Plans ;> • / / i FIRE RESISTANCE DIRECTORY r I OU Pa�a e 17 758 FIRE RESISTANCE RATINGS -ANSWL 263 (BXUV) / FIRE RESISTANCE RATINGS • ANSWL 263 (BXUV) 1 -7/8 in. long, bugle -head Type TEK fasteners at each lap. Panels 4A. Gypsum Board'— (As an alternate to Item 4) — 5/8 in. thick lapped minimum 1 in. panels, installed as described in Item 4 with Type S-12 steel screw MASONITE CORP —Type FT length and spacing of the screws as specified under Item 5. 8. Joint Tape and Compound — Vinyl or casein, dry or premixed joint CANADIAN GYPSUM COMPANY —Type FRX compound applied in two coats to joints and screw heads. Perforated UNITED STATES GYPSUM CO —Type FRX paper tape, 22 in. wide, embedded in first layer of compound over all 4B. Gypsum Board*— (As an alternate to Items 4 and 4A) — 5/8 in. joints. thick, 2 ft. wide, tongue and groove edge, applied horizontally as the *Bearing the UL Classification Mark outer layer to one side of the assembly. Secured as described in Items Joint covering (Item 7) not required. Design No. U419 CANADIAN GYPSUM COMPANY — Type SHX. Nonbearing Wall Ratings —1, 2, 3 or 4 Hr (See Items 3 & 4) UNITED STATES GYPSUM CO —Type SHX. USG MEXICO S A DE C V — Type SHX. 5. Fasteners — (Not shown) — Type S or S-12 steel screws used to attach For Number of Layers 0 panels to studs (Item 2) or furring channels (Item 6). Single layer sys. and Hourly Ratings terns: 1 in. long for 1/2 and 5/8 in. thick panels or 1 -1/4 in. long for See Item 4 t— ____I 3/4 in. thick panels, spaced 8 in. OC when panels are applied horizo tally, or 8 in. OC along vertical and bottom edges and 13 in. OC in th ' field when panels are applied vertically. Two layer systems: First layer - i 1 in. long for 1/2 and 5/8 in. thick panels or 1 -1/4 in. long for 3/4 in _ � ' _ thick panels, spaced 16 in. OC. Second layer- 1 -5/8 in. long for 1/2 in., 5/8 in. thick panels or 2 -1/4 in. long for 3/4 in. thick panels, spaced 16 ea) ® in. OC with screws offset 8 in. from first layer.Three -layer systems: 0 0 First layer- 1 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. Oc Second layer- 1 -5/8 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Third layer- 2 -1/4 in. long for 1/2 in., 5/8 in. thick panels or 1. Floor and Ceiling Runners — (Not shown) — Channel shaped, fabri- 2-5/8 in. long for 5/8 in. thick panels, spaced 12 in. OC. Screws offset rated from min 25 MSG (min 20 MSG when Item 4A is used) corrosion- min 6 in. from layer below. Four -layer systems: First layer- 1 in. Ion protected steel, min width to accommodate stud siie, with min 1 in. for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Second layer- l ayer long legs, attached to floor and ceiling with fasteners 24 in. OC max. in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Third layer - 2. Steel Studs — Channel shaped, fabricated from min 25 MSG (min 20 2-1/4 in. long for 1/2 in. thick panels or 2 -5/8 in. long for 5/8 in. thick MSG when Item 4A is used) corrosion- rotected steel, min width as panels, spaced 24 in. OC. Fourth layer- 2 -5/8 in. long for 1/2 in. thick p panels or 3 in. long for 5/8 in. thick panels, spaced 12 in. OC. Screws 4 . indicated under Item 4, min 1 -1/4 in. flanges and 1/4 in. return, spaced offset