Plans Nov 01 05 03:53p WYATT FIRE 5036849657 p. 3
11/01/2005 15:52 5036243681 TIGARD BUILDING DEPT PAGE 01/02
City of Tigard: Fire Protection Permit . ,Checklist
. Page 2 - Supplemental Information Do °
Bes to be do Q _ � `. ": `,. :; _:,• • .
)<_) ❑ New 2.) Modification to sprinkler beads only:
❑ Addition ❑ 1 -10 heads: No plan review required.
IT Alteration 14-.11+ heads: Plan review required.
❑ Repair
Number of sprinkler heads:
Additional description of work:
TeOCT lmm rovemat
e` f'S iom: f 1 , 1 ems:$ C;:+pr =: : ` >
A?: .. ..T,F - 177 4 5111TMENVIMM
r Wet • D
Additional Stand . i • es
-
_ 0 Information: Hazard Group O.' Di
r Densi • S
( d �f ► Desi :' Area 1 SC) G)
.� K. Factor : CD C> •
Sprinkler Project Valuation: $ f ' 1
Mgr. :.Ho ' 1'F ' iii n l res
Hood Project Valuation: S
Submittal shall Batt Calculations 1• Yes
include: Individual Component ❑ Yes
Cut Sheets
Fire Alarm Project Valuation: $
]D: `''tesrden . '.'S 1 nnk"l'e a'fir alone S it
S uare Foota .e: Permit Pee: t -
0 to 2 000 $187.50 41 ` : � .
III 2 001 to 3 600 $232.50 = `? _: z
3,601 to 7,200 $292.50 •''' ���"�i •�
7,201 and eater 5381.50 ' �77♦.y� _ A_ ` , ' J � •
Sprinkler Project Square Foote e: s . ft.
Project Valuation Subtotal (A, B & C): $ Z,41S —
Permit fee based on valuation (see attached chart): S "17 . k t)
Permit fee based on • uare foota .e $ (see fees above): S l
State Surcharge 8% of Permit Fee: $ 5 1-1 —
FLS Plan Review 40% of Permit Fee: $
TOTAL: , $ Ib►D 1 1
Plan review requires a completed application and 3 sets of plans at submittal. Plan review
fees arc required at submittal.
"New" fire protection systems require that plans bear the original seal of an Oregon
licensed fire suppression engineer, or NICET level "3" technicians.
ifBuildtng\Forma?5Checklut.doc 12/29/03 •
0 C( . - 50'93
s y y s-�
l
4.
• tqci I Fire & B
.
Product o o� CE1 AL
_R
0 1 1 G PRp Custom ice /Sales:
Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791-01,0 �g1U Tel: (215) 362 -0700 / (800) 523-6512
v„ °11a - °, v Fax: (215) 362 -5385
Series 71F-B — 2.8, 5.6, and 8.0 K- factor
Upright, Pendent, and Recessed Pendent Sprinklers
Standard Response, Standard Coverage
not representative of all possible cor-
G eneral rosive atmospheres. Consequently, it w..
Is recommended that the end user be
Description consulted with respect to the suitability a a ,
4
of these coatings for any given corro- a r -
The Series TY-B, 2.8, 5.6, and 8.0 sive environment. The effects of ambi-
K- factor, Upright and Pendent Sprin- ent temperature, concentration of IFIlt
klers described in this data sheet are chemicals, and gas /chemical velocity,
standard response - standard cover- should be considered, as a minimum,
age, decorative 5 mm glass bulb type along with the corrosive nature of the '
spray sprinklers designed for use in chemical to which the sprinklers will be +
light, ordinary, or extra hazard, corn- exposed. _ 4-i., �
mercial occupancies such as banks, "
hotels, shopping malls, factories, ran- An intermediate level version of the
eries, chemical plants, etc. Series TY B Pendent Sprinkler can be
obtained by utilizing the Series TY B
The recessed version of the Series Pendent Sprinkler in combination with ...4 01111•11fti k „ .
