Permit CITY OF TIGARD BUILDING PERMIT PERMIT #: BUP2001 -00349 �eaN'l'''Iitl DEVELOPMENT H BMEN O ) 639 -4171 DATE ISSUED: 10/3/01 SITE ADDRESS: 12220 SW SCHOLLS FERRY RD PARCEL: 1 S1346C -00300 SUBDIVISION: ZONING: C -G BLOCK: LOT: JURISDICTION: TIG REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: ALT FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 2N : sf N: S: E: W: OCCUPANCY GRP: M TOTAL AREA: 0.00 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: • PARKING: VALUE: $ 300,000.00 Remarks: Commercial tenant improvement - Replacing Suspended Ceiling Owner: Contractor: BPP RETAIL LLC SNODGRASS CONSTRUCTION INC. BY BURNHAM PACIFIC PROPERTIES PO BOX 12146 ATTN: JOHN WATERS PORTLAND, OR 97212 SAN DIEGO, CA 92101 rnone: Phone: 503 - 282 -7255 Reg #: LIC 67637 FEES REQUIRED INSPECTIONS Type By Date Amount Receipt Susp Ceilng Insp PLCK CTR 10/1/01 $989.17 27200100000 Final Inspection FIRE CTR 10/1/01 $608.72 27200100000 PRMT CTR 10/3/01 $1,521.80 27200100000 5PCT CTR 10/3/01 $121.74 27200100000 Total $3,241.43 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -1987. You may obtain a copy of these rules or direct questions to OUNC by calling (503) 246 - s.! • •r 1 -800 344. Permittee i Sign. . re: t1, ei•ai Issu d By: 1 � ,_• . 1 ' .1-&4- ■P Call 639 -4175 by 7 p.m. for an inspection the next business day C� Building PermitApplicatiori �' + _ 1 / o/ Permit no.: u O Date received: / Y;�'�y',, City of Tigard � ' -� 3�9 - - '__ . Project/appl. no.: Expire date: CiryojTigard Address: 13125 SW Hall Blvd, Tigard, OR 97223 n Phone: (503) 639 - 4171 Date issued: By: I Receipt no.: \ Fax: (503) 598 -1960 j °V1/1° ° f l Case file no.: Payment type: ---� Land use approval: l &2 family: Simple Complex: I = TYPE OF PERMIT ❑ 1 & 2 family dwelling or accessory ❑ Commercial/industrial ❑ Multi- family ❑ New construction ❑ Demolition ❑ Addition/alteration/replacement ❑ Tenant improvement ❑ Fire sprinkler /alarm ❑ Other: 1 ' ._ b 'I. • . 1C Job address: /2221 ,5, ( / 0 5 he%l f Bldg. no.: Suite no.: Lot: I Block: (Subdivision: I Tax map /tax lot/account no.: Project name: , 40116 : 5 6A del horn Description and location of work on premises/special conditions: 9/JP. l'41 -PoYA,2 6.40/0 15 .. - • OWNER FOR SPECIAL INFORMATION, USE CHECKLIST Name: %j �j ' ��(( ( Floodplain ,septiccapacity�,sol ; — Mailing address: J /.Z2() 6", t/) , 4 ,) ' . / / l& 2 family dwelling: City: T ' Aid/ State: (xL. I Z P: 2 23 Valuation of work $ Phone: 1 3- D- 76(6/ Fax; �" E -mail: y5/�./a/IL No. of bedrooms/baths Owner's representative: Rik / ; l RC' T� ota numb of floors ,O chd � V Phone:50 rj 1 , I Fax: 13- 'A-14. E -mail: '0 a 11, e G , , $1Vew dwelling area (sq. ft.) APPLICANT Garage/carport area (sq. ft.) Name: a Covered porch area (sq. ft.) (, % / Deck area (sq. ft.) Mailing address: /7,72e1 7, it) ,fi d P. Other structure area (sq. ft.) City: 11 ,/ I State: I ZIP! / Phone: 3 - 7,- 7014 Fax: ', - , ' 5 E - mail: Commercial/industrial/multi- family: CONTRACTOR Valuation of work $ i / ay. Business name: 5/1i 4 , 4 , - T/ie Existing bldg. area (sq. ft.) New bldg. area (sq. ft.) Address: Q /211/6, Number of stories 1 City: 10 r r1O A I State: J/ I ZIP: 212/2_ Phone.