Permit CITY OF TIGARD MASTER PERMIT
COMMUNITY DEVELOPMENT Permit#: MST2012 -00182
T I G A R D 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 07/26/2012
Parcel: 2S109DD07300
Jurisdiction: Tigard
Site address: 12790 SW REMBRANDT LN
Subdivision: BELLA VISTA Lot: 3
Project: Levine
Project Description: Installation of residential solar photovoltaic
BUILDING
Floor Areas Required Setbacks Required
Stones: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $0.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0
Drains: 0
Tubs /Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Drywell- Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Fum <100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Fum > =100K: 0
ELECTRICAL
• Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0 -200 amp: 0 W/ Svc or Fdr: 0
Ea add'I 500 sf: 0 201 -400 amp: 0 201 -400 amp: 0 W/O Svc/Fdr: 0
Mid Home /Feeder /Svc: 0 401 -600 amp: 0 401 -600 amp: 0
601 -1000 amp: 0 601 +amp- 1000v: 0
1000 +amp /volt: 0
ELECTRICAL - RESTRICTED ENERGY
SF Residential
Audio & Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Other: N Other Description: Ecompasing: N
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
ALT SF VB R -3 0
Owner: Contractor:
LEVINE, GAIL E & JEFFREY A WILLAMETTE CREST PROPERTIES Required Items and Reports (Conditions)
12790 SW REMBRANDT LN 14775 SE 82ND DR
TIGARD, OR 97224 CLACKAMAS, OR 97015
PHONE: 503- 598 -6789 PHONE: 503- 635 -0117
FAX: 503- 635 -0157
Total Fees: $316.38
This permit is issued subject to the regulations contained in the Tigard Municipal Code. State of OR. Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952- 001 -0010 through OAR 9 2- 001 - Y • u ay obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344.
_
Issued By: . — Permittee Signature: �ir/ ,A
Call 503.639.4175 by 7:00 a.m. for the next available inspection date.
This permit card shall be kept In a conspicuous place on the job site until completion f the project
Approved plans are required on the Job site at the time of each Inspection.
•
Building Permit Application
Residential NQISIA1fl owicrune FOR OFFICE USE ONLY
City of Tigard CO RM�1 nap Da 7/ lealle H � ,z2
CORM
74 Permit No,
• 1 3125 SW Hall Blvd., Tigard, O 97223 � Plan Review
is Phone: 503.718.2439 Fax: 503.598.1961)10Z 6 11 11 DateB : �► 'i 6� s er Permit:
1 . t G A R D Inspection Line: 503.639.4175 Date Ready/13);. lwis: HI See Page 2 for
•
Internet: www.tigard -0Ggov :] Notified/Method: Supplemental Information
TYPE OF " tt 1' REQUIRED DATA: 1- AND 2- FAMILY DWELLING
® New construction ❑ Demolition Permit fees* are based on the value of the work performed.
Indicate the value (rounded to the nearest dollar) of all
❑ Addition/alteration/replacement ❑ Other. equipment, materials, labor, overhead, and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
® 1- and 2- family dwelling ❑ Commercial/industrial
Valuation: $
❑ Accessory building ❑ Multi - family Number of bedrooms:
❑ Master builder ❑ Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: 12790 SW Rembrandt Lane New dwelling area: square feet
City/State/ZIP: Tigard / Oregon / 97224 Garage/carport area: square feet
Suite/bldgJapt. no.: Project name: Levine Covered porch area: square feet
Cross street/directions to job site: Deck area square feet
Other structure area: square feet
REQUIRED DATA: COMMERCIAL -USE CHECKLIST
Subdivision: I Lot no.: Permit fees* are based on the value of the work performed.
Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all
equipment, materials, labor, overhead, and the profit for the
DESCRIPTION OF WORK work indicated on this application.
