Permit _ ______-
CITY OF T IGARD PERMIT BUILDING # PERMIT
• BUP96- 1Z1241
COMMUNITY DEVELOPMENT DEPARTMENT DATE ISSUED: 08/22/96
13125 SW Hell Blvd. Tigard, Oregon 97223.8199 (503) 839 -4171
PARCEL: 2911 0D8- 0020111
SITE ADDRESS...: 15187 SW ROYALTY PKWY #E
SUBDIVISION • WILLOWBROOK FARM /ARBOR HEIGHTS ZONING:R -25
BLOCK • LOT •8
REISSUE: FLOOR AREAS - -- EXTERIOR WALL CONSTRUCTION -
CLASS OF WORK.: NEW FIRST • 90111 sf N: S: E: W:
TYPE OF USE...: MF SECOND...: 0 sf PROTECT OPENINGS? - - - - --
TYPE OF CONST. : 5N .... 0 sf N: S: E: W:
OCCUPANCY GRP.:M1 TOTAL. 900 sf ROOF CONST: FIRE RET ?:
OCCUPANCY LOAD: 0 BASEMENT.: 0 sf AREA SEP. RATED:
STOR.: 0 HT: 0 ft GARAGE...: 0 sf " OCCU SEP. RATED:
BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED - - --
FLOOR LOAD • 0 psf LEFT: 0 ft RGHT: 0 ft FIR SPKL:N SMOK DET..:N
DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM:N HNDICP ACC:
BEDRMS: 0 BATHS: 0 IMP SURFACE: 0 PRO CORR:N PARKING: 0
VALUE. $ : 15390
Remarks: GARAGE 5 NEAREST BUILDING E
Owner : -- -. FEES ---
CAPITAL PACIFIC TRUST type amount by date recpt
SUITE 201 PRMT $ 116.50 CJS 08/22/96 96- 283180
330 112TH AVE. , NE PLCK $ 75.73 CJS 08/22/96 96-- 28318121
BELLEVUE WA 98004 FIRE $ 46.60 CJS 08/22/96 96- 283180
Phone #: 206- 451 -9292 5PCT $ 5.83 CJS 08/22/96 96- 283180
EROS $ 26.00 CJS 08/22/96 96- 283180
Contractor: - - -- -- -. ERPC $ 8.45 CJS 08/22/96 96- 283180
DONALD M DRAKE CO ERPC $ 8.45 CJS 08/22/96 96- 283180
174111 NW FLANDERS ST
PORTLAND OR 97209 -- ---
Phone #: 620 -0868 $ 287.56 TOTAL
Reg #..: 084045
REQUIRED INSPECTIONS
This permit is issued subject to the regulations contained in the Footing Insp
Tigard Municipal Code, State of Ore. Specialty Codes and all other Foundation Insp
applicable laws. All work will be done in accordance with Slab Insp
approved plans. This permit will expire if work is not started Framing Insp
within 180 days of issuance, or if work is suspended for more Shear Wall Insp
than 180 days. Gyp Board Insp —
Final Inspection
/��
Permittee Signature: —
Issued By A. .. 44.46 -
-
/ Call for inspection -- 639 -4175
--
A. -- - - - - -
Commercial Building Permit Application
'City of Tigard
13125 SW Hall Blvd. G ____ F 5'
Tigard, OR 97223 ARBOR HEIGHTS APARTMENTS O:
(503) 639 -4171 r 1 (� L Address: : :.; :;.:,...:.:..;....�
ce Use 061V :.::..
enant�
to
T ,_
# `7 6 6.. l 5
Valuation: =- ► 6 •O
Planck/Rec
:Permit # : t?i.L _ t (; .;. `.
Owner: Securit Ca•ital Pacific T ust ' 1 .
TL # :�.. ::<; >' •
Address: 330 112th Ave. NE (1201 Approvals Required
Bellevue, Washington 98004 Plannin
Phone:
(206) 451-9292
Please direct and questions or correspondance to
owner's agent, the architect listed below. Other
Contractor:
Address:
Type V- 1 hour
Type of const:
Occupancy class: M>i- 1
Phone:
Sprinklered? Yes 1a .
Contractor's License #
(attach copy of current Oregon license) Sq. ft. of project `ICC TaTA L
Contact name & phone: Story (1st, 2nd, etc.) ) CO I P
Proposed use: Residential
Architect/Engineer: Riebe and Associates. Inc.
Previous use: None- new construction
Address: 2110 116th Ave. NE
Note: Plumbing & mechanical plans
Bellevue, Washington 98004 must be submitted at time of
building permit application.
Phone: (206) 451 -4084 (Contact Person: E. Dennis Riebe)
JOB DESCRIPTION: New Construction of Multifamily Residential Deve-1-14fteo. This building is
a par of a 348 unit apartment complex.
