Permit a CITY OF TIGARD MASTER PERMIT
I I °.: COMMUNITY DEVELOPMENT Permit #: MST2012 -00190
TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 07/26/2012
Parcel: 2S1100608300
Jurisdiction: Tigard
Site address: 12454 SW AUTUMNVIEW ST
Subdivision: MOUNTAIN VIEW ESTATES Lot: 8
Project: Wittman
Project Description: Installation of solar photovoltaic system.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $0.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0
Drains: 0
Tubs /Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Drywell- Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Fum <100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Fum > =100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0 -200 amp: 0 0 -200 amp: 0 W/ Svc or Fdr: 0
Ea add'I 500 sf: 0 201 -400 amp: 0 201 -400 amp: 0 W/O Svc/Fdr: 0
Mfd Home /Feeder /Svc: 0 401 -600 amp: 0 401 -600 amp: 0
601 -1000 amp: 0 601 +amp- 1000v: 0
1000 +amp /volt: 0
ELECTRICAL - RESTRICTED ENERGY
SF Residential
Audio & Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Other: N Other Description: Ecompasing: N
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
ALT SF VB R -3 0
Owner: Contractor:
WITTMAN, BRIT WILLAMETTE CREST PROPERTIES Required Items and Reports (Conditions)
SORKOWITZ, ENID 14775 SE 82ND DR
12454 SW AUTUMN VIEW ST CLACKAMAS. OR 97015
PORTLAND, OR 97224
PHONE: 503 -598 -9760 PHONE: 503- 635 -0117
FAX: 503 -635 -0157
Total Fees: $316.88
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952- 001 -0010 through R 952- 0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344.
Issued By: Permittee Signature: . _ /
Call 503.639.4175 by 7:00 a.m. for the next available Inspection did/
This permit card shall be kept in a conspicuous place on the job site until coracle', • of the project
Approved plans are required on the Job site at the time of each inspection.
Building Permit Application
Residential RECEIVED I:01( OFFICE usiO \I
City of Tigard �d�L�. R D ecz atel ved : ? MEW' Permit No. ypea.- co go
11 III
• 13125 SW Hall Blvd., Tigard, OR 912 3 4 ..� i Plan Re vie
Phone: 503.718.2439 Fax: 503.590 '- • Date/13 : J�� Other Permit:
I v n R D Inspection Line: 503.639.4175 Date Ready : y: kris: ® See Page 2 for
Internet: www.tigard- or.gov CITY OFTIGARD Notified/Method: Supplemental Information
BUILDING DIVISION
TYPE OF WORK REQUIRED DATA: 1- AND 2- FAMILY DWELLING
® New construction ❑ Demolition Permit fees* are based on the value of the work performed.
Indicate the value (rounded to the nearest dollar) of all
❑ Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
® 1 - and 2- family dwelling El m
Comercial/industrial Valuation: $
El Accessory building ❑ Multi - family Number of bedrooms:
❑ Master builder ❑ Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: (2 54/Autumnview St. New dwelling area: square feet
City/State/ZIP: Tigard / Oregon / 97224 Garage/carport area: square feet
Suite/bldgJapt. no.: Project name: Wittman Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA: COMMERCIAL -USE CHECKLIST
Subdivision: I Lot no.: Permit fees* are based on the value of the work performed.
Indicate the value (rounded to the nearest dollar) of all
Tax map /parcel no.:
equipment, materials, labor, overhead, and the profit for the
DESCRIPTION OF WORK work indicated on this application.
6.12 KW PV solar array Valuation: $
Existing building area: square feet
New building area: square feet
® PROPERTY OWNER ❑ TENANT Number of stories:
Name: Brit Wittman Type of construction:
Address: 12454 SW Autumnview St. Occupancy groups:
City/State/ZIP: Tigard / OR/ 97224 Existing:
Phone: (503)598 -9760 Fax: ( ) New:
® APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES*
(Please refer lo fee schedule)
Business name: Willamette Crest Properties, dba Advanced Energy
Structural plan review fee (or deposit):
Contact name: Julia Werner
FLS plan review fee (if applicable):
Address: 14775 SE 82 Dr
City/State/ZIP: Clackamas / OR / 97015 Total fees due upon application:
Amount received:
Phone: (503) 635-0117 Fax: : (503) 635-0157 -
E -mail: julia@advancedenergyoregon.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
CONTRACTOR Commercial and residential prescriptive installation of
roof -top mounted PhotoVoltaic Solar Panel System.
