY / GENERAL The main exterior door or doors are permitted to be equipped with key - operated locking devices from the egress side provided: 1. The locking device is readily distinguishable as locked, 2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating. THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background. Sec. 1008.1.8.3 All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Sec. 1008.1.8 Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Sec. 1011.1 Exit signs shall be illuminated at all times and shall be provided with a second source of power that will provide 1 1/2 hours of illumination in case of primary power loss. Sec. 1006.3 FYI Additional exit signs may be required by the city field inspector to clearly indicate the path of egress. The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level anytime the building is occupied. The means of egress illumination shall be provided with a second source of power in case of primary power loss. Sec. 1006.2 All elevators, required or provided, shall be located on an accessible route and shall be designed and constructed to comply with Chapter 30 and the Oregon Elevator Specialty Code. 1108.3.2 OSSC • Floor drains shall not be located within the clear floor space at a lavatory, water closet, urinal, or bathtub or shower. Floors shall not slope in excess of 1 unit vertical in 50 units horizontal (2 % slope). Floor drains shall comply with Section 1109.4.5 and be without abrupt changes of level. Exception: Floor drains may be located within a clear floor space at a fixtusr provided the openings in the drain cover shall not exceed %2 inch (12.7 mm) in any direction and the drain cover shall be no more than 1 / 8 inch below the level of the surrounding finished floor suface. 1109.10.1 OSSC Safety glazing including but not limited to: the following locations: Each unit of glazing shall be permanently identified by the manufacturer. Sec. 2406. Some of these locations are as follows: a. Glazing in ingress and means of egress doors. b. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24" arc of the door in a closed position and whose bottom edge is less than 60" above the floor or walking surface except when there is an intervening wall or other permanent barrier between the door and the glazing. Live Loads Posted: The live loads for which each floor has been designed to exceed 50 psf shall be conspicuously posted by the owner in that part of each story in which they apply, using durable metal signs, and it shall be unlawful to remove or deface such notices. The occupant of the building shall be responsible for keeping the actual load below the allowable limits. 1603.3 OSSC Deferred Items: The minimum fee shall be $200.00. This fee is in addition to the project plan review fee based on the total project value. OAR 918 - 050 -0150 "Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and been found to be in general conformance to the design of the building. The deferred submittal items shall not be installed until the design and submittal documents have been approved by the building ofciaL Oregon Structural Specialty Code Section 106.3.4.2" • American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 109.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. . When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of TransmittaL The letter of transmittal assists the City of Tigard in tracking and processing the documents. l .espectfully, \' l elson, Senior Plans Examiner • City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 April 2, 2007 • T I GARD Scoffins Property, LLC Attn. Bill McMonagle 12555 SW Hall Blvd. Tigard, OR 97223 RE: HARRIS - MCMONAGLE HEADQUARTERS Project Information Building Permit BUP2006 -00493 Construction Type: 5B Tenant Name: Harris - McMonagle Occupancy Type: B Address: 8740 SW Scoffins St. Occupant Load: 46 Area: 7500 sq ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition and 2004 Oregon Fire Code as amended by TVF&R. The submitted plans are approved subject to the following conditions. This plan review was done under the assumption of a type 5B, non - sprinkled, `B" occupancy building. If the code summary requested changes these assumptions, many of the review comments may need to be modified or eliminated and new items may arise. 1. The plans do not identify door and window sizes and types. Please provide door and glazing schedules on the plans. 106.1.1 Cr__ 2. Please provide energy calculation documents per chapter 13.- 3. The following items are not included in the submitted documents: mechanical plans, electrical plans, and plumbing plans and were not reviewed under this permit 6 4. The engineered truss details and manufactured floor framing layouts and installation instructions are not included in the submitted documents. Please indicate if these documents are to be submitted for review at this time or indicate if to be deferred submittals. 