TY B Pendent Sprinkler, where appli the Model S2 Shield. ---- -
` cable, is intended for use in areas with •-_
a finished ceiling. It uses a two -piece WARNINGS
Style 10 (1/2 inch NPT) or Style 40 (3/4 The Series TY -B Sprinklers described �v.`'1`.
_ inch NPT) Recessed Escutcheon. The herein must be installed and main- I
Recessed Escutcheon provides 1/2 tained in compliance with this docu- '
inch (12,7 mm) of recessed adjust- ment, as well as with the applicable �' /
ment or up to 3/4 inch (19,1 mm) of standards of the National Fire Protec- k
total adjustment from the flush pen- tion Association, in addition to the
dent position. The adjustment provided standards of any other authorities hay- ,•
by the Recessed Escutcheon reduces ing jurisdiction. Failure to do so may ''�...,
the accuracy to which the fixed pipe impair the performance of these de- ,, •+r',.„„T .0
drops to the sprinklers must be cut. vices.
Corrosion resistant coatings, where The owner is responsible for maintain-
applicable, are utilized to extend the ing their fire protection system and de-
life of copper alloy sprinklers beyond vices in proper operating condition.
that which would otherwise be ob- The installing contractor or sprinkler
tained when exposed to corrosive at- manufacturer should be contacted
mospheres. Although corrosion resis- with any questions.
tant coated sprinklers have passed the
standard corrosion tests of the appli-
cable approval agencies, the testing is
Model /Sprinkler
Always re Technical Data Identification o
Sheet TFP700 for the "INSTALLER Numbers
WARNING' that provides cautions B
with respect to handling and instal- TY1151 - Upright 2.8K,1/2 "NPT m
lation of sprinkler systems and corn- TY1251 - Pendent 2.8K, 1/2"NPT
ponents. Improper handling and in- TY3151 - Upright 5.6K,1/2 "NPT ,
stallation can permanently damage TY3251 - Pendent 5.6K, 1/2"NPT m
a sprinkler system or its compo- TY4151 - Upright 8.0K, 3/4 "NPT °C
nents and cause the sprinkler to fail TY4251 - Pendent 8.0K, 3/4 "NPT o
to operate in a fire situation or cause a
it to operate prematurely. TY4851 - Upright 8.0K, NPT =
8
TY4951 - Pendent .0K,1/2 "NPT
Page 1 of 8 JULY, 2004 TFPI 51
I
Page 2 of 8 TFP151
ESCUTCHEON 7/16° (11,1 mm)
PLATE SEATING ° ** NOMINAL SSU
SURFACE NA T MAKE -IN DEFLECTOR
I = 6
ir r �, 5
2 -1/4" 2 -3/16° 4
(57,2 mm) 1 = 11 ! (55,6 mm) I
1 � 2
1 -9/16° WRENCH .. 1 d A
u 7 3
(39,7 mm) FLATS ° ■ j �
1
/��� — law
SSP 7
DEFLECTOR CROSS
PENDENT UPRIGHT SECTION
1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame.
Screw * * Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 1
STANDARD RESPONSE SERIES TY-B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS
28 K FACTOR, 1/2 INCH NPT
- ESCUTCHEON 7/16° (11,1 mm) STYLE 10
PLATE SEATING ** NOMINAL RECESSED SSU*
SURFACE tVPT MAKE-IN ESCUTCHEON DEFLECTOR
ai /T 1. ir,•r•,r 1i *�I'R.A 6*
f
. � . = f 5
illr- 7/16"
2-3/16° �� —� � (11,1 mm)
(55,6 mm) 1 1 � NOMINAL 4
MAKE -IN I I� 2
1 -1/2° r�1 2 -3/16" r d r I (55,6 mm) ∎ (38,1 mm) 1, 0 i 3 .
l WRENCH 1 .- W_s
����r _• _. � -. FLATS = j 7
SSP DEFLECTOR — 2-7/8° (73,0 mm) DIA. — "-1 1/2° NPT
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 - Compression orifice seat on frame.
Screw ** Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 2
STANDARD RESPONSE SERIES TY -B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS
5.6 K- FACTOR, 1/2 INCH NPT
1.
