Permit CITY OF TIGARD BUILDING PERMIT
PERMIT #: BUP2001 -00349
�eaN'l'''Iitl DEVELOPMENT H BMEN O ) 639 -4171 DATE ISSUED: 10/3/01
SITE ADDRESS: 12220 SW SCHOLLS FERRY RD PARCEL: 1 S1346C -00300
SUBDIVISION: ZONING: C -G
BLOCK: LOT: JURISDICTION: TIG
REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION
CLASS OF WORK: ALT FIRST: sf N: S: E: W:
TYPE OF USE: COM SECOND: sf PROJECT OPENINGS?
TYPE OF CONST: 2N : sf N: S: E: W:
OCCUPANCY GRP: M TOTAL AREA: 0.00 sf ROOF CONST: FIRE RET?
OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED:
STOR: HT: ft GARAGE: sf OCCU SEP. RATED:
BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED
FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET:
DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC:
BEDRMS: BATHS: IMP SURFACE: PRO CORR: • PARKING:
VALUE: $ 300,000.00
Remarks: Commercial tenant improvement - Replacing Suspended Ceiling
Owner: Contractor:
BPP RETAIL LLC SNODGRASS CONSTRUCTION INC.
BY BURNHAM PACIFIC PROPERTIES PO BOX 12146
ATTN: JOHN WATERS PORTLAND, OR 97212
SAN DIEGO, CA 92101
rnone: Phone: 503 - 282 -7255
Reg #: LIC 67637
FEES REQUIRED INSPECTIONS
Type By Date Amount Receipt Susp Ceilng Insp
PLCK CTR 10/1/01 $989.17 27200100000 Final Inspection
FIRE CTR 10/1/01 $608.72 27200100000
PRMT CTR 10/3/01 $1,521.80 27200100000
5PCT CTR 10/3/01 $121.74 27200100000
Total $3,241.43
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes
and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is
not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law
requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952 - 001 -0010 through OAR 952 - 001 -1987. You may obtain a copy of these rules or direct questions to OUNC by
calling (503) 246 - s.! • •r 1 -800 344.
Permittee i
Sign. . re: t1, ei•ai
Issu d By: 1 � ,_• . 1 ' .1-&4-
■P
Call 639 -4175 by 7 p.m. for an inspection the next business day
C�
Building PermitApplicatiori �'
+ _ 1 / o/ Permit no.: u O
Date received: /
Y;�'�y',, City of Tigard � ' -� 3�9 -
- '__ . Project/appl. no.: Expire date:
CiryojTigard Address: 13125 SW Hall Blvd, Tigard, OR 97223 n
Phone: (503) 639 - 4171 Date issued: By: I Receipt no.: \
Fax: (503) 598 -1960 j °V1/1° ° f l Case file no.: Payment type: ---�
Land use approval: l &2 family: Simple Complex: I =
TYPE OF PERMIT
❑ 1 & 2 family dwelling or accessory ❑ Commercial/industrial ❑ Multi- family ❑ New construction ❑ Demolition
❑ Addition/alteration/replacement ❑ Tenant improvement ❑ Fire sprinkler /alarm ❑ Other:
1 ' ._ b 'I. • . 1C
Job address: /2221 ,5, ( / 0 5 he%l f Bldg. no.: Suite no.:
Lot: I Block: (Subdivision: I Tax map /tax lot/account no.:
Project name: , 40116 : 5 6A del horn
Description and location of work on premises/special conditions: 9/JP. l'41 -PoYA,2 6.40/0 15 .. -
•
OWNER FOR SPECIAL INFORMATION, USE CHECKLIST
Name: %j �j ' ��(( ( Floodplain ,septiccapacity�,sol ; —
Mailing address: J /.Z2() 6", t/) , 4 ,) ' . / / l& 2 family dwelling:
City: T ' Aid/ State: (xL. I Z P: 2 23 Valuation of work $
Phone: 1 3- D- 76(6/ Fax; �" E -mail: y5/�./a/IL No. of bedrooms/baths
Owner's representative: Rik
/ ; l RC' T� ota numb of floors
,O chd �
V Phone:50 rj 1 , I Fax: 13- 'A-14. E -mail: '0 a 11, e G , , $1Vew dwelling area (sq. ft.)
