Loading...
Plans 1. C314 ea007 - 0 0 35/ 3 tLJCcl Fire & Building Products CENTRAL Customer ice /Sales: Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Tel: (215) 362 -0700 / (800) 523 -6512 Fax: (215) 362 -5385 Series TY -B — 2.8, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage obtained by utilizing the Series TY -B General Pendent Sprinkler in combination with Description the Model S2 Shield WARNINGS .',e The Series TY-B, 2.8, 5.6, and 8.0 The Series TY -8 Sprinklers described Upright and Pendent Sprin- herein must be installed and main- a klers described in this data sheet are tained in compliance with this docu- I , .r standard response - standard cover- ment, as well as with the applicable age, decorative 5 mm glass bulb type standards of the National Fire Protec- spray sprinklers designed for use in tion Association, in addition to the light, ordinary, or extra hazard, corn- standards of any other authorities hay- --- mercial occupancies such as banks, ing jurisdiction. Failure to do so may `" - hotels, shopping malls, factories, refin- impair the integrity of these devices. eries, chemical plants, etc. The owner is responsible for maintain - The recessed version of the Series ing their fire protection system and de- ��i lib.... TY-B Pendent Sprinkler, where appli- vices in proper operating condition. cable, is intended for use in areas with The installing contractor or sprinkler _ a finished ceiling. It uses a two -piece manufacturer should be contacted �. Style 10 (1/2 inch NPT) or Style 40 (3/4 relative to any questions. 71/. vz - ..N\ • inch NPT) Recessed Escutcheon. The f Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of Model/Sprinkler 4- ,f total adjustment from the flush pen- p dent position. The adjustment provided Identification __, by the Recessed Escutcheon reduces the accuracy to which the fixed pipe Numbers °r — drops to the sprinklers must be cut. Corrosion resistant coatings, where TY1151 - Upright 2.8K, 1/2"NPT Discharge Coefficient applicable, are utilized to extend the TY1251 - Pendent 2.8K, 1/2 "NPT K = 2.8 GPM /psil' (40,3 LPM/bar life of copper alloy sprinklers beyond TY3151 - Upright 5.6K, 1/2 "NPT K = 5.6 GPM /psi (80,6 LPM /bar that which would otherwise be ob- TY3251 - Pendent 5.6K, 1/2"NPT K = 8.0 GPM /psi " (115,2 LPM /bar" " tained when exposed to corrosive at- TY4151 - Upright 8.0K, 3/4 "NPT mospheres. Although corrosion resis- TY4251 - Pendent 8.0K, 3/4 "NPT Temperature Ratings tant coated sprinklers have passed the TY4851 - Upright 8.0K, 1/2"NPT Refer to Table A standard corrosion tests of the appli- TY4951 - Pendent 8.0K, 1/2 "NPT Finishes cable approval agencies, the testing is Sprinkler: Refer to Table A not representative of all possible cor- Technical Recessed Escutcheon: White Coated, rosive atmospheres. Consequently, it Chrome Plated, or Brass Plated is recommended that the end user be Y consulted with respect to the suitability Data Physical Characteristics of these coatings for any given corro- Frame Bronze E sive environment. The effects of ambi Approvals Button Brass /Copper 0 ent temperature, concentration of UL and C -UL Listed. Sealing Assembly chemicals, and gas /chemical velocity, FM, LPCB, and NYC Approved. Beryllium Nickel w/Teflont should be considered, as a minimum, (Refer to Table A for complete approval Bulb Glass iii along with the corrosive nature of the information including corrosion resis- Compression Screw Bronze N cu chemical to which the sprinklers will be tant status.) Deflector Copper ex exposed. Bushing o: P Maximum Working Pressure 9 (K =2.8) Bronze E An intermediate level version of the 175 psi (12,1 bar) a Series TY-B Pendent Sprinkler can be o ' Page 1 of 8 JANUARY, 2003 TFP151 „ ,,, , 4 Page 2 of 8 TFPI51 ESCUTCHEON 7/16” (11,1 mm) PLATE SEATING ** NOMINAL SSU SURFACE NPT MAKE -IN DEFLECTOR - - - _ 6 1 ifr r ^ - 94 1 a 0,11 CTT IQ,' 5 2.1/4" f (57,2 mm) A 1 (55,6 m) 4 1 -9/16 WRENCH . rill 1.11E1 hA (39.7 mm) FLATS '� 3 ��r.