Business name: Willamette Crest Properties Submit two (2) sets of roof plan with connection details
and fire department access, along with the 2010 Oregon
Address: 14775 Se 82 Dr Solar Installation Specialty Code checklist.
City/State/ZIP: Clackamas / OR / 97015 Permit Fee (includes plan review $180.00
and administrative fees):
Phone: (503) 635-0117 [ Fax: (503) 635-0157 State surcharge (12% of permit fee): $21.60
CCB lic.: 180882
Total fee due upon application: $201.60
• Authorized signature: �) fi' /- This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
methodology
Print name: Mike Werner Date: 7/19/12 * Fee
Service Board. set by Tri County Building 4dustry
I:\Building \Permits \BUP- RESPermitApp.doc 02/24/2011 440 - 4613T(II /02 /COM/WEB) //5
. 2..
07/18/2012 21:24 3608827450 MJ ELECTRICAL PAGE 02/02
Jul 18 12 08:19p P
•
•
Electrical Permit Application EIVED ' c 11, c. : i• r 1; i i : r 1 - 1 v 1
City of Tigard 7REY Ferries 'no.: gT It 40 •
13125 SW Elan Blvd_ Tigard. OR 9722) U L 2 4 7 3 12 Pion ttamioat
' Phone: 503.718 Pax: 503.598.1960 Dads - athcr Rosa .
i h ;.., r.: fnspeoti0n Unc: 503.6394175 CITY OF T1GARD i�a Ra�t/ity „Iris Eir Pane 2 to
Internet: wwwb . M.0r,2ov DIVISION ® y /VISION vl0tifiedrMrJtpd
— Supplemental informatiea .
TYPE OF WORK t C V PLAN REVIEW
® New construction ❑ Addition /alteration/replacement nano dock an that apply (sub j ICta orplaDs warns cracked bola): or more 0 Rudd* ow- dam stoner. .
ID Service Demolition ❑ Other: m e n.eitsble A-' c CI Moines bom
CATEGORY OF CONSTRUCTION coots mow ow mope 415'0 volts or O Ming boildenes.
Inn to mod, or meceds 14.000 0 Canweroialuse agriculture!
. IN 1- and 2-family dwelling ❑ Comm c d/industrial ❑ Accessory building amp for all otlta inrlafnaiotts. buildings.
o Multi - family 0 Master builder ❑ Otha: ❑ F6c p rep. O 109111111111011 oils KVA or
0 JOB SITE INFORMATION AND LOCATION ['Addition y new motor -r. derived system.
D Addtitar of new motor timid of 1:1 "2". `14', " 1 3",
Job no.: 1 Job sire address: 1246'4 SW Autiomoview St - - 10011? ormore - moaner
Sic or more residential units. 0 Rwolforml vesicle ma.
City/State/ZIP: T t rd / OR 1 972.24 0 Health-cam tontines, 0 Supply voltage for more flues
• ❑1{ 'iRWdAaa iooWions.
tY • 600 wet nominal
Suite/bldg. /apt. no.: , Project name: W ittni a 0 Service or Andre 600 awe or more. _ ;
FEE SCHEDULE
C:rtt<4s street/dinxtions (0 job site: oauriotioe T IQo i tsar. I Teat - I • -
New residential singe- or mid- family dwdneg unit. •
lodudes atbadked game.