APPLICANT Garage/carport area (sq. ft.)
Name: a Covered porch area (sq. ft.) (,
% / Deck area (sq. ft.)
Mailing address: /7,72e1 7, it) ,fi d P. Other structure area (sq. ft.)
City: 11 ,/ I State: I ZIP! /
Phone: 3 - 7,- 7014 Fax: ', - , ' 5 E - mail: Commercial/industrial/multi- family:
CONTRACTOR Valuation of work $ i / ay.
Business name: 5/1i 4 , 4 , - T/ie Existing bldg. area (sq. ft.)
New bldg. area (sq. ft.)
Address: Q /211/6, Number of stories 1
City: 10 r r1O A I State: J/ I ZIP: 212/2_
Phone.`03 Z 7255 I Fax: 435 -3') I E -mail: Type of construction
Occupancy group(s): Existing:
CCB no.: p tp1 (pal New:
City /metro lic. no.: Notice: All contractors and subcontractors are required to be
ARCIIITECI7DESIGNER licensed with the Oregon Construction Contractors Board under
Name: provisions of ORS 701 and may be required to be licensed in the
Address: jurisdiction where work is being performed. If the applicant is
City: State: I ZIP: exempt from licensing, the following reason applies:
Contact person: Plan no.:
Phone: Fax: E -mail:
ENGINEER
Name: Contact person: Fees due upon application $
Address: Date received:
City: (State: (ZIP: Amount received $
Phone: I Fax: I E -mail: Please refer to fee schedule.
I hereby certify I have read and examined this application and the Not all jurisdictions accept credit cards, please call jurisdiction for more information.
attached checklist. All provisions of laws and ordinances governing this 0 Visa O MasterCard
work will be complied ( m� , why t s , - cified herein or not. Credit card number: Ex ires /
P
Authorized s re: iI ._, /+ 1 Dat e: 0,-/ I � �� I Nam of cardholder as shown on credit card
-- Print name: 1sP. 4 r�
C 1 ` 3' 5�f)���v Q Cardholder signature $ Amount
Notice: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. 440 -4613 (&V0/CoM)
41 7 . ( 7 X6,0? 79- _ * / 5 7 9 ?
•
COMMERCIAL PLAN SUBMITTAL
REQUIREMENT MATRIX
Plan review is dependent upon submittal of a completed application and plans.
After plan review approval, the Plans Examiner will contact the applicant to
request additional plan sets for distribution purposes (for Contractor, City of
Tigard, Washington County, and Tualatin Valley Fire & Rescue).
Total # of
TYPE OF SUBMITTAL Plans KEY:
Submitted
S = Site Work (must include
S (New, Add or Alt) 4 location of all accessible parking)
•
B (New, Add or Alt) 1* B = Building
F (New, Add or Alt) 3 ** F = Fire Protection System
M (New, Add or Alt) 2 M = Mechanical
P (New, Add or Alt) 2 P = Plumbing
E (New, Add, or Alt) 2 E = Electrical
New = New Building
Add = Addition
.Alt = Alteration to existing
building
*For over - the - counter commercial tenant improvements, submit 2 sets of plans.
** "New" requires that plans bear the original seal of an Oregon licensed fire
suppression engineer, or NICET level "3" technicians.
I: \dsts \forms\matrxcom.doc 10/27/00
•
TABLE 25 -A ° 1997 UNIFORM BUILDING CODE
,. . I, .4._0. --, 0 Fa i v t .fr . /get .
■
• TABLE 25 -A- SUSPENDED AND FURRED CEILINGS • .
