Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
MASTER PERMIT CITY OF T MAST PERMIT R # MS I "96-0083 .COMMUNITY DEVELOPMENT DEPARTMENT DATE ISSUED: 08 /c = /96 13126 SW HaII Blvd. Tigard, Oregon 97223.8199 (503) 639 -4171 PARCEL: 251 1 QiDB- 0020Ztt<I SITE ADDRESS...° 15055 SW ROYALTY PKWY MG • SUBDIVISION WILLOWBROOK FARM/ARBOR HEIGHTS ZONING: R -25 BLOCK LOT.. ....... :8 Remarks: BLDG G, 1 OF 14 MF UNITS • - -- - --- - -- - - - --- - BUILDING --- REISSUE: STORIES • 3 FLOOR AREAS BASEMENT...: 4034 sf REQUIRED SETBACKS - - -- REQUIRED CLASS OF WORK. :NEW HEIGHT • 0 FIRST 8068 sf GARAGE 0 sf LEFT : 0 SMOKE DETECTRS: Y TYPE OF USE...:MF FLOOR LOAD 0 SECOND...: 8068 sf FRONT • 0 PARKING SPACES: 0 TYPE OF CONST. :5 -1HR DWELLING UNITS: 28 FINBSMENT: 8068 sf RIGHT • 0 OCCUPANCY GRP.:R3 BDRM :70 BATH:56 TOTAL - - - - -: 24204 sf VALUE..$: 1769939 REAR • 0 -- - - - - -- PLUMBING SINKS • 0 WATER CLOSETS.: 0 WASHING MACH..: 0 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS 0 LAVATORIES 0 DISHWASHERS...: 0 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 0 CATCH BASINS..: 0 TUB /SHOWERS...: 0 GARBAGE DISP..: 0 WATER HEATERS.: 0 WATER LINE ft: 0 BCKFLW PREVNTR: 0 GREASE TRAPS..: 0 OTHER FIXTURES: 0 - - - -- MECHANICAL FUEL TYPES FURN (100K ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS : 56 CLOTHES DRYERS: 28 /ELE/ / / FURN )=100K ..: 0 UNIT HEATERS..: 0 HOODS : 28 OTHER UNITS...: 28 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS 0 W00DSTOVES 0 GAS OUTLETS...: 0 - - -- ----- - - ---- - ELECTRICAL - - - -- -- RESIDENTIAL UNIT - -- - -- SERVICE /FEEDER - -- - -TEMP SRVC /FEEDERS -- - -- BRANCH CIRCUITS - -- -- MISCELLANEOUS - -- - -ADD'L INSPECTIONS- - 1000 SF OR LESS: 0 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 0 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/0 SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT 0 MANF HM /SVC /FDR: 0 601 - 1000 amp.: 0 6 @1 +amps -1000 v: 0 MINOR LABEL -10: 0 1000+ amp /volt.: 0 — PLAN REVIEW SECTION - - - - -- Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) =225 A.: > 600 V NOMINAL: CLS AREA /SPC OCC: - - - - - -- -- ELECTRICAL - RESTRICTED ENERGY - -- A. SF RESIDENTIAL-------------- - - - - -- B. COMMERCIAL- AUDIO — & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /RAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: 0TH: .. BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: .. HVAC DATA /TELE COMM.: NURSE CALLS TOTAL * SYSTEMS: 0 Owner: ------------ - ----- Contractor: - — -- TOTAL FEES:$ 26350.75 SECURITY CAPITAL PACIFIC TRUST CONTRACTOR NOT ON FILE SUITE 201 330 112TH AVE., NE BELLEVUE WA 98004 Phone #: 206- 451 -9292 Phone #: Reg L. : This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. -- - - -_ -- — - - REQUIRED INSPECTIONS - - - - -- --------------- Post /Beam Mechan Wtr Proofing Bs■ Slab Insp Plumbing Top Out Firewall Insp Water Line Insp Mechanical Final Post /Beam Struct Electrical Servi Framing Insp Gyp Board Insp Water Service In Footing Insp Post /Beam Meehan Electrical Rough Roof Nailing Reinforced caner Appr /Sdwlk Insp Foundation Insp Crawl Drain Mechanical nsp Insulation Insp Engineered gradi Smoke Detector Erosion Control Ftg Drain Psi't G L'Dw t Shear Wall Insp Rain Drain In Additional Permi.ttee Signature: Issued By: Ak _ Call for inspection — 659- -4175 ITY OF TIGARD MASTER ' PERMIT PERMIT P ° MS'I "96- 0083 COMMUNITY DEVELOPMENT DEPARTMENT DATE ISSUED: 08/24/96 . 