`03 Z 7255 I Fax: 435 -3') I E -mail: Type of construction Occupancy group(s): Existing: CCB no.: p tp1 (pal New: City /metro lic. no.: Notice: All contractors and subcontractors are required to be ARCIIITECI7DESIGNER licensed with the Oregon Construction Contractors Board under Name: provisions of ORS 701 and may be required to be licensed in the Address: jurisdiction where work is being performed. If the applicant is City: State: I ZIP: exempt from licensing, the following reason applies: Contact person: Plan no.: Phone: Fax: E -mail: ENGINEER Name: Contact person: Fees due upon application $ Address: Date received: City: (State: (ZIP: Amount received $ Phone: I Fax: I E -mail: Please refer to fee schedule. I hereby certify I have read and examined this application and the Not all jurisdictions accept credit cards, please call jurisdiction for more information. attached checklist. All provisions of laws and ordinances governing this 0 Visa O MasterCard work will be complied ( m� , why t s , - cified herein or not. Credit card number: Ex ires / P Authorized s re: iI ._, /+ 1 Dat e: 0,-/ I � �� I Nam of cardholder as shown on credit card -- Print name: 1sP. 4 r� C 1 ` 3' 5�f)���v Q Cardholder signature $ Amount Notice: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. 440 -4613 (&V0/CoM) 41 7 . ( 7 X6,0? 79- _ * / 5 7 9 ? • COMMERCIAL PLAN SUBMITTAL REQUIREMENT MATRIX Plan review is dependent upon submittal of a completed application and plans. After plan review approval, the Plans Examiner will contact the applicant to request additional plan sets for distribution purposes (for Contractor, City of Tigard, Washington County, and Tualatin Valley Fire & Rescue). Total # of TYPE OF SUBMITTAL Plans KEY: Submitted S = Site Work (must include S (New, Add or Alt) 4 location of all accessible parking) • B (New, Add or Alt) 1* B = Building F (New, Add or Alt) 3 ** F = Fire Protection System M (New, Add or Alt) 2 M = Mechanical P (New, Add or Alt) 2 P = Plumbing E (New, Add, or Alt) 2 E = Electrical New = New Building Add = Addition .Alt = Alteration to existing building *For over - the - counter commercial tenant improvements, submit 2 sets of plans. ** "New" requires that plans bear the original seal of an Oregon licensed fire suppression engineer, or NICET level "3" technicians. I: \dsts \forms\matrxcom.doc 10/27/00 • TABLE 25 -A ° 1997 UNIFORM BUILDING CODE ,. . I, .4._0. --, 0 Fa i v t .fr . /get . ■ • TABLE 25 -A- SUSPENDED AND FURRED CEILINGS • . [For support of ceilings weighing not more than 10 pounds per square foot (4.89 kg /m • MINIMUM SIZES FOR WIRE AND RIGID HANGERS . • Maximum Area • • Supported • (square feet) Size Size and Type - x 0.09 for m x 25.4 for mm • 12.5 0.148 -inch (3.76 mm) (No. 9 B.W. gage) wire 16 0.145 -inch (4.19 mm) (No. 8 B.W. gage) wire Hangers for suspended ceilings 18 7/ diameter, mild steel rod • 20 /32" diameter, mild steel rod 22.5 1 / 4 " diameter, mild steel rod 22.0 1" x 3 /16" mild steel flats ' • ' Single hangers between 8 0.109 -inch (2.77 mm) (No. 12 B.W. gage) wire beams° . 12 0.134 -inch (3.40 mm) (No. 10 B.W. gage) wire 16 0.165 -inch (4.19 mm) (No. 8 B.W. gage) wire . For supporting runners Double wire loops at beams 8 0.083 -inch (2.11 mm) (No. 14 B.W. gage) wire Hangers for attaching or joists 12 0:109-inch (2.77 mm) (No. 12 B.W. gage) wire runners and furring 16 0.120 -inch (3.05 mm) (No. 11 B.W. gage) wire. directly to beams and joists For.supporting furring Type of support: . without runners° (wire Concrete 0.083 -inch (2.11 mm) (No. 14 B.W. gage) wire loops at supports) Steel 8 0.065 -inch (1.65 mm) (No. 16 B.W. gage) wire (2 loops) Wood • 0.065 -inch (1.65 mm) (No. 16 B.W. gage) wire (2 loops) . . MINIMUM SIZES AND MAXIMUM SPANS FOR MAIN RUNNERS Maximum Spacing of Hangers or Supports Maximum Spacing of Runners Size and Type _ (Along Runners) . (Transverse) x 25.4 for mm . x'1.49 for kg /m x 304.8 for mm 3 /4 " - 0.3 pound per foot, cold- or hot - rolled channel 2' • 3' 1 - 0.475 .pound per foot, cold- rolled channel 3' 4' 1 - 0.475 pound per foot, cold - rolled channel 3.5' 3.5' 1 - 0.475 pound per foot, cold - rolled channel 4' . 