2.55 KW PV solar array Valuation: $
Existing building area: square feet
New building area: square feet
® PROPERTY OWNER I ❑ TENANT Number of stories:
Name: Jeffrey & Gail Levine Type of construction:
Address: 12790 SW Rembrandt Lane Occupancy groups:
City / State/ZIP: tigard / OR/ 97224 Existing:
•
Phone: (503)598-6789 Fax: ( ) New:
® APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES*
Business name: Willamette Crest Properties, dba Advanced Energy (Please refer tn fee schedule�
Structural plan review fee (or deposit):
Contact name: Julia Werner
• FLS plan review fee (if applicable):
Address: 14775 SE 82 Dr
Total fees due upon application:
City/State/ZIP: Clackamas / OR / 97015
Phone: (503) 635-0117 I Fax: : (503) 635-0157
Amount received:
E -mail: julia@advancedenergyoregon.com
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
Commercial and residential prescriptive installation of
CONTRACTOR roof -top mounted PhotoVoltaic Solar Panel System.
Business name: Willamette Crest Properties Submit two (2) sets of roof plan with connection details -
and fire department access, along with the 2010 Oregon
Address: 14775 Se 82 Dr Solar Installation Specialty Code checklist.
City/ State/ZIP: Clackamas / OR / 97015 Permit Fee (includes plan review $180.00
and administrative fees):
Phone: (503) 635-0117 Fax: (503) 635-0157 State surcharge (12% of permit fee): $21.60
CCB lic.: 180882
Total fee due upon application: $201.60
Authorized signature: M . _ , This permit application expires if a permit is not obtained
/ � Ci within 180 days after it has been accepted as complete.
Print name: Mike Werner Date: 7/19/12 * Fee methodology set by Tn-County Building Industry
Service Board.
I:\ Building \PermitABUP- RESPermitApp.doc 02/24/2011 4404613T(Il/02 /COM/WEB) / / 7?
Electrical Permit ApplicalftgaVE hint ()H. I( I. I NI. ()\1.1
1 2012 Received 2
City of Tigard I l J L Date/B : 1 Q Permit No.. 5- �w L III • 13125 SW Hall Blvd., Tigard, OR 47223 Plan Review
Phone: 503.718.2439 50 � nat : Other Permit:
'I I LLA It 1) Inspection Line: 503.ti3 5
Fax: t 1IGAR Date Ready,'By: turfs: RI See Page 2 for
Internet: www.tigard- or.gov BUILDING DIVISION Notified/Method: Supplemental Information
TYPE OF WORK PLAN REVIEW
® New construction ❑ Addition/alteration /replacement Please check all that apply (submit 2 sets of plans w /items checked below):
❑ Service or feeder 400 amps or more ❑ Building over three stories.
❑ Demolition ❑ Other:
where the available fault current ❑ Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑ Floating buildings
less to pnnnd, or exceeds 14,000 ❑ Commercial -use agricultural
® I- and 2- family dwelling ❑ Commercial /industrial ❑ Accessory building amps for all otter installations. buildings.
❑ Multi - family ❑ Master builder ❑ Other: ❑ Fire pump ❑ Installation of 75 KVA or
❑ Emergency system. larger separately derived system.
JOB SITE INFORMATION AND LOCATION
❑ Addison of new motor load of ❑ "A ", "E ", "I -2 ", "1 -3 ",
Job no.: Joh site address: 12790 SW Rembrant Lane IoOHP or more occupancy
❑ Six or more residential units. ❑ Recreational vehicle parks.
City /State /ZIP: Tigard / OR / 97224 ❑ Health -care facilities. ❑ Supply voltage for more than
❑ Flaoardnus locations 600 volts nominal
Suite/bldg. /apt. no.: Project name: Levine ❑ Service or feeder 600 amps or more.
FEE SCHEDULE
Cross street/directions to job site: Description I Qt 1 t• I Thal I •
i New residential single - or multi- family dwelling unit.
Includes attached garage.