13125 SW Hall Blvd. Tigard, Oregon 97223.8199 (503) 639 -4171 PARCEL: 291 1 DDB- 00201Z' SITE ADDRESS...: 15055 SW ROYALTY PKWY #G SUBDIVISION • WILLOWBROOK FARM /ARBOR HEIGHTS ZONING: R-25 BLOCK • LOT -a Remarks: BLDG G, 1 OF 14 MF UNITS - - -- -- BUILDING REISSUE: STORIES : 3 FLOOR AREAS BASEMENT...: 4034 sf REQUIRED SETBACKS - -- REQUIRED - - - -- CLASS OF WORK.:NEW HEIGHT • 0 FIRST • 8068 sf GARAGE • 0 sf LEFT : 0 SMOKE DETECTRS: Y TYPE OF USE...:l'W FLOOR LOAD • 0 SECOND...: 8068 sf FRONT • 0 PARKING SPACES: 0 TYPE OF CONST.:5 -1HR DWELLING UNITS: 28 FINBSMENT: 8068 sf RIGHT : 0 OCCUPANCY GRP.:R3 BDRM:70 BATH :56 TOTAL - - -: 24204 sf VALUE..$: 1769939 REAR • 0 — - -- PLUMBING - - - -- --------------- - SINKS : 0 WATER CLOSETS.: 0 WASHING MACH..: 0 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS • 0 LAVATORIES • 0 DISHWASHERS...: 0 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 0 CATCH BASINS..: 0 TUB /SHOWERS...: 0 GARBAGE DISP..: 0 WATER HEATERS.: 0 WATER LINE ft: 0 BCKFLW PREVNTR: 0 GREASE TRAPS..: 0 OTHER FIXTURES: 0 ------ - - - - -- --- - - - - -- ---- ---- -- MECHANICAL FUEL TYPES-- - - - - -- FURN (100K ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS : 56 CLOTHES DRYERS: 28 /ELE/ / / FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS • 28 OTHER UNITS...: 28 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES....: 0 GAS OUTLETS...: @ - - - - - -- ------------------ - - - - -- ELECTRICAL -- RESIDENTIAL UNIT -- --- SERVICE /FEEDER -- - -TEMP SRVC /FEEDERS -- - -- BRANCH CIRCUITS - -- - -- MISCELLANEOUS - - -- - -ADD'L INSPECTIONS- - 1000 SF OR LESS: 0 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 0 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF HM /SVC /FDR: 0 601 - 1000 amp.: 0 601 +amps -1000 v: 0 MINOR LABEL -10: 0 1000+ amp /volt.: 0 - - - -- - - - - - -- PLAN REVIEW SECTION — Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC: - ----- -- ---- — ---- - ---- -------- - ----- ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL --- B. COMMERCIAL - - -- - -- - AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: 0TH: :: BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: :: HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0 Owner: ------------------- - - - - -- Contractor: TOTAL FEES:$ 26350.75 SECURITY CAPITAL PACIFIC TRUST DONALD M DRAKE CO SUITE 201 1740 NW FLANDERS ST 330 112TH AVE., NE BELLEVUE WA 98004 PORTLAND OR 97209 Phone #: 206 - 451 -9292 Phone #: 620 -0868 Reg #..: 084045 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. --------- - - ---- - - - -- - -- REQUIRED INSPECTIONS --- --- ---- -------- Post /Beam Mechan Wtr Proofing Bsm Slab Insp Plumbing Top Out Firewall Insp Water Line Insp Mechanical Final Post /Beam Struct Electrical Servi Framing Insp Gyp Board Insp Water Service In Footing Insp Post /Beam Mechan Electrical Rough Roof Nailing Reinforced concr Appr /Sdwlk Insp Foundation Insp Crawl Drain Mechanical Insp Insulation Insp Engineered gradi Smoke Detector Erosion Control Ftg Drain Bsm't Low Voltage Shear Wall Insp Rain Drain Insp Additional Perm _ ittee Signature: Q � On, ', Issued By: 11 4 , ' -.. /1 4.4 k.... /�, %/ 24 Call for inspection - 639 -4175 r t Commercial Building Permit Application - CIO of Tigard 1 13125 SW Hall Blvd. ARBOR HEIGHTS APARTMENTS BUILDING: 1 -1l Tigard, OR 97223 b ` (503) 639 -4171 Jobsite Address: 15055 SW ROYAL-TY PKWY 2- 68c. :.... . . ;.;.:....:..