��� sue. • SSP 7 DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 • Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. • FIGURE 1 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 10 PLATE SEATING * * NOMINAL RECESSED SURFACE NPT MAKE -IN ESCUTCHEON SSU* — DEFLECTOR 6 k;i iiT zN � 7/16° f�. 5 2.3/16" �c 1o1' —� M (11,1 mm) ` MAKE -IN I I 1.112° 4 � �� � i. (55,6 mm) '� (38,1 mm) I �� � 2.3/16° ,0 2 (55,6 mm) 9 _ � _ _ WRENCH i 3 ' _ ' -%• : A ..._. FLATS --- — 1 # Q • 1 SSP DEFLECTOR * 4— 2 -7/8° (73,0 mm) DIA. ----J 1/2• NPT I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT TFP151 Page 3 of 8 ESCUTCHEON 1/2° (12,7 mm) STYLE 40 PLATE SEATING ** NOMINAL RECESSED SURFACE NPT MAKE -IN ESCUTCHEON SSU* - - DEFLECTOR / 6 * i / ;M 1/2' ' 5 2 -5/16° ' (12,7 mm) (58,7 mm) 7 NOMINAL i I 4 t =_— MAKE IN , 1 9/16" V �� 11.� 2 1/4• Id 2 (39,7 mm) WRENCH '� (57,2 mm) �' 3 1 • ----° .._. • ___ FLATS = 7:( 1 SSP DEFLECTOR * f— 2 -7/8° (73,0 mm) DIA. 3/4 NPT" } PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Ejection orifice seat on frame. Screw Spring ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT ESCUTCHEON 7/16' (11,1 mm) PLATE SEATING 1/2 ** NOMINAL SSU` SURFACE NPT MAKE -IN DEFLECTOR =� e' ;r- — — 7i'�'e!� ::'TT,�p'ITfd * r I �� � �' 5 (57,2 mm) 2 -1/4" 2- 3/16" dIL� 6 mm) ' A ( 55, 4 i l i I 1-9/16° WRENCH '! —I/ � (39,7 mm) FLATS Y 7 1 f 3 SSP 1 DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K- FACTOR, 1/2 INCH NPT • Page 4 of 8 TFP151 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL CHROME WHITE'•' LEAD WAX WAX OVER LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135'Fi57 °C Orange PENDENT 155'F /68 °C Red 2.8 (TY1251) 1, 2, 3 1/2° and 175'F/79 °C Yellow N/A NPT UPRIGHT 200 °F /93 °C Green (TY1151) 286 °F /141 °C Blue 360F/i82°C Mauve 1, 2 135'F/57 °C Orange PENDENT 155'F /68 °C Red (TY3251) 1, 2, 3, 4, 5, 6 1, 2, 3, 5 1, 2, 3, 5 1, 2, 3, 5 and 175'F/79 °C Yellow UPRIGHT 200'F/93 °C Green 5.6 (TY3151) - 286 °F /141 °C Blue 1 °• 2°° 3 °• 5°° 1 1 °° 2 ", 3••, 5" 1/2° NPT 360 °F /182 °C Mauve N/A 135'F/57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 5 1, 2, 5 N/A (TY3251)• 175 °F /79 °C Yellow Figure 4 200 °F /93 °C Green 135'F/57 °C Orange PENDENT 155 °F /68 °C Red (TY4251) and 175 °F /79 °C Yellow 1, 2, 5 1, 2, 3, 5 1, 2, 5 UPRIGHT 1, 2, 3, 4, 5, 6 8.0 (TY4151) 200 °F /93 °C Green 3/4° 286 °F /141'C Blue 1°°,2° °, 3•°, 59 1••, 2••, 5" NPT 360 °F /182 °C Mauve N/A 135'F/57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1 2, 3, 5 N/A (TY4251)• 175'F/79 °C Yellow Figure 5 200 °F /93 °C Green 135 °F /57 °C Orange PENDENT 155'F/68 °C Red 8.0 (TY4951) 1/2° and 175'F/79 °C Yellow 1, 2, 3, 5 N/A NPT UPRIGHT 200 °F /93 °C Green (TY4851), 286 °F /141 °C Blue 360 °F /182 °C Mauve NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB). 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31- 53- 428- 4444/Fax 31 -53- 428 - 3377). 7. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. • Installed with Style 10 (1/2° NPT) or Style 40 (3/4° NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. •' 150 °F /66 °C Maximum Ceiling Temperature. '•' Frame and deflector only. Listings and approvals apply to all colors (Special Order). N /A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS • TFP151 Page 5 of 8 2 -7/8" DIA. 5/81-1/4" (73,0 mm) 3/4" (19,1 mm) (15,9 ±6,4 mm) 2 1/4" DIA. 1/4" (6,4 mm) WRENCH RECESS FACE OF (57,2 mm) MOUNTING ( 1 2 D NPT MODELS) SPRINKLER PLATE FITTING 1/8" WRENCH RECESS m' (3,2 mm) (END 'B' USED FOR 3/4' NPT MODELS) FIGURE 7 I� , W -TYPE 6 SPRINKLER J 1 WRENCH MOUNTING PI SURFACE WRENCH CLOSURE SERIES 1 -1/4" (31,8 mm) RECESS TY -B 3/4" (19,1 mm) a FIGURE 5 SERIES TY -B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT PUSH WRENCH IN TO ENSURE 2 -7/8" DIA. ENGAGEMENT (73,0 mm) 3/4" (19,1 mm) WITH SPRINKLER 5/8±1/4" WRENCHING AREA (15,9±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (57,2 mm) FIGURE 8 FACE OF MOUNTING