Subdivision: I Lot no.: 1,000 sq. A. or tees 16834 4 •
Fa. ►Ad'I 300 m. R or portion 33.92 I
Tax map/parcel no.: Limited enemy, residential
75 2
>DESCRIPTIO4 OF WORK S w lltahoveaq IL) _
Limited cone, maIG•fbmily 75.00 2
6.12 KW Molar Array oa roof residential (with above sq. I )
Sesuttee or $edem installation and/or relocation
No amps or lam ( 100.70 2
• ❑ PROPERTY OWNER ip Mawr 201 amps w 400 imps 133.56 2
401 ,s to 600 amps 200.34 I . 2
Name: 601s to ► 000 amps 301.04 2
Address: Over LOCO armour volts 552.26 2
a @wry services or feeders installation, afaeratioe, and/or
My/Stale/ZIP: location
Phone: ( ) I Fax: ( ) 200 maps or less , 59.36 I
201 mops to 400 amps 125.08 2
Owner installation: This installation is being made on property that 1 own which is not -
aol antra w s99 amps 168.54 2
intended for auk, lease rent., or exchange, according to ORS 447, 449, 670, and 701. Branch eitt tetr.alteratloon, or elticnsion, panel - •
Owner si patine: "". Date: A. Fee for brands circuits wii
® APPLICANT I . c3 CONTACT PERSON above stn t a or Rieder fee 7.42 2
each branch sires* 1
Business name: Wigam can Crest Properties 6. Foe for branch circuits without
._ - service or fbeder fee. first 56.18 i 2
Contact non= Julia breach circuit 1
- -- Each addi branch circuit 7.421 2
Addrett: 14775 SE 112"13r Miaedfaneorm or&eder roe iarloded)
Filch maatrfa 67.84_ mad or modular I 2
Caterer /StateJZI P: Clackamas/ OR / 97015 d wdlin s, I wruiec mwtror ewer
Phone: (503) 635.0117 I Fax: (503) 635 -0157 Rccom ect o 67.84 2
pump or Irrlgmton orate 67.84 2
1t-mail: julie@a [lvaneedereergraregOn.totn S- or outl Ggtiting 67.84 2
CONTRACTOR signet chicult(s) orlimdted
Business name: MW Electrical Jac panel. alteration. or extension. _ Ptas 2 _ 2
Eae6 additional inspection over aaawablr in any afar above
Addr as; PO Boa 1673 Additional inspection (i In min) 66-25/1:4 .
Cdy/S late/ZIP: Brush Prairie / WA / 98606 ind a p a t to rain) 78.18 r
Iadnta 78.18/ht
Phwe (360) 839 -3316 I Fax: (360) 8$1-7450 Inspections for which no fee is 4D hr
spu ifmcally hoed mm)
CCB Lie.: 182623 I Electrical Lie.: C423 Suprv. Lie.: 5375$ ELECTRICAL MOOT FEES
•Subtotal:
Suprv. Electrician silgtawrc, requited: - plan •
review (25 %ofperenit fix):
Q Sono curets :ow (t.34. of permit racy:
Print nBdt M t t��t,'e { Li . `' P TOTAL PERMIT FEE
Authorized signaillre: 71d permit apptiearioo wires if a permit Is Dot obtained within ISO
daye Oka it lass been accepted as complete
Print name: Date: meter of inspections allowed pot perodt.
-:t6'+ aikeresieatGC- PensitAsmAoc a70tnO u0.761541 :AatCOM t to
/2'/5 / . �u�vkt�„� g /1-ISTRoa -029 9
City of Tigard
RECEIVED
JUL 2.4 73;Z
Building Division
13125 SW Hall Blvd, Tigard, OR 97223 CITYOFTIGARD
Phone: 503.718.2439 Fax: 503.598.1960
BUILDING DIVISION
TI G A R D Inspection Line: 503.639.4175
www.tigard- or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof - Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 12454 SW Autumnview St.
City: Tigard Zip: 97224
Owner's Name: Brit Wittman Date: 7/19/12
Contractor's Name: Willamette Crest Properties CCB #: 180882
Design Parameters of the Property /Structure
If "Yes ", does not
Flood Hazard Is the installatio ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? ® N OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure ❑ Yes If "Yes ", qualifies for
"C" or less? ® No the prescriptive path.
Installations on detached Is the Ground Snow
single /two - family Load 70 psf or less?
dwelling/single /two- If "Yes ", qualifies for
family townhomes ® Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
If "Yes ", qualifies for
structures other than ❑ Yes the prescriptive path.
above
❑ No
1
I:Bu i ld ing/ Forms /PhotoVoltaic- Checkl ist.docx
Is the construction
Type of material wood and does ® Yes If "Yes ", qualifies for
the construction qualify No the prescriptive ath.