-.. ;. r...` :: .: =-' ....... < x:i -.:.r ':7:;sv aFst:•.:J,aS:YF '); : " -'• <..:. "'..- %^�' _ t °:. 'a''d M is - Zg uN .::.:: :;'.._,.:�:_ t . Tenant :.Of ice Use:O ; ,.: t.vi i��i /iti •`�.i$. 1r::y. {S :.,�..+:v:� Valuation: 1 , 7(o Q i X139 • OD k PlaciccJFtec #' >. ,...t .; . .3v +'r 4 Owner Security Capital Pacific Trust' F s. - 4v . . . }} :�;. `.:( ?T•� } }C:T!: • Address: 330 112th Ave. NE #201 <;::: : k: >r-: „ „= w>; >,'t:v;:: -. : ;> s< .:: Bellevue, Washington 98004 < . t : j . ( ; , » x4 = .ter.::.. ; ' }Ln.P.::.;.:,: \ \ - :� vim: \Yti :}4'- +5.,::,SHiW4: � vwt•4i♦';n�e� ” J• -T:Y':Nwf�,i�v.Q� v h1YM ': }.:•-:. '"?i } >•i.:.t: �....:aa.t 4. {:v:,'t. :3:'. 4t:Li - i' :.k.; N.� > Platia <.::......,:. .. :. v"':' 4.: v.. 1. � �' i �.}°. : >::;aa�.�..2�. :;�::.;:•i., Phone: (206) 451 -9292 Please direct and questions or correspondance to owner s agent, the architect listed below. ::Othec;` `�: : "::�:•: <A:,•: <.. . ....Y ... :.:•:.. ....'`: =`• } {s:::`: � } '.3'}::::.ti.:3,.q t ts.wgtti fi};. ":- w:�t2�:: }' t:. \�::.; � •.�T•: - :. ::.'... -.v.:£ •:a• �:at Contractor: - DONJA1,D DRAI6e co ' ' f `Y. '•:'+ ��O} vSa �Lir ti} v1nC3h�A�M: AY„ fi'.. �P.)Z1n:CtNJL:V{?+'.' Address: Type V- 1 hour Type of const • Occupancy class: R-1 Phone: Sprinklered? No • Contractor's License (attach copy of current Oregon license) Sq. ft of project Contact name & phone: P,LU Vitt! !tit J E 22-6 3991 Story (1st, 2nd, etc.) BASEMEIJT, PA-( 2 g 3 - 277S Proposed use: Residential Architect/Engineer: Riebe and Associates. Inc. Previous use: None - new construction Address: 2110 116th Ave. NE Note: Plumbing & mechanical plans Bellevue, Washington 98004 must be' submitted at time of building permit application. Phone: (206) 451 -4084 (Contact Person: E. Dennis Riebe) JOB DESCRIPTION: New Construction of Multifamily Residential Dwellings. This building is a part of a 348 unit apartment complex. C1 • 2 4C64• Applicant Signature & Phone number Received by: Date Received: �ZZ19b Page No. 1 CASE HISTORY FOR CASE NO.: MST96 -0083 SECURITY CAPITAL PACIFIC TRUST • 15055 SW ROYALTY PKWY Ubit: G 11/20/97 Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By • gOt 11G A MSTA026 Plans approved by Plans Exmr / / / / 04/01/96Y Of PASS MS 04/01/96 MRS CO MSTA080 (F) Ready to issue / / / / 08/06/96 APPR JMH 08/06/96 J *H MSTA711 Post /Beam Mechanical / / / / / / SI 03/10/96 J *H MSTA795 Mechanical Final / / / / / / 03/10/96 J *H MSTB005 Application received / / / / 02/21/96 gt1tl 9 05/03/96 BT2 MSTB008 Permit created • / / / / 05/03/96 � 05/03/96 BT2 MSTB010 Check for prcl. restrict. / / / / / / ostC 03/10/96 J *H MSTB012 Plans routed to Plans Examiner / / / / / / 03/10/96 J *H MSTB026 Plans approved by. Plans Exmr / / / / 03/20/96 PASS MJR 03/20/96 