Permit MASTER PERMIT v
CITY OF TIGI4RD DATE 08/4 19 :6- 2:479
COMMUNITY DEVELOPMENT DEPARTMENT
13125 SW Hall Blvd. Tigard. Oregon 97223•8199 (503) 839 -4171 PARCEL: 2S 1 1 iDB- 00200
SITE ADDRESS...: 15284 SW ROYALTY PKWY #C
SUBDIVISION ° WILLOWBROOK FARM /ARBOR HEIGHTS ZONING: R -25 •
BLOC{'. . LOT ............. :8
Remarks: BLDG C, 1 OF 14 MF UNITS
------------ - - - - -- BUILDING - - - - - --
REISSUE: STORIES : 2 FLOOR AREAS BASEMENT...: 2942 sf REQUIRED SETBACKS---- REQUIRED
CLASS OF WORK.:NEW HEIGHT • 0 FIRST • 5884 sf GARAGE 0 sf LEFT • @ SMOKE DETECTRS: V
TYPE OF USE...:MF FLOOR LOAD • 0 SECOND...: 5884 sf FRONT • 0 PARKING SPACES: 0
TYPE OF CONST.:5 -1HR DWELLING UNITS: 20 FINBSMENT: @ sf RIGHT • 0
OCCUPANCY GRP.:R3 BDRM:30 BATH :30 TOTAL - - - - -: 11768 sf VALUE..1: 952946 REAR • 0
---------- - - - - -- --- PLUMBING - --
SINKS • 0 WATER CLOSETS.: 0 WASHING MACH..: 0 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS • 0
LAVATORIES • 0 DISHWASHERS...: 0 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 0 CATCH BASINS..: 0
TUB /SHOWERS...: 0 GARBAGE DISP..: 0 WATER HEATERS.: 0 WATER LINE ft: 0 BCKFLW PREVNTR: 0 GREASE TRAPS..: 0
OTHER FIXTURES: 0
- -------- - - - - -- ------------- - - - - -- MECHANICAL --
FUEL TYPES-- - - - - -- FURN ( 100K ..: 0 BOIL /CNP ( 3HP: 0 VENT FANS • 20 CLOTHES DRYERS: 20
/ELE/ / / FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS • 20 OTHER UNITS...: 20
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS : 0 WOODSTOVES : @ GAS OUTLETS...: 0
- - -- - --- ----------------- - - - - -- - - - - - -- ELECTRICAL
-- RESIDENTIAL UNIT - -- -- SERVICE /FEEDER -- —TEMP SRVC /FEEDERS -- -- BRANCH CIRCUITS - -- - - -- MISCELLANEOUS - - -- - -ADD'L INSPECTIONS- -
1000 SF OR LESS: 0 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500Sf.: 0 201 - 400 alp..: 0 201 - 400 amp..: 0 1st W/G SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0
LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT 0
MANF HM/SVC/FDR: 0 601 - 1000 amp.: 0 601 +amps -1000 v: 0 MINOR LABEL -10: 0
1000+ amp /volt.: 0. PLAN REVIEW SECTION ------- - - - ---
Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC:
- - -- - - -- --- -- ELECTRICAL - RESTRICTED ENERGY
A. SF RESIDENTIAL-------- - - - - -- B. CONMERCIAL - - - - -- - - - - --
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: 0TH: at BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: .•
HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0
Owner: Contractor: ----- - - - - -- TOTAL FEES:$ 16845.46
SECURITY CAPITAL PACIFIC TRUST CONTRACTOR NOT ON FILE
SUITE 201
330 112TH AVE., NE
BELLEVUE WA 98004
Phone #: 206 -451 -9292 Phone #:
Reg #..:
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other
applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180
days of issuance, or if work is suspended for more than 180 days.