Subdivision: Lot no.: 1.000 sq ft. or less 168.54 4
Ia. add'1 500 sq. ft. or portion 33.92 I
Tax map /parcel tto,. Limited energy, residential
DESCRIPTION OF WORK (with above sq. ft.) 75 00 2
Limited energy, multi - family
75.00 2
2.55 KW PVSolar Array on roof residential (with above sq. ft.)
Services or feeders installation, alteration, and/or relocation
200 amps or less / 100.70 _2
❑ PROPERTY OWNER 1 ❑ TENANT 201 amps to 4(10 amps 133.56 2
Name: 401 amps to 600 amps 200.34 2
601 amts to 1,000 amps 301.04 2
Address: Over 1,000 amps or volts 552.26 2
City/State/ZIP: Temporary services or feeders installation, alteration, and /or
relocation
Phone: ( ) Fax: ( ) 200 amps or less 59.36 1
-- 201 amps to 400 amps 125.08 2
Owner installation: This installation is being made on property that I own which is not
401 amps to 599 am 168.54 2
intended for sale, lease, rent, or exchange. according to ORS 447, 449, 670, and 701. amps
Branch circuits— new, alteration, or extension, per panel
Owner signature: Date: A. Fcc for branch circuits with
® APPLICANT I ❑ CONTACT PERSON above service or feeder fee, 7 42 2
each branch circuit
Business name: Willamette Crest Properties 13. Fee for branch circuits without
service or feeder fee, first
Contact name: Julia branch circuit 56.18 2
— - - — Each add'I branch circuit 7.42 2
Address: 14775 SE 82 " Dr Miscellaneous (service or feeder not included)
City /Stale /'ZIP: Clackamas/ OR / 97015 Each manufactured or modular 67 84 2
dwelling, service and/or feeder
Phone: (503) 635 -0117 Fax: : (503) 635 -0157 Reconnect only 67.84 _ 2
E - mail: julia@advancedenergyoregon.com Pump or irrigation circle 67.84 2
CONTRACTOR Sign or outline lighting 67.84 2
Signal circuit(s) or limited - energy
panel, alteration, or extension. Page 2
Business name: 2
3 Z- / c-1 Each additional inspection over allowable in any of the above
Address: 0569 sf //cur 2-- /,3 Additional inspection (I hr min) 66.25/ hr
City /State /ZIP: O/, d el.-, 02 t7a Ys- Investigation (1 hr min) 78 .25 /hr
I ndustrial plant (1 hr min) 78.18 / hr
Phone: (503 )6 .57 -Al / -73 I Fax: (c5 )t.6", 7/ Inspections for which no fee is
90.00/ hr
specifically listed (14 hr min)
CCB Lie,: 2 -2 y) Electrical Lic.:3- y(po Suprv. Lie.: 3793 5 ELECTRICAL PERMIT FEES
Suprv. Elect . g �� re, re u � /0/03 Subtotal:
Plan review (25% of permit fee):
Print name: Bill J u - O n Date: 7/ State surcharge (12% of permit fee):
Authorized signature: TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
Print name: Date: • days after it has been accepted as complete.
• Numb°r of inspections allowed per permit.
I.\ Budding \Pumits\ELC- PemritApp_dne 07/01/10 440.461511 I I /OS/COM /Wt7r
AtSraze; /a o- I 8" 7,
1 7.79 o S w ,2e wd,.t(, f: G,
•
III City of Tigard
° Building Division RECEIVED
13125 SW HaII Blvd, Tigard, OR 97223 JUL 1 9 2012
Phone: 503.718.2439 Fax: 503.598.1960
T I G A R D Inspection Line: 503.639.4175 CITYOFTIGARD
www.tigard - or.gov BUILDING DIVISION
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof - Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 12790 SW Rembrant Lane
City: Tigard Zip: 97224
Owner's Name: Jeffrey Levine Date: 7/19/12 •
Contractor's Name: Willamette Crest Properties CCB #: 180882
Design Parameters of the Property /Structure
If "Yes ", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? ® N OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure ❑ Yes If "Yes ", qualifies for
"C" or less? ® No the prescriptive path.
Installations on detached Is the Ground Snow
single /two - family Load 70 psf or less?
dwelling/single /two- If "Yes ", qualifies for
family townhomes ® Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
If "Yes ", qualifies for
structures other than
❑ Yes the prescriptive path.
above
❑ No
1
1:/Building/Forms/Photo Vol taic- Checkl ist.docx
Is the construction
Type of material wood and does ® Yes If "Yes ", qualifies for
the construction qualify No the prescriptive ath.