TFPI 51 Page 3 of 8
ESCUTCHEON 1/2' (12,7 mm) STYLE 40
PLATE SEATING * * NOMINAL RECESSED *
• SURFACE NPT MAKE -IN ESCUTCHEON DEFLECTOR
_— 6*
� �
1/2° ■
f ° 5
2-5/16" 1111 (12,7 mm)
1 - f - (58,7 mm) / 11= ii � � 7 N AI I 4
° r 2 1 /4° y \ 2
(39,7 mm) WI ��� ttttttt �� (57,2 mm) * 3 1 . WRENCH 1 --- _.. _. _ _ FLATS
1
SSP DEFLECTOR* f— 2-7/B" (73,0 mm) DIA. --" 3/4° NPT
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 - Compression 7 - Ejection orifice seat on frame.
Screw Spring ** Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 3
STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS
8.0 K- FACTOR, 3/4 INCH NPT
_ ESCUTCHEON 7/16" (11,1 mm)
PLATE SEATING 1/2" ** NOMINAL SSU
SURFACE NPT MAKE -IN DEFLECTOR
i \ —_----- .------. 5
, 2 -1/4° � _ � 2 -3/16°
i =1; (57,2 mm) dU ' (55,6 mm) I 1 4
1 -9/16° WRENCH IM1� 1 1I ! 1\ e± 2
(39,7 mm) ' FLATS 7
1
SSP
DEFLECTOR CROSS
PENDENT UPRIGHT SECTION
1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 - Compression orifice seat on frame.
Screw * * Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 4
STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS
8.0 K- FACTOR, 1/2 INCH NPT
Page4of8 TFP151
SPRINKLER FINISH (See Note 8)
K TYPE TEMP. BULB NATURAL CHROME WHITE*" LEAD WAX WAX OVER
LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED
135 °F /57 °C Orange
PENDENT 155 °F /68 °C Red
2.8 (TY1251) 1, 2, 3 N/A
1/2° and 175 °F /79 °C Yellow
NPT UPRIGHT 200 °F /93 °C Green
(TY1151)
286 °F /141 °C Blue
360 °F /182 °C Mauve 1, 2
135 °F /57 °C Orange
PENDENT 155 °F /68 °C Red
(TY3251) 1, 2, 3, 4, 5, 6, 7 1,2,3,5 1,2,3,5 1,2,3,5
and 175 °F /79 °C Yellow
UPRIGHT 200 °F /93 °C Green
5.6 (TY3151)
286°F/141°C Blue 1 ",2 ", 3", 59 1 ", 2 ", 3 ", 5"
1/2°
NPT 360 °F /182 °C Mauve N/A
135 °F /57 °C Orange
RECESSED 155 °F /68 °C Red
PENDENT 1, 2, 3, 4, 5 1, 2, 4, 5 N/A
(TY3251)' 175 °F /79 °C Yellow
Figure 4 200 °F /93 °C Green
135 °F /57 °C Orange
PENDENT 155 °F /68 °C Red
(TY4251) 1,2,5 1,2,3,5 1,2,5
and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6, 7
8.0 UPRIGHT 200 °F /93 °C Green
3/4° (TY4151) -
286°F/141°C Blue 1",2", 3" 5" r 1 " 2 ", 5"
NPT
360 °F /182 °C Mauve N/A
135 °F /57 °C Orange
RECESSED 155 °F /68 °C Red
PENDENT 1, 2, 3, 4, 5 N/A
(TY4251)• 175 °F /79 °C Yellow
Figure 5 200 °F /93 °C Green
135 °F /57 °C Orange
8.0
PENDENT 155 °F /68 °C Red
1/2° and 175 °F /79 °C Yellow 1, 2, 3, 5 N/A
NPT UPRIGHT 200 °F /93 °C Green
(TY4851)
286°F/141°C Blue
360 °F /182 °C Mauve
NOTES:
1. Listed by Underwriters Laboratories, Inc. (UL).
2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL).
3. Approved by Factory Mutual Research Corporation (FM).
4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03).
5. Approved by the City of New York under MEA 354 -01 -E.
6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31- 53 -428- 4444/Fax 31 -53 -428- 3377).