min 6 in. from layer below. P P a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than assembly 6. Furring Channels (Optional, not shown, for single or double layer height. g (OP g Y 3. Batts and Blankets' — (Required as indicated under Item 4) — Min- systems) — Resilient furring channels fabricated from min 25 MSG ' eral wool baits, friction fitted between studs and runners. Min nom corrosion - protected steel, spaced vertically a max of 24 in. OC. Flange ' thickness as indicated under Item 4. See Batts and Blankets (BKNV or portion attached to each intersecting stud with 1/2 in. long Type 512 steel screws. Not for with Item 4A. BZJZ) Categories for names of Classified companies. use w em w 3A. Batts and Blankets*— (Optional) — Placed in stud cavities, any glass 7. Joint Tape and Compound — Vinyl or casein, dry or premixed joint fiber or mineral wool insulation bearing the UL Classification Marking applied in two coats to joints and screw heads of outer lay - as to Surface Burning Characteristics and /or Fire Resistance. See Batts ers. Pa er tape, nom 2 in. wide, embedded in first layer of compound and Blankets (BKNV or BZJZ) Categories for names of Classified com- over all joints of outer layer panels. Paper tape and joint compound may be omitted when gypsum panels are supplied with a square edge. 4. Gypsum Board*— Gypsum panels with beveled, square or tapered edges, applied vertically or horizontally. Vertical joints centered over 8. Siding, Brick or Stucco — (Optional, not shown) — Aluminum, vinyl a or steel siding, brick veneer or stucco, meeting the requirements of studs and staggered one stud cavity on opposite sides of studs. Vertical local code agencies, installed over gypsum panels. Brick veneer oints in adjacent layers (multilayer systems) staggered one stud cavity. attached to studs with corrugated metal wall ties attached to each stud with steel screws, not more than each sixth course of brick. Horizontal joints need not be backed by steel framing. Horizontal edge 9. Caulking and Sealants*— (Optional, not shown) — A bead of acous- joints and horizontal butt joints on opposite sides of studs need not be tical sealant applied around the partition perimeter for sound control. staggered. Horizontal edge joints and horizontal butt joints in adjacent p layers (multilayer systems) staggered a min of 12 in. The thickness and y UNITED STATES GYPSUM CO —Type AS number of layers for the 1 hr, 2 hr 3 hr and 4 hr atin Bearing the UL Classification Mark I Wallboard Protection on Each Side orf W gs are as follows: all Design No. U420 Rating Min Stud No. of Layers Min Thkns Nonbearing Wall Rating — 1 or 2 HR. Depth & Mims of Panel of Insulation (Item 3) Q l — 24 "o.c. —� f-- 24 "o.c. --{ . ■iilmiN7MINI 1 1 - 1 3-1/2 l layer, 5/8 in. thick Optional 1 2 -5 1-5/8 l layer, 3/4 i /8 1 layer, 3 /4 in. thick 1p ionao ial 5n thick Optil ':".• O Q r7.7-3== -02 I 2 1 -5/8 2 layers, 1 /2 in. thick Optional �� 2 1 -5/8 2 layers, 5/8 in. thick Optional • 2 3-1/2 1 layer, 3/4 in. thick 3 in O HORIZONTAL SECTION 3 1 -5/8 3 layers, 1 /2 in. thick Optional 3 1 -5/8 2layers, 3/4 in. thick Optional O 3 1 -5/8 3 layers, 5/8 in. thick Optional cD -.. l= ti ._ i W s avi 4 1 -5/8 4 layers, 5/8 in. thick Optional j'. Q O© i O © �1 s • 4 1 -5/8 4 layers, 1 /2 in. thick Optional w' � -.7 � 4 2-1/2 2 layers, 3/4 in. thick 2 in " . - e,. a.