Loading...
Report Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc • Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330-9155 FAX (503) 684 -0954 FAX (503) 589 -1309 FAX (541) 330 -9163 Special Inspection FINAL SUMMARY LETTER August 25, 2005 T0508339A City of Tigard 13125 SW Hall Blvd., Tigard, OR 97223 -8199 Attn: Building Department Re: NW Pneumatic Office Addition 7190 SW Sandburg Street- Tigard, OR Permit# BUP2005 -0163 . BcPP2 - -oo1 Dear Sir or Madam: This is to certify that in accordance with Section 1701 of the Uniform Building Code, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: Reinforced Concrete Installation of Expansion-Anchors Structural Steel — includes verification of welder certifications, weld procedures and material certifications. Structural Nailing All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there a any further questions regarding this matter, please do not hesitate to contact this office. Respe w" lly submitted, - • - CARL ' %• N TESTING, I • J : s F. Hietpas o • • - -tions Manager H/ks cc: Perlo McCormack Pacific- Scott McCormack VLMK- Greg Blefgen Ankrom Moisan Associated Architects- David Vonada CONSULTING P 503.222.4453 • V L M K ENGINEERS F 503.248.9263 E vlmk @vlmk.com 3933 SW Kelly Avenue • Portland • Oregon 97239 -4393 W www.vlmk.com Noile 1 City of Tigard Building Division 13125 SW Hall Blvd. Tigard, OR 97223 -8189 Re: Perlo McCormack Pacific — Office Addition 7190 SW Sandburg Street #10 Tigard, Oregon 97223 Permit #BUP2005 -0162 To Whom It May Concern: In accordance with Section 1709 of the Oregon State Structural Specialty Code, this letter will serve as the final summary letter for structural observations conducted for the referenced project. VLMK Consulting Engineers was the Structural Engineer of record on this project. Carlson Testing, Inc. completed special inspections in accordance with Section 1701 of the Uniform Building Code. A copy of their Final Summary letter is attached. VLMK Consulting Engineers completed structural observations in accordance with the Special Inspection Program outlined on the City of Tigard approved permit documents. Copies of these reports were forwarded to the city and respective interested parties. To the best of our knowledge, the structural systems for the referenced addition have been completed in accordance with the City of Tigard Approved Plans and Engineer of Record directives. Should you have any questions concerning this summary letter, please do not hesitate to call. Sincerely, M Greg a J. Blefgen, '• . E _ VLMK Consulting veers - Attachment: Carlson Testing, Inc. Final Summary Letter cc: Perlo McCormack Pacific — Scott McCormack GJB:sla I Structural Engineering • Civil Engineering • Industrial Engineering • Planning • Studies / Evaluations • Entitlement G:\Acad205\205154 \CORRESPONDENCE \Letter to City of Tiaard - Perlo 11- 1- 05.doc Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc. Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 684 -0954 FAX (503) 589 1309 FAX (541) 330 -9163 Special Inspection FINAL SUMMARY LETTER October 20, 2005 T0508339 City of Tigard 13125 SW Hall Blvd., Tigard, OR 97223 -8199 Attn: Building Department Re: Perlo McCormack Pacific- Office Addition 7190 SW Sandburg St, #10- Tigard, OR Permit# BUP2005 -0162 Dear Sir or Madam: This is to certify that in accordance with Section 1701 of the Uniform Building Code, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: Reinforced Concrete Installation of Cast in Place Anchors Installation of Expansion Anchors Structural Steel — includes verification of welder certifications, weld procedures and material certifications. Structural Nailing All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If ther= . re any further questions regarding this matter, please do not hesitate to contact this office. Resp • • fully submitt =, CAR ON TES ' G, INC. J • es F. Hietpas • p rations Manager J - /ks : Perlo McCormack Pacific- Scott McCormack VLMK- Greg Blefgen Ankrom Moisan Associated Architects- avid Vonada