[For support of ceilings weighing not more than 10 pounds per square foot (4.89 kg /m •
MINIMUM SIZES FOR WIRE AND RIGID HANGERS
. • Maximum Area • •
Supported
• (square feet) Size
Size and Type - x 0.09 for m x 25.4 for mm •
12.5 0.148 -inch (3.76 mm) (No. 9 B.W. gage) wire
16 0.145 -inch (4.19 mm) (No. 8 B.W. gage) wire
Hangers for suspended ceilings 18 7/ diameter, mild steel rod •
20 /32" diameter, mild steel rod
22.5 1 / 4 " diameter, mild steel rod
22.0 1" x 3 /16" mild steel flats '
• ' Single hangers between 8 0.109 -inch (2.77 mm) (No. 12 B.W. gage) wire
beams° . 12 0.134 -inch (3.40 mm) (No. 10 B.W. gage) wire
16 0.165 -inch (4.19 mm) (No. 8 B.W. gage) wire .
For supporting runners
Double wire loops at beams 8 0.083 -inch (2.11 mm) (No. 14 B.W. gage) wire
Hangers for attaching or joists 12 0:109-inch (2.77 mm) (No. 12 B.W. gage) wire
runners and furring 16 0.120 -inch (3.05 mm) (No. 11 B.W. gage) wire.
directly to beams and
joists For.supporting furring Type of support: .
without runners° (wire Concrete 0.083 -inch (2.11 mm) (No. 14 B.W. gage) wire
loops at supports) Steel 8 0.065 -inch (1.65 mm) (No. 16 B.W. gage) wire
(2 loops)
Wood • 0.065 -inch (1.65 mm) (No. 16 B.W. gage) wire
(2 loops) . .
MINIMUM SIZES AND MAXIMUM SPANS FOR MAIN RUNNERS
Maximum Spacing of Hangers or Supports Maximum Spacing of Runners
Size and Type _ (Along Runners) . (Transverse)
x 25.4 for mm
. x'1.49 for kg /m x 304.8 for mm
3 /4 " - 0.3 pound per foot, cold- or hot - rolled channel 2' • 3'
1 - 0.475 .pound per foot, cold- rolled channel 3' 4'
1 - 0.475 pound per foot, cold - rolled channel 3.5' 3.5'
1 - 0.475 pound per foot, cold - rolled channel 4' . 3'
1 - 1.12 pounds per foot, hot - rolled channel • 4' 5'
2" - 1.26 pounds per foot, hot - rolled channel 5' 5' -
2" - 0.59 pounds per foot; cold - rolled channel 5' 3.5'
- 1 x pi,- x 3 /t6�� angle • 5' 3.5'
MINIMUM SIZES AND MAXIMUM SPANS FOR CROSS FURRING
Maximum Spacing of Runners Maximum Spacing of Cross - furring Members
Size and Type of Cross - furring or Supports (Transverse)
x 25.4 for mm • •
x 1.49 for kg /m x 304.8 for mm x 25.4 for mm
1 /4" diameter pencil rods . 2' 12"
•
3 /8" diameter pencil rods 2' • 19"
3 /8" diameter pencil rods 2.5' 12"
3' • 24" •
3 /4" - 0.3 pound per foot, cold- or hot - rolled channel 3.5' • 16"
4' 12" •
4 ' 24 "
1" - 0.410 pound per foot, hot - rolled channel 4.5' • 19" •
5' 12
'Metal suspension systems for acoustical tile and lay -in panel ceiling systems weighing not more than 4 pounds per square foot (19.5 kg/m including light fixtures
and all ceiling- supported equipment and conforming to UBC Standard 25 -2, are exempt from Table 25 -A. •
2 All rod hangers shall be protected with a zinc or cadmium coating or with a rust- inhibitive paint.
. 3 All flat hangers shall be protected with a zinc or cadmium coating or with a rust- inhibitive paint. • • .
°Inserts, special clips or other devices of equal strength may be substituted for those specified.
5 Two loops of 0.049 -inch (1.24 mm) (No. 18 B.W. gage) wire may be substituted for each loop of 0.065 -inch (1.65 mm) (No. 16 B.W. gage) wire for attaching steel
furring to steel or wood joists. .
6 Spans are based on webs of channels being erected vertically. •
7 Other sections of hot- or cold - rolled members of equivalent strength may be substituted for those specified. •
•
'k 1 -266 .