- - - - -- -- REQUIRED INSPECTIONS -- - - - - -- -- - - - - --
Post /Beam Mechan Foundation Insp Plm /Underfloor Plumbing Top Out Gyp Board Insp Sprinkler Underf
PLM /Underfloor Erosion Control Crawl Drain Framing Insp Rain Drain Insp Sprinkler Rough -
Mechanical Final Wtr Proofing Bsm Slab Insp Insulation Insp Water Line Insp Sprinkler Final
Plumb Final Post /Beam Struct Plm /ands Insp Shear Wall Insp Water Service In Smoke Detector
Footing Insp Post/Beam Median Mec al 1 Firewall Insp Appr /Sdwlk Insp Additional.. ...
Permittee Signature: _ — issued By '/ i41 1 ,4, '4
Call for inspection — 639 -4175 1
. CITY OF TIGARD MASTER PERMIT
PERMIT # ^ MST96 -01Z179
COMMUNITY DEVELOPMENT DEPARTMENT DATE ISSUED: 09/24/96
13125 SW Hall Blvd. Tigard, Oregon 97223.8199 (503) 839 -4171
PARCEL: 2S 1 1 @DN -0m2vm
SITE ADDRESS...: 15284 SW ROYALTY PKWY #C
SUBDIVISION • WILLOWBROOK FARM /ARBOR HEIGHTS ZONING: R -25
BLOCK LOT .A
Remarks: BLDG C, 1 OF 14 OF UNITS
---------- - - - - -- ---- - - - --- BUILDING ----- -
REISSUE: STORIES • 2 FLOOR AREAS - BASEMENT...: 2942 sf REQUIRED SETBACKS - - -- REQUIRED
CLASS OF WORK. :NEW HEIGHT • 0 FIRST • 5884 sf GARAGE 0 sf LEFT • 0 SMOKE DETECTRS: Y
TYPE OF USE...:MF FLOOR LOAD : 0 SECOND...: 5884 sf FRONT • 0 PARKING SPACES: 0
TYPE OF CONST.:5 -1HR DWELLING UNITS: 20 FINBSMENT: 0 sf RIGHT • 0
OCCUPANCY GRP.:R3 BDRM:30 BATH:30 TOTAL - --- -: 11768 sf VALUE..$: 952946 REAR • 0
-- - - - - -- PLUMBING ----- - - - - -- --- - - - - --
SINKS • 0 WATER CLOSETS.: 0 WASHING MACH..: 0 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS : 0
LAVATORIES • 0 DISHWASHERS...: 0 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 0 CATCH BASINS..: 0
TUB /SHOWERS...: 0 GARBAGE DISP..: 0 WATER HEATERS.: 0 WATER LINE ft: 0 BCKFLW PREVNTR: 0 GREASE TRAPS..: 0
OTHER FIXTURES: 0
- -- - - ---- ----------- - - - - -- -- - - - - -- MECHANICAL —
FUEL TYPES FURN (100K ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS • 20 CLOTHES DRYERS: 20
/ELE/ / / FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS • 20 OTHER UNITS...: 20
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES • 0 GAS OUTLETS...: 0
- -- - - -- ---- - - - - -- ELECTRICAL ------------------------------------ ---
- -RESIDENTIAL UNIT -- -- SERVICE /FEEDER - - -- - -TEMP SRVC /FEEDERS -- -- BRANCH CIRCUITS - -- - -- MISCELLANEOUS - - -- - -ADD'L INSPECTIONS- -
PA0 SF OR LESS: @ 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FOR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 0 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR : 0
LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 alp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT 0
MANF HN /SVC /FDR: 0 601 - 1000 amp.: 0 601 +amps- 1%0 v: 0 MINOR LABEL -10: 0
1m+ amp /volt.: @ - ------ - - - - -- PLAN REVIEW SECTION - - ---- - - --
Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CtS AREA /SPC GEC:
- - - -- ----------------------- ---- -- ELECTRICAL - RESTRICTED ENERGY - ---
A. SF RESIDENTIAL— --- --- - -- B. COMMERCIAL
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: 0TH: :: BOILER HVAC LANDSCAPE /IRRI6: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: ::
HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0
Owner: - Contractor: TOTAL FEES:$ 16845.46
SECURITY CAPITAL PACIFIC TRUST DONALD M DRAKE CO
SUITE 201 1740 NW FLANDERS ST
330 112TH AVE., NE
BELLEVUE WA 98004 PORTLAND OR 97209
Phone #: 206- 451 -9292 Phone #: 620 -0868
Reg #..: 084045
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other
applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180
days of issuance, or if work is suspended for more than 180 days.
