Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
FIRE SYS M ACCESSORY . .t3 kv Firepower 5499 ) Distributed Power Module at/9.3 3'�� 1 •-, a 603-00 „5-.8? , ,. ._ _ _i_ . 1 Liq-). Supervision Auxiliary Ambient Firepower 5499 supervises a variety of power circuit: 1 Temp.: 32° to 120° F functions including: Notification 0° to 49° C • Low AC power. circuits: 4 Humidity 85% non- condencing • Low battery condition. Output max. • Earth ground fault configuration: 2 Class A (Style Z) Mechanical • Auxiliary output power limit 4 Class B (Style Y) Dimensions: 12.25° W x 16° H x condition. (1 Class A & 3° D (30.88 cm W • EOL supervision trouble or power 2 Class B) x 40.64 cm H x limited condition at an output. Amps per 7.62 D cm) When a trouble condition occurs, output circuit: 3.0 (9.0 amps total) Indicator Lights Firepower 5499 creates a trouble Notification . AC power on : Green condition on the host control signal circuit output: 20.4 to 27.3 VDC Battery trouble: Yellow circuits to which it is connected. @ 3.0 amps each, Firepower 5499 still maintains the 4.7 in EOL Ground fault: Yellow ability to be activated by the host resistor required Aux Trouble: Yellow control. In addition, the 5499 provides a on each Class B Out Form C trouble relay output as an circuit troubles (1-4): Yellow alternative to using the notification circuit trouble. No. of inputs 2 Approvals: Electrical Specification Input UL: 864 & 1481 configuration: 2 Class B (Style Y) or NFPA: 72 AC Input: 120 VAC at 3.6A 2 Class A (Style Z) Output: 24 VDC at 9 A Input Current: voltage range: 9 - 32 VDC Standby 75 mA Battery charging Alarm 175 mA capacity: 33.0 AH Model 5499 Block Diagram Signal Circuit Output S Input l 1 Signal 1 Distributed Signal 2 Signal Circuit Output Signal 2 Power input Module 5199 Signal3 (Optional) Signal 4 120 VAC ' Aux. Power Trouble Output Local Flre Control (Alternative to notification circuit trouble.) IZ3SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800 - 446 - 6444 or in Minnesota 763- 493-6435 FORM# 350396, Rev. 08/01 FAX: 763-493 -6475 Copyright ®2001 Silent Knight World Wide Web: http: //www.silentknight.com 400 SeriesTM *Th_ SYSTEM Direct -Wire Ionization SENSOR` il Smoke Detector Models Available 1400, 2-Wire 1400 2-Wire Ionization Smoke Detector 1412B, 4 -Wire 1424, 4 -Wire 11:1't tit Accessories �i ,�l f ��.; A77 -7166 End of line relay module, J .'`-g 1 12/24 VDC k RA400Z Remote LED annunciator MOD400R Sensitivity test module CRT400 Ionization cover removal tool ' ' RS14 Replacement screen Product Overview 12 or 24 volt operation All 400 Series ionization smoke detectors include a unique dual source, dual unipolar Removable cover and insect screen for chamber detection design which will sense the presence of smoke particles produced by easy cleaning fast combustion as well as slow smoldering fires. This chamber exhibits increased stabili- ty, significantly reduces nuisance alarms, and provides better performance at higher air Visible LED blinks In standby, latches on velocities. in alarm Twist on mounting bracket with The 400 Series meets the performance criteria required by UUULC. Additional key fea- tamper option tures include an LED which blinks in standby and latches on to indicate an alarm. Detectors feature convenient field testing and sensitivity metering. The model 1400 Dual unipolar chamber design includes remote LED annunciator capabilities using the RA400Z. Field sensitivity metering of detector to meet NFPA 72 requirements Engineering Specifications SEMS screws for easy wiring Smoke detector shall be an ionization type (model 1400, 1412B, or 1424) as manufac- tured by System Sensor. Wiring connections shall be made by means of SEMS screws. 