! ,
, r!TY OF TIGARD BUILDING INSPECTION DIVISION
, '`
` . M F'
24 -Hour Inspec Line: 639 -4175 Business Line: 639 -4171
BU -2 00 l 0 0 349
� r Date Requested /0 — o� AM PM ~ LD
Location / rXa 2• d ,�,��4 Suite 6.4-- MEC
Contact Person Ph SO 70 Li p PLM
Contractor_ Ph SWR
LDINa) Tenant/Owner L ELC
Re g all ELR
Footing Access:
Foundation
p `�
FPS
Ftg Drain SGN
Crawl Drain Ins.- ion Notes: ,___
Slab ° G � - IT
Post & Beam
Ext Sheath /Shear / mill • _,
Int Sh - -th /Shear ' /
Drywall Nailing v a
Firewall i ' ,l
Fire Sprinkler /� E &G (.O 0 / — C U S7 4 • 6.6 • —
Fire Alarm ,? ) cC d-00/ — o& - mi. ,4 c/44
Susp'd Ceiling �� D /� '�•
Roof Ci 75 i e� 1
Misc: .1 &2 41 � • Fin • / 44 L ! H
a -,- 1- G 0 r 24 011 .■-- 3 -- F p I- f - M 1 )
FAIL • ' `.
71': ' BI G a ( &4 / (.01/4).
Post & Beam
Under Slab A / —^ -�}
Top Out Kr� �i /.V dol_c6 ��� '" +'
Water Service d C/
Sanitary Sewer ef f .) ?// �/al i2b WA)
Rain Drains
F PASS PART FAIL , a..-1, frVLQ r C�✓L ' _ti
MECHANICAL Q
_
-- c
6---� • r
Post & Beam ,
Rough In se - ' - h- c r7osce r¢/4
Gas Line
Smoke Dampers 7 -- 00341 T 2 r Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab yq 7 �j _ `
Low Fire Alarm Voltage f5 AS 7� 1 e ___ — U
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk
Other Dat I IV 2;54 k Inspector i1 Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
s .
•
r _CITY OF TIGARD BUILDING INSPECTION DIVISION MST •
, Inspection Line: 63 75 Business Line: 639-4
BUP g 0
Date Requested //7 — .::?- 9 AM PM BLD
•
Location l 2 Z Z O FAA Suite Rd, MEC
Contact Person
ql-, Ph _30 7 - 2 - 1 3S PLM
Contractor Ph SWR
BUILDING Tenant/Owner , .4‘.. vi /�
AL-.. s _ ELC
Retaining Wall / I ELR
Footing Access:
Foundation FPS
Ftg Drain
Crawl in Inspection Notes:
SIT
ost & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing I
Insulation /
Orman I Nailing� i D ` !l iiL All L a. / / i iste' L �'a _ 1 , ,
Firewall /
Fire Sprinkler / ' OA rira ' / / i // � .."
Fire Alarm Susp'd Ceiling / If . ' ' // / � - M / I tea' ' /"`�
Roof # LL/ / ` IWO. / / E , A t
Misc:
Fi
A SS PART FAIL
P BING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - iccess
ADA 0
Otheoach /Sidewalk Date
/0 -C1
✓ Inspecto 'F Xt
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CI TIGARD BI IILDING INSPECTION DIVISI( '
MST '
241-b n�pecfTion Line: ■ -4175 Business Line: 639 -4171
BUP �� 0 y l
Date Requested /`)- c / AM PM • i B1GD
Location I as d Suite MEC
Contact Person Ph 0 7 0 PLM
Contract Ph SWR
ILDING Tenant/Owner 4 ELC
all ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
raming
Insu a ion
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
F
ASS PART FAIL
ING
Post & Beam
Under Slab /\.)
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line •
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: able to inspect - no access
ADA
Approach /Sidewalk
Other Date �_ 1 �. Dn pector 61/4 Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
4 CITY OF.TIGARD BUILDING INSPECTION DIVISION
MST
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 c
BUP , 1 9/ 0. 0(-3 /
Date Requested /al — 3-" AM PM s BLD
Location 2 , Suite MEC
•
Contact Person PLM
Contractor Ph SWR
BUILDING Tenant/Owner
ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab //;,K4 SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
drywall Nailir
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
M' •
OM 'ART FAIL
ING I
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
•
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk .
Other Date Inspector ` Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD, 24-Hour
BUILDING Inspection Line: (503) 639 -4175
•
INSPECTION DIVISION Business Line: (503) 639 -4171 MST
BUP a ;9° / 6°3 ��
Received Date quested PM BUP
Location 7 a D /�Ci Suit MEC
Contact Person ( ) 3 7 oZ 13S PLM
Contractor Ph ( ) SWR
BUILDING Tenant/Owner ELC
Footing
Foundation Access: ELC
Ftg Drain ELR
Crawl Drain
Slab Inspection Notes: / ' • / • SIT
Post & Beam G1a�
Shear Anchors U C
Ext Sheath/Shear
Int Sheath/Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd ei i
Roof
• � PART FAIL
p G
Post & Beam
Under Slab
Rough -In ft
Water Service
Sanitary Sewer
Rain Drains
Catch Basin / Manhole
Storm Drain
Shower Pan
Other:
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough -In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL •
Service
Rough -In
UG /Slab
Low Voltage
Fire Alarm
Final ❑ Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd.
PASS PART FAIL
SITE ❑ Please call for reinspection RE: Unable to inspect — no access
Fire Supply Line / ADA,
Approach/Sidewalk Date / I— 2 pector Ext
Other:
Final DO NOT REMOVE this inspection record from the job site.
PASS PART FAIL
- CITY OF TIGARD, 24 -Hour
BUILDING Inspection Line: (503) 639 -4175
INSPECTION DIVISION Business Line: (503) 639 -4171 MST
# BUP 2 65 34-1
Received Date Requested Z AM PM BUP
Location f Aff Suite MEC
Contact Person Ph ( ) 36 7 1a5 PLM
Contractor Ph ( ) SWR
BUILDING Tenant/Owner ELC
Footing
Foundation ELC
Access:
Ftg Drain ELR
Crawl Drain
Slab Inspection No s: �b �� , , SIT
Post & Beam �'
Ext Shear Sheath/Shear th / ear � ,A/114/1.41 1 2 . 4
Ext eah/h
IntM h/Shear
ra
/Insulation � ,�/ la /G • // $ /( Z Clj� r
Drywall Nailing ,-
Firewall �, l
Fire Sprinkler ( / f /
Fire
s eim
Roof
Other:
F'
'PAW PART gO
PLUMBING
Post & Beam
Under Slab
Rough -In
Water Service
Sanitary Sewer
Rain Drains
Catch Basin / Manhole
Storm Drain
Shower Pan
Other:
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough -In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough -In
UG/Slab
Low Voltage
Fire Alarm
Final ❑ Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd.
PASS PART FAIL
SITE 9 Please call for reinspection RE: ❑ Unable to inspect — no access
Fire Supply Line ,
ADA
Approach/Sidewalk Date �� Inspector vir Ext
Other:
Final DO NOT REMOVE this inspection record rom the Job site.