----- - - - - -- - - - -- - - -- REQUIRED INSPECTIONS ----------------
Post /Beam Mechan Foundation Insp Plm /Underfloor Plumbing Top Out Gyp Board Insp Sprinkler Underf
PLM /Underfloor Erosion Control Crawl Drain Framing Insp Rain Drain Insp Sprinkler Rough -
Mechanical Final Wtr Proofing Bs. Slab Insp Insulation Insp Water Line Insp Sprinkler Final
Plumb Final Post /Beam Struct Plm /undslb Insp Shear Wall Insp Water Service In Smoke Detector
Footing Insp Post /Beam Mechan Mechanical Insp Firewall Insp Appr /Sdwlk Insp Additional
Permittee Signature: ' r rv �— Issued By: —
Call for inspection — 639 -4175
Page No. 1 CASE HISTORY FOR CASE NO.: MST96 -0079
SECURITY CAPITAL PACIFIC TRUST
15284 SW ROYALTY PKWY Unit: C
12/30/97
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA026 Plans approved by Plans Exmr / / / / 04/01/96 PASS MS 04/01/96 MRS
MSTA711 Post /Beam Mechanical / / / / / / 03/10/96 J *H
MSTA717 PLM /Underfloor / / / / 10/02/97 Note: TLP 11/25/97 J *H
A letter from the engineer of this job
required to show all underfloor work
completed and or corrected per plan.
This letter is required for every
•
building on this project plus a copy of
alarm test from signal /monitor station.
Called contractor 102297, he said he
will send infor asap.
MSTA795 Mechanical Final / / / / 08/25/97 see framing this date FAIL RB 08/26/97 RB
MSTA797 Plumb Final / / / / / / 03/10/96 J *H
MSTB005 Application received / / / / 02/21/96 PASS JH 05/03/96 BT2 •
MSTB008 Permit created / / / / 05/03/96 PASS JF 05/03/96 BT2
MSTB010 Check for prcl. restrict. / / / / / / 03/10/96 J *H
MSTB012 Plans routed to Plans Examiner / / / / / / 03/10/96 J *H
MSTB026 Plans approved by Plans Exmr / / / / 03/20/96 PASS MJR 03/20/96 MJR
MSTB026 Plans approved by Plans Exmr 05/03/96 / / 06/04/96 APPR JHP 06/05/96 JHF'
MSTB030 Reviewed plans routed to DSTS / / / / 03/20/96 letter attached YES MJR 05/03/96 BT2
MSTB030 Reviewed plans routed to DSTS 05/03/96 / / 06/04/96 hold permit until owner has submitted APPR JHF 06/05/96 JHP
-
two spl insp. forms
MSTB065 Hold for Pre -Job Conf / / / / / / 03/10/96 J *H
MSTB090 (F) Ready to issue / / / / 08/06/96 APPR JMH 08/06/96 J•H
MSTB098 (F) Issue combination permit / / / / 08/22/96 APPR JMH 08/22/96.J *H
MSTB105 (F) Reprint Permit / / / / 08/24/96 08/24/96 J *H
MSTB410 Devel review cond. met / / / / / / 03/10/96 J *H
MSTB705 Footing insp / / / / 02/05/97 Building C footing concrete report PASS PSI 11/25/97 J *H
received from PSI Env. Geo. Construction
Engineers. Per report, tests comply with
specs.
MSTB706 Foundation Insp / / / / 02/05/97 all spot footings to be reinspected PASS TLP 02/05/97 TLP
after pour these eights appear to be
disturbed •
MSTB709 Wtr Proofing Bsm't Walls / / / / / / 03/10/96 J *H
MSTB710 Post /Beam Structural / / / / 04/07/97 all bolting to be completed and PART TLP 04/08/97 TLP
reinspected.