3' 1 - 1.12 pounds per foot, hot - rolled channel • 4' 5' 2" - 1.26 pounds per foot, hot - rolled channel 5' 5' - 2" - 0.59 pounds per foot; cold - rolled channel 5' 3.5' - 1 x pi,- x 3 /t6�� angle • 5' 3.5' MINIMUM SIZES AND MAXIMUM SPANS FOR CROSS FURRING Maximum Spacing of Runners Maximum Spacing of Cross - furring Members Size and Type of Cross - furring or Supports (Transverse) x 25.4 for mm • • x 1.49 for kg /m x 304.8 for mm x 25.4 for mm 1 /4" diameter pencil rods . 2' 12" • 3 /8" diameter pencil rods 2' • 19" 3 /8" diameter pencil rods 2.5' 12" 3' • 24" • 3 /4" - 0.3 pound per foot, cold- or hot - rolled channel 3.5' • 16" 4' 12" • 4 ' 24 " 1" - 0.410 pound per foot, hot - rolled channel 4.5' • 19" • 5' 12 'Metal suspension systems for acoustical tile and lay -in panel ceiling systems weighing not more than 4 pounds per square foot (19.5 kg/m including light fixtures and all ceiling- supported equipment and conforming to UBC Standard 25 -2, are exempt from Table 25 -A. • 2 All rod hangers shall be protected with a zinc or cadmium coating or with a rust- inhibitive paint. . 3 All flat hangers shall be protected with a zinc or cadmium coating or with a rust- inhibitive paint. • • . °Inserts, special clips or other devices of equal strength may be substituted for those specified. 5 Two loops of 0.049 -inch (1.24 mm) (No. 18 B.W. gage) wire may be substituted for each loop of 0.065 -inch (1.65 mm) (No. 16 B.W. gage) wire for attaching steel furring to steel or wood joists. . 6 Spans are based on webs of channels being erected vertically. • 7 Other sections of hot- or cold - rolled members of equivalent strength may be substituted for those specified. • • 'k 1 -266 . ! , , r!TY OF TIGARD BUILDING INSPECTION DIVISION , '` ` . M F' 24 -Hour Inspec Line: 639 -4175 Business Line: 639 -4171 BU -2 00 l 0 0 349 � r Date Requested /0 — o� AM PM ~ LD Location / rXa 2• d ,�,��4 Suite 6.4-- MEC Contact Person Ph SO 70 Li p PLM Contractor_ Ph SWR LDINa) Tenant/Owner L ELC Re g all ELR Footing Access: Foundation p `� FPS Ftg Drain SGN Crawl Drain Ins.- ion Notes: ,___ Slab ° G � - IT Post & Beam Ext Sheath /Shear / mill • _, Int Sh - -th /Shear ' / Drywall Nailing v a Firewall i ' ,l Fire Sprinkler /� E &G (.O 0 / — C U S7 4 • 6.6 • — Fire Alarm ,? ) cC d-00/ — o& - mi. ,4 c/44 Susp'd Ceiling �� D /� '�• Roof Ci 75 i e� 1 Misc: .1 &2 41 � • Fin • / 44 L ! H a -,- 1- G 0 r 24 011 .■-- 3 -- F p I- f - M 1 ) FAIL • ' `. 71': ' BI G a ( &4 / (.01/4). Post & Beam Under Slab A / —^ -�} Top Out Kr� �i /.V dol_c6 ��� '" +' Water Service d C/ Sanitary Sewer ef f .) ?// �/al i2b WA) Rain Drains F PASS PART FAIL , a..-1, frVLQ r C�✓L ' _ti MECHANICAL Q _ -- c 6---� • r Post & Beam , Rough In se - ' - h- c r7osce r¢/4 Gas Line Smoke Dampers 7 -- 00341 T 2 r Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab yq 7 �j _ ` Low Fire Alarm Voltage f5 AS 7� 1 e ___ — U Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Dat I IV 2;54 k Inspector i1 Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. s . • r _CITY OF TIGARD BUILDING INSPECTION DIVISION MST • , Inspection Line: 63 75 Business Line: 639-4 BUP g 0 Date Requested //7 — .::?