Construction as No light ❑ path.
construction?
Is the spacing 24 inches
or less? •
Pre - engineered trusses. ® Yes If "Yes ", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. ® If "Yes ", qualifies for
Yes the prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If "Yes ", qualifies for
racking less than or ❑ No • the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance Yes If "Yes ", qualifies for
with Section 305.4(3) of ❑ No the prescriptive path.
the 2010 Oregon Solar
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle /shake checked, qualifies for
Max. two layers the prescriptive path.
® of composition
shingle.
Is the roof mounted
Connections of solar assembly Yes
the solar assembly connected to roof No If "Yes", qualifies for
to the roof framing or blocking ❑ the prescriptive path.
directly?
2
I:B u i Id i ng/Fomms/Photo Voltai c -Checkl ist. docx
❑ Yes If "Yes ", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
• spacing or less?
If "Yes ", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If "Yes ", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of S
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inche Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal anels If the width of the panel
P Width of roofing is less than 18 inches,
panels? 18 inches or less
inches qualifies for the
prescriptive path.
Minimum #10 at 24
inches o /c?
Size and spacing of If "Yes ", qualifies for
•
fastener? El Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. V2" thickness, El Yes
decking connected to If "Yes ", qualifies for
framing members ❑ No the prescriptive path.
w /min. 8d nails @
6 "/12" o /c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If "Yes ", qualifies for
solar modules module to the roof ® Yes the prescriptive path.
surface. ❑ No
3
1:Bui ld ing/ Forms /PhotoVoltaic- Checkl ist.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
•
PV Modules
Manufacturer: SolarWorld
Model Number: SW 255
Listing Agency: UL /703
3
•
•
4
I: Building /Foims/Photo Voltaic -Check) ist.docx
, ,
. .
Sunmodule/ SW- 02- 5015US 01 -2012 US
SW 255 mono / Version 2.0 and 2.5 Frame
PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)' PERFORMANCE AT 800 W /m', NOCT, AM 1.5
SW 255 _ SW 255
Maximum power P 255 Wp Maximum power - P_ 184.1 Wp
Open circuit voltage V 37.8 V Open circuit voltage V. 34.0 V
Maximum power point voltage V, 31.4 V Maximum power point voltage V m1,P 28.3 V
Short circuit current I 8.66 A Short circuit current I 6.99 A
Maximum power point current I mp 8.15 A ' Maximum power point current I 6.52 A
•STC:1000W /m', 25 AM 15 Minor reduction in efficiency under partial load conditions at 25'C: at 200W /m', 95%
( +/ -3 %) of the 5TC efficiency (1000 W /m') is achieved.
THERMAL CHARACTERISTICS COMPONENT MATERIALS
NOCT 46 °C Cells per module 60
TC I 0.004 %/K Cell type Mono crystalline
TC va - -030 %/K Cell dimensions 6.14 in x 6.14 in (156 mm x 156 mm)
TC P , , - 0.45 %/K Front tempered glass (EN 12150)
Operating temperature - 40 °Cto85 °C Frame Clear anodized aluminum
IWcurves for SolarWorld Ssmmodule Plus SW 255 mono Weight 46.7 lbs (21.2 kg)
at 25'C cell temperature
to .--- - - - - -- – -- -- — SYSTEM INTEGRATION PARAMETERS
3 7 • ' - . ----- _ --Imo Wm' Maximum system voltage SC II 1000 V
1 6 1 — -- -_— - _ — eoow ' Max. system voltage USA NEC 600 V
S r -- - -600 why' Maximum reverse current 16 A
I 4 ®ov+Jn+" Number of bypass diodes 3
-
3
_ 700 Wir' UL Maximum Test Load" 45 psf (2.1 kN /m=)
I
IEC Maximum Snow Test Load" 113 psf (5.4kN /m')
i
O _ **Please apply the appropriate factors of safety according to the test standard and local
0 10 20 30 ao building code requirements when designing a PV system.