MSTB711 Post /Beam Mechanical / / / / / / 03/10/96 J *H
MSTB712 Plm /Underfloor / / / / 04/07/97 PASS TLP 04/08/97 TLP
MSTB713 Crawl Drain / / / / / / 03/10/96 J•H
Page No. 2 CASE HISTORY FOR CASE NO.: MST96 -0079
• SECURITY CAPITAL PACIFIC TRUST
15284 SW ROYALTY PKWY Unit: C
12/30/97
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
•
•
MSTB715 Slab Inep / / / / / / 03/10/96 J *H
MSTB720 Plm /undslb Insp / / / / / / 03/10/96 J *H
MSTB725 Mechanical Insp / / / / 08/25/97 no record of plumbing /electrical covers- FAIL RB 08/26/97 RB
unable to, make framing
mech inspection made- 2 issues
dryer vening exceeds limitations
seal all joints of range venting
electrical heat- 0 ductwork noted
MSTB725 Mechanical Insp / / / / 08/26/97 see framing this date $ 15 RB 11/25/97 J *H
MSTB727 Plumbing Top Out / / / / 08/08/97 PASS RAB 08/08/97 RAB
MSTB730 Framing Insp / / / / 08/25/97 see mech inspection this date FAIL RB 08/26/97 RB
MSTB730 Framing Inep / / / / 08/26/97 mech issues un- resolved as per this FAIL RB 11/25/97 J *H
date, reinepection fee of $15.00 due
dryer venting may need boosters;
insulation covering range venting -
unable to view.
REMOVE ALL INSULATION, AS TO ALLOW FOR
FRAMING INSPECTION
•
•
•
G
Page No. 3 CASE HISTORY FOR CASE NO.: MST96 -0079
SECURITY CAPITAL PACIFIC TRUST
15284 SW ROYALTY PKWY Unit: C
•
12/30/97
Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTB745 Insulation Insp / / / / 08/29/97 FRAMING & MECHANICAL: FAIL RB 09/01/97 J *H
UNIT 1:
1. Firestoop at all areas marked.
2. Strap plates where marked.
3. Provide vapor barrier at all exterior
walls.
UNIT 2:
1. Firestop at all areas marked.
2. Enclose lid at unusable space at main
entry.
UNIT 3:
1. Firestop at all areas marked.
2. Enclose lid at unusable space at main
entry.
UNIT 4:
1. Firestop at all areas marked.
2. Strap plate where marked.
3. Vapor barrier missed.
COMPLETE ? AT 1, 2, 3
DRYER VENTING: 1 =33' W/O VERTICAL RISE,
1 -90
2 =39' W/O VERTICAL RISE, 2 -90
3 =38' W/O VERTICAL RISE, 2 -90
4 =31.5 W/O VERTICAL RISE, 1 -90
1 -4 DRYER VENTING IN ACCORDANCE WITH
DRYER SPEC'S - OK /RB
Previous report dated 082797 incomplete
issues, i.e. straps at plates, lid
unusable space compartments, etc.
Please maintain corrections, pay
reinspection fee $30.00, and call for
reinspection.
Insulation incomplete as per units 1 -4;
terminated inspection.
Mech rough -in approval will be
determined by dryer vent measurements.
MSTB750 Shear Wall Insp / / / / 07/09/97 PASS TLP 07/30/97 J *H
MSTB755 Firewall Inap / / / / / / 03/10/96 J *H
MSTB760 Gyp Board Inap / / / / 09/12/97 PASS RB 11/25/97 J *H
MSTB779 Rain Drain Insp / / / / 04/07/97 PASS TLP 04/08/97 TLP
MSTB780 Water Line Insp / / / / 04/30/97 PASS TLP 05/01/97 TLP
MSTB785 Appr /Sdwlk Inap / / / / / / 03/10/96 J *H
MSTB791 «REINSPECTION» / / / / 08/26/97 MECH ROUGH AND FRAMING FAILURES $ 30 RB 08/26/97 RB
Page No. 4 CASE HISTORY FOR CASE NO.: MST96 -0079
SECURITY CAPITAL PACIFIC TRUST
15284 SW ROYALTY PKWY Unit: C
12/30/97
Action Description Reg/ Schd/ End/ Action Notes Die') By Update Upd
Code Sent Done Done Date By
MSTB797 Plumb Final / / / / 11/25/97 Approved pending caulking the floors in PASS MS 11/25/97 J *H
front of tubs.