7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05).
8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the
sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated
Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers.
Installed with Style 10 (1/2° NPT) or Style 40 (3/4" NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable.
" 150 °F /66 °C Maximum Ceiling Temperature.
"" Frame and deflector only. Listings and approvals apply to color (Special Order).
N /A: Not Available
TABLE A
LABORATORY LISTINGS AND APPROVALS
•
TFP151 Page 5of8
2 -7/8° DIA. G ,
5/8 ±1/4° (73,0 mm) 3/4 (19,1 mm)
(15,9±6,4 mm) 2 -1/4° DIA. 1/4° (6,4 mm) WRENCH RECESS
(57,2 mm) (END °A° USED FOR
FACE OF MOUNTING 1/2° NPT MODELS)
SPRINKLER PLATE
FITTING
1/8° WRENCH RECESS
•�' (3,2 mm) (END °B° USED FOR
3/4° NPT MODELS)
f � FIGURE 7
W -TYPE 6 SPRINKLER
It ' WRENCH
MOUNTING
SURFACE
WRENCH
CLOSURE SERIES 1 -1/4° (31,8 mm) RECESS
TY-B 3/4" (19,1 mm)
FIGURE 5
SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY
WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT .,
STYLE 10 RECESSED ESCUTCHEON
5.6 K- FACTOR, 1/2 INCH NPT
PUSH WRENCH
IN TO ENSURE
2 -7/8 DIA. ENGAGEMENT
WITH
(73,0 mm) 3/4" (19,1 mm)
5/8 ±1/4° WRENCH N
(15,9±6,4 mm) 2 -1/4° DIA. _ 1/4° (6,4 mm)
FIGURE 8
FACE OF (57,2 mm) MOUNTING W -TYPE 7 RECESSED
SPRINKLER PLATE SPRINKLER WRENCH
FITTING
1/8°
U11. (3,2 mm)
•
I �� t
MOUNT IN G ■
SURFACE
CLOSURE SERIES 1 -5/16° (33,3 mm)
TY-B 13/16° (20,6 mm)
FIGURE 6
SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY
WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON
8.0 K- FACTOR, 3/4 INCH NPT
' Page 6 of 8 TFP151
ing the wax coating. Before wrench
Technical Installation tightening the sprinkler, the jaws of the
wrench are to be adjusted to just con -
Data The Series TY -B Sprinklers must be tact the sprinkler wrench flats. After
installed in accordance with the follow- wrench tightening the sprinkler, loosen
Approvals ing instructions: the wrench jaws before removing the
UL and C -UL Listed. wrench.
FM, LPCB, VdS, and NYC Approved. NOTES After installation, the sprinkler wrench
(Refer to Table A for complete approval Do not install any bulb type sprinkler if p
information including corrosion resis- the bulb is cracked or there is a loss of flats and frame arms must be in-
tant status.) liquid from the bulb. With the sprinkler spected and the wax coating re-
Maximum Workin Pressure held horizontally a small air bubble touched (repaired) whenever the coat -
g should be present. The diameter of the ing has been damaged and bare metal
175 psi (12,1 bar) air bubble is approximately 1/16 inch is exposed. The wax coating on the
Discharge Coefficient (1,6 mm) for the 135 °F /57 °C to 3/32 wrench flats can be retouched by gen-
K = 2.8 GPM /psi (40,3 LPM/barli inch (2,4 mm) for the 360 °F /182 °C tly applying a heated 1/8 inch diameter
K = 5.6 GPM /psi / (80,6 LPM/barlI temperature ratings. steel rod to the areas of wax that have
K = 8.0 GPM /psi / (115,2 LPM/bar1 /2) been damaged, to smooth it back over
A leak tight 1/2 inch NPT sprinkler joint areas where bare metal is exposed.
Temperature Ratings should be obtained with a torque of 7
Refer to Table A to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- NOTES
Finishes mum of 21 ft. lbs. (28,5 Nm) of torque Only retouching of the wax coating ap-
Sprinkler: Reessed Escutcheon: White may be used to install s with plied to the wrench flats and frame
Coated, Chrome Plated, or Brass 1/2 NPT connections. A leak tight 3/4 arms is permitted, and the retouching
Plated inch NPT sprinkler joint should be ob- is to be performed only at the time of
tamed with a torque of 10 to 20 ft.lbs. the initial sprinkler installation.