module Wage M
ADDITIONAL DATA
-6x 3744(951)
Power tolerance' -0 Wp... +5 Wp
SolarWorld Plus Sortingn P5ash t P m°X
1 -Box IP65
11.33 (288 Connector MC4
Module efficiency 15.21 %
Fire rating (UL 790) Class C
41.30 (1050) Ob (153) Ob (153)
Version
2.5 frame
65.94 (1675) - bottom ,
mounting '^
holes n n
,,Al . 25 • 134(34) j
■Al• ••• 1 VERSION 2.0 F VERSION 25 FRAME
• ■.■�. . x4 • Compatible with 'Top Down' Compatible with both °Top Down°
4.20 (107), mounting methods and "Bottom" mounting methods
• Ilk Grounding Locations: • ♦ Grounding Locations:
•
1.22 (31) I 39.41(1001) I _ 4 corners of the frame - 4 comers of the frame
- 4 locations along the length of the
module in the extended flanget
1) Sunmodules dedicated for the United States and Canada . - tested to UL 1703 Stand and listed by a third party laboratory. The laboratory may vary by product and region. Check with
your SolarWorld representative to confirm which laborator has a listing for the pr ct. /
, 2) Measuring tolerance is used conjunctions with the Solar ■ . . Limite nty. SolarWorld AG reserves the right to make specification changes without notice.
3) The output identified by SolarWorld (P is always higher than the nominal output (P of the module. PFlash is the power rating flashed at a SolarWorld manufacturing facility.
4) All units provided are imperial. SI units provided in parentheses.
M215 MICROINVERTER TECHNICAL DATA
Input Data (DC) M215- 60- 2LL- S22/S23 and M215- 60- 2LL- S22- NA /S23 -NA (Ontario)
Recommended input power (STC) 190 - 260W
Maximum input DC voltage 45V •
Peak power tracking voltage 22V - 36V
Operating range 16V - 36V
Min. /Max. start voltage 22V/45V
Max. DC short circuit current 15A
Max. input current 10.5A
Output Data (AC) @208 Vac @240 Vac
Maximum output power 215W 215W
Nominal output current 1.0A (arms at nominal duration) 0.9A (arms at nominal duration)
Nominal voltage /range 208V/183 -229V 240V/211 -264V
Extended voltage /range 208V/179 -232V 240V/206 -269V
Nominal frequency /range 60.0 /59.3 -60.5 Hz 60.0/59.3 -60.5 Hz
Extended frequency range 60.0 /59.2 -60.6 Hz 60.0/59.2 -60.6 Hz
Power Factor >0.95 >0.95
Maximum units per 20A branch circuit 25 (three phase) • , 17 (single phase)
Maximum output fault current 1.05 Arms, over 3 cycles; 25.2 Apeak, 1.74ms duration
Efficiency
CEC weighted efficiency 96.0%
Peak inverter efficiency 96.3%
Static MPPT efficiency (weighted, reference EN50530) 99.6%
Dynamic MPPT efficiency (fast irradiation changes, reference EN50530) 99.3%
Night time power consumption 46mW
•
Mechanical Data
Ambient temperature range -40 °C to + 65 °C
Operating temperature range (internal) -40 °C to + 85 ° C
Dimensions (WxHxD) 17.3 cm x 16.4 cm x 2.5 cm (6.8" x 6.45" x 1.0 ")*
Weight 1.6 kg (3.5 lbs)
Cooling Natural convection - No fans
Enclosure environmental rating Outdoor - NEMA 6 * without mounting bracket
Features
Compatibility Pairs with most 60 -cell PV modules
Communication Power line
Warranty 25 -year limited warranty
Monitoring Free lifetime monitoring via Enlighten software
Compliance UL1741/IEEE1547, FCC Part 15 Class B
CAN /CSA -C22.2 NO. 0-M91, 0.4 -04, and 107.1 -01
•
Enphase Energy, Inc.
201 1st Street
Petaluma, CA 94952
Phone: 877 - 797 -4743
Fax: 707 -763 -0784
info @enphaseenergy.com
http: / /www.enphase.com 142 -00010 Rev 03