• 1 -
App!icant Signature & Phone number
4 1111-0 7-•: 2--/7-Vqb
a5
PERMIT # DESCRIPTION . CODE AMOUNT AMOUNT PAID BALANCE DUE
c
(Afgv tH Bldg Permit BUILD //‘ //6.50
P1mb Permit PLUMB
Mech Permit MECH
Elec Permit ELPRMT • ; • ;'
Ltd Energy Permit ELPRMT *�
State Tax
bldg tax subtotal 5
plmb tax subtotal
mech tax subtotal
ELC tax subtotal
ELR tax subtotal t1
ST TAX TOTAL A 5..g3
Plan Check Fees
(Req. for all) bldg plan chk BUPPLN 45.7
plmb plan chk PLMPLN
mech plan chk MECPLN
elect plan chk ELPLCK
(Req. w/ C) fire -life- safety chk FLS - y i 113 * 2v -- P-6. (o C)
PLAN CHK TOTAL
Sewer Connection
Permit SWUSA
Sewer Inspection SWINSP
Park Dev Charge PKSDC
TIF- Residential TIF -R
TIF -Mass Transit TIF -MT
TIF - Commercial TIF -C _
TIF - Industrial TIF -I
TIF- Institutional TIF -IS
TIF - Office TIF-0
TIF INFO
Water Quality WQUAL
Water Quantity WQUANT
Erosion Control
Permit ERPRMT z-6 D-6 • CO
Erosion Plan
Check - USA ERPLAN 4 _ LIS
Erosion Plan
Check - COT EROSN ok ly
. TOTAL 454, (os I (y7
•
Checked: � FEELISTh 9 141M-' Date: g/
Page No. 1 CASE HISTORY FOR CASE NO.: BUP96 -0241
SECURITY CAPITAL PACIFIC TRUST
15187 SW ROYALTY PKWY Unit: E
03/12/98
Action Description Req/ Schd/ End/ Action Notes Die') By Update Upd
Code Sent Done Done Date By
BUPA725 Framing Inep / / / / 03/04/97 PASS TLP 03/06/97 TLP
BUPB020 Plans Checked /Approved by P.E. 06/05/96 / / 06/05/96 JHF 06/05/96 JHF
BUPB025 Reviewed Plans Routed to DSTs 06/05/96 / / 06/05/96 APPR JHF 06/05/96 JHF
BUPB090 (F) Ready to issue / / / / 08/06/96 APPR JMH 08/06/96 J "H
BUPB100 (F) Issue permit / / / / 08/22/96 PASS CJS 08/22/96 CJS
BUPB100 (F) Issue permit / / / / 08/22/96 08/22/96 CJS
BUPB705 Footing Inap 06/05/96 / / 09/11/96 PASS TLP 10/09/96 TLP
BUPB706 Foundation Inep 06/05/96 / / 02/12/97 PASS TLP 02/13/97 TLP
BUPB715 Slab Inep 06/05/96 / / 02/21/97 PASS TLP 02/21/97 TLP
BUPB730 Framing Inap 06/05/96 / / 02/27/97 1. COMPLETELY DRYWALL JOISTS SPACES USED DIS GL 02/28/97 RB
FOR DUCT VUNS TO MAINTAIN 1 -HR
FLOOR /CEILING. 2. FIRE STOP FURRED
WALLS & PARTY WALLS AT 10 FT CENTRS.
3. FIRESTOP PLMG PENETRATIONS OF 1 -HR
FLOOR CEILING ASSEMBLY AS PER PLANS. 4.
FLOOR TO FLOOR HOLDOWN STRAPS ARE REQ'D
_., TO HAVE TRIPLE STUDS.
(DETAIL 20/55.2) 5. FINISH FIRE STOPPING
ALL ELECT. PENETRATIONS OF
1 -HR FLOOR /CEILING. 6. 200 LB.
HYDROSTATIC TEST REQD. FOR (CON'T.DOWN)
SPRINKLER SYSTEM. 7. ELECT APPROVAL OF
ALARM SYSTEM REQ'D. 8. ELECT
BOXES IN 1 -HR PARTY WALLS YO BE
SEPARATED A MIN 24" ON OPPOSING SIDES OR
BE COMPLETELY FIRESTOPPED BETWEEN THEM.
9. MPHHD HOLDOWNS APPEAR TO BE
MISSING FOR 7A WALLS -1ST FLR EAST END.
10. HOLDDOWN MISSING UNIT A -1
1ST FLOOR. 11. PLASTIC PLMG REQ'D TO
HAVE APPROVED MEMBRANE PENTRATION
FIRESTOPS AT ALL FIRE RESISTIVE
ASSEMBLIES. 12.WALL HEATERS IN CORRIDOR
WALLS EXCEED MAX. ALLOWABLE SIZE.
PROVIDE 5/8" ROCK AROUND THEM TO MAIN-
TAIN 1- HR (APT. SIDES) 13.VENT FAN &
RANGE DUCTS PENETRATING 1 -LTR
ROOF /CEILING. 14. INSTALL 1 -HR RATING
ATTIC ACCESS DOORS. (END NOTES)
BUPB750 Shear Wall Inap 06/05/96 / / 02/19/97 PASS TLP 02/19/97 TLP
BUPB760 Gyp Board Inep 06/05/96 / / 03/19/97 shear wall area PASS TLP 03/20/97 TLP
BUPB799 Final Inspection 06/05/96 / / 06/16/97 PASS TLP 07/11/97 JHF
BUPC960 Case Finaled / / / / 07/28/97 JT 07/28/97 JT
BUPD745 Insulation Insp / / / / 03/17/97 PASS TLP 03/17/97 TLP
BUPD760 Gyp Board Inep / / / / 03/27/97 PASS TLP 03/28/97 TLP