Physical Characteristics (13,4 (40,7 26,8 Nm). A maximum of 30 The steel rod should be heated
Frame Bronze ft.lbs. Nm of torque only to ue is to be used
Button Brass /Copper to install sprinklers with 3/4 NPT con-
the point at which it can begin to melt
Sealing Assembly nections. Higher levels of torque may the wax, and appropriate precautions
Beryllium Nickel w/Teflont distort the sprinkler inlet and cause need to be taken, when handling the
Bulb Glass leakage or impairment of the sprinkler. heated rod, in order to prevent the
Compression Screw Bronze installer from being burned.
Do not attempt to make -up for insuffi-
Deflector Copper cient adjustment in the escutcheon If attempts to retouch the wax coating
Bushing (K =2.8) Bronze plate by under- or over- tightening the with complete coverage are unsuc-
sprinkler. Readjust the position of the cessful, additional wax can be ordered
sprinkler fitting to suit.
in the form of a wax stick (the end of
which is color coded). Only the correct
Operation The Series TY -B Pendent and Up- color coded wax is to be used, and
The glass Bulb contains a fluid which right Sprinklers must be installed in retouching of wrench flats and frame
g accordance with the following instruc- arms is only permitted at the time of
expands when exposed to heat. When tions. initial sprinkler installation. With the
the rated temperature is reached, the steel rod heated as previously de-
fluid expands sufficiently to shatter the Step 1. Pendent sprinklers are to be p y
glass Bulb, allowing the sprinkler to installed in the pendent position, and scribed, touch the rod to the area re-
activate and water to flow. upright sprinklers are to be installed in quiring additional wax with the rod an
the upright position. gled downward, and then touch the
wax stick to the rod approximately
Design Step 2. With pipe thread sealant ap- one -half inch away from the area re-
plied to the pipe threads, hand tighten quiring retouching. The wax will melt
C riteria the sprinkler into the sprinkler fitting. and run down onto the sprinkler.
Step 3. Tighten the sprinkler into the
The Series TY-B Pendent and Upright sprinkler fitting using only the W -Type The Series TY -B Recessed Pendent
Sprinklers are intended for fire protec- 6 Sprinkler Wrench (Ref. Figure 7), Sprinklers must be installed in ac-
tion systems designed in accordance except that an 8 or 10 inch adjustable cordance with the following instruc-
with the standard installation rules rec- Crescent wrench is to be used for wax tions.
ognized by the applicable Listing or coated sprinklers. With reference to Step A. After installing the Style 10 or
Approval agency (e.g., UL Listing is Figures 1, 2, 3, and 4 the W -Type 7
40
based on the requirements of NFPA Sprinkler Wrench or the adjustable Mounting Plate, as applicable, over
13, and FM Approval is based on the Crescent wrench, as applicable is to the sprinkler threads and with pipe
requirements of FM's Loss Prevention be applied to the wrench flats. thread sealant applied to the pipe
Data Sheets). Only the Style 10 or 40 threads, hand tighten the sprinkler into
Recessed Escutcheon, as applicable, When installing wax coated sprinklers the sprinkler fitting.
is to be used for recessed pendent with the adjustable Crescent wrench, Step B. Tighten the s rinkler into the
installations. additional care needs to be exercised p g p
to prevent damage to the wax coating sprinkler fitting using only the W-Type
on the sprinkler wrench flats or frame 7 Recessed Sprinkler Wrench (Ref.
arms and, consequently, exposure of Figure 8). With reference to Figure 3 or
bare metal to the corrosive environ- 4, the W -Type 7 Recessed Sprinkler
ment. The jaws of the wrench should Wrench is to be applied to the sprinkler
• be opened sufficiently wide to pass wrench flats.