W-TYPE 7 RECESSED SPRINKLER PLATE SPRINKLER WRENCH FITTING 1/8" (3,2 mm) -: rD : I Operation ; I The glass Bulb contains a fluid which MOUNTING } expands when exposed to heat. When SURFACE the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to CLOSURE SERIES 1- 5/16" (33,3 mm) activate and water to flow. TY -B 13/16" (20,6 mm) Design FIGURE 6 Criteria SERIES TY -B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT The Series TY B Pendent and Upright STYLE 40 RECESSED ESCUTCHEON Sprinklers are intended for fire protec- 8.0 K- FACTOR, 3/4 INCH NPT tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Page 6 of 8 TFP151 ing the wax coating. Before wrench stalled or the finish coat has been ap- Installation tightening the sprinkler, the jaws of the plied, slide on the Style 10 or 40 Clo- wrench are to be adjusted to just con- sure over the Series TY -8 Sprinkler The Series TY -B Sprinklers must be tact the sprinkler wrench flats. After and push the Closure over the Mount - installed in accordance with the follow- wrench tightening the sprinkler, loosen ing Plate until its flange comes in con- ing instructions: the wrench jaws before removing the tact with the ceiling. wrench. NOTES Do not install any bulb type sprinkler if After installation, the sprinkler wrench the bulb is cracked or there is a loss of flats and frame arms must be in- liquid from the bulb. With the sprinkler spected and the wax coating re- held horizontally, a small air bubble touched (repaired) whenever the coat - should be present. The diameter of the ing has been damaged and bare metal . air bubble is approximately 1/16 inch is exposed. The wax coating on the (1,6 mm) for the 135 °F /57 °C to 3/32 wrench flats can be retouched by gen- inch (2.4 mm) for the 360 °F /182'C tly applying a heated 1/8 inch diameter temperature ratings. steel rod to the areas of wax that have been damaged, to smooth it back over A leak tight 1/2 inch NPT sprinkler joint areas where bare metal is exposed. should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- NOTES mum of 21 ft. lbs. (28,5 Nm) of torque Only retouching of the wax coating ap- may be used to install sprinklers with plied to the wrench flats and frame 1/2 NPT connections. A leak tight 3/4 arms is permitted, and the retouching inch NPT sprinkler joint should be ob- is to be performed only at the time of tained with a torque of 10 to 20 ft.lbs. the initial sprinkler installation. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used The steel rod should be heated only to to install sprinklers with 3/4 NPT con- the point at which it can begin to melt nections. Higher levels of torque may the wax, and appropriate precautions distort the sprinkler inlet and cause need to be taken, when handling the leakage or impairment of the sprinkler. heated rod, in order to prevent the installer from being burned. Do not attempt to make -up for insuffi- cient adjustment in the escutcheon If attempts to retouch the wax coating . plate by under- or over - tightening the with complete coverage are unsuc- sprinkler. Readjust the position of the cessful, additional wax can be ordered sprinkler fitting to suit. in the form of a wax stick (the end of which is color coded). Only the correct The Series TY -B Pendent and Up- color coded wax is to be used, and right Sprinklers must be installed in retouching of wrench flats and frame accordance with the following instruc- arms is only permitted at the time of tions. initial sprinkler installation. With • the Step 1. Pendent sprinklers are to be steel rod heated as previously de- installed in the pendent position, and scribed, touch the rod to the area re- upright sprinklers are to be installed in quiring additional wax with the rod an the upright position. gled downward, and then touch the wax stick to the rod approximately Step 2. With pipe thread sealant ap- one -half inch away from the area re- plied to the pipe threads, hand tighten quiring retouching. The wax will melt the sprinkler into the sprinkler fitting. and run down onto the sprinkler. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type The Series TY -B Recessed Pendent 6 Sprinkler Wrench (Ref. Figure 7), Sprinklers must be installed in ac- except that an 8 or 10 inch adjustable cordance with the following instruc- Crescent wrench is to be used for wax tions. coated sprinklers. With reference to Figures 1, 2, 3, and 4 the W -Type 7 Step A. After installing the Style 10 or Sprinkler Wrench or the adjustable 40 Mounting Plate, as applicable, over Crescent wrench, as applicable is to the sprinkler threads and with pipe be applied to the wrench flats. thread sealant applied to the pipe threads, hand tighten the sprinkler into When installing wax coated sprinklers the sprinkler fitting. with the adjustable Crescent wrench, additional care needs to be exercised Step B. Tighten the sprinkler into the to prevent damage to the wax coating sprinkler fitting using only the W -Type on the sprinkler wrench flats or frame 7 Recessed Sprinkler Wrench (Ref. arms and, consequently, exposure of Figure 8). With reference to Figure 3 or bare metal to the corrosive environ- 4, the W -Type 7 Recessed Sprinkler ment. The jaws of the wrench should Wrench is to be applied to the sprinkler be opened sufficiently wide to pass wrench flats. over the wrench flats without damag- Step C. After the ceiling has been in- TFP151 Page 7 of 8 are and addition to the standards . any other Limited authorities having jurisdiction. The e in- stalling contractor or sprinkler manu- w arranty Maintenance facturer should be contacted relative to • Sprinklers must be any questions. The Series TY -B S P Products manufactured by Tyco Fire maintained and serviced in accord- It is recommended that automatic Products are warranted solely to the ance with the following instructions: sprinkler systems be inspected, original Buyer for ten (10) years tested, and maintained by a qualified against defects in material and work - NOTES Inspection Service. manship when paid for and properly Before closing a fire protection system installed and maintained under normal main control valve for maintenance use and service. This warranty will ex- work on the fire protection system that pire ten (10) years from date of ship - it controls. permission to shut down the ment by Tyco Fire Products. No war- affected fire protection system must be ranty is given for products or obtained from the proper authorities components manufactured by compa- and all personnel who may be affected nies not affiliated by ownership with by this action must be notified. Tyco Fire Products or for products and Absence of an escutcheon, which is components which have been subject used to cover a clearance hole, may to misuse, improper installation, corro- delay the time to sprinkler operation in sion, or which have not been installed, a fire situation. maintained, modified or repaired in ac- cordance with applicable Standards of Sprinklers that are found to be leaking the National Fire Protection Associa- or exhibiting visible signs of corrosion tion, and /or the standards of any other must be replaced. Authorities Having Jurisdiction. Mate - Automatic sprinklers must never be vials found by Tyco Fire Products to be painted, plated, coated or otherwise defective shall be either repaired or altered after leaving the factory. Modi- replaced, at Tyco Fire Products' sole Pied sprinklers must be replaced. option. Tyco Fire Products neither as Sprinklers that have been exposed to sumes, nor authorizes any person to corrosive products of combustion, but assume for it, any other obligation in have not operated, should be replaced connection with the sale of products or if they cannot be completely cleaned parts of products. Tyco Fire Products by wiping the sprinkler with a cloth or shall not be responsible for sprinkler by brushing it with a soft bristle brush. system design errors or inaccurate