MJR MSTB026 Plane approved by Plans Exmr 05/03/96 / / 06/04/96 JHF 06/05/96 JHF MSTB030 Reviewed plans routed to DSTS •/ / / / 03/20/96 letter attached YES MJR 03/20/96 MJR MSTB030 Reviewed plans routed to DSTS 05/03/96 / / 06/04/96 hold for receipt of epl inp forms [2] APPR JHF 06/05/96 JHF MSTB065 Hold for Pre -Job Coif / / / / / / 03/10/96 J *H MSTB098 (F) Issue combination permit / / / / 08/22/96 PAID JMH 08/22/96 J *H MSTB105 (F) Reprint Permit / / / / 08/24/96 OOPS JMH 08/24/96 J *H MSTB410 Devel review cond. met /. / / / / / 03/10/96 J *H MSTB705 Footing Insp / / / / 01/02/97 spot footings require eng. of job to PART TLP 01/24/97 TLP inspect they appear questionable as they have been installed - MSTB706 Foundation Inep / / / / / / . 03/10/96 J *H MSTB708 Erosion Control / / / / / / 03/10/96 J *H MSTB709 Wtr Proofing Bem't Walls / / / / / / 03/10/96 J *H MSTB710 Post /Beam Structural / / / / 01/02/97 ok when spot footings approved PART TLP 01/24/97 TLP MSTB711 Poet /Beam Mechanical • / •/ / / / / • 03/10/96 J *H MSTB713,Crawl Drain / / / / / / • 03/10/96 J *H MSTB714 Ftg Drain Bem't Walls / / / / / / 08/14/96 J *H MSTB715 Slab Insp / / / / 10/14/96 • PASS TLP 11/06/96 TLP MSTB723'Electrical Service / / / / / / 08/14/96 J *H MSTB724 Electrical Rough -in / / / / 05/14/97 Telephone cables need physical PASS MJR 05/22/97 J *H protection and fire blocking. Telephone cables cannot cross attic . entrance. * *THE TELEPHONE TO CALL FOR REINSPECTION IS 639- 4175. ** Electrical rough -in and service approved. , Question for IAEI - loop in pool cond. MSTB725 Mechanical Insp / / / / / / 03/10/96 J *H MSTB727 Low Voltage / / / / / / 08/14/96 J *H MSTB729 Plumbing Top Out • / / / / / / 08/14/96 J *H MSTB730 Framing Insp / / / / 05/15/97 PASS TLP 05/28/97 TLP MSTB737 Roof Nailing / / / / / / . 08/14/96 J *H i . Page No. 2 CASE HISTORY FOR CASE NO.: MST96 -0083 SECURITY CAPITAL PACIFIC TRUST 15055 SW ROYALTY PKWY Unit: G 11/20/97 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MSTB745 insulation Inap / / / / / / 03/10/96 J *H MSTB750 Shear Wall Inap / / / / 05/02/97 PASS TLP 05/05/97 TLP MSTB755 Firewall Insp / / / / / / 03/10/96 J *H MSTB760 Gyp Board insp / / / / 05/28/97 nailing passed PASS TLP 05/30/97 J *H MSTB761 Reinforced concrete final rept / / / / / / 08/14/96 J *H MSTB772 Engineered grading final reprt / / / / / / 08/14/96 J *H MSTB779 Rain Drain Insp / / / / 10/14/96 PASS TLP 11/06/96 TLP MSTB780 Water Line Insp / / / / / / 08/14/96 J *H MSTB781 Water Service Inap / / / / / / 08/14/96 J *H MSTB785 Appr /Sdwlk Inap / / / / • / / 08/14/96 J *H MSTB789 Smoke Detector / / / / / / 03/10/96 J *H MSTB790 Fire Alarm Insp / / / / 08/11/97 see bup97 -0101 PASS TLP 08/11/97 J *H MSTB796 Electrical Final / / / / 08/06/97 PASS•BRP 08/07/97 B *P MSTB797 Plumb Final / / / / 08/07/97 PASS RAB 08/08/97 RAS MSTB798 Mechanical Final / / / / 08/11/97 PASS TLP 08/11/97 J *H MSTB799 Building Final / / / / 08/11/97 11/7/97 FROM BRIAN. OK TO RELEASE PASS TLP'11 /20/97 JT \ 11/ 97 TO JILL FOR C/O APPROVAL MSTDOSO Hold for / / / / 08/12/97 this should have been disapproved HOLD JT 08/12/97 JT pending land use case finaled. as of this date, engineering has not released • C/O for bldg. G MSTD095 issue plumbing signature form / / / / 04/23/97 RECD JT 08/12/97 JT MSTD097 Issue Electric Signature Form / / / / 04/28/97 RECD JT 08/12/97 JT • • SD/2._.q5 -U° 1 CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection Line: 639-4175 Business Phone: 639 -4171 Date Requested: it l ` A.M. P.M. MST: / �� 8'3 Location: I (S—U S L¢ ' BUP: q-7 go/ Tenant: Suite: Bldg: tr MEC: Contractor: n`- T<D Phone: CO 2-0 0 g6 p iPL`16IA, %- 0 -36 Owner: Phone: ELC: �}.