over the wrench flats without damag- Step C. After the ceiling has been in-
TFP151 Page7of8
stalled or the finish coat has been ap- The owner is responsible for the in- -
plied, slide on the Style 10 or 40 Clo- spection, testing, and maintenance of L imited
sure over the Series TY B Sprinkler their fire protection system and de- w arranty
and push the Closure over the Mount- vices in compliance with this docu-
ing Plate until its flange comes in con- ment, as well as with the applicable
tact with the ceiling. standards of the National Fire Protec- Products manufactured by Tyco Fire
tion Association (e.g., NFPA 25), in Products are warranted solely to the
Care and addition to the standards of any other original Buyer for ten (10) years
authorities having jurisdiction. The in- against defects in material and work-
stalling contractor or sprinkler manu- manship when paid for and properly
Maintenance facturer should be contacted relative to installed and maintained under normal
any questions. use and service. This warranty will ex-
The Series TY-B Sprinklers must be pire ten (10) years from date of ship -
maintained and serviced in accord- It is recommended that automatic ment by Tyco Fire Products. No war -
ance with the following instructions: sprinkler systems be inspected,
g components is giv for products by co or
tested, and maintained by a qualified
Inspection Service in accordance with components manufactured by compa-
NOTES P Hies not affiliated by ownership with
Before closing a fire protection system local requirements and /or national Tyco Fire Products or for products and
main control valve for maintenance codes. components which have been subject
work on the fire protection system that to misuse, improper installation, corro-
it controls, permission to shut down the sion, or which have not been installed,
affected fire protection system must be maintained, modified or repaired in ac-
obtained from the proper authorities cordance with applicable Standards of
and all personnel who may be affected the National Fire Protection Associa-
by this action must be notified. tion, and/or the standards of any other
Absence of an escutcheon, which is Authorities Having Jurisdiction. Mate -
used to cover a clearance hole, may vials found by Tyco Fire Products to be
delay the time to sprinkler operation in defective shall be either repaired or
a fire situation. replaced, at Tyco Fire Products' sole
option. Tyco Fire Products neither as-
Sprinklers that are found to be leaking sumes, nor authorizes any person to
or exhibiting visible signs of corrosion assume for it, any other obligation in
must be replaced. connection with the sale of products or
Automatic sprinklers must never be parts of products. Tyco Fire Products
painted, plated, coated or otherwise shall not be responsible for sprinkler
altered after leaving the factory. Modi- system design errors or inaccurate or
fled sprinklers must be replaced. incomplete information supplied by
Sprinklers that have been exposed to Buyer or Buyer's representatives.
corrosive products of combustion, but IN NO EVENT SHALL TYCO FIRE
have not operated, should be replaced PRODUCTS BE LIABLE, IN CON -
if they cannot be completely cleaned TRACT, TORT, STRICT LIABILITY OR
by wiping the sprinkler with a cloth or UNDER ANY OTHER LEGAL THE -
by brushing it with a soft bristle brush. ORY, FOR INCIDENTAL, INDIRECT,
Care must be exercised to avoid dam- SPECIAL OR CONSEQUENTIAL
age to the sprinklers - before, during, DAMAGES, INCLUDING BUT NOT
and after installation. Sprinklers dam- LIMITED TO LABOR CHARGES, RE-
aged by dropping, striking, wrench GARDLESS OF WHETHER TYCO
twist/slippage, or the like, must be re- FIRE PRODUCTS WAS INFORMED
placed. Also, replace any sprinkler that ABOUT THE POSSIBILITY OF SUCH
has a cracked bulb or that has lost DAMAGES, AND IN NO EVENT
liquid from its bulb. (Ref. Installation SHALL TYCO FIRE PRODUCTS' LI-
Section). ABILITY EXCEED AN AMOUNT
EQUAL TO THE SALES PRICE.