3 warranty Detector will have a visible LED which will blink in standby and latch on in alarm. The Sealed against dirt, insects, and detector shall have a sensitivity of 1.9 x 0.6 % /ft. as measured in the UL smoke box. The back pressure detector screen and cover should be easily removable for cleaning. It shall be possible to perform a sensitivity and functional test on the detector without the need of generating smoke. The detector shall have a mounting bracket that allows for mounting to a 3 '/2" or 4" octagon box or 4" square electrical box. (2!) (p MEA 1 APPROVED approved • SECTION NP7 -12 Independence Sealed Rechargeable Lead -Acid Battery NP7=11 _ _ NP7 1 1 � Specifications • Nominal Voltage 12V Nominal. Capacity 20 hr. rate of 0.35A to 10.50 V.... 7.0Ah T•~ 10 hr. rate of 0.65A to 10.50 V.... 6.5Ah ©CVO✓ 5 hr. rate of 1.19A to 10.20 V... 5.95Ah 1 hr. rate of 4.20A to 9.60 V .... 4.2Ah Diit9 ertS10 is Weight (approx.) 6 17 lbs go (2.64 kgs) o ... , Energy density (20 hr. rate) 1 4 9 WH /cubic inch (91.0 WH/litre) 2sa t 004) ® Specific en ergy (20 hr. rate) _ - - - 1 3 .6 WH/pound F ni t (30.0 WH /kg) (5.95 ± 000 s Internal resistance of charged battery 30 milliohms (approx.) R t) Maximum discharge current with standard terminals 40 amperes *�. Maximum short - duration dis c ha e current a 21 amperes � 1 Operating temperature range Charge ._.. ... 5 °F to ( -15 °C to Discharge -4 °F t a e 140°F DIMENSIONS: MM (INCHES) :.:: ( - 20°C to 60°C) Charge retention (shelf life) at 68° harge rater ' n sh ife a 68°F (20°C) 1 month 97% 3 months 91% 6 months t S'Pllni NMI Available with .250 option Life expectancy ... Standby use 3 to 5 years .iss t nod INCH = MM Cycle use (approx.) 100% depth of discharge 250 cydes .50 mn .250 6.35 : :: 50% depth of discharge 550 cycles .185 4.70, 30% depth of discharge 1200 cyder 3 124 3.15 Sealed construction I � � - ;, - .098 2.49 Can be operated or stored in any position .060 1.52 without leakage. .031 0.79 - ::::::-.: Standard terminal . . Quick Disconnect .187 020 0.51 r or Optional 250 .004 0.10 Housing material ABS Resin or ABS Flame Retardant (UL94 -V0) nm ± tos DIMENSIONS: (INCHES) , 7 31k1 RECOGNIZED BY UL, File No. MH 16464 YUASA Specifications Height Operating Humidity Range Mounting 3.12" (8.1 cm) 10% to 93% Relative 31/2" or 4" octagon box, Diameter Humidity (non- condensing) 4" square box with plaster ring, 5.5" (13.9 cm) Air Velocity Rating 50, 60, 75 mm boxes Shipping Weight 1200 fpm maximum Spacing • 0.7 lbs. Sensitivity Install per NFPA 72 and local require - 1.9 ± 0.6 % /ft. nominal ments. On smooth, flat ceilings, spac- Operating Temperature Range ing of 30 feet may be used as a guide. 32 °F to 120 °F (0 °C to 49 °C) Wiring 12 -22 AWG, twisted pair recommended Electrical Ratings 1400 1412B 1424 System Operating Voltage 12/24 VDC (8.5-35 VDC) 12 VDC (11.3 -17.3 VDC) 24 VDC (20 -29 VDC) Standby Current 120 pA max. 120 pA max. 120 pA max. Alarm Two -wire control panels 77 mA 41 mA must be current limited 100 mA or less Relay Contact Ratings 1 Form A Alarm: 2A @ 30 VAC /DC 1 Form C Auxiliary Alarm: 2A @ 30 VAC /DC; .6A @ 110 VDC; 1A @ 125 VAC Ordering informaton Part Number Description 1400 Ionization detector, 2 -wire, 12/24 VDC, for control panels 1412B Ionization detector, 4 -wire, 12 VDC, for control panels 1424 Ionization detector, 4 -wire, 24 VDC, for control