Construction as "conventional light ❑ path.
construction?
Is the spacing 24 inches
or less?
Pre - engineered trusses. ® Yes If "Yes ", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. ® If "Yes ", qualifies for
Yes the prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If "Yes ", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance Yes If "Yes ", qualifies for
with Section 305.4(3) of ❑ No the prescriptive path.
the 2010 Oregon Solar
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle /shake checked, qualifies for
Max. two layers the prescriptive path.
® of composition
shingle.
Is the roof mounted ® Yes
Connections of solar assembly If "Yes ", qualifies for
the solar assembly connected to roof No
to the roof framing or blocking ❑ the prescriptive path.
directly?
2
(:Build ing/ Forms /Photo Voltaic - Checklist.docx
❑ Yes If "Yes ", qualifies for
Is the gauge 26 or less? ❑
No the prescriptive path.
•
115 lbs for 60 inch
spacing or less?
If "Yes ", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If "Yes ", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal anels If the width of the panel
P Width of roofing is less than 18 inches,
panels? 18 inches or less •
inches qualifies for the
prescriptive path.
Minimum #10 at 24
inches o /c?
Size and spacing of If "Yes ", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. %2" thickness, ❑ Yes
decking connected to If "Yes ", qualifies for
framing members ❑ No the prescriptive path.
w /min. 8d nails @
• 6 "/12" o /c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If "Yes ", qualifies for
solar modules module to the roof ® Yes the prescriptive path.
surface. ❑ No
3
• (:/Building/ Forms /PhotoVoltaic -Checklist.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to'buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: SolarWorld
Model Number: SW 255
Listing Agency: UL 1763
•
•
4 -
1: /Building/ Forms /PhotoVoltaic- Checklist.docx
TM SW-02-5015US 01-2012 U5
51111 module%
SW 255 mono / Version 2.0 and 2.5 Frame
PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)' PERFORMANCE AT 800 W /m', NOCT, AM 1.5
SW 255 SW 255
Maximum power P 255 Wp Maximum power P 184.1 Wp
Open dreuit voltage V 37.8 V Open circuit voltage V. 34.0 V
Maximum power point voltage Vmov 31.4 V Maximum power point voltage V mw 28.3 V
Short circuit current I 8.66 A Short circuit current I 6.99 A
Maximum power point current I , 8.15 A Maximum power point current l,,, 6.52 A
'STC:1000W /m', 25 AM 15 Minor reduction in efficiency under partial load conditions at 25'C: at 200W /m', 95%
( +/ -3 %) of the STC efficiency (1000 W /m') is achieved.
THERMAL CHARACTERISTICS COMPONENT MATERIALS
NOCT 46 °C Cells per module 60
TC I 0.004 %/K Cell type Mono crystalline
TC vw -0.30 %/K Cell dimensions 6.14 in x 6.14 in (156 mm x 156 mm)
TC P mw - 0.45%/K Front tempered glass (EN 12150)
Operating temperature - 40 °Cto85 °C Frame Clear anodized aluminum
IVVarrves for SolarWorld Sunmodule Plus SW 25S mono Weight 46.7 lbs (21.2 kg)
at 25•C cell temperature
9 SYSTEM INTEGRATION PARAMETERS
- _ - ,.
g - -, - - - -. -- -
5 7 _ -- - 1003wfm' Maximum system voltage SC II 1000 V
I 6 _ _ _ _oww ' Max. system voltage USA NEC 600 V
S -600 Ws' Maximum reverse current 16 A
I a cow/rd Number of bypass diodes 3
3 -MO wAd UL Maximum Test Load" 45 psf (2.1 kN /m
2 ' - -103 WA
1 ,---- ______ _ _ _ IEC Maximum Snow Test Load" 113 psf (5.4kN /m
O . "Please apply the appropriate factors of safety according to the test standard and local
o 10 20 so ao building code requirements when designing a PV system.