or incomplete information supplied by Care must be exercised to avoid dam- Buyer or Buyer's representatives. age to the sprinklers - before, during, IN NO EVENT SHALL TYCO FIRE and after installation. Sprinklers dam- PRODUCTS BE LIABLE, IN CON - aged by dropping, striking, wrench TRACT, TORT, STRICT LIABILITY OR twist/slippage, or the like, must be re- UNDER ANY OTHER LEGAL THE - placed. Also, replace any sprinkler that ORY, FOR INCIDENTAL, INDIRECT, has a cracked bulb or that has lost SPECIAL OR CONSEQUENTIAL liquid from its bulb. (Ref. Installation DAMAGES, INCLUDING BUT NOT Section). LIMITED TO LABOR CHARGES, RE- Frequent visual inspections are rec- GARDLESS OF WHETHER TYCO ommended to be initially performed for FIRE PRODUCTS WAS INFORMED corrosion resistant coated sprinklers, ABOUT THE POSSIBILITY OF SUCH after the installation has been corn- DAMAGES, AND IN NO EVENT pleted, to verify the integrity of the cor- SHALL TYCO FIRE PRODUCTS' Ll- rosion resistant coating. Thereafter, ABILITY EXCEED AN AMOUNT annual inspections per NFPA 25 EQUAL TO THE SALES PRICE. should suffice; however, instead of in- THE FOREGOING WARRANTY IS specting from the floor level, a random MADE IN LIEU OF ANY AND ALL, sampling of close-up visual inspec OTHER WARRANTIES EXPRESS OR lions should be made, so as to better IMPLIED. INCLUDING WARRANTIES determine the exact sprinkler condi- OF MERCHANTABILITY AND FIT - tion and the long term integrity of the MESS FOR A PARTICULAR PUR- corrosion resistant coating, as it may POSE, be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in • Page 8 of 8 TFP151 P/N 57 -XXX -X -XXX I I TEMPERATURE MODEUSIN RATING SPRINKLER 530 2.8K UPRIGHT (1/2 "NPT) TY1151 135 135 °F /57 °C 531 2.8K PENDENT (1/2 °NPT) TY1251 1 NATURAL BRASS 155 155 °F /68 °C 570 5.6K UPRIGHT (1/2 "NPT) TY3151 4 WHITE POLYESTER 175 175 °F /79 °C 571 5.6K PENDENT (1/2 "NPT) TY3251 9 CHROME PLATED 200 200 °F /93 °C 590 8.0K UPRIGHT (3/4 "NPT) TY4151 7 LEAD COATED 286 286 °F /141'C 591 8.0K PENDENT (3/4 °NPT) TY4251 6 WAX COATED 360 360 °F /182 °C 286 °F /141 °C MAX. - 560 8.0K UPRIGHT (1/2 °NPT) TY4851 8 WAX OVER LEAD 561 8.0K PENDENT (1/2 "NPT) TY4951 286'F/141 °C MAX. TABLE B PART NUMBER SELECTION SERIES TY -B PENDENT AND UPRIGHT SPRINKLERS Recessed Escutcheon: Wax Sticks: Ordering Specify: Style (specify) Recessed Es- (for retouching wrench damaged cutcheon with (specify finish), P/N wax coating) Procedure (specify). Specify: (Specify color) color coded When placing an order, indicate the full 1/2' (15 mm) Wax Stick for retouching (specify tern- product name. Refer to the Price List Style 10 perature rating) temperature rated Se- for complete listing of Part Numbers. Chrome Plated P/N 56 -701 -9 -010 ries TY B Sprinklers, P/N (specify). 1/2' (15 mm) Contact your local distributor for avail- Style 10 Black for 135 °F P/N 56- 065 -1 -135 ability. White Colo Red for 155 °F P/N 56-065-1-155 Coated P/N 56-701-4-010 Yellow tor 175°F P/N 56-065-1-175 1/2' (15 mm) Blue for 200 °F and Sprinkler Assemblies with NPT Style 10 Thread Connections: Brass Plated P/N 56.701 -2 -010 286°F P/N 56-065-1-286 Specify: (Specify Model /SIN), Stand- 3/a° (20 mm) and Response, (specify K-factor), Style 40 NOTES Chrome Plated P/N 56 Each wax stick is suitable for retouch - (specify temperature rating), Series 3/4° (20mm) TY -B (specify Pendent or Upright) Style 40 ing up to twenty-five sprinklers. Sprinkler with (specify type of finish or White Color The wax used for 286 °F sprinklers is coating), P/N (specify from Table B). Coated P/N 56.700 -4 -010 the same as for 200 °F sprinklers, and, 3/4' (20 mm) therefore, the 286 °Fsprinkler islimited Style 40 Brass Plated P/N 56- 700 -2 -010 to the same maximum ceiling tempera- ture as the 200 °F sprinkler (i.e., Sprinkler Wrench: 150 °F). Specify: W -Type 6 Sprinkler Wrench, P/N 56- 000 -6 -387. Specify: W -Type 7 Sprinkler Wrench, P/N 56- 850 -4 -001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446