(,9t.R,C.Q/� ELR: "� SIT: B I 0 ING ..: LDG co ..7_, PLUMBING MEC ELECTRICAL SITE Site Post/Beam Post/Beam esu> Cover /Service Sewer /Storm Footing Roof UndFl/Slab Rough -In Ceiling Water Line Slab Framing Top Out Gas Line Rough -In UG Sprinkler Foundation Insulation Sewer Hood/Duct Reconnect Vault Bsmt Damp Drywall Storm Furnace Temp Service MISC. Masonry - Rain Drain A/C UG Slab Shear /Sheath ` L S . kir 4 •y1 Crawl/Found Dr H- : . II . Low Volt � Approved • y•roved Approved Approved Appr /Sdwlk Not • . • ov -. Not Approved 1�...R • • :. ppr .. Not Approved Not Approved • 1` 1 / FINAL ic FINAL FINAL FINAL ae) 7 0 e to cyy C6 • �`c�, c- a Call for r . = 0 Re inspection fee of $ req ' bef re next inspection 0 Unable to inspect 4 0 Inspector: ar- Date: C9 4 P Page of CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171 Date Requested: O 1,1 I A.M. P.M. MST: 76 Q Q O 3 Location: ) S v SS P4 BUP: Tenant: Suite: Bldg: MEC: Contractor: Pt-7--- Phone: d q q, PLM: Owner: Phone: ELC: ELR: SIT: BUILDING BLDG (con't) PLUMBING MECHANICAL ELECTRICAL SITE Site Post/Beam Post/Beam Post/Beam Cover /Service Sewer /Storm Footing Roof UndFl/Slab Rough -In Ceiling Water Line Slab Framing Top Out Gas Line Rough -In UG Sprinkler Foundation Insulation Sewer Hood/Duct Reconnect Vault Bsmt Damp Drywall Storm Furnace Temp Service MISC. Masonry Ceiling Rain Drain A/C UG Slab Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Volt Approved oved � _ Approved Approved Approved Appr /Sdwlk Not Approved of A proved Not Approved Not Approved Not Approved FINAL F IN FINAL FINAL FINAL O Call for ,- r .. ; ■ O O Reinspec 'n f- of $ required before next inspection 0 Unable to inspect 7 AND /// Inspector: tab �� „a - , _ �� . i � 4_, Date: '/ Z I Page of 4011110” j r i i z g . # CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171 Date Requested: B l (0 1 MST: Cp 00 p e9 A.M. A M P.M. MST. 0 3 Location: 1 5 S5 BUP: Tenant: Suite: Bldg: (-. MEC: Contractor: t3 � aJ 1 C J Phone: $ o - ; �. 3 D PLM: Owner: Phone: ELC: ELR: SIT: BUILDING BLDG (con't) PLUMBING MECHANICAL ,ELECTRICAL SITE Site Post/Beam Post/Beam Post/Beam Cover /Service Sewer /Storm Footing Roof UndFl/Slab Rough -In Ceiling Water Line Slab Framing Top Out Gas Line Rough -In UG Sprinkler Foundation Insulation Sewer Hood/Duct Reconnect Vault Bsmt Damp Drywall Storm Furnace Temp Service MISC. Masonry Ceiling Rain Drain A/C UG Slab Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Volt Approved Approved Approved Approved Approved Appr /Sdwlk Not Approved Not Approved Not Approved '0 : • • oved Not Approved FINAL FINAL FINAL 311 FINAL • • TD O Call for reinspection Reinspection fee of $ required before next inspection O Unable to inspect Inspector: Date: 6 Y — C 2 Page of