crtoduk Wimp m
ADDITIONAL DATA
Power tolerance' - Wp ... +5 Wp
1 x4 3144 (951) -- - - . . . -
SolarWorld Plus - Sorting' P, 2 P
' 1 -Box IP65
11.33 (288) Connector ' MC4
Module efficiency 15.21 %
- Fire rating (UL 790) Class C
41.30 (1050)
0.6 (153) 0.6 (153)
Version
2.5 frame
65.94 (1675) - bottom , in
mounting
holes n q
.111111 05(1265 134 (34)
• - 0.6 (153) • ■�•■• VERSION 2.0 FRAME VERSION 25 FRAME
• ■■■111 1 x4 • Compatible with `Top -Down' • Compatible with both Top-Down"
4.20 (107)' mounting methods and °Bottom° mounting methods
L • � Grounding Locations: • ♦GroundingLocations:
122 (31) 39 .41(1001) I •
4 corners of the frame -4 corners of the frame
-4 locations along the length of the
module in the extended flanges
1) Sunmodules dedicated for the United States and Canada are , - ted to UL 1703 Standard - - ■ listed by a third party laboratory. The laboratory may vary by product and region. Check with
your SolarWorld representative to confirm which laboratory h .. a listing for the prod -
2) Measuring tolerance is used conjunctions with the5olarWorl• ..••' ed i . %SolarWorld AG reserves the right to make specification changes without notice.
3) The output identified by SolarWorld (P is always higher than the nominal output (P of the module. PFlash is the power rating flashed at a SolarWorld manufacturing facility.
4) All units provided are imperial. SI units provided in parentheses.
M215 M ICROI NVERTER TECHNICAL DATA
Input Data (DC) M215- 60- 2LL- S22/S23 and M215- 60- 2LL- S22- NA /S23 -NA (Ontario)
Recommended input power (STC) 190 - 260W
Maximum input DC voltage 45V
Peak power tracking voltage 22V - 36V
Operating range 16V - 36V
Min. /Max. start voltage 22V/45V
Max. DC short circuit current 15A
Max. input current 10.5A
Output Data (AC) @208 Vac @240 Vac
Maximum output power 215W 215W
Nominal output current 1.0A (arms at nominal duration) 0.9A (arms at nominal duration)
Nominal voltage /range 208V/183 -229V 240V/211 -264V
Extended voltage /range 208V/179 -232V 240V/206 -269V
Nominal frequency /range 60.0 /59.3 -60.5 Hz 60.0/59.3 -60.5 Hz
Extended frequency range 60.0 /59.2 -60.6 Hz 60.0/59.2 -60.6 Hz
Power Factor >0.95 >0.95
Maximum units per 20A branch circuit 25 (three phase) 17 (single phase)
Maximum output fault current 1.05 Arms, over 3 cycles; 25.2 Apeak, 1.74ms duration
Efficiency
CEC weighted efficiency 96.0%
Peak inverter efficiency 96.3%
Static MPPT efficiency (weighted, reference EN50530) 99.6%
Dynamic MPPT efficiency (fast irradiation changes, reference EN50530) 99.3%
Night time power consumption 46mW
Mechanical Data
Ambient temperature range -40 °C to + 65 °C
Operating temperature range (internal) -40 °C to + 85 °C
Dimensions (WxHxD) 17.3 cm x 16.4 cm x 2.5 cm (6.8" x 6.45" x 1.0 ")*
Weight 1.6 kg (3.5 Ibs)
Cooling Natural convection - No fans
Enclosure environmental rating Outdoor - NEMA 6 * without mounting bracket
Features
Compatibility Pairs with most 60 -cell PV modules
Communication Power line
Warranty 25 -year limited warranty
Monitoring Free lifetime monitoring via Enlighten software
Compliance UL1741/IEEE1547, FCC Part 15 Class B
CAN /CSA -C22.2 NO. 0-M91, 0.4 -04, and 107.1 -01
Enphase Energy, Inc.
201 1 st Street
Petaluma, CA 94952
Phone: 877 - 797 -4743
Fax: 707 - 763 -0784
info@enphaseenergy.com
http: / /www.enphase.com 142 -00010 Rev 03