MSTD095 Issue plumbing signature form / / / / 04/23/97 RECD SIGN PLM FORM PASS JT 04/23/97 RB
MSTD097 Issue Electric Signature Form / / / / 04/28/97 REC'D SIGN ELEC FORM PASS JT 04/28/97 RB
MSTD723 Electrical Service 08/25/97 / / 09/16/97 PASS BRP 09/17/97 J *H
MSTD724 Electrical Rough -in 08/25/97 / / 08/22/97 Rough -in approved, no signature form, PASS BRP 08/25/97 J *H
service not inspected -,not ready
MSTD725 Mechanical Inep 08/27/97 / / 08/27/97 Reinspection fees unpaid. FAIL RB 08/27/97 J *H
MECHANICAL:
1. Contingent to dryer spec's listing,
• using 2- elbows, specs received.
FRAMING:
1. Protect electrical boxes within
24- inches in same stud bya between units
in firewalls.
2. Firecaulk all firewall through hole
penetrations. Rockw001 okay.
3. When first layer of rock behind
• shower abutte firewall, the 1st layer
needs to extedn flush with ceiling >
then ceiling, then second layer as
follows (see illustration). Firetape!
Correct method.
4. At bottom of coat. closet > ceiling •
needs to have a lid > firestopping
issue. Dead cavity, noted locations.
5. Firestop/block off floor cavity at
exhaust venting in bathrooms. Firestop
all thru'hole penetrations within.
6. All units to be used for adaptable
unite: Provide blocking at showers and
water closets, etc.
OKAY TO INSULATE.
MSTD727 Low Voltage 08/25/97 / / 11/19/97 PASS MJR 11/20/97 MJR
MSTD730 Framing Insp 08/27/97 / / 08/27/97 See mech notes this date. FAIL RB 08/27/97 J *H
•
MSTD745 Insulation Insp / / / / 09/03/97 Told Mike to take pictures of PASS GS 09/07/97 J *H
corrections.
1'•
• Page No. 5 CASE HISTORY FOR CASE NO.: MST96 -0079
SECURITY CAPITAL PACIFIC TRUST
•
15284 SW ROYALTY PKWY Unit: C
12/30/97
. Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTD760 Gyp Board Inep / / / / 09/11/97 1. Unknown if RC channel was inspected FAIL RB 09/14/97 J +H
or approved.
2. Unknown if let layer of 2 -hr.
firewall has been inspected or approved.
3. Replace white board with green board
at all bathrooms.
4. Missed nailing through -out.
5. Studs (or) gyp milers missing
through -out.
MSTD795 Misc. Inspection / / / / 09/03/97 Re -bar length and elevation okay - UFER PASS BRP 09/03/97 J•H
approved.
MSTD796 Electrical Final 08/25/97 / / 11/19/97 ground Kit. light fixtures and mount per MJR MJR 11/20/97 MJR
listing
MSTD798 Mechanical Final 12/02/97 / / 11/26/97 PASS TLP 12/02/97 J*H
MSTD799 Building Final 12/02/97 / / 11/26/97 holding processing C/O until bup96 -0360, PASS TLP 12/30/97 JT
bup96 -0239, garage & spklr have approved
finals. I requested finals on these two
for 12/29/97. jeanne t.•
12/30/97 to Jill for C/O approval
Oft
•
15.1)
•
vste
•
•
CITY OF TIGARD BUILDING INSPECTION NOTICE
Inspection Line: 639 -4175 Business Phone: 639 -4171
Footing Rain Drain Cover /Service FIN
Foundation Water Line Ceiling - Plumb.