panels A77 -716B End of line relay module, 12/24 VDC RA400Z Remote annunciator (LED) MOD400R Sensitivity Test module (see below) CRT400 Ionization cover removal tool RS14 Replacement screen `;!!r►'? "- The MOD400R Field Sensitivity Test Module ; can be used with any standard DC voltmeter �r or multimeter to check the sensitivity range of System Sensor's detectors (satisfies -.fin -, NFPA 72 requirement for sensitivity testing). I System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In China System Sensor In Far East System Sensor In India 3825 Ohlo Avenue Ph: 905.812.0767 Ph: 86.29.524.6253 Ph: 85.22.191.9003 Ph: 91.11.558.2119 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.524.6259 Fx: 85.22.736.6580 Fx: 91.11.527.6815 Ph: 800 SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor In Australia Fx: 630/377-6495 Ph: 44.1403.276500 Ph: 65.273.2230 Ph: 613.54.281.142 Documents on Demand Fx: 44.1403.276501 Fx: 65.273.2610 Fx: 613.54.281.172 1-800-736-7672 x3 www.systemsensor.com a 2001 System Sensor. The company reserves the right to change product specifications without notice. A05.0219002•6/O1.6780 ARCHITECTS AND ENGINEERS SPECIFICATIONS The audible /visual notification appliances shall be Wheelock Series NS /NS4 Horn Strobe appliances and Series NH Horn appliances or approved equals. The Series NS /NS4 appliances shall meet and be listed for UL Standard 1971(Emergency Devices for the Hearing- Impaired for Indoor Fire Protection Service). The Series NH Horn shall be UL Listed under Standard 464 (Fire Protective Signaling). The horn strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of two (2) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of opv (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexhiti lens. The Series NS /NS4 shall be of low current design. Where wall mount, Multi- Candela appliances are specified, the strobe intensity shall have a minimum of four (4) field select- able settings and shall be rated per UL Standard 1971 for: 15, 30, 75 or 110 candela. The selector switch for selecting the candela setting shall be tamper resistant and not accessible from the front of the appliance. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS- 12/24 -8 Power Supply with built -in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobes shall revert to a non - synchronized flash -rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series NS /NS4 Horn Strobes shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single -gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. SPECIFICATION & ORDERING INFORMATION Model Order Strobe Candela Non- Sync wl SM, DSM 24 12 2 4 Mounting Options* Code Sync or PS- 12/24 -8 VDC VDC WIRE WIRE NS- 24MCW -FR 9404 15/30/75/110 X X X - X - B,D,E,F,G,H,J,N,O,RX NS- 24MCW -FW 9405 15/30/75/110 X X X - X - B,D,E,F,G,H,J,N,O,R,X NS- 241575W -FR 7806 15 (75 on Axis) X X X - X - B,D,E,F,G,H,J,N,O,R,X NS- 121575W -FR 7816 15 (75 on Axis) X X - X X - B,D,E,F,G,H,J,N,O,R,X NS4 - 24MCW -FR 9406 15/30/75/110 X X X - - X B,D,E,F,G,H,J,N,O,R,X NS4- 24MCW -FW 9407 15/30/75/110 X X X - - X B,D,E,F,G,H,J,N,O,R,X NS4- 241575W -FR 7901 15 (75 on Axis) X X X - - X B,D,E,F,G,H,J,N,O,R,X NH- 12/24 -R 7449 24V X X X X X - B,D,E,F,G,H,J,N,O,RX *Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA Distributed By: National Sales Office 800 - 631 -2148 Canada 800 - 397 -5777 E -Mail: Info @wheelockinc.com http: / /www.wheelockinc.com Member 273 Branchport Avenue • Long Branch, NJ 07740 • TEL: 732 - 222 -6880 • FAX: 732 - 222 -2588 S2100 Rev. 01/03