Loading...
Correspondence (2) 4 , ,e o 2at9 S - O UO Z. • r CONSULTING 503.222.4453 1 i , ENGINEERS x 503.248.9263 vlrnk @vintk.com 3933 SW Kelly Avenue • Portland • Oregon 97239 -4393 wvrw.vlmk.corn September 1, 2005 Scott McCormack Perlo McCormack Pacific 7190 SW Sandburg Street . Tigard, OR 97223 Re: Perlo and Northwest Pneumatics - HVAC Review 7190 SW Sandburg Street, Tigard, Oregon Dear Scott: At your request, we have completed a structural evaluation for the proposed modifications to the rooftop units over the warehouse portion of the referenced building. This evaluation was based upon the original construction documents as prepared by Norman & Stanich Architects dated January 15, 1971. The as -built mechanical drawings prepared by Temp Control dated July 2, 1987, HVAC plans as prepared Arrow Mechanical Contractors dated June 7, 2005. and our subsequent discussions. As we understand it, the modifications to the proposed facility will entail removing two of the existing units which originally served the warehouse area and the addition of three rooftop units to serve the proposed buildout and the Northwest Pneumatic tenant space. The existing curbs at the removed units will be modified and utilized for two of the rooftop units and the third will require a separate curb. The drawings prepared by Arrow Mechanical present the proposed modifications. The roof structure over the existing facility consists of four inches of vermiculite concrete roof insulation over a 28 -gauge steel form deck supported by open -web steel joists. These steel joists are spaced at four feet on center and are supported at the east and west perimeter concrete walls and an offset open web steel girder line. The joist span at the subject warehouse area is approximately 52 feet. The weight of the new units as identified on the Arrow Mechanical drawings is 483 pounds for the GP3 unit and 589 pounds for the GP4 and GP5 units. Although the exact weight of the existing Trane units which are being replaced was not readily available, it is estimated that these units weigh approximately 25% more than the proposed units. Based upon the information provided, it is easy to draw the conclusion that the existing roof framing will adequately support the proposed rooftop units. I also reviewed the anchorage and attachment of these units with you yesterday. I have attached a structural sketch for the attachment of these units to the roof deck. • 1] Structural Engineering •• Civil Engineering • Industrial Engineering; • Planning • Studies / Evaluations • Entitlement 0..`Acad205 CORRESPO7:0EtlCEIHVAC Rovrew 0.1 -05 dac 0 'Perlo and Northwest Pneumatic - HVAC Review September 1, 2005 Page 2 of 2 • Should you have any questions regarding this letter or the attachments, please do not hesitate to call. 0 PF. Sincerely. C�r�c Fr ri_ , ,a 154;17 • Gregory J. Blefgen, P.E., VLMK Consulting Engineers ,OF1E •4-. �'► F� rY tc �` Attachments: Ry 0�- • GJB:jjs x G; b1ca2205 , 20515•1.CORRESPOi1DEKCEtHVAC Retiiew 0.1.05.Doc 1 4iii 1 : • ' . • C. C. IV:111 CONSULTING 1 r .. c....., G ,-. i_ jt,frele O E N G I N E E R S L..-to-c 3933 SW Kelly Avenue • Portland • Oregon 97239-4393 B 503.222.4453 503.245.9263 E 0,,:-._0 ___ ,,,:-• ;,,Q. . 1 • ; . . , (1 . - • 1 ow . 7z . 6, e4.01/Z i 1 t — '\, \ • ..7t.., 4 9 ... I . , , , 7. I / I \--- i \ I . r i I ' • : - , \ I r : • \ ii I ' - \, I ! I ' \ 1 : t I 1 0 til 4,7 • , / 1 0 . , • 2 . - . I • . 1 ----- N._____-------- - e 12 e, C Ssar2 "ts e / 2 • /- /P-7 1 S . e., _____< - - .- etA 6n . C - e /a13 -----' . . _ • - I Q , — t . . . - - . . * I V . ` /f7,77-oy 2,;? ,V, L 61 "e • • I Fi 72) 4.. p , /yr --1+- . . /i3t,v(aro_f-r.771g- 5 E. • . • , PRat *■.' G INC: j >e, c . " ------ - . "...- 7 e..—:•-_, - .• /b -0- ,4 -c/2- 1--. \%f -p , i "kcialnyo ? ,2_,I.0',--- .,.....___---.__._...................._____,,,