Post/Beam Mech. Shear /Sheath Framing -Mech.
Plbg.Und /FIr /Slab Plbg. Top Out Insulation - Elect.
Post/Beam Struct. Mech. Rough -in Gyp. Bd. -Bldg.
Gas Line Appr /Sdwlk Reins.
Other: C
::ss: / 5 2. W -41. •
Tenant: S : M :'' CO /7
S <f7g8 MEC:
c� ! MEC :
PLM:
ELC:
THE FOLLOWING CORRECTIONS ARE REQUIRED: ELR:
Ins ctor: ; /! -_ Date:g449 7
APPROVED DISAPPROVED /CALL FOR REINSP. CF CO
k f.-- 152 CITY OF TIGARD BUILDING INSPECTION DIVISION
24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171
Date Requested: //— 5 �-. 97 A.M. P.M. MST: 96 -067?
Location: /52 SG(/ ) ,/f U OJI C, - Ahai ("7„, BUP:
Tenant: R /�— *1775 Suite: p Bldg: MEC:
Contractor: ,4C/ L , i'l Phone: S90 - y7 92 PLM:
,
Own- : . Phone: ELC:
/ 5;i /` /A ' J... . ' ` & : J ELR:
/ ,
BUILDING BLDG (con't) ' I , ! : !• : /' MECHANIC • E ' CTRICAL SITE aF W/07
Site Post/Beam Post/Beam Post/Beam Cover /Service Sewer /Storm
Footing Roof UndFl/Slab Rough -In Ceiling Water Line
Slab Framing Top Out Gas Line Rough -In UG Sprinkler
Foundation Insulation Sewer Hood/Duct Reconnect Vault
Bsmt Damp Drywall Storm Furnace Temp Service MISC.
Masonry Ceiling Rain Drain A/C UG Slab
Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Volt
Approved ( pro Approved Approved Approved
Appr /Sdwlk Not Approved roved Not Approved Not Approved Not Approved
FINAL FINAL ' FINAL FINAL FINAL
F Y/ - ke49c // , (z/ tt dew 7 U 74/
60r 2 tzC,r .dr 1 ,
-/-itc)
. // /--, ,
r
I
O Call for reinspection O Reinspection fee of $ required before next inspection O Unable to inspect 11-72/1
Inspector: Date: / 5 Page_/ of
L. . „
l
.x'10/23/1997 14:09 503 -620 -2222 DRAKE /DUNN -ARBOR PAGE 01
16204 RDY ,11 .
DRAKE /DUNN
Prf\ico (z-- • 0-7-1--s 0
FAX TRANSMITTAL
&1
Q
TO: P COPIES TO:
/oM
COMPANY: (,,c 27.1441 — /3 • ZPr
DMD -
HO
FAX NO.:` Z 7 DMD - Jobsite
FROM: Bruce Van Hine DATE SENT: / 0/23 /97
COMPANY: Drake /Dunn TIME SENT: . Z PM
NUMBER TO CONFIRM RECEIPT: (503) 620 -0868 SENT BY: ?VW
NUMBER TO RESPOND BY FAX: (503) 620 -2222
I
NUMBER OF PAGES INCLUDING THIS SHEET: Z
SUBJECT: ARBOR HEIGHTS APARTMENTS //''
Allri rw o TAB^ (az /Zee f'` ,//d0/1$.
COMMENTS:
n'o,e ii',s 7, 4,e6r („2ti crf itze weeds
d r-r- "`" --
DRAKE'DUNN Joint Venture, 437 North Columbia Boulevard. Portland. Oegor .9721 7
(503)978 -0800 FAX (503)978 -1031
7 111
10/23/1997 14:09 503- 620 -2222 DRAKE/DUNN-ARBOR PAGE 02
�%T -23 -139? 12:12 0 .32
_ " CONLEE ,>� e 8,1.
t: Pomona, Omen 97219
>c t ENGINEERS, INC. FAX (503) 244�i023
MEMO
DATE: October 23, 1991
TO: Bruce Van Hine
Drake
FROM: Doug Gannet!