PASS PART FAIL
CITY OF TIGARD 24 -Hour
BUILDING ' ' Inspection Line: (503) 639 -4175 -
INSPECTION DIVISION Business Line: (503) 639 -4171 MS
F Bu col DU 3 Lf
Received Date Requested a' AM PM - BUP
Location / a) Suite MEC
Contact Person Ph ( ) 36 -, -t 3.5 PLM
Contractor Ph ( ) SWR
BUILDING Tenant/Owner ELC
Footing
Foundation Access: (- c ( " - lac c� . T- �,,,`,4) ELC
Ftg Drain ELR
Crawl Drain
Slab Inspection Notes: SIT
Post &Beam e- �1C17. '� C e�-E
Shear Anchors - - - �6
Int Sheath/Shear Sheath/Shear
Int
Framing x Sys
Insulation � cA 7 Drywall Nailing ` �1 66�� '' // ' ,' l ,� / s Q�,
Firewall i) e D00 / - oc¢Vg- /'t o`-& yrL v44, a
Fire Sprinkler J� ^ i
Fire Alarm Xhal o- c � S • )
Other: 2' CG C oZ 0 / - 00 S 4 ( F 4 g c.-. C�vr c- c,c/l�/ -1 ,
Final 3)&7-- C - a — 0 Q G0 c ( 3 Sc,r C.t' ki--"C S
PLUMBING 1) U /C 07-00 1 — 00 3 C I`,2 , t -CeS
Post & Beam /� //yy c n
Under Slab 9 G a / 00 - ? ( (Cx-g l i /Jw I�YI -✓1 4
Rough -In '" ' J -f-wfc...c 5 j i
Water Service \ 3 d �i vv l
Sanitary Sewer A l Alec Q0 0 ,,._ _ 0 V 04 / �O ( / e__ LO Gc4 �G {-
&�2/'
Rain Drains \ v '
Catch Basin / Manhole s L, 5 -
Storm Drain I ,n,, �-�r \
Shower Pan 1 PGA(. 0 / - 6 Q C 9 ( !� �' l� .3 F I c/Uf 61C 6 -.4..,\ S 4
Other:
Final / + - g e l / , v +24.0 d C . )
PASS •
ECH PART FAIL Y& C W lJft • W /� .
MECHANICAL
Post & Beam 4p0-1 ,p_ 0 / - d 3 ci ( T.1' (bG-� l L� _ 0 1 64 /.�i �f Rough -In � J
Gas Line (ge- t-C-� �,� a� n r Smoke Dampers ,^� //
Final /44i `e .)- SLevCGj QI d-
PASS PART FAIL
ELECTRICAL oZ 5L-. k r , /
Service e e / C./ p
Rough -In � A, 4 .-1/) ��j G✓ / "`� -Ire
Low ob / /
Low Voltage j atIn w ? OFS 1 0
Fire Alarm
Final 0 Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd.
PASS PART FAIL
SITE ❑ Please call for reinspection RE: 0 Unable to inspect - no access
Fire Supply Line
ADA ` n x-1
Approach/Sidewalk Date d �— Inspector V C .. Ext
Other:
Final DO NOT REMOVE this inspection record from the job site.
PASS PART FAIL
CITY OF TIGARD 24 -Hour
BUILDING Inspection Line: (503) 639 -4175 11WA='
INSPEC ION DIVISION Business Line: (503) 639 -4171 MST
442P (;42°/ - 4°4-711 Received F3 d Date Requested 3 2 " ) 7 6 ?"-• AM PM BUP
Location d�cP a S� c �r d !fir Suite MEC
Contact Person 6/-€ / e s Ph ( 3) 762— 2-/ 3 S PLM
Contractor Ph ( ) SWR
'�UILDI 1 Tenant/Owner / V ELC
Footing ELC
Foundation Access: /J � s - L .-J. '_ /� y f � f
Ftg Drain c?� Cam- ' �6' ELR
Crawl Drain
Slab Inspection Notes: SIT
Post & Beam ----
Shear Anchors ______/_ ---'-!--
Ext Sheath/Shear
Int Sheath/Shear ,- '` �\
Framing \,.
f '
Insulation �, e.��
Drywall Nailing I, � ,
Firewall ," s 74 i Q L Fire Sprinkler `7
Fire Alarm - '
Susp'd Ceiling
Roof ��--
Other: -
__ FAIL
PLUMBING ( - '
Post & Beam
Under Slab > t
Rough -In
Water Service
Sanitary Sewer
Rain Drains
Catch Basin / Manhole
Storm Drain
Shower Pan
Other:
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough -In
Gas Line _
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL _
Service ,
Rough -In
UG /Slab
Low Voltage
Fire Alarm
Final 0 Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd.
PASS PART FAIL
SITE LI Please call for reinspection RE: 0 Unable to inspect - no access
Fire Supply Line
7 ADA / 2 2 - / /t • Inspector Ext
!
Approach/Sidewalk Date P
Other:
Final DO NOT REMOVE this inspection record from the job site.
PASS PART FAIL