Frequent visual inspections are rec THE FOREGOING WARRANTY IS
ommended to be initially performed for
corrosion resistant coated sprinklers, MADE IN LIEU OF ANY AND ALL
after the installation has been corn- OTHER WARRANTIES EXPRESS OR
pleted, to verily the integrity of the cor- IMPLIED. INCLUDING WARRANTIES
rosion resistant coating. Thereafter, OF MERCHANTABILITY AND FIT -
annual inspections per NFPA 25 NESS FOR A PARTICULAR PUR-
should suffice; however, instead of in- POSE.
specting from the floor level, a random
sampling of close -up visual inspec-
tions should be made, so as to better
determine the exact sprinkler condi-
tion and the long term integrity of the
corrosion resistant coating, as it may
be affected by the corrosive conditions
present.
Page 8 of 8 TFP151
P/N 57 -XXX -X -XXX
SPRINKLER TEMPERATURE
MODEL/SIN RATING
530 2.8K UPRIGHT (1 /2 °NPT) TY1151 1 NATURAL BRASS 135 135 °F /57 °C
531 2.8K PENDENT (1 /2 "NPT) TY1251 4 WHITE POLYESTER 155 155 °F /68 °C
570 5.6K UPRIGHT (1 /2 "NPT) TY3151 3 WHITE (RAL9010)° 175 175 °F /79 °C
571 5.6K PENDENT (1 /2'NPT) TY3251 9 CHROME PLATED 200 200 °F /93 °C
590 8.0K UPRIGHT (3/4'NPT) TY4151 7 LEAD COATED 286 286 °F /141 °C
591 8.0K PENDENT (3 /4 "NPT) TY4251 6 WAX COATED 360 360 °F /182 °C
286 °F /141 °C MAX.
560 8.0K UPRIGHT (1 /2 "NPT) TY4851
1 /2 "NP TY4951 8 WAX OVER LEAD
561 8.0K PENDENT
( Tl 286 °F /141 °C MAX.
• Eastern Hemisphere sales only.
TABLE B
PART NUMBER SELECTION
SERIES TY-B PENDENT AND UPRIGHT SPRINKLERS
Recessed Escutcheon: Wax Sticks:
Ordering Specify: Style (specify) Recessed Es- (for retouching wrench damaged
cutcheon with (specify finish), P/N wax coating)
Procedure (specify).
Specify: (Specify color) color coded
When placing an order, indicate the full 1/2' (15 mm) Wax Stick for retouching (specify tern -
product name. Refer to the Price List Style 10 perature rating) temperature rated Se-
° for complete listing of Part Numbers. Chrome Plated P/N 56- 701 -9-010 ries TY-B Sprinklers, P/N (specify).
1/2' (15 mm)
Contact our local distributor for avail- Style 10
Y Black for 135 °F P/N 56-065-1-135
ability. White Colo Red for 155 °F P/N 56 -065 -1 -155
Coated PM 56-701-4-010 Yellow for 175 °F P/N 56 -065 -1 -175
1/2' (15 mm) Blue for 200 °F and
Sprinkler Assemblies with NPT Style 10
Thread Connections: White RAL9010' P/N 56- 701 -3-010 286 °F P/N 56-065-1-286
Specify: (Specify Model /SIN), Stand- 1/2' (15 mm)
and Response, (specify rating), Style 10 NOTES
(specify on rang), S to es 3/4 Brass Plated P/N 56- 701 -2 -010 Each wax stick is suitable for retouch -
TY-B (specify Pendent or Upright) Style 40 ing up to twenty -five sprinklers.
Sprinkler with (specify type of finish or 3/4 m Plated P/N 56- 700 -9-010 The wax used for 286 °F sprinklers is
coating), P/N (specify from Table B). Style 40 the same as for 200 °F sprinklers, and,
White Color therefore, the 286 °F sprinkler is limited
Coated P/N 56-700-4-010 to the same maximum ceiling tempera -
3/4° (20 mm) Lure as the 200 °F sprinkler (i.e.,
Style 40 150°F).
White RAL9010' P/N 56 -700 -3 -010
3/4' (20 mm)
Style 40
Brass Plated P/N 56- 700 -2 -010
• Eastern Hemisphere sales only.
Sprinkler Wrench:
Specify: W -Type 6 Sprinkler Wrench,
P/N 56- 000 -6 -387.
Specify: W -Type 7 Sprinkler Wrench,
P/N 56- 850 -4 -001.
TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446