� -,. sin. _ .LL _ CANADIAN GYPSUM COMPANY -1/2 in. thick Type C, VERTICAL SECTION ' � ` r-,• ' IP -X2 or IPC -AR; WRC, 5/8 in. thick Type AR, C, IP -AR, IP -Xl, ay F. TIGARD t IP -X2, IPC -AR, SCX, SHX, WRX or WRC; 3/4 in. thick Type 1. Studs— Channel — shaped 1 5/8 in. wi r ��� IP -X3, ULTRACODE, ULTRACODE SHC or ULTRACODE in..stiffening flanges. Fabricated from'No. WRC. be cut 1/4 in. less than assembly height. UNITED STATES GYPSUM CO —1/2 in. thick Type C, IP -X2, 2. Bracing — Cut from the steel runners, min. 9-1/2 in. long, fastened IPC -AR or WRC; 5/8 in. thick Type SCX, SHX, WRX, IP -Xl, to the studs with two No. 8 by 1/2 in. long self- drilling, self- tapping AR, C, WRC, FRX-G, IP -AR, 11D-X2 WC-AR; 3/4 in. thick Type steel screws in each stud. As an alternate, but limits the stud cavity IP -X3, ULTRACODE, ULTRACODE SHC or ULTRACODE depth to 9 -1/2 in., cut from the gypsum wallboard, 9 -1/2 in. long and WRC. 12 in. wide, fastened to the studs with three Type S wallboard screws USG MEXICO S A DE C V —1/2 in. thick Type C, IP -X2, in each stud. Vertical spacing of bracing not to exceed 48 in. OC. j IPC -AR or WRC; 5/8 in. thick Type AR, C, IP AR, IP -X1, IP -X2, 3. Floor and Ceiling Runners — Channel — shaped 1 5/8 in. wide with IPC -AR, SIX, SHX, WRX, WRC or; 3/4 in. thick Type IP -X3, 1 in. legs, fabricated from No. 25 MSG galv steel. Attached to floor and ■ ULTRACODE, ULTRACODE SHC or ULTRACODr WRC. ceiling with fasteners spaced 24 in. OC. LOOK FOR THE UL MARK ON PRODUCT . r• ;ECTION 08000 - DOOR SCHEDULE I Doors . Frames Size Description Desc. Details o 0. z z z z o z • s 00°u 00 >," c v u t7 c Remarks Door No. Room Name = j e .W . - 1 L a a v g x $ 1 ; u .= .0 4 ? in 3 a o m e F .E w �- ;n F _ n x O.: _ W H T S P. Mat Fin. Type E L Mat. Fin. l H T EG DP 202.00 Waiting Room * * * * - * * A - 20M 1 HM PT - - - - - 202.02 Hallway * * * * - a a A , - NR 2 * • - - - - - 202.03 Hallway • * * * - * * A - 20M 1 HM PT - - - - - 202.04 Toilet * • a * - * • A - NR 4 ' * * - - - - - . 202.05 Treatment 1 • * * • - a * A - NR 3 • * - - - - - 202.06 Treatment 2 REFER TO PLANS AC PF D - NR - - - - - - - - 202.07 Treatment 3 REFER TO PLANS AC PF D - NR - - - - - - - 202.10 Hallway REFER TO PLANS AL PF C - NR - - - - - - - - 202.11 Treatment 5 REFER TO PLANS AC PF E - NR - - - - - - - - 202.12 Treatment 6 REFER TO PLANS AC PF E - NR - - - - - - - - , 202.13A Storage 6' -2" * - - * M PF B - NR - - - - - - - 202.13B Storage 6' -2" * - - * M PF B - NR - - - - - - - - Existing to 202.99 Housekeeping * • a • - • * A E 20M - HM PT - - - - - remain 101.00 Conference a • • a - a * A - NR 5 * * - - - - - KEY: UON Unless otherwise noted 20M 20 Minute rated door AC Accordian door PF Prefinished NR None rated door HM Hollow metal M Sliding Mirror PT Paint AL Aluminum Sliding Door 1 , E -: V: FELL ',ra'r 4LUM. — FQ4MNG I' }_ - - -.1 1 I' TEMP. — / 1 C'1-55 — 1� O U I I F LUE•: It10CC I iI ;I` 5_Ip1�Li i I ! 1 r" D �' < 'I i MiR RAGS 11 ' t" CCCFC ' 1 ' I I? I 1 �.... DOOR TYPES ) 1 September 2002 Scholls Ferry MOB - Rehab / Conference Room 08000 - 1