12.3 RYscr 5. The submitted architectural drawings are required to be stamped and hand signed per ORS 672.020. Please provide two stamped sets of drawings. 644_ 6. Please provide details of the area of rescue assistance required at the main floor in lieu of the two required exits. (OSSC 1107.1) Oa- "el- 7. Provide listing for one hour corridor interior walls. Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 FIRE LIFE AND SAFETY / GENERAL The main exterior door or doors are permitted to be equipped with key - operated locking devices from the egress side provided: 1. The locking device is readily distinguishable as locked, • 2. A readily visible durable sign is posted on the egress side on or adjacent to the door • stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background. Sec. 1008.1.8.3 All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Sec. 1008.1.8 Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Sec. 1011.1 Exit signs shall be illuminated at all times and shall be provided with a second source of power that will provide 1 '/Z hours of illumination in case of primary power loss. Sec. 1006.3 FYI Additional exit signs may be required by the city field inspector to clearly indicate the path of egress. The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level anytime the building is occupied. The means of egress illumination shall be provided with a second source of power in case of primary power loss. Sec. 1006.2 • All elevators, required or provided, shall be located on an accessible route and shall be designed and constructed to comply with Chapter 30 and the Oregon Elevator Specialty Code. 1108.3.2 OSSC Floor drains shall not be located within the clear floor space at a lavatory, water closet, urinal, or bathtub or shower. Floors shall not slope in excess of 1 unit vertical in 50 units horizontal (2 % slope). Floor drains shall comply with Section 1109.4.5 and be without abrupt changes of level. Exception: Floor drains may be located within a clear floor space at a fixture provided the openings in the drain cover shall not exceed %z inch (12.7 mm) in any direction and the drain cover shall be no more than 1/8 inch below the level of the surrounding finished floor su 1109.10.1 OSSC Safety glazing including but not limited to: the following locations: Each unit of glazing shall be permanently identified by the manufacturer. Sec. 2406. Some of these locations are as follows: a. Glazing in ingress and means of egress doors. b. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24" arc of the door in a closed position and whose bottom edge is less than 60" above the floor or walking surface except when there is an intervening wall or other permanent barrier between the door and the glazing. • Live Loads Posted: The live loads for which each floor has been designed to exceed 50 psf shall be conspicuously posted by the owner in that part of each story in which they apply, using durable metal signs, and it shall be unlawful to remove or deface such notices. The occupant of the building shall be responsible for keeping the actual load below the allowable limits. 1603.3 OSSC Deferred Items: The minimum fee shall be $200.00. This fee is in addition to the project plan review fee based on the total project value. OAR 918 - 050 -0150 `Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and been found to be in general conformance to the design of the building. The deferred submittal items shall not be installed until the design and submittal documents have been approved by the building off cial Oregon Structural Specialty Code Section 106.3.4.2" American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 109.1 OSSC • Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. • When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. V _ ¶espectfully, 0 40 "1"1".'if • elson, Senior Plans Examiner • TRANSMISSION VERIFICATION REPORT TIME : 04/02/2007 10:45 NAME : TIGARD BUILDING DEPT FAX : 5036243681 TEL . SER.# : BROD4J479592 DATE, TIME 04/02 10:44 FAX NO. /NAME 5036843636 DURATION 00: 01:04 PAGES) 04 RESULT OK MODE STANDARD ECM xm•a - try °B'li'nd\ " \ "rrmraV d - S.efuevi.i !Radss3w - 7 (QLL- © � :Jaatgns izsz'8 Y L. £U5 xld i89£17C9 £US t #• • cA9S +0,. a :# x�e3 s .LJO .J "O0 - I ��G771 :op City of Tigard 1111 13125 SW Hall Blvd. , Tigard, OR 97223 • Phone: 503 - 639 -4171 T I GARD FAx TRANSMITTAL Date 4/2 L �? Number of pages including cover sheet To: .: From: Dan Nelson Co: M / COZ- P Co: Ci a ty of Tigrd Fax #: ' . 6 84- Fax #: 503.624.3681 Ph #: 503.718.2423 SUBJECT: MESSAGE: 4A 414C AC ITS # 7 " . [: \ Building \Forms \FaxTransmittal -P.doc 1/18/07