- 9 AM PM BLD • Location l 2 Z Z O FAA Suite Rd, MEC Contact Person ql-, Ph _30 7 - 2 - 1 3S PLM Contractor Ph SWR BUILDING Tenant/Owner , .4‘.. vi /� AL-.. s _ ELC Retaining Wall / I ELR Footing Access: Foundation FPS Ftg Drain Crawl in Inspection Notes: SIT ost & Beam Ext Sheath /Shear Int Sheath /Shear Framing I Insulation / Orman I Nailing� i D ` !l iiL All L a. / / i iste' L �'a _ 1 , , Firewall / Fire Sprinkler / ' OA rira ' / / i // � .." Fire Alarm Susp'd Ceiling / If . ' ' // / � - M / I tea' ' /"`� Roof # LL/ / ` IWO. / / E , A t Misc: Fi A SS PART FAIL P BING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - iccess ADA 0 Otheoach /Sidewalk Date /0 -C1 ✓ Inspecto 'F Xt Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CI TIGARD BI IILDING INSPECTION DIVISI( ' MST ' 241-b n�pecfTion Line: ■ -4175 Business Line: 639 -4171 BUP �� 0 y l Date Requested /`)- c / AM PM • i B1GD Location I as d Suite MEC Contact Person Ph 0 7 0 PLM Contract Ph SWR ILDING Tenant/Owner 4 ELC all ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear raming Insu a ion Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: F ASS PART FAIL ING Post & Beam Under Slab /\.) Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line • Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: able to inspect - no access ADA Approach /Sidewalk Other Date �_ 1 �. Dn pector 61/4 Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. 4 CITY OF.TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 c BUP , 1 9/ 0. 0(-3 / Date Requested /al — 3-" AM PM s BLD Location 2 , Suite MEC • Contact Person PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab //;,K4 SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation drywall Nailir Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof M' • OM 'ART FAIL ING I Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL • Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk . Other Date Inspector ` Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD, 24-Hour BUILDING Inspection Line: (503) 639 -4175 • INSPECTION DIVISION Business Line: (503) 639 -4171 MST BUP a ;9° / 6°3 �� Received Date quested PM BUP Location 7 a D /�Ci Suit MEC Contact Person ( ) 3 7 oZ 13S PLM Contractor Ph ( ) SWR BUILDING Tenant/Owner ELC Footing Foundation Access: ELC Ftg Drain ELR Crawl Drain Slab Inspection Notes: / ' • / • SIT Post & Beam G1a� Shear Anchors U C Ext Sheath/Shear Int Sheath/Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd ei i Roof • � PART FAIL p G Post & Beam Under Slab Rough -In ft Water Service Sanitary Sewer Rain Drains Catch Basin / Manhole Storm Drain Shower Pan Other: Final PASS PART FAIL MECHANICAL Post & Beam Rough -In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL • Service Rough -In UG /Slab Low Voltage Fire Alarm Final ❑ Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE ❑ Please call for reinspection RE: Unable to inspect — no access Fire Supply Line / ADA, Approach/Sidewalk Date / I— 2 pector Ext Other: Final DO NOT REMOVE this inspection record from the job site. PASS PART FAIL - CITY OF TIGARD, 24 -Hour BUILDING Inspection Line: (503) 639 -4175 INSPECTION DIVISION Business Line: (503) 639 -4171 MST # BUP 2 65 34-1 Received Date Requested Z AM PM BUP Location f Aff Suite MEC Contact Person Ph ( ) 36 7 1a5 PLM Contractor Ph ( ) SWR BUILDING Tenant/Owner ELC Footing Foundation ELC Access: Ftg Drain ELR Crawl Drain Slab Inspection No s: �b �� , , SIT Post & Beam �' Ext Shear Sheath/Shear th / ear � ,A/114/1.41 1 2 . 