Conies Engineers, Ihc.
RE: Arbor Heights
Please note that we have made a cursory inspection of all buildings for general conformance
with our design requirements. As was noted in our reports dated 12/18197, 2118/97, 3/5/97,
412/97, 4122197. 6/71'87 and 6127/97, some problems were found. To the best of our
knowledge, you have addressed ti,ese items.
CC: Gary Truitt - Security Capital
File - RA11023.97
TITRL :1'.0-*
21
Jo/ •
/ CI TY OF TIGARD BUILDING INSPECTION DIVISION
24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171
Date Requested: t/ t/•Ct/l.- • 1- .?-C -9 7 A.M. P.M. MST: Z 7?
Location: 41 - a _ e- A...//A...//_i (, ' / , L l BUP:
Tenant: 140e /2--- /
Suite: t ^ y Bldg: MEC:
Contractor: &t t ce — l / �� Phone: ' 6 PLM:
O wner: DT2,4,� c(J CEO ,�f hone: ELC:
. >0.li.% .(r—P 7AP r&4 • ELR:
SIT:
BUILDING BLDG ( on't) PLUMBING/ I VI: MI CM:l Mr ELECTRICAL SITE
Site .':earn Post/Beam •o 1 : eam Cover/Service- Sewer /Storm
Footing Roof UndFl/Slab Rough -In Ceiling Water Line
Slab Framing Top Out Gas Line Rough -In UG Sprinkler
Foundation Insulation Sewer Hood/Duct Reconnect Vault
Bsmt Damp Drywall Storm Furnace Temp Service MISC.
Masonry Ceiling Rain Drain A/C UG Slab
Shear /Sheath Fir - • . • Crawl/Found Dr Heat Pump Low Volt
Approved Approved • ..rov . . Approved Approved
Appr /Sdwlk " .. a. oved Not Approved , o • ..roved Not Approved Not Approved
FIN FINAL FINAL FINAL
I
O Call for reinspec ' . n �� D Reinspection fee of $ required before next inspection Cl Unable to inspect
7 Inspector: � Date: / -2C' / Page of
1S 51
CITY OF TIGARD BUILDING INSPECTION DIVISION
24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171
Date Requested: ! 1 — I C 7 C ( 7 A.M. P.M. MST: q6-0679'
Location: 16.;--gLi-- Siit) IZOZCP O _ Pk.( j- BUP:
Tenant: AR-13 6 t - H -- S 0 Suite: Bldg: Cj MEC:
Contractor: f, O 1J Fj 2 p t Phone: 5 gg/ - c/016 PLM:
Owner: Phone: ELC:
ELR:
SIT:
BUILDING BLDG (con't) PLUMBING MECHANICAL /LECTRICAL ' SITE
Site Post/Beam Post/Beam Post/Beam Cover Sewer /Storm
Footing Roof UndFl/Slab Rough -In Ceiling Water Line
Slab Framing Top Out Gas Line Rough -In UG Sprinkler
Foundation Insulation Sewer Hood/Duct Reconnect Vault
Bsmt Damp Drywall Storm Furnace Temp Service MISC.
Masonry Ceiling Rain Drain A/C UG Slab
Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Volt
Approved Approved Approved Approve % Approved
Appr /Sdwlk Not Approved Not Approved Not Approved of A1proved Not Approved
FINAL FINAL FINAL FINAL
r / r ( t ■ 4... f-
J r - 7 4 t
0 or — / C _ ..
? 4i P r- c ‘2` /`_ TC a, e -P L'. k c�v`; ,,j
/ i 1 .t-PS—
/ ` S
•
0
O Call for reinspection O Reinspection fef of $ required before next inspection O Unable to inspect
Inspector: A i C 49e- ( RvLeiel Date: / ( / / 1 F7 Page 1 of 7