4 Ext eah/h IntM h/Shear ra /Insulation � ,�/ la /G • // $ /( Z Clj� r Drywall Nailing ,- Firewall �, l Fire Sprinkler ( / f / Fire s eim Roof Other: F' 'PAW PART gO PLUMBING Post & Beam Under Slab Rough -In Water Service Sanitary Sewer Rain Drains Catch Basin / Manhole Storm Drain Shower Pan Other: Final PASS PART FAIL MECHANICAL Post & Beam Rough -In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough -In UG/Slab Low Voltage Fire Alarm Final ❑ Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE 9 Please call for reinspection RE: ❑ Unable to inspect — no access Fire Supply Line , ADA Approach/Sidewalk Date �� Inspector vir Ext Other: Final DO NOT REMOVE this inspection record rom the Job site. PASS PART FAIL CITY OF TIGARD 24 -Hour BUILDING ' ' Inspection Line: (503) 639 -4175 - INSPECTION DIVISION Business Line: (503) 639 -4171 MS F Bu col DU 3 Lf Received Date Requested a' AM PM - BUP Location / a) Suite MEC Contact Person Ph ( ) 36 -, -t 3.5 PLM Contractor Ph ( ) SWR BUILDING Tenant/Owner ELC Footing Foundation Access: (- c ( " - lac c� . T- �,,,`,4) ELC Ftg Drain ELR Crawl Drain Slab Inspection Notes: SIT Post &Beam e- �1C17. '� C e�-E Shear Anchors - - - �6 Int Sheath/Shear Sheath/Shear Int Framing x Sys Insulation � cA 7 Drywall Nailing ` �1 66�� '' // ' ,' l ,� / s Q�, Firewall i) e D00 / - oc¢Vg- /'t o`-& yrL v44, a Fire Sprinkler J� ^ i Fire Alarm Xhal o- c � S • ) Other: 2' CG C oZ 0 / - 00 S 4 ( F 4 g c.-. C�vr c- c,c/l�/ -1 , Final 3)&7-- C - a — 0 Q G0 c ( 3 Sc,r C.t' ki--"C S PLUMBING 1) U /C 07-00 1 — 00 3 C I`,2 , t -CeS Post & Beam /� //yy c n Under Slab 9 G a / 00 - ? ( (Cx-g l i /Jw I�YI -✓1 4 Rough -In '" ' J -f-wfc...c 5 j i Water Service \ 3 d �i vv l Sanitary Sewer A l Alec Q0 0 ,,._ _ 0 V 04 / �O ( / e__ LO Gc4 �G {- &�2/' Rain Drains \ v ' Catch Basin / Manhole s L, 5 - Storm Drain I ,n,, �-�r \ Shower Pan 1 PGA(. 0 / - 6 Q C 9 ( !� �' l� .3 F I c/Uf 61C 6 -.4..,\ S 4 Other: Final / + - g e l / , v +24.0 d C . ) PASS • ECH PART FAIL Y& C W lJft • W /� . MECHANICAL Post & Beam 4p0-1 ,p_ 0 / - d 3 ci ( T.1' (bG-� l L� _ 0 1 64 /.�i �f Rough -In � J Gas Line (ge- t-C-� �,� a� n r Smoke Dampers ,^� // Final /44i `e .)- SLevCGj QI d- PASS PART FAIL ELECTRICAL oZ 5L-. k r , / Service e e / C./ p Rough -In � A, 4 .-1/) ��j G✓ / "`� -Ire Low ob / / Low Voltage j atIn w ? OFS 1 0 Fire Alarm Final 0 Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE ❑ Please call for reinspection RE: 0 Unable to inspect - no access Fire Supply Line ADA ` n x-1 Approach/Sidewalk Date d �— Inspector V C .. Ext Other: Final DO NOT REMOVE this inspection record from the job site. PASS PART FAIL CITY OF TIGARD 24 -Hour BUILDING Inspection Line: (503) 639 -4175 11WA=' INSPEC ION DIVISION Business Line: (503) 639 -4171 MST 442P (;42°/ - 4°4-711 Received F3 d Date Requested 3 2 " ) 7 6 ?"-• AM PM BUP Location d�cP a S� c �r d !fir Suite MEC Contact Person 6/-€ / e s Ph ( 3) 762— 2-/ 3 S PLM Contractor Ph ( ) SWR '�UILDI 1 Tenant/Owner / V ELC Footing ELC Foundation Access: /J � s - L .-J. '_ /� y f � f Ftg Drain c?� Cam- ' �6' ELR Crawl Drain Slab Inspection Notes: SIT Post & Beam ---- Shear Anchors ______/_ ---'-!-- Ext Sheath/Shear Int Sheath/Shear ,- '` �\ Framing \,. f ' Insulation �, e.�� Drywall Nailing I, � , Firewall ," s 74 i Q L Fire Sprinkler `7 Fire Alarm - ' Susp'd Ceiling Roof ��-- Other: - __ FAIL PLUMBING ( - ' Post & Beam Under Slab > t Rough -In Water Service Sanitary Sewer Rain Drains Catch Basin / Manhole Storm Drain Shower Pan Other: Final PASS PART FAIL MECHANICAL Post & Beam Rough -In Gas Line _ Smoke Dampers Final PASS PART FAIL ELECTRICAL _ Service , Rough -In UG /Slab Low Voltage Fire Alarm Final 0 Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE LI Please call for reinspection RE: 0 Unable to inspect - no access Fire Supply Line 7 ADA / 2 2 - / /t • Inspector Ext ! Approach/Sidewalk Date P Other: Final DO NOT REMOVE this inspection record from the job site. PASS PART FAIL